0% found this document useful (0 votes)
106 views

Design of Power Pipe

The document summarizes the design of a steel pipe for a water conductor system for a 5 MW hydropower project. It lists the design discharge as 2.2 cubic meters per second plus 20% excess, totaling 2.64 cubic meters per second. Using references on hydraulic structures and open channel design, a trial and error method determined the optimal pipe diameter is 1350 mm to pass the design discharge at a slope of 1:300, with a flow velocity of 2.51 meters per second.

Uploaded by

balasharda
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
106 views

Design of Power Pipe

The document summarizes the design of a steel pipe for a water conductor system for a 5 MW hydropower project. It lists the design discharge as 2.2 cubic meters per second plus 20% excess, totaling 2.64 cubic meters per second. Using references on hydraulic structures and open channel design, a trial and error method determined the optimal pipe diameter is 1350 mm to pass the design discharge at a slope of 1:300, with a flow velocity of 2.51 meters per second.

Uploaded by

balasharda
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

RUKTI II SHEP (5.

00 MW)

DESIGN OF STEEL PIPE FOR WATER CONDUCTOR SYSTEM


Design criteria
It is proposed to provide steel conduit as the water conductor system

References
Irrigation and hydraulic structures by S.K.Garg
Theory and design of hydraulic structures(vol-ii) by R.S.Varshney,S.C.Gupta and
R.L.Gupta
Code of practice for open power channel IS-7916
Code of practice for design of c/s of lined channels IS-4745
Design parameters
Design discharge for power generation
Add 20 % for excess drawl
Design discharge for power conduit
Slope of pipe

=
2.20
=
0.44
=
2.64
= '1:300

cumecs
cumecs
cumecs

Let d be the diameter of pipe to pass the design discharge


through the power conduit
Taking diameter of pipe as
diameter
1.45 meters
Area
= 3.142*d^2/4
3.142 *d
Wetted perimeter
=
Hydraulic radius
=
d/4
Velocity of flow
=
V = 1/n*r^2/3* s ^1/2
Value of
n=
0.011 S
=
300

By trial and error method


Diameter of pipe

1.34 m

Velocity of water

2.51 m/sec

1350 mm

SECTION OF POWER CONDUIT ADOPTED