A. The entire Local Planning Area is conceptually organized into three main
CATEGORIES
RESIDENTIAL
(R)
COMMERCIAL
(C)
ii. Areas coming between the Core Ring road and the Outer Ring Road: Ring II
INDUSTRIAL
(I)
iii. Areas coming beyond the Outer Ring Road and within the LPA: Ring III
(P&SP)
(T&T)
PUBLIC UTILITIES
(PU)
(P)
UNCLASSIFIED
(UC)
AGRICULTURE LAND
(AG)
iv. The above rings are equivalent to Zone-A, Zone-B and Zone-C for TDR
Purposes
Ground coverage:
The total area covered by building immediately above the plinth level. Swimming pool, sump tank, pump house and electric
substation, utilities are not included.
Basement:
i. Means storey which is partly or wholly below the average ground level and with a height not exceeding a projection of 1.2 m
above the average ground level and overall height of the basement under any circumstances should not exceed 4.5 m between the
floor and the ceiling of the basement in case of normal parking. In case of stacked/ mechanical parking the height of the basement
may be permitted up to a maximum of 4.5m
ii. If a site is measuring less than 200sqm, then car parking shall not be permitted in the basement floor.
iii. If the minimum setback is more than 2.0 m, then the basement may be extended on all sides except the side abutting the road,
provided the minimum setback between the basement and property boundary is minimum 2.0 m.
iv. Basement floors up to a maximum of 5 (five) levels may be permitted for car parking.
v. Permissible uses in the Basement for buildings other than 3 star and above category:
Dark rooms for X ray and storage of light sensitive materials
Bank Safes/ Strong room included in the FAR
Air condition handling units/equipment, utilities and services connected with the building.
Parking
Projections:
i. Projection into open spaces: Every open spaces provided either interior or exterior shall be kept free from any erection there on and
shall be open to the sky and no cornice roof or weather shade more than 0.75 m wide or 1/3 rd of open space/setback which ever is
less shall overhang or project over the said open space.
ii. No projection shall over hang/project over the minimum setback area either in cellar floor or at the lower level of ground floor.
iii. Cantilever Portico of 3.0 m width (maximum) and 4.50 m length (maximum) may be permitted within the side setback. No access
is permitted to the top of the portico to use it as a sit out place and the height of the portico shall be not be less than 2.00 m from
the plinth level. The portico is allowed only on the side where the setback/open space left exceeds 3.00 m width.
iv. Balcony: Balcony projection should not exceed 1/3 rd of the setback on that side subject to a maximum of 1.10m in the first floor
and 1.75 m beyond the second floor. No balcony is allowed in the ground floor.
2. NOTES
a) Setbacks shall be in accordance with Table.8 or Table.9 depending on the height of proposed building and the plot size.
b) If the road width is less than 9.0 m, then the maximum height is restricted to 11.5 meters or Stilt +GF+2 floors (whichever is
less) irrespective of the FAR permissible
c) Multi dwelling units (Apartments) shall be allowed only on plot sizes of above 360 sq.m in the I and II Ring and on plots above
750 sq.m in the III Ring. In both cases, the road width shall be more than 9.0m.
d) TDR is applicable as per rules.
2. PARKING
a) Buildings with a floor area not exceeding 100
sqm are exempted from providing car parking.
However, equivalent parking fee shall be levied as
determined by the authority from time to time.
This is applicable only for areas coming within I
Ring.
2. PARKING
i. Buildings with a floor area not exceeding 100sqm are exempted from providing car parking. However, equivalent parking fee shall
be levied as determined by the authority from time to time. Parking fee shall be credited to a separate head of account and it shall be
used for providing parking facilities.
Notes
a) TDR is applicable as per rules.
b) Setbacks shall be in accordance with Table-8 or Table-9
depending on the height of the proposed building and the
plot size.
the table for the surrounding zone that it passes through e.g.
permissible
If the plot size is more than 240 sq.m and faces a road width
(Main) Zone.
Notes:
a) After leaving minimum setbacks as per the above table if the remaining portion of the plot cannot be used for erecting a
meaningful building, the Authority may insist for set backs as in table.8 or table.9
b) All lands/sites allotted by government agencies like KIADB, KSIIDC etc, for industrial use shall not be permitted to be utilised
for any other use, without the NOC from such departments/ agencies as case may be.
c) TDR is applicable as per rules.
REGULATIONS FOR MAIN LAND USE ZONES:Public and Semi Public (P&SP)
This zone includes Government owned complexes and civic amenities and large infrastructure facilities of health, education, sports, cultural and
social institutions.
educational,
cultural
and
religious
Note:
i. When Multi Level Car Parking (MLCP) is proposed on a plot as independent activity, there shall not be any limitation of FAR or
height of building subject to condition that it satisfies fire and airport authority restrictions where ever applicable.
ii. TDR is applicable as per rules.
Notes:
1. The buffer created for accommodating the utilities such as Power, Water Pipeline, Oil pipelines, and High Voltage lines,
gas lines and any other utilities. Each buffer is dictated by technical standards specified by the competent authority.
2. The regulations for the above will be decided by the Authority.
3. In case of new developments, these shall remain as non buildable areas and remain as reservations and marked for the
purpose intended. They may be considered for calculation of open spaces within the schemes while approving
building/development and layout plans.
4. For electrical networks, KPTCL standards are followed.
REGULATIONS FOR MAIN LAND USE ZONES: Park and Open Space (P)
The natural and man made features meant for environmental conservation and preservation, including water bodies, forests and drains; parks,
playgrounds, burial grounds and crematoria.
2. VALLEY / DRAIN
Uses
permissible
include:
Sports
grounds,
Within the demarcated buffer for the valley the following uses are
allowed:
i. Sewerage Treatment Plants and Water treatment plants
ii. Roads, pathways, formation of drains, culverts, bridges, etc which
will not obstruct the water course, run offs, channels.
iii. In case of water bodies a 30.0 m buffer of no development zone
is to be maintained around the lake (as per revenue records) with
exception of activities associated with lake and this buffer may be
taken into account for reservation of park while sanctioning plans.
iv. If the valley portion is a part of the layout/ development plan,
then that part of the valley zone could be taken into account for
reservation of parks and open spaces both in development plan and
under subdivision regulations subject to fulfilling section 17 of
KTCP Act, 1961 and sec 32 of BDA Act, 1976.
v. Any land falling within the valley for which permission has been
accorded either by the Authority or Government, and then such
permission shall be valid irrespective of the land use classification in
the RMP 2015. Fresh permissions for developments shall not
be accorded in valley zone.
2. COVERAGE
20 % of the sital area of the land may be used for
educational and health purposes and a building height of
G+1 floor only shall be permitted.
For Golf courses on land area which is above 40 ha,
ancillary uses can be permitted up to a maximum of 20 %
major roads.
houses and accessory not exceeding 250 sq.m of plinth area within
the plot area limitation of 1.2 Ha limited to G+ 1 floor.
Clubs, cultural buildings, exhibition centres, storage and sale of
farm products.
Service and repairs of farm machinery.
Piggeries and poultry farms, livestock rearing.
Brick Kilns.
When the land is more than 40.0 ha in extent, Golf course along
with ancillary uses like administrative office, guest rooms/guest
houses and dining facilities are permissible.
(ii) In case, any private property is included within the boundary of unclassified and if the owner can establishes that the
ownership of land vests with him/her, the land use adjoining the land shall be assigned to the land in question (to be
decided by the Authority Only )
SUBDIVISION REGULATIONS
a. Road widths: The minimum width of road shall not be less than 9.0 m and the road widths shall not be less than the plot widths
facing the respective road. Every Fourth road in a layout shall have a minimum of 12.0 m width.
b. Area for Residential development: Apart from the provision for amenities and open spaces, the area for residential development
shall be up to a maximum of 55 % of the total land area.
c) Parks / Open spaces and Playgrounds: Parks / Open spaces and Playgrounds shall not be less than 15 % of the total land area.
d) Civic amenities and Roads:
i) After making provision for Parks and roads in the layout, the balance portion of land shall be earmarked for civic amenity site
only. Such CA site shall be relinquished to BDA free of cost and free of encumbrance.
ii) If the area that remains after making provision for road and park is less in extent, then the authority shall have the discretion to
earmark such land for park.
iii) When ever the total area proposed for formation of layout exceeds 10 acres, then adequate extent of land may be earmarked for
provision/installation of utilities like transformer, sewage treatment plant, overhead water tank, bus bay/shelter etc.
iv) CA sites owned by Bangalore Development Authority (BDA) could be used for any purpose irrespective of the land use
classification in the Revised Master Plan-2015.
Exemptions:
On request from the land owner, reservations for Parks and Civic Amenities as per subdivision regulations may be dispensed with
by collecting the guideline value of equivalent converted land, in case the land is less than 4,000 sq.m
In case of residential layouts proposed for development by individuals wherein the extent of land is more than 10.0 ha, commercial
uses up to 3 % of total land may be permitted within the permissible percentage of 55 % in one or two blocks only
SUBDIVISION REGULATIONS
General conditions applicable for sub division, amalgamation and Bifurcation of plot:
i. Subdivision
The Authority reserves the right to modify the layout submitted by the applicant / owner and may impose any condition either
from planning point of view or in the interest of public.
60 % of the sites shall be released upon issue of work order based on the draft plan. The sites to be released are to be clearly
indicated on the plan along with the phase wise development. The release of sites is subject to relinquishment of civic amenity sites
/ parks & open spaces and roads to the authority free of cost by way of a registered relinquishment deed. 40 % of the sites shall be
released only after the layout is fully developed in terms of utilities and infrastructure. The entire process shall be as per the
government order issued in this regard.
The approval of Layout Plan is subject to the condition that the proposal satisfies all the requirements stipulated under section 17
of K.T.C.P Act, 1961 and section 32 of BDA Act, 1976.
ii. Amalgamation
In the case of amalgamation, the proposed sites shall have the same land use.
Ownership of the amalgamated plot could be in single or multiple names/family members/ company. But, amalgamation shall
not be considered if the plots are under lease agreement.
Development controls for the amalgamated plot shall be with reference to new dimensions.
iii. Bifurcation;
In the case of all bifurcations, whether corner site or intermediate site, front setback for the resulting site abutting the road shall
be the same as that of the original site and not that of the subdivided site.
A Plot/ Site which is a part of the sub division plan/layout/scheme duly approved by the authority maybe further bifurcated
with prior permission of Authority and the sub divided plot shall not be less than the prescribed size.
Bifurcated plot shall not be less than 50 sq mt. Bifurcated plot shall have a minimum of 3.0 m access.
The bifurcated plot shall have a minimum of 6.0 m frontage.
ship
i. 10% of the total area shall be reserved for parks & open space.
the vibrancy and dynamism of the urban form for a city like
ii. 5% of the site area shall be reserved for public & semi-public
Bangalore.
for CA.
zones
Exits.- Every building meant for human occupancy shall be provided with exits sufficient to permit safe escape of its occupants in
case of fire or other emergency for which the exits shall conform to the following:
i. Types. Exits should be horizontal or vertical. A horizontal exit may be a door-way, a corridor, a passage-way to an internal
stairway or to an adjoining building, a ramp, a verandah, or a terrace which has access to the street or to the roof of a building. A
vertical exit may be a staircase or a ramp, but not a lift.
ii. General requirement Exits from all the parts of the building, except those not accessible for general public use, shalla.
provide continuous egress to the exterior of the building or to an exterior open space leading to the street;
b. be so arranged that, except in a residential building, they can be reached without having to cross another occupied unit;
c. be free of obstruction;
d. be adequately illuminated;
e. be clearly visible, with the routes reaching them clearly marked and signs posted to guide any person to the floor concerned;
f. be fitted, if necessary, with fire fighting equipment suitably located but not as to obstruct the passage, clearly marked and with its
location clearly indicated on both sides of the exit way;
g. be fitted with a fire alarm device, if it is either a multi-storeyed, high use or a special building so as to ensure its prompt
evacuation;
h. remain unaffected by any alteration of any part of the building so far as their number, width, capacity and protection thereof is
concerned;