0% found this document useful (0 votes)
21 views

Dna Uv

This document provides instructions for using a spectrophotometer to determine the concentration and purity of DNA or RNA samples. The instructions specify taking absorbance readings of diluted samples at 260nm and 280nm, which allows calculating the concentration from the 260nm reading and assessing purity from the 260/280 ratio. Diluting the sample 1:100 in buffer is recommended before placing it in a cuvette to take readings on the spectrophotometer.

Uploaded by

lovehope
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
21 views

Dna Uv

This document provides instructions for using a spectrophotometer to determine the concentration and purity of DNA or RNA samples. The instructions specify taking absorbance readings of diluted samples at 260nm and 280nm, which allows calculating the concentration from the 260nm reading and assessing purity from the 260/280 ratio. Diluting the sample 1:100 in buffer is recommended before placing it in a cuvette to take readings on the spectrophotometer.

Uploaded by

lovehope
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

Spectrophotometric Determination of DNA or RNA Concentration Kay Finn last updated: 4/30/03 Summary Read AU of sample at 260 nm and

280 nm in Baker lab. Try 1/100 dilution in cuvette: Place 495 ul of buffer and blank the cuvette; then add 5ul of sample with long tip and mix well (but gently without making bubbles!) pipetting up and down. Read absorbance at the two wavelengths using the multiple wavelength setting.

Detailed Instructions Ask before using the Baker lab Agilent Spectrophotometer. Sign in the log, select F1 (tasks) (enter) as multi wavelength, using up and down arrows. Type in 260 and 280. Then done. Make sure lamps are on with m button. Select lamps on/off (enter) turn on/off with arrows <= or =>. Wait at least 10 min for lamps to warm up. Place our cuvette (masked, semi-micro) in place with the 495 ul of buffer (for example, 1X TE) as blank. Lock in place. Press Blank Button. Check the blank, by pressing the Sample button to confirm that the reading is > 0.003. Loosen and remove cuvette, add the sample (5 ul) to the buffer, mix gently, replace cuvette and lock down and read at least 2x. Print out results. Absorbance reading at 260nm allows the calculation of Concentration of nucleic acid: An OD of 1 corresponds to approximately: * 50 ug/ml of DNA for double-stranded DNA * 40 ug/ml for single-stranded DNA and RNA * 20 ug/ml for oligonucleotides. Ratio of readings at 260nm and 280nm [A 260/ A 280] provides an estimate of Purity of the nucleic acid. Pure preparations of DNA and RNA have ratios of 1.8 2.0. If there is significant contamination with protein or phenol, the ratio will be lower and accurate quantitation is not possible. ds DNA OD=1 => 50 ug/ml extinction coefficient = 1/ 50 = 0.02