Pulse Transformer Design
Pulse Transformer Design
hundred kilo hertz. The main significance of these transformers is in Switched Mode Power
Supplies. The main conceptual idea of Switched Mode Power Supply is that it is using energy
efficient devices to transfer/convert the Power (A.C./D.C) from the source to the sink/load. One
such energy efficient device is High Frequency Pulse Transformer. The switching frequency of
these SMPSs (Switched Mode Power Supply) system will be very high as a concern it reduces
the size of magnetics (like transformer and inductor) and and it reduces the ripple and so on. In
later sessions we will be discussing about complete design of High frequency transformer from
fundamentals for a DC-DC converter as an application.
Popularly EE Cores is used to form the Shell type High frequency transformer. Its geometric
Faradays
B)
respectively.
As discussed earlier Window area of a transformer provides accommodation for primary and
secondary winding. But entire window area is not used for the winding a portion of it is used for
insulation therefore a factor Kw is introduced which is called window space factor or window
utilization factor.
From
J= 3 A/mm2, Kw= 0.35. Step 1: Selection of Core. From the equation (3) that we
have derived, there substituting all the values and finding the value of window and
core area.
After we derive this
value, from the data sheets of the Core we need to select the appropriate core. A
typical data for ETD Cores is given below,
ETD Core Series Data
Type Number
Ac (mm2)
Aw (mm2)
AcAw (mm4)
ETD 29/16/10
76
128
9728
ETD 34/17/11
97
171
16587
ETD 39/20/13
125
234
29250
ETD 44/22/15
173
279
48267
ETD 49/25/16
211
343
72373
ETD 54/28/19
280
412
115360
ETD 59/31/22
368
473
174064
From the above table we can conclude that ETD 49/25/16 is the required core for
our application. Step 2: Deriving No. of Primary Turns and No. of Secondary (N 1 and
N2)
Step 3: Deriving
primary and secondary conductor size/gauge(a 1 and a2) Generally for copper
conductor the current density J is taken as 3A / mm 2.
inductance.
Note: The value of le
& Ac is taken from the core magnetic characteristics as shown in the below for
ETD49/25/16 Core. The value of r/ e is taken from core material characteristics.
For instance let the core material is ungapped N27 material. The data for ETD
49/25/16 Core is shown below.