0% found this document useful (0 votes)
514 views

Netbiter WS200 User Manual

NetBiter WS200 is a Trademark of IntelliCom Innovation AB. All other trademarks or registered marks in this manual belong to their respective manufacturers.

Uploaded by

ahjohnston25
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
514 views

Netbiter WS200 User Manual

NetBiter WS200 is a Trademark of IntelliCom Innovation AB. All other trademarks or registered marks in this manual belong to their respective manufacturers.

Uploaded by

ahjohnston25
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 44

webSCADA WS200 GSM/GPRS

User Manual

ISFM-4405-0009

Revision 1.17

webSCADA WS200

Revision List
Revision 1.00 1.10 1.11 1.12 1.13 1.14 1.15 1.16 1.17 Date 07-11-26 08-11-21 08-12-17 08-12-23 09-01-19 09-04-22 09-10-30 10-03-29 10-06-10 Author Chapter Description First released version Layout and changes to match application version 3.30 b222 Added information about RS485 and alarms Backup/Firmware section is combined to System Added information for User Settings and System Editorial update Editorial update for 3.30.4 FW New graphical profile Warranty and support chapter updated JOAK/CHDA All CHDA CHDA CHDA CHDA CHDA CHDA CHDA MARA All

Preface
The data and illustrations found in this document are not binding. We reserve the right to modify our products in line with our policy of continuous product development. The information in this document is subject to change without notice and should not be considered a commitment by IntelliCom Innovation AB. IntelliCom Innovation AB assumes no responsibility for any errors that may appear in this document. The document uses following pictures to get the readers attention:
Symbol Description

Additional information for how to verify settings and how get the most out of NetBiter WS200

Note! Important information to avoid configurations that can cause problems and therefore should be read carefully.

Trademarks
NetBiter is a Trademark of IntelliCom Innovation AB. All other trademarks or registered marks in this manual belong to their respective manufacturers.

webSCADA WS200

Table of contents

About the NetBiter WS200 ..................................................................................................................... 7 1.1 General ............................................................................................................................................... 7 1.2 Mounting on DIN rail ........................................................................................................................... 8 1.3 Bottom connectors .............................................................................................................................. 8 1.3.1 Modbus RTU, RS-232 ................................................................................................................................ 8 1.3.2 Ethernet interface ..................................................................................................................................... 9 1.4 Top terminal block .............................................................................................................................. 9 1.4.1 Power supply connection .......................................................................................................................... 9 1.4.2 Digital inputs ............................................................................................................................................ 9 1.4.3 RS-485 interface ....................................................................................................................................... 9 1.4.4 RS-422 interface ....................................................................................................................................... 9 1.4.5 RS-232 Interface ..................................................................................................................................... 10 1.5 LED Indicators ..................................................................................................................................10

Getting started ........................................................................................................................................11 2.1 Configure the NetBiter WS200 IP-address .....................................................................................11 2.1.1 About the NetBiter Config utility ............................................................................................................ 11 2.1.2 Installation Procedure ............................................................................................................................ 11 2.1.3 Scanning for connected devices .............................................................................................................. 11 2.1.4 Changing IP settings ............................................................................................................................... 12

Web-page overview ................................................................................................................................12 3.1 Browser requirements .......................................................................................................................12

4 5

Log in .......................................................................................................................................................12 User interface ..........................................................................................................................................14 5.1 Menu overview ..................................................................................................................................14 5.2 Where to start ...................................................................................................................................14 5.2.1 Hardware and user setup ....................................................................................................................... 14 5.2.2 Present data and send logs/alarms ........................................................................................................ 14 5.2.3 Everyday use ........................................................................................................................................... 14 5.3 User levels ........................................................................................................................................14 5.4 About.................................................................................................................................................14

Setup ........................................................................................................................................................15 6.1 Users.................................................................................................................................................15 6.2 Modbus .............................................................................................................................................16 6.2.1 Modbus RTU/Modbus ASCII.................................................................................................................... 16 6.2.2 Modbus TCP ............................................................................................................................................ 16 6.3 16 6.4 Modem ..............................................................................................................................................17 6.4.1 Insert SIM card ........................................................................................................................................ 17 6.4.2 Modem status......................................................................................................................................... 17 6.4.3 Modem settings ...................................................................................................................................... 17 6.4.4 Dial up/GPRS setting............................................................................................................................... 17 6.4.5 Dial-in settings ........................................................................................................................................ 18 6.5 Regional ............................................................................................................................................19 6.5.1 Time and date ......................................................................................................................................... 19

webSCADA WS200
6.5.2 Decimal separator ................................................................................................................................... 19 6.5.3 Module information ................................................................................................................................ 19 6.6 E-Mail ................................................................................................................................................20 6.7 SNMP ................................................................................................................................................20 6.8 Webserver.........................................................................................................................................21 6.9 GPS ..................................................................................................................................................22 6.10 Ethernet (TCP/IP network settings) ..................................................................................................22 6.11 System ..............................................................................................................................................22 6.11.1 Backup settings ....................................................................................................................................... 22 6.11.2 Firmware ................................................................................................................................................. 23 6.11.3 Tools ........................................................................................................................................................ 24 6.11.4 NetBiter.net ............................................................................................................................................. 24 7 Configuration ..........................................................................................................................................25 7.1 Work flow ..........................................................................................................................................25 7.2 Template ...........................................................................................................................................25 7.2.1 Add, upload and edit template ............................................................................................................... 25 7.2.2 Edit .......................................................................................................................................................... 25 7.2.3 Template Group ................................................................................................................................... 25 7.2.4 Parameter ............................................................................................................................................... 26 7.3 Devices .............................................................................................................................................26 7.3.1 Add/edit device settings .......................................................................................................................... 26 7.3.2 Device specific alarms ............................................................................................................................. 26 7.4 Pages ................................................................................................................................................27 7.4.1 Add page ................................................................................................................................................. 27 7.4.2 Edit/delete page ...................................................................................................................................... 27 7.4.3 General page configuration .................................................................................................................... 27 7.4.4 Configuration .......................................................................................................................................... 28 7.4.5 Edit parameter ........................................................................................................................................ 28 7.5 Alarm .................................................................................................................................................28 7.5.1 Alarm Alarm settings ............................................................................................................................ 28 7.5.2 Alarm configuration ................................................................................................................................ 29 7.5.3 Parameter select ..................................................................................................................................... 29 7.5.4 Alarm trigger operation .......................................................................................................................... 29 7.5.5 Alarm properties ..................................................................................................................................... 30 7.6 Log ....................................................................................................................................................30 7.6.1 Log configuration .................................................................................................................................... 30 7.6.2 Log parameters ....................................................................................................................................... 31 7.6.3 Log Edit log parameter ......................................................................................................................... 31 7.6.4 Bindings ................................................................................................................................................... 31 7.6.5 Bindings - Add data binding .................................................................................................................... 31 8 Everyday use ...........................................................................................................................................32 8.1 View page .........................................................................................................................................32 8.2 Status ................................................................................................................................................32 8.3 Devices .............................................................................................................................................32 8.4 Alarm .................................................................................................................................................32 8.4.1 Alarm status ............................................................................................................................................ 32 8.4.2 Alarm history ........................................................................................................................................... 32 8.5 Log ....................................................................................................................................................33 8.5.1 View trend graph..................................................................................................................................... 33 8.5.2 Log ........................................................................................................................................................... 33 A Specifications..........................................................................................................................................35

webSCADA WS200
B C D Internal registers .....................................................................................................................................36 SNMP........................................................................................................................................................38 NetBiter.net..............................................................................................................................................39

webSCADA WS200

Warranty and support


To obtain fast and simple support for your NetBiter products, please use our Internet support service at http://www.intellicom.se/support. Here you will find the latest documentation, configuration utilities, drivers etc.

Product return
If you experience any problems with a NetBiter device and wish to have it repaired or exchanged, you will need to follow these steps: Obtain a Product Return Number, PRN, from http://support.intellicom.se. To get this number you will need to provide some information about the problem you have, contact information etc. Print the PRN Acknowledge side and send it to IntelliCom together with the product. Make sure the PRN is visible on the outside of the package, and that the delivery is pre-paid, otherwise the delivery would not be accepted by IntelliCom. Also provide evidence of original purchase. If the faulty product is covered by the 12-month warranty, IntelliCom will repair or exchange the unit and return it within three weeks. If the product is not covered by Warranty, IntelliCom will respond with a cost-estimation for repairing the unit.

Terminology
Term
TCP/IP

Extract

Description

Transmission Control Protocol/ TCP (Transmission Control Protocol) is a set of rules used along with the Internet Protocol Internet Protocol (IP) to send data in the form of message units between computers over the Internet. Hyper Text Transfer Protocol HTTP is a set of rules for exchanging files (text, graphic images, sound, video, and other multimedia files) on the Web. DHCP is a standard protocol that automates the process of configuring network hosts by allowing hosts to obtain IP addresses and configuration parameters A device that makes it possible to transfer data between networks of different kind, e.g. Modbus/RTU and Modbus/TCP. Describes a Modbus slave device, as a collection of groups and parameters. A Modbus slave unit that is connected to the NetBiter. Modbus register configured in the NetBiter.

HTTP

DHCP

Dynamic Host Configuration Protocol

Gateway

Template Device Parameter

webSCADA WS200

1 About the NetBiter WS200


1.1 General
The NetBiter WS200 acts as a bridge from Modbus TCP to Modbus RTU, making it possible for a Modbus TCP based controller to connect with Modbus RTU based devices. The NetBiter WS200 will handle alarm management, logging data as well as providing a built in web user interface for accessing data. Some WS200 features: Graphical user interface that is easy to work with. Support for device templates to allow easy and flexible management of configurations. Advanced modem handling, internal GSM/GPRS. Improved alarm handling, now with alarm history and SNMP support. Language support. Support for sending log-files with email. Support for the NetBiter.net portal. Auto detection of attached Modbus slave devices Support for GPS

Figure 1 Use of NetBiter WS200

NetBiter WS200 supports an RS-232 connection through a 9-pin DSUB or RS-485/RS422 (screw terminal). It also supports 10/100 Mbps Ethernet through a standard Ethernet connector (RJ-45). It can be configured via a user-friendly webinterface or by using the NetBiter Config utility (available at http://support.intellicom.se).

webSCADA WS200

1.2 Mounting on DIN rail


A Snap on B Snap off

1.3 Bottom connectors

Figure 2 Connectors on bottom view

1 Snap the NetBiter WS200 on to the DIN-rail (as described on picture A above).

Position 1 2

Description Serial interface 9-pin DSUB RS-232 Ethernet interface, RJ-45 10/100 Mbps

1.3.1 Modbus RTU, RS-232

The 9-pin DSUB, male connector on the NetBiter WS200 unit contains an RS-232 interface. This port can be used to connect to any equipment with an RS-232 interface.
Pin number 1 2 3 4 5 6 7 8 9 Function CD (Carrier Detect) Rx (Receive) Tx (Transmit) DTR (Data Terminal Ready) GND DSR (Data Set Ready) RTS (Request To Send) CTS (Clear To Send) RI (Ring Indicator)

Table 1 Description of 9 pin DSUB connector

webSCADA WS200

1.3.2 Ethernet interface

The voltage levels for the logic states are:


Logic state High Low Voltage level (DC) 10-24 V 0-2 V

Table 4 Voltage levels od digital input signals

The status of the inputs can be read as Internal Registers.


Figure 3 Top screw terminal

The Ethernet interface supports 10/100 Mbps, by using a standard RJ-45 connector.

The internal registers can be read from an external device if the gateway functionality is enabled. See section 6.2.2 on page 16 for more information.

1.4 Top terminal block


At the top of the NetBiter WS200 there is a screw terminal block that is used for power supply and communication interfaces. For power supply and digital input use minimum wire size 24AWG.

1.4.3 RS-485 interface


The following pins on the top terminal block are used for the RS-485 interface:
Pin number 13 14 17 Description RS-485 Line B RS-485 Line A Common

1.4.1 Power supply connection


The NetBiter WS200 can be powered by a 9-28V DC supply (Power requirement 3 W). The following pins on the top terminal block are used for power supply:
Pin number 23 24 Description Vin (Ground connection) Vin +

Table 5 RS-485 interface pins

1.4.4 RS-422 interface


The following pins on the top terminal block are used for the RS-422 interface:
Pin number 13 14 15 16 17 Description RS-422 Transmit B RS-422 Transmit A RS-422 Receive B RS-422 Receive A Common

Table 2 Power supply pins

1.4.2 Digital inputs


The digital inputs are opto-isolated and are found at the top terminal block with following pin numbers:
Pin number 20 21 22 Description Digital Input 2 + Digital Input 1 + Digital Input Common

Figure 4 Normal wiring diagram Modbus terminal A and B Table 6 RS-422 interface pins A B NetBiterWS200 A B Modbus device

Table 3 Digital input pins

The RS-485 and RS-422 interface cannot be used at the same time as the terminal block interfaced RS-232.

webSCADA WS200

1.4.5 RS-232 Interface


The following pins on the top terminal block are used for the RS-232 interface:
Pin number 17 18 19 Description Common RS-232 Transmit (Ouput) RS-232 Receive (Input)

1.5 LED Indicators

Table 7 RS-232 Interface pins Figure 5 LED position on front view

The RS-232 interface can not be used at the same time as the RS-485 and RS-422 interface.

The LED indicators are found on the NetBiter WS200 front view with following indications:
Name Module Status Colour Off Green Red Serial Link Status Flashing Green Flashing Red Red Ethernet Activity Ethernet Link Green Orange Flashing Green Off Function No power Module is running in normal mode During boot-up Serial Packet, receiving Serial Packet, transmitting During boot-up Ethernet Packet, receiving No Ethernet Link detected Ethernet network detected, 10 Mbps Ethernet network detected, 100 Mbps

Table 8 Description of LED indicators

10

webSCADA WS200

2 Getting started
2.1 Configure the NetBiter WS200 IP-address
2.1.1 About the NetBiter Config utility
The NetBiter Config utility is a PC-based configuration utility to set TCP/IP network settings in the NetBiter. This utility has the ability to scan the Ethernet network for connected NetBiter WS200 devices and let the user set IPaddress, net mask, gateway, DNS and hostname for each unit.

When the NetBiter Config utility is started, it will scan the Ethernet network for NetBiter WS200 devices. All detected devices will be presented in a list in the main window. If you want to force a new scan for devices, you can press the Scan button.
Column IP SN GW DHCP Version Type MAC Description IP address of the NetBiter WS200 Subnet mask Default gateway Dynamically assigned IP address On/Off Version of the application-software Product type Ethernet MAC address of the NetBiter WS200

2.1.2 Installation Procedure


There are two methods to install the NetBiter Config utility, either downloading it from the IntelliCom website or use the installation CD ROM. Using the CD ROM: Run Setup-NetBiterConfig.exe and follow the onscreen instructions. From website: Download the self-extracting installation package Setup-NetBiterConfig.exe from http://support.intellicom.se/ and run it.

Table 9 Description of NetBiter Config utility window

2.1.3 Scanning for connected devices

Figure 6 NetBiter Config Utility: Scan devices

First ensure that you have connected the NetBiter WS200 devices you want to install to the same Ethernet network as the PC is connected to. Use standard Ethernet cables, straight-through, to connect NetBiter WS200 to a hub or switch, and a cross-over cable when connecting directly to a PC. The Wink button is used to identify a NetBiter WS200 that is connected to the network. The Module status LED will start wink green/red.

11

webSCADA WS200

2.1.4 Changing IP settings


To change IP settings on a detected device, doubleclick on the device you want to configure in the list of devices. This will open up a dialog where you can enter the desired IP configuration. To obtain necessary information about IP address, subnet mask etc, please contact your network administrator. Default password for authentication of the new settings is admin and has to be entered to save changed made in NetBiter Config utility.

3 Web-page overview
3.1 Browser requirements
The web-pages are optimized for Internet Explorer version 6 or later and Mozilla Firefox version 2 or later. Other browsers can work as well, but the webpages might appear differently and some functionality can be limited. The browser must be JAVA enabled, to use pages with JAVA content (like the graph page). If it is not, please visit www.java.com to download a JAVA-plugin for your browser.

4 Log in
Open a web browser (Internet Explorer for example) and enter the IP address you have set on the NetBiter WS200 unit with the NetBiter Config utility. For example, if you entered the address 10.10.10.35 then you should enter the text below in the address field of the browser and press enter. http://10.10.10.35 Now you should see the login screen:
Figure 7 NetBiter Config Utility: Change IP settings

Do not select the DHCP unless you have a DHCP server available on the network.

Setting Host Name IP Address Subnet mask Gateway Primary DNS Secondary DNS

Description Here you can enter a hostname of your device. The NetBiter WS200 IP address. Mask network The default gateway in the network The primary Domain Name Server The primary Secondary Name Server (if it exists)

Figure 8 Login screen

Username: admin Default password: admin. The default password can be changed to something else (recommended) as described in section 6.1 on page 15.
If you have problems to log in and you are sure that your password is correct, make sure that Caps Lock is not enabled on your keyboard.

Table 10 NetBiter Config Utility network setting window

Pressing Set will cause the NetBiter WS200 to reboot and after that the new settings will be enabled.

12

webSCADA WS200 The picture below shows the welcome screen which is shown when you first log into the module.

Figure 9 Welcome screen

13

webSCADA WS200

5 User interface
5.1 Menu overview
The menu items have a layout to help users get the most out of the NetBiter WS200. The main menu has two workflow directions, one for setting up the NetBiter WS200 (from right to left), and one for using it as a SCADA interface (from left to right). When referring to a sub menu this document will use /, i.e. when referring to the sub menu Users, which is found under Setup, the following syntax will be used: Setup/Users. Depending on the user level the menu items will be different, see section 5.3 on page 14.

5.3 User levels


The menu items are accessible depending to the current users user level. The user level is set for each user that is setup for the NetBiter WS200.
User level Read Menu items showing, typical use Status, Devices, Alarm, Log, About Used for users that need to monitor data. Write As for Read Used for users that should be able to acknowledge alarms, clear logs, alarm history Admin As for Write + Configuration Used for users that can alter the configuration; add and change templates, devices, pages, alarms, log and bindings. Super admin As for Admin + Setup Used for users that setup communication interfaces, such as Modbus, modem, Email server, SNMP, Ethernet and NetBiter.net. Can do backup and update firmware and install patches.
Table 11 User level description

5.2 Where to start


5.2.1 Hardware and user setup
How to setup communication interfaces and users see section 0 on page 15.

5.2.2 Present data and send logs/alarms


How to setup user interface for presenting data and configure alarms and logs see section 7 on page 25.

5.4 About
This menu item shows a window with information about the firmware revision and MAC address for the NetBiter WS200. More detailed information can be found under Setup/System see section 6.10 on page 22.

5.2.3 Everyday use


How to monitor data, alarms and logs, see section 8 on page 32.

14

webSCADA WS200

6 Setup
The setup menu item is used to setup hardware interfaces and communications, as well as users, webserver and NetBiter.net. All basic settings to get the NetBiter WS200 run with attached devices. Workflow for the sub menu is from left to right.

User Level

The menu items are accessible depending on the current users user level, see section 5.3 on page 14 for more information. Users password. Only has to be given when adding a new user or when changing the password, which is done by checking the box Change password. When adding a user the password has to be repeated, as well as when changing it.

Password

6.1 Users
At this sub menu item users can be added to the system. Users available can receive e-mail, SMS depending on the configuration for the user. To Edit a users option click on the users name and
Repeat Password

Table 12 Users menu item description

Only user level Super Admin has access to add and edit users.

Modbus - The default password for authentication of the new settings is admin.

click save when ready.

Option User-ID Name E-mail Mobile

Description The users login name Full name of the user E-mail address for the user Mobile phone number. Is used to be able to send SMS to the user if SMS is enabled and the correct Alarm Class is set see section 7.5.5 on page 30. When adding an alarm it is given an Alarm Class. If the user should get the alarm the alarms corresponding Alarm Class has to be marked. A user can have several alarm classes, see section 7.5.5 on page 29. If this option is enabled the user will get the log as an e-mail attachment if it is enabled at the log configuration, see section 7.6.1 on page 30. Select the user interface language. There could be different languages set for different users. Every parameter in of the templates uploaded to NetBiter WS200 can be viewed using the main menu option Devices. If the user with user level admin or write can change parameters, and read on see parameters.

Alarm Class

Receive log files via E-mail

Language

Show Device browser in menu

15

webSCADA WS200

6.2 Modbus
6.2.1 Modbus RTU/Modbus ASCII
This sub menu item lets the user configure the Modbus communication interface. Make sure that the wiring is correct. The status page gives information about the Modbus connection, and can be useful as a trouble shooting tool when setting up the Modbus interface. See section 8.2 on page 32. The Modbus device has to be setup with a template and salve address, see section 7.1 on page 25.
Option Transmission mode Slave Response Timeout Description Set Modbus RTU or Modbus ASCII transmission mode [Default RTU]. The time that the NetBiter WS200 will wait for a response from a slave before Serial Timeout will occur [Default 1000]. Serial Timeout can be monitored at the Status page see section 8.2 on page 32. Electrical interface that is used. Make sure that the wiring is correct and connected to the interface: RS-485, see 1.4.3 on page 9. RS-422, see 1.4.4 on page 9. RS-232, see 1.4.5 on page 10. RS-232 (D-Sub), see 1.3.1 on page 8. [Default RS-485] Baudrate Character Format Parity Character format Stop bit Extra delay between messages Character delimiter Baudrat settinings. Can be 300-115 200 bps. [Default 9600] Parity settings; no, even or odd parity. [Default None] Number of stop bit, 1or 2 stop bit. [Default 1 stop bit] Time to delay between Modbus messages in milliseconds. [Default 0] Number of milliseconds between characters in a Modbus frame. Set to 0 to use Modbus standard 3.5 characters. [Default 0] If this option is Enabled, all writes to coils will be done with function code 15. (Useful if slaves do not support function code 05). If this option is Enabled, all writes to registers will be done with function code 16. (Useful if slaves do not support function code 06).

Table 13 Description of Modbus RTU/Modbus ASCII settings

6.2.2 Modbus TCP


Option Port number Description The port to use for Modbus TCP communication. [Default 502] If enabled the internal registers will be available at the slave address given in the Address-field. The internal registers are specified in appendix 0 on page 36 . Some of the registers can be used for pages, alarms and logs using the Internal Register as device. The queries sent to this Modbus address will not be sent to the Modbus RTU network, NetBiter WS200 will respond to these queries by itself.

Gateway Registers

Server Idle Timeout

Physical interface

If enabled the idle timeout in seconds for the Modbus TCP connection can be set. If there is no response within this time the connection will be closed. If disabled the connection will not timeout. [Default Enabled, 60]

IP Authentication

If enabled this feature makes it possible to configure the IP address that is allowed to connect to the gate way.

Table 14 Description of Modbus TCP settings

Use function code 15 when writing single bits(coils) Use function code 16 when writing single registers

16

webSCADA WS200

6.3 Modem
6.3.1 Insert SIM card 6.3.4 Dial up/GPRS setting
Settings used for NetBiter WS200 to communicate with Internet using a modem. Is used to send email, logs and alarms where there is no Ethernet connection available. If NetBiter.net is enabled and no Ethernet connection is available the Connection trigger has to be set to Always connected.
Option Connection trigger
Figure 10 Insert SIM card

Description Defines how the Netbiter WS200 should connect to Internet. When set to Alarm/Event it will make a connection when needed to send e-mail, alarm, log or other information that requires an Internet connection. An address to a host, IP address or server name, to send a ping packet which will keep the connection to Internet. This is used as a keep alive message. Sets the interval for the keep-alive message. Should be as long as possible to avoid unnecessary GPRS data traffic. GPRS gateway that is given by the SIM card operator. Phone number to dial to the Internet Service Provider, ISP. User name assigned by the ISP. Password assigned by the ISP

Open the SIM card holder using a pen, or something small, to push SIM card holder release button. Insert the SIM card in the SIM card holder and the holder into the NetBiter as shown in picture.

6.3.2 Modem status


On the status page the current status of the modem is displayed, see section 8.2 on page 32.

Host to ping

6.3.3
Option

Modem settings
Description If SIM card has PIN code security activated the pin code should be entered here followed by clicking test pin code, to save the PIN code. A window with information about the connected modem will show. If GSM/GPRS it will give information about Manufacturer, IMEI-number, PIN status and signal strength. There is information about the SIM code, which could be ready, if OK, or SIMPIN or SIMPUK when demanding user action. The PIN or PUK code is entered at Pin code when necessary. The SIM card has to be registered on a network to be able to work which status can viewed on the line Network status.

Ping timer

Pin code

Access Point Name (APN) Phone number

Modem info

User name Password


Table 16 Dial up/GPRS settings

Test SMS

If a GSM/GPRS modem is attached, enter a phone number to generate a test SMS to that number.

Table 15 Modem settings

17

webSCADA WS200

6.3.5

Dial-in settings

This section handles a dial in connection, i.e. when the user should be able to call the NetBiter WS200 using a modem. A network connection has to be set up on a PC where the phone number is the number of the SIM card used in the NetBiter WS200. The phone number must be data number (CSD). User name and password for the network connection should be those entered in this section.
Option Local IP address Description The IP address assigned to the Netbiter WS200. This IP number should be entered in the web browser after a connection is established. The IP address that will be assigned to the calling computer, the remote client. Must be the same sub net as Local IP number. User name used to establish a connection. Is required on the PC when creating a network connection. Password used to establish a connection. Is required on the PC when creating a network connection.

Remote IP address

User name

Password

Table 17 Dail-in settings

18

webSCADA WS200

6.4 Regional
The Regional page contains configuration for time and date, generic module information and also configuration for how the log file list separator and decimal symbol should be represented.

6.4.3 Module information


Option Site name Description A name for this NetBiter WS200 that is used when sending test SMS and test e-mail to identify which module that sent the message. The site name is shown left to the log out button in the user interface header. More information Notes for this NetBiter WS200. This information will be shown here only.

6.4.1 Time and date


Option Date Description Current date. Stored to a clock that will be battery backup up for maximum a week. Time Current time. Enter the actual time. Daylight saving and time zone are set separately. Stored to a clock that will be battery backup up for maximum a week. Time zone The time zone that is used. For time zones marked with * daylight saving will be used. Then time entered should be actual current time. The NetBiter WS200 will change time automatically. Network time protocol, NTP, is a server from where data can be read and used to set time and date. Requires an Internet connection. A server that support and can deliver NTP information. Could be an IP address or domain name Interval of how often the time and date should be synchronized with data from the server. When using GSM/GPRS the amount of data for every synchronization should be considered.

Table 20 Module information

Network time protocol

NTP server

Update interval

Table 18 Time and date

6.4.2
Option

Decimal separator
Description Sets the decimal separator and the separator character used for the csvlogfile. [Default Dot (.) and Comma(,)]

Decimal separator and log file value separator

Table 19 Decimal separator

19

webSCADA WS200

6.5 E-Mail
Option SMTP server Description Server that is used for sending e-mail. Could be entered as IP address or domain name. This is an SMTP server setting, and should be given by the Internet Service Provider, ISP. The port number is set to 25 by default for custom server. When using NetBiter.net services it is set to 2525. [default 25] If the server requires a login the type of method it set here. [default disabled] User name for the SMTP server Password for the SMTP server This is what will be shown in the FROM field of a the mail sent from the NetBiter WS200. The reply e-mail address This feature is used to test the SMTP settings. Enter an e-mail address and click send. A test mail will be sent to the address. Some e-mail servers may consider this test mail as junk.

6.6 SNMP
More information about sending SNMP trap functionality see appendix C on page 38.
Option SNMP manager Description IP address or name of the SNMP manager which should receive SNMP traps. Port number that the SNMP manager will listen to (to detect SNMP traps).

Port number

Port

Table 22 SNMP settings

SMTP Authentication

User name Password Sender

If domain name is used make sure that the DNS setting for the Ethernet connection is correct.

Reply path Send test E-mail

Table 21 E-mail settings

20

webSCADA WS200

6.7 Webserver
The webserver settings refer to the internal webserver of the Netbiter WS200.
Option Extra webserver port Description To connect to the Extra webserver port the URL should have a colon : followed by the new port number, i.e. http://10.10.10.30:8080 where 10.10.10.30 is the IP number or DNS address to the NetBiter WS200 and :8080 the new port. This feature is only used for the extra webserver port. When set to enable the NetBiter WS200 check if the browser support compressed pages, and if that is the case it will send compressed pages. This feature will increase the workload of the NetBiter WS200, why it is not enabled as default. There is an option to disable compression and the pages will be sent as normal web pages, which always is the case for the standard web server port 80. If it is set to force web pages will always send compressed regardless the support of the web browser. The information that a webbrowser supports compressed data could sometimes be removed when passing some firewall or proxy servers. This is true for the default setting for port 80 in Microsoft ISA servers. To ensure that compressed web pages are sent anyway the option force should be set. Most web-browsers support compressed data. Automatic logout time Auto update value and status This feature is only used for the extra webserver port. To limit the amount of data transferred and increase speed when using low bandwith, i.e. modem connection, the data and values could be set to be updated by clicking the refresh button only. This button will show at the upper right corner of the user interface. Figure 11 Refresh
button

Compression on web pages

Defines the time for how long a user can be inactive before the user is logged out due to session time out.

Table 23 Webserver settings

If domain name is used make sure that the DNS setting for the Ethernet connection is correct.

The webserver always listen to port 80. When using modem connection, compression on web pages will always be enabled and Auto update will always be disabled to improve response time, and the refresh button has to be clicked to update values and status.

21

webSCADA WS200

6.8 GPS
GPS that supports NMEA version 3 protocol sub message GGA and RMC can be used to upload information about position toNetBiter.net.
Option Enable GPS Physical interface Baudrate Upload distance Description Enable GPS functionality. Set the interface to use for a GPS. The baudrate that the GPS is set to. If the GPS register a movement of this distance an alarm messages is sent to NetBiter.net.

6.10 System
6.10.1 Backup settings
The backup consists of files the restore a module. Settings that are backed up are users, templates, devices, pages, alarms, log and settings for Modbus, modem e-mail server, GPS and NetBiter.net. Ethernet settings are not included in the backup, to prevent problems with identically IP address for modules.
Option Description All configurations except Ethernet settings will be backed up. A file with the extensions nbb, short for NetBiter Backup, will be created that can be saved on the local hard drive. A file of nbb, NetBiter Backup file, can be used to restore the setup and configuration for the NetBiter WS200.

Table 24 GPS settings

Backup Settings To Local Hard Drive

6.9 Ethernet (TCP/IP network settings)


The settings are the same as configured with NetBiter Config utility
Option DHCP Description If enabled the NetBiter WS200 will be assigned an IP address from the DHCP server on the net if there is one. See note below. A host name for the NetBiter WS200. IP address for NetBiter WS200. A subnet mask, which should be identical to the subnet of the network. Network gateway Domain name server to be able to access servers by domain Domain name server to be able to access servers by domain

Restore module from backup

Table 26 Backup

Host name IP Address Subnet mask

Gateway Primary DNS

Secondary DNS

Table 25 Ethernet (TCP/ netowork) settings

Do not select the DHCP option unless you have a DHCP server available on the network.

22

webSCADA WS200

6.10.2 Firmware
This information is helpful when contacting IntelliCom Support.
Option Description This is used to update firmware, files with extension nbu, or install patch, files with extension nbp, for the NetBiter WS200. Make sure to make a backup before starting to update the firmware, see section 6.10 on page 22. Latest firmware can be found at http://support .intellicom.se. When clicking update the NetBiter WS200 will start updating. Sometimes the web browser will not be able to display web pages. Just wait for some minutes and try to view the page again. The communication configuration for Ethernet, modem and NetBiter.net will not be affected which makes it possible to update firmware remotely. MAC address MAC address of the NetBiter WS200 Ethernet interface. Kernel version used in the NetBiter WS200. Application version of the NetBiter WS200. If there are patches installed in the system they will be displayed here with version and information about the patch.

Select an update file

Kernel version Application version Patches

Table 27 Firmware software

The latest firmware and kernel version can be found at http://support.intellicom.se. There is a link to this page at the bottom of the user interface.

23

webSCADA WS200

6.10.3 Tools
Option Get all log files Description Put all log files and system information in a tararcvhive. By clicking the reboot button the module will restart. By clicking this button the NetBiter WS200 will remove all settings and configurations and has to be setup and configured as a brand new NetBiter WS200.

6.10.4 NetBiter.net
NetBiter.net is a solution for remote management of NetBiter devices. The NetBiter is preconfigured to be able to use these services. More information about the NetBiter.net remote management service can be found at http://www.netbiter.net .
Option NetBiter.net service Description Enables the NetBiter.net remote management services. This NetBiter device ID Code to activate the NetBiter as valid device at NetBiter.net. The code entered by default. Enable alarms to be sent to NetBiter.net. Enable log files to be sent to NetBiter.net.

Restart module

Reset To Factory Default Setting

Table 28 System tools

Device ID Activation code

NetBiter WS200 with patches installed should be set to factory default using NetBiter Update to upload firmware.

Send Alarms Send log files


Table 29 NetBiter.net settings

When NetBiter.net is enabled the SMTP server will automatically be set to NetBiter.net with correct user name and password. The NetBiter.net services uses port 5222 for communication to the server.

24

webSCADA WS200

7 Configuration
The configuration menu item is used to configure the NetBiter WS200 to display data and log data as well as send alarm messages. Before any data can be read from a Modbus device and be used for presenting, alarms and logs the communication interface has to be setup, see section 0 on page 15.

7.2.1 Add, upload and edit template


To administrate templates there are some buttons for this in the user interface.
Button Edit Restore Description Edit template Used the over write a template with a template file that is uploaded. To download a template file that could be locally stored and uploaded to restore or add a template. Remove a template from the NetBiter WS200. Upload a template file and add it as a new device template. Adds a new empty template that has to be configured, which is done by clicking Edit after the template has been assigned a name.

Backup

7.1 Work flow


Every Modbus device must have a Template.
Delete

Every Modbus device has to be configured as a Device with a Modbus address. The device has to be assigned to a template. When a Modbus device has been configured it can be used for data presentation, alarms and logs.

Upload template

Add template

7.2 Template
A template describes what registers can be used and what type the register is. It also contains information about how presentation should be shown such as scaling, enumeration and read/write access for the user interface. There are ready to use templates for Modbus devices that can be downloaded from http://support.intellicom.se.

Table 30 Template add, upload and edit

7.2.2 Edit
A template is structured into groups of parameter to gain simplicity when building pages, adding alarms and logs. A parameter is a Modbus register with information about presentation, type etc. Several parameters can be grouped into one group. A template can be renamed using the button rename at the same row as the current template name.

7.2.3 Template Group


To add a new group click add group. There has to be at least one group in a template. The group can be renamed by clicking rename, and erased by clicking delete.

25

webSCADA WS200

7.2.4 Parameter
When adding a new parameter by clicking Add parameter an Edit parameter window will be open.
For more detailed information click the question mark at upper right corner of the Edit parameter window.
Option Name Type Address Datatype Description The name of the parameter Modbus register type Modbus register address Type of the data read. If it is signed, byte length and order. Scale the register value Offset the register value Mask a register value The register value can be shown as read only, read/write and write only. Values can be enumerated, i.e 0=off;1=on, to show values as text. Number of decimals that should be shown. Use to prevent user from writing a value outside a valid range.

By clicking add device the device can be manually setup.

7.3.1 Add/edit device settings


Option Name Template Modbus/TCP server IP address Description The name of the device. The template that should be used for this device. The IP address for the Modbus/TCP server. If it is a Modbus/RTU device It should be left blank. The port to connect to the Modbus/TCP server. Modbus default is 502. [Default 502] Modbus slave address
Table 32 Add/edit device settings

Modbus/TCP server port

The unique Modbus Address.

Scaling Offset Mask Presentation

7.3.2 Device specific alarms


If a template supports device specific alarms, preconfigured alarms can be added. The alarm condition is set in the template and cannot be changed. The set button is used to set all alarms for the complete alarm list or an alarm group. The set a single alarm the check box can be used. The clear button is used to clear all alarms for the device specific alarm list or for an alarm group. The drop down box to set alarm class can be used to set the same class for a group, or different alarm class for a single alarm, see section 7.5.5 on page 30 for more information about Alarm class.

Enumeration

Number of decimals Valid range

Table 31 Parameter settings

7.3 Devices
Every Modbus slave that is connected has to be added with a unique Modbus address. Every device has to be assigned a device template. Autodetect can be used to add devices. Every Modbus address will be scanned with the current Modbus communication serial interface settings. Every Modbus device connected has to have a unique address set before starting the auto detection. The scanning will scan one Modbus address after another, which could take some time to perform. The scanning will be displayed in the progress bar. If the templates uploaded support identification for Modbus devices the correct template will be assigned. If not the devices will be added and the user has to be assigned a template manually. 26

webSCADA WS200

7.4 Pages
Pages is used to show data for a user, and works as a user interface from where a user can interact with the Modbus slave devices connected to the NetBiter WS200. There can be a maximum of 30 pages added.

7.4.3
Option Picture

General page configuration


Description A picture can be uploaded that will be shown at the top of the user interface. Limitations for the picture file are stated on the page. Press upload to upload a picture, and clear to delete it from the system. Use of files will decrease the space for log files.

7.4.1 Add page


To create a new page click the add page button, type in a name and click ok.
Page name

7.4.2 Edit/delete page


To edit an existing page click edit in the page list. If the start page button is clicked the page will be the first page presented when a user log in. Click clear start page. To remove a page from the Netbiter WS200, click delete.
Set as start page Overview name

A name for the page. Could be used to describe the page contents. The overview name will be displayed as sub menu in the user interface and can be viewed by all users The advanced overview name will be displayed as sub menu in the user interface for user with admin user level see section 5.3 on page 14. If set a start page, this will be the first page shown when a user log in. To remove a page as start page go to the page configuration overview and click clear start page or click start page for another page.

Advanced overview name

Save settings

To store the settings made in this section save settings has to be clicked.

Table 33 General page configuration

27

webSCADA WS200

7.4.4 Configuration
When a page has been set up with general configuration it can be filled with parameters that exist in a template for the devices added to the NetBiter WS200. 20 Modbus parameters can be added for a page, and a page can have one overview and one advanced overview, see section 0 on page 27. The parameters are divided into two columns, left and right, with 10 parameters in each one. To add or edit a parameter click the edit button at the row for the parameter, see section 7.4.5 for options for the parameter. To delete a parameter click clear.

7.5 Alarm
7.5.1 Alarm Alarm settings
Option SMS Alarm Description Enable SMS alarm if a modem is configured, see section 0 on page 16. Users with correct alarm class and a mobile phone number will receive a SMS, see section 6.1 on page 15. Email Alarm Enable e-mail alarm if an SMTP server is configured, see section 6.5 on page 19. Users with correct alarm class and an e-mail address will receive an e-mail, see section 6.1 on page 15. SNMP Alarm Enable SNMP trap alarms if a SNMP manager is configured, see section 0 on page 20. If disabled all alarms have to be acknowledge. When an alarm condition is fulfilled it sends an alarm message. After the condition has been back to normal and is fulfilled again a new alarm message will be sent. If enabled the user has to acknowledge the alarm before a new alarm message is sent. Alarms can be acknowledged from NetBiter.net user interface if these services are enabled, see section 0 on page 24.
Table 35 Alarm settings

7.4.5 Edit parameter


Option Device Description Select the device that has the parameter that will be shown. Select the group that contains the parameter. Select the parameter that will be shown. This is the text that will be shown next to the parameter value. Template format can be overridden to show the parameter value in Hexadecimal or Binary format. If Default it will use the format configured in the template. The Modbus register value will be divided by this value before it is shown on the web pages, and multiplied before written to the Modbus device. It is better to use the scaling option in the template, which will include scaling for use with alarms and logging.
Table 34 Edit parameter

Manual alarm acknowledge

Group Parameter Description

Presentation format

Presentation scaling

28

webSCADA WS200

7.5.2 Alarm configuration


The alarm configuration section contains a list of all configured alarm parameters. The alarms can be reconfigured by clicking edit and the alarm parameter page with all options will be displayed. The delete button will remove the alarm parameter. To create a new alarm parameter click add alarm parameter. There can be a maximum of 64 alarm parameters configured, and the alarm poll time is approximately 20 seconds.

7.5.4 Alarm trigger operation


Option Description The trig condition, can be set to: For values: Greater than Less than Equal to Not equal to Change

Trig on

For Bit operations: Any Neither All

7.5.3 Parameter select


Option Description Select the device that has the parameter to be used for the alarm. Select the group that contains the parameter. Select the parameter that will be used for the alarm be presented.

Device

For the device: No response

Group Parameter

Where the value is number of consecutive time outs.

Value/Bit

Select if the value or bit representation field should be used to enter condition. Enter a decimal value. If scaling is set in the template, the value will be compared to the scaled value.

Table 36 Alarm parameter select

Value

Bit presentation

Use the checkbox to mark what bit that should be used. Marked checkbox represent a bit=1.

Table 37 Alarm trigger operation

29

webSCADA WS200

7.5.5 Alarm properties


Option Alarm Class Description The alarm class is used to sort which alarm to send to which user. The user can have one or more alarm class configured. If an alarm will be trigged an alarm message will be sent to all user that has the alarm class configured. Severity The alarms severity. Used to describe how critical the alarm is. For SNMP there is a severity class called Clear, which will be sent for an alarm that enters normal alarm condition. Description Text that is displayed in the alarm list view and alarm history, and is sent to the SNMP manager. The subject for alarm message sent by e-mail and/or SMS. The message body of the alarm message sent by email and/or SMS. The message length is limited to 70 characters for a SMS, why it could be a good practice to keep it to that length.
Table 38 Alarm properties

7.6 Log
The log can have 64 log parameters configured and will save samples to a csv-file. This file can be viewed in the built in trend graph page or downloaded to be analyzed, in e.g. Microsoft Excel or OpenOffice Calc. How to view and download the csv-file, see section 8.5 on page 32.

7.6.1 Log configuration


Option Estimated log time Description Gives estimation about the time before the log file is full. This is an estimation, and will depend on the configuration, i.e. number of pages and parameters configured. The number and size of pictures for the pages will also affect the log file size. If the log interval is set to a predefined time, this will show as the estimated log time. Log interval Defines the time interval for between the samples that is saved to the log file. The log could be circular, which will fill the log with data. When full it can be sent. A new file will be created and the old one is deleted. This will set the time when a log should be sent. If a time period is selected the log will be sent with this interval, e.g. at the same minute for every hour when At least every hour is chosen. If NetBiter.net is enabled the minute is different for each NetBiter WS200 to spread load of Ethernet traffic and server load. Send log files as E-mail attachment If a Send log interval is specified the log file is sent as an e-mail attachment to user that has configured this option, see section 6.1 on page 15.

Subject

Message

Log type

Maximum send log interval

Table 39 Log configuration

30

webSCADA WS200

7.6.2 Log parameters


The Log parameter section contains a list of all configured log parameters. The log parameter can be reconfigured by clicking edit and the Edit log entry page with all options will be displayed. The delete button will remove the log parameter. To create a new alarm parameter click add log parameter. There can be a maximum of 64 log parameters configured.

7.6.4 Bindings
With bindings a Modbus register can be copied to another.

7.6.5 Bindings - Add data binding


Option Source Device Description Select the device that has the parameter that will be copied. Select the group that contains the parameter. Select the parameter that will be copied. Select the device that has the parameter that will be copied to. Select the group that contains the parameter. Select the parameter that will be copied to. The interval for each copy

Source Group Source Parameter Destination Device

7.6.3 Log Edit log parameter


Option Device Description Select the device that has the parameter that will be logged. Select the group that contains the parameter. Select the parameter that will be logged. Stores the difference between the two last samples. As an example; a pulse counter is used. This counter increase the value for each received pulse. For delta logging this will result in: Counter 5 20 32 Description Logged value 5 15 12

Destination Group Destination Parameter Copy interval


Table 41 Add bindings

Group Parameter Delta logging

Description that is used on the trend graph page, see section 8.5.1 on page 33 and in the csv-file that can be downloaded.

Table 40 Edit log parameter

31

webSCADA WS200

8 Everyday use
When a NetBiter WS200 has been setup and configured it is ready for everyday use, to monitor data, send logs and alarms.

8.4.2 Alarm history


Every change for an alarm parameter is logged in Alarm history, with information of the value for the parameter that trigged the alarm and information about messages sent from the NetBiter WS200. There can be 100 entries in the alarm history list. If the list is full and a new alarm occurs the oldest alarm history entry will be deleted. If the Show occurrence button is clicked only the entries with type Occurred will show, which could be useful when analyzing alarms. The Clear History button will clear all alarm history.

8.1 View page


To view a page that has been configured use the dropdown box at the upper left corner of the user interface, select the page to display.

8.2 Status 8.3 Devices


The Devices menu item is a browser that can browse all parameter in a template for a device and show current values. The page will show a list of all available Modbus devices. A tree with all groups will show when expanding the tree. Open a group by clicking on the group name to see values for each parameter. The Internal Registers will also be available to browse.

8.4 Alarm
The alarm menu item keeps track of the alarm parameter configured, and is used to see current state of all alarms as well as an alarm history, where the alarm parameter condition changes can be monitored, and if alarm message has been sent correctly.

8.4.1 Alarm status


This is a list of all alarms. The status of the alarm can be Ok or Present. If the acknowledge is required the Acknowledge button will be active for alarms where the condition has been fulfilled. If all the alarm that have been present and need to be acknowledge at the same time click the button Acknowledge all at the bottom of the list. The lists default view is to show all present and not acknowledged alarms. To view all alarms click Show all. To show only present alarm again click Show active.

32

webSCADA WS200

8.5 Log
The log menu item is used for analyzing logged parameters. The log could be viewed in a trend graph and be downloaded as a csv-file.

8.5.2 Log
Option Description Download the log from the NetBiter WS200 to a local computer as a csv-file that can be analyzed in software like Microsoft Excel or OpenOffice Calc. The csv delimiter character can be set in the Regional page, see section 0 on page 19.

Download Log To Local Hard Drive

8.5.1 View trend graph


This feature requires that the user has JAVA Virtual Machine installed. By using a left click on the mouse, keep the button down and release it at the diagonal corner of a box the graph will zoom to that size. By right clicking and keeping the button down the graph can be moved by moving the mouse.
Button Description Scroll graph up Scroll graph down Scroll graph right Scroll graph left Reset view, view all Zoom in Zoom out
Table 42 Trend graph user interface

Clear Log File


Table 43 Handle csv log file

Will delete the log from the NetBiter WS200.

The first three (3) parameters will automatically be displayed in the graph by default. Parameters can be shown or hidden by clicking the box in front of the parameter name. When a parameter is shown the line color will have the same color as the box. To hide a line click the box and it will be grey.

33

webSCADA WS200

Appendices

34

webSCADA WS200

A Specifications
Ethernet connection 10Base-T or 100Base-TX (IEEE 802.3) RJ45 connector Serial interface GPRS Multislot Class 12 Quad band SMA Antenna connection SIM card, 3 V and 1.8 V Serial interface RS-232 300-115.200 bps. 9-pin DSUB connector RS-485/422 300-115.200 bps screw connector Power Supply Plastic housing: 9-24 VDC (3W) Temperature range Operating : Storage : -30 - 65 C -40 - 85 C
Figure 12 NetBiter with plastic housing

Humidity range 5-93% RH, non-condensing Cover material for plastic housing LEXAN 940, self-extinguishing acc. to UL94-V0 Mounting option Plastic housing: DIN rail (EN 50022) Certifications CE according to EN 61000-6-2:2005 and EN 61000-6-4:2001 UL 508 RoHS Compliant

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference, and 2. This device must accept any interference received, including interference that may cause undesired operation." "This equipment complies with FCC RF radiation exposure limits set forth for an uncontrolled environment. The antenna used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter." "This Class B digital apparatus complies with Canadian ICES-003. Cet appareil numrique de la classe B est conforme la norme NMB-003 du Canada.

35

webSCADA WS200

B Internal registers
Holding register
1 2 3 4

Name
Digital input 1 status Digital input 2 status Number Active Connections MB/TCP Number Active Internal Connections Serial Status (Modbus/TCP)

Values
0 or 1 0 or 1 0-10 0-10

Options

Comment
Read only Read only Read only Read only

5 6 7 8 9 10

Valid responses Serial timeouts CRC errors Input Buffer overruns Frame errors Exception responses Serial Status (Buffered messages)

0-65535 0-65535 0-65535 0-65535 0-65535 0-65535

Can be cleared Can be cleared Can be cleared Can be cleared Can be cleared Can be cleared

11 12 13 14 15 16

Valid responses Serial timeouts CRC errors Input Buffer overruns Frame errors Exception responses Serial Status (Internal requests and Webpages)

0-65535 0-65535 0-65535 0-65535 0-65535 0-65535

Can be cleared Can be cleared Can be cleared Can be cleared Can be cleared Can be cleared

17 18 19 20 21 22

Valid responses Serial timeouts CRC errors Input Buffer overruns Frame errors Exception responses Configuration Registers

0-65535 0-65535 0-65535 0-65535 0-65535 0-65535

Can be cleared Can be cleared Can be cleared Can be cleared Can be cleared Can be cleared

23 24

Modbus/TCP Port Gateway Modbus address

1-65535 (-1)-255 -1 0 - 255 Disabled Enabled

Default port number is 502

Default

25

Modbus/TCP idle timeout

0-65535 (seconds) 0 1 - 65525 Disabled Enabled

Default 60 seconds

26

Baudrate 2400 4800 9600 19200 38400 57600 115200 2400 bps. 4800 bps. 9600 bps. 19200 bps. 38400 bps. 57600 bps. 115200 bps. Default value

36

webSCADA WS200
Holding register
27

Name
Parity

Values
0-2 0 1 2

Options

Comment

No parity Even parity Odd parity

Default

28 29 30

Number of Stop bits Slave timeout time Physical interface

1-2 25-65535 (milliseconds) 0-2 0 1 2 EIA-485 (RJ12) EIA-232 (DSUB) EIA-232 (RJ12)

Default 1 stop bit Default 1000 ms.

Default

Authentication 31 Valid IP address 1 0-255 0 1-255 32 33 34 35 36 37 38 Valid IP address 2 Valid IP address 3 Valid IP address 4 Mask for Valid IP address 1 Mask for Valid IP address 2 Mask for Valid IP address 3 Mask for Valid IP address 4 0-255 0-255 0-255 0-255 0-255 0-255 0-255 Disabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Second byte of IP address Third byte of IP address Fourth byte of IP address First byte of mask Second byte of mask Third byte of mask Fourth byte of mask First byte of IP address IP address auth disabled

37

webSCADA WS200

C SNMP
If SNMP Alarms is enabled, see section 7.5.1 page 28, all alarms will be sent as SNMP traps to the host specified on the SNMP page, see section 6.6 on page 20. The OID is sent in the following format in numbers: .1.3.6.1.4.1.23312.1.1.2 [IP address][event] .1.3.6.1.4.1.23312.1.1.[trap_id][trap_data] where. 23312 is Intellicom enterprise ID 1.1 is products NetBiter webSCADA and where event: 1 = Alarm set 2 = Alarm cleared A trap id is divided into five messages with following trap data: #1 Alarm ID #2 Alarm descriptions #3 Class ID (1-10) #4 Class description #5 Alarm severity, where 0 = indeterminate 1 = critical 2 = major 3 = minor 4 = warning 5 = cleared See the pictures for example of SNMP trap sent an alarm to warning of high temperature from a NetBiter. To try out the SNMP functionality the software Trap Receiver could be used. This program can be found at http://www.trapreceiver.com. Please, check the license for the software. It could be used to examine a trap sent to a PC to better understand the SNMP functionality of the NetBiter webSCADA.

38

webSCADA WS200

D NetBiter.net
The web site www.NetBiter.net collects and stores data from remote equipment. Through the central server an authorized user can access the information at any time and from any location.. The NetBiter webSCADA devices connect to the central server to submit critical equipment data, such as logged parameter data and alarms. At the server an authorized user can view and manage this information. The only tool the user needs is a standard web browser. The use of one central location for all remote equipment simplifies the work for anyone dealing with remote installations. The NetBiter.net service provides the following functions: Administrate and maintain users, projects, remote field units and data. Storage of log files produced and sent by the NetBiter webSCADA field units. View logged data as trend graphs. Management of active alarms and alarm history (alarm notifications updates automatically on the server). View the physical location of remote equipment on a map. Etc

NetBiter.net features

Trending Store data log files at NetBiter.net and view trend graphs of selected parameter data. Analyze trends to detect early warning of malfunctioning equipment. To be proactive to problems saves time and money immediately as travels to sites can be dramatically reduced.

Positioning View the location of remote equipment on a map. Easy and improved planning of service routes saves time for any service organization. When an alarm occurs in equipment, that unit in the map will automatically be marked in red color.

39

webSCADA WS200 Management of users, projects One central place for management of users, remote equipment and critical information. Store important blue prints, pictures, templates and more.

Getting started To get started with NetBiter.net you need to have a NetBiter with NetBiter.net activation code, which is found in the package. Setup the NetBiter device as it is described in section 0 on page 24. For more information about this service, please go to www.netbiter.net/about. To use the NetBiter.net service you will need an activation code. If you do not have the activation code, please go to www.netbiter.net/activation.

40

41

42

43

IntelliCom Innovation AB Linjegatan 3D SE-302 50 Halmstad SWEDEN

Phone Fax email Web Support Twitter

+46 35 18 21 70 +46 35 18 21 99 [email protected] www.intellicom.se support.intellicom.se twitter.com/NetBiter

44

You might also like