0% found this document useful (0 votes)
24 views

Solution:: η Q Q Q Q s

1) The francis turbine model operates at 6.5m head, 206.5 l/s flow, 750 rpm, and 12 kW power with 98% efficiency. Its dimensional specific speed is 294.73 rpm. 2) Under 26m head, flow is calculated as 413 l/s, speed as 1500 rpm, and power as 96 kW. 3) For an 8-pole generator at 65m head, power is calculated as 600W and scale as prototype to model is 1.

Uploaded by

aaguriondo
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
24 views

Solution:: η Q Q Q Q s

1) The francis turbine model operates at 6.5m head, 206.5 l/s flow, 750 rpm, and 12 kW power with 98% efficiency. Its dimensional specific speed is 294.73 rpm. 2) Under 26m head, flow is calculated as 413 l/s, speed as 1500 rpm, and power as 96 kW. 3) For an 8-pole generator at 65m head, power is calculated as 600W and scale as prototype to model is 1.

Uploaded by

aaguriondo
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
You are on page 1/ 2

3. (Problem 3.

9) A francis turbine model, in a test bench, gives, in optimum operating


efficiency conditions, the following results:

Hn = 6.5 m Q = 206.5 l/s N = 750 rpm Pr = 12 kW ηo = 0.98

a) Calculate the overall efficiency and dimensional specific speed (Camerer


number).
b) Under optimal conditions, calculate Q, N and Pr if we place the model in a net
head of 26.
c) If 8 is the number of poles of the prototype turbine generator and the available
net head is 65 m, calculate Pr, and the scale λ, to operate in homologous way to
the previous cases.

SOLUTION:

a) As it is said, the Francis turbine works in optimum operating efficiency


conditions, what is the same as saying that the Volumetric Efficiency (ηv) is 1.

Taking this into account, and knowing that the Volumetric Efficiency is:
QU
ηV =
QT
We can deduce that the useful flow rate has the same value that the total:
QU =QT =206.5 l/s=0.2065 m3 /s

Knowing that the mechanical efficiency is ηO =0.98 the only missing data for
obtaining the overall efficiency is the hydraulic efficiency, which could be obtained
with the following relationship:

HE
ηh =
Hn

In which Hn is already known and He can be found out with the following
relationship:

HR H 5.93
ηO = ; H E= R = =6.09 m
HE ηO 0.98

Once we have obtained the effective head, we can calculate the effective power
using the equation below:

Pe =ρ·g·Q· H e =103 · 9.8· 206.5 ·10−3 · 6.05=12243.385 W =12.24 kW

Finally, with the effective power, we are able to obtain the Camerer number (ns):

12243.38
n S=
N· √ Pe
5
=
750 ·
√ 736
5
=294.73 r . p . m.
4 4
Hn (6.5)
b) As it is said that the turbine is working in optimum conditions in all the
headlands, we can use both the Camerer and the Brawer numbers in all
headlands.

With the Brawer number, we can find a relationship between the N and the Q:

N· √ Q 750 · √ 0.2065 N ' · √Q'


n S= 3
= 3
=83.72; 83.72= 3
4 4 4
Hn ( 6.5 ) 26

N ' · √ Q' =963.96

And now, once we have this relationship we can obtain both the Q and the N:
3
Q' Q Q' · √Q ' Q Q2 0.2065
= ; = ; =
N N 936.96 N 936.96 750
'

Q' =413l/ s
N ' =1500 r . p . m.

HE
ηH= ; H E =η H · H N =0.93 · 26=24.2 m
HN

HR
ηO = ; H R=ηO · H E=0.98· 24.2=23.72 m
HE

Pr =ρ·g·Q U · H r =1000 · 9.8· 0.413 · 23.72=96004.328 W =96 kW

c) As we are given the number of poles and the electric frequency in Europe is
50Hz, the rotational speed is:

60 ·50
N P= =375 r . p . m .
8

With the rotational speed we can obtain prototype real power with the following
relationship:
Pm Pp P P
5 3
= 5 3
; m3 = r p3
ρ· D · ( N m ) ρ· D · ( N p ) N m ( N p )

1200 · 375
Pr p = =600 W
750