Summery Load-400 KN SIZE: - Width: - 200 Depth: - 400 BAR: - 6 14

Six columns (C1-C6) were designed to carry various loads between 400-800 kN. The columns have widths of 200 mm, depths between 400-700 mm, and an effective length of 2700 mm. Reinforcement areas between 6-14 bars of diameter 14 or 16 mm were calculated and provided to support the loads, meeting minimum requirements. Load, size, reinforcement details are provided for each column.

Uploaded by

Bijumon Bkn
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
129 views3 pages

Summery Load-400 KN SIZE: - Width: - 200 Depth: - 400 BAR: - 6 14

Six columns (C1-C6) were designed to carry various loads between 400-800 kN. The columns have widths of 200 mm, depths between 400-700 mm, and an effective length of 2700 mm. Reinforcement areas between 6-14 bars of diameter 14 or 16 mm were calculated and provided to support the loads, meeting minimum requirements. Load, size, reinforcement details are provided for each column.

Uploaded by

Bijumon Bkn
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
You are on page 1/ 3

DESIGN OF LONG COLUMN COL.

N0:- C1

Load on a column P= 400 KN SUMMERY


Width of column b= 200 mm LOAD- 400 KN
Depth of column D= 400 mm SIZE:-
Effective length of column Leff= 2700 mm WIDTH:- 200
Ratio Leff / b <12 short column 13.5 >12 DEPTH:- 400
Reduction factor Cr=1.25-(Leff./48/b) Cr= 0.969 BAR:- 6 14
Charecteristic strength of reinfo. fy= 415 N/mm2
Carecteristic strength of concrete fck= 20 N/mm2
Area of concrete Ac= b x D Ac= 80000 sqmm
Ultimate load on column 1.5xP Pu= 600 KN
Net load on col Pu(net)= Pu/Cr Pu(net)= 619 KN
Pu(Net) = 0.4*fck*Ac +0.67*fy*Asc
Area of longitudinal steel required
Asc= (Pu - 0.4*fck*Ac)/ (0.67*fy) Asc= -76 sqmm
check for min. reinforcement
Asc (min.) = 0.004*b*D/100 Asc(min) = 320 sqmm
PROVIDE 6 BAR 14 Asc(pro) = 923 sqmm
AREA PROVIDED OK

DESIGN OF LONG COLUMN COL. N0:- C2

Load on a column P= 500 KN SUMMERY


Width of column b= 200 mm LOAD- 500 KN
Depth of column D= 500 mm SIZE:-
Effective length of column Leff= 2700 mm WIDTH:- 200
Ratio Leff / b <12 short column 13.5 >12 DEPTH:- 500
Reduction factor Cr=1.25-(Leff./48/b) Cr= 0.969 BAR:- 8 14
Charecteristic strength of reinfo. fy= 415 N/mm2
Carecteristic strength of concrete fck= 20 N/mm2
Area of concrete Ac= b x D Ac= 100000 sqmm
Ultimate load on column 1.5xP Pu= 750 KN
Net load on col Pu(net)= Pu/Cr Pu(net)= 774 KN
Pu(Net) = 0.4*fck*Ac +0.67*fy*Asc
Area of longitudinal steel required
Asc= (Pu - 0.4*fck*Ac)/ (0.67*fy) Asc= -94 sqmm
check for min. reinforcement
Asc (min.) = 0.004*b*D/100 Asc(min) = 400 sqmm
PROVIDE 8 BAR 14 Asc(pro) = 1231 sqmm
AREA PROVIDED OK

42
DESIGN OF LONG COLUMN COL. N0:- C3

Load on a column P= 575 KN SUMMERY


Width of column b= 200 mm LOAD- 575 KN
Depth of column D= 500 mm SIZE:-
Effective length of column Leff= 2700 mm WIDTH:- 200
Ratio Leff / b <12 short column 13.5 >12 DEPTH:- 500
Reduction factor Cr=1.25-(Leff./48/b) Cr= 0.969 BAR:- 10 14
Charecteristic strength of reinfo. fy= 415 N/mm2
Carecteristic strength of concrete fck= 20 N/mm2
Area of concrete Ac= b x D Ac= 100000 sqmm
Ultimate load on column 1.5xP Pu= 862.5 KN
Net load on col Pu(net)= Pu/Cr Pu(net)= 890 KN
Pu(Net) = 0.4*fck*Ac +0.67*fy*Asc
Area of longitudinal steel required
Asc= (Pu - 0.4*fck*Ac)/ (0.67*fy) Asc= 324 sqmm
check for min. reinforcement
Asc (min.) = 0.004*b*D/100 Asc(min) = 400 sqmm
PROVIDE 10 BAR 14 Asc(pro) = 1539 sqmm
AREA PROVIDED OK

DESIGN OF LONG COLUMN COL. N0:- C4

Load on a column P= 680 KN SUMMERY


Width of column b= 200 mm LOAD- 680 KN
Depth of column D= 600 mm SIZE:-
Effective length of column Leff= 2700 mm WIDTH:- 200
Ratio Leff / b <12 short column 13.5 >12 DEPTH:- 600
Reduction factor Cr=1.25-(Leff./48/b) Cr= 0.969 BAR:- 12 14
Charecteristic strength of reinfo. fy= 415 N/mm2
Carecteristic strength of concrete fck= 20 N/mm2
Area of concrete Ac= b x D Ac= 120000 sqmm
Ultimate load on column 1.5xP Pu= 1020 KN
Net load on col Pu(net)= Pu/Cr Pu(net)= 1053 KN
Pu(Net) = 0.4*fck*Ac +0.67*fy*Asc
Area of longitudinal steel required
Asc= (Pu - 0.4*fck*Ac)/ (0.67*fy) Asc= 334 sqmm
check for min. reinforcement
Asc (min.) = 0.004*b*D/100 Asc(min) = 480 sqmm
PROVIDE 12 BAR 14 Asc(pro) = 1846 sqmm
AREA PROVIDED OK
43
DESIGN OF LONG COLUMN COL. N0:- C5

Load on a column P= 800 KN SUMMERY


Width of column b= 200 mm LOAD- 800 KN
Depth of column D= 700 mm SIZE:-
Effective length of column Leff= 2700 mm WIDTH:- 200
Ratio Leff / b <12 short column 13.5 >12 DEPTH:- 700
Reduction factor Cr=1.25-(Leff./48/b) Cr= 0.969 BAR:- 12 16
Charecteristic strength of reinfo. fy= 415 N/mm2
Carecteristic strength of concrete fck= 20 N/mm2
Area of concrete Ac= b x D Ac= 140000 sqmm
Ultimate load on column 1.5xP Pu= 1200 KN
Net load on col Pu(net)= Pu/Cr Pu(net)= 1238 KN
Pu(Net) = 0.4*fck*Ac +0.67*fy*Asc
Area of longitudinal steel required
Asc= (Pu - 0.4*fck*Ac)/ (0.67*fy) Asc= 424 sqmm
check for min. reinforcement
Asc (min.) = 0.004*b*D/100 Asc(min) = 560 sqmm
PROVIDE 12 BAR 16 Asc(pro) = 2412 sqmm
AREA PROVIDED OK

DESIGN OF LONG COLUMN COL. N0:- C6

Load on a column P= 800 KN SUMMERY


Width of column b= 200 mm LOAD- 800 KN
Depth of column D= 700 mm SIZE:-
Effective length of column Leff= 2700 mm WIDTH:- 200
Ratio Leff / b <12 short column 13.5 >12 DEPTH:- 700
Reduction factor Cr=1.25-(Leff./48/b) Cr= 0.969 BAR:- 14 16
Charecteristic strength of reinfo. fy= 415 N/mm2
Carecteristic strength of concrete fck= 20 N/mm2
Area of concrete Ac= b x D Ac= 140000 sqmm
Ultimate load on column 1.5xP Pu= 1200 KN
Net load on col Pu(net)= Pu/Cr Pu(net)= 1238 KN
Pu(Net) = 0.4*fck*Ac +0.67*fy*Asc
Area of longitudinal steel required
Asc= (Pu - 0.4*fck*Ac)/ (0.67*fy) Asc= 424 sqmm
check for min. reinforcement
Asc (min.) = 0.004*b*D/100 Asc(min) = 560 sqmm
PROVIDE 14 BAR 16 Asc(pro) = 2813 sqmm
AREA PROVIDED OK
44