0% found this document useful (0 votes)
42 views6 pages

Certificate of Visual Examination and Mpi: Location: Mcu Deck

This document is a certificate of visual examination and magnetic particle inspection (MPI) for a set of drilling bails. It was examined on August 30, 2011 by OGEH EMEDOH, who is qualified at SNT Level II for MPI, liquid penetrant, and ultrasonic testing. The inspection found no defects and deemed the bails fit for use with a strength working load of 500 tons. The certificate provides identification numbers and specifications for the bails.

Uploaded by

Michael Okwuwa
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
42 views6 pages

Certificate of Visual Examination and Mpi: Location: Mcu Deck

This document is a certificate of visual examination and magnetic particle inspection (MPI) for a set of drilling bails. It was examined on August 30, 2011 by OGEH EMEDOH, who is qualified at SNT Level II for MPI, liquid penetrant, and ultrasonic testing. The inspection found no defects and deemed the bails fit for use with a strength working load of 500 tons. The certificate provides identification numbers and specifications for the bails.

Uploaded by

Michael Okwuwa
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 6

JCI

JC International Limited

RC 413243

PPI

Plot 5 JC Street, Off Peter Odili Road, Trans Amadi, P.O Box. 6427 Trans Amadi Port Harcourt TEL: 234-084-489909, 08033108342, E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION AND MPI


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

48306
Identification Number Qty

18/08/11

OGEH EMEDOH
Description of Equipment

SNT LEVEL II MT, PT & UT

A SET OF DRILLING BAIL 5352 5353 1 A Set Of Drilling Bail . SWL: 350 Tons

Date of next Examination: 17-02-12

LOCATION: MCU DECK


SPECIFICATION : MPI METHOD:

BSEN ISO 9934-1:2001, API RP 8B


Wet Visible

TEST PROCEDURE: CONTRAST MEDIA: INDICATOR:

JOP-020 White Contrast Aid Black Magnetic Ink

PARTS EXAMINED: Stressed Area RESULTS: Fit for use Name and address of equipment owner: Transocean Support Services No defect as at the time of inspection

Address of premises where Test / Examination was held: Jack Ryan

We hereby certify that on 18/08/11 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use. Signature of Inspector: Conducting Examination Date: Name of Inspector: OGEH EMEDOH Conducting: Examination only

Revision No: 01

Doc No: JCIC-020

JCI

JC International Limited

RC 413243

PPI

Plot 5 JC Street, Off Peter Odili Road, Trans Amadi, P.O Box. 6427 Trans Amadi Port Harcourt TEL: 234-084-489909, 08033108342, E-mail: [email protected] Website: www.jcinternationalng.com

UPPER EYEEYE
3 "
3 16

DRILLING BAIL

LOWER EYE
2 "
31 32

5352

Dia 3 "
5 8

11 "
3 4

8"
1 4

5"
1 2

16ft

UPPER EYE
3 "

LOWER EYE
2 "
31 32

3 16

5353

Dia 3 "
5 8

11 "
3 4

8"
1 4

5"
1 2

16ft

5 "
7 32

9 "

3 8

5 "
7 32

9 "
3 8

2 "
7 8

2 "
7 8

JCI

JC International Limited

RC 413243

PPI

Plot 5 JC Street, Off Peter Odili Road, Trans Amadi, P.O Box. 6427 Trans Amadi Port Harcourt TEL: 234-084-489909, 08033108342, E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION AND MPI


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

48303
Identification Number Qty

31/08/11

OGEH EMEDOH
Description of Equipment

SNT LEVEL II MT, PT & UT

A SET OF DRILLING BAIL 1 Y18R Y18L A Set Of Drilling Bail . SWL: 750 Tons

Date of next Examination: 30-02-12

LOCATION: MCU DECK


SPECIFICATION : MPI METHOD:

BSEN ISO 9934-1:2001, API RP 8B


Wet Visible

TEST PROCEDURE: CONTRAST MEDIA: INDICATOR:

JOP-020 White Contrast Aid Black Magnetic Ink

PARTS EXAMINED: Stressed Area RESULTS: Fit for use Name and address of equipment owner: Transocean Support Services No defect as at the time of inspection

Address of premises where Test / Examination was held: Jack Ryan

We hereby certify that on 31/08/11 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use. Signature of Inspector: Conducting Examination Date: Name of Inspector: OGEH EMEDOH Conducting: Examination only

Revision No: 01

Doc No: JCIC-020

JCI

JC International Limited

RC 413243

PPI

Plot 5 JC Street, Off Peter Odili Road, Trans Amadi, P.O Box. 6427 Trans Amadi Port Harcourt TEL: 234-084-489909, 08033108342, E-mail: [email protected] Website: www.jcinternationalng.com

DRILLING BAIL LOWER EYE S/N 18R

UPPER EYE

6 "
3 16

6 "
3 16

"

6 "

3 16

10

3 8

7 "
5 16

14 "
9 16

14 "
15 16

7 "
5 16

15ft1"

LOWER EYE S/N 18L

UPPER EYE

6 "
3 16

6 "

3 16

"

6 "

3 16

10

7 "
5 16

14 "
3 4

15

7 "
5 16

15ft1"

10

3 16

3 8

"

10

3 16

"

JCI

JC International Limited

RC 413243

PPI

Plot 5 JC Street, Off Peter Odili Road, Trans Amadi, P.O Box. 6427 Trans Amadi Port Harcourt TEL: 234-084-489909, 08033108342, E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION AND MPI


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Test / Examination

Tester / Examiner

Qualifications

48308
Identification Number Qty

30/08/11

OGEH EMEDOH
Description of Equipment

SNT LEVEL II MT, PT & UT

A SET OF DRILLING BAIL JR 2390/1 JR 2390/2 1 A Set of Drilling Bail . SWL: 500 Tons

Date of next Examination: 29-02-12

LOCATION: MCU DECK


SPECIFICATION : MPI METHOD:

BSEN ISO 9934-1:2001, API RP 8B


Wet Visible

TEST PROCEDURE: CONTRAST MEDIA: INDICATOR:

JOP-020 White Contrast Aid Black Magnetic Ink

PARTS EXAMINED: Stressed Area RESULTS: Fit for use Name and address of equipment owner: Transocean Support Services No defect as at the time of inspection

Address of premises where Test / Examination was held: Jack Ryan

We hereby certify that on 30/08/11 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use. Signature of Inspector: Conducting Examination Date: Name of Inspector: OGEH EMEDOH Conducting: Test & Examination / Exam only

Revision No: 01

Doc No: JCIC-020

JCI

JC International Limited

RC 413243

PPI

Plot 5 JC Street, Off Peter Odili Road, Trans Amadi, P.O Box. 6427 Trans Amadi Port Harcourt TEL: 234-084-489909, 08033108342, E-mail: [email protected] Website: www.jcinternationalng.com

DRILLING BAIL UPPER EYE S/N JR 2390/1 LOWER EYE

3 "

4 "

9 "

3? "

3 4

6 "
1 8

12 "
3 16

10? "

3"

11.122FT = 3.3MTR

UPPER EYE

S/N JR 2390/2

LOWER EYE

4 "

3? "

3"

9"

6 "
1 8

12"

10? "

3"

11.122ft = 3.39MTRS

6 "
3 16

6"

9 16