This document provides design details for bored piles including: - Concrete grade of 40 MPa and steel grade of 460 MPa with a factor of safety of 1.2 and minimum reinforcement of 0.5%. - Pile diameters range from 900mm to 1600mm with associated reinforcement details. - Structural load capacity is provided for different pile diameters, concrete grades, and limit states. - Design of rock sockets summarizes allowable rock bearing and skin resistance values based on the unconfined compressive strength of three rock types.

Uploaded by

Ong George Sammy
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
178 views

Bore Pile Design

This document provides design details for bored piles including: - Concrete grade of 40 MPa and steel grade of 460 MPa with a factor of safety of 1.2 and minimum reinforcement of 0.5%. - Pile diameters range from 900mm to 1600mm with associated reinforcement details. - Structural load capacity is provided for different pile diameters, concrete grades, and limit states. - Design of rock sockets summarizes allowable rock bearing and skin resistance values based on the unconfined compressive strength of three rock types.

Uploaded by

Ong George Sammy
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
You are on page 1/ 2

BORED PILE SUMMARY FOR :

Grade of concrete =
40
Steel grade =
460
FoS = 1.2
Minimum % reinforcement =

AROMA
45

0.5

SUMMARY OF STRUCTURAL CAPACITY OF PILES AND REINF DETAIL


A) Compression Pile

Pile
Diam
900
1200
1400
1600

Area
m2
0.636
1.131
1.539
2.011

MAIN REINFORCEMENT
min.reinf
(use T bars)
% area
cm2
nos
diam
3181
25
0.93
12
5655
25
0.87
20
7697
25
0.83
26
10053
25
0.88
36

size
12
12
12
12

LINK
(use R bars)
spacing
@
300
@
300
@
300
@
300

A) Compression Pile

Pile
Diam
900
1200
1400
1600

Area
m
0.636
1.131
1.539
2.011
2

MAIN REINFORCEMENT
min.reinf
(use T bars)
% area
cm2
nos
diam
3181
25
1.54
20
5655
25
1.48
34
7697
32
1.57
30
10053
32
1.52
38

0.25FcuAc
Grade 40

size
12
12
12
12

0.35FcuAc
Grade 40

Grade 45

Structural
Load (kN)

Structural
Load (kN)

Structural
Load (kN)

Structural
Load (kN)

6362
11310
15394
20106

7157
12723
17318
22620

8906
15834
21551
28149

10020
17813
24245
31667

0.25FcuAc
Grade 40
LINK
(use R bars)
spacing
@
300
@
300
@
300
@
300

Grade 45

Grade 45

0.35FcuAc
Grade 40

Grade 45

Structural
Load (kN)

Structural
Load (kN)

Structural
Load (kN)

Structural
Load (kN)

6362
11310
15394
20106

7157
12723
17318
22620

8906
15834
21551
28149

10020
17813
24245
31667

0.35FcuAc+0.67FyAsc
Grade 40
Grade 45
Structural Load Structural Load
(kN)
(kN)
9088
18859
25485
33595

10201
20839
28179
37114

Highest Load
Service Load

Factor 1.5

Factor 2.0

3527

5291
15630
17696
21153

7054
20840
23594
28204

10420
11797
14102

0.35FcuAc+0.67FyAsc
Grade 40
Grade 45
Structural Load Structural Load
(kN)
(kN)
9209
20977
28987
37568

10322
22957
31681
41086

Highest Load
Service Load

Factor 1.5

Factor 2.0

3527

5291
15630
17696
21153

7054
20840
23594
28204

10420
11797
14102

DESIGN OF ROCK SOCKET


SUMMARY OF N VALUES AND fs AND fb
Rock
When rock is encountered, following values are adopted:Allowable rock bearing is conservatively taken as 0.3 x quc, rock unconfine compressive strength
(Poulos and Davis 1980), value of 0.2 quc is adopted for our design
Ultimate skin resistance is taken as 0.1 quc, using safety factor of 2, allowable skin resistance is taken as 0.05quc
however, value not exceeding 0.02 quc is adopted in our design
Following values has been adopted depending on unconfine compressive strength of rock

Rock

type 1

type 2

type 3

fsa, allowable rock friction


resistance ( KN/m2) =0.02quc

fba, Allowable base


resistance ( KN/m2) = 0.2 quc

Highly fractured and weak


granite

600
adopt

500

6000
adopt

5000

Fractured and
moderately strong granite

1200
adopt

1000

12000
adopt

10000

Fresh slightly fractured and


strong granite

2000
adopt

1600

20000
adopt

16000

minimum unconfine
rock compressive
strength(KN/m2), quc
30000

60000

100000