PF Tranducer 2

MECO AC Power Factor Transducers measure the Power Factor in 1 Phase and 3 Phase electrical systems. The resulting output signal is directly proportional to the system Power Factor. The output can be connected to controllers, data-loggers, PLC's, Analog / Digital Indicators, Recorders for display, analysis or control.

Uploaded by

Sahil Bhouraskar
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
22 views

PF Tranducer 2

MECO AC Power Factor Transducers measure the Power Factor in 1 Phase and 3 Phase electrical systems. The resulting output signal is directly proportional to the system Power Factor. The output can be connected to controllers, data-loggers, PLC's, Analog / Digital Indicators, Recorders for display, analysis or control.

Uploaded by

Sahil Bhouraskar
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

Power Factor Transducer

(DIN Series)
Type 1Phase 3Phase 3Phase 3Phase 1Element 1Element 2Element 3Element 2Wire 2Wire 3Wire 4Wire - Zero Crossing (Balanced) - Zero Crossing (Balanced & Unbalanced) - TRMS (Balanced & Unbalanced) - TRMS DIN Series PFT11 PFT31 PFT33-TRMS PFT34-TRMS

(Back Panel Series)


Back Panel Series BPPFT11 BPPFT31 BPPFT33-TRMS -

MECO AC Power Factor Transducers measure the Power Factor in 1 Phase and 3 Phase electrical systems. The resulting output signal is directly proportional to the system power factor. These Transducers provide an output which is load independent and isolated from the input. The output can be connected to Controllers, Data-Loggers, PLC's, Analog / Digital Indicators, Recorders for display, analysis or control. They are ideal for SCADA, Energy Management, Telemetering for Remote, Local as well as Central Monitoring Systems. 63.5/110/230/440 V (any one only) Input Current 1/5 A (any one only) Input Frequency 50/60 Hz (any one) Input PF Range 0.5 (Lead)-1-0.5 (Lag) 0.8 (Lead)-1-0.2 (Lag) Measuring Range 0.8Un~1.2Un, 0.2In~1.2In Overload (continuous) 2 x In and 1.2 x Un Burden (Voltage) < Un x 5.5mA/Phase < 6 VA for Self Powered Burden (Current) < 0.5VA / Phase Optional l Above Input Ranges with suitable CTR/PTR also available l Bi-directional inputs for Import / Export of Power Dimension DIN Series : Note : Case Size III CE marked against order AC Input Input Voltage DC Output Current Output Load 0-1 mA 0-10 KV 0-5 mA 0-2 KV 0-10 mA 0-1 KV 2-10 mA 0-20 mA 0-500 V 4-20 mA Voltage Output Load 0-1 V > 1 kV 0-5 V > 5 kV 1-5 V 0-10 V >10 kV 2-10 V Auxiliary Power Supply Tolerance ( 20 %) AC 110 V 230 V DC 12 V 24 V 48 V 110 V 220 V Burden

< 4 VA

Optional l Dual Non-Isolated / Dual Isolated Outputs l Dual Symmetrical & Asymmetrical Outputs l Bi-directional Outputs

Optional Other Auxiliary Power Supplies available subject to technical feasibility

l l

Detailed specifications of BP Series on request

For Case Size refer General Specifications

Connection Diagram