0% found this document useful (0 votes)
42 views

Isolated Footing

This document provides design details for three isolated footings (F1, F2, F3). It specifies dimensions, reinforcement, and checks shear and development length. F1 and F3 are designed with minimum reinforcement requirements met. F2 requires more steel due to higher loads but meets all checks.
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
42 views

Isolated Footing

This document provides design details for three isolated footings (F1, F2, F3). It specifies dimensions, reinforcement, and checks shear and development length. F1 and F3 are designed with minimum reinforcement requirements met. F2 requires more steel due to higher loads but meets all checks.
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

DESIGN OF ISOLATED FOOTING

Footing notation Length of footing L (mm) Width of footing B (mm) Length of column l (mm) Width of column b (mm) Grade of concrete Clear cover Maximum soil pressure (kN/m2) Minimum soil pressure (kN/m2) Projection of footing x (mm) Maximum bending moment M (kN.m) Balance design parameters (ku, Ru, pt) Depth required (mm) Provide overall depth D (mm) Depth at free end D1 (mm) \ Effective depth d (mm) Reinforcement Area of reinforcement (mm2) Provide dia of bar (mm) Spacing of bar provided (mm) \ pt provided (%) F1 1200 1000 600 230 M 20 50 450.0 449.0 385 33.4 134.7 300 200 245 F2 F3 1500 2650 1000 2650 600 600 230 230 M 20 M 20 50 50 592.0 50.0 578.0 27.0 450 1210 59.9 36.6 0.48 , 2.76 MPa, 0.96 % 180.6 141.2 350 350 200 200 294 295

390.1 10 200 0.16

589.5 12 190 0.20

347.0 10 200 0.13

Check for one way shear Critical section at distance 'd' from the face of column Depth available at section 208.6 Pressure coordinate at section (kN/m2) 450.0 Shear force V (kN) 63.0 2 Shear resisting area A (mm ) 179427.27 2 0.35 Shear stress t= V / A (N/mm ) Permissible stress t = 0.25 x fck1/2 (N/mm2) c
'

242.0 590.5 92.2 219978 0.42 1.12 safe

181.6 43.7 300.9 315024.38 0.96 1.12 safe

1.12 safe

Check for two way shear Critical section at distance 'd/2' from the face of column Length at critical section l o (mm) 845 Width at critical section b o (mm) 475 Depth available at section 185.8 Pressure coordinate at section (kN/m2) 449.9 Shear force V (kN) 359.3 2 0.92 Shear stress t= V / A (N/mm ) Permissible stress t = 0.25 x fck1/2 (N/mm2) c
'

894 524 193.0 589.2 607.8 1.08 1.12 safe

895 525 166.6 42.4 277.7 0.09 1.12 safe

1.12 safe

Check for development length Development length required (mm) Development length provided (mm)

752.2 850.0 safe

902.6 1200.0 safe

752.2 2350.0 safe

Page 1