Flantness Report

This dimensional inspection report summarizes flatness measurements of the bottom of a waste disposal tank. Measurements were taken at 0, 45, 90, 135, 180, 225, 270, and 315 degrees around the bottom perimeter. All measurements were within the required tolerance of 35 mm or less. The inspector concluded that the bottom slope of 1:120 met specifications and all dimensions were acceptable for the tank to proceed to hydrotesting.

Uploaded by

aamirsaddiq
Copyright
© Attribution Non-Commercial (BY-NC)
Available Formats
Download as DOC, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
123 views

Flantness Report

This dimensional inspection report summarizes flatness measurements of the bottom of a waste disposal tank. Measurements were taken at 0, 45, 90, 135, 180, 225, 270, and 315 degrees around the bottom perimeter. All measurements were within the required tolerance of 35 mm or less. The inspector concluded that the bottom slope of 1:120 met specifications and all dimensions were acceptable for the tank to proceed to hydrotesting.

Uploaded by

aamirsaddiq
Copyright
© Attribution Non-Commercial (BY-NC)
Available Formats
Download as DOC, PDF, TXT or read online on Scribd
You are on page 1/ 1

DATE: 28-10-2007

Report # 4266-02-01
SHEET 01 OF 01

DIMENSIONAL INSPECTION REPORT


(BOTTOM FLATNESS)
CUSTOMER
EQUIP
NAME

SNC LAVALIN / SAUDI ARAMCO


BACKWASH DISPOSAL
TANK

WORK ORDER #

API 650

APPLICABLE CODE

B25-D0106

EQUIP TAG
#

4266-M0201REV. 3

DRAWING #

PROCEDURE #
0

FOR TANK SHELL DIA 10


METERS- TAKE BOTTOM
FLATNESS READING
@ 0-90-180-270
(0,1,2,3,4 & -1,-2,-3,-4)

4266

---4

315

45

3
2

FOR TANK SHELL DIA 25


METERS- TAKE BOTTOM
FLATNESS READING
@ 0-45-90-135-180-225-270-315
(0,1, 2,3,4,5 & -1,-2,-3,-4,-5)

1
270

90
-1

-2
-3
225

135
-4
180

H: REFERENCE HEIGTH
1 1
120

SL
#

DESCRIPTION

REQUIRE
D VALUE

1.

BOTTOM FLATNESS 0-180

35

2.

BOTTOM FLATNESS 45225

35

3.

BOTTOM FLATNESS 90270

35

4.

BOTTOM FLATNESS 135315

120

AS MEASURED
1
0
-1

-2

-3

-4

REMARKS

35

COMMENTS:

Requred value is as per API 650, refer to ASME Code Section II Part A(Page 48) SA-6/SA-6M
(table A1.13)
note: 150 mm measuring point from bottom to up on shell.
All reading are acceptable.
Dimensions are in mm unless otherwise specified.
Dimensions carried out before hydrotest.
As per Drawing Bottom Slope is 1:120= 25.4 from center of tank at both side.

DESIGNATION

QC INSPECTOR (ODICO)

QC ENGINEER

NAME

_____________________

_____________________

SIGN

_____________________

_____________________

DATE

_____________________

_____________________

CLIENT:
REPRESENTATIVE
_____________________
_____________________
_____________________

You might also like