NSF/ANSI 44
MODEL: Operating Temperature: Operating Pressure: Voltage: Rated Service Flow: Rated Softening Capacity: (Grains / Pounds of Salt) Max Flow Rate to Drain: Amount of High Capacity Resin: Rated Efficiency:
SA-PRO-E 48 Water Softener 34o120o F 25125 psi 110V 60 cycles 12.1 GPM @ 13 psi drop 31,200 @ 7.5; 41,900 @ 15.2; 47,600 @ 21.2 4.3 GPM 1.5 ft3 4,170 grains @ 7.5 lbs
MODEL: Operating Temperature: Operating Pressure: Voltage: Rated Service Flow: Rated Softening Capacity: (Grains / Pounds of Salt) Max Flow Rate to Drain: Amount of High Capacity Resin: Rated Efficiency:
SA-PRO-E 70 Water Softener 34o120o F 25125 psi 110V 60 cycles 15.5 GPM @ 15 psi drop 48,000 @ 11.5; 64,400 @ 23.3; 73,100 @ 32.5 4.6 GPM 3 2.3 ft 4,170 grains @ 11.5 lbs
**Observe all state and local plumbing codes. **The efficiency of the softener has been determined in accordance with NSF/ANSI 44 and is valid only at the stated salt dosage. **This softener conforms to NSF/ANSI 44 for the specifically claimed performance. Manufactured By: R&M Manufacturing 28 South 1550 West Lindon UT 84042-1617 (801) 785-5557 CAUTION: Do NOT use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system. pn: LBL-ELIM-48-CERT
**Observe all state and local plumbing codes. **The efficiency of the softener has been determined in accordance with NSF/ANSI 44 and is valid only at the stated salt dosage. **This softener conforms to NSF/ANSI 44 for the specifically claimed performance. Manufactured By: R&M Manufacturing 28 South 1550 West Lindon UT 84042-1617 (801) 785-5557 CAUTION: Do NOT use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system. pn: LBL-ELIM-70-CERT
MODEL: Operating Temperature: Operating Pressure: Voltage: Rated Service Flow: Rated Softening Capacity: (Grains / Pounds of Salt) Max Flow Rate to Drain: Amount of High Capacity Resin: Rated Efficiency:
SA-PRO-E 90 Water Softener 34o120o F 25125 psi 110V 60 cycles 18.0 GPM @ 15 psi drop 37,400 @ 8.8; 65,800 @ 25.3; 74,700 @ 35.3 4.1 GPM 3 2.5 ft 4,280 grains @ 8.8 lbs
**Observe all state and local plumbing codes. **The efficiency of the softener has been determined in accordance with NSF/ANSI 44 and is valid only at the stated salt dosage. **This softener conforms to NSF/ANSI 44 for the specifically claimed performance. Manufactured By: R&M Manufacturing 28 South 1550 West Lindon UT 84042-1617 (801) 785-5557 CAUTION: Do NOT use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system. pn: LBL-ELIM-90-CERT
Table of Contents
Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Location Selection Water Line Connection Drain Line Connection Brine Line Overflow Line Connection Placing Conditioner into Operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Electrical Connection ProFlow 460i Series Control Seings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Programming Time-of-Day Seing Hardness Seing Capacity Seing Calendar Override Seing Common Features. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Salt Dial Adjustment Guest Cycle Manual Regeneration Removing the Valve Assembly for Servicing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Controller Seing for Servicing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Preventive Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Injector Screw and Injector Water Meter Specifications: Control Valve AUV-268-460i . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Pressure Graphs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Identification of Control Valving . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Valve Disc Principle of Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Flow Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Replacement Parts AUV-1053832 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Disinfection of Water Conditioners. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Sodium or Calcium Hypochlorite
Professional Series | 3 |
Installation
All plumbing and electrical connections must conform to local codes. Inspect unit carefully for carrier shortage or shipping damage. This system is not intended to be used for treating water that is microbiologically unsafe or of unknown quality without adequate disinfection before or aer the system.
The most common bypass systems are the Autotrol Series 1265 bypass valve (1) and plumbed-in globe valves (2). Though both are similar in function, the Autotrol Series 1265 bypass offers simplicity and ease of operation.
In
Not in Bypass
Out
In
In Bypass
Out
Location Selection
1. 2. The distance between the unit and a drain should be as short as possible. If it is likely that supplementary water treatment equipment will be required, make certain adequate additional space is available. Since salt must be added periodically to the brine tank, the location should be easily accessible. Do not install any unit closer to a water heater than a total run of 10 feet (3 m) of piping between the outlet of the conditioner and the inlet to the heater. Water heaters can sometimes overheat to the extent they will transmit heat back down the cold pipe into the unit control valve. Hot water can severely damage the conditioner. A 10foot (3-m) total pipe run, including bends, elbows, etc., is a reasonable distance to help prevent this possibility. A positive way to prevent hot water flowing from heat source to the conditioner, in the event of a negative pressure situation, is to install a check valve in the so water piping from the conditioner. If a check valve is installed, make certain the water heating unit is equipped with a properly rated temperature and pressure safety relief valve. Also, be certain that local codes are not violated. Do not locate unit where it or its connections (including the drain and overflow lines) will ever be subjected to room temperatures under 34oF (1oC) or over 120oF (49oC). Do not install unit near acid or acid fumes. The use of resin cleaners in an unvented enclosure is not recommended. 3.
Water Conditioner Water Conditioner
3. 4.
2.
5.
6. 7.
| 4 | Professional Series
the boom of the loop is level with the drain line connection. This will provide an adequate siphon trap. 5. Where the drain empties into an overhead sewer line, a sink-type trap must be used.
IMPORTANT IMPORTANT: Never insert drain line into a drain, sewer line or trap. Always allow an air gap between the drain line and the wastewater to prevent the possibility of sewage being back-siphoned into the conditioner. Note: Standard commercial practices have been expressed here. Local codes may require changes to these suggestions.
Caution! Do NOT connect overflow and drainline. Brine tank overflow will occur.
Overflow
2. 3.
Place the conditioner into operation. a. With the water supply valve completely open, carefully advance the indicator knob COUNTERCLOCKWISE to the center of the BRINE REFILL position. Hold at this position until water starts to flow through the brine line into the brine tank. Do not run for more than one or two minutes. b. Advance the indicator knob COUNTERCLOCKWISE until it points to the center of the BRINE/SLOW RINSE position. c. With the conditioner in this position, check to see if water is being drawn from the brine tank. The water level in the brine tank will recede very slowly. Observe water level for at least three minutes. If the water level does not recede, or if it goes up, reference the Troubleshooting section. d. Advance the indicator knob COUNTERCLOCKWISE to the SERVICE position and run water from a nearby faucet until the water is clear and so.
Electrical Connection
100 VAC, 115 VAC, and 230 VAC units: Remove twist tie from the power cord and extend cord to its full length. Make sure power source matches the rating printed on the control. Be certain a wall switch does not control the outlet. 12 VAC: Connect the plug of the transformer (supplied) secondary cable to the mating socket at the rear or boom of the timer housing. Be certain the transformer is secure and is plugged into a power source of correct voltage that is not controlled by a wall switch.
IMPORTANT IMPORTANT: If opened too rapidly or too far, media may be lost. In the 1/4 open position, you should hear air escaping slowly from the drain line. c. When all of the air has been purged from the tank (water begins to flow steadily from the drain), open the main supply valve all the way. d. Allow water to run to drain until clear. e. Turn off water supply and let the unit stand for about five minutes. This will allow all trapped air to escape from the tank. 4, Add water to brine tank (initial fill). With a bucket or hose, add approximately 4 gallons (15 liters) of water to brine tank. If the tank has a salt platform above the boom of the tank, add water until the level is approximately 1 inch (25 mm) above the platform.
Ion Exchange
Cation resin is used to create the ion-exchange process wherein dissolved minerals are removed and replaced with sodium ions.
| 6 | Professional Series
Raised Tab
Jumper Indicator Knob Time-Set Button Timer Locking Pin Transformer Plug Receptable Spare Jumper
Programming
Plug the wall-mount transformer into a functioning electrical outlet that is not controlled by a switch. Plug the transformer into the transformer plug receptacle on the control. Open the access door by pushing the raised tab on the door toward the le while pulling the tab out (5).
Time-of-Day Setting
With the jumper on the set of pins next to the word TIME (6), set the time of day to the closest hour by pressing the black TIME SET buon. PM hours are indicated by a light next to the leers PM on the display window. Note: The use of a small needle-nose pliers will aid in moving the jumper. Note: The unit is factory set to regenerate at 2:00 a.m. If you prefer to have the unit regenerate at an earlier or later time, simply set the current time of day accordingly (e.g., to have the unit regenerate at 4:00 a.m.two hours laterset the clock two hours earlier than the actual time of day). Note: The Timer Locking Pin should always be horizontal (5) during operation. Professional Series | 7 |
Hardness Setting
Move the jumper to the set of pins next to the word HARDNESS (8). Press the black TIME SET buon until the hardness of the incoming water supply is displayed. The hardness range is from 1 to 99 grains per gallon. To change water hardness stated in parts per million (PPM) to grains per gallon (GPG) use this formula: ppm 17.1 = gpg
4.
Depress the black TIME SET buon. The numbers will roll from 0 to 15. Release the switch at the desired number of days for the calendar override. For example, releasing the switch at 10 would program a 10-day calendar override. Disconnect power. Place jumper back on TIME and reconnect power. The calendar override program is maintained during power outages by the NOVRAM circuitry. To remove the calendar override, follow the same steps above and program back to 0.
5. 6. 7. 8.
Figure 6
Figure 8
Figure 9
Capacity Setting
Move the jumper to the set of pins next to the word CAPACITY (9). Press the black TIME SET buon until the correct capacity value is displayed. The capacity range is 1 to 99 kilograins. Refer to the Suggested Salt Dial Seings table (3). Return the jumper to the top set of pins next to the word TIME and replace the access door. The jumper must NOT be le on any pins other than the top pair next to the word TIME. Otherwise, the unit may show a blank display. Note: A spare jumper is located on the boom set of pins. In the event that the hardness or capacity seing must be changed, simply follow the appropriate steps described above.
Common Features
Salt Dial Adjustment
These models may be adjusted to produce maximum to minimum conditioning capacities by seing the salt dial, which controls the amount of salt used per regeneration. When desired, the minimum seing may be used on installations if the frequency of regeneration is increased to compensate for lower regenerated conditioning capacity. The installing dealer will set the unit for proper salt usage. Further adjustments are needed only if the hardness of the water supply changes or if water use changes dramatically. Capacity will need to be adjusted accordingly. To adjust salt dosage, insert a small screwdriver into the white indicator knob and move pointer to proper salt seing (Figure 10). Note: To convert the salt seings from English to metric, divide by 2.2 (e.g., 12 pounds 2.2 = 5.5 kg of salt).
Indicator Knob
Note: System comes pre-programmed with default hardness, capacity and corresponding salt seings. Refer to table 1 for default seings.
| 8 | Professional Series
Model 48 70 90
Capacity Default Seing Salt Seing 31,200 gr 48,000 gr 37,400 gr 7.5 lbs 11.5 lbs 8.8 lbs
Model 48 70 90
Max Flow Pressure Drop @ Rate Max Flow 12.1 gpm 15.5 gpm 18.0 gpm 13.0 psi 15.0 psi 15.0 psi
Max Flow to Drain (Regeneration) 2.5 gpm 3.5 gpm 4.0 gpm
Efficiency Ratings Tot. Gr. Recovrd 31,200 gr 48,000 gr 37,400 gr Gr. Recovrd p/ Salt lb 4,160.0 gr 4,170.0 gr 4,200.0 gr HighEff. Salt Seing 7.5 lbs 11.5 lbs 8.8 lbs Tot. Gr. Recovrd 41,900 gr 64,400 gr 65,800 gr Gr. Recovrd p/ Salt lb 2,756.6 gr 2,763.9 gr 2,600.8 gr MidEff. Salt Seing 15.2 lbs 23.3 lbs 25.3 lbs Tot. Gr. Recovrd 47,600 gr 73,100 gr 74,700 gr Gr. Recovrd p/ Salt lb 2,245.3 gr 2,249.2 gr 2,116.1 gr LowEff. Salt Seing 21.2 lbs 32.5 lbs* 35.3 lbs*
Model 48 70 90
Table 3: Efficiency salt seings * Extra salt cam: divide the suggested seing by 2 to accomplish salt seing. Note: Use any good grade rock salt (NaCl) to obtain rated capacities.
The amount of salt placed in the brine tank has nothing to do with the amount of salt used during the regeneration cycle. Water will dissolve and absorb salt only until it becomes saturated. A given amount of brine (saltsaturated water) contains a specific amount of salt. The salt dial controls the amount of brine used during the regeneration cycle (e.g., when set at 15 pounds (6.8 kg) the amount of brine the conditioner will use for each regeneration will contain 15 pounds (6.8 kg) of salt, etc.) Never let the amount of salt in the brine tank be lower than the normal liquid level. Do not overload the brine tank with salt.
Manual Regeneration
Electricity is used only to run the control and to rotate the camsha. All other functions are operated by water pressure. Therefore, in the event of a power outage, all the regeneration positions may be dialed manually by depressing the indicator knob and turning COUNTERCLOCKWISE ( and ). The following cycle times should be used for proper regeneration: BACKWASH14 minutes BRINE/SLOW RINSE52 minutes FAST RINSE/REFILL10 minutes PURGE6 minutes Do not exceed 10 minutes for the FAST RINSE/REFILL cycle as this will cause excessive salt usage during the next regeneration and possibly a salt residue in the soened water.
Guest Cycle
When abnormally high water usage exhausts your water conditioners capacity ahead of schedule, an extra regeneration can be achieved. Depress the indicator knob on the 440i (5) with a wide-blade screwdriver and turn COUNTERCLOCKWISE to START to initiate a regeneration. For the 460i, simply depress the indicator knob (5). It will take a few minutes for regeneration to start. A normal regeneration will take approximately two hours.
Soeners are WQA tested and certified according to NSF / ANSI 44 Standard.
Professional Series | 9 |
Indicator Arrow
4.
5. 6.
Figure 12: Top-down view of valve 4. Remove the camsha by carefully pushing the securing tab, located at the rear of the camsha, away from the camsha until the tab disengages from the camsha. Push the back of the camsha down and out to the inlet side of the valve (Figure 13).
Figure 13: Removing the camsha 5. 6. 7. Disengage the front of the camsha from the output gear of the control. Remove the timer locking pin and li the control straight up and off of the valve. To reinstall the camsha and control, reverse the above procedures.
| 10 | Professional Series
Preventive Maintenance
Injector Screen and Injector
Inspect and clean brine tank and screen filter on end of brine pickup tube once a year or when sediment appears in the boom of the brine tank. Clean injector screen and injector once a year: 1. 2. 3. 4. 5. 6. 7. 8. 9. Unplug the wall-mount transformer. Shut off water supply or put bypass valve(s) into bypass position. Relieve system pressure by opening valve No. 7 (at rear) with a screwdriver (Figure 11). Using a screwdriver, remove injector screen and injector cap (Figure 14). Clean screen using a fine brush. Flush until clean. Using a needle-nose pliers, pull injector straight out. Flush water into the injector screen recess of the valve body to flush debris out through the injector recess. Clean and flush the injector. Lubricate the O-rings on the injector, injector cap and injector screen with silicone lubricant only!
3. 4.
5.
10. Reinstall the injector, injector cap and injector screen. IMPORTANT IMPORTANT: Do not overtighten the plastic cap. Seat the cap lightly into position. Overtightening may cause breakage of the plastic cap that may not be immediately evident. 11. Plug the wall-mount transformer into outlet; reset clock if necessary. 12. Slowly open water supply valve or return bypass valve(s) to the service position. 6.
7. 8. 9.
To check for proper meter operation, open a downstream faucet and observe the water flow indication on the control display.
*RoVer is a trademark of Hach Chemical Company.
Professional Series | 11 |
Hydrostatic Test Pressure. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 300 psi (20.69 bar) Working Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20-125 psi (1.38 - 8.62 bar) Standard Electrical Rating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115V 60 Hz Optional Electrical Rating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115V 50 Hz, 230V 50 Hz, 200V 60 Hz, 24V 60 Hz, 24V 50 Hz, 100V 60 Hz, 100V 50 Hz, 12V 50 Hz/transformer, 12V 60 Hz/transformer Electrical Cord (standard rating) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60 inch (1.5 m) 3-wire with plug Pressure Tank Thread. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 1/2 inch-8 male Riser Pipe Diameter Required . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.3 inch OD (26.7 mm) Riser Pipe Length . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1/8 1/8 inches (31.8 mm) higher than the top of mineral tank Standard Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-inch (25.4-mm) copper tube adapters Optional Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3/4-inch, 22-mm, and 28-mm copper tube adapters 1 1/4-inch copper 3/4-inch, 1-inch, 25-mm CPVC tube adapters Brine Line Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3/8-inch NPT male Drain Line Connection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3/4-inch NPT male Optional Bypass Valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Rotating handles, full 1-inch porting, reinforced Noryl Control Module, Tank Adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Reinforced Noryl Rubber Goods . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Compounded for cold water service Program Clock (Timer). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 460i: Available in English Brine Refill Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 to 10 lbs (0.45 to 4.5 kg) of salt or 3 to 19 lbs (1.4 to 8.6 kg) of salt Injector Size A White . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Nozzle 042-inch (1.1-mm) diameter, Throat .089-inch (2.3-mm) diameter Injector Size B Blue. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Nozzle .052-inch (1.3-mm) diameter, Throat .099-inch (2.5-mm) diameter Injector Size C Red . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Nozzle .059-inch (1.5-mm) diameter, Throat .099-inch (2.5-mm) diameter Injector Size D Green . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Nozzle .071-inch (1.8-mm) diameter, Throat .147-inch (3.7-mm) diameter Internal Backwash Controllers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7- through 14-inch (17.8- though 35.6-cm) diameter media tanks All sizes to flow 4.5 gpm/sq ft (183 L/m/m2) of bed area. For tank sizes above 14 inches in diameter, use an external flow control.
| 12 | Professional Series
Flow* (lpm) 9.5 13.2 * Approximate flow rates at 60 psi (4.14 bar).
Professional Series | 13 |
Rinse Drain Valve (6) Outlet Valve (4) Bypass Valve (2) Valve Seat
Flow Diagrams
Service Position Backwash Position
| 14 | Professional Series
Purge Position
Professional Series | 15 |
14
10 16 15 3 6 7
13 9 8
12
6
3
14
12
Parts List
Code
1
Part #
AUV-1053832
Description
Control Valve (Complete) Valve Assembly, w/o Flow Controls (460i) Camshaft: (all models) Extra Salt Cam (for model 90 only) Timer Locking Pin Drain Control Assembly No. 10 (2.5 gpm; 9.5 Lpm) No. 12 (3.5 gpm; 13.2 Lpm) No. 13 (4.0 gpm; 15.2 Lpm) Ball, Flow Control Injector Assembly: A Injector - White B Injector - Blue C Injector - Red D Injector - Green Injector Cap Assembly A Cap B Cap C Cap D Cap
19
Qty
1
Code
8
Part #
<see below> AVP-1034261 AVP-1034263
Description
Brine Refill Control (460i) 1 to 10 Pounds Salt 3 to 19 Pounds Salt Ball, Flow Control Drain Fitting Elbow (3/4 hose barbed) Screen/Cap Assembly O-Ring Tank Ring Plumbing Adapter Kits: Turbine Assembly (460i only) Meter Spring, Flapper Valve Valve Disc Kit Standard Severe Service Cam Shaft Securing Clip I-Lid Cover
Qty
1
2a 2b** 3 4
1 1 1 1
9 10 11 12 13 14
1 1 1 1 1
5 6
1 1
1 1 1
19* AVP-1000811 Transformer * Not Shown ** Soft water refill is not available with the extra salt cam.
| 16 | Professional Series
3 7 9
10
14
13
6 11 15 12 Code #6: DST-1021-E: High-Flow Distributor Size 48, 70, and 90 (NSF-44) Code #4: Eliminator Cap Number Code 1 JKT-1165 JKT-1095 JKT-1220 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Pro-E 48 JKT-1115 10x44" PRO-E 70 JKT-1180 12x48" Code #5: Jacket Numbers Pro-E 90 JKT-1233 14x47" Part # AUV-1053832 AVP-1000062 DST-2001 See options See options DST-1021-E MDA-1000 BTC-1210 BTC-1000 BTC-1114 BTC-1306 BTC-1037 BTC-1033 BTC-1036 MTK-SP-1044 MTK-SP-1248 MTK-SP-1447 Description 268/460i Meter I-Lid Cover, 255, 268 Top Distributor 8
48 Qty 1 1 1
70 Qty 1 1 1
90 Qty 1 1 1
See cap options. Code #4 See jacket options. Code #5 See drawing Code #6 HCR Cation Resin BT 1840 Blk 2 PC Overflow Set Brine Well 4x36 Slot Cap 4" Air Check, 3/8" 474 Brine Valve 3/8" 474 Float Tank: 10"x44" Tank: 12"x48" Tank: 14"x47"
78 lbs 119 lbs 130 lbs
1 1 1 2 1 1 1 1
1 1 1 2 1 1 1 1
1 1 1 2 1 1 1 1
*Note: Drawing above is based on model 48. Larger models (70 and 90) increase case size respectively as seen at left.
Professional Series | 17 |
460i Control
Bypass Kit
BP-A-1040930
Code #2
Code 2 3 * * *
Description 460i Control 1265 Bypass (see table at right) Transformer (460i): Transformer Extension Cord 15 feet (4.6 m) Y-Splitter (run 2 units from 1 transformer)
Bypass Kit 3/4" Copper Tail Kit 1" Copper Tail Kit 1 1/4" Copper Tail Kit 3/4" CPVC Tail Kit 1" CPVC Tail Kit
*Not shown.
| 18 | Professional Series
Troubleshooting
The technology upon which the control valve is based is well established and proven in service over many years. However, should a problem or question arise regarding the operation of the system, the control can very easily be serviced. For parts mentioned, refer to exploded views in the Replacement Parts section of this manual. IMPORTANT IMPORTANT: Service procedures that require the water pressure to be removed from the system are marked with
a aer the possible cause. To remove water pressure from the system, put the bypass valve or three-valve bypass into the bypass position and open the backwash drain valve (the seventh valve back from the control) with a screwdriver. Restore system water pressure when the service work is completed. The problems outlined below are the most common occurances of problems. If you are unable to solve your problem with this manual, contact the manufacturer.
Possible Cause
Low water pressure. Restricted drain line. Injector plugged Injector defective Valve (2 and/or 4) not closed.
Solution
Set pump to maintain 30 psi at conditioner. Remove restriction. Lean injector and screen. Replace injector. Remove foreign matter from disc and check disc for closing by pushing in on stem. Replace if needed. Manually operate valve stem to flush away obstruction. Remove variable salt controller to clean. Flush out foreign matter by holding disc open and manually operating valve stem. Check all connections in brine line for leaks. Refer to instructions. Correct setting. Remove variable salt controller and flush out foreign matter. Manually position control to brine draw to clean controller (after so doing, position control to purge to remove brine from tank). Replace controller. Set pump to maintain 30 psi at conditioner. Replace both injector and injector cap. Check for power. Add salt. Clean injector. Flush with water. Replace with correct size controller. Remove controller and ball. Flush with water. Manually operate valve stem to flush away obstruction. Replace spring. Repeat regeneration making certain that the correct salt dosage is set. Replace O-ring. Replace O-ring.
Brine valve (1) being held open. Uncontrolled brine refill flow rate Valve (3 or 4) not closed during brine draw causing refill. Air leak in brine line.
System using more or less salt than salt control is set for.
Defective controller. Intermittent or irregular brine draw. Low water pressure. Defective injector No conditioned water after regeneration. Unit did not regenerate. No salt in brine tank. Plugged injector Control backwashes at excessively low or high rate. Flowing or dripping water at drain or brine line after regeneration. Hard water leakage during service. Incorrect backwash controller used. Foreign matter affecting controller operation Drain valve (5 or 6) or brine valve (1) held open by foreign matter or particle. Valve stem return spring on top plate weak. Improper regeneration. Leaking of bypass valve O-ring around riser tube damaged This procedure requires removal of water pressure from the system.
Professional Series | 19 |
Possible Cause
Transformer cord unplugged. No electric power at outlet. Defective transformer. Defective circuit board.
Solution
Connect power. Repair outlet or use working outlet. Replace transformer. Replace timer. Use outlet not controlled by switch. Replace timer with one of correct voltage and frequency (Hz). Reset clock. Replace timer. Disconnect power to unit. Restore power and reset time of day Replace timer. Shift bypass valve to not-in-bypass position. Fully insert probe into meter housing. Remove meter housing, free up turbine and flush with clean water. Do not disassemble turbine from meter housing. Turbine should spin freely. If not, replace meter Replace timer. Replace timer. Reset clock to correct time of day. Reset clock to correct time of day. Replace timer. Replace timer. Repair outlet or use working outlet. Replace timer. Replace timer. Check all junction points and make appropriate corrections. Remove foreign object obstruction from valve discs or camshaft. Install pressure regulator Replace timer. Replace timer. Replace timer.
Time display continues to advance. Time display shows something other than time of day. No water flow display when water is flowing.
Defective time set switch. Electrical interference. Defective circuit board. Bypass valve in bypass. Meter probe disconnected or not fully connected to meter housing. Restricted meter turbine rotation due to foreign matter in meter.
Defective meter probe. Defective circuit board. Control regenerates at wrong time of day. Timer stalled in regeneration cycle. Power outages. Clock set incorrectly. Motor dead. Motor runs backward. No electric power at outlet. Broken gear. Defective switch. Air leak in brine connections. Binding of camshaft. Water pressure greater than 125 psi during regeneration. Defective circuit board. Defective switch. This procedure requires removal of water pressure from the system. Continuous regeneration. Camshaft does not stop at the end of regeneration. Broken switch activator on gear.
| 20 | Professional Series
Possible Cause
Electric cord unplugged. No electric power at outlet. Defective motor. Broken gear. Binding in gear train. Defective switch.
Solution
Connect power. Repair outlet or use working outlet. Replace timer. Replace timer. Replace timer. Replace timer. Same as Item 5. Replace timer. Set to correct values. See Programming section. Repeat regeneration, making certain that correct salt dosage is used. Use resin cleaner. See Note 1. Set salt control to proper level. See Salt Setting chart. Set to correct values. See Programming section. Set hardness to new value. See Programming section. Remove meter housing, free us turbine and flush with clean water. DO NOT DISASSEMBLE TURBINE FROM METER HOUSING. Turbine should spin freely, if not, replace meter Repair leaky plumbing and/or fixtures
Control will not regenerate automatically but will regenerate when button is pressed.
If water flow display is not operative, refer to Item 5 Defective circuit board. Incorrect hardness and capacity settings.
Improper regeneration. Fouled softener resin. Incorrect salt setting. Incorrect harness or capacity settings. Water hardness has increased. Restricted meter turbine rotation due to foreign material in meter housing.
Excessive water usage below 1/5 gallon per minute. This procedure requires removal of water pressure from the system. Note: 1: Use of resin cleaners in an unvented enclosure is not recommended.
Professional Series | 21 |
1. Dosage a. Polystyrene resin: 1.2 fluid ounces per cubic foot. b. Non-resinous exchangers: 0.8 fluid ounce per cubic foot. 2. Brine tank conditioners a. Backwash the conditioner and add the required amount of hypochlorite solution to the brine well of the brine tank. (The brine tank should have water in it to permit the solution to be carried into the conditioner.) b. Proceed with the normal regeneration. This will flush and condition the unit for use.
Calcium Hypochlorite Calcium hypochlorite, 70% available chlorine, is available in several forms including tablets and granules. These solid materials may be used directly without dissolving before use. 1. Dosage a. Two grains (approximately 0.1 ounce) per cubic foot. Brine tank conditioners a. Backwash the conditioner and add the required amount of hypochlorite to the brine well of the brine tank. (The brine tank should have water in it to permit the chlorine solution to be carried into the conditioner.) b. Proceed with the normal regeneration. This will flush and condition the unit for use.
2.
Caution: Do NOT install on water that is microbiologically unsafe, or of unknown quality without adequate disinfection before or aer the system.
| 22 | Professional Series
R&M Water Group 28 South 1550 West Lindon, Utah 84042 P: (801) 785-5557 F: (801) 785-7823 www.eproflow.com
2006 R&M Water Group. All rights reserved. rev: Feb 2006 | pn: L-R-ProFlow-OM