0% found this document useful (0 votes)
631 views3 pages

BCF Small Animal Exposure Charts Digital Radiography DR 80cm Distance 0412

The document provides a chart with suggested exposure settings for direct digital radiography of various small animal body parts and structures without a grid. It lists thicknesses for different areas and species and the corresponding recommended kilovoltage and milliampere-seconds for proper exposure. Adjusted settings are also provided.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
631 views3 pages

BCF Small Animal Exposure Charts Digital Radiography DR 80cm Distance 0412

The document provides a chart with suggested exposure settings for direct digital radiography of various small animal body parts and structures without a grid. It lists thicknesses for different areas and species and the corresponding recommended kilovoltage and milliampere-seconds for proper exposure. Adjusted settings are also provided.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

BCF Technology small animal exposure chart

Direct Digital Radiography systems (DR)


Suggested exposures are for a Focal Spot/Film Distance (FFD) of 80cm
without a grid

Thorax VD/DV view

Thorax lateral view


Thickness
(cm)

Suggested
kV

Suggested
mAs

Adjusted
kV

Adjusted
mAs

Thickness
(cm)

Suggested
kV

Suggested
mAs

60

60

60

60

12

70

1.5

12

65

1.5

15

70

1.5

15

70

1.5

Adjusted
kV

Adjusted
mAs

Medium Dog

Medium Dog
18

70

18

75

2.5

21

75

21

75

2.5

23

75

23

80

80

Large Dog

Large Dog
25

80

25

Abdomen lateral view


Suggested
kV

Suggested
mAs

Cat/Small Dog

Abdomen VD/DV view


Adjusted
kV

Adjusted
mAs

Thickness
(cm)

Suggested
kV

Suggested
mAs

Cat/Small Dog

50

50

50

50

10

50

10

55

12

55

12

55

4.5

14

60

14

60

16

65

16

65

Medium Dog

Medium Dog

18

70

18

70

20

70

20

75

22

80

22

80

80

8-10

Large Dog
24

Adjusted
mAs

Cat/Small Dog

Cat/Small Dog

Thickness
(cm)

Adjusted
kV

Large Dog
80

8-12

24

Your ultrasound and X-ray people


+44 (0)1506 460 023 | [email protected] | facebook.com/bcftechnology | www.bcftechnology.com

BCF Technology small animal exposure chart


Direct Digital Radiography systems (DR)
Suggested exposures are for a Focal Spot/Film Distance (FFD) of 80cm
without a grid

Pelvis/Hips VD view

Pelvis/Hips lateral view


Thickness
(cm)

Suggested
kV

Suggested
mAs

Adjusted
kV

Adjusted
mAs

Thickness
(cm)

Suggested
kV

Suggested
mAs

Adjusted
mAs

Cat/Small Dog

Cat/Small Dog
8

50

50

10

50

2.5

10

50

12

50

12

55

14

55

14

55

16

55

16

60

Medium Dog

Medium Dog
18

60

18

60

20

65

20

65

70

Large Dog

Large Dog
22

70

22

Extremities lateral and CC/DP views


Thickness
(cm)

Adjusted
kV

Suggested
kV

Suggested
mAs

Cat/Small Dog

Adjusted
kV

Adjusted
mAs

Skull lateral and DV/VD views


Thickness
(cm)

Suggested
kV

Suggested
mAs

Adjusted
kV

Adjusted
mAs

Cat/Small Dog

50

50

1.5

50

10

60

2.5

50

12

65

50

55

14

70

16

70

70

Medium Dog

Medium Dog

55

Large Dog

60

3.5

18

10

60

3.5

12

60

14

60

Large Dog

Your ultrasound and X-ray people


+44 (0)1506 460 023 | [email protected] | facebook.com/bcftechnology | www.bcftechnology.com

BCF Technology small animal exposure chart


Direct Digital Radiography systems (DR)
Suggested exposures are for a Focal Spot/Film Distance (FFD) of 80cm
without a grid

Thoracic Spine VD view

Thoracic Spine lateral view


Thickness
(cm)

Suggested
kV

Suggested
mAs

Adjusted
kV

Adjusted
mAs

Thickness
(cm)

Suggested
kV

Suggested
mAs

55

2.5

55

2.5

60

60

12

60

12

65

3.5

15

65

15

75

Medium Dog

Medium Dog
18

70

18

75

21

75

7.5

21

75

23

75

8.5

23

80

80

8-10

Large Dog

Large Dog
25

80

25

8-12

Cervical Spine lateral and VD views


Suggested
kV

Suggested
mAs

Cat/Small Dog

Adjusted
kV

Adjusted
mAs

Lumbar Spine lateral and VD views


Thickness
(cm)

Suggested
kV

Suggested
mAs

50

2.5

50

2.5

50

3.5

50

12

55

10

55

15

60

12

60

14

65

5.5

16

65

18

70

20

75

7.5

22

80

8.5

80

10-15

Medium Dog
18

65

21

60

23

75

Large Dog
80

Adjusted
kV

Adjusted
mAs

Cat/Small Dog

25

Adjusted
mAs

Cat/Small Dog

Cat/Small Dog

Thickness
(cm)

Adjusted
kV

8-12

Medium Dog

Large Dog
24

Your ultrasound and X-ray people


+44 (0)1506 460 023 | [email protected] | facebook.com/bcftechnology | www.bcftechnology.com