0% found this document useful (0 votes)
379 views

Control Valve Calculation Spreadsheet

This document is a calculation sheet for a fluid properties and piping sizing calculation for a process involving liquid flow. It lists the fluid properties, process data like pressures and flow rates, valve and piping data like line number, sizes and coefficients. It then shows the calculations for pressure differentials at choked and non-choked conditions, resistance coefficients and combined factors to determine the required valve CV of 216.1.

Uploaded by

petrolhead1
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
379 views

Control Valve Calculation Spreadsheet

This document is a calculation sheet for a fluid properties and piping sizing calculation for a process involving liquid flow. It lists the fluid properties, process data like pressures and flow rates, valve and piping data like line number, sizes and coefficients. It then shows the calculations for pressure differentials at choked and non-choked conditions, resistance coefficients and combined factors to determine the required valve CV of 216.1.

Uploaded by

petrolhead1
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

Calculation Sheet

XX-XXXXXX

CAL-PR-0100

CUSTOMER
NAME:

Petrofac Process Department

CONTRACT
NAME:

Calculation Verification
CALCULATION

Ref.

Fluid Properties

Fluid =
=
=
=
Liquid density, r
=
Liquid viscosity, m

Liquid
221
0.71
965.4
3.147

bara
bara
kg/m
cP

=
=
=

6.8
2.2
360

bara
bara
m/h

=
=

210
3

inch

inch

Nominal outlet valve size, d =


Internal diameter downstream expander, D 2 =
Pressure recovery factor for valve, FL =

inch

inch

Critical pressure, Pc
Vapour pressure, Pv

Rev.

Process Data
Upstream pressure, P1
Downstream pressure, P2
Volumetric flowrate,
Q
Valve and Piping Data
Line number
Initial valve Cv
Nominal inlet valve size, d
Internal diameter upstream reducer, D 1

Pressure recovery factor for valve, FL =


FL value to be used =
Pressure differential at non-choked conditions
Pressure differential at choked conditions

=
=
=
Flow through valve is
Pressure differential used for sizing =
Sum of resistance coefficient, =
Upstream resistance coefficient, 1 =
Piping geometry, Fp =
Combined factors, FLP

0.9

Default value

User value

0.9
4.60
4.21
Choked
4.21
0.287

bar
bar
bar

0.779
0.922
0.764

Liquid critical pressure ratio factor, FF =


Specific Gravity
=

0.944
0.965

Calculated CV =

216.1

187