Simatic NCM Manager
Simatic NCM Manager
Release 01
Information on
Advanced PC Configuration
and
SIMATIC NCM PC
Content
History of the document Supported and not supported boards and software Advanced PC Configuration Change to the SIMATIC NET PC-Software CD 07/2001 (Chapter 4: Part of the installation manual SIMATIC NET PC-Software CD 07/2001) Configuring PC Stations with SIMATIC NCM PC - Manual and Quick Start Part of the catalogue IK PI 2001 for PC boards and software Part of the catalogue IK PI 2000 for PC boards and software
Release 01
Release 01
CP 5511 CP 5611
(and integr. PB interfaces in the IPCs/PGs -> Prerequisite: CP 5611 compatible)
IK PI 2001 IK PI 2001
More details can be found in description SIMATIC NET PC-Software CD 07/2001 chapter 4.3 and chapter 4.4.
Release 01
CP 5511 CP 5611
(and integr. PB interfaces of the IPCs/PGs -> Prerequisite: CP 5611 compatible)
IK PI 2000 IK PI 2000
CP 5412 (A2)
IK 10 1999
CP 5411 MPI-ISA
(and integr. Interfaces of IPCs/PGs, which are not compatible to CP 5611)
IK 10 1999
TF-1613/Windows all releases S7-1613/Windows up to V2.1 PG-1613/Windows up to V2.1 TF-1413/Windows all releases S7-1413/Windows all releases PG-1413/Windows all releases SOFTNET-S7/Windows up to V3.3 SOFTNET-PG/Windows up to V3.3 SOFTNET-S7/Windows up to V3.3 SOFTNET-PG/Windows up to V3.3
More details can be found in description SIMATIC NET PC-Software CD 07/2001 chapter 4.3 and chapter 4.4.
4.1
Features
Using Advanced PC Configuration means certain changes in the way you configure in your project: All settings are made and downloaded to the PC station with one tool during configuration. This tool is the SIMATIC NCM PC V5.1 Service Pack 2 or STEP 7 version 5.1 Service Pack 2 program or higher. Properties that were previously configured using the Set PG/PC Interface program are now part of the configuration and are downloaded to the PC station. These include, for example, the station address and the bus parameters. Creating several databases is no longer necessary. Properties that were previously specified in various configuration programs are now configured in SIMATIC NCM PC V5.1 Service Pack 2 or STEP 7 Version 5.1 Service Pack 2 or higher. Examples of such configuration tools include COML S7, COM PROFIBUS. Configuration parameters for the OPC Server that were previously stored in TXT files are now configured in SIMATIC NCM PC V5.1 Service Pack 2 or STEP 7 Version 5.1 Service Pack 2 and downloaded to the PC station.
86
Supported Modules
You will find a list of modules supported and not supported by Advanced PC Configuration in the hinw_e.rtf file on the SIMATIC NET product CD (<CD drive> sw cdintern hinw_e.rtf).
Consequences
The following sections explain the effects of switching to Advanced PC Configuration. You should also read the chapter Installation and Commissioning in the HTML document Industrial Communication for PG/PC supplied on the CD.
87
4.2
4.2.1
88
4.2.2
Description
A configuration created with the tools of the SIMATIC NET product CDs up to and including SIMATIC NET CD 05/2000 will be called the previous configuration in the description below.
89
90
4.2.3
Description
Configuration with Advanced PC Configuration means configuring with the tools of the SIMATIC NET CD Version 07/2001 or higher.
91
4.2.4
Protocol DP
Continued Use Continued use not possible, the configuration must be recreated with SIMATIC NCM PC V5.1 Service Pack 2 or STEP 7 Version 5.1 Service Pack 2 or higher. Continued use not possible, the configuration must be recreated with SIMATIC NCM PC V5.1 Service Pack 2 or STEP 7 Version 5.1 Service Pack 2 or higher. Continued use not possible, the configuration must be recreated with SIMATIC NCM PC V5.1 Service Pack 2 or STEP 7 Version 5.1 Service Pack 2 or higher. Continued use not possible, the configuration must be recreated with SIMATIC NCM PC V5.1 Service Pack 2 or STEP 7 Version 5.1 Service Pack 2 or higher. Continued use possible, the XDB database must be imported. Continued use not possible, the configuration must be recreated with SIMATIC NCM PC V5.1 Service Pack 2 or STEP 7 Version 5.1 Service Pack 2 or higher. Continued use possible, as previously with COML TF.
FDL
TXT
Text Editor
FMS
LDB
COM PROFIBUS
S7
LDB
COML S7
S7 SEND/ RECEIVE
XDB TXT
TF
LDB
COML TF
Note If you want to continue using the previous configuration tools, use the SIMATIC NET CD 05/2000.
92
4.3
Industrial Ethernet - Effects on Older Product Versions (SIMATIC NET CD 05/2000 and earlier)
Introduction
This section describes what changes are necessary in Industrial Ethernet systems if you are already using a SIMATIC NET CD 05/2000 product or a previous version.
PG-1413, S7-1413, TF-1413 up to version 5.2 with Service Pack 2 for Windows NT 4.0 or Windows 98
Situation: These products are not supported by the SIMATIC NET CD 07/2001. Simultaneous installation of these products with products of the new CD 07/2001 is not permitted and is prevented. Steps to take: Keep using the products of the SIMATIC NET 5/2000 CD if you want to use a CP 1413 in your computer or replace it with a CP 1613.
93
SOFTNET-PG up to version 3.3 for Windows 2000 Pro, Windows NT 4.0 or Windows 98
Situation: Windows 98 is no longer supported. PG operation under Windows 2000 Pro or Windows NT 4.0 remains possible and is unchanged. Steps to take: Under Windows 98, use the SIMATIC NET CD 05/2000.
SOFTNET-PG up to version 3.3 with Service Pack 2 for Windows 2000 Pro, Windows NT 4.0, Windows Me or Windows 98
Situation: Windows Me and Windows 98 are no longer supported. PG operation under Windows 2000 Pro or Windows NT 4.0 remains possible and is unchanged. Steps to take: Under Windows Me or Windows 98, use the SIMATIC NET CD 05/2000.
94
SOFTNET-S7 up to version 3.3 for Windows 2000 Pro, Windows NT 4.0 or Windows 98
Situation: Windows 98 is no longer supported. An S7 configuration created with the COML S7 program cannot be used. Steps to take: Under Windows 98, use the SIMATIC NET CD 05/2000. A configuration created with the COML S7 program must be recreated with SIMATIC NCM PC V5.1 Service Pack 2 or STEP 7 Version 5.1 Service Pack 2 or higher. If the configuration was already created with STEP 7 (XDB), this STEP 7 project can continue to be used. You only need to download the configuration to the CP/PC station from STEP 7 Version 5.1 Service Pack 2 or higher.
95
4.4
PROFIBUS - Effects on Older Product Versions (SIMATIC NET-CD 05/2000 and earlier)
Introduction
This section describes what changes are necessary in PROFIBUS systems if you are already using a SIMATIC NET CD 05/2000 product (or a previous version).
DP-5412, FMS-5412, PG-5412, S7-5412 up to version 5.2 with Service Pack 2 for Windows NT 4.0 or Windows 98
Situation: These products are not supported by the SIMATIC NET CD 07/2001. Simultaneous installation of these products with products of the new CD 07/2001 is not permitted and is prevented. Steps to take: Keep using the products of the SIMATIC NET 05/2000 CD if you want to use a CP 5412 in your computer or replace it with a CP 5613.
96
SOFTNET-DP up to version 5.3 for Windows 2000 Pro, Windows NT 4.0 or Windows 98
Situation: Windows 98 is no longer supported. A DP configuration created with the COM PROFIBUS program cannot be used. It will be possible to configure Send/Receive communication on the basis of the FDL interface over OPC with SIMATIC NCM PC or STEP 7 in the future! Steps to take: Under Windows 98, use the SIMATIC NET CD 05/2000. A DP configuration created with the COM PROFIBUS program must be recreated with SIMATIC NCM PC V5.1 Service Pack 2 or STEP 7 Version 5.1 Service Pack 2 or higher. If the configuration was already created with STEP 7, this STEP 7 project can continue to be used. You only need to download the configuration to the CP/PC station from STEP 7 Version 5.1 Service Pack 2 or higher.
97
SOFTNET-DP slave up to version 1.2 for Windows 2000 Pro, Windows NT 4.0 or Windows 98
Situation: Windows 98 is no longer supported. Steps to take: Under Windows 98, use the SIMATIC NET CD 05/2000.
SOFTNET-S7 up to version 5.3 for Windows 2000 Pro, Windows NT 4.0 or Windows 98
Situation: Windows 98 is no longer supported. An S7 configuration created with the COML S7 program cannot be used. Steps to take: Under Windows 98, use the SIMATIC NET CD 05/2000. A configuration created with the COML S7 program must be recreated with SIMATIC NCM PC V5.1 Service Pack 2 or STEP 7 Version 5.1 Service Pack 2 or higher. If the configuration was already created with STEP 7 (XDB), this STEP 7 project can continue to be used. You only need to download the configuration to the CP/PC station from STEP 7 Version 5.1 Service Pack 2 or higher.
98
Preface, Contents
Manual Introduction and Notes on Switching to Advanced PC Configuration Configuring SIMATIC PC Stations Configuring the OPC Server
1 2 3
Quick Start Configuring the OPC Server Quick Start with PROFIBUS-DP Configuring the OPC Server Quick Start with Industrial Ethernet
4 5
A B
Danger indicates that death, severe personal injury or substantial property damage will result if proper precautions are not taken.
Warning indicates that death, severe personal injury or substantial property damage can result if proper precautions are not taken.
Caution indicates that minor personal injury or property damage can result if proper precautions are not taken.
Vorsicht indicates that property damage can result if proper precautions are not taken.
Notice highlights important information on the product, using the product, or part of the documentation that is of particular importance and that can have detrimental results if ignored.
Note highlights important information on the product, using the product, or part of the documentation that is of particular importance and that will be of benefit to the user.
Trademarks
SIMATICR, SIMATIC HMIR and SIMATIC NETR are registered trademarks of SIEMENS AG. Third parties using for their own purposes any other names in this document which refer to trademarks might infringe upon the rights of the trademark owners.
Qualified Personnel
Only qualified personnel should be allowed to install and work on this equipment. Qualified persons are defined as persons who are authorized to commission, to ground, and to tag circuits, equipment, and systems in accordance with established safety practices and standards.
Warning This device and its components may only be used for the applications described in the catalog or the technical description, and only in connection with devices or components from other manufacturers which have been approved or recommended by Siemens. This product can only function correctly and safely if it is transported, stored, set up, and installed correctly, and operated and maintained as recommended. Before you use the supplied sample programs or programs you have written yourself, make certain that no injury to persons nor damage to equipment can result in your plant or process. EU Directive: Do not start up until you have established that the machine on which you intend to run this component complies with the directive 89/392/EEC.
Warning This software may only be used for the applications described in the catalog or the technical description, and only in connection with software products, devices, or components from other manufacturers which have been approved or recommended by Siemens. Before you use the supplied sample programs or programs you have written yourself, make certain that no injury to persons nor damage to equipment can result in your plant or process.
Copyright E Siemens AG 1999/2000 All rights reserved The reproduction, transmission or use of this document or its contents is not permitted without express written authority. Offenders will be liable for damages. All rights, including rights created by patent grant or registration of a utility model or design, are reserved.
Disclaimer of Liability We have checked the contents of this manual for agreement with the hardware and software described. Since deviations cannot be precluded entirely, we cannot guarantee full agreement. However, the data in this manual are reviewed regularly and any necessary corrections included in subsequent editions. Suggestions for improvement are welcomed.
Siemens AG Bereich Automatisierungstechnik Geschftsgebiet Industrie-Automatisierung Postfach 4848, D-90327 Nrnberg Siemens Aktiengesellschaft
This manual...
... supports you and helps you to make efficient use of the communications functions of your PC applications in conjunction with the SIMATIC NET modules. ... supplements the OPC documentation on the SIMATIC NET PC / Windows CD. The descriptions are structured as shown below:
PC CD / OPC Documentation
S General
information on PC tools
S Functions of NCM
PC
S Detailed OPC
description
S Configuring the
OPC Server
Quick Starts
S OPC application
with communication over Ethernet.
S OPC application
with access to a DP master system
S PROFInet
applications
This manual...
Additional Information
This manual is also part of the documentation packages for NCM S7 for PROFIBUS and Industrial Ethernet. Tip: This symbol appears in the margin to draw your attention to useful tips.
S S S S
User Manual Programming Manual Manual for converting from S5 to S7 Primer for a fast start
Conventions
References to other manuals and documentation are indicated by numbers in slashes /.../. These numbers refer to the titles of manuals listed in the References section of the Appendix. -
Contents
1 2 Introduction and Notes on Switching to Advanced PC Configuration . . . . . . . Configuring SIMATIC PC Stations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.1 2.2 2.3 2.3.1 2.3.2 2.3.3 2.3.4 2.3.5 2.4 2.5 2.6 2.7 2.7.1 2.7.2 3 Tools and Utilities . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Using tools Station Configuration Options . . . . . . . . . . . . . . . . . . . . . . . . . Configuring with SIMATIC NCM PC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Relationship Between SIMATIC NCM PC and STEP 7 . . . . . . . . . . . . . . . Creating a PC Station . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Configuring a PC Station with HW Config . . . . . . . . . . . . . . . . . . . . . . . . . . . Creating a DP Master System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Configuring Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Downloading the Configuration Data to the PC Station . . . . . . . . . . . . . . . Commissioning Wizard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PC Station Wizard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Station Configuration Editor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Managing Components: Components Tab . . . . . . . . . . . . . . . . . . . . . . . . . Diagnostics Tab . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 11 11 14 17 18 19 21 24 26 28 31 32 34 35 37 39 40 41 43 47 47 48 49 50 51 52 53 54 55 56 57 57 58 60 61 61 62 62 63
Configuring the OPC Server . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.1 3.2 3.3 Significance of Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Configuring the Properties of the OPC Server . . . . . . . . . . . . . . . . . . . . . . . Configuring Connection Properties for the OPC Server . . . . . . . . . . . . . . .
Quick Start for the OPC Application for PROFIBUS-DP . . . . . . . . . . . . . . . . . . . . 4.1 4.2 4.2.1 4.2.2 4.2.3 4.2.4 4.2.5 4.2.6 4.2.7 4.2.8 4.2.9 4.2.10 4.2.11 4.2.12 Example of a PROFIBUS Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . Quick Start for PROFIBUS Communication with OPC . . . . . . . . . . . . . . . . Hardware and Software Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Configuring the PC Station . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . STEP 7 Starting the PC Station Wizard . . . . . . . . . . . . . . . . . . . . . . . . . . . STEP 7 PC Station Wizard: Selecting the Editing Mode . . . . . . . . . . . . . STEP 7 PC Station Wizard: Changing Settings . . . . . . . . . . . . . . . . . . . . HW Config: Inserting a DP Master System . . . . . . . . . . . . . . . . . . . . . . . . . . HW Config: Inserting a DP Slave . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . HW Config: Downloading the Configuration . . . . . . . . . . . . . . . . . . . . . . . . . STEP 7 Commissioning Wizard: Specifying the Use of Symbol Files . . OPC Scout: Establishing a Connection to the OPC Server . . . . . . . . . . . . OPC Scout: Inserting a Group and Variables . . . . . . . . . . . . . . . . . . . . . . . . OPC Scout: Displaying and Modifying Values of Variables . . . . . . . . . . . .
Quick Start for the OPC Application for Industrial Ethernet . . . . . . . . . . . . . . . . 5.1 5.2 5.2.1 5.2.2 Example of an Industrial Ethernet Configuration . . . . . . . . . . . . . . . . . . . . . Quick Start for Industrial Ethernet Communication with OPC . . . . . . . . . . Hardware and Software Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Configuring the PC Station . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Contents
5.2.3 5.2.4 5.2.5 5.2.6 5.2.7 5.2.8 5.2.9 5.2.10 5.2.11 5.2.12 5.2.13 5.2.14 A
STEP 7 Starting the PC Station Wizard . . . . . . . . . . . . . . . . . . . . . . . . . . . STEP 7 PC Station Wizard: Selecting the Editing Mode . . . . . . . . . . . . . STEP 7 PC Station Wizard: Opening the Project . . . . . . . . . . . . . . . . . . . STEP 7 PC Station Wizard: Changing Settings . . . . . . . . . . . . . . . . . . . . STEP 7 NetPro . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . STEP 7 NetPro: Downloading the Configuration . . . . . . . . . . . . . . . . . . . . . STEP 7 Commissioning Wizard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Symbol File Configurator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SIMATIC NET Commissioning Wizard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . OPC Scout: Establishing a Connection to the OPC Server . . . . . . . . . . . . OPC Scout: Inserting a Group and Variables . . . . . . . . . . . . . . . . . . . . . . . . OPC Scout: Displaying and Modifying Values of Variables . . . . . . . . . . . .
65 66 67 68 69 70 70 71 72 73 74 76 77 77 79
SIMATIC NET Support and Training . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Customer Support, Technical Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Glossary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Note For more detailed information on the difference between the previous methods and working with the software and modules, refer to the CD documentation and the Installation Instructions of the SIMATIC NET PC software products.
10
2.1
Note You can configure both in SIMATIC NCM PC and in STEP 7. STEP 7 also provides all the SIMATIC NCM PC functions described here for configuring your PC. From now on, the description will only refer to SIMATIC NCM PC but nevertheless applies to both.
11
PC station
12
Further Utilities
From the graphic, you can see that there are other utilities available, for example for using the OPC Server interface. These utilities will be pointed out or described in greater detail where applicable. S Configuration Console A utility with which you can display the structure of a PC station in much the same way as in the Windows Explorer. The interactive options are Module diagnostics Setting the operating mode Configuration for specific situations S OPC Scout A utility that allows easy access to process data over the OPC interface. The interactive options are Displays of the configured communications channels representing the available OPC variables Monitoring, reading, and writing of process data
13
2.2
The following descriptions illustrate when and where to use the tools and utilities in various situations.
PG
Table 2-1 Tool / Utility ...use on Configuration Station SIMATIC NCM PC / STEP 7 is installed Station Configuration Editor yes no no optional Networked PC Station
S to edit a stored
configuration
S to create a new
configuration
14
Table 2-2 Tool / Utility ...use on Configuration Station = PC Station SIMATIC NCM PC / STEP 7 is installed Station Configuration Editor yes optional
S S S S
change local settings edit a stored configuration create a new configuration import XDB files
15
Table 2-3 Tool / Utility ...use on Configuration Station SIMATIC NCM PC / STEP 7 is installed Station Configuration Editor yes no no yes Networked PC Station
S to edit a stored
configuration
S to create a new
configuration
16
2.3
17
2.3.1
Notice Optional packages are not supported by SIMATIC NCM PC. If you are editing a project that was created or edited in STEP 7, it may contain components from STEP 7 optional packages. If this is the case, you can only edit stations using SIMATIC NET PC that do not contain components from STEP 7 optional packages. S open and edit projects you created with STEP 7/SIMATIC Manager at any time in SIMATIC NCM. You can edit PC stations you have already created and create new PC stations. You can configure communication connections from these PC stations to existing S7 stations.
The restrictions in SIMATIC NCM PC relate to the S7 station types that can be configured and programming. You can see the differences in the following graphic: SIMATIC NCM PC STEP 7
S S S S
S S S S
The types of stations that you can configure only in STEP 7 can be used in SIMATIC NCM PC as target stations for a connection configuration after importing the project. After working on such a project in SIMATIC NCM PC, you can return it to STEP 7 and edit it again at any time.
18
2.3.2
Creating a PC Station
Aims
You want to create configuration data for communication services for individual PC stations. This configuration data will then be downloaded to the PC station. After this, the PC applications can use the communications services. Tip: Remember that you can create a great deal of the project structure automatically using the PC Station Wizard! Read the information on starting and working with the wizard in Section 2.6. You will find examples in the Quick Start in Chapters 4 and 5.
For each PC station, you create a separate object of the type PC station.
These objects in turn contain the configuration and parameter data of the hardware and software. These objects are then used to assign the communications services. The objects are created with HW Config as shown in Section 2.3.3.
19
Notice The name selected here for the PC station identifies the PC configuration. If you define a configuration for the local PC with NCM PC, the name you select must be identical to the name of the actual local configuration. If you define a configuration for a remote PC station, the name must not be identical to that of the actual local configuration! Otherwise, the local configuration would be overwritten when you download.
Note When you start STEP 7, a wizard is opened that helps you to create a new project. In SIMATIC NCM PC, this wizard is replaced by the PC Station Wizard. Depending on your initial situation, this wizard provides you with more extensive support for your PC station. The PC Station Wizard also exists in STEP 7.
20
2.3.3
21
22
OPC Server You use the convenient interface to an OPC server to communicate with a programmable controller such as a SIMATIC S7-400. The OPC server can be set up as an interface for all available communications protocols. You can only create this object once in a PC station. You can then use this OPC Server for communication with any number of user programs (OPC clients). The following communications services can be used depending on the modules inserted: all types of connection DP services S S CP Industrial Ethernet This contains all the CP modules for attachment to Industrial Ethernet. CP PROFIBUS This contains all the CP modules for attachment to PROFIBUS.
23
2.3.4
You can then see the DP master system you have created.
24
Now insert the DP slaves you want to be addressed by the application from the catalog.
25
2.3.5
Configuring Connections
Meaning
During operation, configured connections are established either implicitly or on request, depending on the parameter assignment. They are then available to the OPC Server or the PC application for communication.
General Rules
Regardless of the type of application, these general rules apply when configuring connections: S S S Communication connections are always assigned to an application. In the PC station, the CP that supports the type of connection is used for the data transfer. If there is more than one CP with this capability, you can use Routing to select the transmission path.
26
2. Enter the desired connection type. When selecting the destination station, note the following: After creating a new project in SIMATIC NCM PC, you will normally find that the required destination station (for example an S7 station) does not exist. You then have the following options: Create an unspecified connection Select unspecified as the connection partner. In the Properties dialog box, you can then set the address parameters for the connection partner. Create a proxy object Create an Other Station. You then network this station by assigning the necessary interface types in the Properties dialog. This method is advisable if you intend to assign several connections to this partner station on the same interface in your project. Create a copy of an S7 station Insert the copy of an S7 station that you have created using STEP 7 in another project. You can then select this S7 station as your destination station.
27
2.4
Online Mode
The online mode allows you to download the configuration data directly to a PC station attached to the network (MPI, PROFIBUS or Ethernet) or to load the data on the local PC station if you are using this as the configuration station. S Online Networked (Configuration Station and PC Station Networked)
Download
Follow the steps below: 1. Switch the PG/PC station online. 2. Select the station you want to download to. 3. Download the configuration data with PLC > Download Make sure you set the correct interface in Set PG/PC Interface.
28
Load
Follow the steps below: 1. Select the station you want to load. 2. Load the configuration data using PLC > Download. Requirement: In the Set PG/PC Interface, you must first select the following setting as access point of the application: S7ONLINE (STEP7) > PC internal (local) Tip: If you use the PC Station Wizard, this setting is made automatically.
29
XDB import
Follow the steps below to create and import an XDB file: 1. Select the station on which you want to load the data in the STEP 7 project. 2. Open the object properties of the station with the Station Properties menu command and select the Configuration tab. 3. Here, you can check and, if necessary, change the setting under Storage Location of the Configuration File. 4. Save and compile your project; you will then find the required XDB file in the folder you have selected. Note: The station name must be identical in the configuration and on the local PC station Entry in the Station Configuration Editor. 5. Copy the XDB file onto a data medium that the destination station can access. 6. Import the XDB file into your destination station using the Station Configuration Editor.
30
2.5
Commissioning Wizard
When configuring the SIMATIC NET communications modules for the first time, you are supported by the Commissioning Wizard. The Commissioning Wizard takes you through the necessary steps for commissioning modules and the further steps for commissioning a PC station with configured communication. Tips: S S Refer to the examples in the Quick Start chapters in this manual. The tools and utilities were described in Section 2.2, Station Configuration.
31
2.6
PC Station Wizard
The PC Station Wizard supports you when you create projects in SIMATIC NCM PC. It allows you to acquire the configure data of the PC station automatically. This helps you to make sure that your configuration data is consistent. Tips: S S Refer to the examples in the Quick Start section, Chapters 4 and 5. We have already described the interaction of the tools and utilities in Section 2.2, Station Configuration.
32
33
2.7
Purpose
The Station Configuration Editor is the central management entity for the components of the PC station. Components are the modules and communications tasks of active applications. The Station Configuration Editor can also be used for diagnostic purposes.
Modes
You can use the Station Configuration Editor for the local PC station or for a PC accessible over the network.
34
2.7.1
Notice The components in the configuration list you can edit here must be entered in exactly the same order as in the component image you created in SIMATIC NCM PC with HW Config. If the configurations differ, the configuration data that you download to the PC station from SIMATIC NCM PC will not be adopted correctly.
35
1. First assign a name for the station by clicking the Station button. The name must match the name you assigned to the PC station when you configured the communications with SIMATIC NCM PC. 2. If you want the PC station to be accessible on the network, select the station by clicking the Host button. 3. Create the individual components for your PC station by clicking the Add button. The status display constantly informs you whether the component you have created matches the current hardware configuration and whether it matches any configuration that has already been downloaded.
Note You will find more information on the meaning of the display boxes and the buttons in the integrated help system.
36
2.7.2
Diagnostics Tab
How It Works
The Station Configuration Editor manages a diagnostic buffer in which the PC station components (hardware and software) enter event information. You can use this list to analyze configuration or communication problems.
Note You will find more information on the meaning of the display boxes and the buttons in the integrated help system.
37
38
OPC Server
With the SIMATIC NET OPC Server described here, SIMATIC NET offers you a convenient tool with which your PC applications can write and read process data and receive notification of process events. By creating a configuration, you can specify the behavior of the OPC Server. You then download the configuration data to the PC station with NCM PC. This chapter describes the options available to you when configuring the OPC Server with the NCM PC configuration tool.
39
3.1
Significance of Configuration
S Protocol and
service-dependent properties
40
3.2
The General tab contains the formal parameters for identifying the OPC Server. In the other tabs, you can make parameter settings for the OPC server related to the specific protocols. These parameters are independent of the communication connections or a DP master system that you configure separately. The table below provides you with an overview of the possible parameter settings depending on the protocol or service type.
41
Table 3-1 Parameter / Function Possible Settings / Significance DP Can be set for a specific protocol FDL (SEND/ RECEIVE) x FMS S7 ISO/TCP (SEND/RE CEIVE) x
Here, you make the settings to control updating by the OPC Server. The scan cycle time decides how often the OPC server updates the values of the OPC items.
Access protection
You can specify the access rights to individual variables or variable groups for each specific protocol. You can, for example, prevent variables calculated internally by the controller from being overwritten. As default, no access protection is activated.
VFD
VFD (Virtual Field Device) is the neutral description of a device used in FMS. Communication connections (FMS connections) are then configured for the VFDs. Here, you inform the OPC server of the required VFDs. During configuration, you then assign the VFD to the FMS connection. When accessing variables in the PC application, you also reference the VFD. Extra function: creating the object dictionary Here, you can also create the object dictionary (OD) belonging to a VFD. The FMS variables (name and structure) are defined in the object dictionary.
Here, you can make the settings required for communication for services that do not require specific connection configuration. Special settings for providing the data buffers independent of specific connections.
Please note that the parameters are described in detail in the online help for each individual dialog in NCM PC.
42
3.3
43
FMS Connection
Here, you assign a VFD to the FMS connection; you create VFDs in the properties dialog of the OPC Server. The Options button opens the dialog in which you will find the OPC tab.
44
45
46
4.1
OPCInterface
Communication takes place between two devices or modules. Communication in this sense means the transfer of data between two communication partners with different characteristics, controlling the communication partner, and querying the operating state of the partner. Communication with an ET 200 B is described in detail.
47
4.2
Introduction
This example illustrates how you can connect an ET 200 B DP slave with a CP 5613 in a PC station over PROFIBUS-DP. This section describes the programs used for configuring a PC station and a DP slave. You will also see how to use the OPC Scout program for communication with the OPC Server.
Requirements
If you want to try out the example yourself, you require the following: S S S S S a PC a communication module for PROFIBUS (CP 5613) the SIMATIC NET CD 07/2001 software an ET 200 B DP slave PROFIBUS cabling between the PC module and ET 200 device
48
4.2.1
49
4.2.2
3. 4.
Leave the defaults as they are and click Next. On the next page, confirm the configuration of the modules by clicking Next. This saves the configuration and you can no longer go back.
You have now made the following settings in the dialog: S The module will be used for productive communication with the DP protocol. This requires a configuration that will be created with SIMATIC NCM PC or STEP 7. The module will be initialized with the PROFIBUS address 5. This means that it would be possible to download to the PC station over PROFIBUS from an engineering station with SIMATIC NCM PC or STEP 7. In this example, SIMATIC NCM PC is installed locally and a download over the network is not necessary. Index 4 is the identification number for internal addressing of the module within the PC station. Each configured component of a PC station has a unique index. During configuration, the index can be set using SIMATIC STEP 7/HW Config.
50
4.2.3
2.
Only click the Next button in the Commissioning Wizard dialog when you have completed the configuration.
51
4.2.4
Changing Settings
Activity 1.
2.
52
4.2.5
2.
53
4.2.6
CP 5613 as DP Master
In the STEP 7 project created by the wizard, a SIMATIC PC station was created automatically as an image of the local PC. This PC station already includes the OPC server as the basic component for productive communication and the CP 5613. You require a DP master system so that you can assign DP slaves. For the DP mode, a DP master system must therefore be added to the CP 5613: Activity 1.
2.
54
4.2.7
ET 200B as DP Slave
Activity 1. Open the catalog in the right-hand half of the window if it is not already open. You open the catalog by clicking on the following button:
2.
55
3.
4.2.8
56
4.2.9
Completing Commissioning
Activity 1.
2. 3.
Click the Next button. The last dialog box of the Commissioning Wizard appears. Click the Finish button to complete your work with the wizard.
4.2.10
57
Activity 1. Start the OPC Scout in the Start menu: Start > SIMATIC > SIMATIC NET > PROFIBUS > CP5613_CP5614 > OPC Scout
2.
4.2.11
58
Activity 1.
2.
Double-click on the group entry 5613_DP to open the OPC Browser. In the left-hand pane, you will see the hierarchically arranged name space of the OPC variables.
3.
4.
Select the following OPC items from the appropriate branches in the lefthand window and transfer these variables to the right-hand pane by clicking on the arrow button. The structure displayed and the variable names depend on the names specified in the STEP 7 program. DP:[CP_5613]Slave005IB0,2 DP:[CP_5613]Slave005QB0,2 The items are added to the group after you confirm the dialog with OK.
59
4.2.12
Now double-click on the Value cell of the output byte with the content {0|0} (first table row). A dialog opens in which you can change the value of a variable.
3.
4. -
60
5.1
OPCInterface
Communication takes place between two devices or modules. Communication in this sense means the transfer of data between two communication partners with different characteristics, controlling the communication partner, and querying the operating state of the partner. Communication with an S7-400 station using the S7 protocol (SEND/RECEIVE interface ) is described in detail below.
61
5.2
Introduction
This example illustrates how you can connect an S7-400 programmable controller with a PC station over Industrial Ethernet. This section describes the programs used for configuring a PC station for connecting to an S7-400. You will see how symbolic variables in the S7 program are made available in OPC. You will also see how to use the OPC Scout program that is supplied with the product for communication with the OPC Server.
Requirements
If you want to try out the example yourself, you require the following: S S S S S a PC a communication module for Industrial Ethernet (CP 1613) the SIMATIC NET CD 07/2001 software an S7-400 with a CP 443-1 Industrial Ethernet cabling between the PC module and S7 device
For the S7-400, you require an STEP 7 project. In the project, you specify the hardware configuration and the programs and data blocks and define a symbol table. In the example, you will expand your existing STEP 7 project by adding a PC station and will configure the connection between the PC station and the S7-400.
5.2.1
62
5.2.2
63
3. 4.
Leave the defaults as they are and click Next. On the next page, confirm the configuration of the modules by clicking Next. This saves the configuration and you can no longer go back.
You have now made the following settings in the dialog: S S The module will be used for productive communication. This requires a configuration that will be created with SIMATIC NCM PC or STEP 7. The module will be initialized with the MAC address 08.00.06.01.55.06. This means that it would be possible to download to the PC station over Industrial Ethernet from an engineering station with SIMATIC NCM PC or STEP 7. In this example, SIMATIC NCM PC is installed locally and a download over the network is not necessary. Index 4 is the identification number for internal addressing of the module within the PC station. Each configured component of a PC station has a unique index. During configuration, the index can be set using SIMATIC STEP / HW Config.
64
5.2.3
2.
Only click the Next button in the Commissioning Wizard dialog when you have completed the configuration.
65
5.2.4
Changing Settings
Activity 1.
2.
66
5.2.5
2.
67
5.2.6
2.
68
5.2.7
STEP 7 NetPro
Inserting an S7 Connection
Activity 1.
2.
The S7-400 device is automatically entered as the connection partner and the connection type S7 connection will be set. 3. Confirm this dialog by clicking Apply. You have now configured the connection between the PC station and the S7-400.
69
5.2.8
5.2.9
70
2. 3.
Click the Start button to start the Symbol File Configurator. Click the Next button only after the symbol file has been created with the Symbol File Configurator and the file name of the created file has been entered.
5.2.10
The dialog for selecting a new program opens. 2. Select the STEP 7 project in which the program was defined in the left-hand pane of the window. This is a project you created and contains the PC station and the S7-400 device.
3.
71
4.
5.
Click the OK button. These symbolic names are now extracted from the STEP 7 project and entered in a symbol file. The dialog is closed and the symbolic name space that has been created is displayed in the main window.
6.
Save the symbol file and close the Symbol File Configurator.
5.2.11
Completing Commissioning
Activity 1. When you closed the Symbol File Configurator, the path to the symbol file was entered in the Symbols dialog of the Commissioning Wizard. Now click the Next button. 2. The last dialog box of the Commissioning Wizard appears. Click the Finish button to complete your work with the wizard.
72
5.2.12
2.
73
5.2.13
2.
Double-click on the group entry IE_SAMPLE to open the OPC Browser. In the left-hand pane, you will see the hierarchically arranged name space of the OPC variables.
74
3.
4.
Select the following OPC items from the appropriate branches in the lefthand window and transfer these variables to the right-hand pane by clicking on the arrow button.
The items are added to the group after you confirm the dialog with OK.
75
5.2.14
Now double-click on the Value cell of one of the variables, for example on the 0 of the first OPC item. A dialog opens in which you can change the value of the variable.
3.
4. -
76
Singapore
The languages spoken on the hotlines are German and English. On the authorization hotline, French, Italian and Spanish are also available.
77
Training Center
To help you to become familiar with working with SIMATIC S7 PLCs, we offer a range of courses. Please contact your regional training center or the central training center in D 90327 Nuremberg. Tel. + 499118953154 Infoline: Tel. +49 180 523 5611 (48 Pfg./min), Fax. 0180 523 5612 Internet: E-mail: http://www.ad.siemens.de/training [email protected]
Further Support
If you have further questions about SIMATIC NET products, please contact your local Siemens representative. You will find the addresses: S S In our catalog IK PI On the Internet (http://www.ad.siemens.de)
78
Glossary
Station Configuration Editor The Station Configuration Editor is the user interface of the Station Manager; this allows you access to the component management of the PC station. Here, the components are the modules and the applications involved in communications. The Station Configuration Editor can also be used for diagnostic purposes.
Advanced PC Configuration (APC) As of the SIMATIC NET PC/Windows CD 07/2001, a new standard for PC commissioning is available Advanced PC Configuration. Automatic software installation, Plug and Play for all supported modules, and userguided commissioning are also part of Advanced PC Configuration just as greatly simplified OPC configuration and the new SIMATIC NCM PC configuration tool. SIMATIC NCM PC allows configuration of SIMATIC NET PC components that is compatible with STEP 7 and serves as a substitute for the previous PC configuration tools COML S7 and COM PROFIBUS PC Edition. A common database with STEP 7 ensures comprehensive configuration including all protocols.
79
Glossary
SIMATIC NCM PC SIMATIC NCM PC is a configuration tool that is compatible with STEP 7 and is tailored to the requirements of PC configuration. SIMATIC NCM PC provides the full functionality for the following tasks: Configuring PC stations and networking them graphically Configuring connections Configuring the DP mode (DPV0 and DPV1) Setting network parameters for PROFIBUS Downloading configuration data to PC stations Monitoring communication with attached S7 stations using NCM Diagnostics
Station Manager With the Station Manager, you can configure a PC in much the same way as an S7 station and download the configuration data over the network. The Station Manager is the basic component for configuration and run time of OPC applications.
PC Station In this context, a PC station means a PC with communications modules and applications. The role of this PC might be, for example, to communicate with SIMATIC S7 devices and perform process control tasks. The term runtime station is also used to describe such PCs equipped with runtime software. The PC station is configured for communication with SIMATIC S7 devices in SIMATIC NCM PC / STEP 7. The required runtime software is available on the PC station after installing APC (Advanced PC Configuration).
STEP 7 Project A STEP 7 Project is created with SIMATIC NCM PC or with STEP 7/NCM. It contains the project and configuration data that can be downloaded to S7 stations and PC stations.
80
3
CP 5613 (PCI) CP 5613 FO (PCI)
CP 5614 (PCI)
PC card with its own microprocessor Recommended solution for: } PC-based control systems (Soft Control, PLC, Numeric Control, Robot Control) } Process control systems } Human Machine Interface (HMI) } PROFIBUS systems with a large quantity framework (more than 8 stations) } Multi-protocol operation } Use of several CPs in one computer } Versions with Fiber Optic interface (FO)
You will find software for the PC products under Windows on the SIMATIC NET/Windows-CD including the appropriate manuals in pdf format and other detailed information about SIMATIC NET products and communication. The necessary configuration tools are contained in all software packages
CP 5614 FO (PCI)
CP 5511 (PCMCIA)
CP 5611 (PCI)
PC card without its own microprocessor Recommended solution for: } Configuration tools (e.g. STEP 7) } PROFIBUS-DP diagnostics station (e.g. with COM PROFIBUS or as a DP master class 2) } PROFIBUS-DP slave connection } PROFIBUS systems with up to 8 stations } Monoprotocol mode
Performance
G_IK10_deP0035s
A comparison of event access (via Interrupt) and polling access shows that the CPU loading in CP 5613 can be reduced considerably using the event/filter mechanism; at the same data throughput.
CPU load
Note: The CP 5613 is the successor type to CP 5412 (A2) 1) for credit = 1; PDU size 480 bytes 2) for credit = 1
3/277
PC/Windows NT SIMATIC NET OPC Manager WinCC OPC Client Office 97 OPC Client
DP OPC Server
S7 OPC Server
S7 OPC Server
FMS protocol
DP protocol
S7 communic.
OPC-Scout with Browser function as OPC-Client and OCX-Data-Control (only S7-OPC server)
FMS-PC SIMATIC S7
0 1
SIMATIC S7
ET 200X
G_IK10_deP0040s
SIMATIC S5
PROFIBUS
Ind. Ethernet
S7-PC
Application
Under Windows NT, OPC (OLE for Process Control) can be used as an extension to the communications interfaces COM (Component Object Model) and DCOM (Distributed COM) for the user software. The basic principle of OPC is that OPC client applications can communicate with the OPC server through a standard / open and thus manufacturer-independent interface. Connection to OPC-compatible Windows applications already on the market (Office 97 or HMI systems) is possible.
The following OPC servers are available: PROFIBUS: DP-OPC server for PROFIBUS-DP FMS-OPC server for PROFIBUS-FMS S7-OPC servers for S7 communication, alarms and events as well as S5compatible communication (SEND/RECEIVE) The OPC servers have: Standardized access to SIMATIC S7 and SIMATIC S5 for OPC-compatible applications under Windows NT Consistency between automation products from different manufacturers Efficient data exchange from a process component to a further processing application Simultaneous use of several servers by one client application
The same simple-to-use user interface for different components. Accessibility from every computer in the LAN/WAN High-performance data access via the Custom Interface (C++) Easy to use via the "Automation Interface (VB) or OCX Data Control (S7 and FMS-OPC server only), which is supplied. Grouping of variables (items), whereby a large number of data can be processed in a short time
Functions
Open standardization of addressing using logical names for objects of an automation component or system. Support of symbols from STEP 7
Several clients can run on one OPC server at the same time Server-specific configuration support
Application X
Application Y
3
Fig. 3/106 Comparison of conventional client/server architecture with an OPC architecture
G_IK10_deP0041s
Server A
Server B
Server C
FMS-OPC Server
S7-OPC Server
XY-OPC Server
DP-OPC Server
Configuration
The communications parameters can be completely configured using the tools in the software which is already installed.
The following demo programs are supplied as standard: For custom interface in C++ For "Automation Interface with Visual Basic Easy integration in the system environment and office applications via C++ and Visual Basic interface Short programming times for applications. Easy to handle and costeffective because the OPC servers are supplied with the communication software
Simple use of different networks and protocols through standard interface. Reduced training and learning requirements.
3/279
Product versions
Product DP-5613 S7-5613 FMS-5613 SOFTNET-S7 for PROFIBUS SOFTNET-DP SOFTNET-DP slave CP 5613/5614 and CP 5613 FO/5614 FO with DP-Base software contains OPC servers for: PROFIBUS-DP S7 communication FMS communication S7 communication PROFIBUS-DP PROFIBUS-DP slave S5 compatible communication (FDL) PROFIBUS-DP (master) (in preparation) Access to DP slave of the CP 5614 (in preparation)
Access to
Interfaces
Protocols
Availability
PCI card with microprocessor for system interfacing for PCs and SIMATIC programming devices/PC to PROFIBUS up to 12 Mbit/s Communication services: PROFIBUS-DP master according to IEC 61158/ EN 50170 PG/OP communication with STEP 5 and STEP 7. S7 communication S5-compatible communication (SEND/RECEIVE) on the basis of the FDL interface PROFIBUS-FMS according to IEC 61158/ EN 50170 The CP 5613 enables connection to PROFIBUS for SIMATIC PG/PC and PCs with PCI slot under Windows NT 4.0 and Windows 2000 Professional. Short PCI card 9-pin Sub-D socket for connecting to PROFIBUS Diagnostic LEDs. Parallel operation of max. 4 CPs 1) The module is installed via PCI standard mechanisms (plug & play).
1) FMS-5613 supports a maximum 2 CP 5613/5614.
Extensive diagnostic facilities for installation, commissioning and operation of the module High performance via direct Dual Port-RAM-access Event and filter mechanism for relieving the host CPU. OPC servers are supplied with the communication software
S5 C
FMS
OPC
3
It is connected to the optical PROFIBUS with integrated interface and OBT by: bus cable with 2 bus connectors or 830-1T PROFIBUS connecting cable to an optical bus terminal (OBT) for PROFIBUS-DP. Direct connection to the optical PROFIBUS with integrated interface by CP 5613 FO.
Application
The CP 5613 provides high performance support for control tasks on the PC (e.g. PCbased control, numeric control, robot control). It is connected to the electrical PROFIBUS by bus connector and PROFIBUS bus cable or bus terminal (e.g. 12M bus terminal) and PROFIBUS bus cable. It is connected to the optical PROFIBUS by: bus cable with 2 bus connectors or 830-1T PROFIBUS connecting cable to an OLM. Event/filter mechanism The user receives up-to-date data via two access mechanisms: Cyclic polling of the DP slaves (higher load on host CPU) Signalling by new kind of event/filter mode in the event of changes in the input data of a slave (minimum load on host CPU) Both alternatives can be combined. Optimum utilization of the PC is therefore possible for the application in question.
Design
Functions
PROFIBUS-DP Access to process data with DP-Base The CP 5613 is operated as a PROFIBUS-DP master module which holds the process image (input/output and diagnostic data) in the Dual PortRAM (memory area on the CP). The high-performance data exchange with the PROFIBUS slaves is handled independently by the CP 5613 hardware. The user has direct access to the Dual Port-RAM. The process data of the slaves are always consistent, i.e. the user gets the data from one and the same DP cycle. Parallel operation of DP-Base and DP 5613 software is not possible.
The new event/filter mechanism can be used additionally for Signalling by Interrupt for diagnostic messages from slaves In equidistant mode signalling by interrupt: Start DP cycle End of cyclic data exchange with the DP slaves (from hardware version 3, in preparation) Equidistant mode settable as of STEP 7 V5.1
3/281
http://www.ad.siemens.de/net/dk5613
Configuration
For all packages mentioned above, the configuration tools are included in the scope of supply.
The complete configuration of the S7 communication is performed using STEP 7 V5.0 SP3 and higher. The configurations generated for the PCs using STEP 7 are stored in files which are subsequently transferred to the individual PCs. Therefore a PROFIBUS network can be started up quickly and easily with a CP 5613.
Configuration of PROFIBUSDP and FMS takes place with the enclosed COM PROFIBUS PC-Edition.
Diagnostics
Extensive diagnostic tools are available (for installation, commissioning and operation) for the module itself and for the PROFIBUS network.
3/283
Technical specifications
Baud Rates Interfaces Connection to PROFIBUS 9.6 Kbit/s to 12 Mbit/s 9-pin Sub-D socket 5 V DC 5% 1.3 A 6.5 W
Ordering data
DP-5613/Windows NT 4.0, 2000 Pro Software V2.1 for DP protocol on CP 5613/CP 5614/CP 5613 FO/ CP 5614 FO, incl. PG, FDL and DP-OPC server, with electronic manual; on CD-ROM, German/English S7-5613/Windows NT 4.0, 2000 Pro Software V2.1 for S7 communication on CP 5613/CP 5614/CP 5613 FO/ CP 5614 FO, incl. PG, FDL and S7-OPC server, with electronic manual; on CD-ROM, German/English FMS-5613/Windows NT 4.0, 2000 Pro Software V2.1 for FMS protocol on CP 5613/CP 5614/CP 5613 FO/ CP 5614 FO, incl. PG, FDL and FMS-OPC server, with electronic manual; on CD-ROM, German/English Manual CP 5613/CP 5614 and SOFTNET for PROFIBUS Including: Description of the interfaces (FMS, DP, S7, FDL), OPC server, configuration tools German English PROFIBUS FastConnect RS 485 bus connector Plug 180 With 180 cable outlet
Order No.
6GK1 713-5DB21-3AA0
Supply voltage (from PCI) Power consumption from 5 V Power loss Perm. ambient conditions Operating temperature without fan with fan (air current 0.5 m/s) Transport/storage temperature Relative humidity Design Module format Dimensions (W H) in mm Weight Space required Performance data Single protocol mode Number of connectable DP slaves No. of parallel FDL tasks to be processed No. of PG/OP and S7 connections No. of FMS connections
6GK1 713-5CB21-3AA0
max.
+5 C to +40 C +5 C to +60 C 40 C to +70 C 95% at +25 C PCI card 107 168 250 g 1 PCI slot
6GK1 713-5FB21-3AA0
approx.
} } }
Ordering data
CP 5613 communication processor
Order No.
6GK1 561-3AA00
PCI card for connection to PROFIBUS incl. Windows NT 4.0, 2000 Pro drivers, DP-RAM interface for DP master incl. PG and FDL, configuration software; with electronic manual; on CD-ROM Development Kit DK-5613 Software Development Kit for CP 5613/CP 5614/CP 5613 FO/ CP 5614 FO for integration in any operating system environments on systems with PCI slot Download from Internet under: http://www.ad.siemens.de/net/dk5613
} PROFIBUS bus terminal 12M Bus terminal for connecting PROFIBUS stations up to 12 Mbit/s with connecting cable
SIMATIC NET Software Update Service For Industrial Ethernet, PROFIBUS, OPC server, including manuals, on CD-ROM, German/English Electronics manuals Communication systems, protocols, products on CD-ROM German/English
6GK1 500-0AA10
6GK1 704-0AA00-3AA2
6GK1 975-1AA00-3AA0
PCI card with microprocessor for system interfacing for PCs and SIMATIC PUs/PC to the optical PROFIBUS with integrated interface up to 12 Mbit/s Integrated FOC interface for direct FO connection Communication services: PROFIBUS-DP master according to IEC 61158/ EN 50170 PG/OP communication with STEP 5 and STEP 7. S7 communication S5-compatible communication (SEND/RECEIVE) on the basis of the FDL interface PROFIBUS-FMS according to IEC 61158/ EN 50170
Extensive diagnostic facilities for installation, commissioning and operation of the module High performance via direct Dual Port-RAM access Event and filter mechanism for relieving the host CPU. Multiple protocol operation and parallel operation of up to 4 CPs OPC servers are supplied with the communication software
S5 C
FMS
OPC
Application
The CP 5613 FO enables connection to the optical PROFIBUS with integrated interface for SIMATIC PG/PC and PCs with PCI slot under Windows NT 4.0 and Windows 2000 Professional. Short PCI card 2 Duplex sockets for connection of plastic and PCF FOCs with 2 simplex plugs each to the optical PROFIBUS Connection for external power supply. This means data transmission on the optical line is not interrupted when the PC is switched off. PROFIBUS-DP Access to process data with DP-Base The CP 5613 FO is operated as a PROFIBUS-DP master module which holds the process image (input/output and diagnostic data) in the Dual Port-RAM (memory area on the CP). The high-performance data exchange with the PROFIBUS slaves is handled independently by the CP 5613 FO hardware. The user has direct access to the Dual Port-RAM. The process data of the slaves are always consistent, i.e. the user gets the data from one and the same DP cycle. Parallel operation of DP-Base and DP 5613 software is not possible.
The CP 5613 FO provides high performance support for control tasks on the PC (e.g. PC-based control, numeric control, robot control).
Design
Diagnostic LEDs. Parallel operation of up to 4 CPs. The module is installed via PCI standard mechanisms (plug & play).
It is connected to the optical PROFIBUS with integrated interface by: Plastic and PCF FOCs with simplex plugs. It is connected to the electrical PROFIBUS by Plastic and PCF-FOC with simplex plugs to an OBT.
Functions
Event/filter mechanism The user receives up-to-date data via two access mechanisms: Cyclic polling of the DP slaves (higher load on host CPU) Signalling by new kind of event/filter mode in the event of changes in the input data of a slave (minimum load on host CPU) Both alternatives can be combined. Optimum utilization of the PC is therefore possible for the application in question.
The new event/filter mechanism can also be used for: Signalling by Interrupt for diagnostic messages from slaves In equidistant mode signalling by interrupt: Start DP cycle End of cyclic data exchange with the DP slaves (from hardware version 3, in preparation) Equidistant mode settable as of STEP 7 V5.1
3/285
http://www.ad.siemens.de/net/dk5613
Configuration
For all packages mentioned above, the configuration tools are included in the scope of supply. The complete configuration of the S7 communication is performed using STEP 7 V5.1 and higher. Extensive diagnostic tools are available (for installation, commissioning and operation) for the module itself and for the PROFIBUS network. Fastest possible access to process data via Dual Port-RAM Short response time with FastLogic Process-consistent data from a DP cycle
The configurations generated for the PCs using STEP 7 are stored in files which are subsequently transferred to the individual PCs.
Configuration of PROFIBUSDP and FMS takes place with the enclosed COM PROFIBUS PC-Edition.
Diagnostics
Therefore a PROFIBUS network can be started up quickly and easily with a CP 5613 FO.
Direct connection to the optical PROFIBUS by integrated FOC interface Higher computing performance in the PC by relieving the host CPU. Fast commissioning by Plug&Play and diagnostic tools
Easy portability to other operating systems by a Dual Port-RAM interface Can also be used in a high temperature industrial environment.
3/287
Ordering data
CP 5613 FO communication processor
Order No.
6GK1 561-3FA00
PCI card for connection to PROFIBUS incl. Windows NT 4.0, 2000 Pro drivers, DP-RAM interface for DP master incl. PG and FDL, configuration software; with electronic manual; on CD-ROM Development Kit 1) DK-5613 Software Development Kit for CP 5613/CP 5614 for integration in any operating system environments on systems with PCI slot DP-5613/Windows NT 4.0, 2000 Pro Software V2.1 for DP protocol on CP 5613/CP 5614/CP 5613 FO/ CP 5614 FO, incl. PG, FDL and DP-OPC server, with electronic manual; on CD-ROM, German/English S7-5613/Windows NT 4.0, 2000 Pro Software V2.1 for S7 communication on CP 5613/CP5614/CP 5613 FO/ CP 5614 FO, incl. PG, FDL and S7-OPC server, with electronic manual; on CD-ROM, German/English FMS-5613/Windows NT 4.0, 2000 Pro Software V2.1 for FMS protocol on CP 5613/CP5614/CP 5613 FO/ CP 5614 FO, incl. PG, FDL and FMS-OPC server, with electronic manual; on CD-ROM, German/English Manual CP 5613/CP 5614 and SOFTNET for PROFIBUS Including: Description of the interfaces (FMS, DP, S7, FDL), OPC server, configuration tools German English SIMATIC NET Software Update Service For Industrial Ethernet, PROFIBUS, OPC server, including manuals, on CD-ROM, German/English Electronic manuals Communication systems, protocols, products on CD-ROM German/English 1) Download from Internet under:
6GK1 713-5DB21-3AA0
max.
+5 C to +40 C +5 C to +60 C 40 C to +70 C 95% at +25 C PCI card 107 168 250 g 1 PCI slot
6GK1 713-5CB21-3AA0
approx.
122 120 50 1) 40 2)
6GK1 713-5FB21-3AA0
} } }
6GK1 975-1AA00-3AA0
http://www.ad.siemens.de/net/dk5613
PCI card with microprocessor for system interfacing for PCs and SIMATIC programming devices/IPC to PROFIBUS up to 12 Mbit/s Communication services: PROFIBUS-DP master interface according to IEC 61158/EN 50 170 on a PCI card PROFIBUS-DP slave interface according to IEC 61158/EN 50 170 on a PCI card PG/OP communication with STEP 5 and STEP 7. S7 communication
S5-compatible communication (SEND/RECEIVE) on the basis of the FDL interface PROFIBUS-FMS according to IEC 61158/ EN 50170 High performance via direct Dual Port RAM access Event and filter mechanism for relieving the host CPU. OPC servers are supplied with the communication software
S5 C
FMS
OPC
Application
The CP 5614 enables connection to PROFIBUS for SIMATIC PG/PC and PCs with PCI slot under Windows NT 4.0 and Windows 2000 Professional. It can be either a DP master or a DP slave independently of each other. Short PCI card 2 9-pin Sub-D sockets for connecting to PROFIBUS Diagnostic LEDs. Parallel operation of up to 4 CPs. The module is installed via PCI standard mechanisms (plug & play).
This means that two different PROFIBUS networks can be connected to a PC in a hierarchic structure using one PROFIBUS card and data can be exchanged between the networks.
The CP 5614 provides high performance support for control tasks on the PC (e.g. PC based control, numeric control, robot control).
Design
It is connected to the electrical PROFIBUS by bus connector and PROFIBUS bus cable or bus terminal (e.g. 12M bus terminal) and PROFIBUS bus cable. It is connected to the optical PROFIBUS by bus cable with 2 bus connectors or 830-1T PROFIBUS connecting cable to an OLM. Parallel operation of DP 5613 (DP master) and DP-Base (DP master, DP slave) is not possible. Event/filter mechanism The user receives up-to-date data via two access mechanisms: Cyclic polling of the DP slaves (higher load on host CPU) Signalling by new kind of event/filter mode in the event of changes in the input data of a slave (minimum load on host CPU)
It is connected to the optical PROFIBUS with integrated interface and OBT by: bus cable with 2 bus connectors or 830-1T PROFIBUS connecting cable to an optical bus terminal (OBT) for PROFIBUS. Direct connection to the optical PROFIBUS with integrated interface by CP 5614 FO.
Functions
PROFIBUS-DP Access to process data The CP 5614 is operated as a PROFIBUS-DP master and DP slave module which holds the process image (input/output and diagnostic data) in the Dual Port-RAM. The high-performance data exchange with the PROFIBUS slaves is handled independently by the CP 5614 FO hardware. The user has direct access to the Dual Port-RAM. The process data of the slaves are always consistent, i.e. the user gets the data from one and the same DP cycle.
Both alternatives can be combined. Optimum utilization of the PC is therefore possible for the application in question. The new event/filter mechanism can also be used for: Signalling by Interrupt for diagnostic messages from slaves In equidistant mode signalling by interrupt: Start DP cycle End of cyclic data exchange with the DP slaves (from hardware version 3, in preparation) Equidistant mode settable as of STEP 7 V5.1
3/289
http://www.ad.siemens.de/net/dk5613
3/291
Diagnostics
Extensive diagnostic tools are available (for installation, commissioning and operation) for the module itself and for the PROFIBUS network. Only 1 slot is required for a master and slave. Fastest possible access to process data via Dual PortRAM Short response time with FastLogic
Process-consistent data from a DP cycle Higher computing performance in the PC by relieving the host CPU. Fast commissioning by Plug&Play and diagnostic tools
Easy portability to other operating systems by a Dual Port-RAM interface Can also be used in a high temperature industrial environment.
PROFIBUS
Transfer mechanism DP slave RS 485 DP master CP 5614 Distributed I/O
PROFIBUS
SIMATIC ET 200M
SIMATIC ET 200S
G_IK10_deP0110s
Ordering data
DP-5613/Windows NT 4.0, 2000 Pro Software V2.1 for DP protocol on CP 5613/CP 5614/CP 5613 FO/ CP 5614 FO, incl. PG, FDL and DP-OPC server, with electronic manual; on CD-ROM, German/English S7-5613/Windows NT 4.0, 2000 Pro Software V2.1 for S7 communication on CP 5613/CP5614/CP 5613 FO/ CP 5614 FO, incl. PG, FDL and S7-OPC server, with electronic manual; on CD-ROM, German/English FMS-5613/Windows NT 4.0, 2000 Pro Software V2.1 for FMS protocol on CP 5613/CP5614/CP 5613 FO/ CP 5614 FO, incl. PG, FDL and FMS-OPC server, with electronic manual; on CD-ROM, German/English Manual CP 5613/CP 5614 and SOFTNET for PROFIBUS Including: Description of the interfaces (FMS, DP, S7, FDL), OPC server, configuration tools German English PROFIBUS FastConnect RS 485 bus connector Plug 180 With 180 cable outlet Order No. 6GK1 561-4AA00
Order No.
6GK1 713-5DB21-3AA0
6GK1 713-5CB21-3AA0
max.
+5 C to +40 C +5 C to +60 C 40 C to +70 C 95% at +25 C PCI card 107 168 300 g 1 PCI slot
6GK1 713-5FB21-3AA0
approx.
max.
122
120 50 1) 402)
} } }
Ordering data
} Communication processor CP 5614 PCI card with master and slave connection to PROFIBUS, incl. Windows NT 4.0, 2000 Pro drivers, DP-RAM Interface for DP master and slave, PG and FDL, configuration software with electronic manual on CD-ROM
Development Kit 1) DK-5613 Software Development Kit for CP 5613/CP 5614 for integration in any operating system environments on systems with PCI slot 1) Download from Internet under:
} PROFIBUS bus terminal 12M Bus terminal for connecting PROFIBUS stations up to 12 Mbit/s with connecting cable
SIMATIC NET Software Update Service For Industrial Ethernet, PROFIBUS, OPC server Including manuals, on CD-ROM, German/English Electronic manuals Communication systems, protocols, products on CD-ROM German/English
6GK1 500-0AA10
6GK1 704-0AA00-3AA2
6GK1 975-1AA00-3AA0
http://www.ad.siemens.de/net/dk5613
3/293
PCI card with microprocessor for system interfacing for PCs and SIMATIC PUs/PC to the optical PROFIBUS with integrated interface up to 12 Mbit/s Integrated FOC interface for direct FO connection Communication services: PROFIBUS-DP master interface according to IEC 61158/EN 50 170 on a PCI card PROFIBUS-DP slave interface according to IEC 61158/EN 50 170 on a PCI card PG/OP communication with STEP 5 and STEP 7.
S5 C
FMS
OPC
S7 communication S5-compatible communication (SEND/RECEIVE) on the basis of the FDL interface PROFIBUS-FMS according to IEC 61158/ EN 50170 High performance via direct Dual Port RAM access Event and filter mechanism for relieving the host CPU. Multiple protocol operation and parallel operation of up to 4 CPs OPC servers are supplied with the communication software The CP 5614 FO provides high performance support for control tasks on the PC (e.g. PC-based control, numeric control, robot control).
3
Application The CP 5614 FO enables connection to PROFIBUS-DP for SIMATIC PG/PC and AT-compatible PCs with PCI slot under Windows NT 4.0 and Windows 2000 Professional. Design Short PCI card 2 Duplex sockets for connection of plastic and PCF FOCs with 2 simplex plugs each to the optical PROFIBUS 9-pin Sub-D socket for connecting to PROFIBUS Connection for external power supply. This means data transmission on the optical line is not interrupted when the PC is switched off. PROFIBUS-DP Access to process data The CP 5614 is operated as a PROFIBUS-DP master and slave module which holds the process image (input/output and diagnostic data) in the Dual Port-RAM. The high-performance data exchange with the PROFIBUS slaves is handled independently by the CP 5614 FO hardware. The user has direct access to the Dual Port-RAM. The process data of the slaves are always consistent, i.e. the user gets the data from one and the same DP cycle. Parallel operation of DP 5613 (DP master) and DP-Base (DP master, DP slave) is not possible.
It can be either a DP master or a DP slave independently of each other. In this way two different PROFIBUS networks can be connected in a hierarchical structure to one PC with a PROFIBUS card and can exchange data. Diagnostic LEDs. Parallel operation of up to 4 CPs. The software can switch assignment of master and slave to the optical and electrical interface. The module is installed via PCI standard mechanisms (plug & play).
It is connected to the optical PROFIBUS with integrated interface and OBT by: Plastic and PCF FOCs with simplex plugs. It is connected to the electrical PROFIBUS by Plastic and PCF-FOC with simplex plugs to an OBT.
Functions
Event/filter mechanism The user receives up-to-date data via two access mechanisms: Cyclic polling of the DP slaves (higher load on host CPU) Signalling by new kind of event/filter mode in the event of changes in the input data of a slave (minimum load on host CPU) Both alternatives can be combined. Optimum utilization of the PC is therefore possible for the application in question. The new event/filter mechanism can also be used for:
Signalling by Interrupt for diagnostic messages from slaves In equidistant mode signalling by interrupt: Start DP cycle End of cyclic data exchange with the DP slaves (from hardware version 3, in preparation) Equidistant mode settable as of STEP 7 V5.1 FastLogic (rapid shutdown) FastLogic means that the CP5614 FO can react automatically to up to 4 plant states. A fast response time and independence of the host application is achieved here e.g. fast switch off of devices.
3/295
http://www.ad.siemens.de/net/dk5613
Diagnostics
Extensive diagnostic tools are available (for installation, commissioning and operation) for the module itself and for the PROFIBUS network. Only 1 slot is required for a master and slave. Direct connection to the optical PROFIBUS by integrated FOC interface Fastest possible access to process data via Dual PortRAM Short response time with FastLogic
Process-consistent data from a DP cycle Higher computing performance in the PC by relieving the host CPU Easy portability to other operating systems by a Dual Port-RAM interface
Can also be used in a high temperature industrial environment Flexible application by switchable assignment of optical and electrical interface to master and slave
optical PROFIBUS
Transfer mechanism DP slave DP master CP 5614 FO Distributed I/O FO RS 485 Switchable
PROFIBUS
SIMATIC ET 200M
SIMATIC ET 200S
3/297
G_IK10_deP0109s
Ordering data
Development Kit 1) DK-5613 Software Development Kit for CP 5613/CP 5614 for integration in any operating system environments on systems with PCI slot DP-5613/Windows NT 4.0, 2000 Pro Software V2.1 for DP protocol on CP 5613/CP 5614/CP 5613 FO/ CP 5614 FO, incl. PG, FDL and DP-OPC server, with electronic manual; on CD-ROM, German/English S7-5613/Windows NT 4.0, 2000 Pro Software V2.1 for S7 communication on CP 5613/CP 5613 FO/ CP 5614/CP 5614 FO, incl. PG, FDL and S7-OPC server, with electronic manual on CD-ROM, German/English FMS-5613/Windows NT 4.0, 2000 Pro Software V2.1 for FMS protocol on CP 5613/CP 5613 FO/ CP 5614/CP 5614 FO, incl. PG, FDL and FMS-OPC server, with electronic manual on CD-ROM, German/English PROFIBUS FastConnect RS 485 bus connector Plug 180 PROFIBUS bus terminal 12M PROFIBUS plastic fiber optic, simplex plug / polishing set PROFIBUS plastic fiber optic, stripping tool set Connection adapters 50 pieces Manual CP 5613/CP 5614 and SOFTNET for PROFIBUS Including: Description of the interfaces (FMS, DP, S7, FDL), OPC server, configuration tools German English SIMATIC NET Software Update Service For Industrial Ethernet, PROFIBUS, OPC server Including manuals, on CD-ROM, German/English Electronic manuals Communication systems, protocols, products on CD-ROM German/English 1) Download from Internet under:
Order No.
6GK1 713-5DB21-3AA0
9-pin Sub-D socket 2 Duplex socket (FO) Low voltage socket 3.5 mm/1.3 mm + 5 V DC 5% 12 V DC 5% 1.6 A 0.3 A 8W 9 12 V DC 0.4 A 3.6 4.8 W
6GK1 713-5CB21-3AA0
6GK1 713-5FB21-3AA0
max.
+5 C to +40 C +5 C to +60 C 40 C to +70 C 95% at +25 C PCI card 107 168 300 g 1 PCI slot
} } } } }
6GK1 500-0FC00
approx.
max.
122
120 50 1) 40 2)
} } }
Ordering data
} CP 5614 FO communication processor PCI card with master and slave connection to PROFIBUS, incl. Windows NT 4.0, 2000 Pro drivers, DP-RAM interface for DP master and slave, configuration software with electronic manual on CD-ROM
6GK1 975-1AA00-3AA0
http://www.ad.siemens.de/net/dk5613
For connecting PG/PCs and notebooks with PCMCIA slot to PROFIBUS and MPI of the SIMATIC S7 Communication services: PROFIBUS-DP master class 1 with SOFTNET-DP. PROFIBUS-DP master class 2 including acyclic DP expansions with SOFTNET-DP. PROFIBUS-DP slave with SOFTNET-DP slave. PG/OP communication S7 communication with SOFTNET-S7. S5-compatible communication (SEND/RECEIVE based on the FDL interface) with SOFTNET-DP or SOFTNET-S7. The CP 5511 enables connection of programming devices and AT-compatible PCs to PROFIBUS and to the multipoint interface (MPI) of SIMATIC S7: PCMCIA card type II Adapter with 9-pin Sub-D socket for connection to PROFIBUS The CP 5511 is operated under different software packages and allows the user to execute programming device functions and PC functions via PROFIBUS and the multipoint interface (MPI). Only one CP can be operated for each PG/PC/notebook. Similarly only one protocol (PROFIBUS-DP, S7 communication or FDL) can be used for each CP. The following software packages support the CP 5511: STEP 7 as of V3.2 Drivers for the CP 5511 are supplied with STEP 7 SOFTNET-S7 The S7 programming interface can be used with this package SOFTNET-DP With this the CP 5511 can be used as a PROFIBUS-DP master class 1 or 2 SOFTNET-DP slave for using the CP 5511 as a PROFIBUS-DP slave for connecting PCMCIA slot and notebooks
PCMCIA card type II; for PG/PCs with PCMCIA slot and notebooks Used with: STEP 7, ProTool, Micro/Win, ProTool/Pro, SIMATIC PDM (for PG/OP communication) COM PROFIBUS SOFTNET-S7 (for S7 communication). SOFTNET-DP (for DP). OPC servers are supplied with the communication software
S5 C
FMS
OPC
Application
Design
Functions
COM PROFIBUS as of V3.3 With this package the CP 5511 can be used for commissioning or diagnostics (DP online functions) for PROFIBUS-DP systems STEP 7-Micro/Win as of V2.1 Hardware base for the programming software of the SIMATIC S7-200 programmable controller ProTool, ProTool/PRO The CP 5511 can be used as the hardware basis for the configuration tool for SIMATIC operator panels, touch panels and text displays.
3/299
Technical specifications
Data transfer rate Interfaces Connection to PROFIBUS Connection to PG/PC 9.6 Kbit/s to 12 Mbit/s 9-pin Sub-D socket PCMCIA slot type II +5 V DC 5% typ. 270 mA, max. 360 mA 1.8 W +5 C to +40 C 20 C to +60 C 95% at +25 C PCMCIA type II 54 85 5 30 g 130 g 1 PCMCIA slot type II
Ordering data
Communication processor CP 5511 PCMCIA card for connecting a PG or PC to PROFIBUS or MPI SOFTNET-S7/Windows 98, NT 4.0, 2000 Pro Software V5.3 for S7 communication incl. FDL and S7-OPC server, with electronic manual on CD-ROM SOFTNET-DP/Windows 98, NT 4.0, 2000 Pro Software V5.3 for DP protocol incl. FDL and DP-OPC server, with electronic manual on CD-ROM SOFTNET-DP slave/Windows 98, NT 4.0, 2000 Pro Software V1.2 for DP slave, incl. OPC server, with electronic manual on CD-ROM PROFIBUS FastConnect RS 485 bus connector Plug 180 With 180 cable outlet Manual CP 5613/CP 5614 and SOFTNET for PROFIBUS Including: Description of the interfaces (FMS, DP, S7, FDL), OPC server, configuration tools German English SIMATIC NET Software Update Service For Industrial Ethernet, PROFIBUS, OPC server, including manuals, on CD-ROM, German/English Electronics Manuals Communication systems, protocols, products on CD-ROM German/English
Order No.
6GK1 551-1AA00
Supply voltage Current consumption Power loss Perm. ambient conditions Operating temperature Transport/storage temperature Relative humidity
6GK1 704-5CW53-3AA0
6GK1 704-5DW53-3AA0
max.
Design Module format Dimensions (W H D) in mm Weight without adapter approx. with adapter approx. Space required
6GK1 704-5SW12-3AA0
6GK1 500-0FC00
} } }
6GK1 975-1AA00-3AA0
For connecting PG/PC to PROFIBUS and MPI of the SIMATIC S7 Communication services: PROFIBUS-DP master class 1 with SOFTNET-DP. PROFIBUS-DP master class 2 including acyclic DP expansions with SOFTNET-DP. PROFIBUS-DP slave with SOFTNET-DP slave. PG/OP communication S7 communication with SOFTNET-S7. S5-compatible communication (SEND/RECEIVE on the basis of the FDL interface) with SOFTNET-DP or SOFTNET-S7 The CP 5611 enables the connection of programming devices and PCs to PROFIBUS and multipointcapable MPI interface of the SIMATIC S7. Short PCI card 9-pin Sub-D socket for connection to PROFIBUS The CP 5611 is operated under different software packages and allows the user to execute programming device functions and PC functions via PROFIBUS and the multipoint interface (MPI). Only one CP can be operated for each programming device/PC. Similarly only one protocol (PROFIBUS-DP, S7 communication or FDL) can be used for each CP. The following software packages support the CP 5611: STEP 7 V3.2 upwards under Windows 95 and NT 4.0; Windows 98 from V4.02 and K4.02.5. Drivers for the CP 5611 are included in the scope of supply of STEP 7. SOFTNET-S7 The S7 programming interface can be used with this package SOFTNET-DP With this the CP 5611 can be used as a PROFIBUS-DP master class 1 or 2 SOFTNET-DP slave For using the CP 5611 as a PROFIBUS-DP slave For PUs/PCs with PCI slot.
Short PCI card for programming device / PC with PCI slot. Used with: STEP 7, STEP 7-Micro/Win, ProTool, ProTool/Pro, SIMATIC PDM (for PG/OP communication) COM PROFIBUS SOFTNET-S7 (for S7 communication). SOFTNET-DP (for DP). OPC servers are supplied with the communication software
S5 C
FMS
OPC
Application
Design
Functions
COM PROFIBUS as of V3.3 The CP 5611 can be used with this package for commissioning or diagnostics (DP online functions) for PROFIBUS-DP systems STEP 7-Micro/Win as of V2.1 Hardware base for the programming software of the SIMATIC S7-200 programmable controller ProTool, ProTool/PRO The CP 5611 can be used as the hardware basis for the configuration tool for SIMATIC operator panels, touch panels and text displays.
3/301
Technical specifications
Data transfer rate Interfaces Connection to PROFIBUS 9.6 Kbit/s to 12 Mbit/s 9-pin Sub-D socket +5 V DC 5% 0.5 A 2.0 W +5 C to +40 C 20 C to +60 C 95% at +25 C PCI card 102 130 100 g 1 PCI slot
Ordering data
CP 5611 communication processor PCI card for connecting a PG or PC to PROFIBUS CP 5611 MPI Consists of PCI card CP 5611 and MPI cable, 5 m SOFTNET-S7/Windows 98, NT4.0, 2000 Pro Software V5.3 for S7 communication incl. FDL and S7-OPC server, with electronic manual on CD-ROM SOFTNET-DP/Windows 98, NT 4.0, 2000 Pro Software V5.3 for DP protocol incl. FDL and DP-OPC server, with electronic manual on CD-ROM SOFTNET-DP slave/Windows 98, NT 4.0, 2000 Pro Software V1.2 for DP slave interface, with electronic manual on CD-ROM PROFIBUS FastConnect RS 485 bus connector Plug 180 With 180 cable outlet
Order No.
6GK1 561-1AA00
Supply voltage Current consumption Power loss Perm. ambient conditions Operating temperature Transport/storage temperature Relative humidity Design Module format Dimensions (H x D) in mm Weight Space required
6GK1 561-1AM00
6GK1 704-5CW53-3AA0
max.
6GK1 704-5DW53-3AA0
approx.
6GK1 704-5SW12-3AA0
6GK1 500-0FC00
} PROFIBUS bus terminal 12M Bus terminal for connecting PROFIBUS stations up to 12 Mbit/s with connecting cable
Manual CP 5613/CP 5614 and SOFTNET for PROFIBUS Including: Description of the interfaces (FMS, DP, S7, FDL), OPC server, configuration tools German English SIMATIC NET Software Update Service For Industrial Ethernet, PROFIBUS, OPC server, including manuals, on CD-ROM, German/English Electronic manuals Communication systems, protocols, products on CD-ROM German/English
6GK1 500-0AA10
} } }
6GK1 975-1AA00-3AA0
CP 5611
CP 5511
PG/PC
S5 C
FMS
OPC
Can be used in conjunction with CP 5511 (PCMCIA), CP 5611 (PCI) and integrated PROFIBUS interface of the SIMATIC PG/PC/PC Communication services: PROFIBUS-DP master class 1 PROFIBUS-DP master class 2 with non-cyclic expansions PROFIBUS-DP slave PG/OP communication S7 communication S5-compatible communication (SEND/RECEIVE based on the FDL interface)
PROFIBUS
G_IK10_deP0039s
Application
SOFTNET for PROFIBUS can be used to connect PCs to automation systems, e.g. SIMATIC S7, via PROFIBUS. The following are available as user interfaces:
DP protocol PG/OP communication for SIMATIC S7 S7 communication S5-compatible communication (SEND/RECEIVE based on the FDL interface) This architecture means that, unlike CP 5613 or CP 5614 products the performance capability of the SOFTNET Devices of this type (programming devices, configuration devices or operating devices) are used on startup, on configuring the DP system or for operating the system during normal operation (e.g. diagnostics). The DP programming interface provides the following services: Master diagnostics, slave diagnostics, reading the inputs and outputs of a slave, reading configuration data and changing the slave address. The extended DP functions also include noncyclic access to the parameters and measured values of a slave (e.g. field devices of the process automation, intelligent HMI devices. This type of slave must be supplied with extensive parameter data during startup and normal operation (DS_READ, DS_WRITE, DS_DATA_TRANSPORT).
SOFTNET is available for the following interfaces: CP 5511 (PCMCIA card) CP 5611 (PCI card) Integrated PROFIBUS interfaces of SIMATIC programming devices/PCs. packages depends on the construction and / or the workload of the PCs used.
Principle of operation
Functions
Software for DP protocol (SOFTNET-DP) DP master class 1 SOFTNET-DP offers DP master class 1 functions in conjunction with the CP 5511 or CP 5611. In a fixed, repetitive message cycle, the central controller exchanges information with the DP slaves (e.g. ET 200S). The DP programming interface (DPLib.DLL) provides the PC programmer with function calls for data transfer. In addition, the DP interface offers the functions SYNC and FREEZE as well as the activation and deactivation of slaves. DP master class 2 In addition to DP master class 1 services, SOFTNETDP also offers DP master class 2 services.
DP slave (SOFTNET-DP slave) A DP slave is an I/O device that reads input information and supplies output information to the I/O. The quantity of input and output information depends on the type of device and can be up to 244 bytes. The slave applications can be implemented on the PC using the functions SET_INPUT and SET_OUTPUT of the slave programming interface. Configuration of PROFIBUSDP takes place with the enclosed COM PROFIBUS PC-Edition. For the slave interface, an example GSD file is provided which can be adapted to the relevant application.
3/303
Ordering data
DP interface
Order No.
} SOFTNET-DP/Windows 98, NT 4.0, 2000 Pro Software V5.3 for DP protocol incl. FDL protocol and DP-OPC server, with electronic manual on CD-ROM
S7 communication SOFTNET-S7/Windows 98, } NT 4.0, 2000 Pro Software V5.3 for S7 communication incl. FDL protocol and S7-OPC server, with electronic manual on CD-ROM SOFTNET-DP slave/Windows 98, NT 4.0, 2000 Pro Software V1.2 for DP slave interface, with electronic manual on CD-ROM Manual CP 5613/CP 5614 and SOFTNET for PROFIBUS Including: Description of the interfaces (FMS, DP, S7, FDL), OPC server, configuration tools German English SIMATIC NET Software Update Service For Industrial Ethernet, PROFIBUS, OPC server, including manuals, on CD-ROM, German/English Electronic manuals Communication systems, protocols, products on CD-ROM German/English
6GK1 704-5DW53-3AA0
6GK1 704-5CW53-3AA0
6GK1 704-5SW12-3AA0
} } }
6GK1 975-1AA00-3AA0
3/305
Industrial Ethernet
System interfacing for PG/PC
Overview
System interfacing for PG/PC
You can find software for the PC products under Windows on the SIMATIC NET/Windows CD including the appropriate manuals in pdf format and extensive further information about SIMATIC NET products and communication. The necessary configuring tools are supplied with all software packages.
Protocol software runs on the CP Free PC resources for applications Suitable for extensive applications Recommended for applications with HMI systems with high performance requirements, e.g. WinCC Recommended for largescale systems (5 stations and more, e.g. SIMATIC) Constantly high communication thruput Use for redundant communication Time synchronization
CP 1411 (ISA)
CP 1511 (PCMCIA)
4/111
Industrial Ethernet
System interfacing for PG/PC
Overview
Data throughput Industrial Ethernet A comparison between CP 1413, CP 1411, CP 1511, CP 1413 (predecessor to CP 1613) and CP 1613 shows the course of the respective communication performance. This course fluctuates in CP 1411 and CP 1511 with the appropriate software packages between 0 and the maximum throughput. Used with software packages, communication performance for the CP 1613 is stable and high, permitting fast response times without fluctuations.
Time
1)
Mess./sec.
CPU load
The communication must share the PC resources with other applications (especially HMI). In general, therefore, less than 25% of the host CPU time remains available for communication.
Whereas, under these conditions, e.g. the CP 1411/1511 only lets through an average of about 80 messages (with a strongly fluctuating curve), the CP 1613 still offers maximum throughput.
Mess./sec.
25%
CPU load
CP 1413
CP 1411 CP 1511
CP 1613
G_IK10_deI0038s
Industrial Ethernet
Introduction
System interfacing for PG/PC; OPC server
Overview OPC servers are contained in the scope of supply of the communication software Standardized, open and vendor-independent interface. Connection of OPC-capable Windows applications to S7 communication and S5compatible communication (SEND/RECEIVE). Builds on the software programming interfaces. Efficient data exchange for Windows NT 4.0 and Windows 2000 Pro
S7-400 FMS-PC SIMATIC S5 (SEND/RECEIVE only)
PC/Windows NT and Windows 2000 Pro SIMATIC NET OPC Manager WinCC OPC Client Office 97 OPC Client
FMS-OPC Server
DP-OPC Server
S7-OPC Server
S7-OPC Server
FMS Protocol
DP Protocol
S7 Communic.
S7-300
OPC-Scout with browser function as OPC client and OCX data control (only S7 OPC server)
0 1
ET 200X
SIMATIC S5
PROFIBUS
Ind. Ethernet
S7-PC
G_IK10_deI0067s
4
Identical and easy-to-operate user interface for different components. Can be accessed from every computer in the LAN/WAN. High-performance data access via the Custom Interface (C++). Easy to use via the automation interface (VB) or the OCX data control supplied (S7 and FMS OPC server only).
Application
Under Windows NT and Windows 2000 Professional, OPC (OLE for Process Control) can be used as an extension to the communications interfaces COM (Component Object Model) and DCOM (Distributed COM) for the user software. The basic principle of OPC is that OPC client applications can communicate with the OPC server through a standard/open and thus multi-vendor interface. Facility for linking to existing OPC-capable Windows applications (Office 97 or HMI systems) on the market.
For Industrial Ethernet, the following OPC servers are available: S7 OPC servers for S7 communciation, alarms and events as well as S5-compatible communciation (SEND/RECEIVE) The OPC servers offer the following: Standardized access to SIMATIC S7 and SIMATIC S5 for OPC-capable applications under Windows NT and Windows 2000 Professional Integration between automation products from different manufacturers. Simultaneous utilization of two or more servers by one client application. Simultaneous execution of two or more clients on one OPC server application. Server-specific configuration support. Interfaces Custom interface for high-performance C++ applications.
Functions
Open standardization of addressing via logical names for objects contained in an automation component or automation system. Support of symbols from STEP 7 Efficient data exchange between a process component and a further processing application
Automation interface for easily created Visual Basic or comparable applications. OCX data control for direct integration in Windows applications that support COM/DCOM (S7 OPC server only).
4/113
Industrial Ethernet
Introduction
System interfacing for PG/PC; OPC server
Application X
Application Y
Configuration
The communications parameters can be completely configured using the tools in the software which is already installed. Different networks and protocols can be easily implemented due to the uniform interface. Low training and familiarization costs.
The following demo programs are included in the scope of supply: For custom interface in C++ Easy integration in the system environment and office applications via C++ and Visual Basic interface Applications can be generated quickly.
Easy to handle and costeffective because the OPC servers are supplied with the communication software
Product versions
Product S7-1613 TF-1613 SOFTNET-S7 Industrial Ethernet contains OPC servers for: S7 communication S5-compatible communications S5-compatible communications S7 communication
Access to
Interfaces
Protocols
Availability
G_IK10_deP0041s
Server A
Server B
Server C
FMS-OPC Server
S7-OPC Server
XY-OPC Server
DP-OPC Server
Industrial Ethernet
System interfacing for PG/PC
CP 1613 communication processor
Overview
ISO TCP/IP PG/OP S7 C
PCI card with microprocessor for connecting PG/PC to Industrial Ethernet with 10/100 Mbit/s autosensing Communication services via ISO or TCP/IP transport protocols PG/OP communication S7 communication S5-compatible communication (SEND/RECEIVE) TF protocol
OPC servers are supplied with the communication software. 15-pin AUI/ITP RJ45 connection ISO and TCP/IP transport protocol onboard Large quantity framework (up to 160 connections with ISO, up to 64 connections with TCP/IP)
S5 C
IT
TF
OPC
Application
10 Mbit/s
Triaxial network
Bus connector (Transceiver)
4
Connecting cable 727-1 (drop cable) up to 50 m CP 1613
10/100 Mbit/s
AUI ITP
RJ45
10/100 Mbit/s
Structured cabling acc. to EN 50173 Twisted Pair Switch (e.g. ESM TP80)
FC Outlet RJ45
FC Outlet RJ45
4/115
Industrial Ethernet
System interfacing for PG/PC
CP 1613 communication processor
Design The CP 1613 module (card with microprocessor) is plugged directly into a SIMATIC PG/ PC or a PC and requires a short PCI slot. Connections: 15-pin Sub-D socket for use in industrial applications (automatic switching between AUI, ITP and RJ45 interface) RJ45 for connection in the office environment The module is connected forexample for electrical networks via a 727-1 connecting cable/bus coupler to the 727-0 bus. for ITP via the ITP standard cable 9/15 to OSM/ESM/ star coupler for optical networks via the Mini OTDE optical transceiver. The data transfer between the host system and the CP 1613 is handled by a Windows NT driver or Windows 2000 Pro driver. The transfer rate is detected and automatically switched over (autosensing). Software for PG/OP communication This software permits programming of SIMATIC S5 and S7 PLCs via Industrial Ethernet in combination with STEP 5/STEP 7 automation systems. It is contained in all CP 1613 software packages.
Application
The module independently processes the protocols up to and including level 4 (transport). To permit a large number of connections and high communication integrity, 16 Mbytes of memory are provided. User interfaces OPC interface The OPC server contained in the respective software package can be used as a standard programming interface for the protocols S7 communication and S5compatible communication to connect automation applications to OPC-capable Windows applications (Office, HMI systems etc.).
The data exchange between module and host takes place in master mode. This means that the CP 1613 accesses the physical RAM of the host.
Functions
Programming interface via C library The programming interfaces for the protocols S7 communciation, PG/OP communication, S5-compatible communication and TF protocol for existing applications are implemented as a Dynamic Link Library (DLL). The following compilers can therefore be used in conjunction with the SIMATIC NET products: Microsoft Visual C/C++ V6.0 Microsoft Visual Basic V6.0
Industrial Ethernet
System interfacing for PG/PC
CP 1613 communication processor
Functions (continued) Software for S7 communication (S7-1613 or S7-REDCONNECT) The S7 programming interface enables PG/PC applications (e.g. WinCC) and application programs access to SIMATIC S7/M7 system components. Thus, easy and flexible access to the data of the SIMATIC S7/M7 is possible. S7 communication provides: Administrative services Link management. Mini database. Trace. Data transfer services READ/WRITE variables. BSEND/BRECEIVE With S7-REDCONNECT, communication with the highavailability S7-400H system is possible. Software for S5-compatible communication (SEND/RECEIVE) This layer 4 based interface is used for communication between PG/PC and SIMATIC S5 PG/PC and SIMATIC S7 PG/PC and PG/PC . S5-compatible communication (SEND/RECEIVE) provides the following services: Management services Connection buildup service Data transfer services The software is contained in the products S7-1613 and TF-1613. Software for TF protocol (TF-1613) The technological functions interface offers access to the MAP 3.0 open and wellproven automation protocol on Ethernet. The Technological Functions correspond in functionality to the international MMS services in accordance with ISO IS 9506. MMS/TF services: Variable services Domain services Program invocation services General services for virtual devices (VMD support service) Services of TF link management (environment and general management services).
Further details are available in the Internet.
4
http://www.ad.siemens.de/net/ik-info
Configuration
The configuration settings for PCs made with STEP 7 are stored in files that are then transferred to the individual PCs. Free computer capacity for further applications in the PC, e.g. HMI (ISO and TCP/IP transport onboard) Simple handling through plug & play and autosensing (10/100 Mbit/s). Operation of large network configurations with one card due to large number of connections Can be used for redundant communication OPC as common interface
Continuous data throughput through protocol processing on the CP. Can be connected to any Ethernet network via AUI/ITP or RJ45 ports on the module.
4/117
Industrial Ethernet
System interfacing for PG/PC
CP 1613 communication processor
Technical specifications
Transmission rate Interfaces Connection to Industrial Ethernet (10/100 Mbit/s) 10BaseT, 100BaseTX Supply voltage Current consumption from 5 V DC from 12 V DC Power loss Perm. ambient conditions Operating temperature Transportation/storage temperature Relative humidity max. Construction Module format Dimensions (W D) in mm Weight Space requirements Single protocol mode performance data S7 and PG/OP communication No. of operable connections ISO TCP/IP S5-compatible communication (SEND/RECEIVE) No. of operable connections ISO TCP/IP 10/100 Mbit/s 15-pin Sub-D socket (autom. switching between AUI and twisted pair) RJ45 5 V DC 5% 12 V DC 5% 600 mA 500 mA 4W +5 C to +40 C 20 C to +60 C 95% at +25 C Short AT format 107 167 200 g 1 PCI slot
Ordering data
CP 1613 PCI card for connection to Industrial Ethernet (10/100 Mbit/s) with AUI/ITP and RJ45 port S7-1613/Windows NT 4.0, 2000 Pro V2.1 Software for S7 communication S5-compatible communication (SEND/RECEIVE) and PG/OP communication incl. S7-OPC server for CP 1613 with electronic manual on CD-ROM German/English TF-1613/Windows NT 4.0, 2000 Pro V2.1 Software for TF protocol, S5-compatible communication PG/OP communication for CP 1613 incl. OPC server for S5-compatible communication with electronic manual on CD-ROM German/English PG-1613/Windows NT 4.0, 2000 Pro V2.1 Software for PG/OP communication for CP 1613, with electronic manual on CD-ROM German/English
Order No.
6GK1 161-3AA00
6GK1 716-1CB21-3AA0
6GK1 716-1TB21-3AA0
approx.
6GK1 716-1PB21-3AA0
max. max.
120 120
max. max.
120 120
S7-REDCONNECT/Windows NT 4.0 } V1.3 Software for fail-safe S7 communication via redundant networks for CP 1413, CP 5412 (A2), CP 1613, incl. S7-OPC server with electronic manual on CD-ROM German/English
6GK1 716-0HB13-3AA0
} S7-REDCONNECT/1613 Windows NT 4.0 Upgrade V1.3 Expansion of S7-1613/Windows NT 4.0 to S7-REDCONNECT/Windows NT 4.0 on CD-ROM German/English
Manual: CP 1613 for Industrial Ethernet Hardcopy: contains a description of the interfaces (S7, TF, S5-compatible communication), OPC server, configuring tool for CP 1613 German } English } Electronic Manuals Communications systems, protocols, products on CD-ROM German/English SIMATIC NET Software Update Service for Industrial Ethernet, PROFIBUS, OPC server, including manuals, on CD-ROM, German/English
6GK1 716-0HB13-3AA4
6GK1 704-0AA00-3AA2
Industrial Ethernet
System interfacing for PG/PC
S7-REDCONNECT
Overview
ISO TCP/IP PG/OP S7 C
PC with S7-REDCONNECT and 2 x CP 1613
G_IK10_deI0048s
For connection of PCs for redundant Industrial Ethernet to SIMATIC S7-400H For redundantly structured Industrial Ethernet. Operation is also possible in non-redundant networks.
S5 C
IT
TF
OPC
Industrial Ethernet Industrial Ethernet
Completely integrated in STEP 7 from V5.0. OPC servers are supplied with the communications software
S7-400H
S7-400H
Application
The software package S7-REDCONNECT connects the SIMATIC S7-400H to applications on the PC, e.g. WinCC.
Typically, a redundant Industrial Ethernet is used. The software package can also be used where SIMATIC H systems are operated on nonredundant networks. PC with: up to two CP 1613 and S7-REDCONNECT for connecting the PC to Industrial Ethernet with ISO protocol under Windows NT 4.0 Fault detection, switching over if required, communication monitoring and synchronization are handled in the background invisible to the application.
Design
The following components are necessary for assembling a SIMATIC H system with PC connection
S7-400H with: CP 443-1 for connecting the S7-400H to Industrial Ethernet with ISO protocol STEP 7 from V5.0 upwards for configuring. The application, e.g. Win CC, communicates with the 2 subunits of the S7-400H in the same way as with an S7 CPU.
Application
The highly available S7 communication is fed via a master and a reserve connection concealed for the application which is monitored during operation and switched over in the event of a fault. S7-REDCONNECT contains the functional scope of the S7-1613 software package (S7 communication, S5-compatible communication and PG/OP communication) as well as additional redundant communication via S7 connections. An additional licence for S7-1613 is unnecessary. S5-compatible communication Time synchronization. Continuing to use existing Windows applications Services for monitoring the redundant communication. Diagnostics tool for visualizing the communication status
Functions
User interfaces OPC interface The OPC server contained in the respective software package can be used as a standard programming interface for the protocols S7 communication and S5-compatible communication to connect automation applications to OPC-capable Windows applications (Office, HMI systems etc.).
Programming interface via C library The programming interfaces for the protocols S7 communication, PG/OP communication, S5-compatible communication and TF protocol for existing applications are implemented as a Dynamic Link Library (DLL). The following compilers can therefore be used in conjunction with the SIMATIC NET products: Microsoft Visual C/C++ V6.0 Microsoft Visual Basic V6.0
4/119
Industrial Ethernet
System interfacing for PG/PC
S7-REDCONNECT
Configuration
PC with S7-REDCONNECT and 2 x CP 1613 PC
OSM OSM
OSM OSM
S7-300
OSM OSM
10/100 Mbit/s
Third-party system
100 Mbit/s
OSM OSM
S7-400
OSM OSM OSM OSM
H system
S7-400
S7-400
H system
G_IK10_deI0053s
4
Configuration Designed for Industry
The configuration established for the PCs with STEP 7 from V5.0 is written to files and transferred to the PCs. Provides protection against communication failure in the event of a fault in the double bus or in redundant rings. Simplifies communication of a PC application with the SIMATIC S7-400H system. Safeguards previous investments due to the use of existing applications and the flexible application possibilities. No additional programming required for PC and H systems. Increases availability of the PC application (e.g. PC S7) through redundant communication.
Ordering data
S7-REDCONNECT/Windows NT 4.0 } V1.3 Software for fail-safe S7 communication via redundant networks (Industrial Ethernet, PROFIBUS) under Windows NT 4.0, can be operated with CP 5412 (A2) and CP 1613 including S7-OPC server with electronic manual on CD-ROM German/English
} S7-REDCONNECT/1613/ Windows NT 4.0 Upgrade V1.3 Expansion of S7-1613/Windows NT 4.0 to S7-REDCONNECT/Windows NT 4.0 on CD-ROM German/English
6GK1 716-0HB13-3AA4
Industrial Ethernet
System interfacing for PG/PC
CP 1411 communication processor
Overview
ISO TCP/IP PG/OP S7 C
For connecting PG/PC to Industrial Ethernet Communication services via ISO or TCP/IP transport protocols PG/OP communication S7 communication S5-compatible communication (SEND/RECEIVE)
Designed for use in industrial environments. ISA card Interfaces: AUI, Industrial Twisted Pair, RJ45 (for office applications). Plug&Play OPC servers are supplied with the communication software
S5 C
IT
TF
OPC
Application
The CP 1411 is an Ethernet card which can be operated in any programming device/PC with a free ISA slot. 15-pin Sub-D socket for use in industrial applications (automatic switching between AUI or industrial twisted pair) RJ45 interface for connection in the office environment
The CP 1411 can be operated with all SOFTNET for Industrial Ethernet packages.
Design
With a special controller, the CP 1411 is able to support the plug&play mechanism of the operating system.
There is no need to set jumpers. The configuration is made by software. The settings are resident on the module. Free assignment of the Ethernet address allows the user to make rapid and simple changes for startup or diagnostics. In addition, the protocols for Industrial Ethernet provided by the operating system are also supported. The AUI interface under Windows 2000 Professional is not supported.
Application
The CP 1411 offers the following accesses: Layer 2: Interfacing for PC networks in an industrial environment.
Level 4 and level 7. In conjunction with SOFTNET packages for Industrial Ethernet, the CP 1411 offers low-cost access to Industrial Ethernet, e.g. for SIMATIC S5/S7.
4/121
Industrial Ethernet
System interfacing for PG/PC
CP 1411 communication processor
Designed for Industry Universal connection possibilities (AUI, ITP or RJ45) Optimized for SOFTNET. Ideal for small installations.
Technical specifications
Transmission rate Interfaces Connection to Industrial Ethernet 10 Mbit/s 15-pin Sub-D socket (autom. switching between AUI and Industrial Ethernet pair) RJ45 +5 V DC 5% 12 V DC 5% approx. max. 100 mA 500 mA 0.5 W +5 C to +40 C 40 C to +70 C 95% at +25 C Short AT format 107 15 100 g 1 ISA slot
Ordering data
CP 1411 ISA card for connecting a PG/PC to Industrial Ethernet
Order No.
6GK1 141-1AA00
Connection to 10BaseT Supply voltage Current consumption from 5 V DC from 12 V DC Power loss
Perm. ambient conditions Operating temperature Transportation/storage temperature Relative humidity max. Construction Module format Dimensions (H x D) in mm Weight Space requirements
SOFTNET-S7/Windows 98, NT 4.0, 2000 Pro for Industrial Ethernet V3.3 via ISO or TCP/IP, Software for S5-compatible communication (SEND/RECEIVE) and S7 communication, incl. OPC server, for CP 1411/CP 1511 with electronic manual on CD-ROM German/English Version up to 8 connections (S7) } 6GK1 704-1CW33-3AA0 SOFTNET-PG/Windows 98, } NT 4.0, 2000 Pro for Industrial Ethernet Software V3.3 for PG/OP communication (STEP 5 from V7.1; STEP 7 from V4.02 and K4.02.5), for SIMATIC S5/S7 incl. OPC server, for CP 1411/CP 1511, with electronic manual on CD-ROM German/English SOFTNET Manual for Industrial Ethernet Hardcopy Including: Description of the interfaces (S7, S5-compatible communication), OPC server, configuring tool German } English } SIMATIC NET Software Update Service for Industrial Ethernet, PROFIBUS, OPC server, including manuals on CD-ROM Electronic Manuals Communications systems, protocols, products on CD-ROM German/English 6GK1 704-1PW33-3AA0
approx.
6GK1 975-1AA00-3AA0
Industrial Ethernet
System interfacing for PG/PC
CP 1511 communication processor
Overview
ISO TCP/IP PG/OP S7 C
For connecting programming devices/ notebooks with PCMCIA slot to Industrial Ethernet Communication services via ISO or TCP/IP transport protocols PG/OP communication S7 communication S5-compatible communication (SEND/RECEIVE)
Designed for use in industrial environments. PCMCIA card type II. Interfaces: Industrial Twisted Pair, RJ45 (for office applications). OPC servers are supplied with the communication software
S5 C
IT
TF
OPC
Application
The CP 1511 is an Ethernet card which can be operated in any programming device/PC with a free PCMCIA type II slot.
In conjunction with all SOFTNET packages for Industrial Ethernet (except UNIX), the CP 1511 can be used e.g. in a programming device 720 for remote programming (PG/OP communication). The CP 1511 can be operated in any computer with a slot complying with the PCMCIA 2.0 standard. There are no jumpers on the module, it can be set completely by software. Level 4 and level 7. In conjunction with the SOFTNET packages for Industrial Ethernet, the CP 1511 offers low-cost access to Industrial Ethernet, e.g. to the SIMATIC S5/S7.
Two adapters are supplied. One adapter is designed for connecting to RJ45, another adapter offers an interface for industrial twisted pair.
4
In addition, the protocols for Industrial Ethernet provided by the operating system are also supported. The CP 1511 is not supported under the Windows 2000 Pro operating system.
Design
PCMCIA card type II. 15-pin Sub-D socket for industrial twisted pair The CP 1511 offers the following accesses: Layer 2: Interfacing for PC networks in an industrial environment.
Application
4/123
Industrial Ethernet
System interfacing for PG/PC
CP 1511 communication processor
Configurations
Production Level
PC with CP 1613 and WinCC
Control Room
PG/Notebook with CP 1511
S7-400
S7-400
S7-400
ESM ITP80
ESM
FC Standard Cable
TP Cord 9 / RJ45
Outlet RJ45
G_IK10_deI0068s
Technical specifications
Transmission rate Interfaces Connection to ITP Connection to 10BaseT Connection to PG/PC Supply voltage Current consumption max. 10 Mbit/s 15-pin Sub-D socket RJ45 PCMCIA slot type II +5 V DC, 5% 0.18 A +5 C to +40 C 20 C to +60 C 90% at +25 C PCMCIA type II 85.6 54 5 approx. 30 g 1 PCMCIA slot type II ITP 60 40 18 100 g 50 cm RJ45 40 22 20 40 g 20 cm
Ordering data
} CP 1511 PCMCIA card for the connection of PG/PC to Industrial Ethernet, including 2 adapters for ITP and RJ45
SOFTNET-S7/Windows 98, NT 4.0, 2000 Pro for Industrial Ethernet German/English Version up to 8 connections (S7) SOFTNET-PG/Windows 98, NT 4.0, 2000 Pro for Industrial Ethernet German/English SIMATIC NET Software Update Service for Industrial Ethernet, PROFIBUS, OPC server, including manuals, on CD-ROM, German/English CP 1613 and SOFTNET Manual for Industrial Ethernet Hardcopy German English Electronic Manuals Communications systems, protocols, products on CD-ROM German/English
Perm. ambient conditions Operating temperature Transportation/storage temperature Relative humidity max. Construction of the CP 1511 Module format Dimensions (H W D) in mm Weight Space requirements Construction of adapter Dimensions (H W D) in mm Weight Line length
} }
6GK1 704-0AA00-3AA2
} } }
Industrial Ethernet
System interfacing for PG/PC
SOFTNET for Industrial Ethernet
Overview
ISO TCP/IP PG/OP S7 C
CP 1411 CP 1511 PC/PG SOFTNET for Industrial Ethernet
For connecting programming devices/PCs/ workstations with automation systems. Communication services: PG/OP communication S7 communication S5-compatible communication (SEND/RECEIVE) Can be used in conjunction with CP 1411 (ISA), CP 1511 (PCMCIA). Modem (Remote Access Service RAS)
S5 C
IT
TF
OPC
Industrial Ethernet
S5-115U to -155U with CP 1430 TF S7-400 with CP 443-1
G_IK10_deI0040s
Complete protocol stack as software package. OPC servers are supplied with the communication software SOFTNET is available for the following interfaces: CP 1411 (ISA card) CP 1511 (PCMCIA card). Modem (RAS) architecture depends on the network extension and/or workload of the PC used. User interfaces OPC interface The OPC server contained in the respective software package can be used as a standard programming interface for the protocols S7 communication and S5-compatible communication to connect automation applications to OPC-capable Windows applications (Office, HMI systems etc.). Programming interface via C library The programming interfaces for the protocols S7 communication, PG/OP communication, S5-compatible communication and TF protocol for existing applications are implemented as a Dynamic Link Library (DLL). The following compilers can therefore be used in conjunction with the SIMATIC NET products: Microsoft Visual C/C++ V6.0 Microsoft Visual Basic V6.0
Application
With SOFTNET for Industrial Ethernet, programming devices/PCs/workstations can be connected to PLCs, e.g. SIMATIC S7, via Industrial Ethernet. The following application interfaces are available: With SOFTNET, the complete protocol stack is handled by the PC. Software for PG/OP communication This software allows programming of the SIMATIC S5 and S7 controllers via Industrial Ethernet in conjunction with STEP 5/STEP 7. Software for S7 communication SIMATIC S7 system components use S7 communication to communicate with each other. To allow programming device/PC user programs to have access to the SIMATIC S7/M7 system components, the S7 programming interface was developed. The S7 communications can optionally be based on the ISO protocol or the TCP/IP protocol. The interface is supplied as a C library or DLL.
PG/OP communication for SIMATIC S7 S5-compatible communication (SEND/RECEIVE) for communication with SIMATIC S7 S7 communication Unlike the 1613 products, the performance capability of the SOFTNET packages with this S7 communication offers the following services: Administrative services S7 connection management services Variables services VFD (virtual field device) services Trace and Mini database. S5-compatible communication (SEND/RECEIVE) This layer 4 based interface (ISO transport or TCP/IP with RFC 1006) is used for communication between PG/PC and SIMATIC S5 PG/PC and SIMATIC S7 PG/PC and PG/PC. S5-compatible communication (SEND/RECEIVE) provides the following services: Management services. Link connection service. Data transfer services
Application
Functions
4/125
Industrial Ethernet
System interfacing for PG/PC
SOFTNET for Industrial Ethernet
Configuration For the relevant packages the necessary configuring tools are contained in the scope of supply. Communication with SIMATIC via standard Ethernet cards (NE 2000-compatible). Can be used in notebooks with PCMCIA slot. Optimized for small installations.
Technical specifications
Performance data S7 and PG/OP communication SOFTNET-S7: Number of operable connections
Ordering data
Order No.
max.
SOFTNET-S7/Windows 98, NT 4.0, 2000 Pro for Industrial Ethernet V3.3 Software for S5-compatible communication (SEND/RECEIVE) and S7 communication, incl. S7-OPC server, for CP 1411/CP 1511 with electronic manual on CD-ROM German/English Version up to 8 connections (S7) } 6GK1 704-1CW33-3AA0 SOFTNET-PG/Windows 98, } NT 4.0, 2000 Pro for Industrial Ethernet Software V3.3 for PG/OP communication (STEP 5 from V7.1; STEP 7 from V4.02 and K4.02.5), for SIMATIC S5/S7, for CP 1411/CP 1511, with electronic manual on CD-ROM German/English CP 1613 and SOFTNET Manual for Industrial Ethernet Hardcopy Including: Description of the interfaces (S7, S5-compatible communication), OPC server, configuring aid German } English } Electronic Manuals Communications systems, protocols, products on CD-ROM German/English SIMATIC NET Software Update Service for Industrial Ethernet, PROFIBUS, OPC server, including manuals on CD-ROM 6GK1 704-1PW33-3AA0
6GK1 704-0AA00-3AA2
CP 5614 (PCI)
PC card with its own microprocessor Recommended solution for: } PC-based control systems (Soft Control, PLC, Numeric Control, Robot Control) } Process control systems } Human Machine Interface (HMI) } PROFIBUS systems with a large quantity framework (more than 8 stations) } Multi-protocol operation } Use of several CPs in one computer } Versions with Fiber Optic interface (FO)
You will find software for the PC products under Windows on the SIMATIC NET/Windows-CD including the appropriate manuals in pdf format and other detailed information on SIMATIC NET products and communication. The necessary configuration tools are contained in all software packages.
CP 5614 FO (PCI)
CP 5511 (PCMCIA)
CP 5611 (PCI)
PC card without its own microprocessor Recommended solution for: } Configuration tools (e.g. STEP 7) } PROFIBUS-DP diagnostics station (e.g. with COM PROFIBUS or as a DP master class 2) } PROFIBUS-DP slave connection } PROFIBUS systems with up to 8 stations } Monoprotocol mode
Siemens IK PI 2001
3/333
Performance
3
CPU loading and access time A comparison of event access (through Interrupt) and polling access shows that the CPU loading in CP 5613 can be reduced considerably using the event/filter mechanism; at the same data throughput.
CP 5613 1) with CP 5412 (A2) with CP 5X11 with DP-5613/Win NT DP-5412/Win NT SOFTNET-DP
CPU load
Note: The CP 5613 is the successor type to CP 5412 (A2) 1) for credit = 1; PDU size 480 byte 2) for credit = 1
3/334
Siemens IK PI 2001
G_IK10_deP0035s
OPC servers are supplied with the communication software Standard, open, manufacturer-independent interface Interfacing of OPC-capable Windows applications to S7 communication and S5-compatible communication (SEND/RECEIVE). Builds upon software programming interfaces. Efficient data exchange for Windows NT 4.0 and Windows 2000 Pro OPC scout with browser function as OPC client and OCX data control
FMS-OPC-Server
DP-OPC-Server
S7-OPC-Server
S7-OPC-Server
FMS protocol
DP protocol
S7 communic.
ET 200X
G_IK10_deP0040s
SIMATIC S5
PROFIBUS
Ind. Ethernet
S7-PC
Application
Under Windows NT, OPC (OLE for Process Control) can be used as an extension to the communications interfaces COM (Component Object Model) and DCOM (Distributed COM) for the user software. The basic principle of OPC is that OPC client applications can communicate with the OPC server through a standard / open and thus manufacturer-independent interface. Connection to OPC-compatible Windows applications already on the market (Office 97 or HMI systems) is possible.
The following OPC servers are available: PROFIBUS: DP-OPC server for PROFIBUS-DP FMS-OPC server for PROFIBUS-FMS S7-OPC servers for S7 communication, alarms and events as well as S5compatible communication (SEND/RECEIVE) The OPC servers have: Standardized access to SIMATIC S7 and SIMATIC S5 for OPC-compatible applications under Windows NT Consistency between automation products from different manufacturers
The same simple-to-use user interface for different components. Accessibility from every computer in the LAN/WAN High-performance data access through the Custom Interface (C++) Easy to use through the Automation Interface (VB) or OCX data control, which is supplied Grouping of variables (items), whereby a large number of data can be processed in a short time
Functions
Open standardization of addressing using logical names for objects of an automation component or system. Support of symbols from STEP 7
Efficient data exchange from a process component to a further processing application Simultaneous use of several servers by one client application
Several clients can run on one OPC server at the same time Server-specific configuration support
Siemens IK PI 2001
3/335
OCX data control for direct integration in Windows applications that support COM/DCOM
Application X
Application Y
3
Fig. 3/112 Comparison of conventional client/server architecture with an OPC architecture
Configuration
The communications parameters can be completely configured using the tools in the software which is already installed.
The following demo programs are supplied as standard: For custom interface in C++ For Automation Interface with Visual Basic
Other compilers can be implemented through the OPC server, however, the compiler must support the COM interface (Microsoft Component Object Model)
Simple use of different networks and protocols through standard interface. Reduced training and learning requirements.
Easy integration in the system environment and office applications through C++ and Visual Basic interface Short programming times for applications.
Easy to handle and costeffective because the OPC servers are supplied with the communication software
3/336
Siemens IK PI 2001
G_IK10_deP0041s
Server A
Server B
Server C
FMS-OPC Server
S7-OPC Server
XY-OPC Server
DP-OPC Server
Product versions
Product DP-5613 S7-5613 FMS-5613 SOFTNET-S7 for PROFIBUS SOFTNET-DP SOFTNET-DP slave CP 5613/5614 and CP 5613 FO/5614 FO with DP-Base software contains OPC servers for: PROFIBUS-DP S7 communication FMS communication S7 communication PROFIBUS-DP PROFIBUS-DP slave S5 compatible communication (FDL) PROFIBUS-DP (master) Access to DP slave of the CP 5614
Open and standardized Can be used with different manufacturers systems Variable (item) groups One set of variables, enabling processing of large data volumes in a short time Custom Interface (C++); OPC is therefore powerful Automation Interface (VB, Excel, Access, Delphi, etc.); therefore easy to use Graphics with OCX; allowing configuration instead of programming DP protocol S7 communication FMS protocol S5-compatible communication (SEND/RECEIVE) Windows NT 4.0, 2000 is automatically available for all applications after installation
Access to
Interfaces
Protocols
Availability
Siemens IK PI 2001
3/337
Application
Advanced PC Configuration represents a new, simple, consistent and cost-effective startup and diagnostics of a PC station. The Startup Wizard, Configuration Console and NCM PC mark the launch of a whole new world of tools.
The Startup Wizard guides the user through all the steps necessary to achieve a ready-to-run PC station The Configuration Console is the central tool for configuration settings and diagnostics
NCM PC V5.1+SP2 offers a new configuring tool for STEP 7-compatible PC configuration
Functions
Startup Wizard Simple and consistent startup of all modules and applications supported by Advanced PC Configuration. A wizard that takes the user step-by-step through the installation and configuration of the PC station.
Configuration Console The Configuration Console is a snap-in embedded in the Microsoft Management Console that offers a range of options for the configuration and diagnostics of PC hardware components and PC applications.
Settings on the OPC servers delivered with the communications software are also executed through the Configuration Console.
3/338
Siemens IK PI 2001
http://www.siemens.de/ simatic-net/ik-info
3
Engineering Station PG/PC with STEP 7 or NCM PC
Advanced PC Configuration
S7-400
G_IK10_deP0154s
Siemens IK PI 2001
3/339
Ordering data
Advanced PC Configuration
Order No. Included in delivery are the following products: S7-5613 DP-5613 FMS-5613 SOFTNET-DP slave for PROFIBUS SOFTNET-DP for PROFIBUS SOFTNET-S7 for PROFIBUS SIMATIC NET CD 07/2001 Upgrade
CP 5511, CP 5611, CP 5613, CP 5613 FO, CP 5614, CP 5614 FO CP 5611 compatible PROFIBUS interfaces of PCs/PGs S5-compatible communication S7 communication DP FMS Windows NT 4.0 SP 6a Windows 2000 +SP1 for Professional and servers
Protocols
Operating systems
3/340
Siemens IK PI 2001
PCI card with microprocessor for system interfacing for PCs and SIMATIC programming devices/PC to PROFIBUS up to 12 Mbit/s Communication services: PROFIBUS-DP master according to IEC 61158/ EN 50170 PG/OP communication with STEP 5 and STEP 7 S7 communication S5-compatible communication (SEND/RECEIVE) on the basis of the FDL interface PROFIBUS-FMS according to IEC 61158/EN 50 170 The CP 5613 enables connection to PROFIBUS for SIMATIC PG/PC and PCs with PCI slot under Windows NT 4.0 and Windows 2000. Short PCI card 9-pin Sub-D socket for connecting to PROFIBUS Diagnostic LEDs. Parallel operation of max. 4 CPs 1) The module is installed using PCI standard mechanisms (plug & play).
Extensive diagnostic facilities for installation, commissioning and operation of the module High performance through direct dual port RAMaccess Event and filter mechanism for relieving the host CPU. OPC servers are supplied with the communication software
S5 C
FMS
OPC
3
It is connected to the optical PROFIBUS with integrated interface and OBT through: Bus cable with 2 bus connectors or 830-1T PROFIBUS connecting cable to an optical bus terminal (OBT) for PROFIBUS-DP. Direct connection to the optical PROFIBUS with integrated interface through CP 5613 FO.
Application
The CP 5613 provides high performance support for control tasks on the PC (e.g. PCbased control, numeric control, robot control). It is connected to the electrical PROFIBUS through Bus connector and PROFIBUS bus cable or Bus terminal (e.g. 12M bus terminal) and PROFIBUS bus cable. It is connected to the optical PROFIBUS through: Bus cable with 2 bus connectors or 830-1T PROFIBUS connecting cable to an OLM. Event/filter mechanism The user receives up-to-date data through two access mechanisms: Cyclic polling of the DP slaves (higher load on host CPU) Signaling through new kind of event/filter mode in the event of changes in the input data of a slave (minimum load on host CPU) Both alternatives can be combined. Optimum utilization of the PC is therefore possible for the relevant application.
Design
Functions
PROFIBUS-DP Access to process data with DP-Base The CP 5613 is operated as a PROFIBUS-DP master module which holds the process image (input/output and diagnostic data) in the dual port RAM (memory area on the CP). The high-performance data exchange with the PROFIBUS slaves is handled independently by the CP 5613 hardware. The user has direct access to the dual port RAM. The process data of the slaves are always consistent, i.e. the user gets the data from one and the same DP cycle. Parallel operation of DP-Base and DP 5613 software is not possible.
The new event/filter mechanism also can be used for Signaling by interrupt for diagnostic messages from slaves In equidistant mode signaling by interrupt: Start DP cycle End of cyclic data exchange with the DP slaves (from hardware version 3, available soon) Equidistant operation adjustable with STEP 7 V5.1 or higher or NCM PC V5.1+SP2.
Siemens IK PI 2001
3/341
DP master class 2 In addition to DP master class 1 services, the CP 5613 also offers DP master class 2 services in connection with the DP programming interface according to IEC 61158/ EN 50170. Devices of this type (programming, configuration or operating devices) are used for commissioning, configuring the DP system or system operation in normal operation (diagnostics). The DP programming interface provides the following services: Master diagnostics Slave diagnostics Read inputs/outputs of a slave Reading configuration data and Changing the slave address. The extended DP functions also include non-cyclic access to the parameters and measured values of a slave (e.g. field devices of the process automation, intelligent HMI devices. This type of slave must be supplied with extensive parameter data during startup and normal operation (DS_READ, DS_WRITE, DS_DATA_TRANSPORT). Software for PG/OP communication This software enables programming of the SIMATIC S5/S7 controllers through PROFIBUS in connection with STEP 5/STEP 7. The PG/OP communication for the CP 5613 is already available after installing the CP 5613 (DP-Base). No additional software package is needed. S5-compatible communication (SEND/RECEIVE based on the FDL interface) SEND/RECEIVE (FDL interface) is already available after installation of the CP 5613 (DP-Base) and offers data exchange services for diagnostics and management. No additional software package is needed.
3/342
Siemens IK PI 2001
http://www.siemens.de/ simatic-net/dk5613
Configuration
Configuration of S7 communication protocols, S5-compatible communication, DP protocol (DP/DPV1/ DPV2) and FMS protocol is executed in STEP 7/NCM PC, V5.1+SP2 or higher.
The configuring tool NCM PC is included in delivery of the PROFIBUS software package.
Diagnosis
Extensive diagnostic tools are available (for installation, commissioning and operation) for the module itself and for the PROFIBUS network.
Therefore a PROFIBUS network can be started up quickly and easily with a CP 5613.
Siemens IK PI 2001
3/343
Fastest possible access to process data through dual port RAM Short response time with FastLogic Process-consistent data from a DP cycle
Higher computing performance in the PC by relieving the host CPU. Fast commissioning through Plug&Play and diagnostic tools Implementation for motion control applications possible through support of the equidistant mode
Easy portability to other operating systems through a dual port RAM interface Can also be used in high temperature industrial environments.
Technical specifications
Baud rates Interfaces Connection to PROFIBUS 9.6 kbit/s to 12 Mbit/s 9-pin Sub-D socket 5 V DC 5% 1.3 A 6.5 W
Ordering data
Supply voltage (from PCI) Power consumption from 5 V Power loss Perm. ambient conditions Operating temperature Without fan With fan (air current 0.5 m/s) Transport/storage temperature Relative humidity Design Module format Dimensions (W H) in mm Weight Space required Performance data Single protocol mode No. of connectable DP slaves No. of parallel FDL tasks to be processed No. of PG/OP and S7 connections No. of FMS connections
} DP-5613/Windows V6.0 Software for DP protocol incl. PG/OP communication, FDL, DP-OPC server; NCM PC under Windows NT 4.0 WS, server; Windows 2000 Pro, server; for CP 5613/ CP 5614/CP 5613 FO/CP 5614 FO; with electronic manual; on CD-ROM, in German/English } S7-5613/Windows V6.0 Software for S7 communication incl. PG/OP communication, FDL, S7-OPC server; NCM PC under Windows NT 4.0 WS, server; Windows 2000 Pro, server; for CP 5613/ CP 5614/CP 5613 FO/CP 5614 FO; with electronic manual; on CD-ROM, in German/English } FMS-5613/Windows V6.0 Software for FMS protocol incl. PG/OP communication, FDL, FMS-OPC server; NCM PC under Windows NT 4.0 WS, server; Windows 2000 Pro, server; for CP 5613/ CP 5614/CP 5613 FO/CP 5614 FO; with electronic manual; on CD-ROM, in German/English
Manual CP 5613/CP 5614 and SOFTNET for PROFIBUS Paper version Including: Description of the interfaces (FMS, DP, S7, FDL), OPC server, configuration tools German English PROFIBUS FastConnect RS 485 bus connector Plug 180 With 180 cable outlet
max.
+5 C to +40 C +5 C to +60 C 40 C to +70 C 95% at +25 C PCI card 107 168 250 g 1 PCI slot
6GK1 713-5CB60-3AA0
approx.
6GK1 713-5FB60-3AA0
122 120 50 1) 40 2)
Ordering data
CP 5613 communications processor PCI card for connection to PROFIBUS incl. Windows NT 4.0 WS, server, Windows 2000 Pro, server driver, DPRAM Interface for DP master incl. PG and FDL, configuration software; with electronic manual; on CD-ROM
Order No.
6GK1 561-3AA00
} } }
} PROFIBUS 12M bus terminal Bus terminal for connecting PROFIBUS stations up to 12 Mbit/s with connecting cable
SIMATIC NET Software Update Service For Industrial Ethernet, PROFIBUS, OPC server, including manuals, on CD-ROM, German/English SIMATIC NET Manual Collection Electronic manuals for communication systems, protocols, products on CD-ROM German/English
6GK1 500-0AA10
Development kit DK-5613 Software development kit for CP 5613/CP 5614/CP 5613 FO/ CP 5614 FO for integration in any operating system environments on systems with PCI slot Download from Internet at: http://www.siemens.de/ simatic-net/dk5613
6GK1 704-0AA00-3AA2
6GK1 975-1AA00-3AA0
3/344
Siemens IK PI 2001
PCI card with microprocessor for system interfacing for PCs and SIMATIC PGs/PC to the optical PROFIBUS with integrated interface up to 12 Mbit/s Integrated FOC interface for direct FO connection Communication services: PROFIBUS-DP master according to IEC 61158/ EN 50170 PG/OP communication with STEP 5 and STEP 7. S7 communication S5-compatible communication (SEND/RECEIVE) on the basis of the FDL interface PROFIBUS-FMS according to IEC 61158/ EN 50170
Extensive diagnostic facilities for installation, commissioning and operation of the module High performance through direct dual port RAM access Event and filter mechanism for relieving the host CPU. Multiple protocol operation and parallel operation of up to 4 CPs OPC servers are supplied with the communication software
S5 C
FMS
OPC
Application
The CP 5613 FO enables connection to the optical PROFIBUS with integrated interface for SIMATIC PG/PC and PCs with PCI slot under Windows NT 4.0 and Windows 2000.
The CP 5613 FO provides high performance support for control tasks on the PC (e.g. PC- based control, numeric control, robot control).
Design
Short PCI card 2 duplex sockets for connection of plastic and PCF FOCs with 2 simplex plugs each to the optical PROFIBUS Connection for external power supply. This means data transmission on the optical line is not interrupted when the PC is switched off.
Diagnostic LEDs. Parallel operation of up to 4 CPs. The module is installed using standard PCI mechanisms (Plug & Play).
It is connected to the optical PROFIBUS with integrated interface through: Plastic and PCF FOCs with simplex plugs. It is connected to the electrical PROFIBUS through Plastic and PCF fiber-optic cable with simplex plugs to an OBT.
Functions
PROFIBUS-DP Access to process data with DP-Base The CP 5613 FO is operated as a PROFIBUS-DP master module which holds the process image (input/output and diagnostic data) in the dual port RAM (memory area on the CP). The high-performance data exchange with the PROFIBUS slaves is handled independently by the CP 5613 FO hardware. The user has direct access to the dual port RAM. The process data of the slaves are always consistent, i.e. the user gets the data from one and the same DP cycle. Parallel operation of DP-Base and DP 5613 software is not possible.
Event/filter mechanism The user receives up-to-date data through two access mechanisms: Cyclic polling of the DP slaves (higher load on host CPU) Signaling by new kind of event/filter mode in the event of changes in the input data of a slave (minimum load on host CPU) Both alternatives can be combined. Optimum utilization of the PC is therefore possible for the relevant application.
The new event/filter mechanism can also be used for: Signaling by interrupt for diagnostic messages from slaves In equidistant mode signaling by interrupt: Start DP cycle End of cyclic data exchange with the DP slaves (from hardware version 3, available soon) Equidistant operation adjustable with STEP 7 V5.1 or higher or NCM PC V5. 1+SP2.
Siemens IK PI 2001
3/345
DP master class 2 In addition to DP master class 1 services, the CP 5613 FO also offers DP master class 2 services in connection with the DP programming interface according to IEC 61 158/EN 50170. Devices of this type (programming, configuration or operating devices) are used for commissioning, configuring the DP system or system operation in normal operation (diagnostics). The DP programming interface provides the following services: Master diagnostics Slave diagnostics Read inputs/outputs of a slave Reading configuration data and Changing the slave address. The extended DP functions also include non-cyclic access to the parameters and measured values of a slave (e.g. field devices of the process automation, intelligent HMI devices. This type of slave must be supplied with extensive parameter data during startup and normal operation (DS_READ, DS_WRITE, DS_DATA_TRANSPORT). Software for PG/OP communication This software enables programming of the SIMATIC S5/S7 controllers through PROFIBUS in connection with STEP 5/STEP 7. The PG/OP communication for the CP 5613 FO is already available after installing the CP 5613 FO (DP-Base). No additional software package is needed. S5-compatible communication (SEND/RECEIVE based on the FDL interface) SEND/RECEIVE (FDL interface) is already available after installation of the CP 5613 FO (DP-Base) and offers data exchange services for diagnostics and management. No additional software package is needed.
3/346
Siemens IK PI 2001
http://www.siemens.de/ simatic-net/dk5613
Configuration
Configuration of S7 communication protocols, S5-compatible communication, DP protocol (DP/DPV1/ DPV2) and FMS protocol is executed in STEP 7/NCM PC, V5.1+SP2 or higher.
The configuring tool NCM PC is included in delivery of the PROFIBUS software package.
Diagnosis
Extensive diagnostic tools are available (for installation, commissioning and operation) for the module itself and for the PROFIBUS network.
Therefore a PROFIBUS network can be started up quickly and easily with a CP 5613 FO.
Fastest possible access to process data through dual port RAM Short response time with FastLogic Process-consistent data from a DP cycle Direct connection to the optical PROFIBUS through integrated FOC interface
Higher computing performance in the PC by relieving the host CPU. Fast commissioning through Plug&Play and diagnostic tools Implementation for motion control applications possible through support of the equidistant mode
Easy portability to other operating systems through a dual port RAM interface Can also be used in high temperature industrial environments.
Siemens IK PI 2001
3/347
Ordering data
CP 5613 FO communications processor PCI card for connection to PROFIBUS-DP incl. Windows NT 4.0 WS, server, Windows 2000 Pro, server driver, DPRAM Interface for DP master incl. PG and FDL, configuration software; with electronic manual; on CD-ROM Development kit 1) DK-5613 Software development kit for CP 5613/CP 5614 for integration in any operating system environments on systems with PCI slot DP-5613/Windows V6.0 } Software for DP protocol incl. PG/OP communication, FDL, DP-OPC server; NCM PC under Windows NT 4.0 WS, server; Windows 2000 Pro, server; for CP 5613/ CP 5614/CP 5613 FO/CP 5614 FO; with electronic manual; on CD-ROM, in German/English
Order No.
6GK1 561-3FA00
6GK1 713-5DB60-3AA0
max.
+5 C to +40 C +5 C to +60 C 40 C to +70 C 95% at +25 C PCI card 107 168 250 g 1 PCI slot
approx.
} S7-5613/Windows V6.0 Software for S7 communication incl. PG/OP communication, FDL, S7-OPC server; NCM PC under Windows NT 4.0 WS, server; Windows 2000 Pro, server; for CP 5613/ CP 5614/CP 5613 FO/CP 5614 FO; with electronic manual; on CD-ROM, in German/English } FMS-5613/Windows V6.0 Software for FMS protocol incl. PG/OP communication, FDL, FMS-OPC server; NCM PC under Windows NT 4.0 WS, server; Windows 2000 Pro, server; for CP 5613/ CP 5614/CP 5613 FO/CP 5614 FO; with electronic manual; on CD-ROM, in German/English
Manual CP 5613/CP 5614 and SOFTNET for PROFIBUS Paper version Including: Description of the interfaces (FMS, DP, S7, FDL), OPC server, configuration tools German English SIMATIC NET Software Update Service For Industrial Ethernet, PROFIBUS, OPC server, including manuals, on CD-ROM, German/English SIMATIC NET Manual Collection Electronic manuals for communication systems, protocols, products on CD-ROM German/English 1) Download from the Internet at
6GK1 713-5CB60-3AA0
6GK1 713-5FB60-3AA0
} } }
6GK1 975-1AA00-3AA0
http://www.siemens.de/simatic-net/dk5613
3/348
Siemens IK PI 2001
PCI card with microprocessor for system interfacing for PCs and SIMATIC programming devices/IPC to PROFIBUS up to 12 Mbit/s Communication services: PROFIBUS-DP master interface according to IEC 61158/EN 50 170 on a PCI card PROFIBUS-DP slave interface according to IEC 61158/EN 50 170 on a PCI card PG/OP communication with STEP 5 and STEP 7. S7 communication
S5-compatible communication (SEND/RECEIVE) on the basis of the FDL interface PROFIBUS-FMS according to IEC 61158/ EN 50170 High performance through direct dual port RAMaccess Event and filter mechanism for relieving the host CPU. OPC servers are supplied with the communication software
S5 C
FMS
OPC
Application
The CP 5614 supports connection to PROFIBUS for SIMATIC PG/IPC and PCs with PCI slot under Windows NT 4.0 and Windows 2000, whereby it can operate both as DP master and as DP slave independently of one another. Short PCI card 2 9-pin Sub-D sockets for connecting to PROFIBUS Diagnostic LEDs. Parallel operation of up to 4 CPs. The module is installed using standard PCI mechanisms (plug & play).
This means that two different PROFIBUS networks can be connected to a PC in a hierarchic structure using one PROFIBUS card and data can be exchanged between the networks.
The CP 5614 provides high performance support for control tasks on the PC (e.g. PC based control, numeric control, robot control).
Design
It is connected to the electrical PROFIBUS through Bus connector and PROFIBUS bus cable or Bus terminal (e.g. 12M bus terminal) and PROFIBUS bus cable. It is connected to the optical PROFIBUS through Bus cable with 2 bus connectors or 830-1T PROFIBUS connecting cable to an OLM. Parallel operation of DP 5613 (DP master) and DP-Base (DP master, DP slave) is not possible. Event/filter mechanism The user receives up-to-date data through two access mechanisms: Cyclic polling of the DP slaves (higher load on host CPU) Signaling by new kind of event/filter mode in the event of changes in the input data of a slave (minimum load on host CPU)
It is connected to the optical PROFIBUS with integrated interface and OBT through: Bus cable with 2 bus connectors or 830-1T PROFIBUS connecting cable to an optical bus terminal (OBT) for PROFIBUS. Direct connection to the optical PROFIBUS with integrated interface through CP 5614 FO.
Functions
PROFIBUS-DP Access to process data The CP 5614 is operated as a PROFIBUS-DP master and DP slave module which holds the process image (input/output and diagnostic data) in the dual port RAM. The high-performance data exchange with the PROFIBUS slaves is handled independently by the CP 5614 FO hardware. The user has direct access to the dual port RAM. The process data of the slaves are always consistent, i.e. the user gets the data from one and the same DP cycle.
Both alternatives can be combined. Optimum utilization of the PC is therefore possible for the relevant application. The new event/filter mechanism can also be used for: Signaling by interrupt for diagnostic messages from slaves In equidistant mode signaling by interrupt: Start DP cycle End of cyclic data exchange with the DP slaves (from hardware version 3, available soon) Equidistant operation adjustable with STEP 7 V5.1 or higher or NCM PC V5. 1+SP2.
Siemens IK PI 2001
3/349
DP master class 2 In addition to DP master class 1 services, the CP 5614 also offers DP master class 2 services in connection with the DP programming interface according to IEC 61158/ EN 50170. Devices of this type (programming, configuration or operating devices) are used for commissioning, configuring the DP system or system operation in normal operation (diagnostics) The DP programming interface provides the following services: Master diagnostics Slave diagnostics Read inputs/outputs of a slave Reading configuration data and Changing the slave address. The extended DP functions also include non-cyclic access to the parameters and measured values of a slave (e.g. field devices of the process automation, intelligent HMI devices). This type of slave has to be supplied with extensive parameter data during startup and normal operation. (DS_READ, DS_WRITE, DS_DATA_TRANSPORT).
3/350
Siemens IK PI 2001
http://www.siemens.de/ simatic-net/dk5613
Siemens IK PI 2001
3/351
Configuration of S7 communication protocols, S5-compatible communication, DP protocol (DP/DPV1/ DPV2) and FMS protocol is executed in STEP 7/NCM PC, V5.1+SP2 or higher.
The configuring tool NCM PC is included in delivery of the PROFIBUS software package.
Diagnosis
Extensive diagnostic tools are available (for installation, commissioning and operation) for the module itself and for the PROFIBUS network.
Therefore a PROFIBUS network can be started up quickly and easily with a CP 5614.
Only 1 slot is required for a master and slave Fastest possible access to process data through dual port RAM Short response time with FastLogic Process-consistent data from a DP cycle
Higher computing performance in the PC by relieving the host CPU Fast commissioning through Plug&Play and diagnostic tools Implementation for motion control applications through support of the equidistant mode
Easy portability to other operating systems through a dual port RAM interface Can also be used in high temperature industrial environments.
PROFIBUS
Transfer mechanism DP slave RS 485 DP master CP 5614 Distributed I/O
PROFIBUS
SIMATIC ET 200M
SIMATIC ET 200S
3/352
Siemens IK PI 2001
G_IK10_deP0110s
Ordering data
} DP-5613/Windows V6.0 Software for DP protocol incl. PG/OP communication, FDL, DP-OPC server; NCM PC under Windows NT 4.0 WS, server; Windows 2000 Pro, server; for CP 5613/ CP 5614/CP 5613 FO/CP 5614 FO; with electronic manual; on CD-ROM, in German/English } S7-5613/Windows V6.0 Software for S7 communication incl. PG/OP communication, FDL, S7-OPC server; NCM PC under Windows NT 4.0 WS, server; Windows 2000 Pro, server; for CP 5613/ CP 5614/CP 5613 FO/CP 5614 FO; with electronic manual; on CD-ROM, in German/English } FMS-5613/Windows V6.0 Software for FMS protocol incl. PG/OP communication, FDL, FMS-OPC server; NCM PC under Windows NT 4.0 WS, server; Windows 2000 Pro, server; for CP 5613/ CP 5614/CP 5613 FO/CP 5614 FO; with electronic manual; on CD-ROM, in German/English
Manual CP 5613/CP 5614 and SOFTNET for PROFIBUS Paper version Including: Description of the interfaces (FMS, DP, S7, FDL), OPC server, configuration tools German English PROFIBUS FastConnect RS 485 bus connector Plug 180 With 180 cable outlet
6GK1 713-5CB60-3AA0
max.
+5 C to +40 C +5 C to +60 C 40 C to +70 C 95% at +25 C PCI card 107 168 300 g 1 PCI slot
approx.
6GK1 713-5FB60-3AA0
max.
122
120 50 1) 40 2)
} } }
Ordering data
CP 5614 communications processor PCI card with master and slave connection to PROFIBUS, incl. Windows NT 4.0 WS, server, Windows 2000 Pro, server driver, DPRAM Interface for DP master and slave, PG and FDL, configuration software with electronic manual on CD-ROM
Order No.
6GK1 561-4AA00
} PROFIBUS 12M bus terminal Bus terminal for connecting PROFIBUS stations up to 12 Mbit/s with connecting cable
SIMATIC NET Software Update Service for Industrial Ethernet, PROFIBUS, OPC server, including manuals, on CD-ROM, in German/English SIMATIC NET Manual Collection Electronic manuals for communication systems, protocols, products on CD-ROM German/English
6GK1 500-0AA10
6GK1 704-0AA00-3AA2
Development kit 1) DK-5613 Software development kit for CP 5613/CP 5614 for integration in any operating system environments on systems with PCI slot
6GK1 975-1AA00-3AA0
http://www.siemens.de/simatic-net/dk5613
Siemens IK PI 2001
3/353
PCI card with microprocessor for system interfacing for PCs and SIMATIC PG/PC to the optical PROFIBUS with integrated interface up to 12 Mbit/s Integrated FOC interface for direct FO connection Communication services: PROFIBUS-DP master interface according to IEC 61 158/EN 50 170 on a PCI card PROFIBUS-DP slave interface according to IEC 61 158/EN 50 170 on a PCI card PG/OP communication with STEP 5 and STEP 7.
S5 C
FMS
OPC
S7 communication S5-compatible communication (SEND/RECEIVE) on the basis of the FDL interface PROFIBUS-FMS according to IEC 61 158/ EN 50170 High performance through direct dual port RAM access Event and filter mechanism for relieving the host CPU. Multiple protocol operation and parallel operation of up to 4 CPs OPC servers are supplied with the communication software a PROFIBUS card and can exchange data. The CP 5614 FO provides high performance support for control tasks on the PC (e.g. PC-based control, numeric control, robot control). It is connected to the optical PROFIBUS with integrated interface and OBT through: Plastic and PCF FOCs with simplex plugs. It is connected to the electrical PROFIBUS through Plastic and PCF fiber-optic cable with simplex plugs to an OBT.
3
Application The CP 5614 FO enables connection to PROFIBUS-DP for SIMATIC PG/PC and AT-compatible PCs with PCI slot under Windows NT 4.0 and Windows 2000. Design
It can be either a DP master or a DP slave independently of each other. In this way two different PROFIBUS networks can be connected in a hierarchical structure to one PC with
Short PCI card 2 duplex sockets for connection of plastic and PCF FOCs with 2 simplex plugs each to the optical PROFIBUS 9-pin Sub-D socket for connecting to PROFIBUS Connection for external power supply. This means data transmission on the optical line is not interrupted when the PC is switched off.
Diagnostic LEDs. Parallel operation of up to 4 CPs. The software can switch assignment of master and slave to the optical and electrical interface. The module is installed using standard PCI mechanisms (plug & play).
Functions
PROFIBUS-DP Access to process data The CP 5614 is operated as a PROFIBUS-DP master and slave module which holds the process image (input/output and diagnostic data) in the dual port RAM. The high-performance data exchange with the PROFIBUS slaves is handled independently by the CP 5614 FO hardware. The user has direct access to the dual port RAM. The process data of the slaves are always consistent, i.e. the user gets the data from one and the same DP cycle. Parallel operation of DP 5613 (DP master) and DP-Base (DP master, DP slave) is not possible.
Event/filter mechanism The user receives up-to-date data through two access mechanisms: Cyclic polling of the DP slaves (higher load on host CPU) Signaling by new kind of event/filter mode in the event of changes in the input data of a slave (minimum load on host CPU) Both alternatives can be combined. Optimum utilization of the PC is therefore possible for the relevant application. The new event/filter mechanism can also be used for:
Signaling by interrupt for diagnostic messages from slaves In equidistant mode signaling by interrupt: Start DP cycle End of cyclic data exchange with the DP slaves (from hardware version 3, available soon) Equidistant operation adjustable with STEP 7 V5.1 or higher or NCM PC V5. 1+SP2.
3/354
Siemens IK PI 2001
DP master class 2 In addition to DP master class 1 services, the CP 5614 FO also offers DP master class 2 services in connection with the DP programming interface according to IEC 61158/ EN 50170. Devices of this type (programming, configuration or operating devices) are used for commissioning, configuring the DP system or system operation in normal operation (diagnostics). The DP programming interface provides the following services: Master diagnostics Slave diagnostics Read inputs/outputs of a slave Reading configuration data and Changing the slave address. The extended DP functions also include non-cyclic access to the parameters and measured values of a slave (e.g. field devices of the process automation, intelligent HMI devices. This type of slave has to be supplied with extensive parameter data during startup and normal operation. (DS_READ, DS_WRITE, DS_DATA_TRANSPORT).
Siemens IK PI 2001
3/355
http://www.siemens.de/ simatic-net/dk5613
3/356
Siemens IK PI 2001
Configuration of S7 communication protocols, S5-compatible communication, DP protocol (DP/DPV1/ DPV2) and FMS protocol is executed in STEP 7/NCM PC, V5.1+SP2 or higher.
The configuring tool NCM PC is included in delivery of the PROFIBUS software package.
Diagnosis
Extensive diagnostic tools are available (for installation, commissioning and operation) for the module itself and for the PROFIBUS network.
Therefore a PROFIBUS network can be started up quickly and easily with a CP 5614 .
Only 1 slot is required for a master and slave. Direct connection to the optical PROFIBUS through integrated FOC interface Fastest possible access to process data through dual port RAM Short response time with FastLogic Process-consistent data from a DP cycle
Higher computing performance in the PC by relieving the host CPU. Easy portability to other operating systems through a dual port RAM interface Implementation of motion control applications through support of the equidistant mode
Can also be used in high temperature industrial environments. Flexible application through switchable assignment of optical and electrical interface to master and slave
Optical PROFIBUS
Transfer mechanism DP Slave DP Master CP 5614 FO Distributed I/O FO RS 485 Switchable
PROFIBUS
SIMATIC ET 200M
SIMATIC ET 200S
Siemens IK PI 2001
3/357
G_IK10_deP0109s
Ordering data
9.6 kbit/s to 12 Mbit/s 2 duplex socket (FO) 9-pin Sub-D socket
9-pin Sub-D socket 2 duplex socket (FO) Low voltage socket 3.5 mm/1.3 mm + 5 V DC 5% 12 V DC 5% 1.6 A 0.3 A 8W 9 12 V DC 0.4 A 3.6 4.8 W
} DP-5613/Windows V6.0 Software for DP protocol incl. PG/OP communication, FDL, DP-OPC server; NCM PC under Windows NT 4.0 WS, server; Windows 2000 Pro, server; for CP 5613/ CP 5614/CP 5613 FO/CP 5614 FO; with electronic manual; on CD-ROM, in German/English } S7-5613/Windows V6.0 Software for S7 communication incl. PG/OP communication, FDL, S7-OPC server; NCM PC under Windows NT 4.0 WS, server; Windows 2000 Pro, server; for CP 5613/ CP 5614/CP 5613 FO/CP 5614 FO; with electronic manual; on CD-ROM, in German/English } FMS-5613/Windows V6.0 Software for FMS protocol incl. PG/OP communication, FDL, FMS-OPC server; NCM PC under Windows NT 4.0 WS, server; Windows 2000 Pro, server; for CP 5613/ CP 5614/CP 5613 FO/CP 5614 FO; with electronic manual; on CD-ROM, in German/English
PROFIBUS FastConnect RS 485 bus connector Plug 180 PROFIBUS 12M bus terminal
6GK1 713-5CB60-3AA0
Supply voltage (from PCI) Current consumption from 5 V DC from 12 V DC Power loss Supply voltage (optional) external power supply Current consumption Power loss Perm. ambient conditions Operating temperature Without fan With fan (air current 0.5 m/s) Transport/storage temperature Relative humidity Design Module format Dimensions (W H) in mm Weight Space required Performance data Single protocol mode No. of connectable DP slaves Data area of slave interface: input data, output data, diagnostics data No. of parallel FDL tasks to be processed No. of PG/OP and S7 connections No. of FMS connections
6GK1 713-5FB60-3AA0
max.
+5 C to +40 C +5 C to +60 C 40 C to +70 C 95% at +25 C PCI card 107 168 300 g 1 PCI slot
} }
6GK1 500-0FC00
approx.
PROFIBUS plastic fiber-optic, simplex plug / polishing set PROFIBUS plastic fiber-optic, stripping tool set Connection adapters 50 pcs.
max.
122
120 50 1) 402)
Manual CP 5613/CP 5614 and SOFTNET for PROFIBUS Paper version Including: Description of the interfaces (FMS, DP, S7, FDL), OPC server, configuration tools German English SIMATIC NET Software Update Service For Industrial Ethernet, PROFIBUS, OPC server including manuals, on CD-ROM, German/English SIMATIC NET Manual Collection Electronic manuals for communication systems, protocols, products on CD-ROM German/English 1) Download from the Internet at:
} } }
Ordering data
CP 5614 FO communications processor PCI card with master and slave connection to PROFIBUS, incl. Windows NT 4.0 WS, server, Windows 2000 Pro, server driver, DPRAM Interface for DP master and slave, configuration software with electronic manual on CD-ROM Development kit 1) DK-5613 Software development kit for CP 5613/CP 5614 for integration in any operating system environments on systems with PCI slot
Order No.
6GK1 561-4FA00
6GK1 975-1AA00-3AA0
http://www.siemens.de/simatic-net/dk5613
3/358
Siemens IK PI 2001
For connecting PG/PCs and notebooks with PCMCIA slot to PROFIBUS and MPI of the SIMATIC S7 Communication services: PROFIBUS-DP master class 1 with SOFTNET-DP. PROFIBUS-DP master class 2 including acyclic DP expansions with SOFTNET-DP. PROFIBUS-DP slave with SOFTNET-DP slave. PG/OP communication S7 communication with SOFTNET S7. S5-compatible communication (SEND/RECEIVE based on the FDL interface) with SOFTNET-DP or SOFTNET-S7. The CP 5511 enables connection of programming devices and AT-compatible PCs to PROFIBUS and to the multipoint interface (MPI) of SIMATIC S7:
PCMCIA card type II; for PG/PCs with PCMCIA slot and notebooks Used with: STEP 7, ProTool, NCM PC, Micro/Win, ProTool/Pro, SIMATIC PDM (for PG/OP communication) COM PROFIBUS SOFTNET S7 (for S7 communication). SOFTNET DP (for DP). OPC servers are supplied with the communication software
S5 C
FMS
OPC
Application
Design
PCMCIA card type II Adapter with 9-pin Sub-D socket for connection to PROFIBUS The following software packages support the CP 5511: STEP 7 as of V3.2 Drivers for the CP 5511 are supplied with STEP 7 SOFTNET-S7 The S7 programming interface can be used with this package SOFTNET-DP With this the CP 5511 can be used as a PROFIBUS-DP master class 1 or 2 SOFTNET-DP slave for using the CP 5511 as a PROFIBUS-DP slave
Functions
The CP 5511 is operated under different software packages and allows the user to execute programming device functions and PC functions through PROFIBUS and the multipoint interface (MPI). Only one CP can be operated for each PG/PC/notebook. Similarly only one protocol (PROFIBUS-DP, S7 communication or FDL) can be used for each CP.
COM PROFIBUS as of V3.3 With this package the CP 5511 can be used for commissioning or diagnostics (DP online functions) for PROFIBUS-DP systems STEP 7-Micro/Win as of V2.1 Hardware base for the programming software of the SIMATIC S7-200 programmable controller ProTool, ProTool/PRO The CP 5511 can be used as the hardware basis for the configuration tool for SIMATIC operator panels, touch panels and text displays. NCM PC drivers for the CP 5511 are included in delivery of the NCM PC.
Siemens IK PI 2001
3/359
Connection for notebooks or other portable PCs to PROFIBUS (e.g. for diagnostics and commissioning)
Technical specifications
Data transfer rate Interfaces Connection to PROFIBUS Connection to PG/PC Supply voltage Current consumption Power loss Perm. ambient conditions Operating temperature Transport/storage temperature Relative humidity 9.6 kbit/s to 12 Mbit/s 9-pin Sub-D socket PCMCIA slot type II +5 V DC 5% typ. 270 mA, max. 360 mA 1.8 W +5 C to +40 C 20 C to +60 C 95% at +25 C PCMCIA type II 54 85 5 30 g 130 g 1 PCMCIA slot type II
Ordering data
CP 5511 communications processor PCMCIA card for connecting a PG or PC to PROFIBUS or MPI SOFTNET-S7/Windows V6.0 Software for S7 communication incl. FDL, S7-OPC server, NCM PC under Windows NT 4.0 WS, server; Windows 2000 Pro, server; for CP 5511 and CP 5611, with electronic manual on CD-ROM SOFTNET-DP/Windows V6.0 Software for DP protocol (master class 1 and 2), FDL incl. DP-OPC server, NCM PC under Windows NT 4.0 WS, server; Windows 2000 Pro, server; for CP 5511 and CP 5611, with electronic manual on CD-ROM SOFTNET-DP Slave/Windows V6.0 Software for DP slave, incl. OPC server, under Windows NT 4.0 WS, server; Windows 2000 Pro, server; for CP 5511 and CP 5611, with electronic manual on CD-ROM PROFIBUS FastConnect RS 485 bus connector Plug 180 With 180 cable outlet Manual CP 5613/CP 5614 and SOFTNET for PROFIBUS Paper version Including: Description of the interfaces (FMS, DP, S7, FDL), OPC server, configuration tools German English SIMATIC NET Software Update Service For Industrial Ethernet, PROFIBUS, OPC server, including manuals, on CD-ROM, German/English SIMATIC NET Manual Collection Electronic manuals for communication systems, protocols, products on CD-ROM German/English
Order No.
6GK1 551-1AA00
6GK1 704-5CW60-3AA0
max.
6GK1 704-5DW60-3AA0
Design Module format Dimensions (W H D) in mm Weight without adapter approx. with adapter approx. Space required
6GK1 704-5SW60-3AA0
6GK1 500-0FC00
} } }
6GK1 975-1AA00-3AA0
3/360
Siemens IK PI 2001
For connecting PG/PC to PROFIBUS and MPI of the SIMATIC S7 Communication services: PROFIBUS-DP master class 1 with SOFTNET-DP. PROFIBUS-DP master class 2 including acyclic DP expansions with SOFTNET-DP. PROFIBUS-DP slave with SOFTNET-DP slave. PG/OP communication S7 communication with SOFTNET S7. S5-compatible communication (SEND/RECEIVE on the basis of the FDL interface) with SOFTNET-DP or SOFTNET-S7 The CP 5611 enables the connection of programming devices and PCs to PROFIBUS and multipointcapable MPI interfaces of the SIMATIC S7.
Short PCI card for programming device / PC with PCI slot. Used with: STEP 7, STEP 7-Micro/Win, SIMATIC NCM PC, ProTool, ProTool/Pro, SIMATIC PDM (for PG/OP communication) COM PROFIBUS SOFTNET-S7 (for S7 communication). SOFTNET DP (for DP). OPC servers are supplied with the communication software
S5 C
FMS
OPC
Application
Design
Short PCI card 9-pin Sub-D socket for connection to PROFIBUS The following software packages support the CP 5611: STEP 7 V3.2 upwards under Windows 95 and NT 4.0; Windows 98 from V4.02 and K4.02.5. Drivers for the CP 5611 are included in delivery of STEP 7. SOFTNET-S7 The S7 programming interface can be used with this package SOFTNET-DP With this the CP 5611 can be used as a PROFIBUS-DP master class 1 or 2 SOFTNET-DP Slave For using the CP 5611 as a PROFIBUS-DP slave
Functions
The CP 5611 is operated under different software packages and allows the user to execute programming device functions and PC functions through PROFIBUS and the multipoint interface (MPI). Only one CP can be operated for each programming device/PC. Similarly only one protocol (PROFIBUS-DP, S7 communication or FDL) can be used for each CP.
COM PROFIBUS as of V3.3 The CP 5611 can be used with this package for commissioning or diagnostics (DP online functions) for PROFIBUS-DP systems STEP 7-Micro/Win as of V2.1 Hardware base for the programming software of the SIMATIC S7-200 programmable controller ProTool, ProTool/PRO The CP 5611 can be used as the hardware basis for the configuration tool for SIMATIC operator panels, touch panels and text displays.
Siemens IK PI 2001
3/361
Connection for portable PCs to PROFIBUS (e.g. for diagnostics and commissioning)
Technical specifications
Data transfer rate Interfaces Connection to PROFIBUS 9.6 kbit/s to 12 Mbit/s 9-pin Sub-D socket +5 V DC 5% 0.5 A 2.0 W +5 C to +40 C 20 C to +60 C 95% at +25 C PCI card 102 130 100 g 1 PCI slot
Ordering data
CP 5611 communications processor PCI card for connecting a PG or PC to PROFIBUS CP 5611 MPI Consists of PCI card CP 5611 and MPI cable, 5 m SOFTNET-S7/Windows V6.0 Software for S7 communication incl. FDL, S7-OPC server, NCM PC under Windows NT 4.0 WS, server; Windows 2000 Pro, server; for CP 5511 and CP 5611, with electronic manual on CD-ROM SOFTNET-DP/Windows V6.0 Software for DP protocol (master class 1 and 2), FDL incl. DP-OPC server, NCM PC under Windows NT 4.0 WS, server; Windows 2000 Pro, server; for CP 5511 and CP 5611, with electronic manual on CD-ROM SOFTNET-DP Slave/Windows V6.0 Software for DP slave, incl. OPC server, under Windows NT 4.0 WS, server; Windows 2000 Pro, server; for CP 5511 and CP 5611, with electronic manual on CD-ROM PROFIBUS FastConnect RS 485 bus connector Plug 180 With 180 cable outlet
Order No.
6GK1 561-1AA00
Supply voltage Current consumption Power loss Perm. ambient conditions Operating temperature Transport/storage temperature Relative humidity Design Module format Dimensions (H D) in mm Weight Space required
} }
6GK1 561-1AM00
6GK1 704-5CW60-3AA0
max.
6GK1 704-5DW60-3AA0
approx.
6GK1 704-5SW60-3AA0
6GK1 500-0FC00
} PROFIBUS 12M bus terminal Bus terminal for connecting PROFIBUS stations up to 12 Mbit/s with connecting cable
Manual CP 5613/CP 5614 and SOFTNET for PROFIBUS Paper version Including: Description of the interfaces (FMS, DP, S7, FDL), OPC server, configuration tools German English SIMATIC NET Software Update Service For Industrial Ethernet, PROFIBUS, OPC server, including manuals, on CD-ROM, German/English SIMATIC NET Manual Collection Electronic manuals for communication systems, protocols, products on CD-ROM German/English
6GK1 500-0AA10
} } }
6GK1 975-1AA00-3AA0
3/362
Siemens IK PI 2001
CP 5611
CP 5511
PG/PC
S5 C
FMS
OPC
Can be used in conjunction with CP 5511 (PCMCIA), CP 5611 (PCI) and integrated PROFIBUS interface of the SIMATIC PG/PC/PC Communication services: PROFIBUS-DP master class 1 PROFIBUS-DP master class 2 with non-cyclic expansions PROFIBUS-DP slave PG/OP communication S7 communication S5-compatible communication (SEND/RECEIVE based on the FDL interface)
PROFIBUS
G_IK10_deP0039s
Application
SOFTNET for PROFIBUS can be used to connect PCs to automation systems, e.g. SIMATIC S7, through PROFIBUS. The following are available as user interfaces:
DP protocol PG/OP communication for SIMATIC S7 S7 communication S5-compatible communication (SEND/RECEIVE based on the FDL interface)
SOFTNET is available for the following interfaces: CP 5511 (PCMCIA card) CP 5611 (PCI card) Integrated PROFIBUS interfaces of SIMATIC programming devices/PCs. packages depends on the design and/or workload of the PCs used.
Principle of operation
This architecture means that, unlike CP 5613 or CP 5614 products the performance capability of the SOFTNET Devices of this type (programming devices, configuration devices or operating devices) are used on startup, on configuring the DP system or for operating the system during normal operation (e.g. diagnostics). The DP programming interface provides the following services: Master diagnostics, slave diagnostics, reading the inputs and outputs of a slave, reading configuration data and changing the slave address. The extended DP functions also include non-cyclic access to the parameters and measured values of a slave (e.g. field devices of the process automation, intelligent HMI devices. This type of slave must be supplied with extensive parameter data during startup and normal operation (DS_READ, DS_WRITE, DS_DATA_TRANSPORT).
Functions
Software for DP protocol (SOFTNET-DP) DP master class 1 SOFTNET-DP offers DP master class 1 functions in conjunction with the CP 5511 or CP 5611. In a fixed, repetitive message cycle, the central controller exchanges information with the DP slaves (e.g. ET 200S). The DP programming interface (DPLib.DLL) provides the PC programmer with function calls for data transfer. In addition, the DP interface offers the functions SYNC and FREEZE as well as the activation and deactivation of slaves. DP master class 2 In addition to DP master class 1 services, SOFTNETDP also offers DP master class 2 services.
DP slave (SOFTNET-DP slave) A DP slave is an I/O device that reads input information and supplies output information to the I/O. The quantity of input and output information depends on the type of device and can be up to 244 byte. The slave applications can be implemented on the PC using the functions SET_INPUT and SET_OUTPUT of the slave programming interface. Configuration of PROFIBUS-DP takes place with the enclosed COM PROFIBUS PC-Edition. For the slave interface, an example GSD file is provided which can be adapted to the relevant application.
Siemens IK PI 2001
3/363
3/364
Siemens IK PI 2001
Configuration of S7 communication protocols, S5-compatible communication, DP protocol (DP/DPV1/ DPV2) and FMS protocol is executed in STEP 7/NCM PC, V5.1+SP2 or higher. Low-cost integration as PROFIBUS-DP master class 1 or master class 2 with SOFTNET-DP. As a PROFIBUS-DP slave with SOFTNET-DP slave
The configuring tool NCM PC is included in delivery of the PROFIBUS software package.
Ordering data
DP interface SOFTNET-DP/Windows V6.0 Software for DP protocol (master class 1 and 2), FDL incl. DP-OPC server, NCM PC under Windows NT 4.0 WS, server; Windows 2000 Pro, server; for CP 5511 and CP 5611, with electronic manual on CD-ROM S7 communication SOFTNET-S7/Windows V6.0 Software for S7 communication incl. FDL, S7-OPC server, NCM PC under Windows NT 4.0 WS, server; Windows 2000 Pro, server; for CP 5511 and CP 5611, with electronic manual on CD-ROM SOFTNET-DP Slave/Windows V6.0 Software for DP slave, incl. OPC server, under Windows NT 4.0 WS, server; Windows 2000 Pro, server; for CP 5511 and CP 5611, with electronic manual on CD-ROM Manual CP 5613/CP 5614 and SOFTNET for PROFIBUS Paper version Including: Description of the interfaces (FMS, DP, S7, FDL), OPC server, configuration tools German English SIMATIC NET Software Update Service For Industrial Ethernet, PROFIBUS, OPC server, including manuals, on CD-ROM, German/English SIMATIC NET Manual Collection Electronic manuals for communication systems, protocols, products on CD-ROM German/English
Order No.
6GK1 704-5DW60-3AA0
6GK1 704-5CW60-3AA0
6GK1 704-5SW60-3AA0
} } }
6GK1 975-1AA00-3AA0
Siemens IK PI 2001
3/365
Industrial Ethernet
System interfacing for PG/PC
Overview
System interfacing for PG/PC
CP 1613 (PCI)
You can find software for the PC products under Windows on the SIMATIC NET/Windows CD including the relevant manuals in pdf format and comprehensive further information on SIMATIC NET products and communication. The necessary configuring tools are supplied with all software packages.
CP 1612 (PCI)
CP 1512 (PCMCIA)
Siemens IK PI 2001
4/123
Industrial Ethernet
System interfacing for PG/PC
Overview
Data throughput Industrial Ethernet A comparison between CP 1512, CP 1612 and CP 1413 (predecessor of CP 1613) and CP 1613 shows the course of the respective communication performance. With the appropriate software packages, this course fluctuates in CP 1512 and CP 1612 between 0 and the maximum throughput. Used with software packages, communication performance for the CP 1613 is stable and high, permitting fast response times without fluctuations.
Time
1)
Messages/s
CPU load
The communication must share the PC resources with other applications (especially HMI). In general, therefore, less than 25% of the host CPU time remains available for communication.
While under these conditions devices such as CPs 1512/1612 only lets through an average of approx. 80 messages (with strongly fluctuating curve), CP 1613 still offers maximum throughput.
The throughput specifications are mean values and depend on the individual system configuration of the PC.
Messages/s
CPU load
CP 1413
CP 1512 CP 1612
CP 1613
4/124
Siemens IK PI 2001
G_IK10_deI0038s
G_IK10_deI0037s
Industrial Ethernet
Introduction
System interfacing for PG/PC; OPC server
Overview OPC servers are included in delivery of the communication software Standard, open, manufacturer-independent interface Interfacing of OPC-capable Windows applications to S7 communication and S5compatible communication (SEND/RECEIVE). Builds upon software programming interfaces. Efficient data exchange for Windows NT 4.0 and Windows 2000 OPC scout as OPC client with browser functionality and OCX data control
PC/Windows NT and Windows 2000 SIMATIC NET OPC-Manager WinCC OPC-Client Microsoft Office OPC-Client
FMS-OPC server
DP-OPC server
S7-OPC server
S7-OPC server
FMS protocol
DP protocol
S7 comm.
S7-300
0 1
ET 200X
SIMATIC S5
PROFIBUS
Ind. Ethernet
S7-PC
G_IK10_deI0067s
Application
Under Windows NT and Windows 2000, OPC (OLE for Process Control) can be used as an extension to the communications interfaces COM (Component Object Model) and DCOM (Distributed COM) for the user software. The basic principle of OPC is that OPC client applications can communicate with the OPC server through a standard / open and thus multivendor interface. Can be integrated in OPCcapable Windows applications (Microsoft Office or HMI system) already commercially available.
For Industrial Ethernet, the following OPC servers are available: S7 OPC servers for S7 communication, alarms and events as well as S5-compatible communication (SEND/RECEIVE) The OPC servers have: Standardized access to SIMATIC S7 and SIMATIC S5 for OPC-capable applications under Windows NT and Windows 2000 Consistency between automation products from different manufacturers
Consistent and easy-to-use user interface for different components. Accessibility from every computer in the LAN High-performance data access through the Custom Interface (C++) Easy to use through the Automation Interface (VB) or OCX data control, which is supplied
Functions
Open standardization of addressing using logical names for objects of an automation component or system. Support of symbols from STEP 7 Efficient data exchange from a process component to a further processing application
Simultaneous use of several servers by one client application Several clients can run on one OPC server at the same time Server-specific configuration support Interfaces Custom Interface for high-performance C++ applications
Automation Interface for easy-to-create Visual Basic or similar applications OCX data control for direct integration in Windows applications that support COM/DCOM
Siemens IK PI 2001
4/125
Industrial Ethernet
Introduction
System interfacing for PG/PC; OPC server
Application X
Application Y
Server A
Server B
Server C
Configuration
4
Designed for Industry
The complete configuration of the communications parameters is executed with the tools of the installed Software Advanced PC Configuration (Configuration Console, SIMATIC NCM PC).
The following demo programs are included in delivery: For custom interface in C++ For Automation Interface with Visual Basic
Other compilers can be implemented through the OPC server, however, the compiler must support the COM interface (Microsoft Component Object Model)
Simple use of different networks and protocols through standard interface. Reduced training and learning requirements.
Easy integration in the system environment and office applications through C++ and Visual Basic interface Short programming times for applications.
Easy to handle and costeffective as delivery of the communication software includes the OPC server
Product versions
Product S7-1613 TF-1613 SOFTNET-S7 Industrial Ethernet contains OPC servers for: S7 communication S5-compatible communication S5-compatible communication S7 communication S5-compatible communication
Synchronous and asynchronous reading and writing of variables Monitoring of variables through the OPC server with alarm to the client in the event of change Use of quantity operations; this enables a large volume of data to be process in a short time Custom Interface (C++); OPC is therefore powerful Automation Interface (VB, Excel, Access, Delphi, etc.); therefore easy to use Graphics with OCX; allowing configuration instead of programming DP protocol S7 communication FMS protocol S5-compatible communication (SEND/RECEIVE) Windows NT 4.0 Workstation and server Windows 2000 Workstation and server
Interfaces
Protocols
Operating systems
4/126
Siemens IK PI 2001
G_IK10_deP0041s
FMS-OPC Server
S7-OPC Server
XY-OPC Server
DP-OPC Server
Industrial Ethernet
System interfacing for PG/PC
Advanced PC Configuration
Overview Advanced PC Configuration is included in delivery of the communications software from version 6.0 onwards. Simple handling thanks to automatic software installation, Plug & Play and user-prompted commissioning Simple, consistent and costeffective configuration and planning and design of a PC station Considerably simplified OPC configuration Advanced PC Configuration is delivered with the new configuring tool NCM PC and the tools Startup Wizard and Configuration Console.
Application
Advanced PC Configuration stands for a new, simple, consistent and cost-effective startup and diagnostics of a PC station. The Startup Wizard, Configuration Console and NCM PC mark the launch of a whole new world of tools.
The Startup Wizard guides the user through all the steps necessary to achieve a ready-to-run PC station The Configuration Console is the central tool for configuration settings and diagnostics
NCM PC V5.1+SP2 offers a new configuring tool for STEP 7-compatible PC configuration
Functions
Startup Wizard Simple and consistent startup of all modules and applications supported by Advanced PC Configuration. A wizard that takes the user step-by-step through the installation and configuration of the PC station.
Configuration Console The Configuration Console is a snap-in embedded in the Microsoft Management Console that offers a range of options for the configuration and diagnostics of PC hardware components and PC applications.
Settings on the OPC servers delivered with the communications software are also executed through the Configuration Console.
Siemens IK PI 2001
4/127
Industrial Ethernet
System interfacing for PG/PC
Advanced PC Configuration
Functions (continued) NCM PC NCM PC replaces the previous PC configuration tools COML S7 and COM PROFIBUS PC Edition. In future, PC configuration can be carried out in either STEP 7 or NCM PC, version V5.1+SP2 or higher. Both tools offer the same look & feel and create the same database. This ensures consistent configuration of protocols for S5-compatible communication, S7 communication, DP protocols and FMS protocols. No further need for multiple entries and data consistency is automatically ensured. A configuration wizard integrated in NCM PC also ensures user-prompted configuration of the PC station. With NCM PC and STEP 7, from Version V5.1+SP2, a PC can be configured in the same way as a SIMATIC S7 station and loaded through the network. This applies both to the local station on which NCM PC or STEP 7 is installed and the remote station that is operated through the network.
Note: NCM PC does not contain a conversion for LDBs that were created with COM PROFBUS or COML S7. In this case these must be re-configured. For further information on Advanced PC Configuration and the previous versions of PC/Windows software products please visit us in the Internet at:
http://www.siemens.de/ simatic-net/ik-info_en
Advanced PC Configuration
4/128
Siemens IK PI 2001
Industrial Ethernet
System interfacing for PG/PC
Advanced PC Configuration
Designed for Industry Simple use of different networks and protocols through standard configuration. Reduced training and learning requirements. Short setting times for communication Uniform procedure and configuration functionality, as for STEP 7
Ordering data
Advanced PC Configuration
Order No. The following products are included in the scope of supply: S7-1613 PG-1613 SOFTNET-PG for Industrial Ethernet SOFTNET-S7 for Industrial Ethernet SIMATIC NET CD 07/2001 Upgrade
CP 1512, CP 1612, CP 1613 CP 1612 compatible PROFIBUS interfaces of PCs/PGs S5-compatible communication S7 communication Windows NT 4.0 SP 6a Windows 2000 +SP1 for Professional and servers
Siemens IK PI 2001
4/129
Industrial Ethernet
PG/PC
CP 1613 communications processor
Overview
ISO TCP/IP PG/OP S7 C
PCI card with microprocessor for connecting PG/PC to Industrial Ethernet with 10/100 Mbit/s autosensing Communication services through ISO or TCP/IP transport protocols PG/OP communication S7 communication S5-compatible communication (SEND/RECEIVE) TF protocol
Delivery of the communication software includes the OPC servers. 15-pin AUI/ITP RJ45 connection ISO and TCP/IP transport protocol onboard Large quantity framework
S5 C
IT
TF
OPC
Design
The CP 1613 module (card with microprocessor) is plugged directly into a SIMATIC PG/PC or a PC and requires a short PCI slot.
4
Mode of operation The module independently processes the protocols up to and including level 4 (transport). To permit a large quantity framework and high communication integrity, 16 MB of memory are provided. User interfaces OPC interface The OPC server contained in the respective software package can be used as a standard programming interface for the protocols S7 communication and S5-compatible communication to connect automation applications to OPC-capable Windows applications (Office, HMI systems etc.).
Connections: 15-pin Sub-D socket for use in industrial applications (automatic switching between AUI, ITP and RJ45 interface) RJ45 for connection in the office environment
In the case of electrical networks, forexample the module is connected to the 727-0 bus through a 727-1 connecting cable/ transceiver. for ITP through the ITP standard cable 9/15 to OSM/ESM/star coupler for optical networks through the Mini OTDE optical transceiver. The data transfer between the host system and the CP 1613 is handled by a Windows NT driver or Windows 2000 driver. The transfer rate is detected and automatically switched over (autosensing).
The data exchange between module and host takes place in master mode. This means that the CP 1613 accesses the physical RAM of the host.
Functions
Programming interface through C library The programming interfaces for the protocols S7 communication, PG/OP communication, S5-compatible communication and TF protocol for existing applications are implemented as a Dynamic Link Library (DLL). The following compilers can therefore be used in conjunction with the SIMATIC NET products: Microsoft Visual C/C++ V6.0 Microsoft Visual Basic V6.0 Other compilers can be implemented through the OPC server, however, the compiler must support the COM interface (Microsoft Component Object Model)
Software for PG/OP communication This software permits programming of SIMATIC S5 and S7 PLCs through Industrial Ethernet in combination with STEP 5/STEP 7 automation systems. It is contained in all CP 1613 software packages.
4/130
Siemens IK PI 2001
Industrial Ethernet
System interfacing for PG/PC
CP 1613 communications processor
Application The CP 1613 enables connection to Industrial Ethernet (10/100 Mbit/s) for SIMATIC PG/Industrial PC and PCs with PCI slot.
10 Mbit/s
Triaxial network
Transceiver
10/100 Mbit/s
CP 1613
4
10/100 Mbit/s
Structured cabling according EN 50173 Twisted pair switch (e.g. ESM TP80)
FC Outlet RJ45
FC Outlet RJ45
RJ45
100 Mbit/s
OSM BC08
Siemens IK PI 2001
4/131
G_IK10_deI0051s
RJ45/RJ45 TP Cord
Industrial Ethernet
System interfacing for PG/PC
CP 1613 communications processor
Functions (continued) Software for S7 communication (S7-1613 or S7-REDCONNECT) The S7 programming interface enables PG/PC applications (e.g. WinCC) and application programs access to SIMATIC S7/ system components. Thus, easy and flexible access to the data of the SIMATIC S7/M7 is possible. S7 communication provides: Administrative services Link management Mini database Trace Data transfer services Reading/writing of variables BSEND/BRECEIVE With S7-REDCONNECT, communication with the highavailability S7-400H system is possible.
Software for S5-compatible communication (SEND/RECEIVE) This layer 4 based interface is used for communication between PG/PC and SIMATIC S5 PG/PC and SIMATIC S7 PG/PC and PG/PC S5-compatible communication (SEND/RECEIVE) provides the following services: Management services Connection establishment services Data transfer services The software is contained in the products S7-1613 and TF-1613.
Software for TF protocol (TF-1613) The technological functions interface offers access to the MAP 3.0 open and wellproven automation protocol on Ethernet. The Technological Functions correspond in functionality to the international MMS services in accordance with ISO IS 9506. MMS/TF services: Variable services Domain services Program invocation services General services for virtual devices (VMD support service) Services of TF link management (environment and general management services).
Configuration
Configuration of S7 communication protocols and S5compatible communication is executed in STEP 7/ NCM PC, V5.1 SP2 or higher. The TF configuration is executed using COML TF.
The configuring tools NCM PC and COML TF are included in delivery with the CP 1613 software packages. NCM PC is a component of Advanced PC Configuration.
For further information on Advanced PC Configuration and the previous versions of PC/Windows software products please visit us in the Internet at:
http://www.siemens.de/ simatic-net/ik-info_en
Continuous data throughput through protocol processing on the CP. Can be connected to any Ethernet network through AUI/ITP or RJ45 ports on the module.
Free computer capacity for further applications in the PC, e.g. HMI (ISO and TCP/IP transport onboard) Simple handling through plug & play and autosensing (10/100 Mbit/s).
Operation of large network configurations with one card due to large number of connections Can be used for redundant communication. OPC as common interface
4/132
Siemens IK PI 2001
Industrial Ethernet
System interfacing for PG/PC
CP 1613 communications processor
Technical specifications
Data transfer rate Interfaces Connection to Industrial Ethernet (10/100 Mbit/s)
10BaseT,
Ordering data
10/100 Mbit/s 15-pin Sub-D socket (autom. switching between AUI and twisted pair) RJ45 5 V DC 5% 12 V DC 5% 600 mA 500 mA 4W +5 C to +40 C 20 C to +60 C 95% at +25 C Short AT format 107 x 167 200 g 1 x PCI slot CP 1613 PCI card for connection to Industrial Ethernet (10/100 Mbit/s) with AUI/ITP and RJ45 port
Order No.
6GK1 161-3AA00
100BaseTX
Supply voltage Current consumption From 5 V DC From 12 V DC Power loss Perm. ambient conditions Operating temperature Transport/storage temperature Relative humidity Design Module format Dimensions (W x D) in mm Weight Space required Performance data Single protocol mode S7 and PG/OP communication No. of usable connections ISO TCP/IP S5-compatible communication (SEND/RECEIVE) No. of usable connections ISO TCP/IP
} S7-1613/Windows V6.0 Software for S7-Communication S5-compatible communication (SEND/RECEIVE) incl. OPC, PG/OP-Communication, NCM PC, up to 120 connections, under Windows NT 4.0 WS, server; Windows 2000 Pro, server for CP 1613 with electronic manual on CD-ROM German/English } TF-1613/Windows V6.0 Software for TF protocol, S5-compatible communication, incl. OPC, PG/OP communication under Windows NT 4.0 WS, server; Windows 2000 Pro, server for CP 1613 with electronic manual on CD-ROM German/English } PG-1613/Windows V6.0 Software for PG/OP communication, NCM PC, under Windows NT 4.0 WS, server; Windows 2000 Pro, server for CP 1613, with electronic manual on CD-ROM German/English
S7-REDCONNECT/Windows V1.4 } Software for fail-safe S7 communication through redundant networks, incl. S7-OPC server under Windows NT 4.0 WS, server; Windows 2000 Pro, server; for CP 1613, with electronic manual on CD-ROM German/English Upgrade S7-REDCONNECT/ Windows V1.4 For expansion of S7-1613/Windows on S7-REDCONNECT/Windows V1.4, under Windows NT 4.0 WS, server; Windows 2000 Pro, server; with electronic manual on CD-ROM German/English CP 1613 and SOFTNET for Industrial Ethernet manual Hardcopy version: contains description of the interfaces (S7, TF, S5-compatible communication), OPC server, configuring tool for CP 1613 German English SIMATIC NET Manual Collection Electronic manuals for communication systems, protocols, products on CD-ROM German/English SIMATIC NET Software Update Service for Industrial Ethernet, PROFIBUS, OPC server, including manuals, on CD-ROM, German/English
6GK1 716-1CB60-3AA0
6GK1 716-1TB60-3AA0
max.
approx.
6GK1 716-1PB60-3AA0
max. max.
120 120
4
6GK1 716-0HB14-3AA0 6GK1 716-0HB14-3AA4
max. max.
120 120
} } }
6GK1 704-0AA00-3AA2
Siemens IK PI 2001
4/133
Industrial Ethernet
System interfacing for PG/PC
S7-REDCONNECT
Overview
ISO TCP/IP PG/OP S7 C
PC with S7-REDCONNECT and 2 x CP 1613
G_IK10_deI0048s
For connection of PCs for redundant Industrial Ethernet to SIMATIC S7-400H For redundantly structured Industrial Ethernet. Operation is also possible in non-redundant networks.
S5 C
IT
TF
OPC
Industrial Ethernet Industrial Ethernet
Completely integrated in STEP 7 from V5.0. Delivery of the communication software includes the OPC servers
S7-400H
S7-400H
Application
The software package S7-REDCONNECT connects the SIMATIC S7-400H to applications on the PC, e.g. WinCC.
Typically, a redundant Industrial Ethernet is used. The software package can also be used where SIMATIC H systems are operated on nonredundant networks. PC with: up to four CP 1613 and S7-REDCONNECT for connecting the PC to Industrial Ethernet with ISO-Protocol under Windows NT4.0, 2000 Pro Fault detection, switching over if required, communication monitoring and synchronization are handled in the background invisible to the application.
Design
The following components are necessary for assembling a SIMATIC H system with PC connection
S7-400H with: CP 443-1 for connecting the S7-400H to Industrial Ethernet with ISO protocol STEP 7 from V5.0 upwards for configuring.
Mode of operation
The highly available S7 communication is fed through a master and a reserve connection concealed for the application which is monitored during operation and switched over in the event of a fault.
The application, e.g. WinCC, communicates with the 2 subunits of the S7-400H in the same way as with an S7 CPU.
Functions
S7-REDCONNECT contains the functional scope of the S7-1613 software package (S7 communication, S5-compatible communication and PG/OP communication) as well as additional redundant communication through S7 connections. An additional licence for S7-1613 is not required. S5-compatible communication Time-of-day synchronization Continued use of existing Windows applications Services for monitoring the redundant communication. Diagnostics tool for visualizing the communication status
Simple redundancy through 2-way communication (STEP 7 V5.0 SP2 or higher) Increased redundancy through 4-way communication (STEP 7 V5.1 or higher)
User interfaces OPC interface The OPC server contained in the respective software package can be used as a standard programming interface for the protocols S7 communication and S5-compatible communication to connect automation applications to OPC-capable Windows applications (Office, HMI systems etc.).
Programming interface through C library The programming interfaces for the protocols S7 communication, PG/OP communication, S5-compatible communication and TF protocol for existing applications are implemented as a Dynamic Link Library (DLL). The following compilers can therefore be used in conjunction with the SIMATIC NET products: Microsoft Visual C/C++ V6.0 Microsoft Visual Basic V6.0
4/134
Siemens IK PI 2001
Industrial Ethernet
System interfacing for PG/PC
S7-REDCONNECT
Configuration
PC with S7-REDCONNECT and 2 x CP 1613 PC
OSM OSM
OSM OSM
S7-300
OSM OSM
10/100 Mbit/s
Third-party system
100 Mbit/s
OSM OSM
S7-400
OSM OSM OSM OSM
H system
S7-400
S7-400
H system
G_IK10_deI0053s
Configuration
The configuration established for the PCs with STEP 7 from V5.0 is written to files and transferred to the PCs.
Provides protection against communication failure in the event of a fault in the double bus or in redundant rings. Simplifies communication of a PC application with the SIMATIC S7-400H system.
Safeguards previous investments due to the use of existing applications and the flexible application options. No additional programming required for PC and H systems.
Increases the availability of the PC application (e.g.PC S7) through redundant communication
Ordering data
S7-REDCONNECT/Windows V1.4 } Software for fail-safe S7 communication through redundant networks incl. S7-OPC server under Windows NT 4.0 WS, server; Windows 2000 Pro, server; for CP 1613, with electronic manual on CD-ROM German/English Upgrade S7-REDCONNECT/ Windows V1.4 For expansion of S7-1613/Windows on S7-REDCONNECT/Windows V1.4, under Windows NT 4.0 WS, server; Windows 2000 Pro, server; with electronic manual on CD-ROM German/English
6GK1 716-0HB14-3AA4
Siemens IK PI 2001
4/135
Industrial Ethernet
System interfacing for PG/PC
CP 1612 communications processor
Overview
ISO TCP/IP PG/OP S7 C
For connection of PG/PC with PCI slot to Industrial Ethernet with 10/100 Mbit/s Communication services through ISO or TCP/IP transport protocols PG/OP communication S7 communication S5-compatible communication (SEND/RECEIVE)
Designed for use in industrial environments. PCI card Interfaces: RJ45 (Twisted Pair) Plug&Play Delivery of the communication software includes the OPC servers
S5 C
IT
TF
OPC
Application
The CP 1612 is an Ethernet card that can be operated in any PG/PC with a free PCI slot. It supports the Plug & Play mechanism of the operating system. The CP 1612 offers the following accesses: Layer 2: Interfacing for PC networks in an industrial environment.
The CP 1612 can be operated with all SOFTNET for Industrial Ethernet packages.
Design
Mode of operation
Layer 4 and layer 7. In conjunction with the SOFTNET packages for Industrial Ethernet, the CP 1612 offers low-cost access to Industrial Ethernet, e.g.to SIMATIC S5/S7. The configuring tool NCM PC is included in delivery with the software packages SOFTNET-S7 and SOFTNET-PG for Industrial Ethernet. NCM PC is a component of Advanced PC Configuration.
In addition, the protocols for Industrial Ethernet provided by the operating system are also supported.
Configuration
Configuration of S7 communication protocols and S5compatible communication is executed in STEP 7/ NCM PC, V5.1 SP2 or higher.
For further information on Advanced PC Configuration and the previous versions of PC/Windows software products please visit us in the Internet at:
http://www.siemens.de/ simatic-net/ik-info_en
4/136
Siemens IK PI 2001
Industrial Ethernet
System interfacing for PG/PC
CP 1612 communications processor
Designed for Industry
Connection option RJ45 Optimized for SOFTNET. Ideal for small installations.
Technical specifications
Data transfer rate Interfaces Connection to Industrial Ethernet Supply voltage Current consumption From 5 V DC Power loss Perm. ambient conditions Operating temperature Transport/storage temperature Relative humidity Design Module format Dimensions (H x D) in mm Weight Space required approx. max. 10/100 Mbit/s RJ45 +5 V DC 5% 200 mA 1W 0 C to +50 C 25 C to +55 C 95% at +25 C Short AT format 51 x 120 100 g 1 x PCI slot
Ordering data
} CP 1612 PCI card for connection of a PG/PC to Industrial Ethernet (10/100 Mbit/s), with RJ45 connector through SOFTNET-S7 and SOFTNET-PG } SOFTNET-S7/Windows V6.0 for Industrial Ethernet Software for S5-compatible communication (SEND/RECEIVE) and S7 communication, incl. OPC server, PG/OP communication, NCM PC, up to 64 connections, under Windows NT 4.0 WS, server; Windows 2000 Pro, server for CP 1612/CP 1512 with electronic manual on CD-ROM German/English
SOFTNET-PG/Windows V6.0 for Industrial Ethernet Software for PG/OP communication, NCM PC, under Windows NT 4.0 WS, server; Windows 2000 Pro, Server for CP 1612/CP 1512, with electronic manual on CD-ROM German/English SOFTNET-PG/Windows V3.3 Software for PG/OP communication, under Windows Me, with electronic manual on CD-ROM German/English CP 1613 and SOFTNET for Industrial Ethernet manual Paper version Including: Description of interfaces (S7, S5-compatible communication), OPC server, configuring tool German English SIMATIC NET Software Update Service for Industrial Ethernet, PROFIBUS, OPC server, including manuals on CD-ROM SIMATIC NET Manual Collection Electronic manuals for communication systems, protocols, products on CD-ROM German/English
6GK1 704-1CW60-3AA0
max.
approx. approx.
6GK1 704-1PW60-3AA0
6GK1 704-1PW33-3AA0
} } }
6GK1 975-1AA00-3AA0
Siemens IK PI 2001
4/137
Industrial Ethernet
System interfacing for PG/PC
CP 1512 communications processor
Overview
ISO TCP/IP PG/OP S7 C
For connection of PG/ notebooks with PCMCIA slot (CardBus interface 32 bit) to Industrial Ethernet with 10/100 Mbit/s Communication services through ISO or TCP/IP transport protocols PG/OP communication S7 communication S5-compatible communication (SEND/RECEIVE)
Designed for use in industrial environments. PCMCIA card type II Interfaces: RJ45 (Twisted Pair) Plug&Play Delivery of the communication software includes the OPC servers
S5 C
IT
TF
OPC
Application
CP 1512 is an Ethernet card which can be operated in any PG/PC with one a free PCMCIA slot type II with CardBus interface (32-bit).
In conjunction with all SOFTNET packages for Industrial Ethernet (except UNIX), the CP 1512 can be used (e.g.) in a notebook for remote programming (PG/OP communication).
Design
Supports the Plug&Play mechanism of the operating system. The CP 1512 offers the following accesses: Layer 2: Interfacing for PC networks in an industrial environment.
Mode of operation
Layer 4 and layer 7. In conjunction with the SOFTNET packages for Industrial Ethernet, the CP 1512 offers low-cost access to Industrial Ethernet, e.g. to the SIMATIC S5/S7. The configuring tool NCM PC is included in delivery with the software packages SOFTNET-S7 and SOFTNET-PG for Industrial Ethernet. NCM PC is a component of Advanced PC Configuration.
In addition, the protocols for Industrial Ethernet provided by the operating system are also supported.
Configuration
Configuration of S7 communication protocols and S5compatible communication is executed in STEP 7/ NCM PC, V5.1 SP2 or higher.
For further information on Advanced PC Configuration and the previous versions of PC/Windows software products please visit us in the Internet at:
http://www.siemens.de/ simatic-net/ik-info_en
4/138
Siemens IK PI 2001
Industrial Ethernet
System interfacing for PG/PC
CP 1512 communications processor
Configuration
Production Level
PC with CP 1613 and WinCC
Control Room
PG/Notebook with CP 1512
S7-400
S7-400
S7-400
ESM ITP80
ESM
FC Standard Cable
TP Cord 9 / RJ45
Outlet RJ45
G_IK10_deI0068s
Siemens IK PI 2001
4/139
Industrial Ethernet
System interfacing for PG/PC
CP 1512 communications processor
Technical specifications
Data transfer rate Interfaces Connection to Industrial Ethernet Connection to PG/PC Supply voltage Current consumption Perm. ambient conditions Operating temperature Transport/storage temperature Relative humidity Construction of the CP 1512 Module format Dimensions (H x W x D) in mm Weight Space required Construction of adapter Dimensions (W x H x D) in mm approx. Weight approx. Cable length approx. max. 10/100 Mbit/s RJ45 PCMCIA Slot type II (CardBus 32 bit) 3.3 V DC, 5% 0.18 A 0 C to +55 C 20 C to +80 C 90% at +25 C PCMCIA type II 85.6 x 54 x 5 30 g 1 x PCMCIA slot type II RJ45 40 x 22 x 20 40 g 20 cm
Ordering data
} CP 1512 PCMCIA card (CardBus 32 bit) for connection of PG/PC to Industrial Ethernet incl. adapter for RJ45, through SOFTNET-S7 and SOFTNET-PG
max.
} 6GK1 704-1CW60-3AA0 SOFTNET-S7/Windows V6.0 for Industrial Ethernet Software for S5-compatible communication (SEND/RECEIVE) and S7 communication, incl. OPC server, PG/OP communication, NCM PC, up to 64 connections, under Windows NT 4.0 WS, server; Windows 2000 Pro, server for CP 1612/CP 1512 with electronic manual on CD-ROM German/English
SOFTNET-PG/Windows V6.0 for Industrial Ethernet Software for PG/OP communication, NCM PC, under Windows NT 4.0 WS, server; Windows 2000 Pro, Server for CP 1612/CP 1512, with electronic manual on CD-ROM German/English SOFTNET-PG/Windows V3.3 Software for PG/OP communication, under Windows Me, with electronic manual on CD-ROM German/English SIMATIC NET Software Update Service for Industrial Ethernet, PROFIBUS, OPC server, including manuals, on CD-ROM, German/English CP 1613 and SOFTNET for Industrial Ethernet manual Paper version includes: Description of interfaces (S7, S5-compatible communication), OPC server, configuration German English SIMATIC NET Manual Collection Electronic manuals for communication systems, protocols, products on CD-ROM German/English
6GK1 704-1PW60-3AA0
6GK1 704-1PW33-3AA0
6GK1 704-0AA00-3AA2
} } }
4/140
Siemens IK PI 2001
Industrial Ethernet
System interfacing for PG/PC
SOFTNET for Industrial Ethernet
Overview
ISO TCP/IP PG/OP S7 C
CP 1512 CP 1612 PC/PG SOFTNET for Industrial Ethernet
For connecting programming devices/PCs/ workstations with automation systems. Communication services: PG/OP communication S7 communication S5-compatible communication (SEND/RECEIVE) Can be used in conjunction with CP 1612 (PCI), CP 1512 (PCMCIA) Modem (Remote Access Service RAS)
S5 C
IT
TF
OPC
Industrial Ethernet
S5-115U to -155U with CP 1430 TF S7-400 with CP 443-1
G_IK10_deI0040s
Complete protocol stack as software package. OPC servers are included in delivery of the communication software SOFTNET is available for the following interfaces: CP 1612 (PCI card) CP 1512 (PCMCIA card). Modem (RAS)
Application
Using SOFTNET for Industrial Ethernet PG/PC/Workstations can be coupled with programmable controllers, e.g. SIMATIC S7, through Industrial Ethernet.
The following are available as user interfaces: PG/OP communication for SIMATIC S7 S5-compatible communication (SEND/RECEIVE) for communication with SIMATIC S7 S7 communication Unlike the 1613 products, the performance capability of the SOFTNET packages with this The following compilers can therefore be used in conjunction with the SIMATIC NET products: Microsoft Visual C/C++ V6.0 Microsoft Visual Basic V6.0 Other compilers can be implemented through the OPC server, however, the compiler must support the COM interface (Microsoft Component Object Model) Software for PG/OP communication This software allows programming of the SIMATIC S5 and S7 controllers through Industrial Ethernet in conjunction with STEP 5/STEP 7. Software for S7 communication SIMATIC S7 system components communicate with each other through S7 communication. The S7 communications can optionally be based on the ISO protocol or the TCP/IP protocol.
Mode of operation
architecture depends on the network extension and/or workload of the PC used. S7 communication offers the following services: Administrative services S7 connection management services Variables services VFD (virtual field device) services Trace and Mini database. S5-compatible communication (SEND/RECEIVE) This layer 4 based interface (ISO transport or TCP/IP with RFC 1006) is used for communication between PG/PC and SIMATIC S5 PG/PC and SIMATIC S7 PG/PC and PG/PC S5-compatible communication (SEND/RECEIVE) provides the following services: Management services Connection establishment services Data transfer services
Functions
User interfaces OPC interface The OPC server contained in the respective software package can be used as a standard programming interface for the protocols S7 communication and S5-compatible communication to connect automation applications to OPC-capable Windows applications (Office, HMI systems etc.). Programming interface through C library The programming interfaces for the protocols S7 communication, PG/OP communication, S5-compatible communication and TF protocol for existing applications are implemented as a Dynamic Link Library (DLL).
Siemens IK PI 2001
4/141
Industrial Ethernet
System interfacing for PG/PC
SOFTNET for Industrial Ethernet
Configuration
The complete configuration of S7 communication protocols and S5-compatible communication is executed in STEP 7/NCM PC, V5.1 SP2 or higher.
NCM PC is a component of Advanced PC Configuration. The configuring tool NCM PC is included in delivery of the relevant software packages.
For further information on Advanced PC Configuration and the previous versions of PC/Windows software products please visit us in the Internet at:
http://www.siemens.de/ simatic-net/ik-info_en
Can be used in notebooks with PCMCIA slot. Optimized for small installations.
Technical specifications
Performance data S7 and PG/OP communication SOFTNET-S7: Number of operable connections
Ordering data
max.
64
} SOFTNET-S7/Windows V6.0 for Industrial Ethernet Software for S5-compatible communication (SEND/RECEIVE) and S7 communication, incl. OPC server, PG/OP communication, NCM PC, up to 64 connections, under Windows NT 4.0 WS, server; Windows 2000 Pro, server for CP 1612/CP 1512 with electronic manual on CD-ROM German/English
SOFTNET-PG/Windows V6.0 for Industrial Ethernet Software for PG/OP communication, NCM PC, under Windows NT 4.0 WS, server; Windows 2000 Pro, Server for CP 1612/CP 1512, with electronic manual on CD-ROM German/English SOFTNET-PG/Windows V3.3 Software for PG/OP communication, under Windows Me, with electronic manual on CD-ROM German/English CP 1613 and SOFTNET for Industrial Ethernet manual Paper version Including: Description of interfaces (S7, S5-compatible communication), OPC server, configuring tool German English SIMATIC NET Manual Collection Electronic manuals for communication systems, protocols, products on CD-ROM German/English SIMATIC NET Software Update Service for Industrial Ethernet, PROFIBUS, OPC server, including manuals on CD-ROM
6GK1 704-1PW60-3AA0
6GK1 704-1PW33-3AA0
} } }
6GK1 704-0AA00-3AA2
4/142
Siemens IK PI 2001