0% found this document useful (0 votes)
1K views

Ultrasonic Testing

DanSteel A/S supplies heavy steel plates that undergo ultrasonic testing to detect inclusions and laminations. Ultrasonic testing is performed according to various international standards on plates between 8-100mm thick. The surface of the plate is cleaned and coated with a coupling fluid before being tested by a semi-automatic device to measure any defects and ensure they are within standard limits, with results reported on certificates.

Uploaded by

Taesik Kim
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
1K views

Ultrasonic Testing

DanSteel A/S supplies heavy steel plates that undergo ultrasonic testing to detect inclusions and laminations. Ultrasonic testing is performed according to various international standards on plates between 8-100mm thick. The surface of the plate is cleaned and coated with a coupling fluid before being tested by a semi-automatic device to measure any defects and ensure they are within standard limits, with results reported on certificates.

Uploaded by

Taesik Kim
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

DanSteel A/S

Products

Ultrasonic testing
Application Ultrasonically tested heavy steel plates are used in the design and construction of
heavily stressed steel structures. The purpose of ultrasonic testing is to register
the position and size of any inclusions and laminations.
DanSteel A/S supplies ultrasonically tested heavy steel plates in thickness from
8 to 100 mm and length max. 16000 mm. For the strictest standards, delivery
thickness is normally restricted to max. 70 mm (i.e. EN 10160 S2, SEL 072-77
Class 2, BS 5996 Level E3, SIS Level 3).
Ultrasonic testing cannot be carried out for thickness below 8 mm.
_________________________________________________________________________________________________________

Standards Ultrasonic testing is carried out in accordance with the following standards:
EN 10160 Class 0, 1, 2.
SEL (Stahl-Eisen-Lieferbedingungen) 072-77 Class 2, 3, 4, 5.
ASTM A435 and A578 – A, B or (C).
BS 5996 Level B1, B2, B3, (B4), E1, E2, E3.
SIS 219115 Level 0, 1, 2, (3).
Testing in accordance with other standards/special test methods can be carried
out, subject to agreement.
________________________________________________________________________________________________________

Methods of testing The surface of the plate is cleaned thoroughly and then sprayed with a coupling
fluid (water).
The plate is subsequently tested by a semi-automatic device in accordance with
the rules given in the standard.
Any defects are measured and assessed in relation to the standard.
The testing of edges is carried out along all 4 edges.
______________________________________________________________________________

Example: Permissible defect size and number of defects.


EN 10160
S1 E1 Area Edges

Defect Max. number of defects Defect Max. Number of


mm² within 1 m² mm² length defects per m
of
defect Length
mm 25-50 mm
100-1000 15

100-1000 50 4

The result of the ultrasonic test is applied to the certificate.

Updated 22 September 2005

_________________________________________________________________________________________________________
DanSteel A/S, Havnevej 33 Phone: + (45) 47 77 03 33 CVR-nr.: 10 09 29 22
DK-3300 Frederiksværk Fax: + (45) 47 77 03 22 www.dansteel.dk