AccuLoad III Specifications
AccuLoad III Specifications
MEASUREMENT SOLUTIONS
AccuLoad III-Q
Hardware
FEATURES
Up to three single or dual pulse product meter
inputs (S)
Up to six single or dual pulse product meter
inputs (Q)
Up to six products for ratio or sequential
blending
Up to 24 additive meter inputs
Auto-detection of hardware installed
Up to six-arm operation (Q); 2-arm operation (S)
Each arm programmable for straight product,
sequential blending, ratio blending, or side
stream blending
Up to 50 recipes
User-configurable inputs and outputs
Block valve control and feedback
(sequential blending)
Explosion-proof
Programmable language/messages
Network printing
Applications
Standard Features
The AccuLoad loading arm functions are individually programmable providing flexibility for how each arm can be
configured. The following charts and descriptions define
the types of loading including straight product and various
styles of blending. The AccuLoad III-S hardware has three
product meters that can be used among two load arms
while the AccuLoad III-Q hardware has six product meters
available to be used among six load arms.
Arm 2
STR/SEQ
STR/SEQ
N/A
AccuLoad-Q Hardware
Arm 1
Arm 2
Arm 3
Arm 4
Arm 5
Arm 6
STR/SEQ
STR/SEQ
STR/SEQ
STR/SEQ
STR/SEQ
STR/SEQ
2 Prod RAT
STR/SEQ
STR/SEQ
STR/SEQ
STR/SEQ
N/A
2 Prod RAT
2 Prod RAT
STR/SEQ
STR/SEQ
N/A
N/A
2 Prod RAT
2 Prod RAT
2 Prod RAT
N/A
N/A
N/A
3 Prod RAT
STR/SEQ
STR/SEQ
STR/SEQ
N/A
N/A
3 Prod RAT
2 Prod RAT
STR/SEQ
N/A
N/A
N/A
3 Prod RAT
3 Prod RAT
N/A
N/A
N/A
N/A
4 Prod RAT
STR/SEQ
STR/SEQ
N/A
N/A
N/A
4 Prod RAT
2 Prod RAT
N/A
N/A
N/A
N/A
5 Prod RAT
STR/SEQ
N/A
N/A
N/A
N/A
6 Prod RAT
N/A
N/A
N/A
N/A
N/A
Straight Product
The AccuLoad III is designed to handle loading of straight
products. All products can be loaded simultaneously.
Sequential Blending
The AccuLoad III is designed to sequentially control the
loading of up to six petroleum or chemical products
through each loading arm. All loading arms can be loaded
simultaneously.
Ratio Blending
The AccuLoad III-Q is designed to control the blending of
up to six petroleum products and the AccuLoad III-S up to
three products through a single loading arm. All products
flow through a metering system, are co-mingled downstream of the metering system, and flow through a single
loading arm into a transport or into storage.
Hardware Options
AccuLoad Interface Control Board
The AccuLoad Interface Control Board provides additional
flexibility to the AccuLoads standard features. The
optional AICB Board provides either ten additional
metered additive injector systems or twenty additional
programmable outputs. With the optional AICB Board,
the AccuLoad III with firmware has the capability of
handling up to fourteen metered injectors, fourteen meter
inputs, fourteen solenoid valve outputs, and fourteen
additive pump outputs. Adding two AICB Boards provides
the capability of this unit to handle up to twenty-four
4
Accuracy
Calculated Accuracy: The gross at standard temperature to gross volume ratio, excluding the accuracy of
fluid temperature measurement, will exactly match the
proper volume correction factor of ASTM-D-1250-04
over the fluid temperature range of -58F to 302F
(-50C to 150C).
Temperature Measurement Accuracy: Fluid temperature is measured to within 0.72F (0.4C) over the
fluid temperature range of -328F to 572F (-200C
to 300C). Fluid temperature is measured to within
0.45F (0.25C) over the fluid temperature range
of 32F to 572F (0C to 300C).
Electrical Inputs
AC Instrument Power:
Universal input 100 to 240 Vac, 58W maximum,
48 to 63 Hz. The AC circuitry is fuse-protected.
AC Inputs:
Type: Optically-isolated, solid-state voltage sensor.
DC Inputs:
Type: Optically-isolated solid state voltage sensors
Temperature Probe:
Type: four-wire, 100 Platinum Resistance
Temperature Detector (PRTD).
Keypad:
Type: Metal encapsulated, one-piece, sealed, no
moving parts, piezoelectric design. Protected against
the environment.
Display:
The Graphics Display is a 240 by 64 pixel graphic Liquid
Crystal Display (LCD) modules with LED backlighting.
Electrical Outputs
DC Power:
24 Vdc 10%, 1 A maximum, short circuit protected.
AC Outputs:
Type: Optically-isolated, AC, solid-state relays.
User-programmable as to function.
DC Outputs:
Type: Optically-isolated solid state output.
User-programmable as to function.
Note: When used, these outputs use the DC output points on the
KDC (DC output 1-3 respectively and also the 3 digital inputs 1-3
respectively).
Environment
Humidity:
5 to 95% with condensation.
Approvals
Enclosure:
Explosion-proof (NEMA 7, Class I, Groups C and D) and
watertight (NEMA 4X), IP65.
UL/CUL
Class I, Division 1, Groups C & D; Class II, Groups E, F &
G, UNL-UL Enclosure 4X, CNL-CSA Enclosure 4.
ATEX / IEC Ex
DEMKO 02 ATEX 130951X
IEC Ex UL 11.0018X
Ex d IIB T6 Gb IP 65 Tamb = -40C to +60C.
InMetro
No. 0025
Electromagnetic Compatibility
Electromagnetic Emissions:
IEC/EN 61000-6-3: Generic Standards - Emission
standard for residential, commercial, and light-industrial
environments
IEC/EN 55022: ITE - Radio Disturbance Characteristics Limits and Methods of Measurement
Electromagnetic Immunity:
Communications
DC Instrument Power:
24 Vdc 10%, 1 watt maximum
Pulse Input:
Type: High-speed, edge-triggered, optically isolated,
compatible with contact closure, open collector or voltage sink/source pulse transmitter input. The input pulse
must rise above V (high min.) for a period of time and
then fall below V (low) to be recognized as a pulse.
General
Electrical Outputs
Humidity:
5 to 95% with condensation.
AC Outputs:
Type: Optically-isolated, AC, solid-state relays.
User-programmable by the host as to function.
Remote Enclosure:
Explosion-proof (NEMA 7, Class I, Groups C and D) and
watertight (NEMA 4X), IP65
Approvals
Steady-State Load Current Range: 0.05A (rms) minimum to 0.5A (rms) maximum into an inductive load.
UL/CUL:
Class I, Division 1, Groups C and D; Class II, Groups E, F
and G, UNL-UL Enclosure 4X, CNL-CSA Enclosure 4.
Environment
Ambient Operating Temperature
-40oF to 140oF (-40oC to 60oC).
Modeling1
ALIII
XP
ALX1
A00000
Hardware Option
ALIII - S
ALIII - Q
Blank - None
A - AICB Board
AA - (2) AICB Boards*
M - ComFlash Mass Storage
Expansion Board3
AM - AICB Board and ComFlash
AAM - (2) AICB Boards and
ComFlash*
Housing
XP - UL/CUL, EEx d IIB, IP65
DEMKO A/S
Analog Modules2
DIGIT 1 - # of RTDs
DIGIT 2 - # of 4-20 mA inputs
DIGIT 3 - # of 4-20 mA outputs
DIGIT 4 - # of 1-5 Vdc inputs
DIGIT 5 - # of 1-5 Vdc outputs
Firmware
ALX1 - One-arm operation
ALX2 - Two-arm operation
ALX3 - Three-arm operation*
REM
XP
Model Designation
Hardware Option
Housing
A - AICB Board
XP - Explosion Proof
Programmable Inputs/Outputs4
AccuLoad III-S Hardware
Digital Inputs
Standard
Optional AICB
Digital Outputs
Standard
Optional
Analog Inputs/Outputs Up to 6
DC
6
16
DC
3
3
Total
11
21
Total
14
34
Digital Inputs
Standard
Optional (One AICB)
Optional (Two AICB's)
Digital Outputs
Standard
Optional (One AICB)
Optional (Two AICB's)
Analog Inputs/Outputs Up to 6
AC
9
9
9
AC
27
47
67
DC
143
24
34
DC
113
11
11
Total
11
33
43
Total
38
58
78
12.6"
(322)
21.6"
(547)
CL
13.8"
(351)
3.5"
(89)
7.8"
(198)
4.88"
(124)
3.5"
(89)
6.0"
(152)
8.5"
(216)
7.12"
(181)
3.75"
(85)
4.12"
(105)
17.0"
(432)
CL
10
7.30"
(185)
4.0"
(102)
8.0"
(203)
1 - 11.5" NPT
2 Places
8.0"
(203)
2.69"
(68)
7.5"
(190)
14.2"
(361)
8.5"
(216)
4.2"
(107)
3.00"
(76)
6.00"
(152)
11.8"
(300)
5.00"
(127)
2.5"
(64)
Back View
3.56"
(90)
2.87"
(73)
1.4"
(36)
4.2"
(107)
8.5"
(216)
11
2,50"
(64)
6,50"
(165)
13,4"
(340)
10,4"
(264)
2,00"
(51)
6,2"
(157)
1,50"
(38)
1,50"
(38)
9,75"
(248)
www.fmctechnologies.com/measurementsolutions
2014 FMC Technologies. All rights reserved.
FMC Technologies
Measurement Solutions, Inc.
500 North Sam Houston Parkway West,
Suite 100
Houston, Texas 77067 USA
P:+1 281.260.2190
USA Operation
1602 Wagner Avenue
Erie, Pennsylvania 16510 USA
P:+1 814.898.5000
Germany Operation
Smith Meter GmbH
Regentstrasse 1
25474 Ellerbek, Germany
P:+49 4101 304.0
12