Load Test On Single Phase Induction Motor
Load Test On Single Phase Induction Motor
Aim
To conduct a load test on capacitor start single phase induction motor
Instruments used
1 ammeter(0-10A, MI) 1
2 Voltmeter(0-250V,MI) 1
3 Wattmeter(250V,10A,UPF) 1
4 Tachometer
Theory
Single phase induction motor is self starting. To make it self start a rotating magnetic field has to be
produced in the stator. This is achieved by converting a single phase supply by us of a auxiliary windingin
series with the capacitor.
Procedure
Connection are made as in the figure. Keeping the load minimum supply is given and start the motor.
Load is gradually increased till the rated current and reading are noted.
Sample calculation
Input - w
Torque - (s1-s2)Rxg where R= radius of breadrum And g=9.8m/s2
Output - 2 nt/60
Efficiency - output/input
%slip - (ns-n)x100/ns
Power factor - w/vi
Result
Load test was conducted and the performance characterstics have been plotted.
Aim
To determine the efficiency and regulation of single phase phase transformer(3 KVA,400,220V) by
conducting load test.
Instruments used
When the transformer is loaded with a constant primary voltage the secondary terminal voltage
decreases because of its internal resistance and leakage reactance. Change in secondary voltage from no
load to full load divided by no load voltage in regulation down and divided by full load voltage is
regulation up.
%regulation+ (no load voltage – full load voltage)x 100/no load voltage.
Procedure
Connections are made as in figure. With primary supply on ,secondary is loaded till rated current and
reading are noted
Sample calculation
Primary current I1 =
Primary voltage V1 =
Secondary current I2 =
Secondary voltage =
Output = V2I2
Input = W
Efficiency = outputx100/input
Result
Load test was conducted and the performance characteristics have been plotted
Aim
Instruments used
Theory
From open circuited and short circuited test we can determine value of core losses
Wo=voiocos$