CODES Consultants, Inc.: Design of Column (C2)
CODES Consultants, Inc.: Design of Column (C2)
Description :
I.] DESIGN SPECIFICATIONS : 1.1 National Structural Code of the Philippines (NSCP), Volume II - Bridges 2nd Edition, 1997
b = 500
1.2 American Association of State Highway and Officials (AASHTO), Sixteenth Edition, 1996
( Input Data ) II.] MATERIALS : 2.1 Concrete : Compressive Strength, Column Width, Depth, Cover to Main Bars, 2.2 Deformed Bars : Main Bars Diameter,
f'c b h c Db
= = = = =
20.700 500.000 500.000 62.500 28.000 8.000 12.000 4.000 276.000 0.850 68.190
MPa mm mm mm mm pc mm pc MPa kN
Number of Bars, Sec. Bars Yield Strength, Shear, Shear Force, Diameter, Number of Legs, 2.3 Red'n. Factors 2.4 Factored Forces : :
Nb = Ds = Ns fy Vu = = = =
III.] CALCULATIONS : 3.1 Permissible Shear on Concrete 1/2 Vc = (1/6)(b*d)(f'c) / 1000 NSCP (8-51) Vc = 156.018 kN 3.2 Shear to be Carried by the Secondary Bars Vs = Vn - Vc NSCP (8-47)
where :
where : kN Vs = -75.794 3.3 Required Spacing Sreq = (Av*fy*d) / (Vs*1000) NSCP (8-53) where : mm Sreq = -677.88 3.4 Spacing due to Minimum (A v) Smin = (3*Av*fy) / b NSCP (8-64) mm 749.157 = 3.5 Maximum Spacing (NSCP Articles 8.19.3, 8.16.6.3.8 &8.18.2.3) Smax = Min. [ d/4 or 600mm ] for V s < 2(Vc) 100.000 mm = Use : 12mm - 4 ( Legged ) Ties @ 740mm O.C
kN
mm
500
h = 500