0% found this document useful (0 votes)
2K views

Calculation of Maximum Discharge Rate

This document provides information about the maximum rate of discharge for untreated sewage from the M/T Tanker ship. It lists the ship details including dimensions and service speed. The theoretical maximum discharge rate is 70.52 m3/h but may be exceeded by 20% when measured hourly. The permissible discharge rate is reduced based on draft and speed, with a table providing the discharge rates for combinations of speeds between 4-16 knots and drafts between 8-14 meters.

Uploaded by

ch3g44
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
2K views

Calculation of Maximum Discharge Rate

This document provides information about the maximum rate of discharge for untreated sewage from the M/T Tanker ship. It lists the ship details including dimensions and service speed. The theoretical maximum discharge rate is 70.52 m3/h but may be exceeded by 20% when measured hourly. The permissible discharge rate is reduced based on draft and speed, with a table providing the discharge rates for combinations of speeds between 4-16 knots and drafts between 8-14 meters.

Uploaded by

ch3g44
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
You are on page 1/ 1

MAXIMUM RATE OF DISCHARGE OF UNTREATED SEWAGE

IN ACCORDANCE WITH RESOLUTION MEPC.157(55)

SHIP NAME: M/T TANKER


DNV ID: 12345
Breadth: 34.00 m
Max. Summer draft: 14.00 m
Max. Service speed: 16.0 kts
Theoretical max rate: 70.52 m3/h

The calculated discharge rate refers to the average rate as calculated over any 24hour period, or the period
of discharge if that is less, and may be exceeded by no more than 20% when measured on an hourly basis.

NB! The premissible rate of discharge is reduced at reduced draft and/or speed. See table below:

DISCHARGE RATE (m3/h)


SPEED (kt) 4 6 8 10 12 14 16
DRAFT (m)
8 10.07 15.11 20.15 25.19 30.22 35.26 40.30
9 11.33 17.00 22.67 28.34 34.00 39.67 45.34
10 12.59 18.89 25.19 31.48 37.78 44.08 50.37
11 13.85 20.78 27.71 34.63 41.56 48.49 55.41
12 15.11 22.67 30.22 37.78 45.34 52.89 60.45
13 16.37 24.56 32.74 40.93 49.12 57.30 65.49
14 17.63 26.45 35.26 44.08 52.89 61.71 70.52