3rt1025-1ap60,: Contactor, Ac-3 7,5 KW/400 V
3rt1025-1ap60,: Contactor, Ac-3 7,5 KW/400 V
General details:
Product brand name SIRIUS
Product designation power contactor
Size of the contactor S0
Protection class IP / on the front IP20
Degree of pollution 3
Installation altitude / at a height over sea level / maximum m 2000
Ambient temperature / during the operating phase °C -25…60
Active power loss / per conductor / typical W 0.9
Item designation
o according to DIN EN 61346-2 Q
o according to DIN 40719 extendable after IEC 204-2 / K
according to IEC 750
Main circuit:
Number of poles / for main current circuit 3
Number of NC contacts / for main contacts 0
Number of NO contacts / for main contacts 3
Operating current / at AC-1 / at 400 V / at 40 °C ambient temperature / rated value A 40
Operating current / at AC-1 / at 400 V / at 60 °C ambient temperature / rated value A 35
Operating current
o at AC-3 / at 400 V / rated value A 17
o at DC-1
o at 24 V / rated value A 35
o at DC-3 / at DC-5
o at 24 V / rated value A 20
o at DC-1
o at 24 V / rated value A 35
o at DC-3 / at DC-5
o at 24 V / rated value A 35
o at DC-1
o at 24 V / rated value A 35
o at DC-3 / at DC-5
o at 24 V / rated value A 35
Service power
o at AC-1 / at 400 V / rated value k 23
W
o at AC-3
Control circuit:
Design of activation of the operating mechanism conventional
Type of voltage / of the controlled supply voltage AC
Control supply voltage frequency
o 1 / rated value Hz 50
o 2 / rated value Hz 60
o at 60 Hz / for AC
o lagging switching 0
o leading switching 0
o at AC-15
o at 230 V A 6
o at 400 V A 3
o at DC-12
o at 60 V A 6
o at 110 V A 3
o at 220 V A 1
o at DC-13
o at 24 V A 10
o at 60 V A 2
o at 110 V A 1
o at 220 V A 0.3
Short-circuit:
Design of the fuse link
o for short-circuit protection of the auxiliary switch / required fuse gL/gG: 10 A
Installation/mounting/dimensions:
Type of mounting screw and snap-on mounting onto
35 mm standard mounting rail
according to DIN EN 50022
series installation Yes
Width m 45
m
Height m 85
m
Depth m 91
m
Distance, to be maintained, to earthed part / sidewards m 6
m
Connection type:
Design of the electrical connection
o for main current circuit screw-type terminals
last change: Oct 25, 2010