This document provides specifications for an inductive proximity sensor model E2E-X5MY15 2M including its ratings and performance, sensing method and distance, power supply and output details, operating conditions and temperature/voltage influence, insulation/dielectric strength, vibration/shock resistance, degree of protection, applicable standards and certifications, connection method, materials, and accessories. The sensor uses an inductive sensing method with a sensing distance of 5-10mm and differential of 10% of sensing distance for ferrous metal targets.

Uploaded by

Cyboss
Copyright
© Attribution Non-Commercial (BY-NC)
Available Formats
Download as DOC, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
47 views

Omron

This document provides specifications for an inductive proximity sensor model E2E-X5MY15 2M including its ratings and performance, sensing method and distance, power supply and output details, operating conditions and temperature/voltage influence, insulation/dielectric strength, vibration/shock resistance, degree of protection, applicable standards and certifications, connection method, materials, and accessories. The sensor uses an inductive sensing method with a sensing distance of 5-10mm and differential of 10% of sensing distance for ferrous metal targets.

Uploaded by

Cyboss
Copyright
© Attribution Non-Commercial (BY-NC)
Available Formats
Download as DOC, PDF, TXT or read online on Scribd
You are on page 1/ 2

E2E-X5MY15 2M

Ratings / Performance
Shield Unshielded
Cylinder type sensing head size M12
Sensing method Inductive type
Sensing distance 5 mm -10% to +10%
Setting distance 0 to 4 mm
Differential distance 10% Max. of sensing distance
Sensing object Ferrous metal (Sensitivity lowers with non-ferrous metals.)
Standard sensing object Iron 15*15*1mm
Response frequency AC: 25 Hz (average)
Power supply voltage 24 to 240 V
Operating voltage range 20 to 264 VAC
Leakage current 1.7 mA Max.
Control output (Output type) AC 2-wire models
Control output (Switching
5 to 200 mA
capacity)
Indicator Operation indicator(red)
Operation mode NO
Protective circuit Surge suppressor
Standard or Different frequency Different frequency
Operating: -40 to 85 CEL
Ambient temperature Storage: -40 to 85 CEL
(with no icing or condensation)
Operating: 35 to 95 %RH
Ambient humidity Storage: 35 to 95 %RH
(with no condensation)
+-10% Max. of sensing distance in temperature range of
-25 to +70CEL
Temperature influence +-15% Max. of sensing distance in temperature range of
-40 to +85CEL
(As the basis for sensing distance of 23CEL)
+-1% Max. of sensing distance in rated voltage range +-
Voltage influence 15%. (As the basis for sensing distance at standard power
voltage)
50 M OHM Min. at 500VDC between charged parts and
Insulation resistance
the case
4000 VAC 50/60 Hz for 1 minute between charged parts
Dielectric strength
and the case
10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in
Vibration resistance
X, Y, and Z directions
Shock resistance 1000m/s2 for 10 times each in X, Y, and Z directions
IEC60529: IP67
Degree of protection
Company standard: Oil-proof
Applicable standard (EC
EN60947-1
Directive (Low Voltage
EN60947-5-2
Directive))
EMI: EN60947-5-2
Emission Enclosure: CISPR11 Group 1 classA
EMS: EN60947-5-2
Applicable standard (EC Immunity ESD: IEC61000-4-2
Directive (EMC Directive)) Immunity RF-interference: IEC61000-4-3
Immunity Conducted Disturbance: IEC61000-4-6
Immunity Burst: IEC61000-4-4
CE marking: Equipped
Applicable standard (CCC
Equipped
mark)
Connection method Pre-wired models (Cable length: 2 m)
Weight (Packed state) approx. 70 g
Material (case) Brass nickel plating
Material (sensing surface) PBT
Material (clamping nuts) Brass nickel plating
Material (toothed washer) Iron zinc plating
Accessories Instruction manual