0% found this document useful (0 votes)
184 views

Hysys Pipe

This document discusses simulating the steady state conditions of natural gas pipelines in Iran using Hysys software. It finds that the pressure and flow rate results from the steady state simulation match closely with actual average field data from the gas company, showing the accuracy of the simulation. The simulation can be used for predicting pipeline conditions and optimizing the gas transmission network.

Uploaded by

sang3011
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
184 views

Hysys Pipe

This document discusses simulating the steady state conditions of natural gas pipelines in Iran using Hysys software. It finds that the pressure and flow rate results from the steady state simulation match closely with actual average field data from the gas company, showing the accuracy of the simulation. The simulation can be used for predicting pipeline conditions and optimizing the gas transmission network.

Uploaded by

sang3011
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 9

Hysys

- -
- -

.

.
.


.

Hysys .
) (
.
.
: Hysys Pipesegment

-1

.

.



.
.
)
(.
:
Email:[email protected]


( :
.
.
.
) ( .
.
( ) ( :

.
.
.

-
.
) ( PengRobinson
1].[2
Pipesegment
Hysys .
) ( (Finite
) difference .
Moody 2 ].[3
.
.

.
-2
.
.
4 ]: 5.[6

+ + +
=

dv2 g
+ dz+ d( pv)+ dQ- dWs= 0
2gc gc
)(1
.

dv2
g
dp +r
+
. ) ( WS rdz+ rdlw = 0
2gc gc
) (:
du +

)(2

Dv2 g
Dp + r
+
rDz+ Dpf = 0
2gc gc

) (2 :
)(3

f Lr v2
= Dpf
2gcd

Dp f
.
Dp f :
)(4

f L v d .
) (4 ) (3
:
0.01875
ggz
Tav

(z/p)dp

2 5

()

2 2 2
sc

fLq z T zp d
)(5

1+ (6.739310

-4

Hysys
) ( z
.[3]
-3



.
.
.
1068 .
36 ) ( 16 .
36 139 .
139 30 .
40 714
30 .
.
-4 Hysys
:
:1

98/51015

0/668933

0/078992

0/019998

0/072993

0/025997

0/019998

0/094991

0/479952

0/027997

:2

(bar)

68

(oC)

42

(MMSCMD)

40

/7
52

42
25


157 .
Hysys Pipe segment .
) (Valve ) (TEE .
.
) (segments
.
)( ) 1068 (
.

. 1 2
.

MashhadYard(0km_138km)

MashhadYard(139km_300km)
1400

1000
800
600
400

E lev ationfrom s ealine(m )

1200

200
0
140

120

100

80

60

40

20

300

280

260

240

220

200

PipeLength(Km)

PipeLength(Km)

180

160

800
600
400
200
0
140

E levationfrom sealevel
) (m

1600
1400
1200
1000

: 1 139
139 300

:2

Pipesegment
. .
Asphalt 4/5 .
.
.
) ( .

. 3 4
.

: 3

: 4

25
5 .

:5 Hysys

-5

. ) (6 ) (7

) ( .

PressureProfile

FlowDiagram
70

25

65

50
45

15

10

40

5
35

1200

1000

800

600

200

1200

1000

800

600

400

200

400

PipeLineLength(Km)

PipeLineLength(Km)

30

) Flow(MMS C MD

55

Pressure(bar)

60

20


:7

:6


1385 3 .
1 /5
7 .
)
(.

: 3 ) (1385

)(

47

47/27

0/57

)(

68/12

68

0/18

)(

50/64

51/16

1/37

)(

68

68

0/00

)(

51/6

51/74

0/27

)(

59/7

60

0/50

)(

46/48

44/6

4/04

)(

57/2

56/74

0/80

)(

44/4

41/55

6/42

)(

48/13

48/19

0/12

-6
-1
3 1385
.
-2
.
-3
1 /5



.
-4
.
.
.

" "
.


.

[1]

.1376

[2]Hysys3.1Documentations,SimulationBasis,HyprotechCo.,2002.
[3]Hysys3.1Documentations,OperationsGuide,HyprotechCo.,2002
[4]SanjayKumar,GasProductionEngineering,GulfPublishingCompany,1987.
[5]GPSAElectronicDataBook,Bythe Gas ProcessorsSuppliers Association, 11thEdition,
1998.
[6]J.P.BrillandH.D.Beggs,TwoPhaseFlowinPipes,6thEdition,1989.

You might also like