PV System Load Estimation Worksheet

The document is a worksheet for estimating the load and sizing the components of a photovoltaic (PV) system. It lists individual household loads such as lights, appliances, electronics and their power requirements in watts. It then calculates the total connected watts, average daily load in watt-hours, and estimated battery and inverter requirements to power the system based on the load analysis. Component sizing worksheets are also included to determine the necessary PV panel array, controller, inverter and battery bank specifications to meet the load needs of the system.

Uploaded by

Ryan Burns
Copyright
© Attribution Non-Commercial (BY-NC)
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
100% found this document useful (1 vote)
457 views

PV System Load Estimation Worksheet

The document is a worksheet for estimating the load and sizing the components of a photovoltaic (PV) system. It lists individual household loads such as lights, appliances, electronics and their power requirements in watts. It then calculates the total connected watts, average daily load in watt-hours, and estimated battery and inverter requirements to power the system based on the load analysis. Component sizing worksheets are also included to determine the necessary PV panel array, controller, inverter and battery bank specifications to meet the load needs of the system.

Uploaded by

Ryan Burns
Copyright
© Attribution Non-Commercial (BY-NC)
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
You are on page 1/ 13

PV System Load Estimation Worksheet

Zone Individual Loads Qty 1 Kids Lights 4 1 Parents Lights 4 1 Living Room Light 2 1 Kitchen Lights 5 1 Living Room TV 1 1 Lights Other 1 1 Sarah TV 1 1 Microwave 1 1 Cable Box 1 1 DVD Player 1 1 Refrigerator 1 1 Coffee Maker 1 3 AC/Heat 1 3 Water Heater 1 1 Laptop 1 1 Main Computer 1 1 Monitor 1 1 External HD 1 1 Cable Modem 1 1 Router 1 2 Clothes Washer 1 4 Clothes Dryer 1 1 Phone System 1 2 Deep Freezer 1 2 Dish Washer 1 X X X X X X X X X X X X X X X X X X X X X X X X X X X X X Amps = X 0.11 = X 0.11 = X 0.11 = X 0.5 = X 1.84 = X 0.5 = X 1 = X 8 = X 0.29 = X 0.2 = X 7 = X 7.5 = X 23 = X 24 = X 2.2 = X 6 = X 1.5 = X 0.55 = X 0.15 = X 0.1 = X 12 = X 24 = X 1 = X 1.69 = X 2.2 X X = AC Total Connected Watts: AC DC Volts Volts 120 120 120 120 120 115 120 120 120 120 115 120 208 220 120 120 120 120 120 120 120 240 120 115 120 Watts AC 52.32 52.32 26.16 300.00 220.80 57.50 120.00 960.00 35.10 24.00 805.00 900.00 4784.00 5280.00 264.00 720.00 180.00 66.00 18.00 12.00 1440.00 5760.00 120.00 194.35 264.00 0.00 0.00 22655.55 Watts DC 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Use X Hrs /Day X 3 X 1 X 1 X 0.5 X 13 X 22.5 X 5 X 0.1 X 24 X 0.25 X 5 X 4 X 5 X 5 X 4 X 6 X 6 X 6 X 24 X 24 X 2.25 X 3 X 6 X 5 X 1 X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X Use Days /Wk 7 7 7 7 7 7 7 7 7 7 7 6 7 7 7 7 7 7 7 7 7 7 7 7 6 Watt Hours 7 Days = AC 7 = 156.96 7 = 52.32 7 = 26.16 7 = 150.00 7 = 2870.40 7 = 1293.75 7 = 600.00 7 = 96.00 7 = 842.40 7 = 6.00 7 = 4025.00 7 = 3085.71 7 = 23920.00 7 = 26400.00 7 = 1056.00 7 = 4320.00 7 = 1080.00 7 = 396.00 7 = 432.00 7 = 288.00 7 = 3240.00 7 = 17280.00 7 = 720.00 7 = 971.75 7 = 226.29 7 = 0.00 7 = 0.00 AC Average Daily Load: 93534.74 AC kWh / Month: 2806.04 DC Average Daily Load: DC kWh / Month:

DC Total Connected Watts:

PV System Battery Sizing Worksheet


AC Average Daily Load (wt-hr/day)

Inverter Efficienc ey

DC Average Daily Load (wthr/day)

DC System Voltage

Average Amp hours/day

93534.74
Average Amphours /day

0.90
Days of Autonom y

+ = =

0.00
% Discharge Limit on Battery

48
Battery AH Capacity

= = = = =

2165.16
Batteries in Parallel

2165.16
DC Voltage System

4
Battery Voltage

0.50

350
Batteries in Parallel

49
Total Batteries

Batteries in Series

48

24

49

98.98

PV Panel Array Sizing Worksheet


Average AmpHrs / day

Battery Efficienc ey

= = =
Make:

Peak Sun Hrs/day

= =

Array Peak Amps

2165.16

0.80
Peak Amps / Module

4.10
Modules in Parallel

660.11
Module Short Circuit Current

Array Peak Amps

660.11

5.02
Nominal Module Voltage

131.5

5.34

DC Voltage System

Modules in Series

Modules in Parallel

= =

Total Modules

48.00

12

4.00

5
Model:

20.00

Panel Specification

PV Controller Sizing Worksheet


Module Short Circuit Current

Modules in Parallel

=
Make:

1.25

= =

Array Short Circuit Amps

Controller Array Amps

Listed Desired Features


Temp Compensation, digtal Volt Meter

5.34

131.5
DC System Voltage

1.25

33.38

40.0

DC Total Connected Watts

Maximum DC Load Amps

Controller Load Amps

0.00
Controller Specification

48

0.0
Model:

PV Inverter Sizing Worksheet


AC Total Connected Watts DC System Voltage Estimated Surge Watts (In Rush =Min of 36 times Total Connected Watts )

22655.55
Inverter Specification

48
Make:

67966.65
Model:

Watt Hours DC Zone 0.00 1 0.00 2 0.00 3 0.00 4 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00

0.00 0

Watt
30000

25000

239

20000

15000

10000

5000 2870 1294 0


Li

4025 3086 600


TV

157
ts gh

52

26
t gh

150
TV

96

842

6
to r

ox

ra

Li

ra

le

oo

ge

Sa

ab

Ki d

oo

vi n

Li

Li

vi n

ef

ri

/H

ea

ef ri ge ra to r

4025 3086

A C /H ea

23920

26400

La pt op

Watt Hours AC

1056 4320

M on ito

1080

C ab

396

le M od em

432

C lo th e

288

s W as he

3240

Ph o ne Sy st em

17280

720

972

is h

as he

22

17280

Watt Hours AC

720

972

226
as he r

Sy st em

ne

Ph o