Exp. 3 Electro Pneumatics Control Technology
Exp. 3 Electro Pneumatics Control Technology
University Of Jordan
Faculty of Engineering & Technology
Mechanical Engineering Department
Control of Hydraulic & Pneumatic System Lab
Experiments No.3 Electro
pneumatics Control Technology
Objective: This exercises conveys basic knowledge and skills on setting up and
commissioning an electro pneumatic control using the example of a direct
electric activation of a single acting cylinder.
Pre-Lab
Pre-Lab: the required pneumatic circuit diagrams using the automation studio SW; show
the whole connections and components required for each circuit.
In the lab: Build your designs and verify their operation. sure that the pressure is 4 bars
and is connected correctly. Double check your connections before switching
the compressor on.
Aim:
This exercise demonstrates the control of a double-acting cylinder with an electrically
controlled, spring return 5/2 directional control valve without the use of a relay.
List of equipment:
Description:
- (04) Double-acting cylinder, with annular solenoid
- (32) 5/2 directional control impulse valve, electrically controlled
- (37) Unit, 1 control switch, 2 push buttons
- (50) Power supply unit
- (42) Unit, electric manifold
- (01) Pneumatic air service unit
- (02) Compressed air distributor
Procedure
Connect the circuit shown in Figures 1 and 2.
Conclusion:
- The double-acting cylinder can be directly controlled by a ________________________.
- Start the system by pressing S1 momentarily assuming that the switch S0 is on , step what
the system do:
__________________________________________________________________
__________________________________________________________________
__________________________________________________________________
__________________________________________________________________
- What the initial or center position for (32) 5/2 directional control impulse valve,
electrically controlled
_________________________________________________________________________
_________________________________________________________________________
List of equipment:
Description:
- (04) Double-acting cylinder, with annular solenoid
- (32) 5/2 directional control impulse valve, electrically controlled
- (37) Unit, 1 control switch, 2 push buttons
- (34) Relay unit 4 changeover contacts
- (50) Power supply unit
- (42) Unit, electric manifold
- (01) Pneumatic air service unit
- (02) Compressed air distributor
Procedure
Connect the circuit shown in Figures 3 and 4.
Conclusion:
- Start the system by pressing S1 momentarily, step what the system do:
__________________________________________________________________
__________________________________________________________________
Aim:
This exercise the various possible circuits with latching (storage circuits) in relay
technology are demonstrated.
List of equipment:
Description:
- (04) Double-acting cylinder, with annular solenoid
- (31) 5/2 directional control impulse valve, electrically controlled, spring return
- (37) Unit, 1 control switch, 2 push buttons
- (34) Relay unit 4 changeover contacts
- (50) Power supply unit
- (42) Unit, electric manifold
- (01) Pneumatic air service unit
- (02) Compressed air distributor
Procedure
A. Connect the circuit shown in Figures 5 and 6.
Conclusion:
- Start the system by pressing S1 momentarily assuming that the switch S0 is on , step what
the system do:
__________________________________________________________________
__________________________________________________________________
__________________________________________________________________
__________________________________________________________________
Procedure
B. Connect the circuit shown in Figures 7.
Conclusion:
- Start the system by pressing S1 momentarily assuming that the switch S0 is on , step what
the system do:
__________________________________________________________________
__________________________________________________________________
__________________________________________________________________
__________________________________________________________________
Aim:
Cylinder switches and an electrically controlled 5/2 directional control impulse valve are
used in this displacement- dependent control of a double-acting cylinder.
List of equipment:
Description:
- (04) Double-acting cylinder, with annular solenoid
- (32) 5/2 directional control impulse valve, electrically controlled
- (15) one way flow control valve
- (37) Unit, 1 control switch, 2 push buttons
- (34) Relay unit 4 changeover contacts
- (38) Cylinder switches
- (50) Power supply unit
- (42) Unit, electric manifold
- (01) Pneumatic air service unit
- (02) Compressed air distributor
Procedure
A. Connect the circuit shown in Figures 8 and 9.
Conclusion:
- Start the system by pressing S0 momentarily , step what the system do:
__________________________________________________________________
__________________________________________________________________
__________________________________________________________________
__________________________________________________________________
- Design the functional diagram (stroke-time diagram) for the cylinder and the 5/2
directional control valve.
List of equipment:
Description:
- (04) Double-acting cylinder, with annular solenoid
- (32) 5/2 directional control impulse valve, electrically controlled
- (15) one way flow control valve
- (37) Unit, 1 control switch, 2 push buttons
- (34) Relay unit 4 changeover contacts
- (38) Cylinder switches
- (50) Power supply unit
- (42) Unit, electric manifold
- (01) Pneumatic air service unit
- (02) Compressed air distributor
Procedure:
- After actuating control limit switch S1, the piston rod of a double-acting cylinder (Z1) is
extends and after reaching the front end position, the piston of a double-acting cylinder
(Z2) is extends and after reaching the front end position the piston of a double acting
cylinder ( Z1 ) retracts when fully retract cylinder ( Z1 ) the piston of cylinder ( Z1 )
retracts.
- This Procedure repeats itself as long as switch S1 remains ON.
- Additional requirements: add two push button S0 and S2, after briefly actuating S0 the
cylinder start the process, after actuating S2 the cylinder stop.
- It should be possible to reduce the extension speed.
- Drawing the circuit diagram with symbols and port symbols
- Drawing the Electric circuit diagram with symbols and port symbols.