0% found this document useful (0 votes)
49 views

Midas CTD 606 Setup

This document provides instructions for setting up a CTD device using DataLog Express software to record oceanographic data. The steps include opening the software, selecting the correct COM port to communicate with the device, configuring the setup profile to record pressure, temperature, and salinity at 1 second intervals starting from 0.1, entering site information, setting the pressure tare, running a self-recording test deployment, and then uploading the recorded CTD data file after recovery for analysis in the software.

Uploaded by

faisal
Copyright
© © All Rights Reserved
Available Formats
Download as DOC, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
49 views

Midas CTD 606 Setup

This document provides instructions for setting up a CTD device using DataLog Express software to record oceanographic data. The steps include opening the software, selecting the correct COM port to communicate with the device, configuring the setup profile to record pressure, temperature, and salinity at 1 second intervals starting from 0.1, entering site information, setting the pressure tare, running a self-recording test deployment, and then uploading the recorded CTD data file after recovery for analysis in the software.

Uploaded by

faisal
Copyright
© © All Rights Reserved
Available Formats
Download as DOC, PDF, TXT or read online on Scribd
You are on page 1/ 10

CTD SETUP

Open DataLog Express

Click communicate

Select COM1 ---->RS232---->Baud Rate 9600----->Click Next


(if couldnt connect then try and error)
[Type: Depends on which cable/method u connect]

Click Next

Click Change Setup

Select Profile------>Next

Tick Synchronise instrument to PC when setting instrument ----->Next

Select Metric---->Tick Apply to pressure---->Next

Set Profile Start Point (0.1) & Profile Interval (1.0) --> Next

Enter site information, Local latitude (biar) ---->Next


Tick Set Pressure Tare ---->Finish Setup

Click Run
Select Self recording ----> Next

Select OK. Equipment ready to deploy.


Cucuk 9pin plug , observe the blinking. Blinking stop Deploy.

After Recover, CTD Data Upload

Click Communicate

Click Next

Click Next

Click Upload Screen

Select the data acquired (Usually the latest and biggest file size) -----> Click
Upload Files

Click OK. Open data in c:\Valeport Software\DataLog Express\(serial no folder).


Check acquire data: date, pressure (Depth), salinity etc.