CJ125 is a control and amplifier circuit for a wide range l-Sensor LSU4.x for the continuous regulation of l in combination with the sensor in the range of l = 0.65. (air) the application circuit of the CJ125 consists of the following parts: capacitor between [VCC] and [GND] to stabilize the supply voltage VCC Resistor between [IA] and [IP] to compensate parasitic effects of the lambda sensor Resistor

Uploaded by

sinasayedana
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
207 views7 pages

1267379259

CJ125 is a control and amplifier circuit for a wide range l-Sensor LSU4.x for the continuous regulation of l in combination with the sensor in the range of l = 0.65. (air) the application circuit of the CJ125 consists of the following parts: capacitor between [VCC] and [GND] to stabilize the supply voltage VCC Resistor between [IA] and [IP] to compensate parasitic effects of the lambda sensor Resistor

Uploaded by

sinasayedana
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 7

Automotive Electronics Product Information Lambda Probe Interface IC - CJ125

Customer benefits: Excellent system know-how Smart concepts for system safety Secured supply Long- term availability of manufacturing processes and products QS9000 and ISO/TS16949 certified

Features Currents and Voltages (box 1) Integrated circuit for continuous lambda regulation with Ri measurement Pump current control (boxes 2a to 2b) Pump current sense amplifier (boxes 3a to 3b) Lambda output amplifier (box 4) Virtual ground voltage source for sensor and pump current control (box 5) Nernst cell reference voltage source (box 6) Oscillator (box 7) Circuit for Ri or Rical measurement (boxes 8a to 8d) Diagnostic of sensor lines (box 9) Diagnostic of external heater (box 10) Serial-Peripheral-Interface (SPI; box 11) Programmable reference pumping currents (box 12) Suppression of Ri-measurement (box 13)

The integrated circuit CJ125 is a control and amplifier circuit for a wide range -Sensor LSU4.x for the continuous regulation of in combination with the sensor in the range of = 0.65... (air).

Block-/ functional diagram

Application circuit (only proposal!)

PIN configuration SOIC24

The application circuit of the CJ125 consists of the following parts: Capacitor between [VCC] and [GND] to stabilize the supply voltage VCC Capacitor between [UB] and [GND] to stabilize the supply voltage VUB Capacitor between [CF] and [GND] to filter the lambda signal Capacitor between [UA] and [GND] to stabilize lambda signal output Capacitor between [UN] and [GND] to stabilize nernst signal Capacitor between [/RST] and [GND] to stabilize reset signal Shunt between [IA] and [IP] for pump current sensing Resistor between [IA] and [UP] to compensate parasitic effects of the lambda sensor Resistor between [US] and [UP] to feed the nernst cell reference voltage into the pump current control circuit Resistor between [UP] and [UN] for leakage detection Resistor between [RF] and [CF] to filter the lambda signal Capacitor between [UR] and [GND] to stabilize the output signal for ADC Capacitor between [UN] and [GND] for filtering Resistor between [RM] and capacitor at [CM] for adjustment of Ri measurement current Capacitor between [CM] and resistance at [RM] for DC filtering Resistor between [RS] and [VM] for adjustment Resistor between [DIAHD] and Drain of the external heater Resistor and capacitor before [UN] for filtering

PLCC28

LQFP32

Pin description Pin


UB VCC, VCCSa) GND, GNDSb) VM US IP IA

Description
Power supply input (14V) Power supply input (5V) Ground Virtual ground of pump current control and of the LSU (0.5VCC) Nernst cell reference voltage (450mV) Inverting input of pump current amplifier (shunt voltage) Non inverting input of pump current amplifier and output of the pump current control Output of pump current amplifier (-> external filter) Input of lambda output amplifier (after external filter) Output of lambda output amplifier Non inverting input of pump current control Inverting input of pump current control respective in-/output for Ri-measurement (LSU)

Pin
RM CM RS UR DIAHG DIAHD SCK SI SO /SS /RST OSZ
a.)

Description
Output Ri-measurement current (DC) Input Ri-measurement current (AC, DC free) In-/output Ri-calibration measurement Output Ri-signal (analogous) Diagnosis input (gate of external transistor) Diagnosis input (drain of external transistor) Input SPI-clock (from C) Input serial data (SPI, from C) Output serial data (SPI, to C) Slave select (SPI, from C) Input Reset Rextern = 10k

RF CF UA UP UN

For hybrid version it is recommended to connect VVCS with the reference VCC for the ADC For hybrid version it is recommended to connect GNDS with the reference ground for the ADC

b.)

Maximum Ratings Parameter


Supply voltage UB Supply voltage VCC junction storage ambient for SOIC/PLCC for max 50h ambient for LQFP for max 50h

Condition

Symbol
VUB VVCC TJ TST TA

Min.
-0.3 -0.3 -40 -40 -40 -40

Max.
35 5.5 150 150 110 125 125 140 VVCC + 0.3

Unit
V V C C C C C C V

Temperature

Maximum allowed voltages valid for pins: RM, UP, US,RF, CF, UA, UR, DIAHG, DIAHD; SCK, SI, SO, /SS, /RST, OSZ

VX

-0.3

Allowed current Maximum allowed voltages, no destruction when ISO-pulses 3a,b are applied. Valid for board pins: RS, UN, VM, IA, IP, CM Offset between GND and GNDS Offset between VCC and VCCS ESD

ext. resistor 6.8 k

IDIAHD VX

-1 -0.3

10 28

mA V

VGND VVCC Human Body Model R=1.5k, C=100pF

-0.25 -0.25 -2

0.25 0.25 2

V V kV

Electrical Characteristics Parameter


Power Supply Power supply Operating range Current consumption Current consumption Pump current control Offset voltage Input current Input offset current

Condition
VGND = VGNDS VVCC = VVCCS

Symbol
VUB VVCC IVCC IVCCS

Min.
9 4.75

Max.
18 5.25 76 4 10 1 1 30 30 10 1 17.24 8.15 12

Unit
V V mA mA mV A A mA mA A A

Voff -40C Tj < 150C IUP, UN -40C Tj < 150C Ioff VUN < VUP; PA = 1; Output current source condition -IA 0.5V < VIA < VCC-0.5V VUN > VUP; PA = 1; Output current sink condition IA 0.6V < VIA < VCC-0.5V No output current PA = 0 IA Pump current sense amplifier (LA = 0: measurement mode; LA = 1: adjustment mode) Input current -40C Tj < 150C IIP Amplification SPI-bit VL = 1 A0 Amplification SPI-bit VL = 0 A0 CMRR-1 CMRR-1= VUA/ VIP VIP=VIA=1...4V Common mode rejection ratio 0.5V < VUA < VCC-0.5V | IUA | < 10A Output voltage swing | IUA | < 10A; LA = 0 VUA Output voltage adjustment IRF =0A; LA = 1 VFR/ VVCC VUA VUA=VUA (LA = 1) - VUA(LA = 0) Output error offset adjust VIP=VIA=VVM | IUA | < 10A Virtual ground voltage source Output current operating range IVM Output voltage ratio -IIA-1mA < IVM < -IIA +1mA VVM/ VVCC Nernst cell reference voltage source Output current operating range IUS Oscillator Frequency f external 10k Measurement current for Ri (RA = 0 measurement mode; RA =1 adjustment mode) Output resistor of push-pull-stage -1mA IRM 1mA R Ri amplifier Leakage current when switch is open ILEAK Amplification A0 Ron for a switch Ron Input voltage range at CM, UN and RS VRI Output voltage range VUR Zero point for output trace VUR/ VVCC Pump reference current programmable with SPI-bits Current range - IUn PRx; x = 0 to 3 Diagnosis of sensor lines Short circuit to ground VVM / VVCC Short circuit to Vbat VVM / VVCC Short circuit to ground VUN / VVCC Short circuit to Vbat VUN / VVCC Short circuit to ground VIA,IP Short circuit to Vbat VIA Diagnosis of external heater Low level VDIAHG High level VDIAHG Input current (no pull up!) - IDIAHG Short circuit to ground DIAHG = low IDIAHD Short circuit to Vbat DIAHG = high IDIAHD Open load DIAHG = low IDIAHD No failure DIAHG = high IDIAHD No failure DIAHG = low IDIAHD Filter time T=1/f tDIAG / T SPI Data rate Bit-frame Number of read / write commands Number of register

-10 -1 -1 10 10 -10 -1 16.62 7,82

mV/V

0.20 0.285 -3

VVCC -0.18 0.315 3

V mV

-IIA -2 0.48 -0.4 2.49 5 -500 15 2 0.06 VVCC 0.05 0 0.35 0.55 0.30 0.72 0.3 VVCC -0.3 0.7 VVCC -1 -1000 -100 -100 -1000 350 30 / 32

-IIA +2 0.52 0.4 3.51 200 500 16.3 200 VVCC -1.1 VVCC 0.2 0.063 150 0.45 0.65 0.40 0.88 1.5 VVCC + 2 0.3 VVCC VVCC + 0.3 1 -350 10 000 100 -350 10 000 32 / 32 2 16 6 4

mA

mA kHz nA V V

V V V V A A A A A A

Mbaud bit

SPI - Block schematic, register, RD / WR-commands with hec- code

Failure bitsa)
00 01 10 1 1d)
a)

Ext. heater
Short circuit to ground Open load Short circuit to Vbat No failure

Sensorb)
Short circuit to ground Low battery c) Short circuit to Vbat No failure

SPI Write Access

Only each failure of the sensor leads to a switch off of pump current and virtual ground b) Failure identification at UN must be enabled with ENSCUN c) Open load is not recognizable; bits used for low battery d) After RD_DIAG or if no failure is present; Failure bits will be restored if failure is still present

v: command valid/not valid; dc: dont care (-) x: 0 or 1; Z: tristate

SPI - Timing

SPI Read Access

Chipset
x Valves Relays Inductivities Resistors
_ +

Battery

CY320
Sensor Sensor System Supply C Supply Sensor Supply Watchdog Reset CAN Driver ISO Interface Sleep/Wake

C
e.g. Infineon TC1796

CJ945
x 18 Low Side Power Drivers 6x 6x 2x 4x 2A/70V 2A/45V 3A/45V 1A/45V x x x

Sensor
CAN ISO

8x e.g. LEDs
_ +

8 2
ISO

CY100
8x 10 Bit A/D 5V Small Signal Out ISO Interface

A/D RAM CAN Peripherals FLASH

Fela

Lamps

CK240
Ignition Drivers H-Bridge Concept

Fela

FLASH CY30
RPM

CF173
CAN Driver

CAN

CJ840
Direct Injection

SMD085
Pressure Sensor

CJ125
-Sensor Control

Contact
Robert Bosch GmbH Sales Semiconductors Postbox 13 42 72703 Reutlingen Germany Tel.: +49 7121 35-2979 Fax: +49 7121 35-2170 Robert Bosch Corporation Component Sales 38000 Hills Tech Drive Farmington Hills, MI 48331 USA Tel.: +1 248 876-7441 Fax: +1 248 848-2818 Robert Bosch K.K. Component Sales 9-1, Ushikubo 3-chome Tsuzuki-ku, Yokohama 224 Japan Tel.: +81 45 9 12-83 01 Fax: +81 45 9 12-95 73 Internet: www.bosch-semiconductors.de

E-Mail: [email protected]

04/2006 All rights reserved by Robert Bosch GmbH including the right to file industrial property rights Robert Bosch GmbH retains the sole powers of distribution, such as reproduction, copying and distribution. For any use of products outside the released application, specified environments or installation conditions no warranty shall apply and Bosch shall not be liable for such products or any damage caused by such products.