The Smart View To Energy Efficiency
The Smart View To Energy Efficiency
Take your next step with these FREE materials from Schneider Electric.
Visit www.SEreply.com and enter key code or call 000-000-0000
Read how energy and environmental responsibility lie at the core of the Schneider Electric strategy.
Achieve permanent change through measurement, monitoring, and control of your energy usage.
Sign up for our FREE, flexible training so you can develop new, more efficient solutions.
Micrologic E
Make the most of your energy
Schneider Electric Industries SAS Head Office 35 rue Joseph Monier 92500 Rueil Malmaison Cedex- France Tel.: +33 (0)1 41 29 70 00 www.schneider-electric.com
SM
Control unit for Compact NS630b to NS3200 and Masterpact NT/NW circuit breakers
2010 Schneider Electric Industries SAS, All Rights Reserved. Schneider Electric, Active Energy Management, Compact, EcoStruxure, ION Enterprise, iRIO, Make the most of your energy, Masterpact, Micrologic, Power Plant To Plug, and PowerLogic are owned by Schneider Electric, or its affiliated companies in the United States and other countries. 998-3432
Buildings can achieve up to 30% energy savings with an Active Energy Management programme that includes an energy metering system.*
Micrologic E
Energy efficiency, now within your reach
As energy costs increase and more stringent greenhouse gas emissions regulations are introduced, its essential to find ways to reduce energy consumption. Distributed energy metering is a critical first step. It will help you understand exactly where, when, and how much energy you are consuming throughout your facilities so you can discover opportunities to improve your efficiency. The new Micrologic E control unit for Compact NS and Masterpact NT/NW circuit breakers puts energy metering at key points across your power grid in a way that is:
The Micrologic E control unit is making intelligent, energy measurement-capable circuit breakers the new industry standard.
* Programmes can also include the use of automation and control systems, monitoring and maintenance services, energy acquisition optimization, and renewable energy sources.
Smart
It avoids the additional costs and panel space associated with installing a separate energy meter with current transformers.
The Micrologic E bridges the gap in the Micrologic family of industry-leading control units, joining a legacy of safety, flexibility, and ease of use.
No metering A ammeter E energy P power H harmonics
Measurements
Current demand, voltage, power factor, power, power demand, and energy* Cos-j, frequency, per phase measurements (power, energy, PF,) and advanced protection Power quality (harmonics 31st order), waveform capture, enhanced alarm programming 2 (L, I): long time, instantaneous 5 (L, S, I): long time, short time, instantaneous 6 (L, S, I, G): long time, short time, instantaneous, earth fault
7 ( L, S, I, V): long time, short time, instantaneous, earth leakage up to 3200A
2.0 5.0
* Active, reactive, and apparent power and energy. Accuracy of active energy is 2 percent (including the sensors).
A MWh
MWh
V MW
MW V
>
Trip history for easy troubleshooting. The last ten trips are always memorized in non-volatile memory. View these through the Micrologic E display or through software, with each event including the trip cause, date, and time stamp.
Safe
Protection and metering units are safely separated.
Date of trip
Time of trip
The scrolling display means you dont need to touch the panel.
>
Sensor
Air Core CT
ASIC
Protection
Two relay outputs for coordinated control. Two M2C type relays are driven by trip events for a flexible choice of management functions. For example, a ground fault trip assigned to one output enables interlocking with medium voltage equipment.
The trip history is viewable through the Micrologic E display or through software, supporting easy troubleshooting.
Microprocessor
Automatically collect data from circuit breakers, meters, and sensors across your facility
Simple
Mod bus BCM ULP
FDM 121
Remote Control Utility (RCU) for simple data access and circuit breaker control
iRIO RTU or EGX300 gateway for data viewable using a standard web browser
PowerLogic ION Enterprise software for advanced energy and power quality analysis
Micro
logic
Facility and corporate managers analyse energy efficiency and costs, while maintenance personnel analyse electrical system reliability.
Thinking ahead
By including a Micrologic E control unit in each of your Compact NS and Masterpact NT/NW circuit breakers, youre making an important first step toward improved energy efficiency, in a way that is smart, safe and simple. Schneider Electric can help you take the next steps necessary to achieve maximum efficiency for your entire building. We are the only global specialist in energy management providing an integrated approach to help youapproach to active energy efficiency Our meet your efficiency targets.
1 Measure
4 maintain,
improve
Metering, monitoring, and consulting services, EE analysis software
Monitor,
Passive Active EE Solutions Sustained Energy The path to sustainable savings Savings
The levels of efficiency required for effective energy management involve system dynamics across platforms and providers like never before. With our innovative EcoStruxure approach, we provide an Active Energy Management architecture from Power Plant to Plug to create intelligent energy management systems. These systems are simplified, save money, and reduce waste by guaranteeing compatibility between the management of power, process and machines, IT rooms, buildings, and security.
30%
Schneider Electric can help deliver up to 30% energy savings in industrial and commercial buildings.
12 9