0% found this document useful (0 votes)
60 views

Parameters For Mix Design M40

1. The document provides parameters for a concrete mix design with a target strength of M40. 2. The mix uses OPC cement grade 43, with a water-cement ratio of 0.4 and minimum cement content of 400kg/m3. 3. Calculations determine the fine aggregate content as 660kg, coarse aggregate (20mm) as 701kg, and coarse aggregate (10mm) as 467kg. The mix proportions are 0.4:1:1.65:2.92 for water:cement:fine aggregate:coarse aggregate.

Uploaded by

Abhijit Erande
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
60 views

Parameters For Mix Design M40

1. The document provides parameters for a concrete mix design with a target strength of M40. 2. The mix uses OPC cement grade 43, with a water-cement ratio of 0.4 and minimum cement content of 400kg/m3. 3. Calculations determine the fine aggregate content as 660kg, coarse aggregate (20mm) as 701kg, and coarse aggregate (10mm) as 467kg. The mix proportions are 0.4:1:1.65:2.92 for water:cement:fine aggregate:coarse aggregate.

Uploaded by

Abhijit Erande
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
You are on page 1/ 3

Parameters for mix design M40

Grade Designation= M-40


Type of cement = O.P.C-43 grade
Brand of cement = Vikram ( Grasim )
Admixture = Fosroc ( Conplast SP 430 G8M )
Fine Aggregate = Zone-II
Sp. Gravity Cement = 3.15
Fine Aggregate = 2.61
Coarse Aggregate (20mm) = 2.65
Coarse Aggregate (10mm) = 2.66
Minimum Cement (As per contract) = 400 kg / m3
Maximum water cement ratio (As per contract) = 0.45
Mix Calculation: -
1. Target Mean Strength = 40 + (5 X 1.65) = 48.25 Mpa

2. Selection of water cement ratio:-


Assume water cement ratio = 0.4
3. Calculation of cement content: -
Assume cement content 400 kg / m3
(As per contract Minimum cement content 400 kg / m3)
4. Calculation of water: -
400 X 0.4 = 160 kg Which is less than 186 kg (As per Table No. 4, IS: 10262)
Hence o.k.
5. Calculation for C.A. & F.A.: – As per IS : 10262 , Cl. No. 3.5.1

V = [ W + (C/Sc) + (1/p) . (fa/Sfa) ] x (1/1000)


V = [ W + (C/Sc) + {1/(1-p)} . (ca/Sca) ] x (1/1000)
Where V = absolute volume of fresh concrete, which is equal to gross volume (m 3) minus
the volume of entrapped air ,

W = mass of water ( kg ) per m3 of concrete ,

C = mass of cement ( kg ) per m3 of concrete ,


Sc = specific gravity of cement,
(p) = Ratio of fine aggregate to total aggregate by absolute volume ,
(fa) , (ca) = total mass of fine aggregate and coarse aggregate (kg) per m 3 of
Concrete respectively, and
Sfa , Sca = specific gravities of saturated surface dry fine aggregate and Coarse aggregate
respectively.

As per Table No. 3 , IS-10262, for 20mm maximum size entrapped air is 2% .

Assume F.A. by % of volume of total aggregate = 36.5 %

0.98 = [ 160 + ( 400 / 3.15 ) + ( 1 / 0.365 ) ( Fa / 2.61 )] ( 1 /1000 )

=> Fa = 660.2 kg

Say Fa = 660 kg.

0.98 = [ 160 + ( 400 / 3.15 ) + ( 1 / 0.635 ) ( Ca / 2.655 )] ( 1 /1000 )

=> Ca = 1168.37 kg.

Say Ca = 1168 kg.

Considering 20 mm : 10mm = 0.6 : 0.4

20mm = 701 kg .
10mm = 467 kg .

Hence Mix details per m3


Cement = 400 kg
Water = 160 kg
Fine aggregate = 660 kg
Coarse aggregate 20 mm = 701 kg
Coarse aggregate 10 mm = 467 kg
Admixture = 0.6 % by weight of cement = 2.4 kg.
Recron 3S = 900 gm
Water: cement: F.A.: C.A. = 0.4: 1: 1.65: 2.92
Observation: -
A. Mix was cohesive and homogeneous.
B. Slump = 110mm
C. No. of cube casted = 12 Nos.
7 days average compressive strength = 51.26 MPa.
28 days average compressive strength = 62.96 MPa which is greater than 48.25MPa
Hence the mix is accepted.

You might also like