Position Transmitters Working

Brief description on how position transmitters work

Uploaded by

sdfsfg
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF or read online on Scribd
You are on page 1/ 4
n Transmitters & Positioners besten of tho valve can be dotorminod acourately and precicoly using oithor contact typo or non-contact typo n_ transmitters. Contact type position transmitters includes Polentiometer and Electronic Position Transmitters (RWG 1001 7 RWG 2002 / RWG 2002 DG) whereas non-contact fype poston tranemiters include Inductive Position Transmitters (IWG 1002/IWG 1003). Potentiometer Apotentiometer is used as sensor for actuator. Single tum wire wound potentiometer with 4.7 kOhm with Technical Data - RWG 1001 linearity £0.5% is available for this purpose. Itis - available in single or tandem version. ‘Configuration 3 Wire Technical Data - Potentiometer ‘Supply Voltage i Resistance 4.7 kOhm 20.5% ‘Output Current 0/4-20mA Power Rating 3 Watt at 40°C Input Resistance 150 kOhms: Angle of Rotation 275" 25° Displacement of zero | psa, —— position, Max. Linearity 20.5% Displacement of ond peice from 50 to 100% Electronic Position Transmitter RWG1001 bended cd Max. 0.2% This device is a signal converter for the transformation | YN@9® of resistance value into proportionate current signal. it | Temp. Drift 0.2% 10°C. can also be placed in the actuator where the position determined by the potentiometer is converted into4-20 | Linearity not considering mAcurrentsignal. potentiometer 0.05% As position transmitter, preferably a potentiometer of 4.7 kOhm should be used so that the reference voltage source is not This device requires 24 V DC power supply regulated within +15%. Auma power supply unit PS 01 is recommended for this purpose. RWG 1001 isa 3 wire system and shaving ineariy of 0.05%. Electronic Position Transmitter RWG 2002 This is basically same as RWG 1001, however with 2 wire system. The linearity is less than 1%. 7a ‘iia RWG 2002 Position Transmitters & Positioners ‘Technical Data - RWG 2002 Configuration 2Wire Supply Voltage 24V DG Mn. 18, Ouput Current 4-20 mA Input Resistance 150 kOhms Displacement of Zero Position, pees 425% Displacement of End Position, hae From 60 to 100% Influence of supply voltage ee Max. 0.15% Linearity not considering <1% potentiometer Dual Output Position Transmitter RWG 2002 DG Itis a signal converter device for the transformation of rasistance value into proportionate galvanically isolated two current outputs. This device requires 24 V DC power supply regulated within 410%. Auma power ‘supply unit PS 01 is recommended for this purpose. Inductive Position Transmitter |WG 1002 When using Auma actuators for regulating duty with demand of high accuracy, an inductive position transmitter can be fitted to give precise read out of position, ‘The output signal is used as feedback to electronic positioner or for position indicator. The system consists of two parts, a linear variable differential transformer (LVDT) and an electronic unit. The smallest change of ‘magnetic core in the measuring coil is transformad into proportional signal. The transmitter has no moving contacts. This device requires 24 V DC power supply regulated within 15%. Auma power supply unit PS 01 is recommended for this purpose. The linearity of the unitis tess than 0.3%. IWG 1002 Technical Data - WG 1002 poets aL wa! wi Configuration 2Wire ae ren ANG | 02 0G / 24VDC aan Gls Tiss Supply Voltage +£15% regulated vist Ig ne = ‘Output Current 4-20 mA Technical Data - RWG 2002 DG RoE, 600 Ohms 24VDC ie Supply Voltage 110% regulated | | Diewaoorentofzere | 425% Output 1 (Isolated) (0/420 mA Output 2 (Isolated) 0/4-20mA eee 60 to 100% Sere Drea 100 mA Temp. dit 0.4% / 10°C Adjustability of Span 450% Linearty (not considering | < 9 44 Adjustability of Zero 225% LVDT) . Change in Output due to Input Supply Variation poet Linearity Errorfor both Outputs =| <1% Position Transmitters & Positioners Inductive Position Transmitter IWG 1003 IWG 1003 is similar to IWG 1002 however with 3 wire system, ‘Technical Data - IWG 1003 Eloctronic Positionor CU 04 The electronic positioner CU 01 is designed as a three level positioner for regulating of actuator. By comparing ‘two input signals (reference signal W & regulating signal . the positioner determines the difference. ‘9 this is a certain value, the actuator is switched. on by relays. The direction of rotation {opening or closing) depends upon the plus or minus sign of the deviation. Thus, the regulating signal generated by potentiometer or LVDT changes & when the regulating signal & reference signal become equal, the actuator stops as long as no new correction is required. cuo1 Technical Data - CU 01 Configuration 3Wire Supply Voltage Stee tagubio Output Curent 0/4-20mA Resistance Max. 600 Ohms Displacement of zero position, Max. 225% lacement of end Depeeeetotor? cow 10 Temp. drift 0.4% / 10°C Linearity {not considering heat <03% Input Wet 0-20 mA(4-20 mA) Xer 0-20 mA (4-20 ma) or 0 - Uref Time delay 1-20 sec. Adjustment of zero point | 0 - 20% Adjustment of end Rear 60 to 100% Sensitivity (dead band) | 1% - 10% Relay output (max. resistive load) 230, 104 * Positioner with Pulse Width Modulation are available for critical applications. Position Transmitters & Positioners Signal Isolator ‘Auma signal solator are available in various versions: Powersupply conditions: 230 VAG, 110 VAG or 24 VDC Various input signals: 4-20MA oF1-5V =D Signal Isolator Various output signals: 4-20 mAsingle or dual or 4 - 20 mA&1-5V. Isolation is provided between input and output and also between two outputs. Technical Data - Signal isolator Uo, thus Uc can serve as common reference potential for whole regulating system. ‘Supply voltage to PS 01 is 220 Vor 110 V+15%, 50 Hz ‘The maximum output voltage is Uo=24V+1VDC Uc=5.5V20.5VDC Version | Version Il: For remote position indication with potentiometer 220 Chms as position transmitter. In this, two additional potentiometers P1 and P2 are provided for positions zero and maximum. A voltmeter of 1 V, calibrated in % is used for visual indication of valve travel. This voltmeter is Raney qanvaciiee connected to the PS 01 (Version II) as shown 24aVDCz1V below: Input Signal 7 7 eo mi 4-20 mAsingle sar ‘Output Signal 4-20 mAdual = 4-20mA&1-5V Accuracy 40.1% of output sapn nena (Y , 42% min. at zero Version I Zero & spen adjustment | 40%, min. al span Technical Data - PS 01 Power Supply Unit PS 01 ‘Supply voltage and | 220 V or 118 V (215%) frequency 50 Hz 0r60 Hz This unit gives 24 V DC power supply for electronic positioner CU 01 and electronic position transmitter, in | Power drawn SVA case 24 V DCisnotavailable atsite. Version|: For regulating application with CU01: The output voltage Uo & Uc require no trimming | Amounting ee potentiometer. The voltage Ucis diverted from voltage

You might also like