Object List - EPS V1
Object List - EPS V1
Page 1 of 47
How to use this document
This document describes the objects with attributes and methods which must be supported in order to
achieve interoperability at metering point with installed PLC node.
Object name IC version Logical Name Access Rights for all three clients
defined
1 attribute_1 type of attr._1 default value of attr._1 access_rights to attr._1
2 attribute_2 type of attr._2 default value of attr._2 access_rights to attr._2
The default values are set only where necessary to achieve interoperability.
IC Interface Class; used to identify the COSEM interface class and its version
--/S/G/A/GS Access rights definition; “--“ for no access, “S” for Set only, “G” for Get only, “A” for
action and “GS” for Get and Set access
Page 2 of 47
Abstract objects
1
Change of password is proprietary and has to be documented by every meter manufacturer
Page 3 of 47
16]
Page 4 of 47
(Client 16/102/1)
1 logical_name octet-string[6] 0000600104FF -/-/G
2 value octet- -/-/GS
string[0...48]
Clock
Page 5 of 47
Time Of Use
Billing reset
Predefined Scripts - MDI reset / end of billing IC9-0 0-0:10.0.1.255 Access Rights T13
period (Client 16/102/1)
1 logical_name octet-string[6] 00000A0001FF -/-/G
2 scripts script -- -/-/-
Page 6 of 47
1 execute long-unsigned 1
-/-/A
2
Every day or every month
Page 7 of 47
6 sort_object capture_object_definiti none -/-/G
on
7 entries_in_use double-long-unsigned -/-/G
8 profile_entries double-long-unsigned ≥13 -/-/G
Disconnection
Page 8 of 47
1 execute long-unsigned -/-/A
Page 9 of 47
9 emergency_profile_group_id_list array -/-/GS
10 emergency_profile_active boolean -/-/GS
11 actions action_set {...0- -/-/G
0:10.0.106.255…}
Average Instantaneous Import Power (+A) IC3-0 1-0:1.24.1.255 Access Rights T20
(Client 16/102/1)
1 logical_name octet-string[6] 0100011801FF -/-/G
2 value double-long- -/-/G
unsigned
3 scaler_unit scal_unit_type {0,27} -/-/G
1 reset -/-/A
3
Error bit mask and alarm bit mask as per dsmr 2.31
Page 10 of 47
1 logical_name octet-string[6] 0000616100FF -/-/G
2 value double-long- -/-/GS
unsigned
Event logs4
Event Object - Standard Event Log IC1-0 0-0:96.11.0.255 Access Rights T25
(Client 16/102/1)
1 logical_name octet-string[6] 0000600B00FF -/-/G
2 value enum -/-/G
4
List of events as per dsmr 2.31
Page 11 of 47
1 logical_name octet-string[6] 0000636200FF -/-/G
2 buffer array -/-/G
3 capture_objects array {8,0- -/-/G
0:1.0.0.255,2,0}
{0-
0:96.11.0.255,2,0}
4 capture_period double-long-unsigned 0 -/-/G
5 sort_method enum 1 -/-/G
6 sort_object capture_object_definiti none -/-/G
on
7 entries_in_use double-long-unsigned -/-/G
8 profile_entries double-long-unsigned ≥100 -/-/G
Event Object - Fraud Detection Log IC1-0 0-0:96.11.1.255 Access Rights T27
(Client 16/102/1)
1 logical_name octet-string[6] 0000600B01FF -/-/G
2 value enum -/-/G
Page 12 of 47
6 sort_object capture_object_definiti none -/-/G
on
7 entries_in_use double-long-unsigned -/-/G
8 profile_entries double-long-unsigned ≥30 -/-/G
}
4 capture_period double-long-unsigned 0 -/-/G
5 sort_method enum 1 -/-/G
6 sort_object capture_object_definiti none -/-/G
on
7 entries_in_use double-long-unsigned -/-/G
8 profile_entries double-long-unsigned ≥10 -/-/G
Page 13 of 47
1 reset integer -/-/A
Event Object - Power Quality Log IC1-0 0-0:96.11.4.255 Access Rights T32
(Client 16/102/1)
1 logical_name octet-string[6] 0000600B04FF -/-/G
2 value enum -/-/GS
Page 14 of 47
2 buffer array -/-/G
3 capture_objects array { -/-/G(S)
{8,0-
0:1.0.0.255,2,0};
{1,0-
0:96.11.5.255,2,0}
}
4 capture_period double-long-unsigned 0 -/-/G
5 sort_method enum 1 -/-/G
6 sort_object capture_object_definiti none -/-/G
on
7 entries_in_use double-long-unsigned -/-/G
8 profile_entries double-long-unsigned ≥100 -/-/G
1 reset -/-/A
Page 15 of 47
1 image_transfer_initiate structure -/-/A
2 image_block_transfer structure -/-/A
3 image_verify integer -/-/A
4 image_activate integer -/-/A
Page 16 of 47
Active firmware version signature IC1-0 1-0:0.2.8.255 Access Rights T38
(Client 16/102/1)
1 logical_name octet-string[6] 0100000208FF -/-/G
2 value octet- -/-/G
string[1…n]
Page 17 of 47
Reactive energy import (+R) IC3-0 1-0:3.8.0.255 Access Rights T43
(QI+QII) (Client 16/102/1)
1 logical_name octet-string[6] 0100030800FF -/-/G
2 value double-long- -/-/G
unsigned
3 scaler_unit scal_unit_type {0,32} -/-/G
Active energy import (+A) rate 1 IC3-0 1-0:1.8.1.255 Access Rights T54
(Client 16/102/1)
1 logical_name octet-string[6] 0100010801FF -/-/G
2 value double-long- -/-/G
unsigned
3 scaler_unit scal_unit_type {0,30} -/-/G
Active energy import (+A) rate 2 IC3-0 1-0:1.8.2.255 Access Rights T55
(Client 16/102/1)
1 logical_name octet-string[6] 0100010802FF -/-/G
Page 18 of 47
2 value double-long- -/-/G
unsigned
3 scaler_unit scal_unit_type {0,30} -/-/G
Active energy import (+A) rate 3 IC3-0 1-0:1.8.3.255 Access Rights T56
(Client 16/102/1)
1 logical_name octet-string[6] 0100010803FF -/-/G
2 value double-long- -/-/G
unsigned
3 scaler_unit scal_unit_type {0,30} -/-/G
Page 19 of 47
3 scaler_unit scal_unit_type {0,30} -/-/G
Page 20 of 47
Reactive energy (+R) rate 3 IC3-0 1-0:3.8.3.255 Access Rights
(Client 16/102/1)
1 logical_name octet-string[6] 0100030803FF -/-/G
2 value double-long-unsigned -/-/G
3 scaler_unit scal_unit_type {0,32} -/-/G
Page 21 of 47
2 value double-long-unsigned -/-/G
3 scaler_unit scal_unit_type {0,32} -/-/G
Demand registration
Demand Register 1 - Active energy import (+A) IC5-0 1-0:1.4.0.255 Access Rights T94
(Client 16/102/1)
1 logical_name octet-string[6] 0100010400FF -/-/G
2 current_average_value double-long- -/-/G
unsigned
3 last_average_value double-long- -/-/G
unsigned
4 scaler_unit scal_unit_type {0,27} -/-/G
5 status unsigned 0 -/-/G
6 capture_time octet-string -/-/G
7 start_time_current octet-string -/-/G
8 period double-long- 900 -/-/GS
unsigned
9 number_of_periods long-unsigned 1 -/-/GS
Page 22 of 47
Demand Register 2 - Active energy export (−A) IC5-0 1-0:2.4.0.255 Access Rights T95
(Client 16/102/1)
1 logical_name octet-string[6] 0100020400FF -/-/G
2 current_average_value double-long- -/-/G
unsigned
3 last_average_value double-long- -/-/G
unsigned
4 scaler_unit scal_unit_type {0,27} -/-/G
5 status unsigned 0 -/-/G
6 capture_time octet-string -/-/G
7 start_time_current octet-string -/-/G
8 period double-long- 900 -/-/GS
unsigned
9 number_of_periods long-unsigned 1 -/-/GS
Demand Register 3 - Reactive energy import (+R) IC5-0 1-0:3.4.0.255 Access Rights T96
(Client 16/102/1)
1 logical_name octet-string[6] 0100030400FF -/-/G
2 current_average_value double-long- -/-/G
unsigned
3 last_average_value double-long- -/-/G
unsigned
4 scaler_unit scal_unit_type {0,29} -/-/G
5 status unsigned 0 -/-/G
6 capture_time octet-string -/-/G
7 start_time_current octet-string -/-/G
8 period double-long- 900 -/-/GS
unsigned
9 number_of_periods long-unsigned 1 -/-/GS
Page 23 of 47
Demand Register 4 - Reactive energy export (-R) IC5-0 1-0:4.4.0.255 Access Rights T97
(Client 16/102/1)
1 logical_name octet-string[6] 0100040400FF -/-/G
2 current_average_value double-long- -/-/G
unsigned
3 last_average_value double-long- -/-/G
unsigned
4 scaler_unit scal_unit_type {0,29} -/-/G
5 status unsigned 0 -/-/G
6 capture_time octet-string -/-/G
7 start_time_current octet-string -/-/G
8 period double-long- 900 -/-/GS
unsigned
9 number_of_periods long-unsigned 1 -/-/GS
Maximum Demand Register 1 - Active energy IC4-0 1-0:1.6.0.255 Access Rights T106
import (+A) (Client 16/102/1)
1 logical_name octet-string[6] 0100010600FF -/-/G
2 value double-long- -/-/G
unsigned
3 scaler_unit scal_unit_type {1,27} -/-/G
4 status unsigned -/-/G
5 capture_time octet-string -/-/G
Maximum Demand Register 2 - Active energy import (+A) - IC4-0 1-0:1.6.1.255 Access Rights
rate 1 (Client 16/102/1)
1 logical_name octet-string[6] 0100010601FF -/-/G
2 value double-long-unsigned -/-/G
3 scaler_unit scal_unit_type {1,27} -/-/G
Page 24 of 47
4 status unsigned -/-/G
5 capture_time octet-string -/-/G
Maximum Demand Register 3 - Active energy import (+A) - IC4-0 1-0:1.6.2.255 Access Rights
rate 2 (Client 16/102/1)
1 logical_name octet-string[6] 0100010602FF -/-/G
2 value double-long-unsigned -/-/G
3 scaler_unit scal_unit_type {1,27} -/-/G
4 status unsigned -/-/G
5 capture_time octet-string -/-/G
Maximum Demand Register 4 - Active energy import (+A) - IC4-0 1-0:1.6.3.255 Access Rights
rate 3 (Client 16/102/1)
1 logical_name octet-string[6] 0100010603FF -/-/G
2 value double-long-unsigned -/-/G
3 scaler_unit scal_unit_type {1,27} -/-/G
4 status unsigned -/-/G
5 capture_time octet-string -/-/G
Maximum Demand Register 5 - Active energy import (+A) - IC4-0 1-0:1.6.4.255 Access Rights
rate 4 (Client 16/102/1)
1 logical_name octet-string[6] 0100010604FF -/-/G
2 value double-long-unsigned -/-/G
3 scaler_unit scal_unit_type {1,27} -/-/G
4 status unsigned -/-/G
5 capture_time octet-string -/-/G
Page 25 of 47
Maximum Demand Register 6 - Active energy export (−A) IC4-0 1-0:2.6.0.255 Access Rights
(Client 16/102/1)
1 logical_name octet-string[6] 0100020600FF -/-/G
2 value double-long-unsigned -/-/G
3 scaler_unit scal_unit_type {1,27} -/-/G
4 status unsigned -/-/G
5 capture_time octet-string -/-/G
Maximum Demand Register 7 - Active energy export (−A) - IC4-0 1-0:2.6.1.255 Access Rights
rate 1 (Client 16/102/1)
1 logical_name octet-string[6] 0100020601FF -/-/G
2 value double-long-unsigned -/-/G
3 scaler_unit scal_unit_type {1,27} -/-/G
4 status unsigned -/-/G
5 capture_time octet-string -/-/G
Maximum Demand Register 8 - Active energy export (−A) - IC4-0 1-0:2.6.2.255 Access Rights
rate 2 (Client 16/102/1)
1 logical_name octet-string[6] 0100020602FF -/-/G
2 value double-long-unsigned -/-/G
3 scaler_unit scal_unit_type {1,27} -/-/G
4 status unsigned -/-/G
5 capture_time octet-string -/-/G
Maximum Demand Register 9 - Active energy export (−A) - IC4-0 1-0:2.6.3.255 Access Rights
rate 3 (Client 16/102/1)
1 logical_name octet-string[6] 0100020603FF -/-/G
2 value double-long-unsigned -/-/G
Page 26 of 47
3 scaler_unit scal_unit_type {1,27} -/-/G
4 status unsigned -/-/G
5 capture_time octet-string -/-/G
Maximum Demand Register 10 - Active energy export (−A) - IC4-0 1-0:2.6.4.255 Access Rights
rate 4 (Client 16/102/1)
1 logical_name octet-string[6] 0100020604FF -/-/G
2 value double-long-unsigned -/-/G
3 scaler_unit scal_unit_type {1,27} -/-/G
4 status unsigned -/-/G
5 capture_time octet-string -/-/G
Maximum Demand Register 11 - Reactive energy import (+R) IC4-0 1-0:3.6.0.255 Access Rights
(Client 16/102/1)
1 logical_name octet-string[6] 0100030600FF -/-/G
2 value double-long-unsigned -/-/G
3 scaler_unit scal_unit_type {1,29} -/-/G
4 status unsigned -/-/G
5 capture_time octet-string -/-/G
Maximum Demand Register 12 - Reactive energy import (+R) - IC4-0 1-0:3.6.1.255 Access Rights
rate 1 (Client 16/102/1)
1 logical_name octet-string[6] 0100030601FF -/-/G
2 value double-long-unsigned -/-/G
3 scaler_unit scal_unit_type {1,29} -/-/G
4 status unsigned -/-/G
5 capture_time octet-string -/-/G
Page 27 of 47
Maximum Demand Register 13 - Reactive energy import (+R) - IC4-0 1-0:3.6.2.255 Access Rights
rate 2 (Client 16/102/1)
1 logical_name octet-string[6] 0100030602FF -/-/G
2 value double-long-unsigned -/-/G
3 scaler_unit scal_unit_type {1,29} -/-/G
4 status unsigned -/-/G
5 capture_time octet-string -/-/G
Maximum Demand Register 14 - Reactive energy import (+R) - IC4-0 1-0:3.6.3.255 Access Rights
rate 3 (Client 16/102/1)
1 logical_name octet-string[6] 0100030603FF -/-/G
2 value double-long-unsigned -/-/G
3 scaler_unit scal_unit_type {1,29} -/-/G
4 status unsigned -/-/G
5 capture_time octet-string -/-/G
Maximum Demand Register 15 - Reactive energy import (+R) - IC4-0 1-0:3.6.4.255 Access Rights
rate 4 (Client 16/102/1)
1 logical_name octet-string[6] 0100030604FF -/-/G
2 value double-long-unsigned -/-/G
3 scaler_unit scal_unit_type {1,29} -/-/G
4 status unsigned -/-/G
5 capture_time octet-string -/-/G
Maximum Demand Register 16 - Reactive energy export (-R) IC4-0 1-0:4.6.0.255 Access Rights
(Client 16/102/1)
1 logical_name octet-string[6] 0100040600FF -/-/G
2 value double-long-unsigned -/-/G
Page 28 of 47
3 scaler_unit scal_unit_type {1,29} -/-/G
4 status unsigned -/-/G
5 capture_time octet-string -/-/G
Maximum Demand Register 17 - Reactive energy export (-R) - IC4-0 1-0:4.6.1.255 Access Rights
rate 1 (Client 16/102/1)
1 logical_name octet-string[6] 0100040601FF -/-/G
2 value double-long-unsigned -/-/G
3 scaler_unit scal_unit_type {1,29} -/-/G
4 status unsigned -/-/G
5 capture_time octet-string -/-/G
Maximum Demand Register 18 - Reactive energy export (-R) - IC4-0 1-0:4.6.2.255 Access Rights
rate 2 (Client 16/102/1)
1 logical_name octet-string[6] 0100040602FF -/-/G
2 value double-long-unsigned -/-/G
3 scaler_unit scal_unit_type {1,29} -/-/G
4 status unsigned -/-/G
5 capture_time octet-string -/-/G
Maximum Demand Register 19 - Reactive energy export (-R) - IC4-0 1-0:4.6.3.255 Access Rights
rate 3 (Client 16/102/1)
1 logical_name octet-string[6] 0100040603FF -/-/G
2 value double-long-unsigned -/-/G
3 scaler_unit scal_unit_type {1,29} -/-/G
4 status unsigned -/-/G
5 capture_time octet-string -/-/G
Page 29 of 47
Maximum Demand Register 20 - Reactive energy IC4-0 1-0:4.6.4.255 Access Rights T124
export (-R) - rate 4 (Client 16/102/1)
1 logical_name octet-string[6] 0100040604FF -/-/G
2 value double-long- -/-/G
unsigned
3 scaler_unit scal_unit_type {1,29} -/-/G
4 status unsigned -/-/G
5 capture_time octet-string -/-/G
Profiles
Profile status - Load profile with period 1 IC1-0 0-0:96.10.1.255 Access Rights T135
(Client 16/102/1)
1 logical_name octet-string[6] 0000600A01FF -/-/G
2 status unsigned -/-/G
5
Min period 15 min, max 60 min
Page 30 of 47
6 sort_object capture_object_definiti {8,0-0:1.0.0.255,2,0} -/-/G
on
7 entries_in_use double-long-unsigned -/-/G
8 profile_entries double-long-unsigned ≥960 -/-/G
1 reset -/-/A
Profile status - Load profile with period 2 IC1-0 0-0:96.10.2.255 Access Rights
(Client 16/102/1)
1 logical_name octet-string[6] 0000600A02FF -/-/G
2 status unsigned -/-/G
Page 31 of 47
1 reset -/-/A
Power quality
Number of power failures in any phase; total IC1-0 0-0:96.7.21.255 Access Rights T139
number of power failures (Client 16/102/1)
1 logical_name octet-string[6] 0000600715FF -/-/G
2 value long-unsigned -/-/G
Number of long power failures in any phase IC1-0 0-0:96.7.9.255 Access Rights T140
(Client 16/102/1)
1 logical_name octet-string[6] 0000600709FF -/-/G
2 value long-unsigned -/-/G
Time threshold for long power failure IC3-0 0-0:96.7.20.255 Access Rights T141
(Client 16/102/1)
1 logical_name octet-string[6] 0000600714FF -/-/G
2 value long-unsigned 180 -/S/GS
3 scaler_unit scal_unit_type {0,7} -/-/G
Duration of last long power failure in any phase IC3-0 0-0:96.7.19.255 Access Rights T142
(Client 16/102/1)
1 logical_name octet-string[6] 0000600713FF -/-/G
2 value long-unsigned -/-/GS
3 scaler_unit scal_unit_type {0,7} -/-/G
Page 32 of 47
Threshold for voltage sag IC3-0 1-0:12.31.0.255 Access Rights T143
(Client 16/102/1)
1 logical_name octet-string[6] 01000C1F00FF -/-/G
2 value long-unsigned 207 -/S/GS
3 scaler_unit scal_unit_type {0,35} -/-/G
Page 33 of 47
Threshold for voltage swell IC3-0 1-0:12.35.0.255 Access Rights T154
(Client 16/102/1)
1 logical_name octet-string[6] 01000C2300FF -/-/G
2 value long-unsigned 253 -/S/GS
3 scaler_unit scal_unit_type {0,35} -/-/G
Page 34 of 47
Instantaneous voltage L1 IC3-0 1-0:32.7.0.255 Access Rights T168
(Client 16/102/1)
1 logical_name octet-string[6] 0100200700FF -/-/G
2 value long-unsigned -/-/G
3 scaler_unit scal_unit_type {0,35} -/-/G
Page 35 of 47
2 value long-unsigned -/-/G
3 scaler_unit scal_unit_type {0,35} -/-/G
Instantaneous net frequency; any phase IC3-0 1-0:14.7.0.255 Access Rights T181
(Client 16/102/1)
1 logical_name octet-string[6] 01000E0700FF -/-/G
2 value long-unsigned -/-/G
3 scaler_unit scal_unit_type {0,44} -/-/G
Page 36 of 47
Last Average Power factor (+A/+VA) IC4-0 1-0:13.5.0.255 Access Rights T192
(Client 16/102/1)
1 logical_name octet-string[6] 01000D0500FF -/-/G
2 value long-unsigned -/-/G
3 scaler_unit scal_unit_type {-3,255} -/-/G
4 status unsigned -/-/G
5 capture_time octet-string -/-/G
6
Minimum power factor over billing reset period
Page 37 of 47
M-Bus client channel 1 IC72-1 0-1:24.1.0.255 Access Rights T196
(Client 16/102/1)
1 logical_name octet-string[6] 0001180100FF -/-/G
2 mbus_port_reference octet-string[6] {0-0:24.6.0.255} -/-/GS
M-Bus Value channel 1, instance 1 - {DIF_1,VIF_1} IC4-0 0-1:24.2.1.255 Access Rights T200
(Client 16/102/1)
Page 38 of 47
1 logical_name octet-string[6] 0001180201FF -/-/G
2 value double-long- -/-/G
unsigned
3 scaler_unit scal_unit_type {0,255} -/-/G
4 status long-unsigned -/-/G
5 capture_time octet-string -/-/G
1 reset -/-/A
1 reset -/-/A
1 reset -/-/A
Page 39 of 47
M-Bus Value channel 1, instance 4 - {DIF_4,VIF_4} IC4-0 0-1:24.2.4.255 Access Rights
(Client 16/102/1)
1 logical_name octet-string[6] 0001180204FF -/-/G
2 value double-long-unsigned -/-/G
3 scaler_unit scal_unit_type {0,255} -/-/G
4 status long-unsigned -/-/G
5 capture_time octet-string -/-/G
1 reset -/-/A
Profile status - M-Bus Master Load profile 1 IC1-0 0-1:96.10.3.255 Access Rights T224
(Client 16/102/1)
1 logical_name octet-string[6] 0001600A03FF -/-/G
2 status unsigned -/-/G
M-Bus Master Load profile for channel 1 IC7-1 0-1:24.3.0.255 Access Rights T228
(Client 16/102/1)
1 logical_name octet-string[6] 0001180300FF -/-/G
2 buffer array -/-/G
3 capture_objects array { -/-/GS
{8,0-
0:1.0.0.255,2,0},
{1, 0-
0:96.10.20.255,2,0},
{4, 0-
b:24.2.e.255,2,0}
}
4 capture_period double-long-unsigned 3600 -/-/GS
5 sort_method enum 1 -/-/G
Page 40 of 47
6 sort_object capture_object_definiti {8,0- -/-/G
on 0:1.0.0.255,2,0}
7 entries_in_use double-long-unsigned -/-/G
8 profile_entries double-long-unsigned ≥240 -/-/G
1 reset -/-/A
M-Bus Master Disconnect control object 1 IC70-0 0-1:24.4.0.255 Access Rights T232
(Client 16/102/1)
1 logical_name octet-string[6] 0001180400FF -/-/G
2 output_state boolean -/-/G
3 control_state enum -/-/G
4 control_mode enum -/S/GS
Event Objects - M-Bus Master Control logs 1 IC1-0 0-1:96.11.4.255 Access Rights T236
(Client 16/102/1)
1 logical_name octet-string[6] 0001600B04FF -/-/G
2 value enum -/-/G
Page 41 of 47
{1, 0-x:96.11.4.255,
2, 0}
4 capture_period double-long-unsigned 0 -/-/GS
5 sort_method enum 1 -/-/G
6 sort_object capture_object_definiti
on none -/-/G
7 entries_in_use double-long-unsigned -/-/G
8 profile_entries double-long-unsigned ≥10 -/-/G
1 reset -/-/A
Event Object - M-Bus Event Log IC1-0 0-0:96.11.3.255 Access Rights T244
(Client 16/102/1)
1 logical_name octet-string[6] 0000600B03FF -/-/G
2 value enum -/-/G
Page 42 of 47
8 profile_entries double-long-unsigned ≥10 -/-/G
1 reset -/-/A
IEC HDLC setup - HDLC Optical port IC23-1 0-0:22.0.0.255 Access Rights T247
(Client 16/102/1)
1 logical_name octet-string[6] 0000160000FF -/-/G
2 comm_speed enum 5 -/S/GS
3 window_size_transmit unsigned 1 -/S/GS
4 window_size_receive unsigned 1 -/S/GS
5 max_info_field_lenght_transmit unsigned 248 -/S/GS
6 max_info_field_lenght_receive unsigned 62 -/S/GS
7 inter_octet_time_out long-unsigned 150 -/S/GS
8 inactivity_time_out long-unsigned 120 -/S/GS
9 device_address long-unsigned 0 -/-/GS
Page 43 of 47
S-FSK Phy&MAC setup IC50-1 0-0:26.0.0.255 Access Rights T248
(Client 16/102/1)
1 logical_name octet-string[6] 00001A0000FF -/-/G
2 initiator_electrical_phase enum 0 -/-/G
3 delta_electrical_phase enum 1 -/-/G
4 max_receiving_gain unsigned -/S/GS
5 max_transmitting_gain unsigned -/S/GS
6 search_initiator_gain unsigned -/S/GS
7 frequencies frequencies_typ {63300,74000} -/S/GS
e
8 mac_address long-unsigned 0xFFE -/-/G
9 mac_group_addresses array[5] {0,0,0,0,0} -/-/GS
10 repeater enum 1 -/-/GS
11 repeater_status boolean -/-/G
12 min_delta_credit unsigned 0 -/S/GS
13 initiator_mac_address long-unsigned 0x0000 -/-/G
14 synchronization_locked boolean -/-/G
15 transmission_speed enum 3 -/S/GS
Page 44 of 47
(Client 16/102/1)
1 logical_name octet-string[6] 00001A0200FF -/-/G
2 search_initiator_timeout long-unsigned -/S/GS
3 synchronization_confirmation_ timeout long-unsigned -/S/GS
4 timeout_not_addressed long-unsigned -/S/GS
5 timeout_frame_not_OK long-unsigned -/S/GS
Profile status
Flag Description
Page 45 of 47
Bit 7 Power down: This bit is set to indicate that an all-phase power
PDN failure occurred.
Bit 6 not used
Bit 5 Clock adjusted: The bit is set when the clock has been adjusted
CAD more than the synchronisation limit. At the same time the DNV flag
is set because the capture period deviates from its nominal lengths
and may not be used for billing.
Bit 4 not used
Bit 3 Daylight saving: Indicates whether or not the daylight saving time
DST is currently active. The bit is set if the daylight saving time is active
Bit 2 (summer) and cleared
Data not valid: in that
Indicates winter.
the current entry may not be used for
DNV billing e.g. due to time shift or if no values have been recorded
during the capture period.
Bit 1 Clock invalid: The power reserve of the calendar clock has been
CIV exhausted. The time is declared as invalid. At the same time the
Bit 0 Critical error: A serious error such as a hardware failure or a
ERR checksum error has occurred. At the same time, the DNV bit is set.
Alarm descriptor
Alarm Descriptor
Bit Alarm
0 PLC state new
1 Clock invalid
2 reserved
3 reserved
Page 46 of 47
4 reserved
5 reserved
6 reserved
7 Extended Alarm status
Alarm Descriptor is related to CIASE Alarm Delivery where bit 0 is PLC_NEW, 1 to 6 are the same as in the Alarm Register bits 0 to 5 and bit 7
indicates Extended Alarm status that any of bit 6 to bit 31 of Alarm Register is set.
Page 47 of 47