COMPRESSORS

Collection of Datasheets

Compressors for R134a


220-240V 50Hz & 60Hz

R E F R I G E R AT I O N A N D A I R C O N D I T I O N I N G

R12 R22 R502

Standard Compressors

High Energy-optimized
Compressors

P-Series
PL20F (50Hz)
Page
PL35F (50Hz)
Page
PL50F (50Hz)
Page
PL50F (HST/50Hz) Page

12
14
16
18

T-Series
TLY4F
TLY5FK
TLX6FK

T-Series
TL2.5F (50Hz)
TL3F
(50Hz)
TL4F
(50Hz)
TL5F
(50Hz)
TLS4F (50Hz)
TLS5F (50Hz)
TLS6F (50Hz)
TLS7F (50Hz)

Page
Page
Page
Page
Page
Page
Page
Page

20
22
24
26
28
30
32
34

N-Series
NLY5.5FK (50Hz)
NLY6F
(50Hz)
NLY7F
(50Hz)
NLY9FK
(50Hz)
NLY5.5FK.2 (50Hz)
NLY6FK.2 (50Hz)
NLY7FK.2 (50Hz)
NLY9FK.2 (50Hz)

N-Series
NL6F
(50Hz)
NL7F
(50Hz)
NL8F
(50Hz)
NL9F
(50Hz)
NL11F (50Hz)
NF7FX (50/60Hz)
NF9FX (50Hz)
NF10FX (50Hz)
NF11FX (50Hz)

Page
Page
Page
Page
Page
Page
Page
Page
Page

36
38
40
42
44
46
48
50
52

F-Series
FR7.5F (50Hz)
FR8.5F (50Hz)
FR10F (50Hz)

Page 54
Page 56
Page 58

S-Series
SC15F (50Hz)
SC18F (50Hz)
SC21F (50Hz)

Page 60
Page 62
Page 64

Energy-optimized
Compressors
P-Series
PLE35F (50Hz)
PLE50F (50Hz)
T-Series
TLES3F (50Hz)
TLES4F (50Hz)
TLES5F (50Hz)
TLES6F (50Hz)
TLES7F (50Hz)
N-Series
NLE6F (50Hz)
NLE7F (50Hz)
NLE8FK (50Hz)
NLE9F (50Hz)

Page 66
Page 68

Page
Page
Page
Page
Page

Page
Page
Page
Page

70
72
74
76
78

80
82
84
86

Universal Compressors
P-Series
PL35G
(50/60Hz) Page 144

(50Hz)
(50Hz)
(50Hz)

Page 88
Page 90
Page 92

Page
Page
Page
Page
Page
Page
Page
Page

94
96
98
100
102
104
106
108

Variable Speed Drive


Compressors
T-Series
TLV5F (50-60Hz)
TLV6F (50-60Hz)
TLV7F (50-60Hz)

Page 110
Page 112
Page 114

T-Series
TL2.5G
TL3G
TL4G
TL5G

(50/60Hz)
(50/60Hz)
(50/60Hz)
(50/60Hz)

Page
Page
Page
Page

146
148
150
152

F-Series
FR6G
(50/60Hz) Page 154
FR7.5G (50/60Hz) Page 156
FR8.5G (50/60Hz) Page 158
FR10G
(50/60Hz) Page 160
FR11G
(50Hz)
Page 162
S-Series
SC10G
(50/60Hz)
SC12G
(50/60Hz)
SC15G
(50/60Hz)
SC18G
(50/60Hz)
SC21G
(50/60Hz)
S-Series (Twins)
SC12/12G (50Hz)
SC15/15G (50Hz)
SC18/18G (50Hz)
SC21/21G (50Hz)

Page
Page
Page
Page
Page

164
166
168
170
172

Page
Page
Page
Page

174
176
178
180

Tropical Compressors
Heat Pump Compressors

T-Series
TLS3FT (50Hz)
TLS4FT (50Hz)
TLS5FT (50Hz)
TFS4FT (50Hz)
TFS4.5FT(50Hz)

Page
Page
Page
Page
Page

116
118
120
122
124

N-Series
NL6FT
NL7FT
NL9FT
NL10FT

(50/60Hz)
(50Hz)
(50Hz)
(50Hz)

Page
Page
Page
Page

126
128
130
132

S-Series
SC12FT (50/60Hz)
SC15FT (50/60Hz)
SC18FTX (50/60Hz)
SC21FTX (50/60Hz)

Page
Page
Page
Page

134
136
138
140

T-Series
TL4GH

(50/60Hz) Page 182

F-Series
FR7GH
(50/60Hz) Page 184
S-Series
SC10GH
SC12GH
SC15GH
SC18GH
SC10GHH
SC15GHH
SC10GH
SC12GH
SC15GH
SC18GH

(50Hz)
(50Hz)
(50Hz)
(50Hz)
(50Hz)
(50Hz)
(50/60Hz)
(50/60Hz)
(50/60Hz)
(50/60Hz)

Page
Page
Page
Page
Page
Page
Page
Page
Page
Page

186
188
190
192
194
196
198
200
202
204

Energy-optimized Tropical
Compressors
N-Series
NLE9FT (50Hz)

CK.40.B6.02

Page 142

August 2001

1. General

This collection of datasheets contains information on Danfoss hermetic refrigeration compressors for 220-240V especially designed for refrigeration systems using refrigerant
R134a (CF3-CH2F).
The programme consists of the basic types PL, TL, TLV, TF, NL, NF, FR, SC and SC Twin.

8238-2

8238-3

PL

8238-16

TL (TF similar)

8238-4

TLV

NL (NF similar)

8238-6

8238-5

8238-7

FR
1.1 Compressor
designations

SC

SC Twin

The compressor designations are built up according to the following system:


Compressor
design

PL

TL, TF

NL, NF

FR

SC

Optimization
level
Blank
Standard
energy level
S
Semi-direct intake
E
Energy-optimized
(optimized motor)
Y, X
High Energyoptimized
(high optimization
level)

Compressor
size

Nominal
displacement
in cm3
Exception:
For PL
compressors
the capacity at
rating point is
stated

Application
range
F
R134a LBP(MBP)
FT
R134a LBP tropical
FK
R134a LBP/(MBP) LST
FX
R134a LBP/(MBP) HST
G
R134a LBP/MBP/HBP
GH
R134a Heat pumps
GHH
R134a Heat pumps
(optimized)

Generation

Blank
First
generation
.2
Second
generation
.3
Third
generation
etc.

Example
TL

ES

NL

GH

FK

FR
NL

1.2 Design

August 2001

.2

Compressors with the denominations PL, PLE, TLS, TFS, TLES, TLY, NL, NF and NLE are
designs with semi-direct intake. Compressors with the denomination NLY are designs with
direct intake. Please note that the suction and process connectors on all TLS, TLES, and
TLY compressors have been interchanged as compared with the basic TL compressors.
Using the wrong connector as suction connector on PL, PLE, TLS, TFS, TLES, TLY, NL, NF
and NLE compressors will lead to reduced capacity and efficiency.
Using the wrong connector as suction connector on the NLYs is not allowed since the compressor will not function.

CK.40.B6.02

1.3 Type label


105G

NL6F
220-240V~50Hz
LBP LST/HST

Blue stripe
Approvals
Barcode on
white background

R134a

6606

DANFOSS COMPRESSORS

Yellow background

1.4 Data stamping

8273-3

Application

All compressors have a yellow label with the type


designation. This label has a blue stripe and the
text R134a.
The country of origin indicated on the compressor paper label and on the compressor cover
varies depending on the manufacturing place.
Information can be found on our technical information sheet Country of Origin.

The compressor type and production date are stamped on the side of the compressor. The
information may be as follows,
L--4F-4400
F-201E2207
The first line states the model designation and the code no.
L= last letter (or last two letters) of the compressor type
-4F= nominal displacement and application
4400
= 4 last digits in the code no.
(= position mark)
The second line states the date of manufacture and internal Danfoss codes.
F
= manufacturing place (F = Germany, AL = Slovenia, AM = Mexico)
20
= week 20
1
= 2001
E
= Friday (A = Monday etc.)
220
= nominal voltage
7
= internal Danfoss code

1.5 Compressor
dimensions
F

Compressors with denominations ending with F are primarily designed for low evaporating
temperatures (LBP Low Back Pressure) for use in refrigerators, freezers and similar
applications in regions with stable supply voltage.

FT

Compressors with denominations ending with FT are designed for low evaporation temperatures (LBP Low Back Pressure) for use in refrigerators, freezers and similar applications operating in regions with unstable supply voltage.

FK

Compressors with denominations ending with FK are F-types designed for low evaporation
temperatures with LST starting characteristics (capillary tube).

FX

Compressors with denominations ending with FX are F-types designed for low evaporation
temperatures with HST starting characteristics (expansion valve).

Compressors with denominations ending with G are primarily designed for high evaporation
temperatures (HBP High Back Pressure) for use in liquid coolers, dehumidifiers, refrigerated display counters, vending machines and similar applications. The compressors can
also be used for Heavy Duty purposes at low evaporating temperatures for use in refrigerators, freezers and similar applications operating in regions with unstable supply voltage.

GH

Compressors with denominations ending with GH are designed for high evaporating temperatures for cooling of electronic cabinets and for use in heat pump systems.

GHH

Compressors with denominations ending with GHH are optimized versions of GH compressors.
The table on page 5 shows the normally recommended applications as regards voltage/
frequency, ambient temperature, evaporating temperature and necessary compressor
cooling. The recommendations must be regarded as a guideline only as they presuppose
a proper dimensioning of the refrigeration system.

2. Application range

The build-in conditions (total height, weight, tube dimensions etc.) are specified in the
individual datasheets including dimensioned sketches for the compressors.

CK.40.B6.02

August 2001

SC12 - 15FT
SC18 - SC21FTX
PL35G

TL2.5G

TL3 - 4 - 5G

FR6G

FR7.5G
G

FR8.5 - 10G
FR11G
SC10

SC12 - 15 - 18G

SC21G
SC12/12G
SC15/15G Twin
SC18/18G
SC21/21G Twin
TL4GH
FR7GH
GH

SC10 - 12 - 15 GH
SC18GH
SC10 - 12 - 15 - 18GH

GHH

August 2001

SC10 - 15GHH

F2

S
S*1)
S*
S
S*
S

S*
S*

S
S
S
S
O/F1
O/F1
S
F2
F2***
F2
F2

F2
F2

F2

F2

F2

F2

F2

F2

F2

F2

O/F1

F2

F2

O/F1

F2

O/F1

F2

F2

F2

F2

F2

F2

F2

F1

F2

F1

F2

F1

F2

O/F1

F2

O/F1

F2

O/F1

F2

F2

F2

F2

F2

F2**

F2

198 - 254 /50

F2

F2

F2

F2

F2

F2

198 - 254 /50


198 - 254 /50
198 - 254 /60
198 - 254 /50
198 - 254 /60
198 - 254 /50
198 - 254 /50
198 - 254 /50
198 - 254 /60
198 - 254 /50

F2

F2

F2

F2

F2**

F2

F2

F2

F2

O/F1

O/F1

O/F1

F1
F2

F1
F2

F1
F2

F2

F2

F2

CK.40.B6.02

The application limits regarding evaporating temperatures and motor systems are specified in the individual compressor datasheets.

NL7FT
NL9 - 10FT
NLE9FT

HBP

Run capacitor compulsory


Run capacitor recommended
Not applicable below -25C evaporating temperature in 43C ambient temp. above 240V
O/F1 possible at 220V nominal (187-242V)

FT
FTX

43C
LBP

=
=
=
=

NL6FT

HBP

*
*1)
**
***

NF9FX
NF10FX
NF11FX
NL6 - 7 - 8 - 9F
NL11F
NLE6 - 7 - 9F - NLE8FK
NLY6 - 7F - NLY5.5 - 9FK
NLY5.5 - 6 - 7 - 9FK.2
FR7.5 - 8.5 -10F
SC15 - 18 - 21F
TFS4 - 4.5FT
TLS3 - 4 - 5FT

LBP
S
S*
S
S
S
S
S
S
S
S
S
S*
S
S
F1
O/F1
F1
F2
S
O/F1
S
S*
S*
S
O/F1
S
S
S
S
S
S
S
O/F1
O/F1
F2
F2
F2
F2

Ambient temperature
38C
LBP
HBP
S
S*
S
S
S*
S
S
S*
S*
S
S
S*
S
F1
F1
O/F1
F2
F2
S
O/F1
S
S*
S*
S
O/F1
S
S
S
S
S
O/F1
S
O/F1
O/F1
F2
F2
F2
F2
F2

Static cooling normally sufficient


Oil cooling
Fan cooling 1.5 m/s (compressor compartment temperature equal to ambient temp.)
Fan cooling 3.0 m/s necessary
Outside application range, not recommended

NF7FX

198 - 254 /50


198 - 254 /50
198 - 254 /50
198 - 254 /50
198 - 254 /50
198 - 254 /50
198 - 254 /50
198 - 254 /50
198 - 254 /50
198 - 254 /50
198 - 254 /50
198 - 254 /50
198 - 254 /50-60
198 - 242 /50
198 - 242 /60
198 - 242 /50
198 - 242 /50
198 - 242 /50
198 - 254 /50
198 - 254 /50
198 - 254 /50
198 - 254 /50
198 - 254 /50
198 - 254 /50
198 - 254 /50
176 - 242 /50
187 - 254 /50
187 - 254 /50
198 - 254 /60
187 - 254 /50
187 - 254 /50
187 - 254 /50
187 - 254 /50
198 - 254 /60
187 - 254 /50
198 - 254 /60
198 - 254 /50
198 - 254 /60
187 - 254 /50
198 - 254 /50
198 - 254 /60
207 - 254 /60
187 - 254 /50
198 - 254 /50
198 - 254 /60
187 - 254 /50
198 - 254 /50
198 - 254 /60
187 - 254 /50
198 - 254 /50
198 - 254 /60
187 - 254 /50
198 - 254 /50
198 - 254 /60
198 - 254 /50
187 - 254 /50
198 - 254 /50
198 - 254 /60
187 - 254 /50
198 - 254 /50
198 - 254 /60
187 - 254 /50
198 - 254 /50
198 - 254 /60

32C

=
=
=
=
=

F
FK
FK.2
FX

PL20 - 35 - 50F
PLE35 - 50F
TL2.5 - 3 - 4 - 5F
TLS4 - 5 - 6F
TLS7F
TLES3 - 4F
TLES5F
TLES6F
TLES7F
TLY4F
TLY5FK
TLX6FK
TLV5 - 6 - 7F

Mains [V/Hz]

S
O
F1
F2

Compressor

2.1 Design limits

Condensing temperature
Winding temperature

3. Electrical equipment

In order to secure a satisfying lifetime of the compressor, and to protect the compressor
against overload, some design criteria for the appliances must be fulfilled.
Both the condensing temperature and the compressor temperature should be kept as
low as possible. This can be done by using well-dimensioned condenser surfaces and by
ensuring good ventilation around the compressor under all operating conditions.
In order to protect the compressor against overload, the compressor has to start and
work properly through pressure peaks obtained in the highest ambient temperature and
lowest obliging voltage. At peak load the condensing temperature must not exceed 70C.
The winding temperature must not exceed 135C.
At stable operation conditions the condensing temperature must not exceed 60C. The
winding temperature must not exceed 125C.
These limitations secure a protection of valves, gaskets, oil, and motor insulation.

The compressors are equipped with a single-phase AC motor. With the exception of the
smallest TL and the biggest SC compressors the TL, TLS, NL, FR, and SC compressors
are designed with universal motors which means that they can obtain a high (HST) or low
starting torque (LST) depending on the external electrical equipment used.
The electrical equipments are classified as normal tight (IP20)
The motor protector is built into the motor (winding protector).
Earth connections are located on the bracket around the current lead-in of the compressor.
No attempt must be made to start the compressor without a complete starting device.
The compressors can be supplied with the following motor systems:

8073

8074

3.1 LST (RSIR)

PL, TL, NL, FR

TFS

8190

Compressors with the motor type Resistant Start


Induction Run (RSIR) have a starting device for
Low Starting Torque (LST). The design of the
electrical equipment depends on the actual compressor design. The following designs of starting
devices exist:
a) PTC + cord relief + cover, the motor protector
is built into the motor (winding protector), used
for compressors with the denominations PL, TL,
NL, FR, and SC.
b) Relay housing including motor protector + cord
relief + cover, used for compressors with the
denomination TFS.
The PTC starting device requires a pressureequalization before each start. This starting
SC
device is normally used in well-designed refrigerating systems with capillary tube as throttling device. The PTC needs a compressor
standstill period of 5 minutes to cool down before each start.
6

CK.40.B6.02

August 2001

Compressors with the motor type Resistant


Start Capacitor Run (RSCR) have a starting
device for Low Starting Torque (LST). This starting device consists of a PTC and a run capacitor
and is mandatory for compressors with the denominations PLE, TLY and NLY. The PTC starting device requires a pressure-equalization
before each start. This starting device is normally used in well-designed refrigerating systems with capillary tube as throttling device.
8075

3.2 LST (RSCR)

PLE, TLES, TLY, NLE, NLY

8076

8077-2

3.3 HST (CSIR)

PL, TL, NL, FR

NF

8088

Compressors with the motor type Capacitor Start Induction Run (CSIR) have a starting
device for High Starting Torque (HST). This starting device consists of a starting relay and
a starting capacitor and is used for compressors with the denominations TL, NL, NF, FR
and SC. The following designs of starting devices exist:
a) Relay + starting capacitor + cord relief + cover, used for compressors with the denominations TL, NL, FR and SC.
b) Relay housing including motor protector + starting capacitor + cord relief (2x) + cover,
used for compressors with the denomination NF.
The starting device requires no pressure-equalization before each start and is normally
used in refrigerating systems with expansion valve as throttling device or in capillary tube
systems where pressure equalizing is not obtained during the standstill periods. The starting
device is mandatory for NF-FX compressors and
for some of the biggest SC compressors.
The starting capacitor is designed for short time
cut-in. 1.7% ED, which is stamped on the starting capacitor, means for instance max. 10 cutins per hour each with a duration of 6 seconds.

SC
August 2001

CK.40.B6.02

Compressors with the motor type Capacitor Start


Run (CSR) have a starting device for High
Starting Torque (HST). This starting device consists of a starting relay, a starting capacitor, a
run capacitor, a terminal board, a cord relief,
and a cover. The starting device is mandatory
for some of the biggest SC compressors. The
starting capacitor is designed for short time cutin. 1.7% ED, which is stamped on the starting
capacitor, means for instance max. 10 cut-ins
per hour each with a duration of 6 seconds.
8191

3.4 HST (CSR)

SC

3.5 Electronic unit


(variable speed)

8434

TLV

The variable speed compressor motors


are electronically controlled. No attemp
must be made to start the compressor
without a complete electronic unit, as
specified in the data sheet for the compressor type in question.
The electronic unit has a built-in overload protection as well as thermal protection. In case of activation of this
protection the electronic unit will protect the compressor motor as well as
itself. When the protection has been
activated, the electronic unit automatically will restart the compressor after
a certain time. The electronic unit
provides the compressor with High
Starting Torque (HST) which means
that a pressure-equalizeation of the
system before start is not necessary.

The compressors are equipped with permanent magnet rotors (PM motor) and 3 identical
stator windings. The electronic unit is mounted directly on the compressor and controls the
PM motor.
Connecting the motor to AC mains, by fault, will damage the magnets and lead to drastically
reduced efficiency, or even non functioning.

For further information on which starting device to use on individual compressors, please
refer to the actual datasheets (some compressors have limitations for either LST or HST).

CK.40.B6.02

August 2001

3.6 Connections

The electrical equipments are equipped with connectors depending on the ordered code
number,
Starting relays:
6.3 mm spade connectors only
PTCs:
6.3 or 4.8 mm spade connectors and screws
Variable speed electronic unit: 6.3 spade connectors only
The power supply must be connected as shown in the wiring diagrams for the chosen
electrical equipment given in the actual datasheets.

The compressors have been approved in respect of safety by testing authorities in the
majority of Western European countries. Actual standards to which the compressors
have been approved are specified in the individual datasheets. Approval markings appear
on the compressor labels.
To fulfil the requirements of EN 60355-2-34 the protection
screen 103N0476 must be applied to the PTC starting device.

7363

Most compressors which are capable


of running at 60Hz have been approved
in respect of safety by testing authorities UL and CSA.
Actual standards to which the compressors have been approved are
specified in the individual datasheets.
Approval markings appear on a separate approval mark label.

TL3G
230V-60Hz
1PH
THERMALLY
PROTECTED

8284-4

3.7 Approvals

Approval mark

Protection screen

4. Moisture and
impurities

The compressors are dried to a maximum moisture content of 60 to 75 mg depending on


the compressor size. The maximum impurity content is 40 to 50 mg depending on the
compressor size.

5. Max. refrigerant
charge

The refrigerant charge must never be too large to be contained on the condenser side of
the refrigeration system. Only the refrigerant amount which is necessary for the system
to function must be charged.
The refrigerant amount may be critical as regards oil foaming and liquid hammer after
long standstill periods. Because of this, limitations of refrigerant charges have been
introduced. The maximum refrigerant charge is specified in the individual datasheets.
If these limitations cannot be complied with, the risk may be reduced if a crankcase heater
is properly used or if a pump down system is established.

6. Oil charge

The compressors are supplied charged with dried and degassed oil, which is normally
sufficient for the lifetime of the compressor. The refrigeration systems and the system
components must be dimensioned in such a way that the oil can be lead back continuously
to the compressor housing without accumulating in the system, e.g. without oil pockets
and with sufficient gas velocity. The compressors use polyolester oils and are approved
only for these oils and R134a.
The oil charge is specified in the individual datasheets.

August 2001

CK.40.B6.02

7. Mounting

Soldering problems caused by oil in the connectors can be avoided by placing the compressor on its baseplate some time before soldering it into the system. The compressor
must never be placed upside down when mounting the rubber grommets in the baseplate.
Instead place the compressor on its side with the connectors upwards.

7.1 Mounting
accessories

Washer

Nut M6

Washer

Grommet sleeve

Steel pin

Compressor base

Clip

Compressor base

3327-2

7382-2

Cabinet base
Cabinet base

Screw M6 x 25

Rubber grommet

Rubber grommet

Bolt joint

Snap-on joint

The mounting accessories for the compressors are available in two versions, with bolt joint
or snap-on joint. The code numbers for the mounting accessories are specified in the individual compressor datasheets.
These rubber grommets are designed for the 16 mm holes of the baseplate:
Bolt joint for one compressor in a bag 118-1917 or 118-1946
Bolt joint in quantities
118-1918 or 118-1945
Snap-on in quantities
118-1919 or 118-1944
Snap-on for one compressor in a bag
118-1947
These rubber grommets are designed for the 19 mm holes of the baseplate:
Bolt joint in quantities
118-1948

8. Condition at delivery

The compressors are delivered without mounted starting devices on pallets with the dimensions 1144 x 800 mm. Quantities per pallets are specified in the individual datasheets. Electrical equipment is packed in separate boxes.
The most important performance controls carried out during manufacturing are,
A high potential insulation test with 1650V for 1 second
Pumping capacity
Tightness of discharge side and discharge valve
Tightness of compressor housing
Check of the right oil charge
Noise test
The compressors are supplied with sealed connectors and the sealing should not be
removed before the system assembly takes place
(max. 15 minutes with open connectors).

9. Twin-compressors

The Twin version consists of two SC compressors mounted on a common baseplate. The
two compressors are joined by an oil-equalizing tube and also have an intake manifold
with screw connector for a service valve or a solder connector (these parts are supplied
as accessories).
Each Twin compressor is supplied with two sets of electrical equipment and mounting
accessories. To ensure optimum starting characteristics and the smallest possible mains
load we recommend that the compressors be equipped with a time-delay relay for start of
the second compressor.Twin compressors can operate with capacity regulation depending
on the controls used.

10

CK.40.B6.02

August 2001

10. Conversion from


R12 to R134a

Normally, the capillary tube shall be adjusted at low evaporating temperatures. Compared
to an optimized R12 system with the same evaporator capacity, the R134a system must
have an increased resistance defined as approx. 10% less N2 flow at 10 bar inlet pressure.
The same size of capillary tube as used for R12 can be used at high evaporating temperatures.
A drier with 3 desiccant of Molecular Sieves must always be used.
Rules for dryness and cleanliness of system components (DIN 8964) are transferred to
R134a systems.
The system components must not contain mineral oil or greasy substances.
The compressors must be soldered into the system no later than 15 minutes after the
connector seals have been removed.
The same evacuation procedure as for R12 systems must be used.
Max. 1% non-condensable gases.
The system must not contain any chlorine.
The charging equipment must only be used for R134a.
If the same vacuum pump is to be used for R12 and R134a systems, a special Ester oil
must be used in agreement with the pump supplier.

11. Warnings

August 2001

No high potential test nor start tests must be carried out while the compressor is under
vacuum.
No attempt must be made to start the compressor without a complete starting device.
Allow the compressor to assume a temperature above 10C before starting the first time
in order to avoid starting problems.
Anti-freeze agents must not be used in the compressors as such agents are damaging to
several of the materials used. In particular, the ethyl or methyl alcohol contents of such
anti-freeze agents have a destructive effect on the synthetic motor insulation.

CK.40.B6.02

11

PL20F
Standard Compressor
R134a
220-240V 50Hz
Data Sheet (Replaces CD.41.B6.02)
General
PL20F

Code number

101G0100

PL20F
R134a

Blue stripe

Application

101G

Application

0100

Approvals

Application
Evaporating temperature range
Voltage range

C
V/Hz

MBP

Barcode on
white background

-25 to 0

Yellow background

DANFOSS COMPRESSORS

8270-2

Compressor

198 - 254 /50

Motor type

RSIR

Max. ambient temperature


Comp. cooling at ambient temp.

38

32C

38C

S
O
F1
F2

= Static cooling normally sufficient


= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

Design
Displacement

cm3

Oil quantity

cm3

150

300

cm3

800

kg

3.8

Maximum refrigerant charge


Free gas vol. in compressor
Weight without electrical equipment

1.41

Motor
Motor size

watt

29

LRA (rated after 4 sec. UL984) LST

1.2

Cut-in current LST

5.7

Resistance, main and start winding (25C)

84.0/19.0
100

EN 60335-2-34 with Annex AA


35
70

Approvals

204
170

Dimensions
Height

Suction connector

mm

location/I.D. mm

129

127

B1

120

B2

73

6.2 0.09

Process connector

location/I.D. mm

6.2 0.09

Discharge connector

location/I.D. mm

5.0 +0.12/+0.20

pcs.

B1 B A
B2
206

150

8241

46
59
130

50
60.5

Compressors on a pallet

16

127

April 2001

12

CD.41.B7.02

CK.40.B6.02

August 2001

Capacity (EN 12900/CECOMAF)


Comp.\C
PL20F

-25
16.0

-23.3
19.0

-20
25.4

watt
-15
36.5

-10
49.6

-5
64.9

0
82.6
g

Capacity (ASHRAE)
Comp.\C
PL20F

-25
19.7

-23.3
23.4

watt
-20
31.3

-15
45.0

-10
61.3

-5
80.3

-20
46.4

-15
51.5

-10
57.2

-5
63.3

0
69.7

-20
0.36

-15
0.37

-10
0.39

-5
0.41

0
0.43

Power consumption
Comp.\C
PL20F

-25
42.0

-23.3
43.4

0
102

-25
0.35

-23.3
0.35

-25
0.38

-25
0.47

d
Main winding a1 Start winding
N

W/W

-23.3
0.44

-20
0.55

-15
0.71

-10
0.87

-5
1.03

-23.3
0.54

-20
0.67

-15
0.87

-10
1.07

-5
1.27

COP (ASHRAE)
Comp.\C
PL20F

a1

COP (EN 12900/CECOMAF)


Comp.\C
PL20F

8224

watt

Current consumption
Comp.\C
PL20F

0
1.19

W/W

Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Static cooling, 220V 50Hz,
PTC consumption incl.

EN 12900/CECOMAF
55C
32C
55C

0
1.47

Winding protector

ASHRAE
55C
32C
32C

Accessories
Devices
PTC starting device

6.3 mm spades
4.8 mm spades

Fig.

PL20F

a1

103N0011
103N0018

Cover

103N0491

Cord relief

103N1010

Protection screen for PTC

103N0476

Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities

August 2001

118-1917
118-1918
118-1919

CD.41.B7.02

CK.40.B6.02

April 2001

13

PL35F
Standard Compressor
R134a
220-240V 50Hz
Data Sheet (Replaces CD.41.E1.02)
General
PL35F

Code number

101G0202

PL35F
R134a

Blue stripe

Application

101G

Application

0202

Approvals

Application
Evaporating temperature range
Voltage range

C
V/Hz

MBP

Barcode on
white background

-25 to 0

Yellow background

DANFOSS COMPRESSORS

8270

Compressor

198 - 254 /50

Motor type

RSIR

Max. ambient temperature


Comp. cooling at ambient temp.

38

32C

38C

S
O
F1
F2

= Static cooling normally sufficient


= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

Design
Displacement

cm3

Oil quantity

cm3

150

300

cm3

830

kg

4.1

Maximum refrigerant charge


Free gas vol. in compressor
Weight without electrical equipment

2.00

Motor
Motor size

watt

43

LRA (rated after 4 sec. UL984) LST

1.7

Cut-in current LST

5.6

Resistance, main and start winding (25C)

204
170

52.0/19.0
100

EN 60335-2-34 with Annex AA


35
70

Approvals

Dimensions
Height

Suction connector

mm

location/I.D. mm

134

132

B1

125

B2

73

6.2 0.09

Process connector

location/I.D. mm

6.2 0.09

Discharge connector

location/I.D. mm

5.0 +0.12/+0.20

pcs.

B1 B A
B2
206

150

8241

46
59
130

50
60.5

Compressors on a pallet

16

127

July 2001

14

CD.41.E2.02

CK.40.B6.02

August 2001

Capacity (EN 12900/CECOMAF)


Comp.\C
PL35F

-25
32

-23.3
36

-20
45

watt
-15
60

-10
79

-5
101

0
125
g

Capacity (ASHRAE)
Comp.\C
PL35F

-25
39

-23.3
44

watt
-20
55

-15
74

-10
97

-5
124

-20
57

-15
64

-10
72

-5
80

0
88

-20
0.51

-15
0.53

-10
0.55

-5
0.58

0
0.62

Power consumption
Comp.\C
PL35F

-25
50

-23.3
52

0
155

-25
0.50

-23.3
0.50

-25
0.64

-25
0.78

d
Main winding a1 Start winding
N

W/W

-23.3
0.69

-20
0.79

-15
0.94

-10
1.10

-5
1.26

-23.3
0.85

-20
0.97

-15
1.16

-10
1.36

-5
1.55

COP (ASHRAE)
Comp.\C
PL35F

a1

COP (EN 12900/CECOMAF)


Comp.\C
PL35F

8224

watt

Current consumption
Comp.\C
PL35F

0
1.42

W/W

Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Static cooling, 220V 50Hz,
PTC consumption incl.

EN 12900/CECOMAF
55C
32C
55C

0
1.76

Winding protector

ASHRAE
55C
32C
32C

Accessories
Devices
PTC starting device

6.3 mm spades
4.8 mm spades

Fig.

PL35F

a1

103N0011
103N0018

Cover

103N0491

Cord relief

103N1010

Protection screen for PTC

103N0476

Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities

August 2001

118-1917
118-1918
118-1919

CD.41.E2.02

CK.40.B6.02

July 2001

15

PL50F
Standard Compressor
R134a
220-240V 50Hz
Data Sheet (Replaces CD.41.F1.02)
General
PL50F

Code number

101G0220

PL50F
R134a

Blue stripe

Application

101G

Application

0220

Approvals

Application
Evaporating temperature range
Voltage range

C
V/Hz

LBP

Barcode on
white background

-35 to -10

Yellow background

DANFOSS COMPRESSORS

8270-3

Compressor

198 - 254 /50

Motor type

RSIR

Max. ambient temperature


Comp. cooling at ambient temp.

38

32C

38C

S
O
F1
F2

= Static cooling normally sufficient


= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

Design
Displacement

cm3

Oil quantity

cm3

150

300

cm3

850

kg

4.3

Maximum refrigerant charge


Free gas vol. in compressor
Weight without electrical equipment

2.50

Motor
Motor size

watt

54

LRA (rated after 4 sec. UL984) LST

2.2

Cut-in current LST

6.0

Resistance, main and start winding (25C)

38.0/20.0
100

EN 60335-2-34 with Annex AA


35
70

Approvals

204
170

Dimensions
Height

Suction connector

mm

location/I.D. mm

137

135

B1

128

B2

73

6.2 0.09

Process connector

location/I.D. mm

6.2 0.09

Discharge connector

location/I.D. mm

5.0 +0.12/+0.20

pcs.

B1 B A
B2
206

150

8241

46
59
130

50
60.5

Compressors on a pallet

16

127

April 2001

16

CD.41.F2.02

CK.40.B6.02

August 2001

Capacity (EN 12900/CECOMAF)


Comp.\C
PL50F

-35
14.2

-30
26.2

-25
40.0

watt
-23.3
45.1

-20
55.8

-15
74.1

-10
95.2
g

Capacity (ASHRAE)
Comp.\C
PL50F

-35
17.4

-30
32.3

watt
-25
49.3

-23.3
55.6

-20
68.9

-15
91.5

-25
60.0

-23.3
62.7

-20
68.1

-15
76.5

-10
85.6

-25
0.50

-23.3
0.51

-20
0.53

-15
0.55

-10
0.58

Power consumption
Comp.\C
PL50F

-35
43.6

-30
51.9

-10
118

-35
0.47

-30
0.48

-35
0.32

-35
0.40

d
Main winding a1 Start winding
N

W/W

-30
0.50

-25
0.67

-23.3
0.72

-20
0.82

-15
0.97

-30
0.62

-25
0.82

-23.3
0.89

-20
1.01

-15
1.20

COP (ASHRAE)
Comp.\C
PL50F

a1

COP (EN 12900/CECOMAF)


Comp.\C
PL50F

8224

watt

Current consumption
Comp.\C
PL50F

-10
1.11

W/W

Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Static cooling, 220V 50Hz,
PTC consumption incl.

EN 12900/CECOMAF
55C
32C
55C

-10
1.38

Winding protector

ASHRAE
55C
32C
32C

Accessories
Devices
PTC starting device

6.3 mm spades
4.8 mm spades

Fig.

PL50F

a1

103N0011
103N0018

Cover

103N0491

Cord relief

103N1010

Protection screen for PTC

103N0476

Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities

August 2001

118-1917
118-1918
118-1919

CD.41.F2.02

CK.40.B6.02

April 2001

17

PL50F
Standard Compressor
HST Starting Characteristics
R134a
220-240V 50Hz
Data Sheet (Replaces CD.41.G1.02)
General
PL50F

Code number

101G0222

PL50F
R134a

Blue stripe

Application

101G

Application

0222

Approvals

Application
Evaporating temperature range
Voltage range

C
V/Hz

MBP

Barcode on
white background

-25 to 0

Yellow background

DANFOSS COMPRESSORS

8283-2

Compressor

198 - 254 /50

Motor type

CSIR

Max. ambient temperature


Comp. cooling at ambient temp.

38

32C

F2

38C

F2

S
O
F1
F2

= Static cooling normally sufficient


= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

Design
Displacement

cm3

Oil quantity

cm3

150

300

cm3

850

kg

4.3

Maximum refrigerant charge


Free gas vol. in compressor
Weight without electrical equipment

2.50

Motor
Motor size

watt

54

LRA (rated after 4 sec. UL984) HST

4.2

Cut-in current HST

4.2

Resistance, main and start winding (25C)

38.0/14.0
100

EN 60335-2-34 with Annex AA


35
70

Approvals

204
170

Dimensions
Height

Suction connector

mm

location/I.D. mm

137

135

B1

128

B2

73

6.2 0.09

Process connector

location/I.D. mm

6.2 0.09

Discharge connector

location/I.D. mm

5.0 +0.12/+0.20

pcs.

B1 B A
B2
206

150

8241

46
59
130

50
60.5

Compressors on a pallet

16

127

April 2001

18

CD.41.G2.02

CK.40.B6.02

August 2001

Capacity (EN 12900/CECOMAF)


Comp.\C
PL50F

-25
40.0

-23.3
45.1

-20
55.8

watt

-15
74.1

-10
95.2

-5
120

0
148
c

Capacity (ASHRAE)
Comp.\C
PL50F

-25
49.3

-23.3
55.6

watt
-20
68.9

-15
91.5

-10
118

-5
148

0
183
b

Power consumption
Comp.\C
PL50F

-25
58.0

-23.3
60.7

watt
-20
66.1

-15
74.5

-10
83.6

-5
93.7

8225

0
105

a2
d

Current consumption
Comp.\C
PL50F

-25
0.50

-23.3
0.51

A
-20
0.53

-15
0.55

-10
0.58

-5
0.62

0
0.66

c
11

10

COP (EN 12900/CECOMAF)


Comp.\C
PL50F

-25
0.69

W/W

-23.3
0.74

-20
0.84

-15
0.99

-10
1.14

-5
1.28

-23.3
0.92

-20
1.04

-15
1.23

-10
1.41

-5
1.58

COP (ASHRAE)
Comp.\C
PL50F

-25
0.85

0
1.41

12

13
14

W/W

Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Fan cooling, 220V 50Hz

EN 12900/CECOMAF
55C
32C
55C

0
1.74

Main winding
Winding protector

Start winding

ASHRAE
55C
32C
32C

Accessories
Devices

Fig.

PL50F

Starting relay

a2

117U6021

Cover

103N0491

Starting capacitor 60 F

117U5014

Cord relief

103N1010

Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities

August 2001

118-1917
118-1918
118-1919

CD.41.G2.02

CK.40.B6.02

April 2001

19

TL2.5F
Standard Compressor
R134a
220-240V 50Hz
Data Sheet (Replaces CD.42.S3.02)
General
TL2.5F

102G

TL2.5F

Code number (small baseplate)

102G4200

Code number (large baseplate)

102G4201

Application

R134a

Blue stripe
Approvals

4200

Barcode on
white background

Application
Application

MBP

Evaporating temperature range


Voltage range

-25 to 0

V/Hz

198 - 254 /50

Motor type

RSIR

Max. ambient temperature

38

32C

38C

Displacement

cm3

2.61

Oil quantity

cm3

180

400

cm3

1600

kg

6.7

Comp. cooling at ambient temp.

DANFOSS COMPRESSORS

Yellow background

8271-2

Compressor

S
O
F1
F2

= Static cooling normally sufficient


= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

Design

Maximum refrigerant charge


Free gas vol. in compressor
Weight without electrical equipment

3.6

16

LRA (rated after 4 sec. UL984) LST

watt

60

2.3

35
70
100

Motor size

Cut-in current LST

7.0

Resistance, main and start winding (25C)

40.0/15.0

19

Approvals

163
159

Suction connector

location/I.D. mm

C 6.2 0.09

6.5 0.09

Process connector

location/I.D. mm

D 6.2 0.09

6.5 0.09

Discharge connector

location/I.D. mm

E 5.0 +0.12/+0.20

Compressors on a pallet

pcs.

D
C

or

222
176

31.5
28

A
B

C or
D

A B

105
107

mm

102G4201

30

102G4200

105

Height

170
178
186
204

EN 60335-2-34 with Annex AA, CCIB

Dimensions

101.6
136

Motor

5.0 +0.12/+0.20
125

102

June 2001

20

CD.42.S4.02

CK.40.B6.02

71

29

51 20

45

157
60.5
66

8428

96
117

August 2001

Capacity (EN 12900/CECOMAF)


Comp.\C
TL2.5F

-25
32

-23.3
37

-20
47

watt
-15
65

-10
86

-5
110

0
137
g

Capacity (ASHRAE)
Comp.\C
TL2.5F

-25
39

-23.3
45

watt
-20
58

-15
80

-10
106

-5
136

0
169

-20
63

-15
71

-10
80

-5
89

0
98

-20
0.46

-15
0.49

-10
0.52

-5
0.55

0
0.58

Power consumption
Comp.\C
TL2.5F

-25
54

-23.3
57

-25
0.44

-23.3
0.45

-25
0.59

-25
0.73

d
Main winding a1 Start winding
N

W/W

-23.3
0.64

-20
0.75

-15
0.91

-10
1.07

-5
1.24

-23.3
0.79

-20
0.92

-15
1.12

-10
1.33

-5
1.53

0
1.40

COP (ASHRAE)
Comp.\C
TL2.5F

a1

COP (EN 12900/CECOMAF)


Comp.\C
TL2.5F

8217

watt

Current consumption
Comp.\C
TL2.5F

W/W

Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Static cooling, 220V 50Hz,
PTC consumption incl.

EN 12900/CECOMAF
55C
32C
55C

0
1.73

Winding protector

ASHRAE
55C
32C
32C

Accessories
Devices
PTC starting device

6.3 mm spades
4.8 mm spades

Fig.

TL2.5F

a1

103N0011
103N0018

Cover

103N2010

Cord relief

103N1010

Protection screen for PTC

103N0476

Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities

August 2001

118-1917
118-1918
118-1919

CD.42.S4.02

CK.40.B6.02

June 2001

21

TL3F
Standard Compressor
R134a
220-240V 50Hz
Data Sheet (Replaces CD.42.I5.02)
General
TL3F

Code number

102G4300

102G

TL3F
Application

R134a

Blue stripe
Approvals

Application
Application
Evaporating temperature range
Voltage range

C
V/Hz

MBP

Barcode on
white background

-25 to 0

Yellow background

4300

8271-3

Compressor

DANFOSS COMPRESSORS

198 - 254 /50

Motor type

RSIR/CSIR

Max. ambient temperature


Comp. cooling at ambient temp.

38

32C

38C

S
O
F1
F2

= Static cooling normally sufficient


= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

Design
Displacement

cm3

Oil quantity

cm3

180

400

cm3

1600

kg

6.7

Maximum refrigerant charge


Free gas vol. in compressor
Weight without electrical equipment

3.13

16

Motor
watt

LRA (rated after 4 sec. UL984) LST/HST

75

2.8/4.5

Cut-in current LST/HST

7.5/4.5

Resistance, main and start winding (25C)

31.5/15.0

Approvals

163

159

location/I.D. mm

6.2 0.09

Process connector

location/I.D. mm

6.2 0.09

Discharge connector

location/I.D. mm

5.0 +0.12/+0.20

C or
D

pcs.

105

105
107

A B

Compressors on a pallet

D
C

or

222
176

30

mm

170
178
186
204

31.5
28

Suction connector

EN 60335-2-34 with Annex AA, CCIB

Dimensions
Height

35
70
100

Motor size

125

102

June 2001

22

CD.42.I6.02

CK.40.B6.02

71

29

51 20

45

157
60.5
66

8263

96
117

August 2001

Capacity (EN 12900/CECOMAF)


Comp.\C
TL3F

-25
42

-23.3
48

-20
60

watt
-15
82

-10
108

-5
138

0
173

HST
c

Capacity (ASHRAE)
Comp.\C
TL3F

-25
52

-23.3
59

watt
-20
74

-15
101

-10
133

-5
171

0
214
b

Power consumption
Comp.\C
TL3F

-25
66

-23.3
69

watt
-20
76

-15
87

-10
99

-5
111

8219

0
124

a2
d

Current consumption
Comp.\C
TL3F

-25
0.50

-23.3
0.51

A
-20
0.52

-15
0.54

-10
0.57

-5
0.61

0
0.67

c
11

10

COP (EN 12900/CECOMAF)


Comp.\C
TL3F

-25
0.64

W/W

-23.3
0.69

-20
0.79

-15
0.94

-10
1.09

-5
1.24

-23.3
0.85

-20
0.97

-15
1.16

-10
1.35

-5
1.53

COP (ASHRAE)
Comp.\C
TL3F

-25
0.78

0
1.39

12

13
14

W/W

Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Static cooling, 220V 50Hz,
PTC consumption incl.

EN 12900/CECOMAF
55C
32C
55C

0
1.72

Main winding

ASHRAE
55C
32C
32C

Winding protector Start winding

LST
g

b
8217

a1

Accessories
Devices

Fig.

TL3F

a1

103N0011
103N0018

Starting relay

a2

117U6007

PTC starting device

6.3 mm spades
4.8 mm spades

Main winding a1 Start winding


N

Cover

103N2010

Starting capacitor 60 F

117U5014

Cord relief

103N1010

Protection screen for PTC

103N0476

Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities

August 2001

118-1917
118-1918
118-1919

Winding protector

CD.42.I6.02

CK.40.B6.02

June 2001

23

TL4F
Standard Compressor
R134a
220-240V 50Hz
Data Sheet (Replaces CD.42.Z1.02)
General
TL4F

102G

TL4F

Code number

102G4400

Code number

102G4426

Application

R134a

Blue stripe
Approvals

Application
Application
Evaporating temperature range
Voltage range

4400

Barcode on
white background

LBP

8271-4

Compressor

DANFOSS COMPRESSORS

Yellow background

-35 to -10

V/Hz

198 - 254 /50

Motor type

RSIR/CSIR

Max. ambient temperature


Comp. cooling at ambient temp.

38

32C

38C

S
O
F1
F2

= Static cooling normally sufficient


= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

Design
Displacement

cm3

Oil quantity

cm3

180

400

cm3

1600

kg

6.7

Maximum refrigerant charge


Free gas vol. in compressor
Weight without electrical equipment

3.86

16

Motor size

watt

85

alternative motor

80

LRA (rated after 4 sec. UL984) LST/HST

3.2/4.8

alternative motor

3.2/4.6
A

170
178
186
204

7.5/4.8

alternative motor

7.8/4.6

Resistance, main and start winding (25C)

25.7/16.3

26.8/13.5
EN 60335-2-34 with Annex AA, CCIB

31.5
28

163

159

Suction connector

location/I.D. mm

C 6.2 0.09

6.5 0.09

Process connector

location/I.D. mm

D 6.2 0.09

6.5 0.09

Discharge connector

location/I.D. mm

E 5.0 +0.12/+0.20

pcs.

5.0 +0.12/+0.20
125

105

45

Compressors on a pallet

8263

102

June 2001

24

CD.42.Z2.02

CK.40.B6.02

51 20

mm

102G4426

157
60.5
66

Height

102G4400

105
107

A B

Dimensions

71

Approvals

D
C

or

222
176

29

alternative motor

C or
D

30

Cut-in current LST/HST

35
70
100

Motor

96
117

August 2001

Capacity (EN 12900/CECOMAF)


Comp.\C
TL4F

-35
31

-30
44

-25
61

watt
-23.3
67

-20
81

-15
107

-10
137

HST
c

Capacity (ASHRAE)
Comp.\C
TL4F

-35
38

-30
54

watt
-25
75

-23.3
83

-20
100

-15
131

-10
170
b

Power consumption
Comp.\C
TL4F

-35
60

-30
70

watt
-25
81

-23.3
85

-20
93

-15
107

8219

-10
122

a2
d

Current consumption
Comp.\C
TL4F

-35
0.51

-30
0.53

A
-25
0.55

-23.3
0.56

-20
0.58

-15
0.63

-10
0.69

c
11

10

COP (EN 12900/CECOMAF)


Comp.\C
TL4F

-35
0.52

W/W

-30
0.63

-25
0.75

-23.3
0.79

-20
0.88

-15
1.00

-10
1.12

-30
0.77

-25
0.92

-23.3
0.98

-20
1.08

-15
1.24

-10
1.38

COP (ASHRAE)
Comp.\C
TL4F

-35
0.64

12

13
14

W/W

Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Static cooling, 220V 50Hz,
PTC consumption incl.

EN 12900/CECOMAF
55C
32C
55C

Main winding

ASHRAE
55C
32C
32C

Winding protector Start winding

LST
g

b
8217

a1

Accessories
Devices

Fig.

TL4F

a1

103N0011
103N0018

Starting relay

a2

117U6009

PTC starting device

6.3 mm spades
4.8 mm spades

Main winding a1 Start winding


N

Cover

103N2010

Starting capacitor 60 F

117U5014

Cord relief

103N1010

Protection screen for PTC

103N0476

Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities

August 2001

118-1917
118-1918
118-1919

Winding protector

CD.42.Z2.02

CK.40.B6.02

June 2001

25

TL5F
Standard Compressor
R134a
220-240V 50Hz
Data Sheet (Replaces CG.42.B1.02)
General
TL5F

Code number

102G4501

102G

TL5F
Application

R134a

Blue stripe
Approvals

Application
Application
Evaporating temperature range
Voltage range

C
V/Hz

LBP

Barcode on
white background

-35 to -10

Yellow background

4501

8271

Compressor

DANFOSS COMPRESSORS

198 - 254 /50

Motor type

RSIR/CSIR

Max. ambient temperature


Comp. cooling at ambient temp.

38

32C

38C

S
O
F1
F2

= Static cooling normally sufficient


= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

Design
Displacement

cm3

Oil quantity

cm3

180

400

cm3

1790

kg

7.5

Maximum refrigerant charge


Free gas vol. in compressor
Weight without electrical equipment

5.08

16

Motor
watt

110

alternative motor

125

LRA (rated after 4 sec. UL984) LST/HST

4.3/5.1

alternative motor
Cut-in current LST/HST

35
70
100

Motor size

4.7/5.8
A

8.6/5.1

alternative motor

170
178
186
204

8.7/5.8

Resistance, main and start winding (25C)

18.2/15.1

alternative motor

16.0/17.0

Approvals

C or
D

EN 60335-2-34 with Annex AA, CCIB


30

31.5
28

169

6.2 0.09

Process connector

location/I.D. mm

6.2 0.09

Discharge connector

location/I.D. mm

5.0 +0.12/+0.20

Compressors on a pallet

pcs.

125

8263

45

102

June 2001

26

CG.42.B2.02

CK.40.B6.02

71

B
location/I.D. mm

105
107

173

105

51 20

Suction connector

A B

mm

157
60.5
66

Height

29

Dimensions

D
C

or

222
176

96
117

August 2001

Capacity (EN 12900/CECOMAF)


Comp.\C
TL5F

-35
43

-30
60

-25
82

watt
-23.3
91

-20
110

-15
144

-10
183

HST
c

Capacity (ASHRAE)
Comp.\C
TL5F

-35
53

-30
74

watt
-25
101

-23.3
112

-20
136

-15
177

-10
226
b

Power consumption
Comp.\C
TL5F

-35
70

-30
85

watt
-25
101

-23.3
107

-20
118

-15
136

8219

-10
154

a2
d

Current consumption
Comp.\C
TL5F

-35
0.75

-30
0.78

A
-25
0.81

-23.3
0.83

-20
0.86

-15
0.91

-10
0.97

c
11

10

COP (EN 12900/CECOMAF)


Comp.\C
TL5F

-35
0.61

W/W

-30
0.70

-25
0.81

-23.3
0.85

-20
0.93

-15
1.06

-10
1.19

-30
0.86

-25
1.00

-23.3
1.05

-20
1.15

-15
1.30

-10
1.47

COP (ASHRAE)
Comp.\C
TL5F

-35
0.75

12

13
14

W/W

Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Static cooling, 220V 50Hz,
PTC consumption incl.

EN 12900/CECOMAF
55C
32C
55C

Main winding

ASHRAE
55C
32C
32C

Winding protector Start winding

LST
g

b
8217

a1

Accessories
Devices

Fig.

TL5F

a1

103N0011
103N0018

Starting relay

a2

117U6004

PTC starting device

6.3 mm spades
4.8 mm spades

Main winding a1 Start winding


N

Cover

103N2010

Starting capacitor 60 F

117U5014

Cord relief

103N1010

Protection screen for PTC

103N0476

Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities

August 2001

118-1917
118-1918
118-1919

Winding protector

CG.42.B2.02

CK.40.B6.02

June 2001

27

TLS4F
Standard Compressor
R134a
220-240V 50Hz
Data Sheet (Replaces CG.42.J3.02)
General
TLS4F

Code number

102G4425

Application

R134a
SUCTION
CONNECTOR

Blue stripe

Application
Application

LBP

Evaporating temperature range


Voltage range

-35 to -10

V/Hz

198 - 254 /50

Motor type

102G

TLS4F

4425

Approvals
Barcode on
white background

8272-4

Compressor

DANFOSS COMPRESSORS

Yellow background

RSIR/CSIR

Max. ambient temperature


Comp. cooling at ambient temp.

38

32C

38C

S
O
F1
F2

Design
3

Displacement

cm

Oil quantity

cm3

180

400

cm3

1600

kg

6.7

watt

85

Maximum refrigerant charge


Free gas vol. in compressor
Weight without electrical equipment

= Static cooling normally sufficient


= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

3.86

Motor
Motor size

80

LRA (rated after 4 sec. UL984) LST/HST

3.2/4.8

7.5/4.8

alternative motor
Cut-in current LST/HST

35
70
100

alternative motor

16

3.2/4.6

alternative motor

7.8/4.6

Resistance, main and start winding (25C)

170
178
186
204

25.7/16.3

alternative motor

26.8/13.5

Approvals

EN 60335-2-34 with Annex AA

222
176

E
Dimensions

6.2 0.09

location/I.D. mm

6.2 0.09

Discharge connector

location/I.D. mm

5.0 +0.12/+0.20
125

8244

45

102

May 2001

28

CG.42.J4.02

CK.40.B6.02

51 20

pcs.

157
60.5
66

Compressors on a pallet

71

location/I.D. mm

Process connector

105
107

Suction connector

A B

29

163
159

30

A
B

105

mm

31.5
28

Height

96
117

August 2001

Capacity (EN 12900/CECOMAF)


Comp.\C
TLS4F

-35
34.6

-30
51.5

-25
72.0

watt
-23.3
79.9

-20
96.8

-15
126

-10
162

HST
c

Capacity (ASHRAE)
Comp.\C
TLS4F

-35
42.6

-30
63.5

watt
-25
88.9

-23.3
98.6

-20
119

-15
156

-10
200
b

Power consumption
Comp.\C
TLS4F

-35
67.5

-30
77.8

watt
-25
89.0

-23.3
93.0

-20
101

-15
115

8219

-10
130

a2
d

Current consumption
Comp.\C
TLS4F

-35
0.59

-30
0.62

A
-25
0.66

-23.3
0.68

-20
0.71

-15
0.76

-10
0.81

c
11

10

COP (EN 12900/CECOMAF)


Comp.\C
TLS4F

-35
0.51

W/W

-30
0.66

-25
0.81

-23.3
0.86

-20
0.96

-15
1.10

-10
1.25

-30
0.82

-25
1.00

-23.3
1.06

-20
1.18

-15
1.36

-10
1.54

COP (ASHRAE)
Comp.\C
TLS4F

-35
0.63

12

13
14

W/W

Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Static cooling, 220V 50Hz

EN 12900/CECOMAF
55C
32C
55C

Main winding

ASHRAE
55C
32C
32C

Winding protector Start winding

LST
g

b
8217

a1

Accessories
Devices

Fig.

TLS4F

a1

103N0011
103N0018

Starting relay

a2

117U6009

PTC starting device

6.3 mm spades
4.8 mm spades

d
Main winding a1 Start winding
N

Cover

103N2010

Starting capacitor 60 F

117U5014

Cord relief

103N1010

Protection screen for PTC

103N0476

Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities

August 2001

118-1917
118-1918
118-1919

Winding protector

CG.42.J4.02

CK.40.B6.02

May 2001

29

TLS5F
Standard Compressor
R134a
220-240V 50Hz
Data Sheet (Replaces CD.42.K5.02)
General
TLS5F

Application

Code number

102G4520

Code number

102G4526

102G

TLS5F
R134a
SUCTION
CONNECTOR

Blue stripe

4520

Approvals

Application
Application

Barcode on
white background

LBP

Evaporating temperature range


Voltage range

198 - 254 /50

Motor type

RSIR/CSIR
C

38

32C

38C

Displacement

cm3

5.08

Oil quantity

cm3

180

400

cm3

1790

kg

7.3

Comp. cooling at ambient temp.

DANFOSS COMPRESSORS

Yellow background

-35 to -10

V/Hz

Max. ambient temperature

8272

Compressor

S
O
F1
F2

= Static cooling normally sufficient


= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

Design

Maximum refrigerant charge


Free gas vol. in compressor
Weight without electrical equipment

16

Motor size

watt

125

alternative motor

110

LRA (rated after 4 sec. UL984) LST/HST

4.7/5.8

alternative motor

4.3/5.1
A

170
178
186
204

8.7/5.8

alternative motor

8.6/5.1

Resistance, main and start winding (25C)

16.0/17.0

222
176

18.2/15.1
EN 60335-2-34 with Annex AA

31.5
28

173

169

Suction connector

location/I.D. mm

C 6.2 0.09

6.5 0.09

Process connector

location/I.D. mm

D 6.2 0.09

6.5 0.09

Discharge connector

location/I.D. mm

E 5.0 +0.12/+0.20

pcs.

5.0 +0.12/+0.20
125

105

45

Compressors on a pallet

8244

102

May 2001

30

CD.42.K6.02

CK.40.B6.02

51 20

mm

102G4526

157
60.5
66

Height

102G4520

105
107

A B

Dimensions

71

Approvals

29

alternative motor

30

Cut-in current LST/HST

35
70
100

Motor

96
117

August 2001

Capacity (EN 12900/CECOMAF)


Comp.\C
TLS5F

-35
47.8

-30
70.7

-25
98.0

watt
-23.3
109

-20
131

-15
170

-10
216

HST
c

Capacity (ASHRAE)
Comp.\C
TLS5F

-35
58.9

-30
87.2

watt
-25
121

-23.3
134

-20
161

-15
209

-10
267
b

Power consumption
Comp.\C
TLS5F

-35
82.7

-30
97.1

watt
-25
112

-23.3
117

-20
128

-15
144

8219

-10
162

a2
d

Current consumption
Comp.\C
TLS5F

-35
0.96

-30
0.98

A
-25
1.01

-23.3
1.02

-20
1.05

-15
1.10

-10
1.15

c
11

10

COP (EN 12900/CECOMAF)


Comp.\C
TLS5F

-35
0.58

W/W

-30
0.73

-25
0.88

-23.3
0.93

-20
1.02

-15
1.18

-30
0.90

-25
1.08

-23.3
1.14

-20
1.26

-15
1.45

COP (ASHRAE)
Comp.\C
TLS5F

-35
0.71

-10
1.33

12

13
14

W/W

Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Static cooling, 220V 50Hz,
PTC consumption incl.

EN 12900/CECOMAF
55C
32C
55C

-10
1.65

Main winding

ASHRAE
55C
32C
32C

Winding protector Start winding

LST
g

b
8217

a1

Accessories
Devices

Fig.

TLS5F

a1

103N0011
103N0018

Starting relay

a2

117U6004

PTC starting device

6.3 mm spades
4.8 mm spades

d
Main winding a1 Start winding
N

Cover

103N2010

Starting capacitor 60 F

117U5014

Cord relief

103N1010

Protection screen for PTC

103N0476

Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities

August 2001

118-1917
118-1918
118-1919

Winding protector

CD.42.K6.02

CK.40.B6.02

May 2001

31

TLS6F
Standard Compressor
R134a
220-240V 50Hz
Data Sheet (Replaces CG.42.G1.02)
General
TLS6F

Code number

102G4620

Application

R134a
SUCTION
CONNECTOR

Blue stripe

Application

102G

TLS6F

4620

Approvals

Application

LBP

Evaporating temperature range


Voltage range

-35 to -10

V/Hz

Barcode on
white background

8272-2

Compressor

DANFOSS COMPRESSORS

Yellow background

198 - 254 /50

Motor type

RSIR/CSIR

Max. ambient temperature


Comp. cooling at ambient temp.

38

32C

38C

S
O
F1
F2

= Static cooling normally sufficient


= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

Design
Displacement

cm3

Oil quantity

cm3

180

400

cm3

1790

kg

7.3

Maximum refrigerant charge


Free gas vol. in compressor
Weight without electrical equipment

5.70

16

Motor
watt

125

alternative motor

110

LRA (rated after 4 sec. UL984) LST/HST

4.7/5.8

alternative motor
Cut-in current LST/HST

35
70
100

Motor size

4.3/5.1
A

8.7/5.8

alternative motor

170
178
186
204

8.6/5.1

Resistance, main and start winding (25C)

16.0/17.0

alternative motor

18.2/15.1

222
176

EN 60335-2-34 with Annex AA

31.5
28

30

Approvals

169

6.2 0.09

Process connector

location/I.D. mm

6.2 0.09

Discharge connector

location/I.D. mm

5.0 +0.12/+0.20

Compressors on a pallet

pcs.

125

8244

45

102

June 2001

32

CG.42.G2.02

CK.40.B6.02

71

B
location/I.D. mm

105
107

173

105

51 20

Suction connector

A B

mm

157
60.5
66

Height

29

Dimensions

96
117

August 2001

Capacity (EN 12900/CECOMAF)


Comp.\C
TLS6F

-35
58

-30
77

-25
104

watt
-23.3
115

-20
139

-15
183

-10
235

HST
c

Capacity (ASHRAE)
Comp.\C
TLS6F

-35
71

-30
95

watt
-25
128

-23.3
142

-20
172

-15
226

-10
290
b

Power consumption
Comp.\C
TLS6F

-35
84

-30
101

watt
-25
119

-23.3
125

-20
138

-15
159

8219

-10
181

a2
d

Current consumption
Comp.\C
TLS6F

-35
0.78

-30
0.82

A
-25
0.86

-23.3
0.88

-20
0.92

-15
0.99

-10
1.08

c
11

10

COP (EN 12900/CECOMAF)


Comp.\C
TLS6F

-35
0.69

W/W

-30
0.76

-25
0.87

-23.3
0.92

-20
1.01

-15
1.15

-30
0.94

-25
1.08

-23.3
1.13

-20
1.24

-15
1.42

COP (ASHRAE)
Comp.\C
TLS6F

-35
0.85

-10
1.30

12

13
14

W/W

Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Static cooling, 220V 50Hz,
PTC consumption incl.

EN 12900/CECOMAF
55C
32C
55C

-10
1.60

Main winding

ASHRAE
55C
32C
32C

Winding protector Start winding

LST
g

b
8217

a1

Accessories
Devices

Fig.

TLS6F

a1

103N0011
103N0018

Starting relay

a2

117U6004

PTC starting device

6.3 mm spades
4.8 mm spades

d
Main winding a1 Start winding
N

Cover

103N2010

Starting capacitor 60 F

117U5014

Cord relief

103N1010

Protection screen for PTC

103N0476

Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities

August 2001

118-1917
118-1918
118-1919

Winding protector

CG.42.G2.02

CK.40.B6.02

June 2001

33

TLS7F
Standard Compressor
R134a
220-240V 50Hz
Data Sheet (Replaces CG.42.H1.02)
General
TLS7F

Code number

102G4720

Application

R134a
SUCTION
CONNECTOR

Blue stripe

Application

102G

TLS7F

4720

Approvals

Application

LBP

Evaporating temperature range


Voltage range

-35 to -10

V/Hz

Barcode on
white background

8272-3

Compressor

DANFOSS COMPRESSORS

Yellow background

198 - 254 /50

Motor type

RSIR/CSIR

Max. ambient temperature

Comp. cooling at ambient temp.

38*

32C

38C

S
O
F1

* run capacitor 4 F compulsory in 38C ambient temperature

F2

= Static cooling normally sufficient


= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

Design
Displacement

cm3

Oil quantity

cm3

180

400

cm3

1790

kg

7.5

Maximum refrigerant charge


Free gas vol. in compressor
Weight without electrical equipment

6.49

16

Motor
watt

LRA (rated after 4 sec. UL984) LST/HST

140

5.4/5.7

Cut-in current LST/HST

9.7/5.7

Resistance, main and start winding (25C)

14.5/14.8

Dimensions
Height

mm

173

169

location/I.D. mm

6.2 0.09

Process connector

location/I.D. mm

6.2 0.09

Discharge connector

location/I.D. mm

5.0 +0.12/+0.20

170
178
186
204

222
176

31.5
28

Suction connector

EN 60335-2-34 with Annex AA

30

Approvals

35
70
100

Motor size

Compressors on a pallet

pcs.

105

105
107

A B

125

102

June 2001

34

CG.42.H2.02

CK.40.B6.02

71

29

51 20

45

157
60.5
66

8244

96
117

August 2001

Capacity (EN 12900/CECOMAF)


Comp.\C
TLS7F

-35
66

-30
89

watt

-25
120

-23.3
133

-20
160

-15
208

-10
264

-25
148

-23.3
163

-20
197

-15
256

-10
326

Capacity (ASHRAE)
Comp.\C
TLS7F

-35
81

-30
109

HST
c

watt

Power consumption
Comp.\C
TLS7F

-35
97

-30
116

8219

watt
-25
136

-23.3
143

-20
158

-15
182

a2

-10
207
d

Current consumption
Comp.\C
TLS7F

-35
0.87

-30
0.91

A
-25
0.96

-23.3
0.98

-20
1.03

-15
1.11

-10
1.20

c
11

10

COP (EN 12900/CECOMAF)


Comp.\C
TLS7F

-35
0.68

W/W

-30
0.77

-25
0.88

-23.3
0.92

-20
1.01

-15
1.14

-30
0.94

-25
1.09

-23.3
1.14

-20
1.24

-15
1.41

COP (ASHRAE)
Comp.\C
TLS7F

-35
0.84

12

-10
1.28

W/W

Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Static cooling, 220V 50Hz,
PTC consumption incl.

EN 12900/CECOMAF
55C
32C
55C

Main winding

-10
1.57

ASHRAE
55C
32C
32C

Winding protector Start winding

LST
g

Accessories

Devices

Fig.

TLS7F

PTC starting device

6.3 mm spades
4.8 mm spades

a1

103N0011
103N0018

PTC starting device

6.3 mm spades
a1**
4.8 mm spades

103N0016*
103N0021*

Starting relay

a2

Cover

103N2010

117U5014

Cord relief

103N1010

Protection screen for PTC

g
6.3 mm spades
4.8 mm spades

Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities

8217

a1
d
Main winding a1 Start winding

117U6000

Starting capacitor 60 F

Run capacitor 4 F

13
14

103N0476

117-7117*
117-7119*
118-1917
118-1918
118-1919

Winding protector

* run capacitor 4 F compulsory in 38C ambient


temperature
** with connector for RC

August 2001

CG.42.H2.02

CK.40.B6.02

June 2001

35

NL6F
Standard Compressor
R134a
220-240V 50Hz
Data Sheet (Replaces CD.43.P4.02)
General
NL6F

Code number

105G6606

105G

NL6F
Application

R134a

Blue stripe
Approvals

Application
Application
Evaporating temperature range
Voltage range

C
V/Hz

LBP

Barcode on
white background

-35 to -10

Yellow background

6606

DANFOSS COMPRESSORS

8273-2

Compressor

198 - 254 /50

Motor type

RSIR/CSIR

Max. ambient temperature


Comp. cooling at ambient temp.

38

32C

38C

S
O
F1
F2

= Static cooling normally sufficient


= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

Design
Displacement

cm3

Oil quantity

cm3

320

400

cm3

2130

kg

9.3

Maximum refrigerant charge


Free gas vol. in compressor
Weight without electrical equipment

6.13

204
170

Motor
watt

LRA (rated after 4 sec. UL984) LST/HST

125

5.0/5.0

Cut-in current LST/HST

9.6/5.0

Resistance, main and start winding (25C)

16.0/13.6

Approvals

100
70

Motor size

16

EN 60335-2-34 with Annex AA

178

205

Dimensions

6.2 0.09

Process connector

location/I.D. mm

6.2 0.09

Discharge connector

location/I.D. mm

5.0 +0.12/+0.20

Compressors on a pallet

pcs.

A B

102.5

183

80

75.5

B
location/I.D. mm

25

190

15

35

Suction connector

C
mm

93.5

Height

254

113

July 2001

36

CD.43.P5.02

CK.40.B6.02

27

47

54
78

51

72

166

60.5

8248

119
127

August 2001

Capacity (EN 12900/CECOMAF)


Comp.\C
NL6F

-35
52

-30
77

-25
110

watt
-23.3
123

-20
151

-15
200

-10
258

HST
c

Capacity (ASHRAE)
Comp.\C
NL6F

-35
64

-30
95

watt
-25
135

-23.3
151

-20
186

-15
247

-10
318
b

Power consumption
Comp.\C
NL6F

-35
80

-30
98

watt
-25
118

-23.3
125

-20
139

-15
161

8219

-10
185

a2
d

Current consumption
Comp.\C
NL6F

-35
0.78

-30
0.81

A
-25
0.86

-23.3
0.88

-20
0.92

-15
0.99

-10
1.08

c
11

10

COP (EN 12900/CECOMAF)


Comp.\C
NL6F

-35
0.65

W/W

-30
0.78

-25
0.93

-23.3
0.99

-20
1.09

-15
1.24

-30
0.96

-25
1.15

-23.3
1.21

-20
1.34

-15
1.53

COP (ASHRAE)
Comp.\C
NL6F

-35
0.80

-10
1.39

12

13
14

W/W

Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Static cooling, 220V 50Hz,
PTC consumption incl.

EN 12900/CECOMAF
55C
32C
55C

-10
1.72

Main winding

ASHRAE
55C
32C
32C

Winding protector Start winding

LST
g

b
8217

a1

Accessories
Devices

Fig.

NL6F

a1

103N0011
103N0018

Starting relay

a2

117U6004
103N2010

PTC starting device

6.3 mm spades
4.8 mm spades

Cover

Starting capacitor 80 F

117U5015

Cord relief

103N1010

Protection screen for PTC

103N0476

Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities

August 2001

d
Main winding a1 Start winding
N

118-1917
118-1918
118-1919

Winding protector

CD.43.P5.02

CK.40.B6.02

July 2001

37

NL7F
Standard Compressor
R134a
220-240V 50Hz
Data Sheet (Replaces CG.43.K1.02)
General
NL7F

Code number

105G6706

Code number compressor with oil cooler

105G6716

105G

NL7F
Application

R134a

Blue stripe
Approvals

6706

Barcode on
white background

Application
Application

LBP

Evaporating temperature range


Voltage range

-35 to -10

V/Hz

198 - 254 /50

Motor type

RSIR/CSIR

Max. ambient temperature

38

32C

38C

Displacement

cm3

7.27

Oil quantity

cm3

320

400

cm3

2180

kg

9.6

Comp. cooling at ambient temp.

DANFOSS COMPRESSORS

Yellow background

8273-4

Compressor

S
O
F1
F2

= Static cooling normally sufficient


= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

Design

Maximum refrigerant charge


Free gas vol. in compressor
Weight without electrical equipment

204
170

Motor
watt

LRA (rated after 4 sec. UL984) LST/HST

150

5.9/5.9

Cut-in current LST/HST

10.4/5.9

Resistance, main and start winding (25C)

13.3/14.1

Approvals

100
70

Motor size

EN 60335-2-34 with Annex AA, CCIB

16
178
205

E
C

183

6.2 0.09

Process connector

location/I.D. mm

6.2 0.09

Discharge connector

location/I.D. mm

5.0 +0.12/+0.20

Oil cooler

location/I.D. mm

5.0 +0.12/+0.20

A B

40
102.5
75.5

190

93.5

location/I.D. mm

15

Suction connector

mm

35

Height

25

Dimensions

254

F
8249

72

51

113

August 2001

38

CG.43.K2.02

CK.40.B6.02

27

47

40
54
78

80
60.5

pcs.

166

Compressors on a pallet

119
127

August 2001

Capacity (EN 12900/CECOMAF)


Comp.\C
NL7F

-35
71

-30
99

-25
136

watt
-23.3
151

-20
182

-15
238

-10
303

HST
c

Capacity (ASHRAE)
Comp.\C
NL7F

-35
87

-30
122

watt
-25
167

-23.3
186

-20
225

-15
293

-10
374
b

Power consumption
Comp.\C
NL7F

-35
97

-30
121

watt
-25
146

-23.3
155

-20
173

-15
201

8219

-10
232

a2
d

Current consumption
Comp.\C
NL7F

-35
0.92

-30
0.96

A
-25
1.02

-23.3
1.04

-20
1.10

-15
1.20

-10
1.33

c
11

10

COP (EN 12900/CECOMAF)


Comp.\C
NL7F

-35
0.73

W/W

-30
0.82

-25
0.93

-23.3
0.97

-20
1.06

-15
1.18

-10
1.31

-30
1.01

-25
1.15

-23.3
1.20

-20
1.30

-15
1.46

-10
1.61

COP (ASHRAE)
Comp.\C
NL7F

-35
0.90

12

13
14

W/W

Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Static cooling, 220V 50Hz,
PTC consumption incl.

EN 12900/CECOMAF
55C
32C
55C

Main winding

ASHRAE
55C
32C
32C

Winding protector Start winding

LST
g

b
8217

a1

Accessories
Devices

Fig.

NL7F

a1

103N0011
103N0018

Starting relay

a2

117U6000
103N2010

PTC starting device

6.3 mm spades
4.8 mm spades

Cover

Starting capacitor 80 F

117U5015

Cord relief

103N1010

Protection screen for PTC

103N0476

Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities

August 2001

d
Main winding a1 Start winding
N

118-1917
118-1918
118-1919

Winding protector

CG.43.K2.02

CK.40.B6.02

August 2001

39

NL8F
Standard Compressor
R134a
220-240V 50Hz
Data Sheet (Replaces CD.43.J5.02)
General
NL8F

Code number

105G6822

Application
Application

LBP

Evaporating temperature range


Voltage range

-35 to -10

V/Hz

105G

NL8F
Application

R134a

Blue stripe
Approvals

6822

Barcode on
white background

DANFOSS COMPRESSORS

Yellow background

8273-5

Compressor

198 - 254 /50

Motor type

RSIR/CSIR

Max. ambient temperature


Comp. cooling at ambient temp.

38

32C

38C

S
O
F1
F2

= Static cooling normally sufficient


= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

Design
Displacement

cm3

7.95

Oil quantity

cm3

320

Maximum refrigerant charge


Free gas vol. in compressor
Weight without electrical equipment

400

cm3

2230

kg

9.8
204
170

Motor
watt

LRA (rated after 4 sec. UL984) LST/HST

175

6.6/7.9

Cut-in current LST/HST

10.9/7.9

Resistance, main and start winding (25C)

10.7/13.0

Approvals

100
70

Motor size

16

EN 60335-2-34 with Annex AA

178

205

Dimensions

6.2 0.09

Process connector

location/I.D. mm

6.2 0.09

Discharge connector

location/I.D. mm

5.0 +0.12/+0.20

Compressors on a pallet

pcs.

A B

102.5

191

80

75.5

B
location/I.D. mm

25

197

15

35

Suction connector

C
mm

93.5

Height

254

113

June 2001

40

CD.43.J6.02

CK.40.B6.02

27

47

54
78

51

72

166

60.5

8248

119
127

August 2001

Capacity (EN 12900/CECOMAF)


Comp.\C
NL8F

-35
82

-30
112

-25
149

watt
-23.3
163

-20
194

-15
249

-10
317

HST
c

Capacity (ASHRAE)
Comp.\C
NL8F

-35
101

-30
139

watt
-25
184

-23.3
201

-20
240

-15
308

-10
392
b

Power consumption
Comp.\C
NL8F

-35
116

-30
134

watt
-25
154

-23.3
162

-20
177

-15
203

8219

-10
232

a2
d

Current consumption
Comp.\C
NL8F

-35
0.92

-30
0.98

A
-25
1.04

-23.3
1.07

-20
1.13

-15
1.22

-10
1.34

c
11

10

COP (EN 12900/CECOMAF)


Comp.\C
NL8F

-35
0.70

W/W

-30
0.84

-25
0.97

-23.3
1.01

-20
1.09

-15
1.23

-30
1.04

-25
1.19

-23.3
1.25

-20
1.35

-15
1.52

COP (ASHRAE)
Comp.\C
NL8F

-35
0.87

-10
1.37

12

13
14

W/W

Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Static cooling, 220V 50Hz,
PTC consumption incl.

EN 12900/CECOMAF
55C
32C
55C

-10
1.69

Main winding

ASHRAE
55C
32C
32C

Winding protector Start winding

LST
g

b
8217

a1

Accessories
Devices

Fig.

NL8F

a1

103N0011
103N0018

Starting relay

a2

117U6001
103N2010

PTC starting device

6.3 mm spades
4.8 mm spades

Cover

Starting capacitor 80 F

117U5015

Cord relief

103N1010

Protection screen for PTC

103N0476

Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities

August 2001

d
Main winding a1 Start winding
N

118-1917
118-1918
118-1919

Winding protector

CD.43.J6.02

CK.40.B6.02

June 2001

41

NL9F
Standard Compressor
R134a
220-240V 50Hz
Data Sheet (Replaces CG.43.M1.02)
General
NL9F
105G6802

Code number

105G6804*)

Code number compressor with oil cooler

105G

NL9F

Code number

Application

R134a

Blue stripe
Approvals

105G6812
)

* Performance data established on 8.2 mm


suction line. Restrictions due to 6.2 mm
suction line can affect system performance.

6802

Barcode on
white background

8273

Compressor

DANFOSS COMPRESSORS

Yellow background

Application
Application

LBP

Evaporating temperature range


Voltage range

-35 to -10

V/Hz

S
O
F1

198 - 254 /50

Motor type

RSIR/CSIR

Max. ambient temperature


Comp. cooling at ambient temp.

38

32C

38C

= Static cooling normally sufficient


= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

F2

204
170

Design
Displacement

cm3

Oil quantity

cm3

320

400

cm3

2280

kg

10.0

Weight without electrical equipment

16

Motor
watt

A B

EN 60335-2-34 with Annex AA

105G6812
mm

A
B

8249

191

location/I.D. mm

C 8.2 0.09

8.2 0.09

Process connector

location/I.D. mm

D 6.2 0.09

6.2 0.09

6.2 0.09

Discharge connector

location/I.D. mm

E 6.2 0.09

6.2 0.09

5.0 +0.12/+0.20

Oil cooler

location/I.D. mm

F 6.2 0.09

August 2001

pcs.

197

Suction connector

Compressors on a pallet

254

105G6802 105G6804

80

CG.43.M2.02

CK.40.B6.02

6.2 0.09

166

Dimensions

40
102.5
75.5

10.7/13.0

25

10.9/7.9

15

Resistance, main and start winding (25C)

35

Cut-in current LST/HST

Approvals

42

6.6/7.9

93.5

60.5

LRA (rated after 4 sec. UL984) LST/HST

175

51

72

Motor size

Height

178
205

113

27

47

40
54
78

Free gas vol. in compressor

100
70

Maximum refrigerant charge

8.35

119
127

August 2001

Capacity (EN 12900/CECOMAF)


Comp.\C
NL9F

-35
80

-30
112

-25
155

watt
-23.3
172

-20
208

-15
272

-10
346

HST
c

Capacity (ASHRAE)
Comp.\C
NL9F

-35
98

-30
138

watt
-25
191

-23.3
212

-20
256

-15
335

-10
427
b

Power consumption
Comp.\C
NL9F

-35
117

-30
141

watt
-25
167

-23.3
176

-20
195

-15
225

8219

-10
257

a2
d

Current consumption
Comp.\C
NL9F

-35
0.92

-30
0.99

A
-25
1.08

-23.3
1.11

-20
1.18

-15
1.29

-10
1.41

c
11

10

COP (EN 12900/CECOMAF)


Comp.\C
NL9F

-35
0.68

W/W

-30
0.80

-25
0.93

-23.3
0.98

-20
1.07

-15
1.21

-10
1.35

-30
0.98

-25
1.14

-23.3
1.20

-20
1.32

-15
1.49

-10
1.66

COP (ASHRAE)
Comp.\C
NL9F

-35
0.84

12

13
14

W/W

Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Static cooling, 220V 50Hz,
PTC consumption incl.

EN 12900/CECOMAF
55C
32C
55C

Main winding

ASHRAE
55C
32C
32C

Winding protector Start winding

LST
g

b
8217

a1

Accessories
Devices

Fig.

NL9F

a1

103N0011
103N0018

Starting relay

a2

117U6001
103N2010

PTC starting device

6.3 mm spades
4.8 mm spades

Cover

Starting capacitor 80 F

117U5015

Cord relief

103N1010

Protection screen for PTC

103N0476

Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities

August 2001

Main winding a1 Start winding


N

118-1917
118-1918
118-1919

Winding protector

CG.43.M2.02

CK.40.B6.02

August 2001

43

NL11F
Standard Compressor
R134a
220-240V 50Hz
Data Sheet (Replaces CG.43.J1.02)
General
NL11F
105G6900

Code number

105G6901*)

Code number compressor with oil cooler

105G

NL11F

Code number

Application

R134a

Blue stripe
Approvals

105G6910
)

* Performance data established on 8.2 mm


suction line. Restrictions due to 6.2 mm
suction line can affect system performance.

6900

Barcode on
white background

8273-6

Compressor

DANFOSS COMPRESSORS

Yellow background

Application
Application

LBP

Evaporating temperature range


Voltage range

-35 to -10

V/Hz

S
O
F1

198 - 254 /50

Motor type

RSIR/CSIR

Max. ambient temperature

Comp. cooling at ambient temp.

= Static cooling normally sufficient


= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

38

32C

O/F1

38C

O/F1

F2

204
170

Design
Displacement

cm3

Oil quantity

cm3

320

400

cm3

2360

kg

10.7

Weight without electrical equipment

16

Motor

8.2/14.7
EN 60335-2-34 with Annex AA

105G6910
mm

105G6900 105G6901

197

C 8.2 0.09

8.2 0.09

Process connector

location/I.D. mm

D 6.2 0.09

6.2 0.09

6.2 0.09

Discharge connector

location/I.D. mm

E 6.2 0.09

6.2 0.09

5.0 +0.12/+0.20

Oil cooler

location/I.D. mm

F 6.2 0.09

August 2001

pcs.

F
8249

location/I.D. mm

Compressors on a pallet

254

203

80

CG.43.J2.02

CK.40.B6.02

6.2 0.09

166

Dimensions

Suction connector

A B

40
102.5
75.5

13.6/10.4

25

Resistance, main and start winding (25C)

15

Cut-in current LST/HST

35

9.2/10.4

Approvals

44

60.5

LRA (rated after 4 sec. UL984) LST/HST

235

93.5

watt

51

72

Motor size

Height

178
205

113

27

47

40
54
78

Free gas vol. in compressor

100
70

Maximum refrigerant charge

11.15

119
127

August 2001

Capacity (EN 12900/CECOMAF)


Comp.\C
NL11F

-35
102

-30
144

-25
200

watt
-23.3
223

-20
271

-15
356

-10
455

HST
c

Capacity (ASHRAE)
Comp.\C
NL11F

-35
125

-30
177

watt
-25
246

-23.3
274

-20
334

-15
438

-10
561
b

Power consumption
Comp.\C
NL11F

-35
146

-30
178

watt
-25
212

-23.3
224

-20
248

-15
286

8219

-10
325

a2
d

Current consumption
Comp.\C
NL11F

-35
1.40

-30
1.46

A
-25
1.54

-23.3
1.57

-20
1.64

-15
1.75

-10
1.89

c
11

10

COP (EN 12900/CECOMAF)


Comp.\C
NL11F

-35
0.70

W/W

-30
0.81

-25
0.94

-23.3
0.99

-20
1.09

-15
1.25

-10
1.40

-30
0.99

-25
1.16

-23.3
1.22

-20
1.34

-15
1.53

-10
1.73

COP (ASHRAE)
Comp.\C
NL11F

-35
0.86

12

13
14

W/W

Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Static cooling, 220V 50Hz,
PTC consumption incl.

EN 12900/CECOMAF
55C
32C
55C

Main winding

ASHRAE
55C
32C
32C

Winding protector Start winding

LST
g

b
8217

a1

Accessories
Devices

Fig.

NL11F

a1

103N0011
103N0018

Starting relay

a2

117U6002
103N2010

PTC starting device

6.3 mm spades
4.8 mm spades

Cover

Starting capacitor 80 F

117U5015

Cord relief

103N1010

Protection screen for PTC

103N0476

Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities

August 2001

d
Main winding a1 Start winding
N

118-1917
118-1918
118-1919

Winding protector

CG.43.J2.02

CK.40.B6.02

August 2001

45

NF7FX
Standard Compressor
R134a
220V 50/60Hz
Data Sheet (Replaces CD.43.W3.22)
General
NF7FX

Connector-material

Sealing

Copper-plated steel

Aluminium caps

Copper-plated steel

Rubber plugs

105G6743

Copper

Rubber plugs

105G6753

Application

105G

NF7FX

Code number
Blue stripe

R134a
SUCTION
CONNECTOR

6743

Barcode on
white background

DANFOSS COMPRESSORS

8340

Compressor

Yellow background

Application
Application

LBP/MBP

Evaporating temperature range

F (C)

Voltage range

-30 to 45 (-34.4 to 7.2)

V/Hz

198 - 242 /50


198 - 242 /60

Motor type

CSIR

Max. ambient temperature

F (C)

100 (38)

Comp. cooling at ambient temp.


90F (32C)

50Hz: S

60Hz: F1

100F (38C)

50Hz: F1

60Hz: F1

S
O
F1
F2

= Static cooling normally sufficient


= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

Design
cu.in. (cm3)

Free gas vol. in compressor housing fl.oz. (cm3)

79.7 (2360)

Weight without electrical equipment

23.0 (10.5)

lbs. (kg)

27

51

4.45"(113)

Motor

15.8

Resistance, main and start winding (77F)

5.8/12.6
-

Dimensions
Height

in. (mm) A

8.00 (203)

7.76 (197)

Suction connector

location/I.D. in. (mm) C 0.320-0.327 (8.20.09)

Process connector

location/I.D. in. (mm) D 0.252-0.259 (6.50.09)

Discharge connector

location/I.D. in. (mm) E

Compressors on a pallet

pcs.

0.252-0.259 (6.50.09)
80

A B

15

Approvals

E
C
35

Cut-in current HST

8.10"(205)

4.04"(102.5)

15.8

25

340

9.92"(252)
8.03"(204)
6.70"(170)

1.38"(35)

watt

4.69"(119)
5.00"(127)

3.68"(93.5)

LRA (rated after 4 sec.UL984) HST

5.20"(132)
4.00"(101.6)
2.76"(70)

Motor size

47

(54)

14.0 (400)

3.01"(78)

10.8 (320)

oz. (g)

Maximum refrigerant charge

2.97"(75.5)

fl.oz. (cm )

Oil quantity

2.13"

0.44 (7.27)

6.54"(166)
2.83"(72)
2.34" (59.5)

Displacement

8367

0.75"(19)
0.63"(16)
0.38"(9.7)
6.50"(165)
7.32"(186)

July 2001

46

CD.43.W4.22

CK.40.B6.02

August 2001

Capacity at LBP conditions (ASHRAE)


Comp.\F -30
Comp.\C -34.4
NF7FX
341

-20
-28.9
496

-13
-25
630

-10
-23.3
696

Btu/h

0
-17.8
943

10
-12.2
1255

20
-6.7
1630

30
-1.1
2086

40
4.4
2604

10
-12.2
1117

20
-6.7
1450

30
-1.1
1854

40
4.4
2312

45
7.2
2899

Capacity at MBP conditions (ASHRAE)


Comp.\F -30
Comp.\C -34.4
NF7FX
304

-20
-28.9
442

-13
-25
562

-10
-23.3
620

Btu/h

0
-17.8
840

45
7.2
2573

Capacity (EN 12900/CECOMAF)


Comp.\F -30
Comp.\C -34.4
NF7FX
82

-20
-28.9
119

-13
-25
151

-10
-23.3
167

-20
-28.9
158

0
-17.8
226

10
-12.2
301

20
-6.7
390

30
-1.1
498

40
4.4
622

-20
-28.9
1.73
-20
-28.9
3.13

-13
-25
176

-10
-23.3
184

0
-17.8
209

10
-12.2
235

20
-6.7
261

30
-1.1
287

40
4.4
314

45
7.2
327

-13
-25
1.76

-10
-23.3
1.78

0
-17.8
1.83

10
-12.2
1.89

20
-6.7
1.95

30
-1.1
2.02

40
4.4
2.10

45
7.2
2.14

-20
-28.9
2.80
-20
-28.9
0.75

Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Fan cooling F1, 220V 50Hz

a2

-13
-25
3.58

-10
-23.3
3.79

Btu/Wh
0
-17.8
4.52

10
-12.2
5.36

20
-6.7
6.27

30
-1.1
7.29

40
4.4
8.35

-13
-25
3.19

45
7.2
8.90

Btu/Wh

-10
-23.3
3.37

0
-17.8
4.02

10
-12.2
4.76

20
-6.7
5.56

30
-1.1
6.46

40
4.4
7.36

-10
-23.3
0.91

0
-17.8
1.08

10
-12.2
1.28

20
-6.7
1.49

30
-1.1
1.73

40
4.4
1.98

COP (EN 12900/CECOMAF)


Comp.\F -30
Comp.\C -34.4
NF7FX
0.61

EER at MBP conditions (ASHRAE)


Comp.\F -30
Comp.\C -34.4
NF7FX
2.27

dc

watt

EER at LBP conditions (ASHRAE)


Comp.\F -30
Comp.\C -34.4
NF7FX
2.55

8226

45
7.2
691

Current consumption
Comp.\F -30
Comp.\C -34.4
NF7FX
1.70

a2

watt

Power consumption
Comp.\F -30
Comp.\C -34.4
NF7FX
134

-13
-25
0.86

10
12

Main winding

11
13

Start winding
Thermostat

14

Motor protector

45
7.2
7.87

W/W

ASHRAE (LBP) ASHRAE (MBP)


130F (54.4C) 130F (54.4C)
90F (32C)
95F (35C)
90F (32C)
115F (46C)

45
7.2
2.11

EN12900/CECOMAF
55C (131F)
32C (90F)
55C (131F)

Accessories
Devices

Fig.

NF7FX

Starting relay (Klixon incl.)

a2

117U4140

Klixon

MRP59EN-6

Starting capacitor 125 F

117U5018

Cover

117U1023

Cord relief

117U0349

Cord relief capacitor

dc

117U0349

Mounting accessories
Bolt joint in quantities
Bolt joint in quantities
Snap-on in quantities

August 2001

in. (mm)
5
/8 (16)
3
/4 (19)
5
/8 (16)

118-1945
118-1948
118-1944

CD.43.W4.22

CK.40.B6.02

July 2001

47

NF9FX
Standard Compressor
R134a
220V 50Hz
Data Sheet (Replaces CD.43.Z1.22)
General
Sealing

Copper-plated steel

Aluminium caps

Copper-plated steel

Rubber plugs

Application
Blue stripe

Rubber plugs

Copper

Rubber plugs

R134a
SUCTION
CONNECTOR

105G6842 (UL-recognized)
105G6952* (UL-recognized)

Copper-plated steel

105G

NF9FX

Code number

6843

Barcode on
white background

105G6843

DANFOSS COMPRESSORS

Yellow background

105G6953*

LBP/MBP

198 - 242 /50

Motor type

CSIR

Max. ambient temperature

F (C)

100 (38)

Comp. cooling at ambient temp.

F2

90F (32C)

O/F1

100F (38C)

O/F1

Design
cu.in. (cm3)

Displacement

THERMALLY
PROTECTED
S
O
F1

0.51 (8.35)

fl.oz. (cm )

Oil quantity
Maximum refrigerant charge

10.8 (320)

oz. (g)

14.0 (400)

Free gas vol. in compressor housing fl.oz. (cm3)

79.7 (2360)

Weight without electrical equipment

23.0 (10.5)

lbs. (kg)

= Static cooling normally sufficient


Approval
= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

27

51

4.45"(113)

47

mark

(54)

V/Hz

1.57"
(40)

Voltage range

-30 to 45 (-34.4 to 7.2)

2.13"

F (C)

6.54"(166)
2.83"(72)
2.34" (59.5)

Evaporating temperature range

8340-6

NF9FX
220V-50Hz
1PH

* Oil cooler version

Application
Application

4.69"(119)
5.00"(127)

8.10"(205)

Motor

5.8/12.6

Approvals (105G6842, 105G6852)

UL984/CSA-C22.2

Approvals (105G6843, 105G6853)

A B

9.92"(252)
8.03"(204)
6.70"(170)

8.00 (203)

7.76 (197)

Suction connector

location/I.D. in. (mm) C 0.320-0.327 (8.20.09)

Process connector

location/I.D. in. (mm) D 0.252-0.259 (6.50.09)

Discharge connector

location/I.D. in. (mm) E

0.252-0.259 (6.50.09)

Oil cooler

location/I.D. in. (mm) F

0.252-0.259 (6.50.09)

Compressors on a pallet
July 2001

48

in. (mm) A

pcs.

80
CD.43.Z2.22

CK.40.B6.02

1.38"(35)

Height

5.20"(132)
4.00"(101.6)
2.76"(70)

Dimensions

2.97"(75.5)

15.8

Resistance, main and start winding (77F)

4.04"(102.5)

15.8

1.57"
(40)

Cut-in current HST

25

LRA (rated after 4 sec.UL984) HST

15

340

35

watt

3.68"(93.5)

Motor size

8340-2

NF9FX

Connector-material

3.01"(78)

Compressor

F
8336

0.75"(19)
0.63"(16)
0.38"(9.7)
6.50"(165)
7.32"(186)

August 2001

Capacity at LBP conditions (ASHRAE)


Comp.\F -30
Comp.\C -34.4
NF 9FX
389

-20
-28.9
562

-13
-25
712

-10
-23.3
786

Btu/h

0
-17.8
1061

10
-12.2
1409

20
-6.7
1825

30
-1.1
2331

40
4.4
2912

10
-12.2
1255

20
-6.7
1624

30
-1.1
2072

40
4.4
2586

45
7.2
3237

Capacity at MBP conditions (ASHRAE)


Comp.\F -30
Comp.\C -34.4
NF9FX
347

-20
-28.9
501

-13
-25
635

-10
-23.3
701

Btu/h

0
-17.8
945

45
7.2
2873

Capacity (EN 12900/CECOMAF)


Comp.\F -30
Comp.\C -34.4
NF9FX
94

-20
-28.9
135

-13
-25
171

-10
-23.3
189

-20
-28.9
180

0
-17.8
254

10
-12.2
337

20
-6.7
436

30
-1.1
557

40
4.4
694

-20
-28.9
1.77
-20
-28.9
3.13

-13
-25
200

-10
-23.3
209

0
-17.8
238

10
-12.2
269

20
-6.7
299

30
-1.1
330

40
4.4
361

45
7.2
377

-13
-25
1.81

-10
-23.3
1.83

0
-17.8
1.89

10
-12.2
1.97

20
-6.7
2.05

30
-1.1
2.14

40
4.4
2.24

45
7.2
2.29

-20
-28.9
2.78
-20
-28.9
0.75

Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Fan cooling F1, 220V 50Hz

a2

-13
-25
3.57

-10
-23.3
3.76

Btu/Wh
0
-17.8
4.46

10
-12.2
5.25

20
-6.7
6.12

30
-1.1
7.08

40
4.4
8.05

-13
-25
3.17

45
7.2
8.62

Btu/Wh

-10
-23.3
3.35

0
-17.8
3.97

10
-12.2
4.66

20
-6.7
5.43

30
-1.1
6.28

40
4.4
7.16

-10
-23.3
0.90

0
-17.8
1.07

10
-12.2
1.25

20
-6.7
1.46

30
-1.1
1.68

40
4.4
1.92

COP (EN 12900/CECOMAF)


Comp.\F -30
Comp.\C -34.4
NF9FX
0.62

EER at MBP conditions (ASHRAE)


Comp.\F -30
Comp.\C -34.4
NF9FX
2.30

dc

watt

EER at LBP conditions (ASHRAE)


Comp.\F -30
Comp.\C -34.4
NF9FX
2.57

8226

45
7.2
771

Current consumption
Comp.\F -30
Comp.\C -34.4
NF9FX
1.72

a2

watt

Power consumption
Comp.\F -30
Comp.\C -34.4
NF9FX
151

-13
-25
0.86

10
12

Main winding

11
13

Start winding
Thermostat

14

Motor protector

45
7.2
7.62

W/W

ASHRAE (LBP) ASHRAE (MBP)


130F (54.4C) 130F (54.4C)
90F (32C)
95F (35C)
90F (32C)
115F (46C)

45
7.2
2.04

EN12900/CECOMAF
55C (131F)
32C (90F)
55C (131F)

Accessories
Devices

Fig.

NF9FX

Starting relay (Klixon incl.)

a2

117U4140

Klixon

MRP59EN-6

Starting capacitor 125 F

Cover (105G6842, 105G6852)

117U1021

Cover (105G6843, 105G6853)

117U1023

117U5018

Cord relief

117U0349

Cord relief capacitor

dc

117U0349

Mounting accessories
Bolt joint in quantities
Bolt joint in quantities
Snap-on in quantities

August 2001

in. (mm)
5
/8 (16)
3
/4 (19)
5
/8 (16)

118-1945
118-1948
118-1944

CD.43.Z2.22

CK.40.B6.02

July 2001

49

NF10FX
Standard Compressor
R134a
220V 50Hz
Data Sheet (Replaces CG.43.A1.22)
General
NF10FX

Connector-material

Sealing

Copper-plated steel

Aluminium caps

Copper-plated steel

Rubber plugs

105G6847 (UL-recognized)

Copper-plated steel

Rubber plugs

105G6844

Copper

Rubber plugs

Application

105G

NF10FX

Code number
Blue stripe

R134a
SUCTION
CONNECTOR

6844

Barcode on
white background

8340-3

Compressor

DANFOSS COMPRESSORS

Yellow background
R

Application
LBP/MBP

Evaporating temperature range


Voltage range

NF10FX
220V-50Hz
1PH

-30 to 45 (-34.4 to 7.2)

F (C)
V/Hz

198 - 242 /50

Motor type

CSIR

Max. ambient temperature

F (C)

100 (38)

Comp. cooling at ambient temp.


90F (32C)

F1

100F (38C)

F2

8340-7

Application

THERMALLY
PROTECTED
S
O
F1
F2

= Static cooling normally sufficient


Approval
= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

mark

Design
cu.in. (cm3)

Free gas vol. in compressor housing fl.oz. (cm3)

79.7 (2360)

Weight without electrical equipment

23.0 (10.5)

lbs. (kg)

27

51

4.45"(113)

450

LRA (rated after 4 sec.UL984) HST

20.0

Cut-in current HST

20.0
4.5/12.8
UL984/CSA-C22.2

Approvals (105G6844)

A B

15

Approvals (105G6847)

Dimensions
8.00 (203)

7.76 (197)

Suction connector

location/I.D. in. (mm) C 0.320-0.327 (8.20.09)

Process connector

location/I.D. in. (mm) D 0.252-0.259 (6.50.09)

Discharge connector

location/I.D. in. (mm) E

Compressors on a pallet

pcs.

0.252-0.259 (6.50.09)

9.92"(252)
8.03"(204)
6.70"(170)

1.38"(35)

in. (mm) A

5.20"(132)
4.00"(101.6)
2.76"(70)

Height

35

Resistance, main and start winding (77F)

8.10"(205)

4.04"(102.5)

watt

25

Motor size

4.69"(119)
5.00"(127)

3.68"(93.5)

Motor

47

(54)

14.0 (400)

3.01"(78)

10.8 (320)

oz. (g)

Maximum refrigerant charge

2.97"(75.5)

fl.oz. (cm )

Oil quantity

2.13"

0.62 (10.09)

6.54"(166)
2.83"(72)
2.34" (59.5)

Displacement

8367

0.75"(19)
0.63"(16)
0.38"(9.7)

80
6.50"(165)
7.32"(186)

July 2001

50

CG.43.A2.22

CK.40.B6.02

August 2001

Capacity at LBP conditions (ASHRAE)


Comp.\F -30
Comp.\C -34.4
NF10FX
449

-20
-28.9
648

-13
-25
821

-10
-23.3
905

Btu/h

0
-17.8
1222

10
-12.2
1623

20
-6.7
2104

30
-1.1
2693

40
4.4
3374

10
-12.2
1445

20
-6.7
1872

30
-1.1
2394

40
4.4
2996

45
7.2
3759

Capacity at MBP conditions (ASHRAE)


Comp.\F -30
Comp.\C -34.4
NF10FX
400

-20
-28.9
578

-13
-25
732

-10
-23.3
807

Btu/h

0
-17.8
1089

45
7.2
3336

Capacity (EN 12900/CECOMAF)


Comp.\F -30
Comp.\C -34.4
NF10FX
108

-20
-28.9
156

-13
-25
197

-10
-23.3
217

-20
-28.9
248

0
-17.8
293

10
-12.2
389

20
-6.7
503

30
-1.1
643

40
4.4
804

-20
-28.9
2.70
-20
-28.9
2.61

-13
-25
272

-10
-23.3
283

0
-17.8
318

10
-12.2
354

20
-6.7
390

30
-1.1
426

40
4.4
462

45
7.2
481

-13
-25
2.73

-10
-23.3
2.75

0
-17.8
2.81

10
-12.2
2.88

20
-6.7
2.96

30
-1.1
3.05

40
4.4
3.15

45
7.2
3.21

-20
-28.9
2.33

-13
-25
3.02

-10
-23.3
3.20

Btu/Wh
0
-17.8
3.85

10
-12.2
4.60

20
-6.7
5.42

30
-1.1
6.34

40
4.4
7.33

-13
-25
2.69

45
7.2
7.86

Btu/Wh

-10
-23.3
2.85

0
-17.8
3.42

10
-12.2
4.08

20
-6.7
4.80

30
-1.1
5.62

40
4.4
6.49

-10
-23.3
0.77

0
-17.8
0.92

10
-12.2
1.10

20
-6.7
1.29

30
-1.1
1.51

40
4.4
1.74

COP (EN 12900/CECOMAF)


Comp.\F -30
Comp.\C -34.4
NF10FX
0.51

-20
-28.9
0.63

Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Fan cooling F1, 220V 50Hz

b
a2
c

EER at MBP conditions (ASHRAE)


Comp.\F -30
Comp.\C -34.4
NF10FX
1.87

dc

watt

EER at LBP conditions (ASHRAE)


Comp.\F -30
Comp.\C -34.4
NF10FX
2.09

8226

45
7.2
895

Current consumption
Comp.\F -30
Comp.\C -34.4
NF10FX
2.65

a2

watt

Power consumption
Comp.\F -30
Comp.\C -34.4
NF10FX
214

-13
-25
0.72

10
12

Main winding

11
13

Start winding
Thermostat

14

Motor protector

45
7.2
6.94

W/W

ASHRAE (LBP) ASHRAE (MBP)


130F (54.4C) 130F (54.4C)
90F (32C)
95F (35C)
90F (32C)
115F (46C)

45
7.2
1.86

EN12900/CECOMAF
55C (131F)
32C (90F)
55C (131F)

Accessories
Devices

Fig.

NF10FX

Starting relay (Klixon incl.)

a2

117U4139

Klixon

MRP59EN-6

Starting capacitor 125 F

Cover (105G6847)

117U1021

Cover (105G6844)

117U1023

117U5018

Cord relief

117U0349

Cord relief capacitor

dc

117U0349

Mounting accessories
Bolt joint in quantities
Bolt joint in quantities
Snap-on in quantities

August 2001

in. (mm)
5
/8 (16)
3
/4 (19)
5
/8 (16)

118-1945
118-1948
118-1944

CG.43.A2.22

CK.40.B6.02

July 2001

51

NF11FX
Standard Compressor
R134a
220V 50Hz
Data Sheet (Replaces CG.43.C1.22)
General
NF11FX

Connector-material

Sealing

Copper-plated steel

Aluminium caps

Copper-plated steel

Rubber plugs

Copper

Rubber plugs

Application

105G

NF11FX

Code number
Blue stripe

R134a
SUCTION
CONNECTOR

105G6944

6944

Barcode on
white background

DANFOSS COMPRESSORS

8340-4

Compressor

Yellow background

Application
Application

LBP/MBP

Evaporating temperature range

F (C)

Voltage range

-30 to 45 (-34.4 to 7.2)

V/Hz

198 - 242 /50

Motor type

CSIR
100 (38)

100F (38C)

F2

S
O
F1
F2

Design
Displacement

cu.in. (cm3)

0.68 (11.15)

Oil quantity

fl.oz. (cm3)

10.8 (320)

oz. (g)

14.0 (400)

Free gas vol. in compressor housing fl.oz. (cm3)

79.7 (2360)

Weight without electrical equipment

23.0 (10.5)

lbs. (kg)

Motor

27

51

4.45"(113)

watt

450

LRA (rated after 4 sec.UL984) HST

20.0

Cut-in current HST

7.76 (197)

location/I.D. in. (mm) C 0.320-0.327 (8.20.09)

Process connector

location/I.D. in. (mm) D 0.252-0.259 (6.50.09)

Discharge connector

location/I.D. in. (mm) E

0.252-0.259 (6.50.09)
80

25

4.04"(102.5)

B
Suction connector

9.92"(252)
8.03"(204)
6.70"(170)

1.38"(35)

8.00 (203)

3.68"(93.5)

in. (mm) A

15

Dimensions

A B

35

pcs.

4.5/12.8

Approvals

Compressors on a pallet

20.0

Resistance, main and start winding (77F)

Height

4.69"(119)
5.00"(127)

8.10"(205)

5.20"(132)
4.00"(101.6)
2.76"(70)

Motor size

47

2.97"(75.5)

Maximum refrigerant charge

= Static cooling normally sufficient


= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

(54)

F2

3.01"(78)

90F (32C)

2.13"

F (C)

Comp. cooling at ambient temp.

6.54"(166)
2.83"(72)
2.34" (59.5)

Max. ambient temperature

8367

0.75"(19)
0.63"(16)
0.38"(9.7)
6.50"(165)
7.32"(186)

July 2001

52

CG.43.C2.22

CK.40.B6.02

August 2001

Capacity at LBP conditions (ASHRAE)


Comp.\F -30
Comp.\C -34.4
NF11FX
496

-20
-28.9
713

-13
-25
901

-10
-23.3
993

Btu/h

0
-17.8
1336

10
-12.2
1768

20
-6.7
2280

30
-1.1
2907

40
4.4
3637

10
-12.2
1575

20
-6.7
2029

30
-1.1
2584

40
4.4
3230

45
7.2
4051

Capacity at MBP conditions (ASHRAE)


Comp.\F -30
Comp.\C -34.4
NF11FX
442

-20
-28.9
636

-13
-25
803

-10
-23.3
885

Btu/h

0
-17.8
1190

45
7.2
3595

Capacity (EN 12900/CECOMAF)


Comp.\F -30
Comp.\C -34.4
NF11FX
119

-20
-28.9
171

-13
-25
216

-10
-23.3
238

-20
-28.9
266

0
-17.8
320

10
-12.2
423

20
-6.7
545

30
-1.1
694

40
4.4
867

-20
-28.9
2.72
-20
-28.9
2.68

-13
-25
291

-10
-23.3
302

0
-17.8
341

10
-12.2
383

20
-6.7
426

30
-1.1
470

40
4.4
512

45
7.2
533

-13
-25
2.76

-10
-23.3
2.78

0
-17.8
2.85

10
-12.2
2.94

20
-6.7
3.05

30
-1.1
3.17

40
4.4
3.29

45
7.2
3.36

-20
-28.9
2.39
-20
-28.9
0.64

Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Fan cooling F2, 220V 50Hz

a2

-13
-25
3.10

-10
-23.3
3.29

Btu/Wh
0
-17.8
3.92

10
-12.2
4.62

20
-6.7
5.35

30
-1.1
6.18

40
4.4
7.10

-13
-25
2.76

45
7.2
7.60

Btu/Wh

-10
-23.3
2.93

0
-17.8
3.49

10
-12.2
4.11

20
-6.7
4.76

30
-1.1
5.50

40
4.4
6.31

-10
-23.3
0.79

0
-17.8
0.94

10
-12.2
1.10

20
-6.7
1.28

30
-1.1
1.48

40
4.4
1.69

COP (EN 12900/CECOMAF)


Comp.\F -30
Comp.\C -34.4
NF11FX
0.50

EER at MBP conditions (ASHRAE)


Comp.\F -30
Comp.\C -34.4
NF11FX
1.87

dc

watt

EER at LBP conditions (ASHRAE)


Comp.\F -30
Comp.\C -34.4
NF11FX
2.10

8226

45
7.2
965

Current consumption
Comp.\F -30
Comp.\C -34.4
NF11FX
2.68

a2

watt

Power consumption
Comp.\F -30
Comp.\C -34.4
NF11FX
236

-13
-25
0.74

10
12

Main winding

11
13

Start winding
Thermostat

14

Motor protector

45
7.2
6.75

W/W

ASHRAE (LBP) ASHRAE (MBP)


130F (54.4C) 130F (54.4C)
90F (32C)
95F (35C)
90F (32C)
115F (46C)

45
7.2
1.81

EN12900/CECOMAF
55C (131F)
32C (90F)
55C (131F)

Accessories
Devices

Fig.

NF11FX

Starting relay (Klixon incl.)

a2

117U4139
MRP59EN-6

Klixon
Starting capacitor 125 F

117U5018

Cover

117U1023

Cord relief

117U0349

Cord relief capacitor

dc

117U0349

Mounting accessories
Bolt joint in quantities
Bolt joint in quantities
Snap-on in quantities

August 2001

in. (mm)
5
/8 (16)
3
/4 (19)
5
/8 (16)

118-1945
118-1948
118-1944

CG.43.C2.22

CK.40.B6.02

July 2001

53

FR7.5F
Standard Compressor
R134a
220-240V 50Hz
Data Sheet (Replaces CD.43.A7.02)
General
FR7.5F

Code number

103G6750

103G

FR7.5F
Application

R134a

Blue stripe
Approvals

Application
Application
Evaporating temperature range
Voltage range

C
V/Hz

LBP

Barcode on
white background

-35 to -10

Yellow background

6750

8274

Compressor

DANFOSS COMPRESSORS

198 - 254 /50

Motor type

RSIR/CSIR

Max. ambient temperature


Comp. cooling at ambient temp.

38

32C

38C

S
O
F1
F2

= Static cooling normally sufficient


= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

Design
Displacement

cm3

Oil quantity

cm3

350

900

cm3

1450

kg

10.6

Maximum refrigerant charge


Free gas vol. in compressor
Weight without electrical equipment

6.93

204
178

16

19

Motor
150
6.1/7.4

Cut-in current LST/HST

10.9/7.4

Resistance, main and start winding (25C)

12.6/12.4

Approvals

8.2 0.09

Process connector

location/I.D. mm

6.2 0.09

Discharge connector

location/I.D. mm

6.2 0.09

pcs.

A B
102
130

191

location/I.D. mm

30

B
Suction connector

C
E

196

25

30

mm

Compressors on a pallet

127
165
170
186
200

127

Height

9.7

EN 60335-2-34 with Annex AA

Dimensions

35
127
150

80

122.5

June 2001

54

CD.43.A8.02

CK.40.B6.02

8253

24

40

40

55

156

243

32
55

watt

LRA (rated after 4 sec. UL984) LST/HST

101.6
70
60.5

Motor size

124.5
127.5

August 2001

Capacity (EN 12900/CECOMAF)


Comp.\C
FR7.5F

-35
60

-30
79

-25
108

watt
-23.3
120

-20
147

-15
197

-10
257

HST
c

Capacity (ASHRAE)
Comp.\C
FR7.5F

-35
74

watt

-30
97

-25
133

-23.3
148

-20
182

-15
243

-10
317
b

Power consumption
Comp.\C
FR7.5F

-35
89

watt

-30
106

-25
126

-23.3
133

-20
148

-15
173

8219

-10
200

a2
d

Current consumption
Comp.\C
FR7.5F

-35
0.80

-30
0.85

A
-25
0.91

-23.3
0.94

-20
0.99

-15
1.09

-10
1.20

c
11

10

COP (EN 12900/CECOMAF)


Comp.\C
FR7.5F

-35
0.68

W/W

-30
0.74

-25
0.86

-23.3
0.90

-20
0.99

-15
1.14

-10
1.29

-30
0.91

-25
1.05

-23.3
1.11

-20
1.22

-15
1.40

-10
1.59

COP (ASHRAE)
Comp.\C
FR7.5F

-35
0.83

12

13
14

W/W

Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Static cooling, 220V 50Hz,
PTC consumption incl.

EN 12900/CECOMAF
55C
32C
55C

Main winding

ASHRAE
55C
32C
32C

Winding protector Start winding

LST
g

b
8217

a1

Accessories
Devices

Fig.

FR7.5F

a1

103N0011
103N0018

Starting relay

a2

117U6000
103N2010

PTC starting device

6.3 mm spades
4.8 mm spades

Main winding a1 Start winding


N

Cover

Starting capacitor 80 F

117U5015

Cord relief

103N1010

Protection screen for PTC

103N0476

Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities

August 2001

118-1917
118-1918
118-1919

Winding protector

CD.43.A8.02

CK.40.B6.02

June 2001

55

FR8.5F
Standard Compressor
R134a
220-240V 50Hz
Data Sheet (Replaces CG.43.G1.02)
General
FR8.5F

Code number

103G6850

103G

FR8.5F
Application

R134a

Blue stripe
Approvals

Application
Application
Evaporating temperature range
Voltage range

C
V/Hz

LBP

Barcode on
white background

-35 to -10

Yellow background

6850

8274-2

Compressor

DANFOSS COMPRESSORS

198 - 254 /50

Motor type

RSIR/CSIR

Max. ambient temperature


Comp. cooling at ambient temp.

38

32C

38C

S
O
F1
F2

= Static cooling normally sufficient


= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

Design
Displacement

cm3

Oil quantity

cm3

350

900

cm3

1450

kg

10.6

Maximum refrigerant charge


Free gas vol. in compressor
Weight without electrical equipment

7.95

204
178

16

19

Motor
175
6.8/8.1

Cut-in current LST/HST

11.4/8.1

Resistance, main and start winding (25C)

10.7/13.0

Approvals

8.2 0.09

Process connector

location/I.D. mm

6.2 0.09

Discharge connector

location/I.D. mm

6.2 0.09

pcs.

A B
102
130

191

location/I.D. mm

30

B
Suction connector

C
E

196

25

30

mm

Compressors on a pallet

127
165
170
186
200

127

Height

9.7

EN 60335-2-34 with Annex AA

Dimensions

35
127
150

80

122.5

June 2001

56

CG.43.G2.02

CK.40.B6.02

8253

24

40

40

55

156

243

32
55

watt

LRA (rated after 4 sec. UL984) LST/HST

101.6
70
60.5

Motor size

124.5
127.5

August 2001

Capacity (EN 12900/CECOMAF)


Comp.\C
FR8.5F

-35
65

-30
89

-25
124

watt
-23.3
138

-20
169

-15
224

-10
289

HST
c

Capacity (ASHRAE)
Comp.\C
FR8.5F

-35
80

watt

-30
110

-25
153

-23.3
170

-20
208

-15
276

-10
357
b

Power consumption
Comp.\C
FR8.5F

-35
96

watt

-30
120

-25
145

-23.3
154

-20
172

-15
201

8219

-10
231

a2
d

Current consumption
Comp.\C
FR8.5F

-35
0.89

-30
0.96

A
-25
1.04

-23.3
1.07

-20
1.14

-15
1.25

-10
1.37

c
11

10

COP (EN 12900/CECOMAF)


Comp.\C
FR8.5F

-35
0.68

W/W

-30
0.75

-25
0.85

-23.3
0.90

-20
0.98

-15
1.11

-10
1.25

-30
0.92

-25
1.05

-23.3
1.10

-20
1.21

-15
1.37

-10
1.54

COP (ASHRAE)
Comp.\C
FR8.5F

-35
0.83

12

13
14

W/W

Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Static cooling, 220V 50Hz,
PTC consumption incl.

EN 12900/CECOMAF
55C
32C
55C

Main winding

ASHRAE
55C
32C
32C

Winding protector Start winding

LST
g

b
8217

a1

Accessories
Devices

Fig.

FR8.5F

a1

103N0011
103N0018

Starting relay

a2

117U6001
103N2010

PTC starting device

6.3 mm spades
4.8 mm spades

Main winding a1 Start winding


N

Cover

Starting capacitor 80 F

117U5015

Cord relief

103N1010

Protection screen for PTC

103N0476

Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities

August 2001

118-1917
118-1918
118-1919

Winding protector

CG.43.G2.02

CK.40.B6.02

June 2001

57

FR10F
Standard Compressor
R134a
220-240V 50Hz
Data Sheet (Replaces CG.43.D1.02)
General
FR10F

Code number

103G6950

103G

FR10F
Application

R134a

Blue stripe
Approvals

Application
Application
Evaporating temperature range
Voltage range

C
V/Hz

LBP

Barcode on
white background

-35 to -10

Yellow background

6950

8274-3

Compressor

DANFOSS COMPRESSORS

198 - 254 /50

Motor type

RSIR/CSIR

Max. ambient temperature


Comp. cooling at ambient temp.

38

32C

38C

S
O
F1
F2

= Static cooling normally sufficient


= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

Design
Displacement

cm3

Oil quantity

cm3

350

900

cm3

1450

kg

10.6

Maximum refrigerant charge


Free gas vol. in compressor
Weight without electrical equipment

9.05

204
178

16

19

Motor
215

8.1/8.2

Cut-in current LST/HST

12.8/8.2

Resistance, main and start winding (25C)

8.9/12.0

Dimensions

127
165
170
186
200

8.2 0.09

Process connector

location/I.D. mm

6.2 0.09

Discharge connector

location/I.D. mm

6.2 0.09

pcs.

A B
102
130

30

191

location/I.D. mm

127

B
Suction connector

C
E

196

25

30

mm

Compressors on a pallet

9.7

EN 60335-2-34 with Annex AA

80

122.5

June 2001

58

CG.43.D2.02

CK.40.B6.02

8253

24

40

40

55

156

243

32
55

Approvals

Height

35
127
150

watt

LRA (rated after 4 sec. UL984) LST/HST

101.6
70
60.5

Motor size

124.5
127.5

August 2001

Capacity (EN 12900/CECOMAF)


Comp.\C
FR10F

-35
82

-30
103

-25
138

watt
-23.3
153

-20
186

-15
248

-10
324

HST
c

Capacity (ASHRAE)
Comp.\C
FR10F

-35
101

watt

-30
127

-25
170

-23.3
188

-20
229

-15
306

-10
399
b

Power consumption
Comp.\C
FR10F

-35
116

watt

-30
137

-25
162

-23.3
171

-20
191

-15
223

8219

-10
259

a2
d

Current consumption
Comp.\C
FR10F

-35
1.04

-30
1.11

A
-25
1.18

-23.3
1.21

-20
1.26

-15
1.36

-10
1.48

c
11

10

COP (EN 12900/CECOMAF)


Comp.\C
FR10F

-35
0.71

W/W

-30
0.76

-25
0.85

-23.3
0.89

-20
0.98

-15
1.11

-30
0.93

-25
1.05

-23.3
1.10

-20
1.20

-15
1.37

-10
1.25

COP (ASHRAE)
Comp.\C
FR10F

-35
0.87

12

13
14

W/W

Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Static cooling, 220V 50Hz,
PTC consumption incl.

EN 12900/CECOMAF
55C
32C
55C

-10
1.54

Main winding

ASHRAE
55C
32C
32C

Winding protector Start winding

LST
g

b
8217

a1

Accessories
Devices

Fig.

FR10F

a1

103N0011
103N0018

Starting relay

a2

117U6002
103N2010

PTC starting device

6.3 mm spades
4.8 mm spades

Main winding a1 Start winding


N

Cover

Starting capacitor 80 F

117U5015

Cord relief

103N1010

Protection screen for PTC

103N0476

Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities

August 2001

118-1917
118-1918
118-1919

Winding protector

CG.43.D2.02

CK.40.B6.02

June 2001

59

SC15F
Standard Compressor
R134a
220-240V 50Hz
Data Sheet (Replaces CD.44.H3.02)
General
SC15F

Code number

104G8500

Code number compressor with oil cooler

104G8510

104G

SC15F
Application

R134a

Blue stripe
Approvals

8510

Barcode on
white background

Application
LBP*)

Application
Evaporating temperature range
Voltage range

198 - 254 /50

Motor type

RSIR/CSIR
C

Comp. cooling at ambient temp.

DANFOSS COMPRESSORS

Yellow background

-35 to -10

V/Hz

Max. ambient temperature

8275-2

Compressor

S
O
F1

38

32C

O/F1

38C

O/F1

F2

= Static cooling normally sufficient


= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

*) Can be used as a HBP compressor with 240V 50Hz mains (216-254V).

Design
Displacement

cm3

Oil quantity

cm3 600 (550 on comp. with oil cooler)

Maximum refrigerant charge


Free gas vol. in compressor
Weight without electrical equipment

15.28

1300

cm

1410

kg

12.6

204
178
170

16

19
9.7

watt

LRA (rated after 4 sec. UL984) LST/HST

315

12.6/12.6

Cut-in current LST/HST

17.2/12.6

Resistance, main and start winding (25C)

70
150

Motor size

127
101.6
35

Motor

6.7/11.8

Approvals

EN 60335-2-34, CCIB

127
165
186
218

Dimensions

E
209

183

B2

100

Suction connector

location/I.D. mm

8.2 0.09

Process connector

location/I.D. mm

6.2 0.09

Discharge connector

location/I.D. mm

6.2 0.09

Oil cooler

location/I.D. mm

6.2 0.09

pcs.

80

30

60

CD.44.H4.02

CK.40.B6.02

B2

37

37

107

May 2001

15

255

55

Compressors on a pallet

B A

B1

53

203

B1

63

107
115

55
63

mm

151

Height

8264

August 2001

Capacity (EN 12900/CECOMAF)


Comp.\C
SC15F

-35
100

-30
155

-25
230

watt
-23.3
260

-20
325

-15
439

-10
573

HST
c

Capacity (ASHRAE)
Comp.\C
SC15F

-35
123

-30
191

watt
-25
283

-23.3
320

-20
400

-15
541

-10
707
b
8222

Power consumption
Comp.\C
SC15F

-35
186

-30
229

watt
-25
275

-23.3
291

-20
324

-15
377

-10
432

a2
d

Current consumption
Comp.\C
SC15F

-35
1.67

-30
1.78

A
-25
1.93

-23.3
1.99

-20
2.11

-15
2.28

-10
2.44

c
11

10

COP (EN 12900/CECOMAF)


Comp.\C
SC15F

-35
0.54

W/W

-30
0.68

-25
0.84

-23.3
0.89

-20
1.00

-15
1.17

-10
1.33

-30
0.83

-25
1.03

-23.3
1.10

-20
1.23

-15
1.44

-10
1.64

COP (ASHRAE)
Comp.\C
SC15F

-35
0.66

12

13
14

W/W

Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Fan cooling, 220V 50Hz

EN 12900/CECOMAF
55C
32C
55C

Start winding
Main winding
Winding protector

ASHRAE
55C
32C
32C

LST

b
8221

a1
d

Accessories

Main winding

Devices
PTC starting device

Fig.
6.3 mm spades

SC15F

a1

103N0002

Starting relay

a2

117U6003

Cover

103N2009

Starting capacitor 80 F

117U5017

Cord relief

103N1004

Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities

August 2001

a1

Start winding

118-1917
118-1918
118-1919

Winding protector

CD.44.H4.02

CK.40.B6.02

May 2001

61

SC18F
Standard Compressor
R134a
220-240V 50Hz
Data Sheet (Replaces CD.44.B5.02)
General
SC18F

Code number

104G8800

Code number compressor with oil cooler

104G8810

104G

SC18F
Application

R134a

Blue stripe
Approvals

8810

Barcode on
white background

Application
LBP*)

Application
Evaporating temperature range
Voltage range

198 - 254 /50

Motor type

CSIR
C

Comp. cooling at ambient temp.

DANFOSS COMPRESSORS

Yellow background

-35 to -5

V/Hz

Max. ambient temperature

8275-3

Compressor

S
O
F1

38

32C

O/F1

38C

O/F1

F2

= Static cooling normally sufficient


= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

*) Can be used as a HBP compressor with 240V 50Hz mains (216-254V).

Design
Displacement

cm3

Oil quantity

cm3 600 (550 on comp. with oil cooler)

Maximum refrigerant charge


Free gas vol. in compressor
Weight without electrical equipment

17.69

1300

cm

1410

kg

13.1

204
178
170

16

19
9.7

LRA (rated after 4 sec. UL984) HST

watt

385

14.8

Cut-in current HST

14.8

Resistance, main and start winding (25C)

5.0/13.7

Approvals

EN 60335-2-34

70
150

Motor size

127
101.6
35

Motor

127
165
186
218

Dimensions

E
209

183

B2

100
10.2 0.09

Suction connector

location/I.D. mm

Process connector

location/I.D. mm

6.2 0.09

Discharge connector

location/I.D. mm

6.2 0.09

Oil cooler

location/I.D. mm

6.2 0.09

pcs.

80

30

62

CD.44.B6.02

CK.40.B6.02

B2

37

37

107

May 2001

15

255

55

Compressors on a pallet

B A

B1

53

203

B1

63

107
115

55
63

mm

151

Height

8264

August 2001

Capacity (EN 12900/CECOMAF)


Comp.\C
SC18F

-35
129

-30
194

-25
280

watt
-23.3
314

-20
388

-15
518

-10
669

-5
842
c

Capacity (ASHRAE)
Comp.\C
SC18F

-35
159

-30
238

watt
-25
345

-23.3
387

-20
478

-15
638

-10
825

-5
1039
b
8222

Power consumption
Comp.\C
SC18F

-35
206

-30
258

watt
-25
313

-23.3
332

-20
370

-15
430

-10
492

-5
556

a2
d

Current consumption
Comp.\C
SC18F

-35
2.04

-30
2.15

A
-25
2.29

-23.3
2.35

-20
2.46

-15
2.65

-10
2.84

-5
3.05

c
11

10

COP (EN 12900/CECOMAF)


Comp.\C
SC18F

-35
0.63

W/W

-30
0.75

-25
0.90

-23.3
0.95

-20
1.05

-15
1.20

-10
1.36

-30
0.92

-25
1.10

-23.3
1.17

-20
1.29

-15
1.48

-10
1.68

COP (ASHRAE)
Comp.\C
SC18F

-35
0.77

-5
1.51

12

13
14

W/W

Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Fan cooling, 220V 50Hz

EN 12900/CECOMAF
55C
32C
55C

-5
1.87

Start winding
Main winding
Winding protector

ASHRAE
55C
32C
32C

Accessories
Devices

Fig.

SC18F

Starting relay

a2

117U6005

Cover

103N2009

Starting capacitor 80 F

117U5017

Cord relief

103N1004

Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities

August 2001

118-1917
118-1918
118-1919

CD.44.B6.02

CK.40.B6.02

May 2001

63

SC21F
Standard Compressor
R134a
220-240V 50Hz
Data Sheet (Replaces CD.44.X1.02)
General
SC21F

Code number

104G8100

Code number compressor with oil cooler

104G8110

104G

SC21F
Application

R134a

Blue stripe
Approvals

8110

Barcode on
white background

Application
LBP*)

Application
Evaporating temperature range
Voltage range

198 - 254 /50

Motor type

CSIR
C

Comp. cooling at ambient temp.

DANFOSS COMPRESSORS

Yellow background

-35 to -5

V/Hz

Max. ambient temperature

8275

Compressor

S
O
F1

38

32C

O/F1

38C

O/F1

F2

= Static cooling normally sufficient


= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

*) Can be used as a HBP compressor with 240V 50Hz mains (216-254V).

Design
Displacement

cm3

Oil quantity

cm3 600 (550 on comp. with oil cooler)

Maximum refrigerant charge


Free gas vol. in compressor
Weight without electrical equipment

20.95

1300

cm

1460

kg

13.3

204
178
170

16

19
9.7

LRA (rated after 4 sec. UL984) HST

watt

495

18.6

Cut-in current HST

18.6

Resistance, main and start winding (25C)

3.7/14.1

Approvals

EN 60335-2-34

70
150

Motor size

127
101.6
35

Motor

127
165
186
218

Dimensions

E
219

193

B2

110
10.2 0.09

Suction connector

location/I.D. mm

Process connector

location/I.D. mm

6.2 0.09

Discharge connector

location/I.D. mm

6.2 0.09

Oil cooler

location/I.D. mm

6.2 0.09

pcs.

80

30

64

CD.44.X2.02

CK.40.B6.02

B2

37

37

107

May 2001

15

255

55

Compressors on a pallet

B A

B1

53

213

B1

63

107
115

55
63

mm

151

Height

8264

August 2001

Capacity (EN 12900/CECOMAF)


Comp.\C
SC21F

-35
185

-30
245

-25
335

watt
-23.3
375

-20
455

-15
610

-10
780

-5
990
c

Capacity (ASHRAE)
Comp.\C
SC21F

-35
228

-30
302

watt
-25
412

-23.3
462

-20
560

-15
750

-10
960

-5
1220
b
8222

Power consumption
Comp.\C
SC21F

-35
275

-30
325

watt
-25
380

-23.3
405

-20
450

-15
520

-10
600

-5
685

a2
d

Current consumption
Comp.\C
SC21F

-35
2.50

-30
2.64

A
-25
2.77

-23.3
2.81

-20
2.92

-15
3.16

-10
3.53

-5
4.09

c
11

10

COP (EN 12900/CECOMAF)


Comp.\C
SC21F

-35
0.67

W/W

-30
0.75

-25
0.88

-23.3
0.92

-20
1.01

-15
1.17

-10
1.30

-30
0.93

-25
1.08

-23.3
1.14

-20
1.24

-15
1.44

-10
1.60

COP (ASHRAE)
Comp.\C
SC21F

-35
0.83

-5
1.45

12

13
14

W/W

Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Fan cooling, 220V 50Hz

EN 12900/CECOMAF
55C
32C
55C

-5
1.78

Start winding
Main winding
Winding protector

ASHRAE
55C
32C
32C

Accessories
Devices

Fig.

SC21F

Starting relay

a2

117U6019

Cover

103N2009

Starting capacitor 80 F

117U5017

Cord relief

103N1004

Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities

August 2001

118-1917
118-1918
118-1919

CD.44.X2.02

CK.40.B6.02

May 2001

65

PLE35F
Energy-optimized Compressor
R134a
220-240V 50Hz
Data Sheet (Replaces CD.41.D5.02)
General
PLE35F

Code number

101G0201

PLE35F
R134a

Blue stripe

Application

101G

Application

0201

Approvals

Application
Evaporating temperature range
Voltage range

C
V/Hz

MBP

Barcode on
white background

-25 to 0

Yellow background

DANFOSS COMPRESSORS

8276

Compressor

198 - 254 /50

Motor type

RSCR*

Max. ambient temperature


Comp. cooling at ambient temp.

38

32C

38C

S
* run capacitor 4 F compulsory

S
O
F1
F2

= Static cooling normally sufficient


= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

Design
Displacement

cm3

Oil quantity

cm3

150

300

cm3

870

kg

4.8

Maximum refrigerant charge


Free gas vol. in compressor
Weight without electrical equipment

2.00

Motor
Motor size

watt

37

LRA (rated after 4 sec. UL984) LST

1.3

Cut-in current LST

5.0

Resistance, main and start winding (25C)

204
170

57.0/22.0
100

EN 60335-2-34 with Annex AA


35
70

Approvals

Dimensions
Height

Suction connector

mm

location/I.D. mm

137

135

B1

128

B2

73

6.2 0.09

Process connector

location/I.D. mm

6.2 0.09

Discharge connector

location/I.D. mm

5.0 +0.12/+0.20

pcs.

B1 B A
B2
206

150

8241

46
59
130

50
60.5

Compressors on a pallet

16

127

July 2001

66

CD.41.D6.02

CK.40.B6.02

August 2001

Capacity (EN 12900/CECOMAF)


Comp.\C
PLE35F

-25
32

-23.3
36

-20
45

watt
-15
60

-10
79

-5
100

0
125

Capacity (ASHRAE)
Comp.\C
PLE35F

-25
39

watt

-23.3
44

-20
55

-15
74

-10
97

-5
124

0
154
b
8216

Power consumption
Comp.\C
PLE35F

-25
44

watt

-23.3
46

-20
50

-15
56

-10
62

-5
69

a1

0
78
d

Current consumption
Comp.\C
PLE35F

-25
0.20

-23.3
0.21

-20
0.23

-15
0.26

-10
0.29

-5
0.32

0
0.34

COP (EN 12900/CECOMAF)


Comp.\C
PLE35F

-25
0.73

-25
0.89

Main winding

a1

Start winding

W/W

-23.3
0.78

-20
0.89

-15
1.07

-10
1.27

-5
1.45

-23.3
0.96

-20
1.09

-15
1.32

-10
1.57

-5
1.79

COP (ASHRAE)
Comp.\C
PLE35F

0
1.60

W/W

Test conditions
EN 12900/CECOMAF
Condensing temperature
55C
Ambient and suction gas temp.
32C
Liquid temperature
55C
Static cooling, with RC 4 F, 220V 50Hz,
PTC consumption incl.

0
1.98

Winding protector

ASHRAE
55C
32C
32C

Accessories
Devices
PTC starting device

6.3 mm spades
4.8 mm spades

Fig.

PLE35F

a1

103N0016
103N0021

Cover

103N0491

Cord relief

103N1010

Run capacitor 4 F (compulsory)


6.3 mm spades
4.8 mm spades

117-7117
117-7119

Protection screen for PTC

103N0476

Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities

August 2001

118-1917
118-1918
118-1919

CD.41.D6.02

CK.40.B6.02

July 2001

67

PLE50F
Energy-optimized Compressor
R134a
220-240V 50Hz
Data Sheet (Replaces CD.41.H1.02)
General
PLE50F

Code number

101G0221

PLE50F
R134a

Blue stripe

Application

101G

Application

0221

Approvals

Application
Evaporating temperature range
Voltage range

C
V/Hz

MBP

Barcode on
white background

-25 to 0

Yellow background

DANFOSS COMPRESSORS

8276-2

Compressor

198 - 254 /50

Motor type

RSCR*

Max. ambient temperature


Comp. cooling at ambient temp.

38

32C

38C

S
* run capacitor 4 F compulsory

S
O
F1
F2

= Static cooling normally sufficient


= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

Design
Displacement

cm3

Oil quantity

cm3

150

300

cm3

870

kg

4.8

Maximum refrigerant charge


Free gas vol. in compressor
Weight without electrical equipment

2.50

Motor
Motor size

watt

44

LRA (rated after 4 sec. UL984) LST

1.4

Cut-in current LST

5.1

Resistance, main and start winding (25C)

47.0/24.0
100

EN 60335-2-34 with Annex AA


35
70

Approvals

204
170

Dimensions
Height

Suction connector

mm

location/I.D. mm

140

138

B1

131

B2

73

6.2 0.09

Process connector

location/I.D. mm

6.2 0.09

Discharge connector

location/I.D. mm

5.0 +0.12/+0.20

pcs.

B1 B A
B2
206

150

8241

46
59
130

50
60.5

Compressors on a pallet

16

127

April 2001

68

CD.41.H2.02

CK.40.B6.02

August 2001

Capacity (EN 12900/CECOMAF)


Comp.\C
PLE50F

-25
42.0

-23.3
47.2

-20
57.9

watt
-15
76.2

-10
97.4

-5
122

0
150

Capacity (ASHRAE)
Comp.\C
PLE50F

-25
51.9

watt

-23.3
58.2

-20
71.5

-15
94.1

-10
120

-5
151

0
186
b
8216

Power consumption
Comp.\C
PLE50F

-25
52.0

watt

-23.3
54.4

-20
59.0

-15
66.3

-10
74.2

-5
82.8

a1

0
92.6
d

Current consumption
Comp.\C
PLE50F

-25
0.29

-23.3
0.30

-20
0.31

-15
0.34

-10
0.37

-5
0.40

COP (EN 12900/CECOMAF)


Comp.\C
PLE50F

-25
0.81

-25
1.00

0
0.44

Main winding

a1

Start winding

W/W

-23.3
0.87

-20
0.98

-15
1.15

-10
1.31

-5
1.47

-23.3
1.07

-20
1.21

-15
1.42

-10
1.62

-5
1.82

COP (ASHRAE)
Comp.\C
PLE50F

0
1.62

W/W

Test conditions
EN 12900/CECOMAF
Condensing temperature
55C
Ambient and suction gas temp.
32C
Liquid temperature
55C
Static cooling, with RC 4 F, 220V 50Hz,
PTC consumption incl.

0
2.01

Winding protector

ASHRAE
55C
32C
32C

Accessories
Devices
PTC starting device

6.3 mm spades
4.8 mm spades

Fig.

PLE50F

a1

103N0016
103N0021

Cover

103N0491

Cord relief

103N1010

Run capacitor 4 F (compulsory)


6.3 mm spades
4.8 mm spades

117-7117
117-7119

Protection screen for PTC

103N0476

Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities

August 2001

118-1917
118-1918
118-1919

CD.41.H2.02

CK.40.B6.02

April 2001

69

TLES3F
Energy-optimized Compressor
R134a
220-240V 50Hz
Data Sheet (Replaces CD.42.H6.02)
General
TLES3F

Code number

102G4310

Application

R134a
SUCTION
CONNECTOR

Blue stripe

Application

102G

TLES3F

4310

Approvals

Application

MBP

Evaporating temperature range


Voltage range

-25 to 0

V/Hz

Barcode on
white background

8277

Compressor

DANFOSS COMPRESSORS

Yellow background

198 - 254 /50

Motor type

RSIR/RSCR

Max. ambient temperature

43

32C

38C

43C

Displacement

cm3

3.13

Oil quantity

cm3

180

400

cm3

1790

kg

7.5

Comp. cooling at ambient temp.

S
O
F1
F2

= Static cooling normally sufficient


= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

Design

Maximum refrigerant charge


Free gas vol. in compressor
Weight without electrical equipment

16

Motor size

watt

74

LRA (rated after 4 sec. UL984) LST

2.6

Cut-in current LST

6.9

Resistance, main and start winding (25C)


Approvals

170
178
186
204

EN 60335-2-34 with Annex AA

location/I.D. mm

6.2 0.09

Process connector

location/I.D. mm

6.2 0.09

Discharge connector

location/I.D. mm

5.0 +0.12/+0.20

pcs.

A B

105
107

169

30

173

31.5
28

222
176

105

mm

Suction connector

Compressors on a pallet

27.5/15.1

Dimensions
Height

35
70
100

Motor

125

102

August 2001

70

CD.42.H7.02

CK.40.B6.02

71

29

51 20

45

157
60.5
66

8244

96
117

August 2001

Capacity (EN 12900/CECOMAF)


Comp.\C
TLES3F

-25
50.0

-23.3
56.2

-20
69.6

watt
-15
93.1

-10
121

-5
155

0
193
g

Capacity (ASHRAE)
Comp.\C
TLES3F

-25
61.7

-23.3
69.4

watt
-20
85.9

-15
115

-10
150

-5
191

-20
71.1

-15
81.1

-10
92.4

-5
105

0
120

-20
0.48

-15
0.52

-10
0.56

-5
0.60

0
0.65

Power consumption
Comp.\C
TLES3F

-25
62.0

-23.3
65.0

0
240

-25
0.45

-23.3
0.46

-25
0.81

-25
1.00

d
Main winding a1 Start winding
N

W/W

-23.3
0.87

-20
0.98

-15
1.15

-10
1.31

-5
1.47

-23.3
1.07

-20
1.21

-15
1.42

-10
1.62

-5
1.82

COP (ASHRAE)
Comp.\C
TLES3F

a1

COP (EN 12900/CECOMAF)


Comp.\C
TLES3F

8217

watt

Current consumption
Comp.\C
TLES3F

0
1.61

W/W

Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Static cooling, 220V 50Hz,
PTC consumption incl.

EN 12900/CECOMAF
55C
32C
55C

0
2.00

Winding protector

(pos.1)

ASHRAE
55C
32C
32C

Accessories

8223

Devices
PTC starting device
PTC starting device

Fig.

TLES3F

6.3 mm spades a1
4.8 mm spades (pos.1)

103N0011
103N0018

6.3 mm spades a1
4.8 mm spades (pos.2)

103N0016
103N0021

Cover

103N2010

Cord relief

103N1010

117-7117
117-7119

Run capacitor 4 F (optional)


6.3 mm spades
4.8 mm spades
Protection screen for PTC
Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities

August 2001

a1
d
e
Main winding

a1
Start winding

103N0476
118-1917
118-1918
118-1919

Winding protector

(pos.2)

CD.42.H7.02

CK.40.B6.02

August 2001

71

TLES4F
Energy-optimized Compressor
R134a
220-240V 50Hz
Data Sheet (Replaces CG.42.D2.02)
General
TLES4F

Code number

102G4410

Application

R134a
SUCTION
CONNECTOR

Blue stripe

Application

102G

TLES4F

4410

Approvals

Application

LBP

Evaporating temperature range


Voltage range

-35 to -10

V/Hz

Barcode on
white background

8277-3

Compressor

DANFOSS COMPRESSORS

Yellow background

198 - 254 /50

Motor type

RSIR/RSCR

Max. ambient temperature

43

32C

38C

43C

Displacement

cm3

3.86

Oil quantity

cm3

180

400

cm3

1790

kg

7.5

Comp. cooling at ambient temp.

S
O
F1
F2

= Static cooling normally sufficient


= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

Design

Maximum refrigerant charge


Free gas vol. in compressor
Weight without electrical equipment

16

Motor size
LRA (rated after 4 sec. UL984) LST

watt

80

2.9

Cut-in current LST

7.6

Resistance, main and start winding (25C)

25.7/15.7

Approvals

170
178
186
204

location/I.D. mm

6.2 0.09

Process connector

location/I.D. mm

6.2 0.09

Discharge connector

location/I.D. mm

5.0 +0.12/+0.20

pcs.

A B

105
107

169

30

173

31.5
28

222
176

105

mm

Suction connector

Compressors on a pallet

EN 60335-2-34 with Annex AA

Dimensions
Height

35
70
100

Motor

125

102

August 2001

72

CG.42.D3.02

CK.40.B6.02

71

29

51 20

45

157
60.5
66

8244

96
117

August 2001

Capacity (EN 12900/CECOMAF)


Comp.\C
TLES4F

-35
32.6

-30
49.5

-25
70.0

watt
-23.3
77.9

-20
94.8

-15
124

-10
160
g

Capacity (ASHRAE)
Comp.\C
TLES4F

-35
40.1

-30
61.1

watt
-25
86.4

-23.3
96.2

-20
117

-15
154

-10
197

-25
80.0

-23.3
83.8

-20
91.4

-15
104

-10
118

-25
0.54

-23.3
0.56

-20
0.60

-15
0.66

-10
0.73

Power consumption
Comp.\C
TLES4F

-35
59.9

-30
69.5

-35
0.45

-30
0.49

-35
0.54

-35
0.67

d
Main winding a1 Start winding
N

W/W

-30
0.71

-25
0.88

-23.3
0.93

-20
1.04

-15
1.20

-30
0.88

-25
1.08

-23.3
1.15

-20
1.28

-15
1.48

COP (ASHRAE)
Comp.\C
TLES4F

a1

COP (EN 12900/CECOMAF)


Comp.\C
TLES4F

8217

watt

Current consumption
Comp.\C
TLES4F

-10
1.35

W/W

Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Static cooling, 220V 50Hz,
PTC consumption incl.

EN 12900/CECOMAF
55C
32C
55C

-10
1.67

Winding protector

(pos.1)

ASHRAE
55C
32C
32C

Accessories

8223

Devices
PTC starting device
PTC starting device

Fig.

TLES4F

6.3 mm spades a1
4.8 mm spades (pos.1)

103N0011
103N0018

6.3 mm spades a1
4.8 mm spades (pos.2)

103N0016
103N0021

Cover

103N2010

Cord relief

103N1010

117-7117
117-7119

Run capacitor 4 F (optional)


6.3 mm spades
4.8 mm spades
Protection screen for PTC
Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities

August 2001

a1
d
e
Main winding

a1
Start winding

103N0476
118-1917
118-1918
118-1919

Winding protector

(pos.2)

CG.42.D3.02

CK.40.B6.02

August 2001

73

TLES5F
Energy-optimized Compressor
R134a
220-240V 50Hz
Data Sheet (Replaces CG.42.E2.02)
General
TLES5F

Code number

102G4510

Application

R134a
SUCTION
CONNECTOR

Blue stripe

Application

102G

TLES5F

4510

Approvals

Application

LBP

Evaporating temperature range


Voltage range

-35 to -10

V/Hz

Barcode on
white background

8277-4

Compressor

DANFOSS COMPRESSORS

Yellow background

198 - 254 /50

Motor type

RSIR/RSCR

Max. ambient temperature

Comp. cooling at ambient temp.

43*

32C

38C

43C

S
O
F1
F2

= Static cooling normally sufficient


= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

* run capacitor 4 F recommended in 43C ambient temperature

Design
Displacement

cm3

Oil quantity

cm3

180

400

cm3

1790

kg

7.6

Maximum refrigerant charge


Free gas vol. in compressor
Weight without electrical equipment

5.08

16

Motor size

watt

105

LRA (rated after 4 sec. UL984) LST

4.0

Cut-in current LST

8.5

Resistance, main and start winding (25C)

18.9/15.3

Approvals

170
178
186
204

location/I.D. mm

6.2 0.09

Process connector

location/I.D. mm

6.2 0.09

Discharge connector

location/I.D. mm

5.0 +0.12/+0.20

pcs.

A B

105
107

169

30

173

31.5
28

222
176

105

mm

Suction connector

Compressors on a pallet

EN 60335-2-34 with Annex AA

Dimensions
Height

35
70
100

Motor

125

102

August 2001

74

CG.42.E3.02

CK.40.B6.02

71

29

51 20

45

157
60.5
66

8244

96
117

August 2001

Capacity (EN 12900/CECOMAF)


Comp.\C
TLES5F

-35
49.9

-30
71.5

-25
98.0

watt
-23.3
108

-20
130

-15
169

-10
216
g

Capacity (ASHRAE)
Comp.\C
TLES5F

-35
61.5

-30
88.1

watt
-25
121

-23.3
134

-20
161

-15
209

-10
267

-25
105

-23.3
110

-20
121

-15
139

-10
158

-25
0.71

-23.3
0.73

-20
0.78

-15
0.85

-10
0.92

Power consumption
Comp.\C
TLES5F

-35
77.3

-30
90.5

-35
0.59

-30
0.65

-35
0.65

-35
0.80

d
Main winding a1 Start winding
N

W/W

-30
0.79

-25
0.93

-23.3
0.98

-20
1.08

-15
1.22

-10
1.37

-30
0.97

-25
1.15

-23.3
1.21

-20
1.33

-15
1.51

-10
1.69

COP (ASHRAE)
Comp.\C
TLES5F

a1

COP (EN 12900/CECOMAF)


Comp.\C
TLES5F

8217

watt

Current consumption
Comp.\C
TLES5F

W/W

Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Static cooling, 220V 50Hz,
PTC consumption incl.

EN 12900/CECOMAF
55C
32C
55C

Winding protector

(pos.1)

ASHRAE
55C
32C
32C

Accessories

8223

Devices

Fig.

TLES5F

PTC starting device

6.3 mm spades a1
4.8 mm spades (pos.1)

103N0011
103N0018

PTC starting device

6.3 mm spades a1
4.8 mm spades (pos.2)

103N0016
103N0021

Cover

103N2010

Cord relief

103N1010

117-7117
117-7119

Run capacitor 4 F (optional)


6.3 mm spades
4.8 mm spades
Protection screen for PTC
Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities

a1
d
e
Main winding

a1
Start winding

103N0476
118-1917
118-1918
118-1919

Winding protector

(pos.2)

* run capacitor 4 F recommended in 43C ambient temperature

August 2001

CG.42.E3.02

CK.40.B6.02

August 2001

75

TLES6F
Energy-optimized Compressor
R134a
220-240V 50Hz
Data Sheet (Replaces CD.42.T4.02)
General
TLES6F

Code number

102G4610

Application

R134a
SUCTION
CONNECTOR

Blue stripe

Application

102G

TLES6F

4610

Approvals

Application

LBP

Evaporating temperature range


Voltage range

-35 to -10

V/Hz

Barcode on
white background

8277-5

Compressor

DANFOSS COMPRESSORS

Yellow background

198 - 254 /50

Motor type

RSIR/RSCR

Max. ambient temperature

Comp. cooling at ambient temp.

43*

32C

38C

43C

S
O
F1
F2

= Static cooling normally sufficient


= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

* run capacitor 4 F compulsory in 38C and higher ambient temperature

Design
Displacement

cm3

Oil quantity

cm3

180

400

cm3

1790

kg

7.6

Maximum refrigerant charge


Free gas vol. in compressor
Weight without electrical equipment

5.70

16

Motor size

watt

120

LRA (rated after 4 sec. UL984) LST

4.5

Cut-in current LST

8.8

Resistance, main and start winding (25C)

16.5/16.9

Approvals

170
178
186
204

location/I.D. mm

6.2 0.09

Process connector

location/I.D. mm

6.2 0.09

Discharge connector

location/I.D. mm

5.0 +0.12/+0.20

pcs.

A B

105
107

169

30

173

31.5
28

222
176

105

mm

Suction connector

Compressors on a pallet

EN 60335-2-34 with Annex AA

Dimensions
Height

35
70
100

Motor

125

102

August 2001

76

CD.42.T5.02

CK.40.B6.02

71

29

51 20

45

157
60.5
66

8244

96
117

August 2001

Capacity (EN 12900/CECOMAF)


Comp.\C
TLES6F

-35
58

-30
77

-25
104

watt
-23.3
115

-20
139

-15
183

-10
235
g

Capacity (ASHRAE)
Comp.\C
TLES6F

-35
71

-30
95

watt
-25
128

-23.3
142

-20
172

-15
226

-10
290

-25
112

-23.3
118

-20
131

-15
151

-10
172

-25
0.75

-23.3
0.77

-20
0.82

-15
0.89

-10
0.97

Power consumption
Comp.\C
TLES6F

-35
76

-30
93

-35
0.63

-30
0.69

-35
0.76

-35
0.94

d
Main winding a1 Start winding
N

W/W

-30
0.82

-25
0.93

-23.3
0.97

-20
1.06

-15
1.21

-10
1.37

-30
1.01

-25
1.14

-23.3
1.20

-20
1.31

-15
1.49

-10
1.69

COP (ASHRAE)
Comp.\C
TLES6F

a1

COP (EN 12900/CECOMAF)


Comp.\C
TLES6F

8217

watt

Current consumption
Comp.\C
TLES6F

W/W

Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Static cooling, 220V 50Hz,
PTC consumption incl.

EN 12900/CECOMAF
55C
32C
55C

Winding protector

(pos.1)

ASHRAE
55C
32C
32C

Accessories

b
8223

Devices

Fig.

TLES6F

PTC starting device

6.3 mm spades a1
4.8 mm spades (pos.1)

103N0011
103N0018

PTC starting device

6.3 mm spades a1
4.8 mm spades (pos.2)

103N0016*
103N0021*

Cover

103N2010

Cord relief

103N1010

117-7117*
117-7119*

Run capacitor 4 F
6.3 mm spades
4.8 mm spades
Protection screen for PTC
Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities

a1
d
e
Main winding

a1
Start winding

103N0476
118-1917
118-1918
118-1919

Winding protector

(pos.2)

* run capacitor 4 F compulsory in 38C and higher ambient temp.

August 2001

CD.42.T5.02

CK.40.B6.02

August 2001

77

TLES7F
Energy-optimized Compressor
R134a
220-240V 50Hz
Data Sheet (Replaces CG.42.F1.02)
General
TLES7F

Code number

102G4710

Application

R134a
SUCTION
CONNECTOR

Blue stripe

Application

102G

TLES7F

4710

Approvals

Application

LBP

Evaporating temperature range


Voltage range

-35 to -10

V/Hz

Barcode on
white background

8277-6

Compressor

DANFOSS COMPRESSORS

Yellow background

198 - 254 /50

Motor type

RSIR/CSIR

Max. ambient temperature

Comp. cooling at ambient temp.

38*

32C

38C

S
O
F1

* run capacitor 4 F compulsory in 38C ambient temperature

F2

= Static cooling normally sufficient


= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

Design
Displacement

cm3

Oil quantity

cm3

180

400

cm3

1790

kg

7.8

Maximum refrigerant charge


Free gas vol. in compressor
Weight without electrical equipment

6.49

16

Motor size

watt

140

LRA (rated after 4 sec. UL984) LST

5.2

Cut-in current LST

9.9

Resistance, main and start winding (25C)

13.9/15.3

Dimensions
Height

mm

173

169

location/I.D. mm

6.2 0.09

Process connector

location/I.D. mm

6.2 0.09

Discharge connector

location/I.D. mm

5.0 +0.12/+0.20

170
178
186
204

222
176

31.5
28

Suction connector

EN 60335-2-34 with Annex AA

30

Approvals

35
70
100

Motor

Compressors on a pallet

pcs.

105

105
107

A B

125

102

June 2001

78

CG.42.F2.02

CK.40.B6.02

71

29

51 20

45

157
60.5
66

8244

96
117

August 2001

Capacity (EN 12900/CECOMAF)


Comp.\C
TLES7F

-35
66

-30
89

-25
120

watt
-23.3
133

-20
160

-15
208

-10
264
g

Capacity (ASHRAE)
Comp.\C
TLES7F

-35
81

-30
109

watt
-25
148

-23.3
163

-20
197

-15
256

-10
326

-25
127

-23.3
134

-20
148

-15
170

-10
192

-25
0.89

-23.3
0.91

-20
0.96

-15
1.03

-10
1.12

Power consumption
Comp.\C
TLES7F

-35
89

-30
107

-35
0.79

-30
0.84

-35
0.74

-35
0.91

d
Main winding a1 Start winding
N

W/W

-30
0.83

-25
0.94

-23.3
0.99

-20
1.08

-15
1.22

-10
1.37

-30
1.02

-25
1.16

-23.3
1.22

-20
1.33

-15
1.51

-10
1.69

COP (ASHRAE)
Comp.\C
TLES7F

a1

COP (EN 12900/CECOMAF)


Comp.\C
TLES7F

8217

watt

Current consumption
Comp.\C
TLES7F

W/W

Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Static cooling, 220V 50Hz,
PTC consumption incl.

EN 12900/CECOMAF
55C
32C
55C

Winding protector

(pos.1)

ASHRAE
55C
32C
32C

Accessories

b
8223

Devices

Fig.

TLES7F

PTC starting device

6.3 mm spades a1
4.8 mm spades (pos.1)

103N0011
103N0018

PTC starting device

6.3 mm spades a1
4.8 mm spades (pos.2)

103N0016*
103N0021*

Cover

103N2010

Cord relief

103N1010

117-7117*
117-7119*

Run capacitor 4 F
6.3 mm spades
4.8 mm spades
Protection screen for PTC
Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities

a1
d
e
Main winding

a1
Start winding

103N0476
118-1917
118-1918
118-1919

Winding protector

(pos.2)

* run capacitor 4 F compulsory in 38C ambient temperature

August 2001

CG.42.F2.02

CK.40.B6.02

June 2001

79

NLE6F
Energy-optimized Compressor
R134a
220-240V 50Hz
Data Sheet (Replaces CD.43.K4.02)
General
NLE6F

Code number

105G6607

105G

NLE6F
Application

R134a

Blue stripe
Approvals

Application
Application
Evaporating temperature range
Voltage range

C
V/Hz

LBP

Barcode on
white background

-35 to -10

Yellow background

6607

DANFOSS COMPRESSORS

8279

Compressor

198 - 254 /50

Motor type

RSIR/RSCR

Max. ambient temperature


Comp. cooling at ambient temp.

38

32C

38C

S
O
F1
F2

= Static cooling normally sufficient


= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

Design
Displacement

cm3

Oil quantity

cm3

290

400

cm3

2310

kg

10.2

Maximum refrigerant charge


Free gas vol. in compressor
Weight without electrical equipment

6.13

204
170

Motor
watt

140

LRA (rated after 4 sec. UL984) LST

5.0

Cut-in current LST

9.4

Resistance, main and start winding (25C)

Approvals

100
70

Motor size

14.9/17.9

16

EN 60335-2-34 with Annex AA

178

205

Dimensions

6.2 0.09

Process connector

location/I.D. mm

6.2 0.09

Discharge connector

location/I.D. mm

5.0 +0.12/+0.20

Compressors on a pallet

pcs.

A B

102.5

191

80

75.5

25

197

15

location/I.D. mm

35

Suction connector

C
mm

93.5

Height

254

113

July 2001

80

CD.43.K5.02

CK.40.B6.02

27

47

54
78

51

72

166

60.5

8248

119
127

August 2001

Capacity (EN 12900/CECOMAF)


Comp.\C
NLE6F

-35
57

-30
80

-25
112

watt
-23.3
124

-20
151

-15
198

-10
252
g

Capacity (ASHRAE)
Comp.\C
NLE6F

-35
70

watt

-30
99

-25
138

-23.3
153

-20
186

-15
244

-10
311

-25
108

-23.3
115

-20
129

-15
153

-10
179

-25
0.70

-23.3
0.73

-20
0.77

-15
0.86

-10
0.95

Power consumption
Comp.\C
NLE6F

-35
71

-35
0.59

-30
0.64

-35
0.80

-35
0.99

d
Main winding a1 Start winding
N

W/W

-30
0.91

-25
1.04

-23.3
1.08

-20
1.17

-15
1.29

-30
1.12

-25
1.27

-23.3
1.33

-20
1.44

-15
1.60

COP (ASHRAE)
Comp.\C
NLE6F

a1

COP (EN 12900/CECOMAF)


Comp.\C
NLE6F

8217

watt

-30
89

Current consumption
Comp.\C
NLE6F

-10
1.41

W/W

Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Static cooling, 220V 50Hz,
PTC consumption incl.

EN 12900/CECOMAF
55C
32C
55C

-10
1.74

Winding protector

(pos.1)

ASHRAE
55C
32C
32C

b
8223

Accessories
Devices

Fig.

NLE6F

a1

PTC starting device

6.3 mm spades a1
4.8 mm spades (pos.1)

103N0011
103N0018

PTC starting device

6.3 mm spades a1
4.8 mm spades (pos.2)

103N0016
103N0021

Cover

103N2010

Cord relief

103N1010

Run capacitor 4 F (optional)


6.3 mm spades
4.8 mm spades

117-7117
117-7119

Protection screen for PTC

Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities

August 2001

d
e
Main winding

a1
Start winding

103N0476
118-1917
118-1918
118-1919

Winding protector

(pos.2)

CD.43.K5.02

CK.40.B6.02

July 2001

81

NLE7F
Energy-optimized Compressor
R134a
220-240V 50Hz
Data Sheet (Replaces CG.43.N1.02)
General
NLE7F

105G

NLE7F

Code number

105G6702

Code number

105G6705

Application

R134a

Blue stripe
Approvals

6702

Barcode on
white background

Application
Application

LBP

Evaporating temperature range


Voltage range

-35 to -10

V/Hz

198 - 254 /50

Motor type

RSIR/RSCR

Max. ambient temperature

38

32C

38C

Displacement

cm3

7.27

Oil quantity

cm3

290

400

cm3

2310

kg

10.1

Comp. cooling at ambient temp.

DANFOSS COMPRESSORS

Yellow background

8279-2

Compressor

S
O
F1
F2

= Static cooling normally sufficient


= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

Design

Maximum refrigerant charge


Free gas vol. in compressor
Weight without electrical equipment

204
170

Motor
watt

140

LRA (rated after 4 sec. UL984) LST

5.0

Cut-in current LST

9.4

Resistance, main and start winding (25C)

14.9/17.9

Approvals

100
70

Motor size

16

EN 60335-2-34 with Annex AA

178

205

E
C

105G6705
191

A B

Suction connector

location/I.D. mm

C 6.2 0.09

Process connector

location/I.D. mm

D 6.2 0.09

6.5 0.09

Discharge connector

location/I.D. mm

E 5.0 +0.12/+0.20

5.0 +0.12/+0.20

Compressors on a pallet

pcs.

6.5 0.09

102.5

75.5

197

15

25

105G6702
mm

35

Height

93.5

Dimensions

254

80

113

August 2001

82

CG.43.N2.02

CK.40.B6.02

27

47

54
78

51

72

166

60.5

8248

119
127

August 2001

Capacity (EN 12900/CECOMAF)


Comp.\C
NLE7F

-35
68

-30
97

-25
135

watt
-23.3
150

-20
182

-15
238

-10
302
g

Capacity (ASHRAE)
Comp.\C
NLE7F

-35
84

watt

-30
119

-25
166

-23.3
185

-20
224

-15
293

-10
373

-25
131

-23.3
139

-20
156

-15
181

-10
207

-25
0.80

-23.3
0.83

-20
0.88

-15
0.98

-10
1.09

Power consumption
Comp.\C
NLE7F

-35
84

-35
0.66

-30
0.72

-35
0.81

-35
1.00

d
Main winding a1 Start winding
N

W/W

-30
0.90

-25
1.03

-23.3
1.08

-20
1.17

-15
1.32

-30
1.11

-25
1.27

-23.3
1.33

-20
1.44

-15
1.62

COP (ASHRAE)
Comp.\C
NLE7F

a1

COP (EN 12900/CECOMAF)


Comp.\C
NLE7F

8217

watt

-30
107

Current consumption
Comp.\C
NLE7F

-10
1.46

W/W

Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Static cooling, 220V 50Hz,
PTC consumption incl.

EN 12900/CECOMAF
55C
32C
55C

-10
1.80

Winding protector

(pos.1)

ASHRAE
55C
32C
32C

b
8223

Accessories
Devices

Fig.

NLE7F

a1

PTC starting device

6.3 mm spades a1
4.8 mm spades (pos.1)

103N0011
103N0018

PTC starting device

6.3 mm spades a1
4.8 mm spades (pos.2)

103N0016
103N0021

Cover

103N2010

Cord relief

103N1010

Run capacitor 4 F (optional)


6.3 mm spades
4.8 mm spades

117-7117
117-7119

Protection screen for PTC

Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities

August 2001

d
e
Main winding

a1
Start winding

103N0476
118-1917
118-1918
118-1919

Winding protector

(pos.2)

CG.43.N2.02

CK.40.B6.02

August 2001

83

NLE8FK
Energy-optimized Compressor
R134a
220-240V 50Hz
Data Sheet (Replaces CG.43.S1.02)
General
NLE8FK

Code number

105G6827

105G

NLE8FK
Application

R134a

Blue stripe
Approvals

Application
Application
Evaporating temperature range
Voltage range

C
V/Hz

LBP

Barcode on
white background

-35 to -10

Yellow background

6827

DANFOSS COMPRESSORS

8279-4

Compressor

198 - 254 /50

Motor type

RSIR/RSCR

Max. ambient temperature


Comp. cooling at ambient temp.

38

32C

38C

S
O
F1
F2

= Static cooling normally sufficient


= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

Design
Displacement

cm3

Oil quantity

cm3

320

400

cm3

2230

kg

9.8

Maximum refrigerant charge


Free gas vol. in compressor
Weight without electrical equipment

8.05

204
170

Motor size

watt

165

LRA (rated after 4 sec. UL984) LST

5.8

Cut-in current LST

9.8

Resistance, main and start winding (25C)

12.9/18.0

Approvals

100
70

Motor

16

EN 60335-2-34 with Annex AA

178

205

Dimensions

6.2 0.09

Process connector

location/I.D. mm

6.2 0.09

Discharge connector

location/I.D. mm

5.0 +0.12/+0.20

Compressors on a pallet

pcs.

A B

102.5

191

80

75.5

B
location/I.D. mm

25

197

15

35

Suction connector

C
mm

93.5

Height

254

113

July 2001

84

CG.43.S2.02

CK.40.B6.02

27

47

54
78

51

72

166

60.5

8248

119
127

August 2001

Capacity (EN 12900/CECOMAF)


Comp.\C
NLE8FK

-35
82

-30
112

-25
149

watt
-23.3
163

-20
194

-15
249

-10
317
g

Capacity (ASHRAE)
Comp.\C
NLE8FK

-35
101

watt

-30
139

-25
184

-23.3
201

-20
240

-15
308

-10
392

-25
145

-23.3
152

-20
167

-15
191

-10
218

-25
1.00

-23.3
1.02

-20
1.08

-15
1.17

-10
1.28

Power consumption
Comp.\C
NLE8FK

-35
109

-35
0.88

-30
0.93

-35
0.75

-35
0.92

d
Main winding a1 Start winding
N

W/W

-30
0.89

-25
1.03

-23.3
1.07

-20
1.16

-15
1.30

-10
1.45

-30
1.10

-25
1.27

-23.3
1.32

-20
1.43

-15
1.61

-10
1.80

COP (ASHRAE)
Comp.\C
NLE8FK

a1

COP (EN 12900/CECOMAF)


Comp.\C
NLE8FK

8217

watt

-30
126

Current consumption
Comp.\C
NLE8FK

W/W

Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Static cooling, 220V 50Hz,
PTC consumption incl.

EN 12900/CECOMAF
55C
32C
55C

Winding protector

(pos.1)

ASHRAE
55C
32C
32C

b
8223

Accessories
Devices

Fig.

NLE8FK

a1

PTC starting device

6.3 mm spades a1
4.8 mm spades (pos.1)

103N0011
103N0018

PTC starting device

6.3 mm spades a1
4.8 mm spades (pos.2)

103N0016
103N0021

Cover

103N2010

Cord relief

103N1010

Run capacitor 4 F (optional)


6.3 mm spades
4.8 mm spades

117-7117
117-7119

Protection screen for PTC

Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities

August 2001

d
e
Main winding

a1
Start winding

103N0476
118-1917
118-1918
118-1919

Winding protector

(pos.2)

CG.43.S2.02

CK.40.B6.02

July 2001

85

NLE9F
Energy-optimized Compressor
R134a
220-240V 50Hz
Data Sheet (Replaces CG.43.O1.02)
General
NLE9F

105G

NLE9F

Code number

105G6803

Code number

105G6805*)
*) Performance data established on 8.2 mm
suction line. Restrictions due to 6.2 mm
suction line can affect system performance.

Application

Application

R134a

Blue stripe
Approvals

6803

Barcode on
white background

DANFOSS COMPRESSORS

Yellow background

Application

8279-3

Compressor

LBP

Evaporating temperature range


Voltage range

-35 to -10

V/Hz

198 - 254 /50

Motor type

S
O
F1

RSIR/RSCR

Max. ambient temperature

38

32C

38C

Displacement

cm3

8.35

Oil quantity

cm3

290

400

cm3

2310

kg

10.1

watt

165

Comp. cooling at ambient temp.

F2

= Static cooling normally sufficient


= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

Design

Maximum refrigerant charge


Free gas vol. in compressor
Weight without electrical equipment

204
170

Motor size

100
70

Motor
LRA (rated after 4 sec. UL984) LST

6.4

Cut-in current LST

10.7

Resistance, main and start winding (25C)

12.9/18.0

Approvals

16

EN 60335-2-34 with Annex AA

178

205

E
C

A B

location/I.D. mm

C 8.2 0.09

Process connector

location/I.D. mm

D 6.2 0.09

6.2 0.09

Discharge connector

location/I.D. mm

E 6.2 0.09

5.0 +0.12/+0.20

pcs.

254

80

8248

51

72

166

Compressors on a pallet

6.2 0.09

102.5

Suction connector

113

August 2001

86

CG.43.O2.02

CK.40.B6.02

75.5

191

27

47

54
78

15

197

25

105G6805

93.5

105G6803
mm

35

Height

60.5

Dimensions

119
127

August 2001

Capacity (EN 12900/CECOMAF)


Comp.\C
NLE9F

-35
82

-30
112

-25
154

watt
-23.3
171

-20
207

-15
271

-10
346
g

Capacity (ASHRAE)
Comp.\C
NLE9F

-35
101

watt

-30
138

-25
190

-23.3
210

-20
255

-15
334

-10
427

-25
150

-23.3
159

-20
177

-15
206

-10
237

-25
1.09

-23.3
1.15

-20
1.27

-15
1.48

-10
1.73

Power consumption
Comp.\C
NLE9F

-35
102

-35
0.85

-30
0.95

-35
0.80

-35
0.99

d
Main winding a1 Start winding
N

W/W

-30
0.90

-25
1.03

-23.3
1.08

-20
1.17

-15
1.31

-10
1.46

-30
1.11

-25
1.27

-23.3
1.32

-20
1.44

-15
1.62

-10
1.80

COP (ASHRAE)
Comp.\C
NLE9F

a1

COP (EN 12900/CECOMAF)


Comp.\C
NLE9F

8217

watt

-30
125

Current consumption
Comp.\C
NLE9F

W/W

Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Static cooling, 220V 50Hz,
PTC consumption incl.

EN 12900/CECOMAF
55C
32C
55C

Winding protector

(pos.1)

ASHRAE
55C
32C
32C

b
8223

Accessories
Devices

Fig.

NLE9F

a1

PTC starting device

6.3 mm spades a1
4.8 mm spades (pos.1)

103N0011
103N0018

PTC starting device

6.3 mm spades a1
4.8 mm spades (pos.2)

103N0016
103N0021

Cover

103N2010

Cord relief

103N1010

Run capacitor 4 F (optional)


6.3 mm spades
4.8 mm spades

117-7117
117-7119

Protection screen for PTC

Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities

August 2001

d
e
Main winding

a1
Start winding

103N0476
118-1917
118-1918
118-1919

Winding protector

(pos.2)

CG.43.O2.02

CK.40.B6.02

August 2001

87

TLY4F
High Energy-optimized Compressor
R134a
220-240V 50Hz
Data Sheet (Replaces CD.42M6.02)
General
TLY4F

Code number

102G4441

Application

R134a
SUCTION
CONNECTOR

Blue stripe

Application

102G

TLY4F

4441

Approvals

Application

LBP

Evaporating temperature range


Voltage range

-35 to -10

V/Hz

Barcode on
white background

8278

Compressor

DANFOSS COMPRESSORS

Yellow background

198 - 254 /50

Motor type

RSCR/RSIR

Max. ambient temperature

43

32C

38C

43C

Displacement

cm3

3.86

Oil quantity

cm3

180

400

cm3

1790

kg

7.6

Comp. cooling at ambient temp.

S
O
F1
F2

= Static cooling normally sufficient


= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

Design

Maximum refrigerant charge


Free gas vol. in compressor
Weight without electrical equipment

16

Motor size
LRA (rated after 4 sec. UL984) LST

watt

80

2.9

Cut-in current LST

7.6

Resistance, main and start winding (25C)

25.7/15.7

Approvals

170
178
186
204

location/I.D. mm

6.2 0.09

Process connector

location/I.D. mm

6.2 0.09

Discharge connector

location/I.D. mm

5.0 +0.12/+0.20

pcs.

A B

105
107

169

30

173

31.5
28

222
176

105

mm

Suction connector

Compressors on a pallet

EN 60335-2-34 with Annex AA

Dimensions
Height

35
70
100

Motor

125

102

August 2001

88

CD.42.M7.02

CK.40.B6.02

71

29

51 20

45

157
60.5
66

8244

96
117

August 2001

Capacity (EN 12900/CECOMAF)


Comp.\C
TLY4F

-35
34.6

-30
51.5

-25
72.0

watt
-23.3
79.9

-20
96.8

-15
126

-10
162
g

Capacity (ASHRAE)
Comp.\C
TLY4F

-35
42.6

watt

-30
63.5

-25
88.9

-23.3
98.6

-20
119

-15
156

-10
200

-25
73.0

-23.3
76.5

-20
83.6

-15
95.2

-10
108

-25
0.36

-23.3
0.37

-20
0.41

-15
0.46

-10
0.52

Power consumption
Comp.\C
TLY4F

-35
54.4

-35
0.27

-30
0.31

-35
0.63

-35
0.78

d
Main winding a1 Start winding
N

W/W

-30
0.81

-25
0.99

-23.3
1.04

-20
1.16

-15
1.33

-30
1.00

-25
1.22

-23.3
1.29

-20
1.43

-15
1.64

COP (ASHRAE)
Comp.\C
TLY4F

a1

COP (EN 12900/CECOMAF)


Comp.\C
TLY4F

8217

watt

-30
63.4

Current consumption
Comp.\C
TLY4F

-10
1.49

W/W

Test conditions
EN 12900/CECOMAF
Condensing temperature
55C
Ambient and suction gas temp.
32C
Liquid temperature
55C
Static cooling, with RC 4 F, 220V 50Hz,
PTC consumption incl.

-10
1.85

Winding protector

(pos.1)

ASHRAE
55C
32C
32C

b
8223

Accessories
Devices
PTC starting device
PTC starting device

Fig.
6.3 mm spades a1
4.8 mm spades (pos.1)
6.3 mm spades a1
4.8 mm spades (pos.2)

TLY4F

a1

103N0011
103N0018
103N0016
103N0021

Cover

103N2010

Cord relief

103N1010

Run capacitor 4 F (optional)


6.3 mm spades
4.8 mm spades

117-7117
117-7119

Protection screen for PTC

Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities

August 2001

d
e
Main winding

a1
Start winding

103N0476
118-1917
118-1918
118-1919

(pos.2)

CD.42.M7.02

CK.40.B6.02

Winding protector

August 2001

89

TLY5FK
High Energy-optimized Compressor
R134a
220-240V 50Hz
Data Sheet (Replaces CG.42.I2.02)
General
TLY5FK

Code number

102G4547

Application

R134a
SUCTION
CONNECTOR

Blue stripe

Application

102G

TLY5FK

4547

Approvals

Application

LBP

Evaporating temperature range


Voltage range

-35 to -10

V/Hz

Barcode on
white background

8278-2

Compressor

DANFOSS COMPRESSORS

Yellow background

198 - 254 /50

Motor type

RSCR/RSIR

Max. ambient temperature

Comp. cooling at ambient temp.

43*

32C

38C

43C

S
O
F1
F2

= Static cooling normally sufficient


= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

* run capacitor 4 F compulsory in 43C ambient temperature

Design
Displacement

cm3

Oil quantity

cm3

180

400

cm3

1790

kg

7.6

Maximum refrigerant charge


Free gas vol. in compressor
Weight without electrical equipment

5.08

16

Motor size

watt

105

LRA (rated after 4 sec. UL984) LST

4.0

Cut-in current LST

8.5

Resistance, main and start winding (25C)

18.9/15.3

Approvals

170
178
186
204

location/I.D. mm

6.2 0.09

Process connector

location/I.D. mm

6.2 0.09

Discharge connector

location/I.D. mm

5.0 +0.12/+0.20

pcs.

A B

105
107

169

30

173

31.5
28

222
176

105

mm

Suction connector

Compressors on a pallet

EN 60335-2-34 with Annex AA

Dimensions
Height

35
70
100

Motor

125

102

August 2001

90

CG.42.I3.02

CK.40.B6.02

71

29

51 20

45

157
60.5
66

8244

96
117

August 2001

Capacity (EN 12900/CECOMAF)


Comp.\C
TLY5FK

-35
49.9

-30
71.5

-25
98.0

watt
-23.3
108

-20
130

-15
169

-10
216
g

Capacity (ASHRAE)
Comp.\C
TLY5FK

-35
61.5

watt

-30
88.1

-25
121

-23.3
134

-20
161

-15
209

-10
267

-25
97.0

-23.3
102

-20
112

-15
128

-10
146

-25
0.55

-23.3
0.57

-20
0.62

-15
0.68

-10
0.76

Power consumption
Comp.\C
TLY5FK

-35
71.4

-35
0.43

-30
0.49

-35
0.70

-35
0.86

d
Main winding a1 Start winding
N

W/W

-30
0.85

-25
1.01

-23.3
1.06

-20
1.17

-15
1.32

-30
1.05

-25
1.25

-23.3
1.31

-20
1.44

-15
1.64

COP (ASHRAE)
Comp.\C
TLY5FK

a1

COP (EN 12900/CECOMAF)


Comp.\C
TLY5FK

8217

watt

-30
83.6

Current consumption
Comp.\C
TLY5FK

-10
1.48

W/W

Test conditions
EN 12900/CECOMAF
Condensing temperature
55C
Ambient and suction gas temp.
32C
Liquid temperature
55C
Static cooling, with RC 4 F, 220V 50Hz,
PTC consumption incl.

-10
1.83

Winding protector

(pos.1)

ASHRAE
55C
32C
32C

b
8223

Accessories
Devices

Fig.

TLY5FK

a1

PTC starting device

6.3 mm spades a1
4.8 mm spades (pos.1)

103N0011
103N0018

PTC starting device

6.3 mm spades a1
4.8 mm spades (pos.2)

103N0016*
103N0021*

Cover

103N2010

Cord relief

103N1010

117-7117*
117-7119*

Run capacitor 4 F
6.3 mm spades
4.8 mm spades
Protection screen for PTC
Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities

d
e
Main winding

a1
Start winding

103N0476
118-1917
118-1918
118-1919

(pos.2)

Winding protector

* run capacitor 4 F compulsory in 43C ambient temperature

August 2001

CG.42.I3.02

CK.40.B6.02

August 2001

91

TLX6FK
High Energy-optimized Compressor
R134a
220-240V 50Hz
Data Sheet (Replaces CG.42.U1.02)
General
TLX6FK

Code number

102G4656

Application

102G

TLX6FK
R134a
SUCTION
CONNECTOR

Blue stripe

Application

4656

Approvals

Application

LBP

Evaporating temperature range


Voltage range

-35 to -10

V/Hz

Barcode on
white background

RSCR*

Comp. cooling at ambient temp.

DANFOSS COMPRESSORS

Yellow background

198 - 254 /50

Motor type
Max. ambient temperature

8421

Compressor

38

32C

38C

S
O
F1

F2

= Static cooling normally sufficient


= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

* run capacitor 4 F compulsory

Design
Displacement

cm3

Oil quantity

cm3

180

400

cm3

1790

kg

8.2

Maximum refrigerant charge


Free gas vol. in compressor
Weight without electrical equipment

5.70

16

Motor size

watt

117

LRA (rated after 4 sec. UL984) LST

3.6

Cut-in current LST

8.4

Resistance, main and start winding (25C)

19.0/13.0

Approvals

35
70
100

Motor

EN 60335-2-34 with Annex AA

170
178
186
204

Dimensions
A

173

169

location/I.D. mm

6.2 0.09

Process connector

location/I.D. mm

6.2 0.09

Discharge connector

location/I.D. mm

5.0 +0.12/+0.20

222
176

31.5
28

Suction connector

mm

30

Height

Compressors on a pallet

pcs.

105

105
107

A B

125

102

April 2001

92

CG.42.U2.02

CK.40.B6.02

71

29

51 20

45

157
60.5
66

8244

96
117

August 2001

Capacity (EN 12900/CECOMAF)


Comp.\C
TLX6FK

-35
59.5

-30
84.9

-25
115

watt
-23.3
126

-20
151

-15
193

Capacity (ASHRAE)
Comp.\C
TLX6FK

-35
73.4

-10
243
g

watt

-30
105

-25
142

-23.3
156

-20
186

-15
238

-10
300
b
8223

Power consumption
Comp.\C
TLX6FK

-35
71.9

watt

-30
87.1

-25
103

-23.3
108

-20
119

-15
136

a1

-10
156
d

Current consumption
Comp.\C
TLX6FK

-35
0.35

-30
0.42

-23.3
0.51

-20
0.57

-15
0.65

COP (EN 12900/CECOMAF)


Comp.\C
TLX6FK

-35
0.83

-35
1.02

-10
0.75

Main winding

a1
Start winding

W/W

-30
0.97

-25
1.12

-23.3
1.17

-20
1.27

-15
1.41

-30
1.20

-25
1.38

-23.3
1.45

-20
1.57

-15
1.75

COP (ASHRAE)
Comp.\C
TLX6FK

A
-25
0.49

-10
1.56

W/W

Test conditions
EN 12900/CECOMAF
Condensing temperature
55C
Ambient and suction gas temp.
32C
Liquid temperature
55C
Static cooling, with RC 4 F, 220V 50Hz,
PTC consumption incl.

-10
1.93

Winding protector

ASHRAE
55C
32C
32C

Accessories
Devices
PTC starting device

6.3 mm spades
4.8 mm spades

Fig.

TLX6FK

a1

103N0016
103N0021

Cover

103N2010

Cord relief

103N1010

Run capacitor 4 F (compulsory)


6.3 mm spades
4.8 mm spades

117-7117
117-7119

Protection screen for PTC

103N0476

Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities

August 2001

118-1917
118-1918
118-1919

CG.42.U2.02

CK.40.B6.02

April 2001

93

NLY5.5FK
High Energy-optimized Compressor
R134a
220-240V 50Hz
Data Sheet (Replaces CG.43.R3.02)
General
NLY5.5FK

Code number

105G6631

Application

R134a
SUCTION
CONNECTOR

Blue stripe

Application

105G

NLY5.5FK

6631

Approvals

Application

LBP

Evaporating temperature range


Voltage range

-35 to -10

V/Hz

Barcode on
white background

DANFOSS COMPRESSORS

8280-4

Compressor

Yellow background

198 - 254 /50

Motor type

RSCR*

Max. ambient temperature


Comp. cooling at ambient temp.

43

32C

38C

43C

S
O
F1
F2

= Static cooling normally sufficient


= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

* run capacitor 4 F compulsory

Design
Displacement

cm3

Oil quantity

cm3

290

400

cm3

2310

kg

10.8

Maximum refrigerant charge


Free gas vol. in compressor
Weight without electrical equipment

6.13

204
170

Motor size

watt

135

LRA (rated after 4 sec. UL984) LST

4.3

Cut-in current LST

8.3

Resistance, main and start winding (25C)

16.0/15.1

Approvals

EN 60335-2-34 with Annex AA

100
70

Motor

16
178

205

E
C

Suction connector

location/I.D. mm

6.2 0.09

Process connector

location/I.D. mm

6.2 0.09

Discharge connector

location/I.D. mm

5.0 +0.12/+0.20

Compressors on a pallet

pcs.

A B

102.5

197

75.5

203

15

93.5

mm

35

Height

25

Dimensions

254

80

113

August 2001

94

CG.43.R4.02

CK.40.B6.02

27

47

54
78

51

72

166

60.5

8250

119
127

August 2001

Capacity (EN 12900/CECOMAF)


Comp.\C
NLY5.5FK

-35
57.8

-30
87.3

-25
123

watt
-23.3
137

-20
166

-15
218

-10
280
g

Capacity (ASHRAE)
Comp.\C
NLY5.5FK

-35
71.2

watt

-30
108

-25
152

-23.3
169

-20
205

-15
269

-10
346
b
8223

Power consumption
Comp.\C
NLY5.5FK

-35
72.9

watt

-30
87.7

-25
104

-23.3
110

-20
121

-15
140

a1

-10
160
d

Current consumption
Comp.\C
NLY5.5FK

-35
0.33

-30
0.41

-23.3
0.51

-20
0.56

-15
0.65

-10
0.73

COP (EN 12900/CECOMAF)


Comp.\C
NLY5.5FK

-35
0.79

-35
0.98

Main winding

a1
Start winding

W/W

-30
0.99

-25
1.18

-23.3
1.25

-20
1.37

-15
1.56

-10
1.75

-30
1.23

-25
1.46

-23.3
1.54

-20
1.69

-15
1.92

-10
2.16

COP (ASHRAE)
Comp.\C
NLY5.5FK

A
-25
0.48

W/W

Test conditions
EN 12900/CECOMAF
Condensing temperature
55C
Ambient and suction gas temp.
32C
Liquid temperature
55C
Static cooling, with RC 4 F, 220V 50Hz,
PTC consumption incl.

Winding protector

ASHRAE
55C
32C
32C

Accessories
Devices
PTC starting device

6.3 mm spades
4.8 mm spades

Fig.

NLY5.5FK

a1

103N0016
103N0021

Cover

103N2010

Cord relief

103N1010

Run capacitor 4 F (compulsory)


6.3 mm spades
4.8 mm spades

117-7117
117-7119

Protection screen for PTC

103N0476

Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities

August 2001

118-1917
118-1918
118-1919

CG.43.R4.02

CK.40.B6.02

August 2001

95

NLY6F
High Energy-optimized Compressor
R134a
220-240V 50Hz
Data Sheet (Replaces CD.43.H5.02)
General
NLY6F

Code number

105G6630

Application

R134a
SUCTION
CONNECTOR

Blue stripe

Application

105G

NLY6F

6630

Approvals

Application

LBP

Evaporating temperature range


Voltage range

-35 to -10

V/Hz

Barcode on
white background

DANFOSS COMPRESSORS

8280

Compressor

Yellow background

198 - 254 /50

Motor type

RSCR*

Max. ambient temperature


Comp. cooling at ambient temp.

43

32C

38C

43C

S
O
F1
F2

= Static cooling normally sufficient


= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

* run capacitor 4 F compulsory

Design
Displacement

cm3

Oil quantity

cm3

290

400

cm3

2310

kg

10.8

Maximum refrigerant charge


Free gas vol. in compressor
Weight without electrical equipment

6.70

204
170

Motor size

watt

135

LRA (rated after 4 sec. UL984) LST

4.3

Cut-in current LST

8.3

Resistance, main and start winding (25C)

16.0/15.1

Approvals

EN 60335-2-34 with Annex AA

100
70

Motor

16
178

205

E
C

Suction connector

location/I.D. mm

6.2 0.09

Process connector

location/I.D. mm

6.2 0.09

Discharge connector

location/I.D. mm

5.0 +0.12/+0.20

Compressors on a pallet

pcs.

A B

102.5

197

75.5

203

15

93.5

mm

35

Height

25

Dimensions

254

80

113

August 2001

96

CD.43.H6.02

CK.40.B6.02

27

47

54
78

51

72

166

60.5

8250

119
127

August 2001

Capacity (EN 12900/CECOMAF)


Comp.\C
NLY6F

-35
80

-30
104

-25
138

watt
-23.3
152

-20
182

-15
235

-10
299
g

Capacity (ASHRAE)
Comp.\C
NLY6F

-35
98

-30
128

watt
-25
170

-23.3
187

-20
224

-15
290

-10
369
b
8223

Power consumption
Comp.\C
NLY6F

-35
81

-30
99

watt
-25
118

-23.3
125

-20
138

-15
159

a1

-10
181
d

Current consumption
Comp.\C
NLY6F

-35
0.38

-30
0.47

-23.3
0.57

-20
0.63

-15
0.72

-10
0.81

COP (EN 12900/CECOMAF)


Comp.\C
NLY6F

-35
0.99

-35
1.21

Main winding

a1
Start winding

W/W

-30
1.05

-25
1.17

-23.3
1.22

-20
1.32

-15
1.48

-10
1.65

-30
1.30

-25
1.44

-23.3
1.50

-20
1.62

-15
1.82

-10
2.04

COP (ASHRAE)
Comp.\C
NLY6F

A
-25
0.54

W/W

Test conditions
EN 12900/CECOMAF
Condensing temperature
55C
Ambient and suction gas temp.
32C
Liquid temperature
55C
Static cooling, with RC 4 F, 220V 50Hz,
PTC consumption incl.

Winding protector

ASHRAE
55C
32C
32C

Accessories
Devices
PTC starting device 6.3 mm spades
4.8 mm spades

Fig.

NLY6F

a1

103N0016
103N0021

Cover

103N2010

Cord relief

103N1010

Run capacitor 4 F (compulsory)


6.3 mm spades
4.8 mm spades

117-7117
117-7119

Protection screen for PTC

103N0476

Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities

August 2001

118-1917
118-1918
118-1919

CD.43.H6.02

CK.40.B6.02

August 2001

97

NLY7F
High Energy-optimized Compressor
R134a
220-240V 50Hz
Data Sheet (Replaces CG.43.P2.02)
General
NLY7F

Code number

105G6730

Application

R134a
SUCTION
CONNECTOR

Blue stripe

Application

105G

NLY7F

6730

Approvals

Application

LBP

Evaporating temperature range


Voltage range

-35 to -10

V/Hz

Barcode on
white background

DANFOSS COMPRESSORS

8280-2

Compressor

Yellow background

198 - 254 /50

Motor type

RSCR*

Max. ambient temperature


Comp. cooling at ambient temp.

43

32C

38C

43C

S
O
F1
F2

= Static cooling normally sufficient


= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

* run capacitor 4 F compulsory

Design
Displacement

cm3

Oil quantity

cm3

290

400

cm3

2310

kg

10.8

watt

180

Maximum refrigerant charge


Free gas vol. in compressor
Weight without electrical equipment

7.27

204
170

Motor size
LRA (rated after 4 sec. UL984) LST

5.7

Cut-in current LST

10.3

Resistance, main and start winding (25C)

11.8/12.7

Approvals

EN 60335-2-34 with Annex AA

100
70

Motor

16
178

205

E
C

Suction connector

location/I.D. mm

6.2 0.09

Process connector

location/I.D. mm

6.2 0.09

Discharge connector

location/I.D. mm

5.0 +0.12/+0.20

Compressors on a pallet

pcs.

A B

102.5

197

75.5

203

15

93.5

mm

35

Height

25

Dimensions

254

80

113

August 2001

98

CG.43.P3.02

CK.40.B6.02

27

47

54
78

51

72

166

60.5

8250

119
127

August 2001

Capacity (EN 12900/CECOMAF)


Comp.\C
NLY7F

-35
94

-30
121

-25
158

watt
-23.3
173

-20
206

-15
265

-10
334
g

Capacity (ASHRAE)
Comp.\C
NLY7F

-35
116

-30
149

watt
-25
195

-23.3
213

-20
254

-15
326

-10
412
b
8223

Power consumption
Comp.\C
NLY7F

-35
103

-30
117

watt
-25
134

-23.3
140

-20
153

-15
175

a1

-10
200
d

Current consumption
Comp.\C
NLY7F

-35
0.47

-30
0.54

-23.3
0.65

-20
0.70

-15
0.80

COP (EN 12900/CECOMAF)


Comp.\C
NLY7F

-35
0.91

-35
1.12

-10
0.90

Main winding

a1
Start winding

W/W

-30
1.03

-25
1.18

-23.3
1.24

-20
1.35

-15
1.51

-30
1.27

-25
1.45

-23.3
1.52

-20
1.66

-15
1.86

COP (ASHRAE)
Comp.\C
NLY7F

A
-25
0.62

-10
1.67

W/W

Test conditions
EN 12900/CECOMAF
Condensing temperature
55C
Ambient and suction gas temp.
32C
Liquid temperature
55C
Static cooling, with RC 4 F, 220V 50Hz,
PTC consumption incl.

-10
2.06

Winding protector

ASHRAE
55C
32C
32C

Accessories
Devices
PTC starting device 6.3 mm spades
4.8 mm spades

Fig.

NLY7F

a1

103N0016
103N0021

Cover

103N2010

Cord relief

103N1010

Run capacitor 4 F (compulsory)


6.3 mm spades
4.8 mm spades

117-7117
117-7119

Protection screen for PTC

103N0476

Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities

August 2001

118-1917
118-1918
118-1919

CG.43.P3.02

CK.40.B6.02

August 2001

99

NLY9FK
High Energy-optimized Compressor
R134a
220-240V 50Hz
Data Sheet (Replaces CG.43.Q1.02)
General
NLY9FK

Code number

105G6830

Application

R134a
SUCTION
CONNECTOR

Blue stripe

Application

105G

NLY9FK

6830

Approvals

Application

LBP

Evaporating temperature range


Voltage range

-35 to -10

V/Hz

Barcode on
white background

DANFOSS COMPRESSORS

8280-3

Compressor

Yellow background

198 - 254 /50

Motor type

RSCR*

Max. ambient temperature


Comp. cooling at ambient temp.

43

32C

38C

43C

S
O
F1
F2

= Static cooling normally sufficient


= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

* run capacitor 4 F compulsory

Design
Displacement

cm3

Oil quantity

cm3

290

400

cm3

2310

kg

10.8

watt

190

Maximum refrigerant charge


Free gas vol. in compressor
Weight without electrical equipment

8.35

204
170

Motor size
LRA (rated after 4 sec. UL984) LST

6.1

Cut-in current LST

11.3

Resistance, main and start winding (25C)

11.0/9.0

Approvals

EN 60335-2-34 with Annex AA

100
70

Motor

16
178

205

E
C

Suction connector

location/I.D. mm

8.2 0.09

Process connector

location/I.D. mm

6.2 0.09

Discharge connector

location/I.D. mm

6.2 0.09

Compressors on a pallet

pcs.

A B

102.5

197

75.5

203

15

93.5

mm

35

Height

25

Dimensions

254

80

113

August 2001

100

CG.43.Q2.02

CK.40.B6.02

27

47

54
78

51

72

166

60.5

8250

119
127

August 2001

Capacity (EN 12900/CECOMAF)


Comp.\C
NLY9FK

-35
94

-30
130

-25
175

watt
-23.3
192

-20
230

-15
297

-10
380
g

Capacity (ASHRAE)
Comp.\C
NLY9FK

-35
116

-30
161

watt
-25
216

-23.3
237

-20
284

-15
367

-10
469
b
8223

Power consumption
Comp.\C
NLY9FK

-35
108

-30
129

watt
-25
151

-23.3
160

-20
176

-15
203

a1

-10
232
d

Current consumption
Comp.\C
NLY9FK

-35
0.58

-30
0.68

-23.3
0.82

-20
0.90

-15
1.03

COP (EN 12900/CECOMAF)


Comp.\C
NLY9FK

-35
0.87

-35
1.08

-10
1.16

Main winding

a1
Start winding

W/W

-30
1.01

-25
1.15

-23.3
1.20

-20
1.30

-15
1.46

-10
1.63

-30
1.25

-25
1.42

-23.3
1.49

-20
1.61

-15
1.81

-10
2.02

COP (ASHRAE)
Comp.\C
NLY9FK

A
-25
0.79

W/W

Test conditions
EN 12900/CECOMAF
Condensing temperature
55C
Ambient and suction gas temp.
32C
Liquid temperature
55C
Static cooling, with RC 4 F, 220V 50Hz,
PTC consumption incl.

Winding protector

ASHRAE
55C
32C
32C

Accessories
Devices
PTC starting device 6.3 mm spades
4.8 mm spades

Fig.

NLY9FK

a1

103N0016
103N0021

Cover

103N2010

Cord relief

103N1010

Run capacitor 4 F (compulsory)


6.3 mm spades
4.8 mm spades

117-7117
117-7119

Protection screen for PTC

103N0476

Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities

August 2001

118-1917
118-1918
118-1919

CG.43.Q2.02

CK.40.B6.02

August 2001

101

NLY5.5FK.2
High Energy-optimized Compressor
R134a
220-240V 50Hz
Data Sheet
General
NLY5.5FK.2

Code number

105G6634

Application

R134a
SUCTION
CONNECTOR

Blue stripe

Application

6634

Approvals

Application

LBP

Evaporating temperature range


Voltage range

-35 to -10

V/Hz

105G

NLY5.5FK.2

Barcode on
white background

DANFOSS COMPRESSORS

8426-2

Compressor

Yellow background

198 - 254 /50

Motor type

RSCR*

Max. ambient temperature


Comp. cooling at ambient temp.

43

32C

38C

43C

S
O
F1
F2

= Static cooling normally sufficient


= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

* run capacitor 4 F compulsory

Design
Displacement

cm3

Oil quantity

cm3

290

400

cm3

2310

kg

10.8

Maximum refrigerant charge


Free gas vol. in compressor
Weight without electrical equipment

6.13

204
170

Motor size

watt

135

LRA (rated after 4 sec. UL984) LST

4.3

Cut-in current LST

8.3

Resistance, main and start winding (25C)

16.0/15.1

Approvals

EN 60335-2-34 with Annex AA

100
70

Motor

16
178

205

E
C

Suction connector

location/I.D. mm

8.2 0.09

Process connector

location/I.D. mm

6.2 0.09

Discharge connector

location/I.D. mm

6.2 0.09

Compressors on a pallet

pcs.

A B

102.5

197

75.5

203

15

93.5

mm

35

Height

25

Dimensions

254

80

113

August 2001

102

CH.43.Q1.02

CK.40.B6.02

27

47

54
78

51

72

166

60.5

8250

119
127

August 2001

Capacity (EN 12900/CECOMAF)


Comp.\C
NLY5.5FK.2

-35

-30

-25
130

watt
-23.3
142

-20

-15

-10

Capacity (ASHRAE)
Comp.\C
NLY5.5FK.2

-35

watt

-30

-25
160

-23.3
175

-20

-15

-10
b
8223

Power consumption
Comp.\C
NLY5.5FK.2

-35

watt

-30

-25
106

-23.3
110

-20

-15

a1

-10
d

Current consumption
Comp.\C
NLY5.5FK.2

-35

-30

-23.3
0.51

-20

-15

-10

COP (EN 12900/CECOMAF)


Comp.\C
NLY5.5FK.2

-35

-35

Main winding

a1
Start winding

W/W

-30

-25
1.23

-23.3
1.29

-20

-15

-30

-25
1.52

-23.3
1.58

-20

-15

-10

COP (ASHRAE)
Comp.\C
NLY5.5FK.2

A
-25
0.48

W/W

Test conditions
EN 12900/CECOMAF
Condensing temperature
55C
Ambient and suction gas temp.
32C
Liquid temperature
55C
Static cooling, with RC 4 F, 220V 50Hz,
PTC consumption incl.,
preliminary data

-10
Winding protector

ASHRAE
55C
32C
32C

Accessories
Devices
PTC starting device

6.3 mm spades
4.8 mm spades

Fig.

NLY5.5FK.2

a1

103N0016
103N0021

Cover

103N2010

Cord relief

103N1010

Run capacitor 4 F (compulsory)


6.3 mm spades
4.8 mm spades

117-7117
117-7119

Protection screen for PTC

103N0476

Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities

August 2001

118-1917
118-1918
118-1919

CH.43.Q1.02

CK.40.B6.02

August 2001

103

NLY6FK.2
High Energy-optimized Compressor
R134a
220-240V 50Hz
Data Sheet
General
NLY6FK.2

Code number

105G6636

Application

R134a
SUCTION
CONNECTOR

Blue stripe

Application

105G

NLY6FK.2

6636

Approvals

Application

LBP

Evaporating temperature range


Voltage range

-35 to -10

V/Hz

Barcode on
white background

DANFOSS COMPRESSORS

8426-3

Compressor

Yellow background

198 - 254 /50

Motor type

RSCR*

Max. ambient temperature


Comp. cooling at ambient temp.

43

32C

38C

43C

S
O
F1
F2

= Static cooling normally sufficient


= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

* run capacitor 4 F compulsory

Design
Displacement

cm3

Oil quantity

cm3

290

400

cm3

2310

kg

10.8

Maximum refrigerant charge


Free gas vol. in compressor
Weight without electrical equipment

6.70

204
170

Motor size

watt

135

LRA (rated after 4 sec. UL984) LST

4.3

Cut-in current LST

8.3

Resistance, main and start winding (25C)

16.0/15.1

Approvals

EN 60335-2-34 with Annex AA

100
70

Motor

16
178

205

E
C

Suction connector

location/I.D. mm

8.2 0.09

Process connector

location/I.D. mm

6.2 0.09

Discharge connector

location/I.D. mm

6.2 0.09

Compressors on a pallet

pcs.

A B

102.5

197

75.5

203

15

93.5

mm

35

Height

25

Dimensions

254

80

113

August 2001

104

CH.43.R1.02

CK.40.B6.02

27

47

54
78

51

72

166

60.5

8250

119
127

August 2001

Capacity (EN 12900/CECOMAF)


Comp.\C
NLY6FK.2

-35

-30

-25
140

watt
-23.3
154

-20

-15

-10

Capacity (ASHRAE)
Comp.\C
NLY6FK.2

-35

-30

watt
-25
172

-23.3
190

-20

-15

-10
b
8223

Power consumption
Comp.\C
NLY6FK.2

-35

-30

watt
-25
115

-23.3
121

-20

-15

a1

-10
d

Current consumption
Comp.\C
NLY6FK.2

-35

-30

-23.3
0.57

-20

-15

-10

COP (EN 12900/CECOMAF)


Comp.\C
NLY6FK.2

-35

-35

Main winding

a1
Start winding

W/W

-30

-25
1.22

-23.3
1.27

-20

-15

-10

-30

-25
1.50

-23.3
1.56

-20

-15

-10

COP (ASHRAE)
Comp.\C
NLY6FK.2

A
-25
0.54

W/W

Test conditions
EN 12900/CECOMAF
Condensing temperature
55C
Ambient and suction gas temp.
32C
Liquid temperature
55C
Static cooling, with RC 4 F, 220V 50Hz,
PTC consumption incl.,
preliminary data

Winding protector
ASHRAE
55C
32C
32C

Accessories
Devices
PTC starting device 6.3 mm spades
4.8 mm spades

Fig.

NLY6FK.2

a1

103N0016
103N0021

Cover

103N2010

Cord relief

103N1010

Run capacitor 4 F (compulsory)


6.3 mm spades
4.8 mm spades

117-7117
117-7119

Protection screen for PTC

103N0476

Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities

August 2001

118-1917
118-1918
118-1919

CH.43.R1.02

CK.40.B6.02

August 2001

105

NLY7FK.2
High Energy-optimized Compressor
R134a
220-240V 50Hz
Data Sheet
General
NLY7FK.2

Code number

105G6734

Application

R134a
SUCTION
CONNECTOR

Blue stripe

Application

105G

NLY7FK.2

6734

Approvals

Application

LBP

Evaporating temperature range


Voltage range

-35 to -10

V/Hz

Barcode on
white background

DANFOSS COMPRESSORS

8426

Compressor

Yellow background

198 - 254 /50

Motor type

RSCR*

Max. ambient temperature


Comp. cooling at ambient temp.

43

32C

38C

43C

S
O
F1
F2

= Static cooling normally sufficient


= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

* run capacitor 4 F compulsory

Design
Displacement

cm3

Oil quantity

cm3

290

400

cm3

2310

kg

10.8

Maximum refrigerant charge


Free gas vol. in compressor
Weight without electrical equipment

7.27

204
170

Motor size

watt

150

LRA (rated after 4 sec. UL984) LST

4.9

Cut-in current LST

9.2

Resistance, main and start winding (25C)

14.3/12.9

Approvals

EN 60335-2-34 with Annex AA

100
70

Motor

16
178

205

E
C

Suction connector

location/I.D. mm

8.2 0.09

Process connector

location/I.D. mm

6.2 0.09

Discharge connector

location/I.D. mm

6.2 0.09

Compressors on a pallet

pcs.

A B

102.5

197

75.5

203

15

93.5

mm

35

Height

25

Dimensions

254

80

113

August 2001

106

CH.43.O1.02

CK.40.B6.02

27

47

54
78

51

72

166

60.5

8250

119
127

August 2001

Capacity (EN 12900/CECOMAF)


Comp.\C
NLY7FK.2

-35
81.8

-30
118

-25
160

watt
-23.3
176

-20
209

-15
266

Capacity (ASHRAE)
Comp.\C
NLY7FK.2

-35
101

-10
334
g

watt

-30
146

-25
197

-23.3
217

-20
258

-15
329

-10
413
b
8223

Power consumption
Comp.\C
NLY7FK.2

-35
92.1

watt

-30
109

-25
128

-23.3
135

-20
149

-15
172

a1

-10
195
d

Current consumption
Comp.\C
NLY7FK.2

-35
0.45

-30
0.53

-23.3
0.66

-20
0.72

-15
0.82

COP (EN 12900/CECOMAF)


Comp.\C
NLY7FK.2

-35
0.89

-35
1.09

-10
0.93

Main winding

a1
Start winding

W/W

-30
1.09

-25
1.25

-23.3
1.30

-20
1.40

-15
1.55

-10
1.71

-30
1.34

-25
1.54

-23.3
1.61

-20
1.73

-15
1.92

-10
2.12

COP (ASHRAE)
Comp.\C
NLY7FK.2

A
-25
0.62

W/W

Test conditions
EN 12900/CECOMAF
Condensing temperature
55C
Ambient and suction gas temp.
32C
Liquid temperature
55C
Static cooling, with RC 4 F, 220V 50Hz,
PTC consumption incl.

Winding protector

ASHRAE
55C
32C
32C

Accessories
Devices
PTC starting device

6.3 mm spades
4.8 mm spades

Fig.

NLY7FK.2

a1

103N0016
103N0021

Cover

103N2010

Cord relief

103N1010

Run capacitor 4 F (compulsory)


6.3 mm spades
4.8 mm spades

117-7117
117-7119

Protection screen for PTC

103N0476

Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities

August 2001

118-1917
118-1918
118-1919

CH.43.O1.02

CK.40.B6.02

August 2001

107

NLY9FK.2
High Energy-optimized Compressor
R134a
220-240V 50Hz
Data Sheet
General
NLY9FK.2

Code number

105G6834

Application

R134a
SUCTION
CONNECTOR

Blue stripe

Application

105G

NLY9FK.2

6834

Approvals

Application

LBP

Evaporating temperature range


Voltage range

-35 to -10

V/Hz

Barcode on
white background

DANFOSS COMPRESSORS

8426-4

Compressor

Yellow background

198 - 254 /50

Motor type

RSCR*

Max. ambient temperature


Comp. cooling at ambient temp.

43

32C

38C

43C

S
O
F1
F2

= Static cooling normally sufficient


= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

* run capacitor 4 F compulsory

Design
Displacement

cm3

Oil quantity

cm3

290

400

cm3

2310

kg

10.8

watt

190

Maximum refrigerant charge


Free gas vol. in compressor
Weight without electrical equipment

8.35

204
170

Motor size
LRA (rated after 4 sec. UL984) LST

6.1

Cut-in current LST

11.3

Resistance, main and start winding (25C)

11.0/9.0

Approvals

EN 60335-2-34 with Annex AA

100
70

Motor

16
178

205

E
C

Suction connector

location/I.D. mm

8.2 0.09

Process connector

location/I.D. mm

6.2 0.09

Discharge connector

location/I.D. mm

6.2 0.09

Compressors on a pallet

pcs.

A B

102.5

197

75.5

203

15

93.5

mm

35

Height

25

Dimensions

254

80

113

August 2001

108

CH.43.S1.02

CK.40.B6.02

27

47

54
78

51

72

166

60.5

8250

119
127

August 2001

Capacity (EN 12900/CECOMAF)


Comp.\C
NLY9FK.2

-35

-30

-25
180

watt
-23.3
198

-20

-15

-10

Capacity (ASHRAE)
Comp.\C
NLY9FK.2

-35

-30

watt
-25
222

-23.3
245

-20

-15

-10
b
8223

Power consumption
Comp.\C
NLY9FK.2

-35

-30

watt
-25
145

-23.3
153

-20

-15

a1

-10
d

Current consumption
Comp.\C
NLY9FK.2

-35

-30

-23.3
0.82

-20

-15

COP (EN 12900/CECOMAF)


Comp.\C
NLY9FK.2

-35

-35

-10

Main winding

a1
Start winding

W/W

-30

-25
1.24

-23.3
1.29

-20

-15

-10

-30

-25
1.53

-23.3
1.60

-20

-15

-10

COP (ASHRAE)
Comp.\C
NLY9FK.2

A
-25
0.77

W/W

Test conditions
EN 12900/CECOMAF
Condensing temperature
55C
Ambient and suction gas temp.
32C
Liquid temperature
55C
Static cooling, with RC 4 F, 220V 50Hz,
PTC consumption incl.,
preliminary data

Winding protector
ASHRAE
55C
32C
32C

Accessories
Devices
PTC starting device 6.3 mm spades
4.8 mm spades

Fig.

NLY9FK.2

a1

103N0016
103N0021

Cover

103N2010

Cord relief

103N1010

Run capacitor 4 F (compulsory)


6.3 mm spades
4.8 mm spades

117-7117
117-7119

Protection screen for PTC

103N0476

Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities

August 2001

118-1917
118-1918
118-1919

CH.43.S1.02

CK.40.B6.02

August 2001

109

TLV5F
Variable Speed Drive Compressor
R134a
220-240V 50-60Hz
Data Sheet (Replaces CG.42.K3.02)
General
TLV5F

Code number: Comp. without electronic unit

102G4585

Code number: Electronic unit

105N4001

Application

102G

TLV5F

Application

R134a
SUCTION
CONNECTOR

Blue stripe

4585

Approvals

LBP

Barcode on
white background

-35 to -10

Yellow background

Application
Evaporating temperature range
Voltage range

C
V/Hz

HST

Comp. cooling at ambient temp.

DANFOSS COMPRESSORS

198 - 254 /50 - 60

Starting characteristics
Max. ambient temperature

8396

Compressor

43

32C

38C

43C

S
O
F1

= Static cooling normally sufficient


= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

F2

Features
Speed range

rpm

2000 - 4000

Control modes with

- mech. thermostat 220V ON/OFF

integrated speed control AEO*)

- 5V DC ON/OFF

External speed control

- 5V DC 200-400Hz

Protections

- current
- speed

204
186
178
170

- temperature
*)AEO - Adaptive Energy Optimizer

Design

16

9
3

Displacement

cm

Oil quantity

cm3

180

400

Free gas vol. in compressor


Weight: Compressor/Electronic unit

cm3

1790

kg

7.9/0.6

35
70
100

Maximum refrigerant charge

5.08

permanent magnet

Resistance, all 3 windings (25C)

14.0

Approvals

electronic cut-off
A B

105
107

105

Cut-in current HST

31.5
28

LRA (rated after 4 sec. UL984) HST

30

Motor type

230
176

Motor

EN 60335-2-34 with Annex AA

Dimensions
Height

mm

173

169

6.2 0.09

6.2 0.09

location/I.D. mm

5.0 +0.12/+0.20

Compressors on a pallet (without el. unit) pcs.


July 2001

110

125
CG.42.K4.02

CK.40.B6.02

102

29
71

location/I.D. mm

Discharge connector

51 20

Process connector

66

location/I.D. mm

45

Suction connector

157
120

8394

96
117

August 2001

Capacity (EN 12900/CECOMAF)


rpm \ C
2,000
2,500
3,000
4,000

-35
38.3
46.8
53.3
62.6

-30
52.1
63.6
73.6
92.5

watt

-25
70.1
85.7
100
129

-23.3
77.3
95
110
142

-20
92.9
114
133
172

-15
121
149
174
224

-10
155
191
224
287

-25
86.5
106
123
159

-23.3
95
117
136
176

-20
115
141
164
212

-15
150
184
215
277

-10
192
236
276
354

-25
62.1
77.1
92.4
124

-23.3
65.7
81.5
98
131

-20
72.8
90.3
108
146

-15
84.1
104
125
169

-10
96
119
144
194

-25
1.21
1.23
1.24
1.22

-23.3
1.26
1.29
1.30
1.27

-20
1.37
1.40
1.41
1.38

-15
1.54
1.59
1.60
1.53

-10
1.72
1.78
1.80
1.68

Capacity (ASHRAE)
rpm \ C
2,000
2,500
3,000
4,000

-35
47.2
57.6
65.6
77.2

-30
64.2
78.4
90.8
114

watt

Power consumption
rpm \ C
2,000
2,500
3,000
4,000

-35
41.9
52.0
62.2
82.9

-30
51.8
64.4
77.2
103

-35
0.88
0.91
0.92
0.87

-30
1.04
1.06
1.07
1.05

6
10

7
8

-35
1.13
1.11
1.06
0.93

-30
1.01
0.99
0.95
0.89

-25
1.13
1.11
1.08
1.04

-23.3
1.18
1.16
1.13
1.09

-20
1.28
1.26
1.23
1.18

-15
1.44
1.43
1.39
1.33

-30
1.24
1.22
1.18
1.10

-25
1.39
1.37
1.33
1.28

-23.3
1.45
1.43
1.39
1.34

-20
1.57
1.56
1.52
1.46

-15
1.78
1.76
1.72
1.64

-10
1.62
1.60
1.56
1.48

R+
R-

3
4

f 5

EN 12900/CECOMAF
55C
32C
55C

Legend

-10
2.00
1.98
1.92
1.82

ASHRAE
55C
32C
32C

Accessories
Devices
Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities

August 2001

L
N
N
C
C
L
N

W/W

Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Static cooling, 220V 50Hz

13

W/W

COP (ASHRAE)
rpm \ C
2,000
2,500
3,000
4,000

13

8
7

11

-35
0.91
0.90
0.86
0.76

8385-2

14

COP (EN 12900/CECOMAF)


rpm \ C
2,000
2,500
3,000
4,000

watt

Current consumption
rpm \ C
2,000
2,500
3,000
4,000

12
13

TLV5F

Number

Description

1:
2:
3:
4:
5:
6:
7:
8:
9:
10:
11:
12:
13:
14:

Power supply
Fan connection
Thermostat connection
Light connection
Signal input
Mounting recesses
Cover
Cord relief
Electronic unit
Earth connection
Connector
Compressor
Screw 3.5 x 12 mm (3 pcs.)
Screw 3.5 x 25 mm (2 pcs.)

(for further descriptions on connecting the electronic unit and the


compressor, refer to instruction CI.42.D. "Electronic Unit Type
105N4001 - 198-254V for the TLV Compressor").

118-1917
118-1918
118-1919

CG.42.K4.02

CK.40.B6.02

July 2001

111

TLV6F
Variable Speed Drive Compressor
R134a
220-240V 50-60Hz
Data Sheet (Replaces CG.42.L3.02)
General
TLV6F

Code number: Comp. without electronic unit

102G4685

Code number: Electronic unit

105N4001

Application

102G

TLV6F

Application

R134a
SUCTION
CONNECTOR

Blue stripe

4685

Approvals

LBP

Barcode on
white background

-35 to -10

Yellow background

Application
Evaporating temperature range
Voltage range

C
V/Hz

HST

Comp. cooling at ambient temp.

DANFOSS COMPRESSORS

198 - 254 /50 - 60

Starting characteristics
Max. ambient temperature

8396-2

Compressor

43

32C

38C

43C

S
O
F1

= Static cooling normally sufficient


= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

F2

Features
Speed range

rpm

2000 - 4000

Control modes with

- mech. thermostat 220V ON/OFF

integrated speed control AEO*)

- 5V DC ON/OFF

External speed control

- 5V DC 200-400Hz

Protections

- current
- speed

204
186
178
170

- temperature
*)AEO - Adaptive Energy Optimizer

Design

16

9
3

Displacement

cm

Oil quantity

cm3

180

400

Free gas vol. in compressor


Weight: Compressor/Electronic unit

cm3

1790

kg

7.9/0.6

35
70
100

Maximum refrigerant charge

5.70

permanent magnet

Resistance, all 3 windings (25C)

14.0

Approvals

electronic cut-off
A B

105
107

105

Cut-in current HST

31.5
28

LRA (rated after 4 sec. UL984) HST

30

Motor type

230
176

Motor

EN 60335-2-34 with Annex AA

Dimensions
Height

mm

173

169

6.2 0.09

6.2 0.09

location/I.D. mm

5.0 +0.12/+0.20

Compressors on a pallet (without el. unit) pcs.


July 2001

112

125
CG.42.L4.02

CK.40.B6.02

102

29
71

location/I.D. mm

Discharge connector

51 20

Process connector

66

location/I.D. mm

45

Suction connector

157
120

8394

96
117

August 2001

Capacity (EN 12900/CECOMAF)


rpm \ C
2,000
2,500
3,000
4,000

-35
36.7
44.2
50.9
61.7

-30
53.4
64.8
75.1
92.9

watt

-25
74.5
90.4
105
132

-23.3
82.7
100
117
147

-20
100
122
142
179

-15
132
160
187
237

-25
91.8
111
130
162

-23.3
102
124
144
181

-20
124
150
175
221

-15
163
198
231
292

-10
210
254
297
378

-25
65.5
80.0
94.9
126

-23.3
69.7
85.0
101
134

-20
78.0
95.0
113
150

-15
91.5
111
132
175

-10
106
129
152
203

-25
1.28
1.28
1.27
1.24

-23.3
1.35
1.35
1.34
1.30

-20
1.47
1.48
1.47
1.41

-15
1.67
1.68
1.67
1.57

-10
1.86
1.89
1.88
1.73

Capacity (ASHRAE)
rpm \ C
2,000
2,500
3,000
4,000

-35
45.2
54.5
62.7
76.0

-30
65.9
79.9
92.6
115

-35
43.9
53.0
62.4
82.0

-30
54.1
66.0
78.2
104

-35
0.91
0.91
0.91
0.91

-30
1.09
1.09
1.09
1.07

6
10

7
8

-35
1.03
1.03
1.01
0.93

-30
0.99
0.98
0.96
0.90

-25
1.14
1.13
1.11
1.04

-23.3
1.19
1.18
1.16
1.09

-20
1.29
1.28
1.26
1.20

-15
1.44
1.44
1.42
1.35

-30
1.22
1.21
1.19
1.10

-25
1.40
1.39
1.37
1.29

-23.3
1.46
1.46
1.43
1.35

-20
1.59
1.58
1.56
1.48

-15
1.78
1.78
1.75
1.67

-10
1.61
1.60
1.58
1.50

R+
R-

3
4

f 5

EN 12900/CECOMAF
55C
32C
55C

Legend

-10
1.99
1.98
1.95
1.86

ASHRAE
55C
32C
32C

Accessories
Devices
Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities

August 2001

L
N
N
C
C
L
N

W/W

Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Static cooling, 220V 50Hz

13

W/W

COP (ASHRAE)
rpm \ C
2,000
2,500
3,000
4,000

13

8
7

11

-35
0.84
0.83
0.82
0.75

8385-2

14

COP (EN 12900/CECOMAF)


rpm \ C
2,000
2,500
3,000
4,000

watt

Current consumption
rpm \ C
2,000
2,500
3,000
4,000

12
13

watt

Power consumption
rpm \ C
2,000
2,500
3,000
4,000

-10
170
206
240
306

TLV6F

Number

Description

1:
2:
3:
4:
5:
6:
7:
8:
9:
10:
11:
12:
13:
14:

Power supply
Fan connection
Thermostat connection
Light connection
Signal input
Mounting recesses
Cover
Cord relief
Electronic unit
Earth connection
Connector
Compressor
Screw 3.5 x 12 mm (3 pcs.)
Screw 3.5 x 25 mm (2 pcs.)

(for further descriptions on connecting the electronic unit and the


compressor, refer to instruction CI.42.D. "Electronic Unit Type
105N4001 - 198-254V for the TLV Compressor").

118-1917
118-1918
118-1919

CG.42.L4.02

CK.40.B6.02

July 2001

113

TLV7F
Variable Speed Drive Compressor
R134a
220-240V 50-60Hz
Data Sheet (Replaces CG.42.M3.02)
General
TLV7F

Code number: Comp. without electronic unit

102G4785

Code number: Electronic unit

105N4001

Application

102G

TLV7F

Application

R134a
SUCTION
CONNECTOR

Blue stripe

4785

Approvals

LBP

Barcode on
white background

-35 to -10

Yellow background

Application
Evaporating temperature range
Voltage range

C
V/Hz

HST

Comp. cooling at ambient temp.

DANFOSS COMPRESSORS

198 - 254 /50 - 60

Starting characteristics
Max. ambient temperature

8396-3

Compressor

43

32C

38C

43C

S
O
F1

= Static cooling normally sufficient


= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

F2

Features
Speed range

rpm

2000 - 4000

Control modes with

- mech. thermostat 220V ON/OFF

integrated speed control AEO*)

- 5V DC ON/OFF

External speed control

- 5V DC 200-400Hz

Protections

- current
- speed

204
186
178
170

- temperature
*)AEO - Adaptive Energy Optimizer

Design

16

9
3

Displacement

cm

Oil quantity

cm3

180

400

Free gas vol. in compressor


Weight: Compressor/Electronic unit

cm3

1790

kg

7.9/0.6

35
70
100

Maximum refrigerant charge

6.49

permanent magnet

Resistance, all 3 windings (25C)

14.0

Approvals

electronic cut-off
A B

105
107

105

Cut-in current HST

31.5
28

LRA (rated after 4 sec. UL984) HST

30

Motor type

230
176

Motor

EN 60335-2-34 with Annex AA

Dimensions
Height

mm

173

169

6.2 0.09

6.2 0.09

location/I.D. mm

5.0 +0.12/+0.20

Compressors on a pallet (without el. unit) pcs.


July 2001

114

125
CG.42.M4.02

CK.40.B6.02

102

29
71

location/I.D. mm

Discharge connector

51 20

Process connector

66

location/I.D. mm

45

Suction connector

157
120

8394

96
117

August 2001

Capacity (EN 12900/CECOMAF)


rpm \ C
2,000
2,500
3,000
4,000

-35
47.5
56.3
64.2
78.3

-30
66.2
80.7
92.8
111

watt

-25
90.0
111
128
153

-23.3
99.3
122
141
170

-20
120
147
171
205

-15
156
192
222
269

-25
111
137
158
189

-23.3
123
151
175
210

-20
148
182
211
253

-15
192
237
274
332

-10
246
302
350
427

-25
78.3
97.6
115
146

-23.3
83.3
104
123
155

-20
93.1
116
137
174

-15
109
136
161
203

-10
125
156
185
235

-25
1.46
1.48
1.47
1.38

-23.3
1.53
1.55
1.55
1.45

-20
1.68
1.70
1.69
1.57

-15
1.91
1.93
1.92
1.73

-10
2.14
2.17
2.15
1.88

Capacity (ASHRAE)
rpm \ C
2,000
2,500
3,000
4,000

-35
58.6
69.3
79.1
96.6

-30
81.7
99.5
114
137

-35
51.8
63.0
74.2
96.2

-30
64.6
79.8
94.2
120

-35
1.05
1.05
1.05
0.97

-30
1.25
1.26
1.26
1.18

6
10

7
8

-35
1.13
1.10
1.07
1.00

-30
1.03
1.01
0.99
0.93

-25
1.15
1.13
1.11
1.05

-23.3
1.19
1.18
1.15
1.09

-20
1.28
1.27
1.24
1.18

-15
1.43
1.41
1.38
1.32

-30
1.27
1.25
1.22
1.14

-25
1.42
1.40
1.37
1.29

-23.3
1.47
1.45
1.42
1.35

-20
1.59
1.56
1.53
1.46

-15
1.77
1.74
1.71
1.63

-10
1.59
1.57
1.53
1.47

R+
R-

3
4

f 5

EN 12900/CECOMAF
55C
32C
55C

Legend

-10
1.97
1.94
1.90
1.81

ASHRAE
55C
32C
32C

Accessories
Devices
Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities

August 2001

L
N
N
C
C
L
N

W/W

Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Static cooling, 220V 50Hz

13

W/W

COP (ASHRAE)
rpm \ C
2,000
2,500
3,000
4,000

13

8
7

11

-35
0.92
0.89
0.87
0.81

8385-2

14

COP (EN 12900/CECOMAF)


rpm \ C
2,000
2,500
3,000
4,000

watt

Current consumption
rpm \ C
2,000
2,500
3,000
4,000

12
13

watt

Power consumption
rpm \ C
2,000
2,500
3,000
4,000

-10
199
245
284
345

TLV7F

Number

Description

1:
2:
3:
4:
5:
6:
7:
8:
9:
10:
11:
12:
13:
14:

Power supply
Fan connection
Thermostat connection
Light connection
Signal input
Mounting recesses
Cover
Cord relief
Electronic unit
Earth connection
Connector
Compressor
Screw 3.5 x 12 mm (3 pcs.)
Screw 3.5 x 25 mm (2 pcs.)

(for further descriptions on connecting the electronic unit and the


compressor, refer to instruction CI.42.D. "Electronic Unit Type
105N4001 - 198-254V for the TLV Compressor").

118-1917
118-1918
118-1919

CG.42.M4.02

CK.40.B6.02

July 2001

115

TLS3FT
Tropical Compressor
R134a
220-240V 50Hz
Data Sheet (Replaces CD.42.N5.02)
General
TLS3FT

Code number

102G4324

Application

R134a
SUCTION
CONNECTOR

Blue stripe

Application

102G

TLS3FT

4324

Approvals

Application

LBP

Evaporating temperature range

Voltage range

-35 to -10

V/Hz

Barcode on
white background

8281

Compressor

DANFOSS COMPRESSORS

Yellow background

187 - 254 /50


RSIR*)

Motor type
Max. ambient temperature
Comp. cooling at ambient temp.

43

32C

38C

43C

S
O
F1
F2

= Static cooling normally sufficient


= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

*) In capillary tube systems where non-equalized pressures


may occur at compressor start, or in areas with short power
supply drop-outs, a starting capacitor can be used for ensuring a successful start (CSIR).

Design
Displacement

cm3

3.13

Oil quantity

cm3

180

Maximum refrigerant charge


Free gas vol. in compressor

400

cm3

1790

kg

7.5

16

35
70
100

Weight without electrical equipment

Motor
Motor size

watt

75

LRA (rated after 4 sec. UL984) LST

2.6

Cut-in current LST

6.9

Resistance, main and start winding (25C)

9
170
178
186
204

27.5/15.1

Approvals

EN 60335-2-34

222
176

E
Dimensions

6.2 0.09

Process connector

location/I.D. mm

6.2 0.09

Discharge connector

location/I.D. mm

5.0 +0.12/+0.20

Compressors on a pallet

pcs.

A B

105
107

location/I.D. mm

30

173
169

105

A
B

Suction connector

mm

31.5
28

Height

125

102

June 2001

116

CD.42.N6.02

CK.40.B6.02

71

29

51 20

45

157
60.5
66

8244

96
117

August 2001

Capacity (EN 12900/CECOMAF)


Comp.\C
TLS3FT

-35
21

-30
34

-25
50

watt
-23.3
56

-20
69

-15
92

-10
120

HST
c

Capacity (ASHRAE)
Comp.\C
TLS3FT

-35
26

watt

-30
42

-25
61

-23.3
69

-20
85

-15
114

-10
149
b

Power consumption
Comp.\C
TLS3FT

-35
45

watt

-30
53

-25
62

-23.3
65

-20
71

-15
81

8219

-10
92

a2
d

Current consumption
Comp.\C
TLS3FT

-35
0.39

-30
0.42

A
-25
0.45

-23.3
0.46

-20
0.48

-15
0.52

-10
0.56

c
11

10

COP (EN 12900/CECOMAF)


Comp.\C
TLS3FT

-35
0.46

W/W

-30
0.63

-25
0.80

-23.3
0.86

-20
0.97

-15
1.14

-10
1.30

-30
0.78

-25
0.99

-23.3
1.06

-20
1.20

-15
1.41

-10
1.61

COP (ASHRAE)
Comp.\C
TLS3FT

-35
0.57

12

13
14

W/W

Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Static cooling, 220V 50Hz,
PTC consumption incl.

EN 12900/CECOMAF
55C
32C
55C

Main winding

ASHRAE
55C
32C
32C

Winding protector Start winding

LST
g

b
8217

a1

Accessories
Devices

Fig.

TLS3FT

a1

103N0011
103N0018

Starting relay

a2

117U6007

Cover

103N2010

Starting capacitor 60 F

117U5014

Cord relief

103N1010

Protection screen for PTC

103N0476

PTC starting device

6.3 mm spades
4.8 mm spades

Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities

August 2001

Main winding a1 Start winding


N

118-1917
118-1918
118-1919

Winding protector

CD.42.N6.02

CK.40.B6.02

June 2001

117

TLS4FT
Tropical Compressor
R134a
220-240V 50Hz
Data Sheet (Replaces CD.42.X1.02)
General
TLS4FT

Code number

102G4424

Application

R134a
SUCTION
CONNECTOR

Blue stripe

Application

102G

TLS4FT

4424

Approvals

Application

LBP

Evaporating temperature range

Voltage range

-35 to -10

V/Hz

Barcode on
white background

8281-2

Compressor

DANFOSS COMPRESSORS

Yellow background

187 - 254 /50


RSIR*)

Motor type
Max. ambient temperature
Comp. cooling at ambient temp.

43

32C

38C

43C

S
O
F1
F2

= Static cooling normally sufficient


= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

*) In capillary tube systems where non-equalized pressures


may occur at compressor start, or in areas with short power
supply drop-outs, a starting capacitor can be used for ensuring a successful start (CSIR).

Design
Displacement

cm3

Oil quantity

cm3

180

400

cm3

1790

kg

7.5

Maximum refrigerant charge


Free gas vol. in compressor

16

35
70
100

Weight without electrical equipment

3.86

Motor
Motor size

watt

125

LRA (rated after 4 sec. UL984) LST/HST

4.9/5.8

Cut-in current LST/HST

8.7/5.8

Resistance, main and start winding (25C)

9
170
178
186
204

16.0/17.0

Approvals

EN 60335-2-34

222
176

Dimensions
169

6.2 0.09

Process connector

location/I.D. mm

6.2 0.09

Discharge connector

location/I.D. mm

5.0 +0.12/+0.20

Compressors on a pallet

pcs.

30

173

A B

105
107

location/I.D. mm

105

Suction connector

mm

31.5
28

Height

125

102

June 2001

118

CD.42.X2.02

CK.40.B6.02

71

29

51 20

45

157
60.5
66

8244

96
117

August 2001

Capacity (EN 12900/CECOMAF)


Comp.\C
TLS4FT

-35
27

-30
43

-25
63

watt
-23.3
71

-20
88

-15
117

-10
152

HST
c

Capacity (ASHRAE)
Comp.\C
TLS4FT

-35
34

watt

-30
53

-25
78

-23.3
88

-20
108

-15
144

-10
188
b

Power consumption
Comp.\C
TLS4FT

-35
68

watt

-30
77

-25
87

-23.3
91

-20
99

-15
110

8219

-10
123

a2
d

Current consumption
Comp.\C
TLS4FT

-35
0.78

-30
0.79

A
-25
0.82

-23.3
0.82

-20
0.84

-15
0.87

-10
0.91

c
11

10

COP (EN 12900/CECOMAF)


Comp.\C
TLS4FT

-35
0.40

W/W

-30
0.56

-25
0.72

-23.3
0.78

-20
0.89

-15
1.06

-10
1.24

-30
0.69

-25
0.89

-23.3
0.96

-20
1.10

-15
1.31

-10
1.53

COP (ASHRAE)
Comp.\C
TLS4FT

-35
0.49

12

13
14

W/W

Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Static cooling, 220V 50Hz,
PTC consumption incl.

EN 12900/CECOMAF
55C
32C
55C

Main winding

ASHRAE
55C
32C
32C

Winding protector Start winding

LST
g

b
8217

a1

Accessories
Devices

Fig.

TLS4FT

a1

103N0011
103N0018

Starting relay

a2

117U6004

Cover

103N2010

Starting capacitor 60 F

117U5014

Cord relief

103N1010

Protection screen for PTC

103N0476

PTC starting device

6.3 mm spades
4.8 mm spades

Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities

August 2001

Main winding a1 Start winding


N

118-1917
118-1918
118-1919

Winding protector

CD.42.X2.02

CK.40.B6.02

June 2001

119

TLS5FT
Tropical Compressor
R134a
220-240V 50Hz
Data Sheet (Replaces CD.42.Y1.02)
General
TLS5FT

Code number

102G4524

Code number

102G4527

Application

102G

TLS5FT
R134a
SUCTION
CONNECTOR

Blue stripe

4524

Approvals

Application
Application

Barcode on
white background

LBP

Evaporating temperature range

Voltage range

187 - 254 /50


RSIR*)

Motor type

Comp. cooling at ambient temp.

DANFOSS COMPRESSORS

Yellow background

-35 to -10

V/Hz

Max. ambient temperature

8281-3

Compressor

43

32C

38C

43C

S
O
F1
F2

= Static cooling normally sufficient


= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

*) In capillary tube systems where non-equalized pressures


may occur at compressor start, or in areas with short power
supply drop-outs, a starting capacitor can be used for ensuring a successful start (CSIR).

Design
Displacement

cm3

Oil quantity

cm3

180

400

cm3

1790

kg

7.5

Maximum refrigerant charge


Free gas vol. in compressor

16

35
70
100

Weight without electrical equipment

5.08

Motor
Motor size

watt

LRA (rated after 4 sec. UL984) LST/HST

140

170
178
186
204

5.4/5.7

Cut-in current LST/HST

9.7/5.7

Resistance, main and start winding (25C)

14.5/14.8

E
30

102G4527

173

169

A B

105
107

102G4524
mm

222
176

31.5
28

Dimensions
Height

EN 60335-2-34

105

Approvals

Suction connector

location/I.D. mm

C 6.2 0.09

Process connector

location/I.D. mm

D 6.2 0.09

6.5 0.09
6.5 0.09

Discharge connector

location/I.D. mm

E 5.0 +0.12/+0.20

5.0 +0.12/+0.20

May 2001

120

CD.42.Y2.02

CK.40.B6.02

71

45

102

29

125

51 20

pcs.

157
60.5
66

8244

Compressors on a pallet

96
117

August 2001

Capacity (EN 12900/CECOMAF)


Comp.\C
TLS5FT

-35
47.8

-30
70.7

-25
98.0

watt
-23.3
109

-20
131

-15
170

-10
216

HST
c

Capacity (ASHRAE)
Comp.\C
TLS5FT

-35
58.9

watt

-30
87.2

-25
121

-23.3
134

-20
161

-15
209

-10
267
b

Power consumption
Comp.\C
TLS5FT

-35
84.5

watt

-30
99.2

-25
114

-23.3
120

-20
131

-15
147

8219

-10
165

a2
d

Current consumption
Comp.\C
TLS5FT

-35
0.96

-30
0.98

A
-25
1.01

-23.3
1.02

-20
1.05

-15
1.10

-10
1.15

c
11

10

COP (EN 12900/CECOMAF)


Comp.\C
TLS5FT

-35
0.57

W/W

-30
0.71

-25
0.86

-23.3
0.91

-20
1.00

-15
1.15

-30
0.88

-25
1.06

-23.3
1.12

-20
1.24

-15
1.42

COP (ASHRAE)
Comp.\C
TLS5FT

-35
0.70

-10
1.30

12

13
14

W/W

Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Static cooling, 220V 50Hz,
PTC consumption incl.

EN 12900/CECOMAF
55C
32C
55C

-10
1.61

Main winding

ASHRAE
55C
32C
32C

Winding protector Start winding

LST
g

b
8217

a1

Accessories
Devices

Fig.

TLS5FT

a1

103N0011
103N0018

Starting relay

a2

117U6000

PTC starting device

6.3 mm spades
4.8 mm spades

Cover

103N2010

Starting capacitor 60 F

117U5014

Cord relief

103N1010

Protection screen for PTC

103N0476

Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities

August 2001

Main winding a1 Start winding


N

118-1917
118-1918
118-1919

Winding protector

CD.42.Y2.02

CK.40.B6.02

May 2001

121

TFS4FT
Tropical Compressor
R134a
220V 50Hz
Data Sheet (Replaces CD.42.U3.22)
General
TFS4FT

Connector-material

Sealing

Copper-plated steel

Aluminium caps

Copper-plated steel

Rubber plugs

Copper

Rubber plugs

Application

102G

TFS4FT

Code number

R134a
SUCTION
CONNECTOR

Blue stripe

102G4430

4430

Barcode on
white background

DANFOSS COMPRESSORS

8321

Compressor

Yellow background

Application
Application

LBP

Evaporating temperature range

F (C)

Voltage range

-31 to 23 (-35 to -5)

V/Hz

176 - 242 /50

Motor type

RSIR

Max. ambient temperature

F (C)

110 (43)

Comp. cooling at

S
O
F1
F2

max. ambient temperature

110F (43C)

= Static cooling normally sufficient


= Oil cooling
= Fan cooling 1.5 m/s (compressor compartment
temperature equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

Design
Displacement

cu.in. (cm3)

Oil quantity

fl.oz. (cm3)

6.1 (180)

oz. (g)

14.0 (400)

14.9 (6.8)

4.02"(102)

Motor
A

7.4

Cut-in current LST

7.4

Resistance, main and start winding (77F)

(29)

D
E

19.3/38.1

Approvals

8246

8.90"(226)
6.93"(176)

A B

4.13"(105)
4.21"(107)

LRA (rated after 4 sec.UL984) LST

30

90

31.5
28

watt

4.13"(105)

Motor size

3.78"(96)
4.61"(117)

1.14"

51 20

6.18"(157)

57.3 (1690)

lbs. (kg)

2.80"(71)

Weight without electrical equipment

45

Free gas vol. in compressor housing fl.oz. (cm3)

2.34"(59.5)
2.60" (66)

Maximum refrigerant charge

0.23 (3.86)

Dimensions
B

6.50 (166)

Suction connector

location/I.D. in. (mm) C

0.252-0.259 (6.50.09)

Process connector

location/I.D. in. (mm) D

0.252-0.259 (6.50.09)

Discharge connector

location/I.D. in. (mm) E 0.202-0.205 (5.0+0.12/0.20)

Compressors on a pallet

pcs.

0.75"(19)

6.50"(165)

0.63"(16)

0.14"(3.6)
5.35"(136)

6.70 (170)

2.76"(70)

in. (mm) A

4.00"(101.6)

Height

125
6.70"(170)
7.01"(178)
8.03"(204)

July 2001

122

CG.42.U4.22

CK.40.B6.02

August 2001

Capacity (ASHRAE)
Comp.\F
Comp.\C
TFS4FT

-30
-34.4
154

-20
-28.9
234

Btu/h
-13
-25
303

-10
-23.3
335

0
-17.8
461

10
-12.2
615

14
-10
685

20
-6.7
800
a2

Capacity (EN 12900/CECOMAF)


Comp.\C
Comp.\F
TFS4FT

-34.4
-30
37

-28.9
-20
56

watt

-25
-13
72

-23.3
-10
80

-17.8
0
110

-12.2
10
147

-10
14
164

-13
-25
84

-10
-23.3
87

0
-17.8
100

10
-12.2
114

14
-10
120

-6.7
20
191

Power consumption
Comp.\F
Comp.\C
TFS4FT

-30
-34.4
68

-20
-28.9
77

-30
-34.4
0.68

-20
-28.9
0.70

8230

watt
20
-6.7
130

Current consumption
Comp.\F
Comp.\C
TFS4FT

a2

A
-13
-25
0.72

-10
-23.3
0.73

0
-17.8
0.76

10
-12.2
0.81

14
-10
0.82

20
-6.7
0.85

10
12

Main winding

EER (ASHRAE)
Comp.\F
Comp.\C
TFS4FT

-30
-34.4
2.27

-34.4
-30
0.54

Start winding
Thermostat

14

Btu/Wh
-20
-28.9
3.06

-13
-25
3.62

-10
-23.3
3.85

0
-17.8
4.63

10
-12.2
5.39

14
-10
5.69

-23.3
-10
0.92

-17.8
0
1.11

-12.2
10
1.29

-10
14
1.36

20
-6.7
6.16

COP (EN 12900/CECOMAF)


Comp.\C
Comp.\F
TFS4FT

11
13

-28.9
-20
0.73

Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Static cooling, 220V 50Hz

-25
-13
0.87

Motor protector

W/W

ASHRAE
130F (54,4C)
90F (32C)
90F (32C)

-6.7
20
1.47

EN 12900/CECOMAF
55C (131F)
32C (90F)
55C (131F)

Accessories
Devices

Fig.

TFS4FT

Starting relay (Klixon incl.)

a2

117U4109
MRP209HL-6

Klixon
Cover

117U1023

Cord relief

117U0349

Mounting accessories
Bolt joint in quantities
Bolt joint in quantities
Snap-on in quantities

August 2001

in. (mm)
5
/8 (16)
3
/4 (19)
5
/8 (16)

118-1945
118-1948
118-1944

CD.42.U4.22

CK.40.B6.02

July 2001

123

TFS4.5FT
Tropical Compressor
R134a
220V 50Hz
Data Sheet
General
TFS4.5FT

Connector-material

Sealing

Copper-plated steel

Aluminium caps

Copper-plated steel

Rubber plugs

Copper

Rubber plugs

Application

102G

TFS4.5FT

Code number

R134a
SUCTION
CONNECTOR

Blue stripe

102G4431

4431

Barcode on
white background

DANFOSS COMPRESSORS

8431

Compressor

Yellow background

Application
Application

LBP

Evaporating temperature range

F (C)

Voltage range

-31 to 23 (-35 to -5)

V/Hz

176 - 242 /50

Motor type

RSIR

Max. ambient temperature

F (C)

110 (43)

Comp. cooling at

S
O
F1
F2

max. ambient temperature

110F (43C)

= Static cooling normally sufficient


= Oil cooling
= Fan cooling 1.5 m/s (compressor compartment
temperature equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

Design
cu.in. (cm3)

Weight without electrical equipment

14.9 (6.8)

4.02"(102)

Motor
A

9.4

Cut-in current LST

9.4

Resistance, main and start winding (77F)

D
E

13.5/34.3

Approvals

8246

8.90"(226)
6.93"(176)

A B

4.13"(105)
4.21"(107)

LRA (rated after 4 sec.UL984) LST

30

120

31.5
28

watt

4.13"(105)

Motor size

3.78"(96)
4.61"(117)

(29)

57.3 (1690)

lbs. (kg)

45

Free gas vol. in compressor housing fl.oz. (cm3)

1.14"

14.0 (400)

2.80"(71)

6.1 (180)

oz. (g)

Maximum refrigerant charge

51 20

0.29 (4.63)

fl.oz. (cm3)

6.18"(157)

Oil quantity

2.34"(59.5)
2.60" (66)

Displacement

Dimensions
B

6.50 (166)

Suction connector

location/I.D. in. (mm) C

0.252-0.259 (6.50.09)

Process connector

location/I.D. in. (mm) D

0.252-0.259 (6.50.09)

Discharge connector

location/I.D. in. (mm) E 0.202-0.205 (5.0+0.12/0.20)

Compressors on a pallet

pcs.

0.75"(19)

6.50"(165)

0.63"(16)

0.14"(3.6)
5.35"(136)

6.70 (170)

2.76"(70)

in. (mm) A

4.00"(101.6)

Height

125
6.70"(170)
7.01"(178)
8.03"(204)

July 2001

124

CG.42.W1.22

CK.40.B6.02

August 2001

Capacity (ASHRAE)
Comp.\F
Comp.\C
TFS4.5FT

-30
-34.4
199

-20
-28.9
296

Btu/h
-13
-25
379

-10
-23.3
418

0
-17.8
569

10
-12.2
754

14
-10
839

20
-6.7
977
a2

Capacity (EN 12900/CECOMAF)


Comp.\C
Comp.\F
TFS4.5FT

-34.4
-30
48

-28.9
-20
71

watt

-25
-13
91

-23.3
-10
100

-17.8
0
136

-12.2
10
180

-10
14
200

-13
-25
107

-10
-23.3
111

0
-17.8
125

10
-12.2
140

14
-10
146

-6.7
20
233

Power consumption
Comp.\F
Comp.\C
TFS4.5FT

-30
-34.4
88

-20
-28.9
99

-30
-34.4
0.95

-20
-28.9
0.97

8230

watt
20
-6.7
156

Current consumption
Comp.\F
Comp.\C
TFS4.5FT

a2

A
-13
-25
0.99

-10
-23.3
1.00

0
-17.8
1.03

10
-12.2
1.07

14
-10
1.09

20
-6.7
1.12

10
12

Main winding

EER (ASHRAE)
Comp.\F
Comp.\C
TFS4.5FT

-30
-34.4
2.27

-34.4
-30
0.54

Start winding
Thermostat

14

Btu/Wh
-20
-28.9
2.99

-13
-25
3.52

-10
-23.3
3.75

0
-17.8
4.55

10
-12.2
5.38

14
-10
5.73

-23.3
-10
0.90

-17.8
0
1.09

-12.2
10
1.29

-10
14
1.37

20
-6.7
6.27

COP (EN 12900/CECOMAF)


Comp.\C
Comp.\F
TFS4.5FT

11
13

-28.9
-20
0.72

Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Static cooling, 220V 50Hz

-25
-13
0.84

Motor protector

W/W

ASHRAE
130F (54,4C)
90F (32C)
90F (32C)

-6.7
20
1.50

EN 12900/CECOMAF
55C (131F)
32C (90F)
55C (131F)

Accessories
Devices

Fig.

TFS4.5FT

Starting relay (Klixon incl.)

a2

117U4103
MRP77HL-6

Klixon
Cover

117U1023

Cord relief

117U0349

Mounting accessories
Bolt joint in quantities
Bolt joint in quantities
Snap-on in quantities

August 2001

in. (mm)
5
/8 (16)
3
/4 (19)
5
/8 (16)

118-1945
118-1948
118-1944

CG.42.W1.22

CK.40.B6.02

July 2001

125

NL6FT
Tropical Compressor
R134a
220-240V 50/60Hz
Data Sheet (Replaces CD.43.M6.02)
General
NL6FT

105G

NL6FT

Code number

105G6628

Code number

105G6632

Application

R134a

Blue stripe
Approvals

Application
Application
Evaporating temperature range
Voltage range

6628

Barcode on
white background

LBP

DANFOSS COMPRESSORS

Yellow background

8282-4

Compressor

-35 to -10

V/Hz

187 - 254 /50


198 - 254 /60

Max. ambient temperature


Comp. cooling at ambient temp.

Design

S
O
F1

RSIR*)

Motor type
C

43

32C

38C

43C

F2

= Static cooling normally sufficient


= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

*) In capillary tube systems where non-equalized pressures


may occur at compressor start, or in areas with short power
supply drop-outs, a starting capacitor can be used for ensuring a successful start (CSIR).

Displacement

cm3

Oil quantity

cm3

320

400

cm3

2360

kg

10.0

watt

155

Maximum refrigerant charge


Free gas vol. in compressor

204
170

100
70

Weight without electrical equipment

6.13

Motor
Motor size

16
178

LRA (rated after 4 sec. UL984) LST/HST

5.9/7.4

Cut-in current LST/HST

10.3/7.4

Resistance, main and start winding (25C)

205

12.6/12.4
EN 60335-2-34, CCIB

location/I.D. mm

C 6.2 0.09

Process connector

location/I.D. mm

D 6.2 0.09

6.5 0.09

Discharge connector

location/I.D. mm

E 5.0 +0.12/+0.20

5.0 +0.12/+0.20

pcs.

80

102.5
51

113

August 2001

126

CD.43.M7.02

CK.40.B6.02

75.5

8248

72

Compressors on a pallet

254

6.5 0.09

27

47

54
78

197
191

93.5

A
B

60.5

mm

105G6632

166

Suction connector

105G6628

15

A B

Dimensions

35

25

Approvals

Height

119
127

August 2001

Capacity (EN 12900/CECOMAF)


Comp.\C
NL6FT

-35
60

-30
84

-25
115

watt
-23.3
127

-20
152

-15
198

-10
253

HST
c

Capacity (ASHRAE)
Comp.\C
NL6FT

-35
74

watt

-30
104

-25
141

-23.3
156

-20
188

-15
244

-10
311
b

Power consumption
Comp.\C
NL6FT

-35
93

watt

-30
107

-25
123

-23.3
130

-20
142

-15
163

8219

-10
184

a2
d

Current consumption
Comp.\C
NL6FT

-35
0.77

-30
0.80

A
-25
0.84

-23.3
0.85

-20
0.89

-15
0.96

-10
1.04

c
11

10

COP (EN 12900/CECOMAF)


Comp.\C
NL6FT

-35
0.65

W/W

-30
0.79

-25
0.93

-23.3
0.98

-20
1.07

-15
1.22

-30
0.97

-25
1.15

-23.3
1.21

-20
1.32

-15
1.50

-10
1.37

COP (ASHRAE)
Comp.\C
NL6FT

-35
0.80

12

13
14

W/W

Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Static cooling, 220V 50Hz,
PTC consumption incl.

EN 12900/CECOMAF
55C
32C
55C

-10
1.69

Main winding

ASHRAE
55C
32C
32C

Winding protector Start winding

LST
g

b
8217

a1

Accessories

Devices

Fig.

NL6FT

a1

103N0011
103N0018

Starting relay

a2

117U6000
103N2010

PTC starting device

6.3 mm spades
4.8 mm spades

Cover

Starting capacitor 80 F

117U5015

Cord relief

103N1010

Protection screen for PTC

103N0476

Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities

August 2001

Main winding a1 Start winding


N

118-1917
118-1918
118-1919

Winding protector

CD.43.M7.02

CK.40.B6.02

August 2001

127

NL7FT
Tropical Compressor
R134a
220-240V 50Hz
Data Sheet (Replaces CG.43.L1.02)
General
NL7FT

Code number

105G6728

Code number compressor with oil cooler

105G6738

105G

NL7FT
Application

R134a

Blue stripe
Approvals

Application

LBP

Evaporating temperature range


Voltage range

187 - 254 /50


RSIR*)

Max. ambient temperature


Comp. cooling at ambient temp.

43

32C

38C

43C

O/F1

S
O
F1
F2

cm3

Oil quantity

cm3

320

400

cm3

2360

kg

10.0

Maximum refrigerant charge


Free gas vol. in compressor

7.27
204
170

100
70

Weight without electrical equipment

Motor
Motor size

watt

LRA (rated after 4 sec. UL984) LST/HST

175

16

6.8/8.1

Cut-in current LST/HST

11.4/8.1

Resistance, main and start winding (25C)

10.7/13.0

178
205

EN 60335-2-34, CCIB

6.2 0.09

Process connector

location/I.D. mm

6.2 0.09

Discharge connector

location/I.D. mm

5.0 +0.12/+0.20

Oil cooler

location/I.D. mm

5.0 +0.12/+0.20

40
102.5
75.5
51

113

128

CG.43.L2.02

CK.40.B6.02

F
8249

72

80

254

27

47

40
54
78

location/I.D. mm

60.5

191

Suction connector

pcs.

93.5

197

166

15

mm

35

A B

Dimensions

August 2001

E
C

25

Approvals

Compressors on a pallet

= Static cooling normally sufficient


= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

*) In capillary tube systems where non-equalized pressures


may occur at compressor start, or in areas with short power
supply drop-outs, a starting capacitor can be used for ensuring a successful start (CSIR).

Displacement

Height

DANFOSS COMPRESSORS

Yellow background

-35 to -10

V/Hz

Motor type

Design

6728

Barcode on
white background

Application

8282-2

Compressor

119
127

August 2001

Capacity (EN 12900/CECOMAF)


Comp.\C
NL7FT

-35
71

-30
100

-25
136

watt
-23.3
150

-20
181

-15
235

-10
299

HST
c

Capacity (ASHRAE)
Comp.\C
NL7FT

-35
87

watt

-30
123

-25
168

-23.3
185

-20
222

-15
289

-10
369
b

Power consumption
Comp.\C
NL7FT

-35
108

watt

-30
124

-25
145

-23.3
152

-20
168

-15
194

8219

-10
220

a2
d

Current consumption
Comp.\C
NL7FT

-35
0.86

-30
0.88

A
-25
0.94

-23.3
0.96

-20
1.01

-15
1.11

-10
1.21

c
11

10

COP (EN 12900/CECOMAF)


Comp.\C
NL7FT

-35
0.66

W/W

-30
0.81

-25
0.94

-23.3
0.99

-20
1.07

-15
1.21

-30
0.99

-25
1.16

-23.3
1.21

-20
1.32

-15
1.49

COP (ASHRAE)
Comp.\C
NL7FT

-35
0.81

-10
1.36

12

13
14

W/W

Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Static cooling, 220V 50Hz,
PTC consumption incl.

EN 12900/CECOMAF
55C
32C
55C

-10
1.68

Main winding

ASHRAE
55C
32C
32C

Winding protector Start winding

LST
g

b
8217

a1

Accessories

Devices

Fig.

NL7FT

a1

103N0011
103N0018

Starting relay

a2

117U6001
103N2010

PTC starting device

6.3 mm spades
4.8 mm spades

Cover

Starting capacitor 80 F

117U5015

Cord relief

103N1010

Protection screen for PTC

103N0476

Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities

August 2001

Main winding a1 Start winding


N

118-1917
118-1918
118-1919

Winding protector

CG.43.L2.02

CK.40.B6.02

August 2001

129

NL9FT
Tropical Compressor
R134a
220-240V 50Hz
Data Sheet (Replaces CD.43.N2.02)
General
Compressor

NL9FT

Code number

105G6828

Code number compressor with oil cooler

105G6838

Code number

105G6832

Blue stripe
Approvals

Code number compressor with oil cooler

105G6833

Barcode on
white background

105G

NL9FT
Application

6828

DANFOSS COMPRESSORS

Yellow background

8282

R134a

Application
Application

LBP

Evaporating temperature range


Voltage range

-35 to -10

V/Hz

S
O
F1

187 - 254 /50


RSIR*)

Motor type
Max. ambient temperature
Comp. cooling at ambient temp.

43

32C

38C

O/F1

43C

O/F1

F2

= Static cooling normally sufficient


= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

*) In capillary tube systems where non-equalized pressures


may occur at compressor start, or in areas with short power
supply drop-outs, a starting capacitor can be used for ensuring a successful start (CSIR).

Design
Displacement

cm3

Oil quantity

cm3

320

400

cm3

2360

kg

10.0

Free gas vol. in compressor


Weight without electrical equipment

100
70

Maximum refrigerant charge

204
170

8.35

16

Motor

215

8.1/8.2

Cut-in current LST/HST

12.8/8.2

8.9/12.0
A B

197

191

254

Suction connector

location/I.D. mm

C 6.2 0.09

Process connector

location/I.D. mm

D 6.2 0.09

6.5 0.09

Discharge connector

location/I.D. mm

E 5.0 +0.12/+0.20

5.0 +0.12/+0.20

Oil cooler

location/I.D. mm

F 5.0 +0.12/+0.20

5.0 +0.12/+0.20

Compressors on a pallet

pcs.

6.5 0.09

51

130

27

47

80
113

August 2001

F
8249

60.5

mm

166

Height

105G6828/38 105G6832/33

72

Dimensions

40
102.5
75.5

93.5

EN 60335-2-34, CCIB

15

Approvals

35

Resistance, main and start winding (25C)

40
54
78

watt

LRA (rated after 4 sec. UL984) LST/HST

25

Motor size

178
205

CD.43.N3.02

CK.40.B6.02

119
127

August 2001

Capacity (EN 12900/CECOMAF)


Comp.\C
NL9FT

-35
87

-30
120

-25
162

watt
-23.3
178

-20
213

-15
275

-10
350

HST
c

Capacity (ASHRAE)
Comp.\C
NL9FT

-35
107

watt

-30
148

-25
199

-23.3
219

-20
262

-15
339

-10
432
b

Power consumption
Comp.\C
NL9FT

-35
127

watt

-30
146

-25
169

-23.3
178

-20
195

-15
223

8219

-10
252

a2
d

Current consumption
Comp.\C
NL9FT

-35
1.18

-30
1.22

A
-25
1.28

-23.3
1.30

-20
1.36

-15
1.45

-10
1.55

c
11

10

COP (EN 12900/CECOMAF)


Comp.\C
NL9FT

-35
0.69

W/W

-30
0.82

-25
0.95

-23.3
1.00

-20
1.09

-15
1.24

-30
1.01

-25
1.17

-23.3
1.23

-20
1.34

-15
1.52

COP (ASHRAE)
Comp.\C
NL9FT

-35
0.84

-10
1.39

12

13
14

W/W

Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Static cooling, 220V 50Hz,
PTC consumption incl.

EN 12900/CECOMAF
55C
32C
55C

-10
1.72

Main winding

ASHRAE
55C
32C
32C

Winding protector Start winding

LST
g

b
8217

a1

Accessories

Devices

Fig.

NL9FT

a1

103N0011
103N0018

Starting relay

a2

117U6015
103N2010

PTC starting device

6.3 mm spades
4.8 mm spades

Cover

Starting capacitor 80 F

117U5015

Cord relief

103N1010

Protection screen for PTC

103N0476

Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities

August 2001

Main winding a1 Start winding


N

118-1917
118-1918
118-1919

Winding protector

CD.43.N3.02

CK.40.B6.02

August 2001

131

NL10FT
Tropical Compressor
R134a
220-240V 50Hz
Data Sheet (Replaces CG.43.I1.02)
General
NL10FT

Code number

105G6829

Code number

105G6837*

Code number compressor with oil cooler

105G6839
* Performance data established on 8.2 mm
suction line. Restrictions due to 6.2 mm
suction line can affect system performance.

105G

NL10FT
Application

R134a

Blue stripe
Approvals

6829

Barcode on
white background

DANFOSS COMPRESSORS

Yellow background

8282-3

Compressor

Application
Application

LBP

Evaporating temperature range


Voltage range

-35 to -10

V/Hz

RSIR*)

Motor type
Max. ambient temperature
Comp. cooling at ambient temp.

43

32C

F2

38C

O/F1

43C

O/F1

= Static cooling normally sufficient


= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

*) In capillary tube systems where non-equalized pressures


may occur at compressor start, or in areas with short power
supply drop-outs, a starting capacitor can be used for ensuring a successful start (CSIR).

cm3

10.10

Oil quantity

cm3

320

Maximum refrigerant charge


Free gas vol. in compressor
Weight without electrical equipment

400

cm3

2360

kg

10.5

204
170

100
70

Displacement

16

Motor
235

13.6/10.4

Resistance, main and start winding (25C)

8.2/14.7
EN 60335-2-34, CCIB

105G6829/39
mm

105G6837

203

197

254

Suction connector

location/I.D. mm

C 8.2 0.09

Process connector

location/I.D. mm

D 6.2 0.09

6.2 0.09

Discharge connector

location/I.D. mm

E 6.2 0.09

5.0 +0.12/+0.20

Oil cooler

location/I.D. mm

F 6.2 0.09

Compressors on a pallet

pcs.

80

8249

51

113

August 2001

132

6.2 0.09

60.5

Height

A B

15

Dimensions

C
35

Approvals

40
102.5
75.5

Cut-in current LST/HST

25

9.2/10.4

93.5

166

watt

LRA (rated after 4 sec. UL984) LST/HST

72

Motor size

178
205

CG.43.I2.02

CK.40.B6.02

27

47

40
54
78

Design

S
O
F1

187 - 254 /50

119
127

August 2001

Capacity (EN 12900/CECOMAF)


Comp.\C
NL10FT

-35
113

-30
158

-25
213

watt
-23.3
235

-20
281

-15
361

-10
455

HST
c

Capacity (ASHRAE)
Comp.\C
NL10FT

-35
138

watt

-30
194

-25
262

-23.3
289

-20
345

-15
445

-10
561
b

Power consumption
Comp.\C
NL10FT

-35
159

watt

-30
184

-25
217

-23.3
229

-20
254

-15
292

8219

-10
327

a2
d

Current consumption
Comp.\C
NL10FT

-35
1.33

-30
1.39

A
-25
1.48

-23.3
1.52

-20
1.60

-15
1.74

-10
1.88

c
11

10

COP (EN 12900/CECOMAF)


Comp.\C
NL10FT

-35
0.71

W/W

-30
0.85

-25
0.98

-23.3
1.02

-20
1.10

-15
1.24

-30
1.05

-25
1.21

-23.3
1.26

-20
1.36

-15
1.52

COP (ASHRAE)
Comp.\C
NL10FT

-35
0.87

-10
1.39

12

13
14

W/W

Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Static cooling, 220V 50Hz,
PTC consumption incl.

EN 12900/CECOMAF
55C
32C
55C

-10
1.71

Main winding

ASHRAE
55C
32C
32C

Winding protector Start winding

LST
g

b
8217

a1

Accessories

Devices

Fig.

NL10FT

a1

103N0011
103N0018

Starting relay

a2

117U6002
103N2010

PTC starting device

6.3 mm spades
4.8 mm spades

Cover

Starting capacitor 80 F

117U5015

Cord relief

103N1010

Protection screen for PTC

103N0476

Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities

August 2001

Main winding a1 Start winding


N

118-1917
118-1918
118-1919

Winding protector

CG.43.I2.02

CK.40.B6.02

August 2001

133

SC12FT
Tropical Compressor
R134a
220-240V 50/60Hz
Data Sheet
General
SC12FT

Code number

104G8205

Code number compressor with oil cooler

104G8215

104G

SC12FT
Application

R134a

Blue stripe
Approvals

8205

Barcode on
white background

Application
Application

LBP

Evaporating temperature range

Voltage range

LBP: 187 - 254 /50


LBP: 198 - 254 /60

Motor type

S
O
F1

RSIR/CSIR
C

Comp. cooling at ambient temp.

DANFOSS COMPRESSORS

Yellow background

-35 to -5

V/Hz

Max. ambient temperature

8418

Compressor

43

32C

LBP: O/F1

38C

LBP: O/F1

43C

LBP: F2*)

F2

= Static cooling normally sufficient


= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

*) O/F1 possible at 220V nominal (187-242V)

Design
Displacement

cm3

Oil quantity

cm3 600 (550 on comp. with oil cooler)

Maximum refrigerant charge


Free gas vol. in compressor

1300

cm3

1510

kg

12.6

204
178
170

16

19
9.7

Motor
Motor size

watt

70
150

127
101.6
35

Weight without electrical equipment

12.87

315

LRA (rated after 4 sec. UL984) LST/HST

12.4/12.6

Cut-in current LST/HST

17.2/12.6

Resistance, main and start winding (25C)

6.7/11.8

Approvals

127
165
186
218

EN 60335-2-34

Dimensions

B1

183

B2

100

Suction connector

location/I.D. mm

8.2 0.09

Process connector

location/I.D. mm

6.2 0.09

Discharge connector

location/I.D. mm

6.2 0.09

Oil cooler

location/I.D. mm

6.2 0.09

Compressors on a pallet

pcs.

30

134

B2

255

37

37

80
107

February 2001

15
53

203

63

B A

B1

55
63

209

55

mm

151

Height

CG.44.C1.02

CK.40.B6.02

107
115

8264

August 2001

Capacity (EN 12900/CECOMAF)


Evap. temp in C
SC12FT, 50Hz
SC12FT, 60Hz

-35
103
125

watt

-30
163
192

-25
233
272

-23.3
259
302

-20
314
366

-15
408
477

-10
517
608

-30
201
237

-25
287
336

-23.3
320
373

-20
387
452

-15
503
589

-10
639
751

-30
226
245

-25
265
298

-23.3
278
316

-20
303
351

-15
341
405

-10
380
458

-5
422
511

-30
1.93
1.75

-25
2.04
1.92

-23.3
2.08
1.98

-20
2.17
2.10

-15
2.30
2.30

-10
2.45
2.50

-5
2.61
2.71

Capacity (ASHRAE)
Evap. temp in C
SC12FT, 50Hz
SC12FT, 60Hz

-35
126
153

-35
184
193

-35
1.84
1.58

8221

a1
d
Main winding

a1

Start winding

W/W

-35
0.56
0.64

-30
0.72
0.78

-25
0.88
0.91

-23.3
0.93
0.96

-20
1.03
1.04

-15
1.20
1.18

-10
1.36
1.33

-35
0.69
0.79

-30
0.89
0.97

-25
1.08
1.13

-23.3
1.15
1.18

-20
1.28
1.29

-15
1.48
1.46

-10
1.68
1.64

COP (ASHRAE)
Evap. temp in C
SC12FT, 50Hz
SC12FT, 60Hz

COP (EN 12900/CECOMAF)


Evap. temp in C
SC12FT, 50Hz
SC12FT, 60Hz

-5
798
942

watt

Current consumption
Evap. temp in C
SC12FT, 50Hz
SC12FT, 60Hz

HST

watt

Power consumption
Evap. temp in C
SC12FT, 50Hz
SC12FT, 60Hz

-5
645
761

-5
1.53
1.49

W/W

Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
50Hz: Fan cooling F2, 220V
60Hz: Fan cooling F2, 220V

EN 12900/CECOMAF
55C
32C
55C

-5
1.89
1.84

ASHRAE
55C
32C
32C

Winding protector

LST

b
8221

a1
d

Accessories

Main winding

Devices
PTC starting device

Fig.
6.3 mm spades

SC12FT

a1

103N0002

Starting relay

a2

117U6003

Cover

103N2009

Starting capacitor 80 F

117U5017

Cord relief

103N1004

Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities

August 2001

118-1917
118-1918
118-1919

CG.44.C1.02

CK.40.B6.02

a1

Start winding

Winding protector

February 2001

135

SC15FT
Tropical Compressor
R134a
220-240V 50/60Hz
Data Sheet
General
SC15FT

Code number

104G8505

Code number compressor with oil cooler

104G8515

104G

SC15FT
Application

R134a

Blue stripe
Approvals

8505

Barcode on
white background

Application
Application

LBP

Evaporating temperature range

Voltage range

LBP: 187 - 254 /50


LBP: 198 - 254 /60

Motor type

S
O
F1

RSIR/CSIR
C

Comp. cooling at ambient temp.

DANFOSS COMPRESSORS

Yellow background

-35 to -5

V/Hz

Max. ambient temperature

8418-2

Compressor

43

32C

LBP: O/F1

38C

LBP: O/F1

43C

LBP: F2*)

F2

= Static cooling normally sufficient


= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

*) O/F1 possible at 220V nominal (187-242V)

Design
Displacement

cm3

Oil quantity

cm3 600 (550 on comp. with oil cooler)

Maximum refrigerant charge


Free gas vol. in compressor

1300

cm3

1410

kg

13.1

204
178
170

16

19
9.7

Motor
Motor size

watt

70
150

127
101.6
35

Weight without electrical equipment

15.28

385

LRA (rated after 4 sec. UL984) LST/HST

15.5/14.8

Cut-in current LST/HST

19.9/14.8

Resistance, main and start winding (25C)

5.0/13.7

Approvals

127
165
186
218

EN 60335-2-34

Dimensions

B1

183

B2

100

Suction connector

location/I.D. mm

10.2 0.09

Process connector

location/I.D. mm

6.2 0.09

Discharge connector

location/I.D. mm

6.2 0.09

Oil cooler

location/I.D. mm

6.2 0.09

Compressors on a pallet

pcs.

30

136

B2

255

37

37

80
107

February 2001

15
53

203

63

B A

B1

55
63

209

55

mm

151

Height

CG.44.D1.02

CK.40.B6.02

107
115

8264

August 2001

Capacity (EN 12900/CECOMAF)


Evap. temp in C
SC15FT, 50Hz
SC15FT, 60Hz

-35
126
154

-30
197
235

-25
280
330

watt
-23.3
311
365

-20
376
441

-15
489
571

-10
620
724

-5
772
904

Capacity (ASHRAE)
Evap. temp in C
SC15FT, 50Hz
SC15FT, 60Hz

-35
155
189

HST
c

watt
-30
243
290

-25
345
407

-23.3
384
451

-20
465
544

-15
604
705

-10
766
895

-5
955
1118

b
8222

Power consumption
Evap. temp in C
SC15FT, 50Hz
SC15FT, 60Hz

-35
223
231

watt
-30
267
294

-25
311
356

-23.3
326
377

-20
356
418

-15
403
478

-10
451
537

Current consumption
Evap. temp in C
SC15FT, 50Hz
SC15FT, 60Hz

-35
2.22
1.87

-5
500
596

a2
d

A
-30
2.31
2.07

-25
2.42
2.27

-23.3
2.46
2.34

-20
2.54
2.48

-15
2.69
2.70

-10
2.86
2.93

-5
3.05
3.16

c
11

10

COP (EN 12900/CECOMAF)


Evap. temp in C
SC15FT, 50Hz
SC15FT, 60Hz

W/W

-35
0.56
0.66

-30
0.74
0.80

-25
0.90
0.92

-23.3
0.95
0.97

-20
1.06
1.05

-15
1.21
1.19

-10
1.38
1.35

-35
0.70
0.82

-30
0.91
0.98

-25
1.11
1.14

-23.3
1.18
1.19

-20
1.30
1.30

-15
1.50
1.48

-10
1.70
1.67

COP (ASHRAE)
Evap. temp in C
SC15FT, 50Hz
SC15FT, 60Hz

-5
1.54
1.52

12

13
14

W/W

Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
50Hz: Fan cooling F2, 220V
60Hz: Fan cooling F2, 220V

EN 12900/CECOMAF
55C
32C
55C

-5
1.91
1.88

ASHRAE
55C
32C
32C

Start winding
Main winding
Winding protector

LST

b
8221

a1
d

Accessories

Main winding

Devices
PTC starting device

Fig.
6.3 mm spades

SC15FT

a1

103N0002

Starting relay

a2

117U6005

Cover

103N2009

Starting capacitor 80 F

117U5017

Cord relief

103N1004

Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities

August 2001

118-1917
118-1918
118-1919

CG.44.D1.02

CK.40.B6.02

a1

Start winding

Winding protector

February 2001

137

SC18FTX
Tropical Compressor
R134a
220-240V 50/60Hz
Data Sheet
General
SC18FTX

Code number

104G8805

104G

SC18FTX
Application

R134a

Blue stripe
Approvals

Application
Application
Evaporating temperature range
Voltage range

C
V/Hz

LBP

Barcode on
white background

-35 to -5

Yellow background

8805

8418-3

Compressor

DANFOSS COMPRESSORS

LBP: 187 - 254 /50


LBP: 198 - 254 /60

Motor type

CSIR

Max. ambient temperature

Comp. cooling at ambient temp.

S
O
F1

43

32C

LBP: F2

38C

LBP: F2

43C

LBP: F2

Displacement

cm3

17.69

Oil quantity

cm3

600

F2

= Static cooling normally sufficient


= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

Design

Weight without electrical equipment

1300

cm3

1460

kg

13.7

Motor
Motor size

watt

495

LRA (rated after 4 sec. UL984) HST

18.6

Cut-in current HST

18.6

Resistance, main and start winding (25C)

3.7/14.1

Approvals

204
178
170

16

19
9.7

70
150

Free gas vol. in compressor

127
101.6
35

Maximum refrigerant charge

127
165
186
218

EN 60335-2-34

C
E

Dimensions
213

B1

193

B2

110

Suction connector

location/I.D. mm

10.2 0.09

Process connector

location/I.D. mm

6.2 0.09

Discharge connector

location/I.D. mm

6.2 0.09

pcs.

80

B2

255

55

Compressors on a pallet

B A

B1

63

219

37

37

107

February 2001

138

CG.44.E1.02

CK.40.B6.02

107
115

55
63

mm

151

Height

8257

August 2001

Capacity (EN 12900/CECOMAF)


Evap. temp in C
SC18FTX, 50Hz
SC18FTX, 60Hz

-35
144
187

-30
229
280

-25
325
390

watt
-23.3
361
432

-20
437
520

-15
567
675

-10
719
857

-5
896
1071

Capacity (ASHRAE)
Evap. temp in C
SC18FTX, 50Hz
SC18FTX, 60Hz

-35
178
230

watt
-30
282
345

-25
401
481

-23.3
445
532

-20
539
642

-15
700
834

-10
889
1060

-5
1108
1326

b
8222

Power consumption
Evap. temp in C
SC18FTX, 50Hz
SC18FTX, 60Hz

-35
257
274

watt
-30
313
348

-25
365
420

-23.3
383
444

-20
416
489

-15
466
557

-10
517
622

Current consumption
Evap. temp in C
SC18FTX, 50Hz
SC18FTX, 60Hz

-35
2.52
2.05

-5
571
686

a2
d

A
-30
2.69
2.36

-25
2.87
2.66

-23.3
2.94
2.77

-20
3.07
2.97

-15
3.27
3.28

-10
3.49
3.59

-5
3.72
3.90

c
11

10

COP (EN 12900/CECOMAF)


Evap. temp in C
SC18FTX, 50Hz
SC18FTX, 60Hz

W/W

-35
0.56
0.68

-30
0.73
0.80

-25
0.89
0.93

-23.3
0.94
0.97

-20
1.05
1.06

-15
1.22
1.21

-10
1.39
1.38

-35
0.69
0.84

-30
0.90
0.99

-25
1.10
1.15

-23.3
1.16
1.20

-20
1.30
1.31

-15
1.50
1.50

-10
1.72
1.70

COP (ASHRAE)
Evap. temp in C
SC18FTX, 50Hz
SC18FTX, 60Hz

-5
1.57
1.56

12

13
14

W/W

Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
50Hz: Fan cooling F2, 220V
60Hz: Fan cooling F2, 220V

EN 12900/CECOMAF
55C
32C
55C

-5
1.94
1.93

Start winding
Main winding
Winding protector

ASHRAE
55C
32C
32C

Accessories
Devices

Fig.

SC18FTX

Starting relay

a2

117U6019

Cover

103N2009

Starting capacitor 80 F

117U5017

Cord relief

103N1004

Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities

118-1917
118-1918
118-1919

CG.44.E1.02

August 2001

CK.40.B6.02

February 2001

139

SC21FTX
Tropical Compressor
R134a
220-240V 50/60Hz
Data Sheet
General
SC21FTX

Code number

104G8105

104G

SC21FTX
Application

R134a

Blue stripe
Approvals

Application
Application
Evaporating temperature range
Voltage range

C
V/Hz

LBP

Barcode on
white background

-35 to -5

Yellow background

8105

8418-4

Compressor

DANFOSS COMPRESSORS

LBP: 187 - 254 /50


LBP: 198 - 254 /60

Motor type

CSIR/CSR

Max. ambient temperature

Comp. cooling at ambient temp.

S
O
F1

43

32C

LBP: F2

38C

LBP: F2

43C

LBP: F2

Displacement

cm3

20.95

Oil quantity

cm3

600

F2

= Static cooling normally sufficient


= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

Design

Weight without electrical equipment

1300

cm3

1460

kg

13.5

Motor
Motor size

watt

550

LRA (rated after 4 sec. UL984) HST

21.8

Cut-in current HST

21.8

Resistance, main and start winding (25C)

3.3/19.0

Approvals

204
178
170

16

19
9.7

70
150

Free gas vol. in compressor

127
101.6
35

Maximum refrigerant charge

127
165
186
218

EN 60335-2-34 pending

C
E

Dimensions
213

B1

193

B2

110

Suction connector

location/I.D. mm

10.2 0.09

Process connector

location/I.D. mm

6.2 0.09

Discharge connector

location/I.D. mm

6.2 0.09

pcs.

80

B2

255

55

Compressors on a pallet

B A

B1

63

219

37

37

107

August 2001

140

CG.44.F1.02

CK.40.B6.02

107
115

55
63

mm

151

Height

8257

August 2001

Capacity (EN 12900/CECOMAF)


Evap. temp. in C
SC21FTX, 50Hz
SC21FTX, 60Hz

-35

-30

watt

-25
415
490

-23.3
450
530

-20

-15

-10

Capacity (ASHRAE)
Evap. temp. in C
SC21FTX, 50Hz
SC21FTX, 60Hz

-35

-5

watt
-30

-25
510
600

-23.3
550
650

-20

-15

-10

-5
b
8222

Power consumption
Evap. temp. in C
SC21FTX, 50Hz
SC21FTX, 60Hz

-35

watt
-30

-25
445
485

-23.3
460
530

-20

-15

-10

-5
d

Current consumption
Evap. temp. in C
SC21FTX, 50Hz
SC21FTX, 60Hz

-35

a2

A
-30

-25
3.44
2.33

-23.3
3.56
2.40

-20

-15

-10

-5
c
11

10

COP (EN 12900/CECOMAF)


Evap. temp. in C
SC21FTX, 50Hz
SC21FTX, 60Hz

-35

-30

W/W
-25
0.93
1.01

-23.3
0.98
1.06

-20

-25
1.14
1.24

-23.3
1.19
1.29

-20

-15

-10

12

13
14

COP (ASHRAE)
Evap. temp in C
SC21FTX, 50Hz
SC21FTX, 60Hz

-5

W/W
-35

Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
50Hz: Fan cooling F2, 220V
60Hz: Fan cooling F2, 220V
preliminary data

-30

EN 12900/CECOMAF
55C
32C
55C

-15

-10

-5

Start winding
Main winding
(pos.1)

Winding protector

ASHRAE
55C
32C
32C

a3
a2

Accessories
Devices

Fig.

50Hz (pos.1)

8227

Starting relay

a1

117Uxxxx

Starting capacitor 125 F

117U5018

Fig.

60Hz (pos.2)

a3

117-xxxx (xxx mm cable length)


117-xxxx (xxx mm cable length)
117-xxxx (xxx mm cable length)

Devices
Starting device

Starting relay

a2

Starting capacitor

Run capacitor

Devices

50 & 60Hz (pos.1 & pos.2)

Cover

103N2009

Cord relief

103N1004

August 2001

Start winding
5

a2

Main winding

Components of
starting device

Fig.

Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities

d
b

Winding
protector
1

2
N
L

2
N
L

Bleeder resistance

a3
M

(pos.2)

Thermostat

Fan

118-1917
118-1918
118-1919

CG.44.F1.02

CK.40.B6.02

August 2001

141

NLE9FT
Energy-optimized Tropical Compressor
R134a
220-240V 50Hz
Data Sheet
General
NLE9FT

Code number

105G6816

105G

NLE9FT
Application

R134a

Blue stripe
Approvals

Application
Application
Evaporating temperature range
Voltage range

C
V/Hz

LBP

Barcode on
white background

-35 to -10

Yellow background

6816

DANFOSS COMPRESSORS

8430-2

Compressor

187 - 254 /50

Motor type

RSIR

Max. ambient temperature

43

32C

38C

43C

Displacement

cm3

8.35

Oil quantity

cm3

320

Comp. cooling at ambient temp.

S
O
F1
F2

= Static cooling normally sufficient


= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

Design

Maximum refrigerant charge


Free gas vol. in compressor
Weight without electrical equipment

400

cm3

2360

kg

10.0

watt

234

204
170

Motor size
LRA (rated after 4 sec. UL984) LST

8.4

Cut-in current LST

13.1

Resistance, main and start winding (25C)

9.0/12.0

location/I.D. mm

6.2 0.09

Discharge connector

location/I.D. mm

5.0 +0.12/+0.20

102.5

Process connector

254
8248

CH.43.T1.02

CK.40.B6.02

27

47

54
78

51

72

166

60.5

80

113

142

75.5

6.2 0.09

pcs.

203
93.5

197

15

B
location/I.D. mm

July 2001

E
C
35

Compressors on a pallet

205

A B

mm

Suction connector

EN 60335-2-34 pending

Dimensions
Height

16
178

25

Approvals

100
70

Motor

119
127

August 2001

Capacity (EN 12900/CECOMAF)


Comp.\C
NLE9FT

-35

-30

-25
180

watt
-23.3
197

-20

-15

-10

Capacity (ASHRAE)
Comp.\C
NLE9FT

-35

watt

-30

-25
224

-23.3
245

-20

-15

-25
163

-23.3
173

-20

-25
1.20

-23.3
1.25

-20

-15

-10

8217

Power consumption
Comp.\C
NLE9FT

-35

watt

-30

-15

-35

-30

-35

-35

W/W

-30

-25
1.10

-23.3
1.14

-20

-15

-30

-25
1.37

-23.3
1.42

-20

-15

COP (ASHRAE)
Comp.\C
NLE9FT

Main winding a1 Start winding

A
-10

COP (EN 12900/CECOMAF)


Comp.\C
NLE9FT

a1

-10

Current consumption
Comp.\C
NLE9FT

-10

W/W

Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Static cooling, 220V 50Hz,
PTC consumption incl.,
preliminary data

EN 12900/CECOMAF
55C
32C
55C

-10

Winding protector

ASHRAE
55C
32C
32C

Accessories
Devices
PTC starting device

6.3 mm spades
4.8 mm spades

Fig.

NLE9FT

a1

103N0011
103N0018

Cover

103N2010

Cord relief

103N1010

Protection screen for PTC

103N0476

Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities

August 2001

118-1917
118-1918
118-1919

CH.43.T1.02

CK.40.B6.02

July 2001

143

PL35G
Universal Compressor
R134a
220-240V 50Hz
Data Sheet (Replaces CD.41.C6.02)
General
PL35G

PL35G

Code number

101G0250

Code number (UL-recognized)

101G0251

101G

Application

R134a

Blue stripe

0250

Approvals

Application

DANFOSS COMPRESSORS

Barcode on
white background

Application

MBP/HBP

Voltage range

Yellow background

-25 to 15

V/Hz

MBP: 198 - 254 /50

PL35G
230V-60Hz
1PH

MBP: 198 - 254 /60


HBP: 198 - 254 /50
Motor type

RSIR/CSIR

Max. ambient temperature


Comp. cooling at ambient temp.

THERMALLY
PROTECTED

38

32C

F2

38C

F2

S
O
F1

cm3

2.00

F2

Approval mark

Design
Displacement
Oil quantity

150

300

cm3

850

kg

4.3

cm

Maximum refrigerant charge


Free gas vol. in compressor
Weight without electrical equipment

= Static cooling normally sufficient


= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

204
170

Motor
watt

6.6/4.2

Resistance, main and start winding (25C)

38.0/14.0

Approvals (101G0250)

EN 60335-2-34

Approvals (101G0251)

UL984/CSA-C22.2, EN 60335-2-34

Dimensions

Suction connector

101G0250
mm

B1 B A

137

135

B1

128

B2

73

B2
206
8241

C 6.2 0.09

Process connector

location/I.D. mm

D 6.2 0.09

6.5 0.09

Discharge connector

location/I.D. mm

E 5.0 +0.12/+0.20

5.0 +0.12/+0.20

pcs.

16

101G0251

location/I.D. mm

Compressors on a pallet

100

Cut-in current LST/HST

54
2.1/4.2
35
70

6.5 0.09
46
59
130

LRA (rated after 4 sec. UL984) LST/HST

50
60.5

Motor size

Height

8283-3

Evaporating temperature range

8283

Compressor

150
127

August 2001

144

CD.41.C7.02

CK.40.B6.02

August 2001

Capacity (EN 12900/CECOMAF)


Evap. temp in C -25
PL35G, 50Hz
28.0
PL35G, 60Hz
34.0

-23.3
31.6
38.5

-20
39.3
47.9

watt
-15
53.0
63.8

-10
69.4
82.3

-5
89.0
104

0
112
129

5
140

7.2
153

10
172

HST
c

Capacity (ASHRAE)
Evap. temp in C -25
PL35G, 50Hz
34.5
PL35G, 60Hz
42.0

15
209

watt
-23.3
39.0
47.5

-20
48.5
59.1

-15
65.4
78.8

-10
85.8
102

-5
110
128

0
139
159

5
173

7.2
190

10
213

15
260

b
8225

Power consumption
Evap. temp in C -25
PL35G, 50Hz
48.0
PL35G, 60Hz
51.5

watt
-23.3
49.6
54.8

-20
53.2
61.0

-15
59.5
70.2

-10
66.6
79.1

-5
74.3
87.8

0
82.2
96.4

5
90.0

7.2
93.4

10
97.5

15
104

-20
0.48
0.44

-15
0.50
0.45

-10
0.52
0.47

-5
0.54
0.49

0
0.57
0.51

5
0.59

7.2
0.61

10
0.63

15
0.66

Current consumption
Evap. temp in C -25
PL35G, 50Hz
0.46
PL35G, 60Hz
0.43

a2
d

-23.3
0.47
0.43

c
11

10

12

COP (EN 12900/CECOMAF)


Evap. temp in C -25
PL35G, 50Hz
0.58
PL35G, 60Hz
0.66

-23.3
0.64
0.70

W/W
-20
0.74
0.78

-15
0.89
0.91

-10
1.04
1.04

-5
1.20
1.18

0
1.37
1.33

5
1.55

7.2
1.64

10
1.76

15
2.00
Main winding

COP (ASHRAE)
Evap. temp in C -25
PL35G, 50Hz
0.72
PL35G, 60Hz
0.82

Winding protector

W/W
-23.3
0.79
0.87

Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
50Hz: Fan cooling F2, 220V
60Hz: Fan cooling F2, 220V

-20
0.91
0.97

-15
1.10
1.12

-10
1.29
1.29

EN 12900/CECOMAF
55C
32C
55C

-5
1.48
1.46

0
1.69
1.65

13
14

5
1.93

7.2
2.04

10
2.19

Start winding

15
2.49

LST

ASHRAE
55C
32C
32C

b
8224

a1

Accessories
Devices

Fig.

PL35G

a1

103N0011
103N0018

Starting relay

a2

117U6021

Cover

103N0491

Starting capacitor 60 F

117U5014

Cord relief

103N1010

Protection screen for PTC

103N0476

PTC starting device

6.3 mm spades
4.8 mm spades

Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities

August 2001

118-1917
118-1918
118-1919

CD.41.C7.02

CK.40.B6.02

d
Main winding a1 Start winding
N

Winding protector

August 2001

145

TL2.5G
Universal Compressor
R134a
220-240V 50/60Hz
Data Sheet
General
Sealing

Copper-plated steel

Aluminium caps

Copper-plated steel

Rubber plugs

Copper

Rubber plugs

102G

TL2.5G

TL2.5G

Connector-material

Application

Code number

R134a

Blue stripe
Approvals

102G4250

4250

Barcode on
white background

DANFOSS COMPRESSORS

Yellow background

8284-6

Compressor

Application
Application

LBP/HBP

Evaporating temperature range

F (C)

Voltage range

-31 to 59 (-35 to 15)

V/Hz

LBP: 187 - 254 /50


HBP: 198 - 254 /50
LBP: 198 -254 /60
HBP: 207 - 254 /60

Motor type

RSIR/CSIR

Max. ambient temperature

F (C)

S
O
F1
F2

= Static cooling normally sufficient


= Oil cooling
= Fan cooling 1.5 m/s (compressor compartment
temperature equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

110 (43)

Comp. cooling at
max. ambient temperature

100F (38C)

LBP/HBP: S

110F (43C)

LBP: S

Free gas vol. in compressor housing fl.oz. (cm3)


Weight without electrical equipment

54.3 (1600)

lbs. (kg)

14.7 (6.7)

4.02"(102)

C or
D

3.78"(96)
4.61"(117)

(29)

14.0 (400)

1.14"

9.5 (280)

oz. (g)

Maximum refrigerant charge

0.16 (2.61)

2.80"(71)

fl.oz. (cm3)

51 20

cu.in. (cm3)

Oil quantity

45

Displacement

6.18"(157)

Design

2.38"(60.5)
2.60" (66)

HBP: F2

8261

or

8.74"(222)
6.93"(176)

D
C
E

Motor

Cut-in current LST

7.5/4.5

Resistance, main and start winding (77F)

31.5/15.0

Approvals

A B

4.13"(105)
4.21"(107)

2.8/4.5

30

75

4.13"(105)

watt

LRA (rated after 4 sec.UL984) LST

31.5
28

Motor size

EN 60335-2-34
0.75"(19)

6.50"(165)

0.63"(16)

6.30 (159)

Suction connector

location/I.D. in. (mm) C

0.252-0.259 (6.50.09)

Process connector

location/I.D. in. (mm) D

0.252-0.259 (6.50.09)

Discharge connector

location/I.D. in. (mm) E 0.189-0.193 (4.9+0.10/-0)

Compressors on a pallet

July 2001

146

6.42 (163)

pcs.

125

CG.42.X1.22

CK.40.B6.02

5.35"(136)

in. (mm) A

2.76"(70)

Height

4.00"(101.6)

Dimensions

0.14"(3.6)
6.70"(170)
7.01"(178)
8.03"(204)

August 2001

Capacity at LBP conditions (ASHRAE)


Evap. temp. in F
Evap. temp. in C
TL2.5G, 50Hz
TL2.5G, 60Hz

-30
-34.4

-20
-28.9

Btu/h

-13
-25
151
176

-10
-23.3
173
202

0
-17.8

10
-12.2

20
-6.7

30
-1.1

40
4.4

41
5
755
872

45
7.2

50
10

59
15

-28.9
-20

-25
-13
36
42

-23.3
-10
41
48

-17.8
0

-12.2
10

-6.7
20

-1.1
30

4.4
40

5
41
180
208

7.2
45

10
50

15
59

-20
-28.9

-13
-25
60
67

-10
-23.3
63
71

0
-17.8

10
-12.2

20
-6.7

30
-1.1

40
4.4

41
5
112
130

45
7.2

50
10

59
15

-20
-28.9

-13
-25
0.50
0.48

-10
-23.3
0.51
0.49

0
-17.8

10
-12.2

20
-6.7

30
-1.1

40
4.4

41
5
0.63
0.62

45
7.2

50
10

59
15

-13
-25
2.51
2.62

-10
-23.3
2.74
2.84

0
-17.8

10
-12.2

20
-6.7

30
-1.1

40
4.4

41
5
6.74
6.70

45
7.2

50
10

-25
-13
0.60
0.63

-23.3
-10
0.65
0.68

-17.8
0

-12.2
10

-6.7
20

-1.1
30

4.4
40

5
41
1.61
1.60

7.2
45

10
50

Capacity (EN 12900/CECOMAF)


Evap. temp. in C
Evap. temp. in F
TL2.5G, 50Hz
TL2.5G, 60Hz

-34.4
-30

watt

Power consumption
Evap. temp. in F
Evap. temp. in C
TL2.5G, 50Hz
TL2.5G, 60Hz

-30
-34.4

watt

Current consumption
Evap. temp. in F
Evap. temp. in C
TL2.5G, 50Hz
TL2.5G, 60Hz

-30
-34.4

EER at LBP conditions (ASHRAE)


Evap. temp. in F
Evap. temp. in C
TL2.5G, 50Hz
TL2.5G, 60Hz

-30
-34.4

-20
-28.9

Btu/Wh
59
15

COP (EN 12900/CECOMAF)


Evap. temp. in C
Evap. temp. in F
TL2.5G, 50Hz
TL2.5G, 60Hz

-34.4
-30

Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
50Hz: Static cooling, 220V
60 Hz: Static cooling, 220V
preliminary data

W/W

-28.9
-20

ASHRAE
130F (54,4C)
90F (32C)
90F (32C)

EN 12900/CECOMAF
55C (131F)
32C (90F)
55C (131F)
LST

15
59

HST
c

Accessories

b
8217-2

Devices
PTC starting device
1
/4 in. (6.3 mm) spades
3
/16 in. (4.8 mm) spades

Fig.

TL2.5G

a1
a2

117U6007

Cover

103N2010

Starting capacitor 60 F

117U5014

Cord relief

103N1010

August 2001

8219

in. (mm)
5
/8 (16)
5
/8 (16)
5
/8 (16)

a2

103N0011
103N0018

Starting relay

Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities

b
a1

118-1945
118-1948
118-1944

d
d
Main winding a1 Start winding
N

c
11

10

Winding protector

CG.42.X1.22

CK.40.B6.02

12

13
14

Main winding

Winding protector Start winding

July 2001

147

TL3G
Universal Compressor
R134a
220-240V 50Hz
Data Sheet (Replaces CD.42.J5.02)
General
TL3G

Code number

102G4350

Code number (UL-recognized)

102G4351

102G

TL3G
Application

R134a

Blue stripe
Approvals

Application

4350

Barcode on
white background

Application

LBP/HBP

Voltage range

DANFOSS COMPRESSORS

Yellow background

-30 to 15

V/Hz

LBP: 187 - 254 /50

TL3G
230V-60Hz
1PH

LBP: 198 - 254 /60


HBP: 198 - 254 /50
Motor type

RSIR/CSIR

Max. ambient temperature

Comp. cooling at ambient temp.

THERMALLY
PROTECTED

43

32C

Approval mark

LBP: S
S
O
F1

HBP: F2
38C

LBP: S
HBP: F2

43C

8284-4

Evaporating temperature range

8284

Compressor

F2

LBP: S

= Static cooling normally sufficient


= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

HBP: F2

Design

16

Displacement

cm3

Oil quantity

cm3

280

400

cm3

1500

kg

6.8

Free gas vol. in compressor


Weight without electrical equipment

35
70
100

Maximum refrigerant charge

3.13

9
170
178
186
204

Motor
95

3.5/4.9

Cut-in current LST/HST

8.0/4.9

EN 60335-2-34

Approvals (102G4351)

UL984/CSA-C22.2, EN 60335-2-34

30

24.3/15.5

Approvals (102G4350)

D
C

or

222
176

31.5
28

Resistance, main and start winding (25C)

C or
D

A B

105
107

watt

LRA (rated after 4 sec. UL984) LST/HST

105

Motor size

Dimensions

6.2 0.09

location/I.D. mm

6.2 0.09

Discharge connector

location/I.D. mm

5.0 +0.12/+0.20

May 2001

pcs.

125

CD.42.J6.02

CK.40.B6.02

45

location/I.D. mm

Process connector

8263

102

71

159

29

163

51 20

Suction connector

Compressors on a pallet

148

mm

157
60.5
66

Height

96
117

August 2001

Capacity (EN 12900/CECOMAF)


Evap. temp in C -30
TL3G, 50Hz
25.3
TL3G, 60Hz
29.5

watt

-25
40.9
47.4

-23.3
46.7
54.3

-20
59.1
68.9

-15
80.5
94.6

-10
106
125

-5
136

0
170

5
211

7.2
231

10
258

-25
50.4
58.4

-23.3
57.7
66.9

-20
72.9
85.0

-15
99.4
117

-10
131
155

-5
168

0
211

5
262

7.2
287

10
321

Capacity (ASHRAE)
Evap. temp in C -30
TL3G, 50Hz
31.2
TL3G, 60Hz
36.3

15
312

HST
c

watt
15
388

b
8219

a2

Power consumption
Evap. temp in C -30
TL3G, 50Hz
57.7
TL3G, 60Hz
60.0

watt
-25
65.8
69.7

-23.3
68.8
73.5

-20
75.0
81.0

-15
85.2
95.0

-10
96.2
111

-5
108

0
120

5
133

7.2
139

10
146

Current consumption
Evap. temp in C -30
TL3G, 50Hz
0.68
TL3G, 60Hz
0.60

A
-25
0.70
0.63

-23.3
0.70
0.64

-20
0.72
0.66

-15
0.74
0.70

-10
0.77
0.74

-5
0.80

0
0.84

5
0.88

7.2
0.89

10
0.92

COP (EN 12900/CECOMAF)


Evap. temp in C -30
TL3G, 50Hz
0.44
TL3G, 60Hz
0.49

11

10

15
0.97

12

13
14

W/W

-25
0.62
0.68

-23.3
0.68
0.74

-20
0.79
0.85

-15
0.95
0.99

-10
1.10
1.13

-5
1.26

0
1.42

5
1.59

7.2
1.67

10
1.77

-25
0.77
0.84

-23.3
0.84
0.91

-20
0.97
1.04

-15
1.17
1.23

-10
1.36
1.39

-5
1.56

0
1.76

5
1.97

7.2
2.07

10
2.20

COP (ASHRAE)
Evap. temp in C -30
TL3G, 50Hz
0.54
TL3G, 60Hz
0.61

15
159

15
1.96

Main winding

Winding protector Start winding

W/W

Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
50Hz: Static cooling, 220V
60Hz: Static cooling, 220V

EN 12900/CECOMAF
55C
32C
55C

15
2.44

LST
g

ASHRAE
55C
32C
32C

b
8217

a1
d
Main winding a1 Start winding
N

Accessories
Devices
PTC starting device

6.3 mm spades
4.8 mm spades

Fig.

TL3G

a1

103N0011
103N0018

Starting relay

a2

117U6009

Cover (102G4350)

103N2010

Cover (102G4351)

103N2011

Starting capacitor 60 F

117U5014

Cord relief

103N1010

Protection screen for PTC

103N0476

Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities

August 2001

Winding protector

118-1917
118-1918
118-1919

CD.42.J6.02

CK.40.B6.02

May 2001

149

TL4G
Universal Compressor
R134a
220-240V 50Hz
Data Sheet (Replaces CG.42.A1.02)
General
TL4G

102G

TL4G

Code number (small baseplate)

102G4452

Code number (small baseplate, UL-recognized)

102G4453

Code number (large baseplate, UL-recognized)

102G4454

Application

R134a

Blue stripe
Approvals

4452

Barcode on
white background

Application

DANFOSS COMPRESSORS

Yellow background

Application

8284-2

Compressor

LBP/HBP
R

Voltage range

-30 to 15

V/Hz

LBP: 187 - 254 /50

TL4G
230V-60Hz
1PH

LBP: 198 - 254 /60


HBP: 198 - 254 /50
Motor type

RSIR/CSIR

Max. ambient temperature

Comp. cooling at ambient temp.

THERMALLY
PROTECTED

43

32C

Approval mark

LBP: S

S
O
F1

HBP: F2
38C

LBP: S
HBP: F2

43C

8284-4

Evaporating temperature range

F2

= Static cooling normally sufficient


= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

LBP: S
HBP: F2
3.6

cm3

3.86

Oil quantity

cm3

280

Maximum refrigerant charge


Free gas vol. in compressor
Weight without electrical equipment

400

cm3

1690

kg

7.5

16

35
70
100

Displacement

9
19

170
178
186
204

Motor
watt
A

Cut-in current LST/HST

110

EN 60335-2-34
UL984/CSA-C22.2, EN 60335-2-34

Dimensions

102G4452/53
mm

173

169

A B
105

Approvals (102G4453, 102G4454)

31.5
28

18.2/15.1

Approvals (102G4452)

D
C

or

222
176

8.6/5.1

Resistance, main and start winding (25C)

Height

C or
D

4.3/5.1

105
107

LRA (rated after 4 sec. UL984) LST/HST

30

Motor size

101.6
136

Design

102G4454

D 6.2 0.09

6.5 0.09

location/I.D. mm

E 5.0 +0.12/+0.20

5.0 +0.12/+0.20

pcs.

125
102

May 2001

150

71

location/I.D. mm

Discharge connector

29

Process connector

Compressors on a pallet

6.5 0.09

51 20

C 6.2 0.09

45

location/I.D. mm

157
60.5
66

8428

Suction connector

CG.42.A2.02

CK.40.B6.02

96
117

August 2001

Capacity (EN 12900/CECOMAF)


Evap. temp in C -30
TL4G, 50Hz
40.8
TL4G, 60Hz
48.4

watt

-25
58.3
69.5

-23.3
65.3
77.8

-20
80.3
95.7

-15
107
127

-10
140
166

-5
180

0
226

5
280

7.2
306

10
342

-25
71.9
85.8

-23.3
80.5
96.0

-20
99.2
118

-15
133
157

-10
173
205

-5
222

0
280

5
347

7.2
380

10
425

Capacity (ASHRAE)
Evap. temp in C -30
TL4G, 50Hz
50.3
TL4G, 60Hz
59.6

15
413

HST
c

watt
15
515

b
8219

a2

Power consumption
Evap. temp in C -30
TL4G, 50Hz
71.7
TL4G, 60Hz
74.2

watt
-25
82.7
86.8

-23.3
86.6
91.6

-20
94.2
101

-15
106
117

-10
118
135

-5
130

0
142

5
154

7.2
159

10
165

Current consumption
Evap. temp in C -30
TL4G, 50Hz
0.82
TL4G, 60Hz
0.70

A
-25
0.84
0.74

-23.3
0.85
0.76

-20
0.87
0.79

-15
0.90
0.84

-10
0.93
0.90

-5
0.96

0
1.00

5
1.04

7.2
1.05

10
1.08

COP (EN 12900/CECOMAF)


Evap. temp in C -30
TL4G, 50Hz
0.57
TL4G, 60Hz
0.65

11

10

15
1.12

12

13
14

W/W

-25
0.70
0.80

-23.3
0.75
0.85

-20
0.85
0.94

-15
1.01
1.09

-10
1.19
1.23

-5
1.38

0
1.59

5
1.82

7.2
1.93

10
2.07

-25
0.87
0.99

-23.3
0.93
1.05

-20
1.05
1.17

-15
1.25
1.34

-10
1.47
1.52

-5
1.71

0
1.97

5
2.26

7.2
2.39

10
2.57

COP (ASHRAE)
Evap. temp in C -30
TL4G, 50Hz
0.70
TL4G, 60Hz
0.80

15
176

15
2.34

Main winding

Winding protector Start winding

W/W

Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
50Hz: Static cooling, 220V
60Hz: Static cooling, 220V

EN 12900/CECOMAF
55C
32C
55C

15
2.92

LST
g

ASHRAE
55C
32C
32C

b
8217

a1
d
Main winding a1 Start winding
N

Accessories
Devices

Fig.

TL4G

a1

103N0011
103N0018

Starting relay

a2

117U6004

Cover (102G4452)

103N2010

PTC starting device

6.3 mm spades
4.8 mm spades

Cover (102G4453, 102G4454)

103N2011

Starting capacitor 60 F

117U5014

Cord relief

103N1010

Protection screen for PTC

103N0476

Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities

August 2001

Winding protector

118-1917
118-1918
118-1919

CG.42.A2.02

CK.40.B6.02

May 2001

151

TL5G
Universal Compressor
R134a
220-240V 50Hz
Data Sheet (Replaces CG.42.C1.02)
General
TL5G

Code number

102G4550

102G

TL5G
Application

R134a

Blue stripe
Approvals

Application
Application
Evaporating temperature range
Voltage range

C
V/Hz

LBP/HBP

Barcode on
white background

-30 to 15

Yellow background

4550

8284-3

Compressor

DANFOSS COMPRESSORS

LBP: 187 - 254 /50


LBP: 198 - 254 /60
HBP: 198 - 254 /50

Motor type

RSIR/CSIR

Max. ambient temperature

Comp. cooling at ambient temp.

43

32C

LBP: S
HBP: F2

38C

S
O
F1

LBP: S
HBP: F2

43C

LBP: S
F2

HBP: F2

= Static cooling normally sufficient


= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

Design
cm3

5.08

Oil quantity

cm3

280

Maximum refrigerant charge


Free gas vol. in compressor
Weight without electrical equipment

400

cm3

1690

kg

7.5

16

35
70
100

Displacement

Motor
watt

170
178
186
204

140

LRA (rated after 4 sec. UL984) LST/HST

5.4/5.7

Cut-in current LST/HST

9.7/5.7

Resistance, main and start winding (25C)

C or
D

14.5/14.8
30

EN 60335-2-34

31.5
28

105

A
B

169

Suction connector

location/I.D. mm

6.2 0.09

Process connector

location/I.D. mm

6.2 0.09

Discharge connector

location/I.D. mm

5.0 +0.12/+0.20

pcs.

125

8263

45

Compressors on a pallet

173

102

May 2001

152

CG.42.C2.02

CK.40.B6.02

51 20

mm

157
60.5
66

Height

105
107

A B

Dimensions

71

Approvals

D
C

or

222
176

29

Motor size

96
117

August 2001

Capacity (EN 12900/CECOMAF)


Evap. temp in C -30
TL5G, 50Hz
55.6
TL5G, 60Hz
64.7

watt

-25
79.0
91.5

-23.3
87.9
102

-20
107
123

-15
139
162

-10
178
207

-5
224

0
278

5
341

7.2
372

10
414

-25
97.5
113

-23.3
108
125

-20
132
152

-15
172
200

-10
220
256

-5
277

0
345

5
423

7.2
461

10
514

Capacity (ASHRAE)
Evap. temp in C -30
TL5G, 50Hz
68.6
TL5G, 60Hz
79.8

15
497

HST
c

watt
15
619

b
8219

a2

Power consumption

watt

Evap. temp in C -30


-25 -23.3
TL5G, 50Hz
84.8 100
105
TL5G, 60Hz
88.7 105.7 112.1

-20
116
125

-15
132
147

-10
149
170

-5
167

0
186

5
205

7.2
213

10
224

Current consumption
Evap. temp in C -30
TL5G, 50Hz
0.95
TL5G, 60Hz
0.83

A
-25
0.98
0.88

-23.3
0.99
0.90

-20
1.01
0.94

-15
1.05
1.01

-10
1.09
1.08

-5
1.15

0
1.21

5
1.28

7.2
1.32

10
1.36

COP (EN 12900/CECOMAF)


Evap. temp in C -30
TL5G, 50Hz
0.66
TL5G, 60Hz
0.73

11

10

15
1.45

12

13
14

W/W

-25
0.79
0.87

-23.3
0.83
0.91

-20
0.92
0.99

-15
1.05
1.10

-10
1.19
1.22

-5
1.34

0
1.50

5
1.67

7.2
1.74

10
1.84

-25
0.97
1.07

-23.3
1.03
1.12

-20
1.14
1.22

-15
1.30
1.36

-10
1.47
1.51

-5
1.66

0
1.86

5
2.07

7.2
2.16

10
2.29

COP (ASHRAE)
Evap. temp in C -30
TL5G, 50Hz
0.81
TL5G, 60Hz
0.90

15
245

15
2.03

Main winding

Winding protector Start winding

W/W

Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
50Hz: Static cooling, 220V
60Hz: Static cooling, 220V

EN 12900/CECOMAF
55C
32C
55C

15
2.53

LST
g

ASHRAE
55C
32C
32C

b
8217

a1
d
Main winding a1 Start winding
N

Accessories
Devices

Fig.

TL5G

a1

103N0011
103N0018

Starting relay

a2

117U6000

Cover

103N2010

Starting capacitor 60 F

117U5014

Cord relief

103N1010

Protection screen for PTC

103N0476

PTC starting device

6.3 mm spades
4.8 mm spades

Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities

August 2001

Winding protector

118-1917
118-1918
118-1919

CG.42.C2.02

CK.40.B6.02

May 2001

153

FR6G
Universal Compressor
R134a
220-240V 50Hz
Data Sheet (Replaces CD.43.I5.02)
General
FR6G

Code number

103G6660

103G

FR6G
Application

R134a

Blue stripe
Approvals

Application
Application
Evaporating temperature range
Voltage range

C
V/Hz

LBP/HBP

Barcode on
white background

-30 to 10

Yellow background

6660

8285-3

Compressor

DANFOSS COMPRESSORS

LBP: 187 - 254 /50


LBP: 198 - 254 /60
HBP: 198 - 254 /50

Motor type

S
O
F1

RSIR/CSIR

Max. ambient temperature

Comp. cooling at ambient temp.

43

32C

LBP: S

F2

= Static cooling normally sufficient


= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

HBP: F2
38C

LBP: S
HBP: F2

43C

LBP: S
HBP: F2

Design

204
178

16

Displacement

cm3

Oil quantity

cm3

450

900

cm3

1350

kg

10.6

Free gas vol. in compressor


Weight without electrical equipment

35
127
150

101.6
70
60.5

Maximum refrigerant charge

9.7

127
165
170
186
200

Motor
watt

150

5.8/7.5

10.5/7.5

Resistance, main and start winding (25C)

12.6/12.4
A B

127

EN 60335-2-34

25

Approvals

30

Cut-in current LST/HST

C
E

102
130

LRA (rated after 4 sec. UL984) LST/HST

30

Motor size

19

6.23

Dimensions

Suction connector

location/I.D. mm

8.2 0.09

Process connector

location/I.D. mm

6.2 0.09

Discharge connector

location/I.D. mm

6.2 0.09

Compressors on a pallet

pcs.

243

154

24

80
122.5

May 2001

8253

32
55

191

40

196

40

55

mm

156

Height

CD.43.I6.02

CK.40.B6.02

124.5
127.5

August 2001

Capacity (EN 12900/CECOMAF)


Evap. temp in C -30
FR6G, 50Hz
47.7
FR6G, 60Hz
50.6

watt

-25
83.3
92.5

-23.3
96.5
108

-20
124
141

-15
171
199

-10
226
266

-5
290

0
365

5
452

7.2
494

-25
103
114

-23.3
119
134

-20
153
175

-15
211
246

-10
279
329

-5
359

0
452

5
561

7.2
614

Capacity (ASHRAE)
Evap. temp in C -30
FR6G, 50Hz
58.9
FR6G, 60Hz
62.4

10
687

b
8219

a2

watt
-25
109
119

-23.3
115
127

-20
129
144

-15
149
170

-10
172
197

-5
194

0
218

5
241

7.2
251

10
264

-25
0.85
0.77

-23.3
0.87
0.80

-20
0.91
0.86

-15
0.98
0.97

-10
1.06
1.09

-5
1.14

0
1.23

5
1.33

7.2
1.37

10
1.43

Current consumption
Evap. temp in C -30
FR6G, 50Hz
0.79
FR6G, 60Hz
0.69

HST

watt

Power consumption
Evap. temp in C -30
FR6G, 50Hz
91.3
FR6G, 60Hz
94.8

10
552

c
11

10

12

13
14

COP (EN 12900/CECOMAF)


Evap. temp in C -30
FR6G, 50Hz
0.52
FR6G, 60Hz
0.53

W/W

-25
0.76
0.78

-23.3
0.84
0.85

-20
0.96
0.98

-15
1.14
1.17

-10
1.32
1.35

-5
1.49

0
1.68

5
1.88

7.2
1.97

-25
0.94
0.96

-23.3
1.03
1.05

-20
1.19
1.21

-15
1.41
1.44

-10
1.63
1.67

-5
1.85

0
2.08

5
2.33

7.2
2.44

COP (ASHRAE)
Evap. temp in C -30
FR6G, 50Hz
0.64
FR6G, 60Hz
0.66

10
2.09

Main winding

Winding protector Start winding

W/W

Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
50Hz: Fan cooling F2, 220V
60Hz: Fan cooling F2, 220V

EN 12900/CECOMAF
55C
32C
55C

10
2.60

LST
g

ASHRAE
55C
32C
32C

b
8217

a1
d
Main winding a1 Start winding

Accessories
Devices

Fig.

FR6G

a1

103N0011
103N0018

Starting relay

a2

117U6000
103N2010

PTC starting device

6.3 mm spades
4.8 mm spades

Cover

Starting capacitor 80 F

117U5015

Cord relief

103N1010

Protection screen for PTC

103N0476

Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities

August 2001

Winding protector

118-1917
118-1918
118-1919

CD.43.I6.02

CK.40.B6.02

May 2001

155

FR7.5G
Universal Compressor
R134a
220-240V 50Hz
Data Sheet (Replaces CG.43.F1.02)
General
FR7.5G

Code number

103G6680

Code number compressor with oil cooler

103G6690

103G

FR7.5G
Application

R134a

Blue stripe
Approvals

Application

6680

Barcode on
white background

Application

LBP/HBP

Evaporating temperature range


Voltage range

LBP: 187 - 254 /50


LBP: 198 - 254 /60

S
O
F1

HBP: 198 - 254 /50


Motor type

RSIR/CSIR
C

Comp. cooling at ambient temp.

DANFOSS COMPRESSORS

Yellow background

-30 to 10

V/Hz

Max. ambient temperature

8285

Compressor

43

32C

F2

= Static cooling normally sufficient


= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

LBP: S
HBP: F2

38C

LBP: S
HBP: F2

43C

LBP: O/F1
HBP: F2
204
178

16

Design
Displacement

cm3

Oil quantity

cm3

450

900

cm3

1350

kg

10.6

watt

175

Free gas vol. in compressor


Weight without electrical equipment

6.93
35
127
150

101.6
70
60.5

Maximum refrigerant charge

9.7

127
165
170
186
200

Motor

11.4/8.1

Resistance, main and start winding (25C)

10.7/13.0

A B

EN 60335-2-34, CCIB

34

127

Approvals

102
130

6.8/8.1

25

Cut-in current LST/HST

C
E
30

LRA (rated after 4 sec. UL984) LST/HST

30

Motor size

19

Dimensions

8.2 0.09

6.2 0.09

Discharge connector

location/I.D. mm

6.2 0.09

Oil cooler

location/I.D. mm

6.2 0.09

May 2001

pcs.

80

CG.43.F2.02

CK.40.B6.02

40

location/I.D. mm

F
8266

122.5

24

32
55

location/I.D. mm

Process connector

243
264

40

191

40

196

156

Suction connector

Compressors on a pallet

156

mm

55

Height

124.5
127.5

August 2001

Capacity (EN 12900/CECOMAF)


Evap. temp in C -30
FR7.5G, 50Hz
61.7
FR7.5G, 60Hz
66.5

watt

-25
99.0
112

-23.3
113
130

-20
142
166

-15
193
228

-10
254
300

-5
325

0
408

5
505

7.2
553

-25
122
139

-23.3
139
160

-20
176
204

-15
239
281

-10
314
371

-5
402

0
506

5
627

7.2
687

Capacity (ASHRAE)
Evap. temp in C -30
FR7.5G, 50Hz
76.1
FR7.5G, 60Hz
82.0

-30
108
110

10
768

b
8219

a2

watt
-25
126
138

-23.3
133
148

-20
147
167

-15
170
198

-10
194
229

-5
220

0
246

5
272

7.2
284

10
298

-25 -23.3
0.90 0.93
0.81 0.85

-20
0.99
0.94

-15
1.09
1.07

-10
1.19
1.19

-5
1.30

0
1.41

5
1.52

7.2
1.58

10
1.64

Current consumption
Evap. temp in C -30
FR7.5G, 50Hz
0.81
FR7.5G, 60Hz
0.67

HST

watt

Power consumption
Evap. temp in C
FR7.5G, 50Hz
FR7.5G, 60Hz

10
618

c
11

10

12

13
14

COP (EN 12900/CECOMAF)


Evap. temp in C -30
FR7.5G, 50Hz
0.57
FR7.5G, 60Hz
0.60

W/W

-25 -23.3
0.79 0.85
0.81 0.88

-20
0.97
0.99

-15
1.14
1.15

-10
1.30
1.31

-5
1.48

0
1.66

5
1.86

7.2
1.95

-25
0.97
1.00

-20
1.20
1.22

-15
1.41
1.42

-10
1.61
1.62

-5
1.83

0
2.05

5
2.30

7.2
2.42

COP (ASHRAE)
Evap. temp in C -30
FR7.5G, 50Hz
0.71
FR7.5G, 60Hz
0.74

10
2.07

Main winding

Winding protector Start winding

W/W

Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
50Hz: Fan cooling F2, 220V
60Hz: Fan cooling F2, 220V

-23.3
1.05
1.08

EN 12900/CECOMAF
55C
32C
55C

10
2.58

LST
g

ASHRAE
55C
32C
32C

b
8217

a1
d
Main winding a1 Start winding

Accessories
Devices

Fig.

FR7.5G

a1

103N0011
103N0018

Starting relay

a2

117U6001
103N2010

PTC starting device

6.3 mm spades
4.8 mm spades

Cover

Starting capacitor 80 F

117U5015

Cord relief

103N1010

Protection screen for PTC

103N0476

Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities

August 2001

Winding protector

118-1917
118-1918
118-1919

CG.43.F2.02

CK.40.B6.02

May 2001

157

FR8.5G
Universal Compressor
R134a
220-240V 50Hz
Data Sheet (CG.43.H1.02)
General
FR8.5G

Code number

103G6780

Code number compressor with oil cooler

103G6790

103G

FR8.5G
Application

R134a

Blue stripe
Approvals

Application

6780

Barcode on
white background

Application

LBP/HBP

Evaporating temperature range


Voltage range

LBP: 187 - 254 /50


LBP: 198 - 254 /60

S
O
F1

HBP: 198 - 254 /50


Motor type

RSIR/CSIR
C

Comp. cooling at ambient temp.

DANFOSS COMPRESSORS

Yellow background

-30 to 10

V/Hz

Max. ambient temperature

8285-4

Compressor

43

32C

LBP: S

38C

LBP: O/F1

43C

LBP: O/F1

F2

= Static cooling normally sufficient


= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

HBP: F2
HBP: F2
HBP: F2
204
178

16

Design
Displacement

cm3

Oil quantity

cm3

450

900

cm3

1350

kg

10.6

Free gas vol. in compressor


Weight without electrical equipment

7.95
35
127
150

101.6
70
60.5

Maximum refrigerant charge

9.7

127
165
170
186
200

Motor
215

Cut-in current LST/HST

12.8/8.2

Resistance, main and start winding (25C)

8.9/12.0

C
E

A B

EN 60335-2-34, CCIB

34

127

Approvals

25

8.1/8.2

30

102
130

watt

LRA (rated after 4 sec. UL984) LST/HST

30

Motor size

19

Dimensions

8.2 0.09

6.2 0.09

Discharge connector

location/I.D. mm

6.2 0.09

Oil cooler

location/I.D. mm

6.2 0.09

May 2001

pcs.

80

CG.43.H2.02

CK.40.B6.02

40

location/I.D. mm

F
8266

122.5

24

32
55

location/I.D. mm

Process connector

243
264

40

191

40

196

156

Suction connector

Compressors on a pallet

158

mm

55

Height

124.5
127.5

August 2001

Capacity (EN 12900/CECOMAF)


Evap. temp in C -30
FR8.5G, 50Hz
84.9
FR8.5G, 60Hz
92.3

watt

-25
123
138

-23.3
138
156

-20
171
195

-15
228
263

-10
298
345

-5
381

0
478

5
592

7.2
647

-25
152
171

-23.3
171
193

-20
211
241

-15
282
325

-10
368
426

-5
471

0
592

5
734

7.2
803

Capacity (ASHRAE)
Evap. temp in C
FR8.5G, 50Hz
FR8.5G, 60Hz

-30
105
114

-30
127
134

10
898

b
8219

a2

watt
-25
151
164

-23.3
159
174

-20
176
197

-15
203
233

-10
231
273

-5
261

0
291

5
321

7.2
335

10
352

-25
1.22
1.12

-23.3
1.25
1.16

-20
1.30
1.24

-15
1.38
1.37

-10
1.47
1.53

-5
1.56

0
1.67

5
1.78

7.2
1.83

10
1.90

Current consumption
Evap. temp in C -30
FR8.5G, 50Hz
1.16
FR8.5G, 60Hz
1.02

HST

watt

Power consumption
Evap. temp in C
FR8.5G, 50Hz
FR8.5G, 60Hz

10
722

c
11

10

12

13
14

COP (EN 12900/CECOMAF)


Evap. temp in C -30
FR8.5G, 50Hz
0.67
FR8.5G, 60Hz
0.69

-25
0.82
0.85

W/W

-23.3
0.87
0.90

-20
0.97
0.99

-15
1.12
1.13

-10
1.29
1.26

-5
1.46

0
1.65

5
1.84

7.2
1.93

-25 -23.3
1.01 1.07
1.04 1.11

-20
1.19
1.22

-15
1.39
1.39

-10
1.59
1.56

-5
1.81

0
2.04

5
2.29

7.2
2.40

COP (ASHRAE)
Evap. temp in C -30
FR8.5G, 50Hz
0.83
FR8.5G, 60Hz
0.85

10
2.05

Main winding

Winding protector Start winding

W/W

Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
50Hz: Fan cooling F2, 220V
60Hz: Fan cooling F2, 220V

EN 12900/CECOMAF
55C
32C
55C

10
2.55

LST
g

ASHRAE
55C
32C
32C

b
8217

a1
d
Main winding a1 Start winding

Accessories
Devices

Fig.

FR8.5G

a1

103N0011
103N0018

Starting relay

a2

117U6015
103N2010

PTC starting device

6.3 mm spades
4.8 mm spades

Cover

Starting capacitor 80 F

117U5015

Cord relief

103N1010

Protection screen for PTC

103N0476

Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities

August 2001

Winding protector

118-1917
118-1918
118-1919

CG.43.H2.02

CK.40.B6.02

May 2001

159

FR10G
Universal Compressor
R134a
220-240V 50Hz
Data Sheet (Replaces CD.43.O5.02)
General
FR10G

Code number

103G6880

Code number compressor with oil cooler

103G6890

103G

FR10G
Application

R134a

Blue stripe
Approvals

Application

6880

Barcode on
white background

Application

LBP/HBP

Evaporating temperature range


Voltage range

LBP: 187 - 254 /50


LBP: 198 - 254 /60

S
O
F1

HBP: 198 - 254 /50


Motor type

RSIR/CSIR
C

Comp. cooling at ambient temp.

DANFOSS COMPRESSORS

Yellow background

-30 to 10

V/Hz

Max. ambient temperature

8285-2

Compressor

43

32C

F2

= Static cooling normally sufficient


= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

LBP: S
HBP: F2

38C

LBP: O/F1

43C

LBP: O/F1

HBP: F2
HBP: F2
204
178

16

Design
Displacement

cm3

Oil quantity

cm3

450

900

cm3

1350

kg

10.6

watt

275

Motor
Motor size

10.3/10.0

15.0/10.0

Resistance, main and start winding (25C)

7.3/12.0

35
127
150

C
E

A B

EN 60335-2-34, CCIB

34

127

Approvals

25

Cut-in current LST/HST

127
165
170
186
200

30

LRA (rated after 4 sec. UL984) LST/HST

9.7

102
130

Weight without electrical equipment

30

Free gas vol. in compressor

9.05
101.6
70
60.5

Maximum refrigerant charge

19

Dimensions

8.2 0.09

6.2 0.09

Discharge connector

location/I.D. mm

6.2 0.09

Oil cooler

location/I.D. mm

6.2 0.09

May 2001

pcs.

80

CD.43.O6.02

CK.40.B6.02

40

location/I.D. mm

F
8266

122.5

24

32
55

location/I.D. mm

Process connector

243
264

40

191

40

196

156

Suction connector

Compressors on a pallet

160

mm

55

Height

124.5
127.5

August 2001

Capacity (EN 12900/CECOMAF)


Evap. temp in C -30
FR10G, 50Hz
91.9
FR10G, 60Hz
98.8

watt

-25
136
153

-23.3
152
173

-20
188
217

-15
250
292

-10
324
381

-5
412

0
516

5
638

7.2
697

-25
167
188

-23.3
188
214

-20
232
267

-15
308
361

-10
400
471

-5
510

0
639

5
791

7.2
866

Capacity (ASHRAE)
Evap. temp in C
FR10G, 50Hz
FR10G, 60Hz

-30
113
122

-30
155
163

10
968

b
8219

a2

watt
-25
179
194

-23.3
188
206

-20
205
230

-15
234
270

-10
265
314

-5
296

0
329

5
362

7.2
376

10
394

-25
1.58
1.44

-23.3
1.61
1.48

-20
1.66
1.57

-15
1.75
1.73

-10
1.84
1.90

-5
1.94

0
2.05

5
2.16

7.2
2.21

10
2.28

Current consumption
Evap. temp in C -30
FR10G, 50Hz
1.51
FR10G, 60Hz
1.32

HST

watt

Power consumption
Evap. temp in C
FR10G, 50Hz
FR10G, 60Hz

10
779

c
11

10

12

13
14

COP (EN 12900/CECOMAF)


Evap. temp in C -30
FR10G, 50Hz
0.59
FR10G, 60Hz
0.61

W/W

-25
0.76
0.79

-23.3
0.81
0.84

-20
0.91
0.94

-15
1.07
1.08

-10
1.22
1.21

-5
1.39

0
1.57

5
1.76

7.2
1.85

-25
0.93
0.97

-23.3
1.00
1.04

-20
1.13
1.16

-15
1.32
1.34

-10
1.51
1.50

-5
1.72

0
1.94

5
2.19

7.2
2.30

COP (ASHRAE)
Evap. temp in C -30
FR10G, 50Hz
0.73
FR10G, 60Hz
0.75

10
1.98

Main winding

Winding protector Start winding

W/W

Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
50Hz: Fan cooling F2, 220V
60Hz: Fan cooling F2, 220V

EN 12900/CECOMAF
55C
32C
55C

10
2.46

LST
g

ASHRAE
55C
32C
32C

b
8217

a1
d
Main winding a1 Start winding

Accessories
Devices

Fig.

FR10G

a1

103N0011
103N0018

Starting relay

a2

117U6010
103N2010

PTC starting device

6.3 mm spades
4.8 mm spades

Cover

Starting capacitor 80 F

117U5015

Cord relief

103N1010

Protection screen for PTC

103N0476

Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities

August 2001

Winding protector

118-1917
118-1918
118-1919

CD.43.O6.02

CK.40.B6.02

May 2001

161

FR11G
Universal Compressor
R134a
220-240V 50Hz
Data Sheet (Replaces CG.43.E1.02)
General
FR11G

Code number

103G6980

103G

FR11G
Application

R134a

Blue stripe
Approvals

Application
Application
Evaporating temperature range
Voltage range

C
V/Hz

LBP/HBP

Barcode on
white background

-30 to 5

Yellow background

6880

8285-5

Compressor

DANFOSS COMPRESSORS

LBP: 187 - 254 /50


HBP: 198 - 254 /50

Motor type

RSIR/CSIR

Max. ambient temperature

Comp. cooling at ambient temp.

S
O
F1

43

32C

LBP: F2
HBP: F2

38C

F2

= Static cooling normally sufficient


= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

LBP: F2
HBP: F2

43C

LBP: F2
HBP: F2

Design
cm3

11.15

450

cm

Maximum refrigerant charge


Free gas vol. in compressor
Weight without electrical equipment

900

cm3

1350

kg

10.6

watt

275

Motor

9.7

Motor size
LRA (rated after 4 sec. UL984) LST/HST

10.3/10.0

Cut-in current LST/HST

15.0/10.0

Resistance, main and start winding (25C)

19

35
127
150

Oil quantity

204
178

16

101.6
70
60.5

Displacement

127
165
170
186
200

C
E

7.3/12.0
30

EN 60335-2-34, CCIB

30

Approvals

25

location/I.D. mm

8.2 0.09

Process connector

location/I.D. mm

6.2 0.09

Discharge connector

location/I.D. mm

6.2 0.09

pcs.

80

55

Compressors on a pallet

243

122.5

May 2001

162

CG.43.E2.02

CK.40.B6.02

8253

24

40

191

Suction connector

32
55

196

40

127

mm

156

Height

102
130

A B

Dimensions

124.5
127.5

August 2001

Capacity (EN 12900/CECOMAF)


Comp.\C
FR11G

-30
115

-25
170

-23.3
191

watt
-20
233

-15
307

-10
395

-5
501

0
628

5
780

HST
c

Capacity (ASHRAE)
Comp.\C
FR11G

-30
141

-25
209

watt
-23.3
235

-20
287

-15
378

-10
487

-5
619

0
777

5
966
b

Power consumption
Comp.\C
FR11G

-30
165

-25
202

watt
-23.3
215

-20
240

-15
278

-10
317

-5
357

0
400

8219

5
445

a2
d

Current consumption
Comp.\C
FR11G

-30
1.52

-25
1.59

A
-23.3
1.63

-20
1.69

-15
1.81

-10
1.95

-5
2.10

0
2.26

5
2.42

c
11

10

COP (EN 12900/CECOMAF)


Comp.\C
FR11G

-30
0.70

W/W

-25
0.84

-23.3
0.89

-20
0.97

-15
1.11

-10
1.25

-5
1.40

0
1.57

-25
1.04

-23.3
1.09

-20
1.20

-15
1.36

-10
1.54

-5
1.73

0
1.94

COP (ASHRAE)
Comp.\C
FR11G

-30
0.86

5
1.75

12

13
14

W/W

Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Fan cooling F2, 220V 50Hz

EN 12900/CECOMAF
55C
32C
55C

5
2.17

ASHRAE
55C
32C
32C

Main winding

Winding protector Start winding

LST
g

b
8217

a1

Accessories
Devices

Fig.

FR11G

a1

103N0011
103N0018

Starting relay

a2

117U6010
103N2010

PTC starting device

6.3 mm spades
4.8 mm spades

d
Main winding a1 Start winding
N

Cover

Starting capacitor 80 F

117U5015

Cord relief

103N1010

Protection screen for PTC

103N0476

Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities

August 2001

118-1917
118-1918
118-1919

CG.43.E2.02

CK.40.B6.02

Winding protector

May 2001

163

SC10G
Universal Compressor
R134a
220-240V 50Hz
Data Sheet (Replaces CD.44.C4.02)
General
SC10G

Code number

104G8000

Application
Application

LBP/HBP

Evaporating temperature range


Voltage range

-35 to 15

V/Hz

104G

SC10G
Application

R134a

Blue stripe
Approvals

8000

Barcode on
white background

DANFOSS COMPRESSORS

Yellow background

8286

Compressor

LBP: 187 - 254 /50


LBP: 198 - 254 /60
HBP: 198 - 254 /50

Motor type

S
O
F1

RSIR/CSIR

Max. ambient temperature

Comp. cooling at ambient temp.

43

32C

LBP: F1

F2

HBP: F2
38C

= Static cooling normally sufficient


= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

LBP: F1
HBP: F2

43C

LBP: F1
HBP: F2

Design
600 (550 on comp. with oil cooler)

1300

cm3

1510

kg

12.1

watt

250

cm

Maximum refrigerant charge


Free gas vol. in compressor
Weight without electrical equipment

Motor
Motor size
LRA (rated after 4 sec. UL984) LST/HST

10.2/11.1

Cut-in current LST/HST

14.6/11.1

Resistance, main and start winding (25C)

8.5/14.1

Approvals

19
9.7

127
101.6
35

Oil quantity

204
178
170

16

10.29

70
150

cm3

Displacement

127
165
186
218

C
E

EN 60335-2-34
B A

B1

Dimensions

B2

mm

199
3

Height

location/I.D. mm

8.2 0.09

Process connector

location/I.D. mm

6.2 0.09

Discharge connector

location/I.D. mm

6.2 0.09

May 2001

pcs.

80

CD.44.C5.02

CK.40.B6.02

63

90

37

37

107

107
115

55
63

B2

255

55

173

151

193

B1

Suction connector

Compressors on a pallet

164

8258

August 2001

Capacity (EN 12900/CECOMAF)


Comp.\C
SC10G

-35
23

-30
60

-25
113

-23.3
135

watt
-20
183

-15
268

-10
369

-5
486

0
618

5
764

7.2
833

10
925

15
1100

HST
c

Capacity (ASHRAE)
Comp.\C
SC10G

-35
29

-30
74

watt
-25
139

-23.3
166

-20
225

-15
331

-10
456

-5
600

0
764

5
946

7.2
10
15
1032 1147 1367

b
8222

a2

Power consumption
Comp.\C
SC10G

-35
93

-30
139

watt
-25 -23.3
181 195

-20
220

-15
256

-10
290

-5
322

0
353

5
383

7.2
396

10
412

15
441

Current consumption
Comp.\C
SC10G

-35
1.29

-30
1.34

A
-25 -23.3 -20
1.41 1.44 1.50

-15
1.61

-10
1.72

-5
1.85

0
1.98

5
2.12

7.2
2.18

10
2.26

COP (EN 12900/CECOMAF)


Comp.\C
SC10G

-35
0.25

-35
0.31

15
2.40

12

13
14

W/W

-30
0.43

-25 -23.3 -20


0.63 0.69 0.83

-15
1.05

-10
1.27

-5
1.51

0
1.75

5
2.00

7.2
2.11

10
2.25

-30
0.53

-25 -23.3 -20


0.77 0.85 1.02

-15
1.29

-10
1.57

-5
1.86

0
2.16

5
2.47

7.2
2.61

10
2.78

COP (ASHRAE)
Comp.\C
SC10G

11

10

15
2.49

Start winding
Main winding
Winding protector

W/W

Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Fan cooling, 220V 50Hz

EN 12900/CECOMAF
55C
32C
55C

ASHRAE
55C
32C
32C

15
3.10

LST

b
8221

a1
d
Main winding

a1

Start winding

Accessories
Devices
PTC starting device

6.3 mm spades

Fig.

SC10G

a1

103N0002

Starting relay

a2

117U6002

Cover

103N2009

Starting capacitor 80 F

117U5017

Cord relief

103N1004

Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities

August 2001

Winding protector

118-1917
118-1918
118-1919

CD.44.C5.02

CK.40.B6.02

May 2001

165

SC12G
Universal Compressor
R134a
220-240V 50Hz
Data Sheet (Replaces CD.44.P1.02)
General
SC12G

Code number

104G8240

Code number

104G8243

Code number compressor with oil cooler

104G8250

104G

SC12G
Application

R134a

Blue stripe
Approvals

8240

Barcode on
white background

Application
Application
Evaporating temperature range
Voltage range

-35 to 15

V/Hz

LBP: 187 - 254 /50


LBP: 198 - 254 /60

S
O
F1

HBP: 198 - 254 /50


Motor type

= Static cooling normally sufficient


= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

RSIR/CSIR

Max. ambient temperature

Comp. cooling at ambient temp.

DANFOSS COMPRESSORS

Yellow background

LBP/HBP

8286-6

Compressor

43

32C

F2

LBP: O/F1
HBP: F2

38C

LBP: O/F1

43C

LBP: O/F1

HBP: F2
HBP: F2

204
178
170

16

Design
Displacement

cm3

Oil quantity

cm3 600 (550 on comp. with oil cooler)

1510

kg

12.6

Motor
watt
A

12.4/12.6

Cut-in current LST/HST

17.2/12.6

Resistance, main and start winding (25C)

EN 60335-2-34

209

203

B1

183

100

location/I.D. mm

C 8.2 0.09

8.2 0.09

10.2 0.09

Process connector

location/I.D. mm

D 6.2 0.09

6.2 0.09

6.5 0.09

Discharge connector

location/I.D. mm

E 6.2 0.09

6.2 0.09

6.5 0.09

Oil cooler

location/I.D. mm

F 6.2 0.09

May 2001

pcs.

B2

255

Suction connector

Compressors on a pallet

15

63

B2

30

104G8240 104G8243

53

104G8250

B A

B1

Dimensions
mm

6.7/11.8

Approvals

166

315

LRA (rated after 4 sec. UL984) LST/HST

Height

127
165
186
218

37

37

107

80
CD.44.P2.02

CK.40.B6.02

107
115

55
63

Motor size

70
150

1300

55

Weight without electrical equipment

g
cm3

127
101.6
35

Free gas vol. in compressor

12.87

151

Maximum refrigerant charge

19
9.7

8264

August 2001

Capacity (EN 12900/CECOMAF)


Comp.\C
SC12G

-35
78

-30
115

-25
175

-23.3
200

watt
-20
257

-15
360

-10
484

-5
625

0
785

5
960

7.2
10
15
1042 1150 1354

HST
c

Capacity (ASHRAE)
Comp.\C
SC12G

-35
97

-30
141

watt
-25
215

-23.3
247

-20
317

-15
444

-10
596

-5
772

0
960

5
7.2
10
15
1188 1291 1426 1682

b
8222

a2

Power consumption
Comp.\C
SC12G

-35
147

-30
186

watt
-25
227

-23.3
241

-20
269

-15
313

-10
358

-5
403

0
448

5
493

7.2
513

10
538

15
582
c

Current consumption
Comp.\C
SC12G

-35
1.56

-30
1.70

A
-25 -23.3 -20
1.84 1.89 1.98

-15
2.12

-10
2.26

-5
2.39

0
2.52

5
2.65

7.2
2.70

10
2.77

COP (EN 12900/CECOMAF)


Comp.\C
SC12G

-35
0.53

-35
0.66

15
2.88

12

13
14

W/W

-30
0.62

-25 -23.3 -20


0.77 0.83 0.95

-15
1.15

-10
1.35

-5
1.55

0
1.75

5
1.95

7.2
2.03

10
2.14

-30
0.76

-25 -23.3 -20


0.95 1.02 1.18

-15
1.42

-10
1.67

-5
1.92

0
2.16

5
2.41

7.2
2.51

10
2.65

COP (ASHRAE)
Comp.\C
SC12G

11

10

15
2.33

Start winding
Main winding
Winding protector

W/W

Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Fan cooling, 220V 50Hz

EN 12900/CECOMAF
55C
32C
55C

ASHRAE
55C
32C
32C

15
2.89

LST

b
8221

a1
d
Main winding

a1

Start winding

Accessories
Devices

Fig.

SC12G

a1

103N0002

Starting relay

a2

117U6003

Cover

103N2009

Starting capacitor 80 F

117U5017

Cord relief

103N1004

PTC starting device

6.3 mm spades

Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities

August 2001

Winding protector

118-1917
118-1918
118-1919

CD.44.P2.02

CK.40.B6.02

May 2001

167

SC15G
Universal Compressor
R134a
220-240V 50Hz
Data Sheet (Replaces CD.44.K2.02)
General
SC15G

Code number

104G8520

Code number

104G8525

Code number compressor with oil cooler

104G8530

104G

SC15G
Application

R134a

Blue stripe
Approvals

8520

Barcode on
white background

Application
Application
Evaporating temperature range
Voltage range

-35 to 15

V/Hz

LBP: 187 - 254 /50


LBP: 198 - 254 /60

S
O
F1

HBP: 198 - 254 /50


Motor type

= Static cooling normally sufficient


= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

CSIR

Max. ambient temperature

Comp. cooling at ambient temp.

DANFOSS COMPRESSORS

Yellow background

LBP/HBP

8286-2

Compressor

43

F2

32C

LBP: O/F1

38C

LBP: O/F1

43C

LBP: O/F1

HBP: F2
HBP: F2
HBP: F2

204
178
170

16

Design
Displacement

cm3

Oil quantity

cm3 600 (550 on comp. with oil cooler)

1410

kg

13.1

Motor
watt

385

LRA (rated after 4 sec. UL984) HST

14.8

Cut-in current HST

14.8

Resistance, main and start winding (25C)

209
203

B1

183

100
8.2 0.09

10.2 0.09

Process connector

location/I.D. mm

D 6.2 0.09

6.2 0.09

6.5 0.09

Discharge connector

location/I.D. mm

E 6.2 0.09

6.2 0.09

6.5 0.09

Oil cooler

location/I.D. mm

F 6.2 0.09

63

C 8.2 0.09

May 2001

B2

255

location/I.D. mm

pcs.

15
53

Suction connector

Compressors on a pallet

30

104G8520 104G8525

B2

B A

B1

104G8530
mm

C
E

EN 60335-2-34

Dimensions

168

5.0/13.7

Approvals

Height

127
165
186
218

37

37

107

80
CD.44.K3.02

CK.40.B6.02

107
115

55
63

Motor size

70
150

1300

55

Weight without electrical equipment

g
cm3

127
101.6
35

Free gas vol. in compressor

15.28

151

Maximum refrigerant charge

19
9.7

8264

August 2001

Capacity (EN 12900/CECOMAF)


Comp.\C
SC15G

-25
224

-23.3
255

-20
322

-15
440

watt
-10
579

-5
737

0
915

5
7.2
10
15
1113 1206 1330 1565
c

Capacity (ASHRAE)
Comp.\C
SC15G

-25
275

-23.3
314

watt
-20
396

-15
542

-10
714

-5
910

0
5
7.2
10
15
1132 1378 1494 1649 1945
b
8222

Power consumption
Comp.\C
SC15G

-25
270

-23.3
287

watt
-20
321

-15
373

-10
428

-5
484

0
540

5
595

7.2
620

10
650

15
703

a2
d

Current consumption
Comp.\C
SC15G

-25 -23.3 -20


2.18 2.23 2.32

-15
2.48

-10
2.64

-5
2.80

0
2.95

5
3.08

7.2
3.13

10
3.18

15
3.24

c
11

10

COP (EN 12900/CECOMAF)


Comp.\C
SC15G

-25 -23.3 -20


0.83 0.89 1.00

W/W
-15
1.18

-10
1.35

-5
1.52

0
1.70

5
1.87

7.2
1.95

10
2.05

-15
1.45

-10
1.67

-5
1.88

0
2.10

5
2.31

7.2
2.41

10
2.54

COP (ASHRAE)
Comp.\C
SC15G

-25 -23.3 -20


1.02 1.09 1.24

Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Fan cooling, 220V 50Hz

15
2.23

12

13
14

W/W

EN 12900/CECOMAF
55C
32C
55C

15
2.76

Start winding
Main winding
Winding protector

ASHRAE
55C
32C
32C

Accessories
Devices

Fig.

SC15G

Starting relay

a2

117U6005

Cover

103N2009

Starting capacitor 80 F

117U5017

Cord relief

103N1004

Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities

August 2001

118-1917
118-1918
118-1919

CD.44.K3.02

CK.40.B6.02

May 2001

169

SC18G
Universal Compressor
R134a
220-240V 50Hz
Data Sheet (Replaces CD.44.V1.02)
General
SC18G

Code number

104G8820

Code number

104G8822

Code number compressor with oil cooler

104G8830

104G

SC18G
Application

R134a

Blue stripe
Approvals

8820

Barcode on
white background

Application
Application
Evaporating temperature range
Voltage range

-35 to 15

V/Hz

LBP: 187 - 254 /50


LBP: 198 - 254 /60

S
O
F1

HBP: 198 - 254 /50


Motor type

= Static cooling normally sufficient


= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

CSIR

Max. ambient temperature

Comp. cooling at ambient temp.

DANFOSS COMPRESSORS

Yellow background

LBP/HBP

8286-8

Compressor

43

32C

F2

LBP: O/F1
HBP: F2

38C

LBP: O/F1

43C

LBP: O/F1

HBP: F2
HBP: F2

204
178
170

16

Design
cm3

600 (550 on comp. with oil cooler)

1300

cm3

1460

kg

13.7

Motor
watt

495

LRA (rated after 4 sec. UL984) HST

18.6

Cut-in current HST

18.6

Resistance, main and start winding (25C)

104G8830
A

219
213

B1

193

70
150

110

C 8.2 0.09

8.2 0.09

10.2 0.09

Process connector

location/I.D. mm

D 6.2 0.09

6.2 0.09

6.5 0.09

Discharge connector

location/I.D. mm

E 6.2 0.09

6.2 0.09

6.5 0.09

Oil cooler

location/I.D. mm

F 6.2 0.09

May 2001

B2

location/I.D. mm

pcs.

15

255

Suction connector

Compressors on a pallet

30

104G8820 104G8822

B2

B A

B1

Dimensions

170

EN 60335-2-34, CCIB

mm

3.7/14.1

Approvals

Height

53

Motor size

127
165
186
218

63

Weight without electrical equipment

37

37

107

80
CD.44.V2.02

CK.40.B6.02

107
115

55
63

Free gas vol. in compressor

55

cm

127
101.6
35

Oil quantity
Maximum refrigerant charge

17.69

151

Displacement

19
9.7

8264

August 2001

Capacity (EN 12900/CECOMAF)


Comp.\C
SC18G

-25
283

-23.3
318

-20
394

-15
526

watt
-10
684

-5
870

0
5
7.2
10
15
1087 1337 1459 1624 1950
c

Capacity (ASHRAE)
Comp.\C
SC18G

-25
348

-23.3
392

watt
-20
485

-15
649

-10
844

-5
0
5
7.2
10
15
1074 1343 1655 1807 2014 2423
b
8222

Power consumption
Comp.\C
SC18G

-25 -23.3
331 351

watt
-20
389

-15
448

-10
507

-5
568

0
630

5
695

7.2
725

10
763

15
835

a2
d

Current consumption
Comp.\C
SC18G

-25 -23.3 -20


2.56 2.62 2.72

-15
2.88

-10
3.05

-5
3.24

0
3.46

5
3.71

7.2
3.84

10
4.00

15
4.34

c
11

10

COP (EN 12900/CECOMAF)


Comp.\C
SC18G

-25 -23.3
0.86 0.91

W/W

-20
1.01

-15
1.18

-10
1.35

-5
1.53

0
1.72

5
1.92

7.2
2.01

10
2.13

-25 -23.3 -20


1.05 1.12 1.25

-15
1.45

-10
1.67

-5
1.89

0
2.13

5
2.38

7.2
2.49

10
2.64

COP (ASHRAE)
Comp.\C
SC18G

Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Fan cooling, 220V 50Hz

15
2.34

12

13
14

W/W

EN 12900/CECOMAF
55C
32C
55C

15
2.90

Start winding
Main winding
Winding protector

ASHRAE
55C
32C
32C

Accessories
Devices

Fig.

SC18G

Starting relay

a2

117U6019

Cover

103N2009

Starting capacitor 80 F

117U5017

Cord relief

103N1004

Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities

August 2001

118-1917
118-1918
118-1919

CD.44.V2.02

CK.40.B6.02

May 2001

171

SC21G
Universal Compressor
R134a
220-240V 50Hz
Data Sheet (Replaces CD.44.L4.02)
General
SC21G

104G

SC21G

Code number

104G8140

Code number

104G8124

Application

R134a

Blue stripe
Approvals

Application
Application

LBP/HBP

Evaporating temperature range


Voltage range*)

8140

Barcode on
white background

8286-3

Compressor

DANFOSS COMPRESSORS

Yellow background

-35 to 15

V/Hz

LBP: 187 - 254 /50


LBP: 198 - 254 /60
S
O
F1

HBP: 198 - 254 /50


Motor type

CSR

Max. ambient temperature

Comp. cooling at ambient temp.

43

32C

F2

LBP: F2

= Static cooling normally sufficient


= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

HBP: F2
38C

LBP: F2
HBP: F2

43C

Displacement

cm3

Oil quantity

cm3

600

1300

cm3

1460

kg

13.5

Free gas vol. in compressor


Weight without electrical equipment

20.95

Motor
Motor size

watt

550

LRA (rated after 4 sec. UL984) HST

21.8

Cut-in current HST

21.8

Resistance, main and start winding (25C)

19
9.7

70
150

Maximum refrigerant charge

204
178
170

16

127
101.6
35

Design

LBP: F2

HBP: F2
*) Not applicable below -25C evaporating temperature in 43C
ambient temperature above 240V.

127
165
186
218

C
E

3.5/12.1

Approvals

EN 60335-2-34

B A

B1
B2

193

B2

110

location/I.D. mm

C 10.2 0.09

Process connector

location/I.D. mm

6.2 0.09

Discharge connector

location/I.D. mm

6.2 0.09

May 2001

pcs.

10.2 0.09
6.5 0.09

63

B1

255

37

37

55
63

219
213

A
B

Suction connector

Compressors on a pallet

172

mm

104G8124

55

Height

104G8140

151

Dimensions

6.5 0.09
80

CD.44.L5.02

CK.40.B6.02

107

107
115

8257

August 2001

Capacity (EN 12900/CECOMAF)


Comp.\C
SC21G

-25
333

-23.3
370

-20
453

-15
606

watt
-10
792

-5
0
5
7.2
10
15
1012 1268 1560 1700 1889 2256

Capacity (ASHRAE)
Comp.\C
SC21G

-25
410

-23.3
456

-25
382

-23.3
404

-20
558

-15
746

-10
977

-20
445

-15
509

-10
575

-5
643

0
714

5
789

7.2
823

10
868

15
953

-25 -23.3 -20


2.28 2.34 2.48

-15
2.71

-10
2.96

-5
3.24

0
3.54

5
3.87

7.2
4.02

10
4.22

15
4.60

-25 -23.3 -20


0.87 0.92 1.02

-25 -23.3 -20


1.07 1.13 1.25

Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Fan cooling, 220V 50Hz

8227

W/W
-15
1.19

-10
1.38

-5
1.58

0
1.78

5
1.98

7.2
2.07

10
2.18

COP (ASHRAE)
Comp.\C
SC21G

watt

COP (EN 12900/CECOMAF)


Comp.\C
SC21G

15
2.37

b
e

Start winding
5

a2

Main winding
Winding
protector
1

2
N
L

2
N
L

Bleeder resistance

a3

W/W
-15
1.47

-10
1.70

-5
0
5
7.2
10
15
1250 1568 1931 2106 2343 2803

Current consumption
Comp.\C
SC21G

a2

watt

Power consumption
Comp.\C
SC21G

a3

-5
1.95

EN 12900/CECOMAF
55C
32C
55C

0
2.20

5
2.45

7.2
2.56

10
2.70

15
2.94

Thermostat

Fan

ASHRAE
55C
32C
32C

Accessories
Devices

Fig.

SC21G

a3

117-7028 (470 mm cable length)


117-7029 (550 mm cable length)
117-7032 (650 mm cable length)
103N2009

Starting device

Cover

Starting relay

a2

Starting capacitor

Run capacitor

Cord relief

Components of
starting device
103N1004

Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities

118-1917
118-1918
118-1919

CD.44.L5.02

August 2001

CK.40.B6.02

May 2001

173

SC12/12G
Universal Twin Compressor
R134a
220-240V 50Hz
Data Sheet (Replaces CD.44.F4.02)
General
SC12/12G

Code number

104G8280

Application
Application

LBP/HBP

Evaporating temperature range


Voltage range

-35 to 15

V/Hz

104G

SC12/12G
Application

R134a

Blue stripe
Approvals

8280

Barcode on
white background

8288

Compressor

DANFOSS COMPRESSORS

Yellow background

198 - 254 /50

Motor type

CSIR

Max. ambient temperature

Comp. cooling at ambient temp.

43

32C

S
O
F1

LBP: F2
HBP: F2

38C

LBP: F2

F2

= Static cooling normally sufficient


= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

HBP: F2
43C

LBP: F2

127

HBP: F2

Design
Displacement

cm3

Oil quantity

cm3

1220

2200

cm3

2820

kg

28

Free gas vol. in compressor


Weight without electrical equipment

100

Maximum refrigerant charge

2 x 12.87

127
16

175

302

Motor
Motor size

watt

2 x 315

LRA (rated after 4 sec. UL984) HST*

Cut-in current HST*

12.6
12.6

Resistance, main and start winding (25C)

6.7/11.8

Approvals

EN 60335-2-34

B1
B2

* Operational current for the second compressor time-delayed.

Dimensions
Height

mm

249

244

B1

183

B2

100

1"-14 UNF

8260

Service valve

location/I.D. mm

12

Solder connector

location/I.D. mm

12

Process connector

location/I.D. mm

6.2 0.09

Discharge connector

location/I.D. mm

6.2 0.09

Compressors on a pallet

pcs.

320

Suction connector

18
326

May 2001

174

CD.44.F5.02

CK.40.B6.02

August 2001

Capacity (EN 12900/CECOMAF)


Comp.\C
SC12/12G

-35
156

watt

-30
230

-25
350

-23.3
400

-20
514

-15
720

-10
968

-5
1250

0
1570

5
1920

7.2
2084

10
2300

15
2708

-30
282

-25
430

-23.3
494

-20
634

-15
888

-10
1192

-5
1544

0
1920

5
2376

7.2
2582

10
2852

15
3364

-30
372

-25
454

-23.3
482

-20
539

-15
626

-10
716

-5
806

0
896

5
986

7.2
1026

10
1076

15
1163

-30
3.40

-25
3.68

-23.3
3.78

-20
3.96

-15
4.24

-10
4.52

-5
4.78

0
5.04

5
5.30

7.2
5.40

10
5.54

15
5.76

-30
0.62

-25
0.77

-23.3
0.83

-20
0.95

-15
1.15

-10
1.35

-5
1.55

0
1.75

5
1.95

7.2
2.03

10
2.14

15
2.33

-30
0.76

-25
0.95

-23.3
1.02

-20
1.18

-15
1.42

-10
1.67

-5
1.92

0
2.16

5
2.41

7.2
2.51

10
2.65

15
2.89

Capacity (ASHRAE)
Comp.\C
SC12/12G

-35
194

watt

Power consumption
Comp.\C
SC12/12G

-35
293

watt

Current consumption
Comp.\C
SC12/12G

-35
3.12

COP (EN 12900/CECOMAF)


Comp.\C
SC12/12G

-35
0.53

W/W

COP (ASHRAE)
-35
0.66

W/W

Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Fan cooling, 220V 50Hz

EN 12900/CECOMAF
55C
32C
55C

ASHRAE
55C
32C
32C

Starting relay
Starting capacitor
10 11
12

10 11
13

Main winding
14

1
2
N
L

Accessories
Devices

pcs.

SC12/12G

Starting relay

117U6003

Starting capacitor 80 F

117U5017

1
2
N
L

1
2
N
L

2 1

Cover

103N2009

Cord relief

103N1004

Time-delay relay
Check valve
(to be used with time-delay relay)

1
2

117N0001
020-1014

Service valve

118-7350
(12 mm)

Solder connector

104B0584
(12 mm)

Start winding
Winding
protector

Thermostat

12

13

14

1933

Comp.\C
SC12/12G

1
2
N
L

Blue
Black
Brown

Time delay relay


Thermostat 2

Fan

Safety pressure control


Remove wire L-1 if time delay is used

Remove wire 1-2 if thermostat 2 is used

service valve
seal ring

seal ring

Seal ring for service valve


and solder connector

118-3638
8214

Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities

August 2001

solder connector

118-1917
118-1918

CD.44.F5.02

CK.40.B6.02

May 2001

175

SC15/15G
Universal Twin Compressor
R134a
220-240V 50Hz
Data Sheet (Replaces CD.44.R1.02)
General
SC15/15G

Code number

104G8580

Application
Application

LBP/HBP

Evaporating temperature range


Voltage range

-35 to 15

V/Hz

104G

SC15/15G
Application

R134a

Blue stripe
Approvals

8580

Barcode on
white background

8288-3

Compressor

DANFOSS COMPRESSORS

Yellow background

198 - 254 /50

Motor type

CSIR

Max. ambient temperature

Comp. cooling at ambient temp.

43

32C

S
O
F1

LBP: F2
HBP: F2

38C

LBP: F2

F2

= Static cooling normally sufficient


= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

HBP: F2
43C

LBP: F2

127

HBP: F2

Design
Displacement

cm3

Oil quantity

cm3

1220

2200

cm3

2820

kg

28

Free gas vol. in compressor


Weight without electrical equipment

100

Maximum refrigerant charge

2 x 15.28

127
16

175

302

Motor
Motor size

watt

2 x 385

LRA (rated after 4 sec. UL984) HST*

Cut-in current HST*

14.8
14.8

Resistance, main and start winding (25C)

5.0/13.7

Approvals

EN 60335-2-34

B1
B2

* Operational current for the second compressor time-delayed.

Dimensions
Height

mm

249

244

B1

183

B2

100

1"-14 UNF

8260

Service valve

location/I.D. mm

12

Solder connector

location/I.D. mm

12

Process connector

location/I.D. mm

6.2 0.09

Discharge connector

location/I.D. mm

6.2 0.09

Compressors on a pallet

pcs.

320

Suction connector

18
326

May 2001

176

CD.44.R2.02

CK.40.B6.02

August 2001

Capacity (EN 12900/CECOMAF)


Comp.\C
SC15/15G

-25
448

watt

-23.3
510

-20
644

-15
880

-10
1158

-5
1474

0
1830

5
2226

7.2
2412

10
2660

15
3130

-23.3
628

-20
792

-15
1084

-10
1428

-5
1820

0
2264

5
2756

7.2
2988

10
3298

15
3890

-23.3
574

-20
641

-15
747

-10
856

-5
967

0
1079

5
1191

7.2
1239

10
1300

15
1407

-23.3
4.46

-20
4.64

-15
4.96

-10
5.28

-5
5.60

0
5.90

5
6.16

7.2
6.26

10
6.36

15
6.48

Capacity (ASHRAE)
Comp.\C
SC15/15G

-25
550

watt

Power consumption
Comp.\C
SC15/15G

-25
540

watt

Current consumption
Comp.\C
SC15/15G

-25
4.36

COP (EN 12900/CECOMAF)


Comp.\C
SC15/15G

W/W

-25
0.83

-23.3
0.89

-20
1.00

-15
1.18

-10
1.35

-5
1.52

0
1.70

5
1.87

7.2
1.95

10
2.05

15
2.23

-25
1.02

-23.3
1.09

-20
1.24

-15
1.45

-10
1.67

-5
1.88

0
2.10

5
2.31

7.2
2.41

10
2.54

15
2.76

COP (ASHRAE)

W/W

Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Fan cooling, 220V 50Hz

EN 12900/CECOMAF
55C
32C
55C

ASHRAE
55C
32C
32C

Starting relay
Starting capacitor
10 11
12

10 11
13

Main winding
14

1
2
N
L

Accessories
Devices

pcs.

SC15/15G

Starting relay

117U6005

Starting capacitor 80 F

117U5017

1
2
N
L

1
2
N
L

2 1

Cover

103N2009

Cord relief

103N1004

Time-delay relay
Check valve
(to be used with time-delay relay)

1
2

117N0001
020-1014

Service valve

118-7350
(12 mm)

Solder connector

104B0584
(12 mm)

Start winding
Winding
protector

Thermostat

12

13

14

1933

Comp.\C
SC15/15G

1
2
N
L

Blue
Black
Brown

Time delay relay


Thermostat 2

Fan

Safety pressure control


Remove wire L-1 if time delay is used

Remove wire 1-2 if thermostat 2 is used

service valve
seal ring

seal ring

Seal ring for service valve


and solder connector

118-3638
8214

Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities

August 2001

solder connector

118-1917
118-1918

CD.44.R2.02

CK.40.B6.02

May 2001

177

SC18/18G
Universal Twin Compressor
R134a
220-240V 50Hz
Data Sheet (Replaces CD.44.U1.02)
General
SC18/18G

Code number

104G8880

Application
Application
Evaporating temperature range
Voltage range

C
V/Hz

R134a

LBP/HBP

Blue stripe
Approvals

-35 to 15

Barcode on
white background

198 - 254 /50

Motor type

104G

SC18/18G
Application

8880

8288-4

Compressor

DANFOSS COMPRESSORS

Yellow background

CSIR

Max. ambient temperature

Comp. cooling at ambient temp.

43

32C

S
O
F1

LBP: F2
HBP: F2

38C

LBP: F2

F2

= Static cooling normally sufficient


= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

HBP: F2
43C

LBP: F2

127

HBP: F2

Design
Displacement

cm3

Oil quantity

cm3

1220

2200

cm3

2920

kg

28

Free gas vol. in compressor


Weight without electrical equipment

100

Maximum refrigerant charge

2 x 17.69

127
16

175

302

Motor
Motor size

watt

2 x 495

LRA (rated after 4 sec. UL984) HST*

Cut-in current HST*

18.6
18.6

Resistance, main and start winding (25C)

3.7/14.1

Approvals

EN 60335-2-34, CCIB

B1
B2

* Operational current for the second compressor time-delayed.

Dimensions
Height

mm

259

254

B1

193

B2

110

1"-14 UNF

8260

Service valve

location/I.D. mm

16

Solder connector

location/I.D. mm

16

Process connector

location/I.D. mm

6.2 0.09

Discharge connector

location/I.D. mm

6.2 0.09

Compressors on a pallet

pcs.

320

Suction connector

18
326

May 2001

178

CD.44.U2.02

CK.40.B6.02

August 2001

Capacity (EN 12900/CECOMAF)


Comp.\C
SC18/18G

-25
566

watt

-23.3
636

-20
788

-15
1052

-10
1368

-5
1740

0
2174

5
2674

7.2
2918

10
3248

15
3900

-23.3
784

-20
970

-15
1298

-10
1688

-5
2148

0
2686

5
3310

7.2
3614

10
4028

15
4846

-23.3
702

-20
778

-15
896

-10
1014

-5
1136

0
1260

5
1390

7.2
1450

10
1526

15
1670

-23.3
5.24

-20
5.44

-15
5.76

-10
6.10

-5
6.48

0
6.92

5
7.42

7.2
7.68

10
8.00

15
8.68

Capacity (ASHRAE)
Comp.\C
SC18/18G

-25
696

watt

Power consumption
Comp.\C
SC18/18G

-25
662

watt

Current consumption
Comp.\C
SC18/18G

-25
5.12

COP (EN 12900/CECOMAF)


Comp.\C
SC18/18G

W/W

-25
0.86

-23.3
0.91

-20
1.01

-15
1.18

-10
1.35

-5
1.53

0
1.72

5
1.92

7.2
2.01

10
2.13

15
2.34

-25
1.05

-23.3
1.12

-20
1.25

-15
1.45

-10
1.67

-5
1.89

0
2.13

5
2.38

7.2
2.49

10
2.64

15
2.90

COP (ASHRAE)

W/W

Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Fan cooling, 220V 50Hz

EN 12900/CECOMAF
55C
32C
55C

ASHRAE
55C
32C
32C

Starting relay
Starting capacitor
10 11
12

10 11
13

Main winding
14

1
2
N
L

Accessories
Devices

pcs.

SC18/18G

Starting relay

117U6019

Starting capacitor 80 F

117U5017

Start winding
Winding
protector

1
2
N
L

1
2
N
L

2 1

Thermostat

12

13

14

1933

Comp.\C
SC18/18G

1
2
N
L

Blue
Black
Brown

Time delay relay


Thermostat 2

Fan

Safety pressure control

Cover

103N2009

Cord relief

103N1004

Time-delay relay
Check valve
(to be used with time-delay relay)

1
2

117N0001
020-1014

Service valve

118-7351
(16 mm)

Solder connector

118-7405 (16 mm)

Remove wire L-1 if time delay is used

Remove wire 1-2 if thermostat 2 is used

service valve
seal ring

seal ring

Seal ring for service valve


and solder connector

118-3638
8214

Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities

August 2001

solder connector

118-1917
118-1918

CD.44.U2.02

CK.40.B6.02

May 2001

179

SC21/21G
Universal Twin Compressor
R134a
220-240V 50Hz
Data Sheet (Replaces CD.44.J3.02)
General
SC21/21G

Code number

104G8180

R134a

Blue stripe
Approvals

Application
Application
Evaporating temperature range
Voltage range*)

C
V/Hz

8180

LBP/HBP

Barcode on
white background

-35 to 15

Yellow background

DANFOSS COMPRESSORS

198 - 254 /50

Motor type

CSR

Max. ambient temperature


Comp. cooling at ambient temp.

43

32C

F2

38C

F2

43C

F2

S
O
F1
F2

= Static cooling normally sufficient


= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

*) Not applicable below -25C evaporating temperature in 43C


ambient temperature above 240V.

Displacement

cm3

Oil quantity

cm3

1220

2200

cm3

2920

kg

28

Maximum refrigerant charge


Free gas vol. in compressor
Weight without electrical equipment

127

2 x 20.95

100

Design

104G

SC21/21G
Application

8288-2

Compressor

127
16

Motor
Motor size

watt

LRA (rated after 4 sec. UL984) HST*

175

2 x 550

302

21.8

Cut-in current HST*

21.8

Resistance, main and start winding (25C)

3.5/12.1

Approvals

EN 60335-2-34
* Operational current for the second compressor time-delayed.

Dimensions
Height

B1
B2

mm

259

254

B1

193

B2

110

1"-14 UNF

8265

Service valve

location/I.D. mm

16

Solder connector

location/I.D. mm

16

Process connector

location/I.D. mm

6.2 0.09

Discharge connector

location/I.D. mm

6.2 0.09

Compressors on a pallet

pcs.

320

Suction connector

18

326

May 2001

180

CD.44.J4.02

CK.40.B6.02

August 2001

Capacity (EN 12900/CECOMAF)


Comp.\C
SC21/21G

-25
667

watt

-23.3
741

-20
907

-15
1212

-10
1584

-5
2025

0
2536

5
3120

7.2
3400

10
3778

15
4511

-23.3
912

-20
1116

-15
1493

-10
1953

-5
2500

0
3135

5
3862

7.2
4212

10
4684

15
5605

-23.3
815

-20
899

-15
1026

-10
1156

-5
1289

0
1430

5
1581

7.2
1651

10
1744

15
1921

-23.3
4.68

-20
4.96

-15
5.42

-10
5.92

-5
6.48

0
7.08

5
7.74

7.2
8.04

10
8.44

15
9.20

Capacity (ASHRAE)
Comp.\C
SC21/21G

-25
820

watt

Power consumption
Comp.\C
SC21/21G

-25
771

watt

Current consumption
Comp.\C
SC21/21G

-25
4.56

COP (EN 12900/CECOMAF)


Comp.\C
SC21/21G

W/W

-25
0.87

-23.3
0.92

-20
1.02

-15
1.19

-10
1.38

-5
1.58

0
1.78

5
1.98

7.2
2.07

10
2.18

15
2.37

-25
1.07

-23.3
1.13

-20
1.25

-15
1.47

-10
1.70

-5
1.95

0
2.20

5
2.45

7.2
2.56

10
2.70

15
2.94

COP (ASHRAE)

W/W

Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Fan cooling, 220V 50Hz

EN 12900/CECOMAF
55C
32C
55C

ASHRAE
55C
32C
32C

Winding protector
Starting capacitor
Main winding Starting relay
Run capacitor
Start winding
Bleeder resistance

1
2
N
L

Accessories
Devices

pcs.

SC21/21G

117-7028 (470 mm cable length)


117-7029 (550 mm cable length)
117-7032 (650 mm cable length)

Starting device

Cover

103N2009

Cord relief

103N1004

Time-delay relay
Check valve
(to be used with time-delay relay)

1
2

117N0001
020-1014

1
2
N
L

1
2
N
L

2 1

Thermostat

1932

Comp.\C
SC21/21G

1
2
N
L

Blue
Black
Brown

Time delay
relay
Safety pressure control

Remove wire L-1 if time delay is used

Fan

Thermostat 2

Remove wire 1-2 if thermostat 2 is used

service valve
seal ring

Service valve

118-7351 (16 mm)

Solder connector

118-7405 (16 mm)

Seal ring for service valve


and solder connector

118-3638

seal ring

8214

Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities

August 2001

solder connector

118-1917
118-1918

CD.44.J4.02

CK.40.B6.02

May 2001

181

TL4GH
Heat Pump Compressor
R134a
220-240V 50/60Hz
Data Sheet (Replaces CD.42.P4.02)
General
TL4GH

Code number

102G4455

102G

TL4GH
Application

R134a

Blue stripe
Approvals

Application
Application
Evaporating temperature range
Voltage range

C
V/Hz

HBP

Barcode on
white background

-15 to 15

Yellow background

4455

8289

Compressor

DANFOSS COMPRESSORS

198 - 254 /50

198 - 254 /60

TL4GH
230V-60Hz
1PH

CSIR

Max. ambient temperature


Comp. cooling at ambient temp.

43

32C

F2

38C

F2

43C

F2

THERMALLY
PROTECTED

Approval mark
S
O
F1

Design
Displacement

cm3

3.86

Oil quantity

cm3

280

Maximum refrigerant charge


Free gas vol. in compressor

600
1690

kg

7.5

F2

= Static cooling normally sufficient


= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

16

35
70
100

Weight without electrical equipment

g
cm3

8289-2

Motor type

Motor
Motor size

watt

140

LRA (rated after 4 sec. UL984) HST

5.7

Cut-in current HST

5.7

Resistance, main and start winding (25C)

14.5/14.8

Approvals

EN 60335-2-34, UL984/CSA-C22.2

9
170
178
186
204

C or
D

Dimensions
173
169

6.2 0.09

Process connector

location/I.D. mm

6.2 0.09

Discharge connector

location/I.D. mm

5.0 +0.12/+0.20

Compressors on a pallet

pcs.

A B

105
107

B
location/I.D. mm

30

105

Suction connector

mm

31.5
28

Height

D
C

or

222
176

125

102

May 2001

182

CD.42.P5.02

CK.40.B6.02

71

29

51 20

45

157
60.5
66

8263

96
117

August 2001

Capacity (EN 12900/CECOMAF)


Evap. temp in C
TL4GH, 50Hz
TL4GH, 60Hz

-15
104
118

watt

-10
140
160

-5
182
208

0
230
264

5
287
328

7.2
315
360

10
353
403

-10
173
198

-5
225
257

0
285
327

5
356
408

7.2
391
447

10
439
501

Capacity (ASHRAE)
Evap. temp in C
TL4GH, 50Hz
TL4GH, 60Hz

-15
129
146

-15
109
123

watt

Power consumption
Evap. temp in C
TL4GH, 50Hz
TL4GH, 60Hz

15
429
489

15
535
609

watt
-10
121
139

-5
134
156

0
146
174

5
159
193

7.2
164
202

10
171
213

8219

15
181
232

a2
d

Current consumption
Evap. temp in C
TL4GH, 50Hz
TL4GH, 60Hz

-15
0.97
0.89

A
-10
1.01
0.95

-5
1.05
1.02

0
1.09
1.09

5
1.12
1.16

7.2
1.14
1.19

10
1.16
1.23

15
1.20
1.31

c
11

10

COP (EN 12900/CECOMAF)


Evap. temp in C
TL4GH, 50Hz
TL4GH, 60Hz

W/W

-15
0.96
0.96

-10
1.16
1.15

-5
1.36
1.33

0
1.57
1.51

5
1.81
1.70

7.2
1.92
1.78

10
2.07
1.90

-15
1.18
1.19

-10
1.43
1.43

-5
1.68
1.65

0
1.95
1.88

5
2.24
2.11

7.2
2.38
2.22

10
2.57
2.36

COP (ASHRAE)
Evap. temp in C
TL4GH, 50Hz
TL4GH, 60Hz

15
2.37
2.11

12

13
14

W/W

Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
50Hz: Fan cooling F2, 220V
60Hz: Fan cooling F2, 220V

EN 12900/CECOMAF
55C
32C
55C

15
2.95
2.63

Main winding

Winding protector Start winding

ASHRAE
55C
32C
32C

Accessories
Devices

Fig.

TL4GH

Starting relay

a2

117U6000

Cover

103N2011

Starting capacitor 60 F

117U5014

Cord relief

103N1010

Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities

August 2001

118-1917
118-1918
118-1919

CD.42.P5.02

CK.40.B6.02

May 2001

183

FR7GH
Heat Pump Compressor
R134a
220-240V 50/60Hz
Data Sheet (Replaces CD.43.L4.02)
General
FR7GH

Code number

103G6683

Code number compressor with oil cooler

103G6692

103G

FR7GH
Application

R134a

Blue stripe
Approvals

6692

Barcode on
white background

Application
Application

HBP

Voltage range

DANFOSS COMPRESSORS

Yellow background

-15 to 15

V/Hz

198 - 254 /50

FR7GH
230V-60Hz
1PH

198 - 254 /60


Motor type

CSIR

Max. ambient temperature

Comp. cooling at ambient temp.

43

32C

O/F1

38C

O/F1

THERMALLY
PROTECTED

Approval mark

43C

O/F1

S
O
F1

cm3

6.93

F2

Design
Displacement
Oil quantity

450

900

cm

1350

kg

10.6

watt

235

9.1

cm

Maximum refrigerant charge


Free gas vol. in compressor

= Static cooling normally sufficient


= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

204
178

16

19

35
127
150

101.6
70
60.5

Weight without electrical equipment

8290-2

Evaporating temperature range

8290

Compressor

Motor
Motor size
LRA (rated after 4 sec. UL984) HST
Cut-in current HST

9.1

Resistance, main and start winding (25C)

8.80/12.0

127
165
170
186
200

C
E

EN 60335-2-34, UL984/CSA-C22.2

30

30

Approvals

9.7

location/I.D. mm

8.2 0.09

Process connector

location/I.D. mm

6.2 0.09

Discharge connector

location/I.D. mm

8.2 0.09

Oil cooler

location/I.D. mm

8.2 0.09

pcs.

80

102
130

243
264

122.5

May 2001

184

CD.43.L5.02

CK.40.B6.02

F
8266

55

Compressors on a pallet

34

Suction connector

40

191

24

32
55

A B

40

196

40

127

mm

156

Height

25

Dimensions

124.5
127.5

August 2001

Capacity (EN 12900/CECOMAF)


Evap. temp in C
FR7GH, 50Hz
FR7GH, 60Hz

-15
199
225

watt

-10
255
294

-5
327
379

0
417
482

5
525
607

7.2
580
668

10
655
753

-10
316
363

-5
405
469

0
516
598

5
652
753

7.2
720
830

10
814
936

15
807
924

Capacity (ASHRAE)
Evap. temp in C
FR7GH, 50Hz
FR7GH, 60Hz

-15
246
278

watt
15
1005
1151

Power consumption
Evap. temp in C
FR7GH, 50Hz
FR7GH, 60Hz

-15
165
184

watt
-10
192
217

-5
217
251

0
239
284

5
258
317

7.2
266
331

10
274
350

8219

15
288
383

a2
d

Current consumption
Evap. temp in C
FR7GH, 50Hz
FR7GH, 60Hz

-15
1.38
1.31

A
-10
1.47
1.41

-5
1.55
1.53

0
1.63
1.65

5
1.70
1.79

7.2
1.72
1.86

10
1.76
1.94

15
1.81
2.10

c
11

10

COP (EN 12900/CECOMAF)


Evap. temp in C
FR7GH, 50Hz
FR7GH, 60Hz

W/W

-15
1.21
1.22

-10
1.33
1.35

-5
1.51
1.51

0
1.74
1.70

5
2.04
1.91

7.2
2.18
2.02

10
2.39
2.15

-15
1.49
1.51

-10
1.64
1.67

-5
1.86
1.87

0
2.16
2.11

5
2.52
2.37

7.2
2.71
2.50

10
2.97
2.68

COP (ASHRAE)
Evap. temp in C
FR7GH, 50Hz
FR7GH, 60Hz

15
2.80
2.42

12

13
14

W/W

Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
50Hz: Oil or Fan cooling, 220V
60Hz: Oil or Fan cooling, 220V

EN 12900/CECOMAF
55C
32C
55C

15
3.49
3.01

Main winding

Winding protector Start winding

ASHRAE
55C
32C
32C

Accessories
Devices

Fig.

FR7GH

Starting relay

a2

117U6016

Cover

103N2011

Starting capacitor 80 F

117U5015

Cord relief

103N1010

Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities

August 2001

118-1917
118-1918
118-1919

CD.43.L5.02

CK.40.B6.02

May 2001

185

SC10GH
Heat Pump Compressor
R134a
220-240V 50Hz
Data Sheet (Replaces CD.44.D4.02)
General
SC10GH

Code number

104G8040

104G

SC10GH
Application

R134a

Blue stripe
Approvals

Application
Application
Evaporating temperature range
Voltage range

C
V/Hz

HBP

Barcode on
white background

-15 to 15

Yellow background

8040

DANFOSS COMPRESSORS

8291

Compressor

198 - 254 /50

Motor type

CSIR

Max. ambient temperature

43

32C

F1

38C

F1

43C

F1

Displacement

cm3

10.29

Oil quantity

cm3

500

1300

cm3

1510

kg

12.2

Comp. cooling at ambient temp.

S
O
F1
F2

= Static cooling normally sufficient


= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

Design

Maximum refrigerant charge


Free gas vol. in compressor
Weight without electrical equipment

204
178
170

16

19
9.7

LRA (rated after 4 sec. UL984) HST

watt

250

10.8

Cut-in current HST

10.8

Resistance, main and start winding (25C)

8.5/14.1

Approvals

EN 60335-2-34

70
150

Motor size

127
101.6
35

Motor

127
165
186
218

Dimensions

E
A

199

193

B1

173

B2

90
10.2 0.09

Suction connector

location/I.D. mm

Process connector

location/I.D. mm

6.2 0.09

Discharge connector

location/I.D. mm

8.2 0.09

pcs.

B2

255

80
55

63

151

Compressors on a pallet

B A

B1

37

37

107

May 2001

186

CD.44.D5.02

CK.40.B6.02

107
115

55
63

mm

Height

8258

August 2001

Capacity (EN 12900/CECOMAF)


Comp.\C
SC10GH

-15
259

-10
352

-5
467

watt
0
604

5
762

10
942

15
1144
c

Capacity (ASHRAE)
Comp.\C
SC10GH

-15
319

-10
434

watt
-5
577

0
746

5
943

10
1168

15
1421
b
8222

Power consumption
Comp.\C
SC10GH

-15
245

-10
284

watt
-5
323

0
359

5
392

10
421

15
443

a2
d

Current consumption
Comp.\C
SC10GH

-15
1.65

-10
1.80

A
-5
1.94

0
2.08

5
2.20

10
2.31

15
2.41

c
11

10

COP (EN 12900/CECOMAF)


Comp.\C
SC10GH

-15
1.06

W/W

-10
1.24

-5
1.45

0
1.68

5
1.94

10
2.24

-10
1.53

-5
1.79

0
2.08

5
2.40

10
2.78

COP (ASHRAE)
Comp.\C
SC10GH

-15
1.30

15
2.58

12

13
14

W/W

Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Fan cooling, 220V 50Hz

EN 12900/CECOMAF
55C
32C
55C

Start winding

15
3.21

Main winding
Winding protector

ASHRAE
55C
32C
32C

Accessories
Devices

Fig.

SC10GH

Starting Relay

a2

117U6002

Cover

103N2009

Starting capacitor 80 F

117U5017

Cord relief

103N1004

Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities

August 2001

118-1917
118-1918
118-1919

CD.44.D5.02

CK.40.B6.02

May 2001

187

SC12GH
Heat Pump Compressor
R134a
220-240V 50Hz
Data Sheet (Replaces CD.44.Q1.02)
General
SC12GH

Code number

104G8260

104G

SC12GH
Application

R134a

Blue stripe
Approvals

Application
Application
Evaporating temperature range
Voltage range

C
V/Hz

HBP

Barcode on
white background

-15 to 15

Yellow background

8260

8291-3

Compressor

DANFOSS COMPRESSORS

198 - 254 /50

Motor type

CSIR

Max. ambient temperature

43

32C

F1

38C

F1

43C

F1

Displacement

cm3

12.87

Oil quantity

cm3

500

1300

cm3

1510

kg

12.6

Comp. cooling at ambient temp.

S
O
F1
F2

= Static cooling normally sufficient


= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

Design

Maximum refrigerant charge


Free gas vol. in compressor
Weight without electrical equipment

204
178
170

16

19
9.7

LRA (rated after 4 sec. UL984) HST

watt

315

12.6

Cut-in current HST

12.6

Resistance, main and start winding (25C)

6.7/11.8

Approvals

EN 60335-2-34

70
150

Motor size

127
101.6
35

Motor

127
165
186
218

Dimensions

E
A

209

203

B1

183

B2

100
10.2 0.09

Suction connector

location/I.D. mm

Process connector

location/I.D. mm

6.2 0.09

Discharge connector

location/I.D. mm

8.2 0.09

pcs.

B2

255

80
55

63

151

Compressors on a pallet

B A

B1

37

37

107

May 2001

188

CD.44.Q2.02

CK.40.B6.02

107
115

55
63

mm

Height

8258

August 2001

Capacity (EN 12900/CECOMAF)


Comp.\C
SC12GH

-15
300

-10
415

-5
556

watt
0
723

5
915

10
1134

15
1378
c

Capacity (ASHRAE)
Comp.\C
SC12GH

-15
370

-10
512

watt
-5
686

0
893

5
1133

10
1406

15
1712
b
8222

Power consumption
Comp.\C
SC12GH

-15
257

-10
316

watt
-5
369

0
415

5
454

10
487

15
512

a2
d

Current consumption
Comp.\C
SC12GH

-15
1.94

-10
2.15

A
-5
2.33

0
2.50

5
2.65

10
2.78

15
2.89

c
11

10

COP (EN 12900/CECOMAF)


Comp.\C
SC12GH

-15
1.17

W/W

-10
1.31

-5
1.51

0
1.74

5
2.02

10
2.33

-10
1.62

-5
1.86

0
2.15

5
2.49

10
2.89

COP (ASHRAE)
Comp.\C
SC12GH

-15
1.44

15
2.69

12

13
14

W/W

Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Fan cooling, 220V 50Hz

EN 12900/CECOMAF
55C
32C
55C

Start winding

15
3.34

Main winding
Winding protector

ASHRAE
55C
32C
32C

Accessories
Devices

Fig.

SC12GH

Starting Relay

a2

117U6003

Cover

103N2009

Starting capacitor 80 F

117U5017

Cord relief

103N1004

Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities

August 2001

118-1917
118-1918
118-1919

CD.44.Q2.02

CK.40.B6.02

May 2001

189

SC15GH
Heat Pump Compressor
R134a
220-240V 50Hz
Data Sheet (Replaces CD.44.I4.02)
General
SC15GH

Code number

104G8560

Application
Application

HBP

Evaporating temperature range


Voltage range

-15 to 15

V/Hz

104G

SC15GH
Application

R134a

Blue stripe
Approvals

8560

Barcode on
white background

8291-4

Compressor

DANFOSS COMPRESSORS

Yellow background

198 - 254 /50

Motor type

CSIR

Max. ambient temperature


Comp. cooling at ambient temp.

43

32C

F1

38C

F1

43C

F1

S
O
F1
F2

= Static cooling normally sufficient


= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

Design
Displacement

cm3

Oil quantity

cm3

500

1300

cm3

1410

kg

13.5

Maximum refrigerant charge


Free gas vol. in compressor
Weight without electrical equipment

15.28

204
178
170

16

19
9.7

LRA (rated after 4 sec. UL984) HST

watt

385

14.8

Cut-in current HST

14.8

Resistance, main and start winding (25C)

5.0/13.7

Approvals

EN 60335-2-34

70
150

Motor size

127
101.6
35

Motor

127
165
186
218

Dimensions

E
A

209

203

B1

183

B2

100
10.2 0.09

Suction connector

location/I.D. mm

Process connector

location/I.D. mm

6.2 0.09

Discharge connector

location/I.D. mm

8.2 0.09

pcs.

B2

255

80
55

63

151

Compressors on a pallet

B A

B1

37

37

107

May 2001

190

CD.44.I5.02

CK.40.B6.02

107
115

55
63

mm

Height

8258

August 2001

Capacity (EN 12900/CECOMAF)


Comp.\C
SC15GH

-15
435

-10
573

-5
731

watt
0
916

5
1139

10
1407

15
1731
c

Capacity (ASHRAE)
Comp.\C
SC15GH

-15
536

-10
707

watt
-5
902

0
1133

5
1410

10
1745

15
2150
b
8222

Power consumption
Comp.\C
SC15GH

-15
360

-10
424

watt
-5
482

0
535

5
586

10
638

15
692

a2
d

Current consumption
Comp.\C
SC15GH

-15
2.47

-10
2.64

A
-5
2.83

0
3.04

5
3.26

10
3.48

15
3.70

c
11

10

COP (EN 12900/CECOMAF)


Comp.\C
SC15GH

-15
1.21

W/W

-10
1.35

-5
1.52

0
1.71

5
1.94

10
2.21

-10
1.67

-5
1.87

0
2.12

5
2.41

10
2.74

COP (ASHRAE)
Comp.\C
SC15GH

-15
1.49

15
2.50

12

13
14

W/W

Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Fan cooling, 220V 50Hz

EN 12900/CECOMAF
55C
32C
55C

Start winding

15
3.11

Main winding
Winding protector

ASHRAE
55C
32C
32C

Accessories
Devices

Fig.

SC15GH

Starting relay

a2

117U6005

Cover

103N2009

Starting capacitor 80 F

117U5017

Cord relief

103N1004

Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities

August 2001

118-1917
118-1918
118-1919

CD.44.I5.02

CK.40.B6.02

May 2001

191

SC18GH
Heat Pump Compressor
R134a
220-240V 50Hz
Data Sheet (Replaces CD.44.W1.02)
General
SC18GH

Code number

104G8860

104G

SC18GH
Application

R134a

Blue stripe
Approvals

Application
Application
Evaporating temperature range
Voltage range

C
V/Hz

HBP

Barcode on
white background

-15 to 15

Yellow background

8860

8291-2

Compressor

DANFOSS COMPRESSORS

198 - 254 /50

Motor type

CSIR

Max. ambient temperature

43

32C

F2

38C

F2

43C

F2

Displacement

cm3

17.69

Oil quantity

cm3

500

1300

cm3

1460

kg

13.7

Comp. cooling at ambient temp.

S
O
F1
F2

= Static cooling normally sufficient


= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

Design

Maximum refrigerant charge


Free gas vol. in compressor
Weight without electrical equipment

204
178
170

16

19
9.7

LRA (rated after 4 sec. UL984) HST

watt

495

18.6

Cut-in current HST

18.6

Resistance, main and start winding (25C)

3.7/14.1

Approvals

EN 60335-2-34

70
150

Motor size

127
101.6
35

Motor

127
165
186
218

Dimensions

E
A

219

213

B1

193

B2

110
10.2 0.09

Suction connector

location/I.D. mm

Process connector

location/I.D. mm

6.2 0.09

Discharge connector

location/I.D. mm

8.2 0.09

pcs.

B2

255

80
55

63

151

Compressors on a pallet

B A

B1

37

37

107

May 2001

192

CD.44.W2.02

CK.40.B6.02

107
115

55
63

mm

Height

8258

August 2001

Capacity (EN 12900/CECOMAF)


Comp.\C
SC18GH

-15
539

-10
676

-5
855

watt
0
1077

5
1340

10
1645

15
1990
c

Capacity (ASHRAE)
Comp.\C
SC18GH

-15
664

-10
833

watt
-5
1056

0
1331

5
1659

10
2039

15
2472
b
8222

Power consumption
Comp.\C
SC18GH

-15
425

-10
498

watt
-5
567

0
633

5
697

10
758

15
817

a2
d

Current consumption
Comp.\C
SC18GH

-15
2.90

-10
3.13

A
-5
3.36

0
3.60

5
3.85

10
4.11

15
4.38

c
11

10

COP (EN 12900/CECOMAF)


Comp.\C
SC18GH

-15
1.27

W/W

-10
1.36

-5
1.51

0
1.70

5
1.92

10
2.17

-10
1.67

-5
1.86

0
2.10

5
2.38

10
2.69

COP (ASHRAE)
Comp.\C
SC18GH

-15
1.56

15
2.44

12

13
14

W/W

Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Fan cooling, 220V 50Hz

EN 12900/CECOMAF
55C
32C
55C

Start winding

15
3.03

Main winding
Winding protector

ASHRAE
55C
32C
32C

Accessories
Devices

Fig.

SC18GH

Starting relay

a2

117U6019

Cover

103N2009

Starting capacitor 80 F

117U5017

Cord relief

103N1004

Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities

August 2001

118-1917
118-1918
118-1919

CD.44.W2.02

CK.40.B6.02

May 2001

193

SC10GHH
Heat Pump Compressor
R134a
220-240V 50Hz
Data Sheet (Replaces CD.44.E5.02)
General
SC10GHH

Code number compressor with oil cooler

104G8071

104G

SC10GHH
Application

R134a

Blue stripe
Approvals

Application
Application
Evaporating temperature range
Voltage range

C
V/Hz

HBP

Barcode on
white background

-15 to 15

Yellow background

8071

8293

Compressor

DANFOSS COMPRESSORS

198 - 254 /50

Motor type

CSR

Max. ambient temperature

43

32C

38C

43C

Displacement

cm3

10.29

Oil quantity

cm3

450

1300

cm3

1640

kg

13.3

Comp. cooling at ambient temp.

S
O
F1
F2

= Static cooling normally sufficient


= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

Design

Maximum refrigerant charge


Free gas vol. in compressor
Weight without electrical equipment

204
178
170

16

19
9.7

watt

240

LRA (rated after 4 sec. UL984) HST

8.9

Cut-in current HST

8.9

Resistance, main and start winding (25C)

10.9/37.3

Approvals

EN 60335-2-34

70
150

Motor size

127
101.6
35

Motor

127
165
186
218

Dimensions

E
209

183

B2

100
10.2 0.09

Suction connector

location/I.D. mm

Process connector

location/I.D. mm

6.2 0.09

Discharge connector

location/I.D. mm

8.2 0.09

Oil cooler

location/I.D. mm

8.2 0.09

pcs.

80

30

194

CD.44.E6.02

CK.40.B6.02

B2

37

37

107

May 2001

15

255

55

Compressors on a pallet

B A

B1

53

203

B1

63

107
115

55
63

mm

151

Height

8259

August 2001

Capacity (EN 12900/CECOMAF)


Comp.\C
SC10GHH

-15
259

-10
352

-5
467

watt
0
604

5
762

10
942

Capacity (ASHRAE)
Comp.\C
SC10GHH

-15
319

-10
434

15
1144

a3
a2

watt
-5
577

0
746

5
943

10
1168

15
1421

c
8227

Power consumption
Comp.\C
SC10GHH

-15
230

-10
260

watt
-5
290

0
318

5
345

10
371

15
395

-5
1.28

0
1.40

5
1.53

10
1.66

15
1.77

Current consumption
Comp.\C
SC10GHH

-15
1.03

-10
1.15

COP (EN 12900/CECOMAF)


Comp.\C
SC10GHH

-15
1.13

-10
1.35

-15
1.39

-5
1.61

0
1.90

5
2.21

10
2.54

Start winding
5

a2

Main winding

W/W

COP (ASHRAE)
Comp.\C
SC10GHH

15
2.90

Winding
protector
1

2
N
L

2
N
L

Bleeder resistance

a3

W/W
-10
1.67

-5
1.99

Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Fan cooling, 220V 50Hz

0
2.35

5
2.73

10
3.15

EN 12900/CECOMAF
55C
32C
55C

15
3.60

Thermostat

Fan

ASHRAE
55C
32C
32C

Accessories
Devices
Starting device

Fig.

SC10GHH

a3

117-7011 (470 mm cable length)


117-7014 (1000 mm cable length)
103N2009

Cover

Starting relay

a2

Starting capacitor

Run capacitor

Cord relief

Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities

August 2001

Components of
starting device
103N1004
118-1917
118-1918
118-1919

CD.44.E6.02

CK.40.B6.02

May 2001

195

SC15GHH
Heat Pump Compressor
R134a
220-240V 50Hz
Data Sheet (CD.44.T1.02)
General
SC15GHH

Code number compressor with oil cooler

104G8571

104G

SC15GHH
Application

R134a

Blue stripe
Approvals

Application
Application
Evaporating temperature range
Voltage range

C
V/Hz

HBP

Barcode on
white background

-15 to 15

Yellow background

8571

8293-2

Compressor

DANFOSS COMPRESSORS

198 - 254 /50

Motor type

CSR

Max. ambient temperature

43

32C

38C

43C

Displacement

cm3

15.28

Oil quantity

cm3

450

1300

cm3

1540

kg

13.4

Comp. cooling at ambient temp.

S
O
F1
F2

= Static cooling normally sufficient


= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

Design

Maximum refrigerant charge


Free gas vol. in compressor
Weight without electrical equipment

204
178
170

16

19
9.7

LRA (rated after 4 sec. UL984) HST

watt

385

14.8

Cut-in current HST

14.8

Resistance, main and start winding (25C)

5.0/13.7

Approvals

EN 60335-2-34

70
150

Motor size

127
101.6
35

Motor

127
165
186
218

Dimensions

E
209

183

B2

100
10.2 0.09

Suction connector

location/I.D. mm

Process connector

location/I.D. mm

6.2 0.09

Discharge connector

location/I.D. mm

8.2 0.09

Oil cooler

location/I.D. mm

8.2 0.09

pcs.

80

30

196

CD.44.T2.02

CK.40.B6.02

B2

37

37

107

May 2001

15

255

55

Compressors on a pallet

B A

B1

53

203

B1

63

107
115

55
63

mm

151

Height

8259

August 2001

Capacity (EN 12900/CECOMAF)


Comp.\C
SC15GHH

-15
435

-10
570

-5
726

watt
0
911

5
1135

10
1405

Capacity (ASHRAE)
Comp.\C
SC15GHH

-15
536

-10
703

15
1731

a3
a2

watt
-5
896

0
1127

5
1405

10
1742

15
2150

c
8227

Power consumption
Comp.\C
SC15GHH

-15
345

-10
377

watt
-5
417

0
461

5
505

10
543

15
573

-5
2.01

0
2.20

5
2.39

10
2.56

15
2.70

Current consumption
Comp.\C
SC15GHH

-15
1.71

-10
1.84

COP (EN 12900/CECOMAF)


Comp.\C
SC15GHH

-15
1.26

-10
1.51

-5
1.74

-15
1.55

0
1.98

5
2.25

10
2.59

Start winding
5

a2

Main winding

W/W

COP (ASHRAE)
Comp.\C
SC15GHH

15
3.02

Winding
protector
1

2
N
L

2
N
L

Bleeder resistance

a3

W/W
-10
1.87

Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Fan cooling, 220V 50Hz

-5
2.15

0
2.44

5
2.78

EN 12900/CECOMAF
55C
32C
55C

10
3.21

15
3.75

Thermostat

Fan

ASHRAE
55C
32C
32C

Accessories
Devices

Fig.

SC15GHH

Starting device

a3

117-7012 (470 mm cable length)


103N2009

Cover

Starting relay

a2

Starting capacitor

Run capacitor

Cord relief

Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities

August 2001

Components of
starting device
103N1004
118-1917
118-1918
118-1919

CD.44.T2.02

CK.40.B6.02

May 2001

197

SC10GH
Heat Pump Compressor
R134a
220-240V 50/60Hz
Data Sheet (Replaces CD.44.G4.02)
General
SC10GH

Code number

104G8041

104G

SC10GH
Application

R134a

Blue stripe
Approvals

Application
Application
Evaporating temperature range
Voltage range

C
V/Hz

HBP

Barcode on
white background

-15 to 15

Yellow background

8041

DANFOSS COMPRESSORS

198 - 254 /50

8292

Compressor

198 - 254 /60

Comp. cooling at ambient temp.

43

32C

F2

38C

F2

43C

F2

THERMALLY
PROTECTED

Approval mark
S
O
F1

Design
cm3

Oil quantity

10.29

500

cm

Maximum refrigerant charge


Free gas vol. in compressor
Weight without electrical equipment

1300

cm3

1410

kg

12.2

Motor
Motor size

watt

385

LRA (rated after 4 sec. UL984) HST

14.8

Cut-in current HST

14.8

Resistance, main and start winding (25C)


Approvals

5.0/13.7

F2

= Static cooling normally sufficient


= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

204
178
170

16

19
9.7

127
101.6
35

Displacement

8292-5

SC10GH
230V-60Hz
1PH

CSIR

Max. ambient temperature

70
150

Motor type

127
165
186
218

EN 60335-2-34, UL984/CSA-C22.2

C
E

Dimensions
193

B1

173

B2

90

Suction connector

location/I.D. mm

10.2 0.09

Process connector

location/I.D. mm

6.2 0.09

Discharge connector

location/I.D. mm

8.2 0.09

pcs.

80

B2

255

55

Compressors on a pallet

B A

B1

63

199

37

37

107

May 2001

198

CD.44.G5.02

CK.40.B6.02

107
115

55
63

mm

151

Height

8258

August 2001

Capacity (EN 12900/CECOMAF)


Evap. temp in C
SC10GH, 50Hz
SC10GH, 60Hz

-15
233
318

-10
352
421

-5
478
541

watt
0
613
683

5
762
849

7.2
832
930

10
927
1042

15
1113
1265

Capacity (ASHRAE)
Evap. temp in C
SC10GH, 50Hz
SC10GH, 60Hz

-15
288
393

watt
-10
435
520

-5
591
670

0
759
846

5
945
1053

7.2
1033
1155

10
1152
1295

15
1386
1575

b
8222

Power consumption
Evap. temp in C
SC10GH, 50Hz
SC10GH, 60Hz

-15
235
287

watt
-10
281
340

-5
323
392

0
361
444

5
395
496

7.2
409
518

10
426
545

15
453
593

Current consumption
Evap. temp in C
SC10GH, 50Hz
SC10GH, 60Hz

-15
2.34
2.13

a2
d

A
-10
2.57
2.37

-5
2.80
2.63

0
3.03
2.90

5
3.26
3.18

7.2
3.36
3.30

10
3.48
3.46

15
3.70
3.76

c
11

10

COP (EN 12900/CECOMAF)


Evap. temp in C
SC10GH, 50Hz
SC10GH, 60Hz

W/W

-15
0.99
1.11

-10
1.25
1.24

-5
1.48
1.38

0
1.70
1.54

5
1.93
1.71

7.2
2.03
1.80

10
2.18
1.91

-15
1.22
1.37

-10
1.55
1.53

-5
1.83
1.71

0
2.11
1.90

5
2.39
2.13

7.2
2.53
2.23

10
2.71
2.37

15
2.46
2.13

COP (ASHRAE)
Evap. temp in C
SC10GH, 50Hz
SC10GH, 60Hz

12

13
14

W/W

Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
50Hz: Fan cooling F2, 220V
60Hz: Fan cooling F2, 220V

EN 12900/CECOMAF
55C
32C
55C

15
3.06
2.66

Start winding
Main winding
Winding protector

ASHRAE
55C
32C
32C

Accessories
Devices

Fig.

SC10GH

Starting Relay

a2

117U6005

Cover

103N2008

Starting capacitor 80 F

117U5017

Cord relief

103N1004

Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities

August 2001

118-1917
118-1918
118-1919

CD.44.G5.02

CK.40.B6.02

May 2001

199

SC12GH
Heat Pump Compressor
R134a
220-240V 50/60Hz
Data Sheet (Replaces CD.44.Z1.02)
General
SC12GH

Code number

104G8261

104G

SC12GH
Application

R134a

Blue stripe
Approvals

Application
Application
Evaporating temperature range

HBP

Barcode on
white background

50 Hz: -10 to 15

Yellow background

8261

DANFOSS COMPRESSORS

60 Hz: -15 to 15
V/Hz

198 - 254 /50

43

SC12GH
230V-60Hz
1PH

32C

F2

THERMALLY
PROTECTED

38C

F2

198 - 254 /60


Motor type

CSIR

Max. ambient temperature


Comp. cooling at ambient temp.

Approval mark

43C

F2

S
O
F1

cm3

12.87

F2

Design
Displacement
Oil quantity

500

1300

cm3

1510

kg

12.95

cm

Maximum refrigerant charge


Free gas vol. in compressor

= Static cooling normally sufficient


= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

204
178
170

16

19
9.7

Motor
Motor size

watt

470

LRA (rated after 4 sec. UL984) HST

19.7

Cut-in current HST

19.7

Resistance, main and start winding (25C)

4.3/15.3

Approvals

70
150

127
101.6
35

Weight without electrical equipment

8292-6

Voltage range

127
165
186
218

EN 60335-2-34, UL984/CSA-C22.2

Dimensions
203

B1

183

B2

100

10.2 0.09

Process connector

location/I.D. mm

6.2 0.09

Discharge connector

location/I.D. mm

8.2 0.09

Compressors on a pallet

pcs.

80

B2

255

63

B A

B1

209

37

37

107

May 2001

200

CD.44.Z2.02

CK.40.B6.02

107
115

55
63

location/I.D. mm

55

Suction connector

mm

151

Height

8292-3

Compressor

8258

August 2001

Capacity (EN 12900/CECOMAF)


Evap. temp in C
SC12GH, 50Hz
SC12GH, 60Hz

-15
371

-10
429
511

-5
577
680

watt
0
752
880

5
957
1116

7.2
1058
1233

10
1196
1393

15
1471
1714

Capacity (ASHRAE)
Evap. temp in C
SC12GH, 50Hz
SC12GH, 60Hz

-15
458

watt
-10
530
632

-5
715
841

0
932
1090

5
1188
1385

7.2
1313
1531

10
1486
1731

15
1832
2135

b
8222

Power consumption
Evap. temp in C
SC12GH, 50Hz
SC12GH, 60Hz

-15
332

watt
-10
356
389

-5
401
445

0
445
501

5
487
556

7.2
505
579

10
526
608

Current consumption
Evap. temp in C
SC12GH, 50Hz
SC12GH, 60Hz

-15
2.37

15
561
658

a2
d

A
-10
3.08
2.61

-5
3.21
2.84

0
3.34
3.06

5
3.47
3.28

7.2
3.53
3.37

10
3.60
3.49

15
3.73
3.68

c
11

10

COP (EN 12900/CECOMAF)


Evap. temp in C
SC12GH, 50Hz
SC12GH, 60Hz

-15
1.12

W/W

-10
1.20
1.31

-5
1.44
1.53

0
1.69
1.76

5
1.97
2.01

7.2
2.10
2.13

10
2.27
2.29

-10
1.49
1.62

-5
1.78
1.89

0
2.09
2.17

5
2.44
2.49

7.2
2.60
2.64

10
2.82
2.85

COP (ASHRAE)
Evap. temp in C
SC12GH, 50Hz
SC12GH, 60Hz

15
2.62
2.60

12

13
14

W/W
-15
1.38

Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
50Hz: Fan cooling F2, 220V
60Hz: Fan cooling F2, 220V

EN 12900/CECOMAF
55C
32C
55C

15
3.27
3.24

Start winding
Main winding
Winding protector

ASHRAE
55C
32C
32C

Accessories
Devices

Fig.

SC12GH

Starting Relay

a2

117U6011

Cover

103N2008

Starting capacitor 80 F

117U5017

Cord relief

103N1004

Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities

August 2001

118-1917
118-1918
118-1919

CD.44.Z2.02

CK.40.B6.02

May 2001

201

SC15GH
Heat Pump Compressor
R134a
220-240V 50/60Hz
Data Sheet (Replaces CD.44.S1.02)
General
SC15GH

Code number

104G8561

104G

SC15GH
Application

R134a

Blue stripe
Approvals

Application
Application
Evaporating temperature range

HBP

Barcode on
white background

50 Hz: -10 to 15

Yellow background

8561

DANFOSS COMPRESSORS

60 Hz: -15 to 15
V/Hz

198 - 254 /50

43

SC15GH
230V-60Hz
1PH

32C

F2

THERMALLY
PROTECTED

38C

F2

198 - 254 /60


Motor type

CSIR

Max. ambient temperature


Comp. cooling at ambient temp.

Approval mark

43C

F2

S
O
F1

cm3

15.28

F2

Design
Displacement
Oil quantity

500

1300

cm3

1410

kg

13.5

cm

Maximum refrigerant charge


Free gas vol. in compressor

= Static cooling normally sufficient


= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

204
178
170

16

19
9.7

Motor
Motor size

watt

470

LRA (rated after 4 sec. UL984) HST

19.7

Cut-in current HST

19.7

Resistance, main and start winding (25C)

4.3/15.3

Approvals

70
150

127
101.6
35

Weight without electrical equipment

8292-7

Voltage range

127
165
186
218

EN 60335-2-34, UL984/CSA-C22.2

Dimensions
203

B1

183

B2

100

10.2 0.09

Process connector

location/I.D. mm

6.2 0.09

Discharge connector

location/I.D. mm

8.2 0.09

Compressors on a pallet

pcs.

80

B2

255

63

B A

B1

209

37

37

107

May 2001

202

CD.44.S2.02

CK.40.B6.02

107
115

55
63

location/I.D. mm

55

Suction connector

mm

151

Height

8292-2

Compressor

8258

August 2001

Capacity (EN 12900/CECOMAF)


Evap. temp in C
SC15GH, 50Hz
SC15GH, 60Hz

-15
425

-10
559
582

-5
723
776

watt
0
915
1012

5
1139
1295

7.2
1249
1436

10
1398
1629

15
1698
2019

Capacity (ASHRAE)
Evap. temp in C
SC15GH, 50Hz
SC15GH, 60Hz

-15
524

watt
-10
691
719

-5
895
960

0
1134
1254

5
1413
1607

7.2
1550
1782

10
1738
2025

15
2114
2515

b
8222

Power consumption
Evap. temp in C
SC15GH, 50Hz
SC15GH, 60Hz

-15
355

watt
-10
424
424

-5
479
494

0
526
566

5
565
639

7.2
580
671

10
596
711

Current consumption
Evap. temp in C
SC15GH, 50Hz
SC15GH, 60Hz

-15
2.37

15
618
782

a2
d

A
-10
3.33
2.67

-5
3.46
2.97

0
3.59
3.24

5
3.73
3.50

7.2
3.79
3.61

10
3.87
3.74

15
4.01
3.97

c
11

10

COP (EN 12900/CECOMAF)


Evap. temp in C
SC15GH, 50Hz
SC15GH, 60Hz

-15
1.20

W/W

-10
1.32
1.37

-5
1.51
1.57

0
1.74
1.79

5
2.02
2.03

7.2
2.15
2.14

10
2.35
2.29

-10
1.63
1.70

-5
1.87
1.94

0
2.16
2.21

5
2.50
2.51

7.2
2.67
2.66

10
2.92
2.85

COP (ASHRAE)
Evap. temp in C
SC15GH, 50Hz
SC15GH, 60Hz

15
2.75
2.58

12

13
14

W/W
-15
1.48

Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
50Hz: Fan cooling F2, 220V
60Hz: Fan cooling F2, 220V

EN 12900/CECOMAF
55C
32C
55C

15
3.42
3.22

Start winding
Main winding
Winding protector

ASHRAE
55C
32C
32C

Accessories
Devices

Fig.

SC15GH

Starting Relay

a2

117U6011

Cover

103N2008

Starting capacitor 80 F

117U5017

Cord relief

103N1004

Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities

August 2001

118-1917
118-1918
118-1919

CD.44.S2.02

CK.40.B6.02

May 2001

203

SC18GH
Heat Pump Compressor
R134a
220-240V 50/60Hz
Data Sheet
General
SC18GH

Code number

104G8861

104G

SC18GH
Application

R134a

Blue stripe
Approvals

Application
Application
Evaporating temperature range
Voltage range

C
V/Hz

HBP

Barcode on
white background

-15 to 15

Yellow background

8861

DANFOSS COMPRESSORS

198 - 254 /50

8292-4

Compressor

198 - 254 /60

Max. ambient temperature


Comp. cooling at ambient temp.

43

32C

F2

38C

F2

43C

F2

THERMALLY
PROTECTED

Approval mark
S
O
F1

Design
cm3

17.69

Oil quantity

cm3

500

Maximum refrigerant charge


Free gas vol. in compressor
Weight without electrical equipment

1300

cm3

1460

kg

13.7

Motor
Motor size

watt

550

LRA (rated after 4 sec. UL984) HST

21.8

Cut-in current HST

21.8

Resistance, main and start winding (25C)


Approvals

3.5/12.1
EN 60335-2-34, UL984/CSA-C22.2

F2

= Static cooling normally sufficient


= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

204
178
170

16

19
9.7

127
101.6
35

Displacement

8292-8

SC18GH
230V-60Hz
1PH

CSR

70
150

Motor type

127
165
186
218

C
E

Dimensions

B1

193

B2

110

Suction connector

location/I.D. mm

10.2 0.09

Process connector

location/I.D. mm

6.2 0.09

Discharge connector

location/I.D. mm

8.2 0.09

pcs.

80

B2

255

55

Compressors on a pallet

B A

B1

63

219
213

37

37

107

May 2001

204

CG.44.G1.02

CK.40.B6.02

107
115

55
63

A
B

mm

151

Height

8258

August 2001

Capacity (EN 12900/CECOMAF)


Evap. temp in C
SC18GH, 50Hz
SC18GH, 60Hz

-15
485
573

-10
639
745

watt

-5
825
955

0
1047
1207

5
1310
1506

7.2
1440
1654

10
1618
1858

15
1976
2268

Capacity (ASHRAE)
Evap. temp in C
SC18GH, 50Hz
SC18GH, 60Hz

-15
600
707

-15
404
449

-10
790
921

-5
1021
1181

0
1298
1495

5
1626
1869

7.2
1788
2054

10
2011
2310

-15
2.44
2.14

-10
452
511

-5
503
577

0
554
643

5
605
708

7.2
626
736

10
651
770

15
692
826

-10
2.66
2.45

-5
2.86
2.75

0
3.06
3.05

5
3.26
3.35

7.2
3.34
3.48

10
3.45
3.65

15
3.63
3.94

8227

W/W

-15
1.20
1.27

-10
1.42
1.46

-5
1.64
1.66

0
1.89
1.88

5
2.17
2.13

7.2
2.30
2.25

10
2.49
2.41

-15
1.48
1.57

-10
1.75
1.80

-5
2.03
2.05

0
2.34
2.33

5
2.69
2.64

7.2
2.86
2.79

10
3.09
3.00

COP (ASHRAE)
Evap. temp in C
SC18GH, 50Hz
SC18GH, 60Hz

watt

COP (EN 12900/CECOMAF)


Evap. temp in C
SC18GH, 50Hz
SC18GH, 60Hz

15
2.86
2.75

b
e

Start winding
5

a2

Main winding
Winding
protector
1

2
N
L

2
N
L

Bleeder resistance

a3

W/W

Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
50Hz: Fan cooling F2, 220V
60Hz: Fan cooling F2, 220V

EN 12900/CECOMAF
55C
32C
55C

15
2461
2825

Current consumption
Evap. temp in C
SC18GH, 50Hz
SC18GH, 60Hz

a2

watt

Power consumption
Evap. temp in C
SC18GH, 50Hz
SC18GH, 60Hz

a3

15
3.56
3.42

Thermostat

Fan

ASHRAE
55C
32C
32C

Accessories
Devices
Starting device

Fig.

SC18GH

a3

117-7038 (470 mm cable length)


117-7039 (550 mm cable length)

Cover

Starting relay

a2

Starting capacitor 80 F

Run capacitor

Cord relief

Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities

August 2001

103N2008
Components
of
starting device
103N1004
118-1917
118-1918
118-1919

CG.44.G1.02

CK.40.B6.02

May 2001

205

206

CK.40.B6.02

August 2001

August 2001

CK.40.B6.02

207

The Danfoss product programme


for the refrigeration industry contains:

Compressors for Refrigeration and Air Conditioning


A wide range of hermetic reciprocating compressors and scroll compressors
as well as aircooled condensing units. The product range is applied in air
conditioning units, water chillers and commercial refrigeration systems.

Compressors for Refrigerators and Freezers


Hermetic compressors and fan-cooled condensing units for household
refrigeration units such as refrigerators and freezers, and for commercial
installations such as sales counters and bottle coolers. Compressors for
heating pump systems. 12 and 24 V compressors for refrigerators and
freezers in commercial vehicles, buses, and boats.

Appliance Controls
For the regulation of refrigeration appliances and freezers Danfoss supply a
CFC-free product range of electromechanical thermostats for refrigerators
and electromechanical thermostats for refrigerators and freezers produced
according to customer specification; Hermetic valves for refrigerator/freezer
combinations and for energy saving applications; Service thermostats for all
refrigerating and freezing appliances.

Refrigeration and Air Conditioning Controls


With our full product range we cover all the requirements for mechanical
and electronically controlled refrigeration systems. The functions cover: control,
safety, system protection and monitoring. Our products are applied for all
commercial- and industrial refrigeration applications as well as for air
conditioning.

www.danfoss.com/compressors

Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to
products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed.
All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.

Danfoss Compressors GmbH


Mads-Clausen-Strasse 7
Postfach 1443, D-24939 Flensburg
Telefon: (0461) 4941-0
International +49 461 4941-0
Telefax: +49 461 44715
Telex: 227 43 dancom d

CK.40.B6.02

Produced by Danfoss 01.08