Building Design 2 Drainage Notes
Building Design 2 Drainage Notes
SYSTEM OF DISPOSING OF
SEWAGE OF A BUILDING
TYPES OF WASTEWATER
1. DOMESTIC WASTEWATER
PRIMARILY SPENT WATER FROM
BUILDING WATER SUPPLY.
2. STORM WATER WATER
THAT RUNS OFF THE ROOF.
3. INDUSTRIAL WASTEWATER
WASTEWATER COMING FROM
INDUSTRIES WHICH REQUIRES
TREATMENTS TO REMOVE
SPECIFIC ELEMENTS INJECTED BY
INDUSTRIAL PROCESSES.
TYPES OF SEWAGE DISPOSAL
SYSTEM
1. PUBLIC SEWER LINE PUBLIC
SEWAGE DISPOSAL SYSTEM
CONSISTING
OF
SEWAGE
TRATMENT UNIT (CONVEYS
RAW SEWAGE TO DISPOSAL
SYSTEM)
2. SEPTIC TANK
SEWER CONDUIT FOR WATER
CARRIAGE OF WASTES
SEWERAGE SYSTEM OF
SEWERS AND APPURTENANCES
TWO TYPES OF SANITARY
SEWER SYSTEM
1. INTERCEPTING/TRUNK LINE
SEWER
2. TRIBUTARY/CONTRIBUTING
SEWER
DRAINAGE
SYSTEM
SUBDIVIDED
INTO
THREE
COMPONENTS
(DRAINAGE,
WASTE, VENT)
GENERAL REQUIREMENTS
1. PIPES MUST BE FITTED AND
TIGHTLY
CONNECTED
(TO
PREVENT LIQUID OR GAS
LEAKAGE).
2. VENTILATION MUST CONVEY
GASES
TO
ATMOSPHERE
(WHERE IT NO HARM HUMAN
HEALTH).
WATER SEAL)
B. DEEP SEAL TRAP HAS 7.510CM WATER SEAL CONTENT.
* FOR EXTREME HEAT
CONDITION, INC/DEC
ATMOSPHERIC PRESSURE,
TOTAL VENTILATION IS
UNOBTAINABLE. (GREATER
RESEALING QUALITY).
2. DRUM TRAP LARGE IN
DIAMETER, USED FOR FIXTURES
SET ON THE FLOOR (BATH TUBS).
USED FOR FIXTURES THAT
DISCHARGES
SUSTANTIAL
AMOUNT OF WATER WHEREIN
TRAP SEAL LOSS IS MORE
PREVALENT.
OTHER TRAPS
1. GREASE TRAPS DESIGNED
TO INTERCEPT GREASES AND
SOLIDS BEFORE THEY ENTER
WASTEWATER
DISPOSAL
SYSTEM. (KITCHEN, HOTELS,
CLUBHOUSES, RESTAURANTS).
SOLID FOOD PARTICLES SINK TO
THE BOTTOM, OIL FLOATS.
2. GARAGE GREASE TRAPS
DESIGNED TO RECEIVE WASTE
FROM GARAGE WASH RACKS,
GREASE PITS, AND REPAIR
FLOORS THEN CONVEYS INTO
THE HOUSE DRAIN.
3. HOUSE TRAPS DEVICE
INSTALLED IN A HOUSE DRAIN
THAT ACTS AS BARRIER TO
PREVENT GASSES FROM SEPTIC
TANK OR SERWER LINE.
4. CATCH BASIN
MAINTAINS
A
BALANCED
ATMOSPHERIC PRESSURE INSIDE
PIPES.
MAIN FUNCTION OF VENT PIPES
1. PREVENT LOSS OF TRAP SEAL.
2. PREVENT RETARDATION OF
FLOW OF LIQUIDS.
3. PREVENT DETERIORATION OF
PIPES.
CAUSE OF TRAP SEAL
1. SIPHONAGE
A. DIRECT SELF-SIPHONAGE
B. INDIRECT/MOMENTUM
SIPHONAGE.
2. BACK PRESSURE
3. EVAPORATION
4. CAPILLARY ACTION
KINDS OF VENTILATION
1. MAIN SOIL & WASTE VENT
BACKBONE OF ENTIRE SANITARY
SYSTEM. PORTION WHERE
WASTE DOES NOT TRAVEL THRU
2. MAIN VENT PRINCIPAL
ARTERY OF VENTING SYSTEM.
COLLECTING
VENT
LINE.
SUPPORT TO THE MS&WV (#1).
3. INDIVIDUAL/BACK VENT
PIPE INSTALLED TO VENTA
FIXTURE TRAP THAT CONNECTS
WITH VENT SYSTEM ABOVE
FIXTURE
SERVED
OR
TERMINATES IN THE OPEN AIR.
4. UNIT/COMMON/DUAL VENT
ARRANGEMENT OF VENTING
SO INSTALLED THAT ONE VENT
PIPE SERVE TWO TRAPS.
5. RELIEF VENT VERTICAL VENT
LINE
THAT
PROVIDES
ADDITIONAL CIRCULATION OF
AIR.
6. YOKE/BY-PASS VENT PIPE
CONNECTING UPWARD FROM A
SOIL/WASTE STACK BELOW
FLOOR TO AN ADJACENT STACK.
7. CIRCUIT VENT BATTERY OF
FIXTURES
8. LOOPED VENT VERTICAL
VENT CONNECTION ON HORI
SOIL/WASTE PIPE BRANCH AT A
POINT DOWNSTREAM.