Conversion Table & Formulas Technical Data

This document provides conversion tables and formulas for technical HVAC data. The tables list common HVAC units of measurement and the multiplication factors to convert between them, such as CFM to liters per second, BTU/HR to Watts, inches to millimeters, and pounds to kilograms. Useful formulas are also provided for evaporative cooling calculations, including formulas to calculate saturation efficiency, temperature reduction, and cooling effect in kilowatts.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
44 views2 pages

Conversion Table & Formulas Technical Data

This document provides conversion tables and formulas for technical HVAC data. The tables list common HVAC units of measurement and the multiplication factors to convert between them, such as CFM to liters per second, BTU/HR to Watts, inches to millimeters, and pounds to kilograms. Useful formulas are also provided for evaporative cooling calculations, including formulas to calculate saturation efficiency, temperature reduction, and cooling effect in kilowatts.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Conversion Table & Formulas

Technical Data

CONVERSION TABLE
& FORMULAS
To
Convert

Into

Multiply
by

To
Convert

Into

Multiply
by

CFM
CFM
FPM
BTU/HR
BTU/HR
Lbs
Gallons
HP
Inches
Feet
FT2
FT3
P.S.I
Ins of H20

L/second
M3hr
M/Sec
Watts
Mj
Kg
Litres
kW
MM
Meters
M2
M3
kPa
Pa

.475
1.698
.00508
.2932
.001055
.4536
4.546
.7457
25.4
.3048
.0929
.0283
6.895
250

L/second
M3hr
M/Sec
Watts
Mj
Kg
Litres
kW
MM
Meters
M2
M3
kPa
Pa

CFM
CFM
FPM
BTU/HR
BTU/HR
Lbs
Gallons
HP
Inches
Feet
Ft2
Ft3
P.S.I
Ins of H20

2.118
.588
196.85
3.41
947.867
2.2046
.22
1.341
0.394
3.28
10.76
35.55
.145
.004

USEFUL FORMULA FOR


EVAPORATIVE COOLING:
e

T=

ti - tr
x 100%
ti - twi
e (ti - twi)
100

= 1.23 x qv
e (ti - twi) + tr - ti
1000 100

= cooling effect in Kilowatts

qv = air flow of cooler in L/sec


e
ti
twi
tr

= saturation efficiency %
= inlet dry bulb temp C
= inlet wet bulb temp C
= outlet dry bulb temp C

T = temp. reduction from cooler


One ton of refrigeration = 12000BTU/Hr or 3.517 kW/hr
Fahrenheit to Celsius cC = 0.55 (0F-32)
Celsius to Fahrenheit 0F = (1.8 x 0C) +32

It is the policy of Seeley International to introduce continual product improvement. Accordingly, specifications are subject to