0% found this document useful (0 votes)
29 views

1laboratory Work N5

The document describes an experiment to determine the noise level at which different satellites would stop operating. A table shows the signal strength in dB for several satellites at increasing noise levels from 0 to 50 dB. The summary shows that satellite 10 and 32 stopped operating at 30 dB noise, satellite 3 stopped at 35 dB, and satellite 23 was the last to stop at 40 dB noise. Dilution of precision values also increased with higher noise levels.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
29 views

1laboratory Work N5

The document describes an experiment to determine the noise level at which different satellites would stop operating. A table shows the signal strength in dB for several satellites at increasing noise levels from 0 to 50 dB. The summary shows that satellite 10 and 32 stopped operating at 30 dB noise, satellite 3 stopped at 35 dB, and satellite 23 was the last to stop at 40 dB noise. Dilution of precision values also increased with higher noise levels.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
You are on page 1/ 1

Laboratory work 5

Weve chosen the satellites in zenith. And we want to see which of them at which noise level will die.
The corresponding table is build:
Noise/S
V
0
5
10
15
20
25
30
35
40
45
50

SV23
L1
50.40
50.29
49.96
48.88
45.88
41.17
37.00
31.77
28.03
0.05

L2
47.76
47.63
47.23
46.54
44.61
40.26
35.31
35.09
0.05
0.05

SV3
L1
49.63
48.83
47.96
46.58
44.06
39.37
34.74
29.36

SV32
L2
48.64
48.05
47.78
47.06
45.04
41.34
35.03
22.77

L1
39.63
38.34
37.98
36.78
34.24
29.14
20.02

L2
40.27
38.34
37.05
34.79
25.24
35.909
0.05

SV10
L1
40.20
39.53
39.30
37.62
33.27
29.31
24.25

L2
38.08
36.51
38.91
37.02
37.11
41.27
0.05

We see that at 30 dB noise 10th and 32th SVs stopped operating, then 3rd one at 35 dB, and the last 23th at 40
dB.

As for DOPs, they increase with the increase of noise level.