Oliz
I'vegotatasktorecheckanexistingtank'soverflowprotectionsincetheoldpumpsupplyingthetankhasbeenreplacedby
twonewones.
Thetankreceivesoilywaterandisusedasasettletankwherethewaterflowstothewatertreatmentfacilitiesandtheoilis
skimmedoff.Thetankisanatmospherictankwithfloatingroof.Theoverflowlinehasasyphonbreakatitstopandthesizeof
thelineis14"(I.D=0,3398m)bothupstreamanddownstreamofsyphonbreak.Themaximuminflowfromthepumpsis700
m3/h.
Icameacrossanoldpost(http://www.cheresour...overflowline/(http://www.cheresources.com/invision/topic/15663
sizingtankoverflowline/))whichhadalotofgoodinformationbutIamstillnottotallyclearifIhaveunderstoodthe
problemcorrectly.
Basedonequation3inP.DHillsarticleaboutgravityflow,hiscalculatedasfollows:
http://www.cheresources.com/invision/topic/22029sizingtankoverflowline/
1/4
17.10.2015
SizingTankOverflowLineIndustrialProfessionalsCheresources.comCommunity
h>0.811*(QL)2/(g*d4)=0,811*(700/3600)2 /(9,81*0,33984)=0,234m(2,29kPa)
Ialsocalculatedthepressuredropfromtheinletoftheoverflowpipetothetopbasedondarcyweisbachequation(justfor
comparison)andgotaresultof5.21kPawhichequals0,532m.
BasedonthecalculatedheightsIdrawthefollowingconclusions.
1.IfthemaximumlevelofthefloatingroofisabovetheheightoftheUbend+theheightcalculatedabovetherewillbeno
problem.
2.Ifthemaximumheightisnothighenough,thenthefloatingroofmustbeabletohandleatleast2,29kPag(or5.21kPag
basedondarcyweisbach)causedbyliquidpushingupwardsonthefloatingroof.Atthispressurethefullinflowcanbe
accomodatedintheoverflowline.
Nextthing,istocheckthefroudenumber.AsdefinedbyP.DHillsitiscalculatedlikethis:
JL<(2*h/d)0.5=(2*0,234/0,3398)0.5=1,175
FromthisIdrawtheconclusionthattheflowisnotselfventingandairwillbesuckedinthroughthesyphonbreakwhichinmy
applicationdoesnotmatter.
Anycomments?HaveIunderstoodtheproblemandthetheorycorrectly?
AttachedFiles
(http://www.cheresources.com/invision/index.php?
app=core&module=attach§ion=attach&attach_id=9298)overflowline.pdf
(http://www.cheresources.com/invision/index.php?app=core&module=attach§ion=attach&attach_id=9298)
37.03KB109downloads
Posted28November201406:40AM
katmar
Equation3fromtheHillsarticleisforthecasewhentheoverflowoutletisatthesurfaceleveloftheliquid,andtheliquid
overflowsdirectlyintotheoutlet.YouroutletistotallysubmergedsoEquation3doesnotapply.AsfarasIcansee,youhave
appliedtheDarcyWeisbachanalysiscorrectly.YourflowsarequitehighforthepipediametersyouhavesoIwould
recommendasubstantiallysizedsiphonbreak.
Posted28November201406:50AM
Oliz
katmar,on28Nov20142:50PM,said:
Equation3fromtheHillsarticleisforthecasewhentheoverflowoutletisatthesurfaceleveloftheliquid,andtheliquidoverflowsdirectly
intotheoutlet.YouroutletistotallysubmergedsoEquation3doesnotapply.AsfarasIcansee,youhaveappliedtheDarcyWeisbach
analysiscorrectly.YourflowsarequitehighforthepipediametersyouhavesoIwouldrecommendasubstantiallysizedsiphonbreak.
Thankyouforyourreply.So,iwillusetheheightandpressurevaluescalculatedfromthedarcyweisbachequationinsteadof
equation3.Thesiphonbreakinstalledis3".Isthereawaytocalculatethesizerequiredorismorebasedonrulesofthumbs?I
guesswhatlimitsyouisthatifthepressuredropinthesiphonbreakistoolargeduetolargeamountsofairbeeingsuckedin
basedonthehighfroudenumber,thesiphonbreakmightnotworkandthereisariskforthesiphoneffectatleastforashort
periodoftime.
Posted01December201410:32AM
katmar
Idonotknowofareliableandprovenwayofsizingsiphonbreakvents,andIsuspectthatyouarecorrectinthatmostare
sizedbyrulesofthumborbygutfeel.ThereisagroupattheKoreannuclearresearchfacilitythathasdonealotofworkover
theyearsbuttheirresultsdon'tseemtohavereachedthepointofhavingarobustdesignmethodyet.Asearchontheterm
"soonhokangsiphonbreak"willgiveyousomeusefulhits.
UsuallyItrytodesignthistypeofUsealwiththedownlegbeingselfventing.Inthiscasetheliquidlevelinthedownlegis
fairlyconstantandverylittleairflowsinoroutoftheventandarelativelysmallventisadequate.Butthisobviouslyresultsin
largepipingwhentheflowsarelargeandthisapproachisnotalwayspracticaloreconomic.
ForlargeflowsandnonselfventingdownlegsthewayIsizeventsisroughlyasfollowsYouwantthesiphontobreakwhen
http://www.cheresources.com/invision/topic/22029sizingtankoverflowline/
2/4
17.10.2015
SizingTankOverflowLineIndustrialProfessionalsCheresources.comCommunity
thesurfacelevelinthetankreachesthetopoftheUseal,i.e.whenyourdimension"h"becomeszero.Infacthwillbecome
slightlynegativebecauseforairtoflowintotheUsealthepressureinitmustbelessthanatmospheric.Thisnegativevalueof
hiscalledthe"undershoot".Ifyouselecttheundershootthatyouwantthenthisdefinesthepressureintheairspaceatthe
topoftheUseal.Ifthevolumetricflowofairthroughthesiphonbreakventmatchesthevolumetricflowofliquidinthe
downlegoftheUsealthennoliquidwouldflowfromthetankandthesiphonwouldbebroken.
Thepressuredropoverthesiphonbreakventisdefinedbythedifferencebetweenatmosphericpressureandtheundershoot
pressure.ThemaximumvolumetricflowofthewatercanbecalculatedknowingtheheightoftheUsealandthelengthof
piping(anditsfittings)andtheairflowwouldbethesameinvolumetricterms.Knowingthepressuredropandflowratefor
theventallowsyoutocalculatetherequireddiameterfortheventpipe.
ComparingmymethodwiththeresultspublishedbytheKoreangroupindicatesthatthisisafairlyconservative(i.e.safe)
approachbecauseinfactairisalreadystartedtobedrawninbeforetheundershootpressureisreachedandyoucangetaway
withasmallervent.Asyoumaketheventsmallerandsmallerthetimetakentobreakthesiphongetslongerandlongeruntila
sizeisreachedwherethesiphonwouldneverbebroken.Ihavenotfoundawaytopredictthedelayinbreakingthesiphonasa
functionoftheventsizeandsoIusemyconservativeapproach.
Ifyoucomeacrossanyotherdesignmethodpleaseshareithereasthisisacommonproblem,butonethathasnoclear
answer.
Posted08December201407:55AM
Oliz
katmar,on01Dec20146:42PM,said:
Idonotknowofareliableandprovenwayofsizingsiphonbreakvents,andIsuspectthatyouarecorrectinthatmostaresizedbyrulesof
thumborbygutfeel.ThereisagroupattheKoreannuclearresearchfacilitythathasdonealotofworkovertheyearsbuttheirresultsdon't
seemtohavereachedthepointofhavingarobustdesignmethodyet.Asearchontheterm"soonhokangsiphonbreak"willgiveyousome
usefulhits.
UsuallyItrytodesignthistypeofUsealwiththedownlegbeingselfventing.Inthiscasetheliquidlevelinthedownlegisfairlyconstantand
verylittleairflowsinoroutoftheventandarelativelysmallventisadequate.Butthisobviouslyresultsinlargepipingwhentheflowsare
largeandthisapproachisnotalwayspracticaloreconomic.
ForlargeflowsandnonselfventingdownlegsthewayIsizeventsisroughlyasfollowsYouwantthesiphontobreakwhenthesurfacelevel
inthetankreachesthetopoftheUseal,i.e.whenyourdimension"h"becomeszero.Infacthwillbecomeslightlynegativebecauseforairto
flowintotheUsealthepressureinitmustbelessthanatmospheric.Thisnegativevalueofhiscalledthe"undershoot".Ifyouselectthe
undershootthatyouwantthenthisdefinesthepressureintheairspaceatthetopoftheUseal.Ifthevolumetricflowofairthroughthe
siphonbreakventmatchesthevolumetricflowofliquidinthedownlegoftheUsealthennoliquidwouldflowfromthetankandthesiphon
wouldbebroken.
Thepressuredropoverthesiphonbreakventisdefinedbythedifferencebetweenatmosphericpressureandtheundershootpressure.The
maximumvolumetricflowofthewatercanbecalculatedknowingtheheightoftheUsealandthelengthofpiping(anditsfittings)andthe
airflowwouldbethesameinvolumetricterms.Knowingthepressuredropandflowratefortheventallowsyoutocalculatetherequired
diameterfortheventpipe.
ComparingmymethodwiththeresultspublishedbytheKoreangroupindicatesthatthisisafairlyconservative(i.e.safe)approachbecause
infactairisalreadystartedtobedrawninbeforetheundershootpressureisreachedandyoucangetawaywithasmallervent.Asyoumake
theventsmallerandsmallerthetimetakentobreakthesiphongetslongerandlongeruntilasizeisreachedwherethesiphonwouldneverbe
broken.IhavenotfoundawaytopredictthedelayinbreakingthesiphonasafunctionoftheventsizeandsoIusemyconservative
approach.
Ifyoucomeacrossanyotherdesignmethodpleaseshareithereasthisisacommonproblem,butonethathasnoclearanswer.
Thankyouagainforverygoodinformation.IreadthatarticlefromtheKoreanresearchgroupwhichexplainedthe
phenomenaverywell(http://www.google.co....80642063,d.bGQ(http://www.google.com/url?
sa=t&rct=j&q=&esrc=s&frm=1&source=web&cd=3&ved=0CCcQFjAC&url=https%3A%2F%2Fptop.only.wip.la%3A443%2Fhttp%2Fwww.researchgate.net%2Fprofile%2FHo_Seon_Ah
scaled_research_reactor_pool%2Flinks%2F02e7e534bb4d73eee1000000&ei=Q6KFVMq8KsTnywOpwIH4Dg&usg=AFQjCNGf5sseHNO3HfWP
)
Iwilltrytoexplainmythoughtprocess.
AtthemomentwhenthepressuredropintheUtubeisovercome,i.e.whenthelevelinthetankishmetersabovetheUtube
centerline,waterwillstartsiphoningoutofthetank.Duetothepressuredrop,therewillbeanegativepressureatthetopof
theUtube.Theflowratewillbeatitshighestshortlyafterthestartofoutflow.Thepressuredropduetoflowofwaterwill
resultinanegativeabsolutepressureatthetopoftheUtube,decreasinginthebeginningasthelevelinthetankdecreases.In
thearticletheprocessisdividedin4stages.AttheendofstageA,justwhentheinflowofairwillstarttohaveaneffectonthe
pressuredropinthedownwardpipe,theabsolutepressurewillbeatitslowestatthetopoftheUtube.Thispressurewill
actuallybeslightlylowerthanthe5.21kPagcalculatedaboveduetotheeffectoflowerliquidlevelinthetank.
Duetothenegativepressure,airwillbesuckedinandbecomeentrainedintheliquiddownwardpipeandwillresultinlarger
andlargerpressuredropinthedownwardpipehinderingtheflowofwater.Atonepoint,theamountofairsuckedin
http://www.cheresources.com/invision/topic/22029sizingtankoverflowline/
3/4
17.10.2015
SizingTankOverflowLineIndustrialProfessionalsCheresources.comCommunity
comparedtotheliquidflowislargeenoughtobreakthesiphon.
Asaresultoftheresearchteamnothavingaflowmeteronthesiphonbreakertomeasuretheair/waterratiowhenthesiphon
brokeinthedifferentexamplesI'lluseyourruleofthumb.
Aslongasthepressuredropfortherequiredairflow(inthiscasein700m3/hwhichisequaltothemaximumliquidinflow)
throughthesiphonbreakerislowerthan5.21kPag,enoughairwillbeabletobesuckedintobreakthesiphonwithminimal
undershootonlydependantonthetransientnatureofthebackpressureinthedownwardpipe.Inmycase,thesiphonbreaker
isa550mmpipe(ID=107.1mm)withtwo90degreeLRelbowsforminga180degreebend.Icalculatedtheairflow@a
pressuredropof5.21kPagto3,900Nm3/hwhichismuchlargerthantherequiredflowsobasedonthisIthinkthatthe
siphonislargeenoughforthiscase.
Iftheinstalledsiphonbreakeristoosmall,theundershootwillnotonlybedependantonthetransientnatureofthe
backpressureinthedownwardpipecausedbyairinflowbutalsoonthelevelinthetankthatwillneedtodecreasetoacertain
levelbeforeyouwillreachyourdesiredinflowofair.
EditedbyOliz,08December201407:56AM.
BacktoIndustrialProfessionals
PotableWaterTransferPumpSelectionAndSizing
StartedbyGuest_Chemical.Engineer_*,07Oct2015
PressureSafetyValveInletAndOutletLineSizing
StartedbyGuest_Light_*,14Oct2015
StoringEnzymeInRefrigeratedStorageTank
StartedbyGuest_MCCreen_*,14Oct2015
SizingOfTankHeatingCoil
StartedbyGuest_franchescamarie_*,09Oct2015
TankManagementSystem
StartedbyGuest_ShahKhan_*,11Oct2015
HOT
12replies
277views
Yesterday,10:11PM
3replies
108views
15Oct2015
0replies
36views
14Oct2015
3replies
220views
12Oct2015
1reply
137views
11Oct2015
http://www.cheresources.com/invision/topic/22029sizingtankoverflowline/
4/4