Defect / Non Compliance Report: International Limited

1. Christopher Dieseru inspected various pieces of lifting equipment on board the Transocean Support Services HIGHISLAND VII on January 15th and 16th, 2013. 2. Defects were found in 5 shackles and 2 wire rope slings, including severe wear, stress induced cracks, incorrect pins, and chemical damage. 3. All defective equipment was deemed "not fit for use" and required removal from service.

Uploaded by

Michael Okwuwa
Copyright
© Attribution Non-Commercial (BY-NC)
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
106 views

Defect / Non Compliance Report: International Limited

1. Christopher Dieseru inspected various pieces of lifting equipment on board the Transocean Support Services HIGHISLAND VII on January 15th and 16th, 2013. 2. Defects were found in 5 shackles and 2 wire rope slings, including severe wear, stress induced cracks, incorrect pins, and chemical damage. 3. All defective equipment was deemed "not fit for use" and required removal from service.

Uploaded by

Michael Okwuwa
Copyright
© Attribution Non-Commercial (BY-NC)
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 41

JC International Limited

RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

DEFECT / NON COMPLIANCE REPORT


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

90570 Identification Number

15/01/2013

CHRISTOPHER DIESERU

LEEA, SNT LEVEL II MT, PT & UT

Qty

Description of Equipment SHACKLE

SWL

S1

Bow Screw Pin Shackle

Not Seen

LOCATION : PORT AFT


Particulars of defects found which are, or could, become a danger to persons or none Particulars of any repair, alteration to remedy defect or none

Severe wear at shackle crown Illegible SWL

Remove from service

(Not Fit for Use)


Name and address of equipment owner: Address of premises where Test / Examination was held:

Transocean Support Services HIGHISLAND VII We hereby certify that on 15/01/2013 (date) defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Conducting Examination Name of Inspector: CHRISTOPHER DIESERU Conducting: Examination only

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

DEFECT / NON COMPLIANCE REPORT


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

90571 Identification Number

15/01/2013

CHRISTOPHER DIESERU

LEEA, SNT LEVEL II MT, PT & UT

Qty

Description of Equipment SHACKLE

SWL

GR 2

Bow Safety Pin Shackle

4.75 t

LOCATION : PORT AFT


Particulars of defects found which are, or could, become a danger to persons or none Particulars of any repair, alteration to remedy defect or none

Stress induced at Crown of Shackle

Remove from service Address of premises where Test / Examination was held:

(Not Fit for Use)


Name and address of equipment owner:

Transocean Support Services HIGHISLAND VII We hereby certify that on 15/01/2013 (date) defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Conducting Examination Name of Inspector: CHRISTOPHER DIESERU Conducting: Examination only

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

DEFECT / NON COMPLIANCE REPORT


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

90572 Identification Number

15/01/2013

CHRISTOPHER DIESERU

LEEA, SNT LEVEL II MT, PT & UT

Qty

Description of Equipment SHACKLE

SWL

SS 77

Bow Safety Pin Shackle

25 t

LOCATION : PORT AFT


Particulars of defects found which are, or could, become a danger to persons or none Particulars of any repair, alteration to remedy defect or none

Stress induced at Crown of Shackle

Remove from service Address of premises where Test / Examination was held:

(Not Fit for Use)


Name and address of equipment owner:

Transocean Support Services HIGHISLAND VII We hereby certify that on 15/01/2013 (date) defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Conducting Examination Name of Inspector: CHRISTOPHER DIESERU Conducting: Examination only

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

DEFECT / NON COMPLIANCE REPORT


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

90573 Identification Number

15/01/2013

CHRISTOPHER DIESERU

LEEA, SNT LEVEL II MT, PT & UT

Qty

Description of Equipment SHACKLE

SWL

HI 221

Bow Safety Pin Shackle

25 t

LOCATION : PORT AFT


Particulars of defects found which are, or could, become a danger to persons or none Particulars of any repair, alteration to remedy defect or none

Stress induced at Crown of Shackle

Remove from service Address of premises where Test / Examination was held:

(Not Fit for Use)


Name and address of equipment owner:

Transocean Support Services HIGHISLAND VII We hereby certify that on 15/01/2013 (date) defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Conducting Examination Name of Inspector: CHRISTOPHER DIESERU Conducting: Examination only

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

DEFECT / NON COMPLIANCE REPORT


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

90574 Identification Number

15/01/2013

CHRISTOPHER DIESERU

LEEA, SNT LEVEL II MT, PT & UT

Qty

Description of Equipment SHACKLE

SWL

TS 16

Bow Safety Pin Shackle

8.5 t

LOCATION : PORT AFT


Particulars of defects found which are, or could, become a danger to persons or none Particulars of any repair, alteration to remedy defect or none

Wrong Pin

Remove from service Address of premises where Test / Examination was held:

(Not Fit for Use)


Name and address of equipment owner:

Transocean Support Services HIGHISLAND VII We hereby certify that on 15/01/2013 (date) defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Conducting Examination Name of Inspector: CHRISTOPHER DIESERU Conducting: Examination only

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

DEFECT / NON COMPLIANCE REPORT


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

90575 Identification Number

16/01/2013

CHRISTOPHER DIESERU

LEEA, SNT LEVEL II MT, PT & UT

Qty

Description of Equipment WIRE ROPE SLING

SWL

Sling ID: S1023

19mm X 5ft X 2 Legged Sling c/w Master link one end other end thimble eye.

6.4 t @ 0 0-45

LOCATION : RIG FLOOR


Particulars of defects found which are, or could, become a danger to persons or none Particulars of any repair, alteration to remedy defect or none

Chemical Damaged

Remove from service Address of premises where Test / Examination was held:

(Not Fit for Use)


Name and address of equipment owner:

Transocean Support Services HIGHISLAND VII We hereby certify that on 16/01/2013 (date) defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Conducting Examination Name of Inspector: CHRISTOPHER DIESERU Conducting: Examination only

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

DEFECT / NON COMPLIANCE REPORT


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

90576 Identification Number

16/01/2013

CHRISTOPHER DIESERU

LEEA, SNT LEVEL II MT, PT & UT

Qty

Description of Equipment WIRE ROPE SLING

SWL

Sling ID: 166454-003-001

7/8 X 6ft X Single leg sling c/w soft eyes both ends

7.6 t

LOCATION : RIG FLOOR


Particulars of defects found which are, or could, become a danger to persons or none Particulars of any repair, alteration to remedy defect or none

Permanent Bent

Remove from service Address of premises where Test / Examination was held:

(Not Fit for Use)


Name and address of equipment owner:

Transocean Support Services HIGHISLAND VII We hereby certify that on 16/01/2013 (date) defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Conducting Examination Name of Inspector: CHRISTOPHER DIESERU Conducting: Examination only

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

DEFECT / NON COMPLIANCE REPORT


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

90577 Identification Number

16/01/2013

CHRISTOPHER DIESERU

LEEA, SNT LEVEL II MT, PT & UT

Qty

Description of Equipment WIRE ROPE SLING

SWL

Sling ID: 1376768-2-1

28mm X 5ft X Single leg sling c/w thimble eyes both ends

12 t

LOCATION : RIG FLOOR


Particulars of defects found which are, or could, become a danger to persons or none Particulars of any repair, alteration to remedy defect or none

Deformed thimble and Chemical Damaged

Remove from service Address of premises where Test / Examination was held:

(Not Fit for Use)


Name and address of equipment owner:

Transocean Support Services HIGHISLAND VII We hereby certify that on 16/01/2013 (date) defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Conducting Examination Name of Inspector: CHRISTOPHER DIESERU Conducting: Examination only

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

DEFECT / NON COMPLIANCE REPORT


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

90578 Identification Number

18/01/2013

CHRISTOPHER DIESERU

LEEA, SNT LEVEL II MT, PT & UT

Qty

Description of Equipment SHACKLE

SWL

SH 7

Bow Safety Pin Shackle

6.5 t

LOCATION : RIG FLOOR


Particulars of defects found which are, or could, become a danger to persons or none Particulars of any repair, alteration to remedy defect or none

Wrong Pin

Remove from service Address of premises where Test / Examination was held:

(Not Fit for Use)


Name and address of equipment owner:

Transocean Support Services HIGHISLAND VII We hereby certify that on 18/01/2013 (date) defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Conducting Examination Name of Inspector: CHRISTOPHER DIESERU Conducting: Examination only

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

DEFECT / NON COMPLIANCE REPORT


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

90579 Identification Number

18/01/2013

CHRISTOPHER DIESERU

LEEA, SNT LEVEL II MT, PT & UT

Qty

Description of Equipment SHACKLE

SWL

SH 5

Bow Screw Pin Shackle

17 t

LOCATION : RIG FLOOR


Particulars of defects found which are, or could, become a danger to persons or none Particulars of any repair, alteration to remedy defect or none

Wrong Pin

Remove from service Address of premises where Test / Examination was held:

(Not Fit for Use)


Name and address of equipment owner:

Transocean Support Services HIGHISLAND VII We hereby certify that on 18/01/2013 (date) defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Conducting Examination Name of Inspector: CHRISTOPHER DIESERU Conducting: Examination only

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

DEFECT / NON COMPLIANCE REPORT


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

90580 Identification Number

18/01/2013

CHRISTOPHER DIESERU

LEEA, SNT LEVEL II MT, PT & UT

Qty

Description of Equipment SHACKLE

SWL

B 39

Bow Screw Pin Shackle

35 t

LOCATION : RIG FLOOR


Particulars of defects found which are, or could, become a danger to persons or none Particulars of any repair, alteration to remedy defect or none

Stress induced at Crown of shackle

Remove from service Address of premises where Test / Examination was held:

(Not Fit for Use)


Name and address of equipment owner:

Transocean Support Services HIGHISLAND VII We hereby certify that on 18/01/2013 (date) defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Conducting Examination Name of Inspector: CHRISTOPHER DIESERU Conducting: Examination only

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

DEFECT / NON COMPLIANCE REPORT


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

90581 Identification Number

18/01/2013

CHRISTOPHER DIESERU

LEEA, SNT LEVEL II MT, PT & UT

Qty

Description of Equipment SHACKLE

SWL

B 40

Bow Screw Pin Shackle

35 t

LOCATION : RIG FLOOR


Particulars of defects found which are, or could, become a danger to persons or none Particulars of any repair, alteration to remedy defect or none

Stress induced at Crown of shackle

Remove from service Address of premises where Test / Examination was held:

(Not Fit for Use)


Name and address of equipment owner:

Transocean Support Services HIGHISLAND VII We hereby certify that on 18/01/2013 (date) defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Conducting Examination Name of Inspector: CHRISTOPHER DIESERU Conducting: Examination only

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

DEFECT / NON COMPLIANCE REPORT


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

90582 Identification Number

19/01/2013

CHRISTOPHER DIESERU

LEEA, SNT LEVEL II MT, PT & UT

Qty

Description of Equipment SHACKLE

SWL

SS 31

Bow Safety Pin Shackle

55 t

LOCATION : RIG FLOOR


Particulars of defects found which are, or could, become a danger to persons or none Particulars of any repair, alteration to remedy defect or none

Stress induced at Crown of shackle

Remove from service Address of premises where Test / Examination was held:

(Not Fit for Use)


Name and address of equipment owner:

Transocean Support Services HIGHISLAND VII We hereby certify that on 19/01/2013 (date) defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Conducting Examination Name of Inspector: CHRISTOPHER DIESERU Conducting: Examination only

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

DEFECT / NON COMPLIANCE REPORT


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

90583 Identification Number

19/01/2013

CHRISTOPHER DIESERU

LEEA, SNT LEVEL II MT, PT & UT

Qty

Description of Equipment SHACKLE

SWL

SS 30

Bow Safety Pin Shackle

55 t

LOCATION : RIG FLOOR


Particulars of defects found which are, or could, become a danger to persons or none Particulars of any repair, alteration to remedy defect or none

Stress induced at Crown of shackle

Remove from service Address of premises where Test / Examination was held:

(Not Fit for Use)


Name and address of equipment owner:

Transocean Support Services HIGHISLAND VII We hereby certify that on 19/01/2013 (date) defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Conducting Examination Name of Inspector: CHRISTOPHER DIESERU Conducting: Examination only

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

DEFECT / NON COMPLIANCE REPORT


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

90584 Identification Number

19/01/2013

CHRISTOPHER DIESERU

LEEA, SNT LEVEL II MT, PT & UT

Qty

Description of Equipment SHACKLE

SWL

S09301-1

Bow Safety Pin Shackle

12 t

LOCATION : RIG FLOOR


Particulars of defects found which are, or could, become a danger to persons or none Particulars of any repair, alteration to remedy defect or none

Wrong pin (Unfitted pin)

Remove from service Address of premises where Test / Examination was held:

(Not Fit for Use)


Name and address of equipment owner:

Transocean Support Services HIGHISLAND VII We hereby certify that on 19/01/2013 (date) defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Conducting Examination Name of Inspector: CHRISTOPHER DIESERU Conducting: Examination only

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

DEFECT / NON COMPLIANCE REPORT


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

90585 Identification Number

19/01/2013

CHRISTOPHER DIESERU

LEEA, SNT LEVEL II MT, PT & UT

Qty

Description of Equipment SHACKLE

SWL

HI/105

Bow Safety Pin Shackle

17 t

LOCATION : RIG FLOOR


Particulars of defects found which are, or could, become a danger to persons or none Particulars of any repair, alteration to remedy defect or none

Wrong pin (Unfitted pin)

Remove from service Address of premises where Test / Examination was held:

(Not Fit for Use)


Name and address of equipment owner:

Transocean Support Services HIGHISLAND VII We hereby certify that on 19/01/2013 (date) defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Conducting Examination Name of Inspector: CHRISTOPHER DIESERU Conducting: Examination only

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

DEFECT / NON COMPLIANCE REPORT


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

90586 Identification Number

19/01/2013

CHRISTOPHER DIESERU

LEEA, SNT LEVEL II MT, PT & UT

Qty

Description of Equipment SHACKLE

SWL

S8

Bow Safety Pin Shackle

6.5 t

LOCATION : RIG FLOOR


Particulars of defects found which are, or could, become a danger to persons or none Particulars of any repair, alteration to remedy defect or none

Wrong pin

Remove from service Address of premises where Test / Examination was held:

(Not Fit for Use)


Name and address of equipment owner:

Transocean Support Services HIGHISLAND VII We hereby certify that on 19/01/2013 (date) defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Conducting Examination Name of Inspector: CHRISTOPHER DIESERU Conducting: Examination only

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

DEFECT / NON COMPLIANCE REPORT


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

90587 Identification Number

19/01/2013

CHRISTOPHER DIESERU

LEEA, SNT LEVEL II MT, PT & UT

Qty

Description of Equipment SHACKLE

SWL

KK 44

Bow Safety Pin Shackle

12 t

LOCATION : RIG FLOOR


Particulars of defects found which are, or could, become a danger to persons or none Particulars of any repair, alteration to remedy defect or none

Wrong pin

Remove from service Address of premises where Test / Examination was held:

(Not Fit for Use)


Name and address of equipment owner:

Transocean Support Services HIGHISLAND VII We hereby certify that on 19/01/2013 (date) defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Conducting Examination Name of Inspector: CHRISTOPHER DIESERU Conducting: Examination only

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

DEFECT / NON COMPLIANCE REPORT


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

90588 Identification Number

21/01/2013

CHRISTOPHER DIESERU

LEEA, SNT LEVEL II MT, PT & UT

Qty

Description of Equipment WIRE ROPE SLING

SWL

Sling ID: OSL/TSS 7087

19mm X 40ft X 2 Legged Sling c/w Master link one end other end soft eye.

6.4 t @ 0 0-45

LOCATION : CANTILEVER DECK


Particulars of defects found which are, or could, become a danger to persons or none Particulars of any repair, alteration to remedy defect or none

Severe soft eyes elongation Inner core exposure Deformed ferrule

Remove from service

(Not Fit for Use)


Name and address of equipment owner: Address of premises where Test / Examination was held:

Transocean Support Services HIGHISLAND VII We hereby certify that on 21/01/2013 (date) defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Conducting Examination Name of Inspector: CHRISTOPHER DIESERU Conducting: Examination only

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

DEFECT / NON COMPLIANCE REPORT


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

90589 Identification Number

21/01/2013

CHRISTOPHER DIESERU

LEEA, SNT LEVEL II MT, PT & UT

Qty

Description of Equipment WIRE ROPE SLING

SWL

Sling ID: 947711-0-3-1

32mm X 6.7m X Single leg Sling c/w Master link one end other end Shur Loc Hook

15 t

LOCATION : CANTILEVER DECK


Particulars of defects found which are, or could, become a danger to persons or none Particulars of any repair, alteration to remedy defect or none

Severe soft eyes elongation Inner core exposure Deformed ferrule

Remove from service

(Not Fit for Use)


Name and address of equipment owner: Address of premises where Test / Examination was held:

Transocean Support Services HIGHISLAND VII We hereby certify that on 21/01/2013 (date) defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Conducting Examination Name of Inspector: CHRISTOPHER DIESERU Conducting: Examination only

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

DEFECT / NON COMPLIANCE REPORT


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

90590 Identification Number

21/01/2013

CHRISTOPHER DIESERU

LEEA, SNT LEVEL II MT, PT & UT

Qty

Description of Equipment SHACKLE

SWL

TSS 2894

Bow Safety Pin Shackle

4.75 t

LOCATION : CANTILEVER DECK


Particulars of defects found which are, or could, become a danger to persons or none Particulars of any repair, alteration to remedy defect or none

Wrong pin

Remove from service Address of premises where Test / Examination was held:

(Not Fit for Use)


Name and address of equipment owner:

Transocean Support Services HIGHISLAND VII We hereby certify that on 21/01/2013 (date) defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Conducting Examination Name of Inspector: CHRISTOPHER DIESERU Conducting: Examination only

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

DEFECT / NON COMPLIANCE REPORT


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

90591 Identification Number

21/01/2013

CHRISTOPHER DIESERU

LEEA, SNT LEVEL II MT, PT & UT

Qty

Description of Equipment SHACKLE

SWL

TSS 3573

Bow Safety Pin Shackle

3.25 t

LOCATION : CANTILEVER DECK


Particulars of defects found which are, or could, become a danger to persons or none Particulars of any repair, alteration to remedy defect or none

Wrong Nut

Remove from service Address of premises where Test / Examination was held:

(Not Fit for Use)


Name and address of equipment owner:

Transocean Support Services HIGHISLAND VII We hereby certify that on 21/01/2013 (date) defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Conducting Examination Name of Inspector: CHRISTOPHER DIESERU Conducting: Examination only

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

DEFECT / NON COMPLIANCE REPORT


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

90592 Identification Number

21/01/2013

CHRISTOPHER DIESERU

LEEA, SNT LEVEL II MT, PT & UT

Qty

Description of Equipment WIRE ROPE SLING

SWL

Sling ID: 2654

1pc

19mm X 30ft X Single leg Sling c/w Soft eyes both ends

4.6 t

LOCATION : CANTILEVER DECK


Particulars of defects found which are, or could, become a danger to persons or none Particulars of any repair, alteration to remedy defect or none

Kink

Remove from service Address of premises where Test / Examination was held:

(Not Fit for Use)


Name and address of equipment owner:

Transocean Support Services HIGHISLAND VII We hereby certify that on 21/01/2013 (date) defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Conducting Examination Name of Inspector: CHRISTOPHER DIESERU Conducting: Examination only

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

DEFECT / NON COMPLIANCE REPORT


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

90593 Identification Number

21/01/2013

CHRISTOPHER DIESERU

LEEA, SNT LEVEL II MT, PT & UT

Qty

Description of Equipment WIRE ROPE SLING

SWL

Sling ID: 1390800-1-1

1pc

32mm X 17ft X Single leg Sling c/w Soft eyes both ends

15 t

LOCATION : CANTILEVER DECK


Particulars of defects found which are, or could, become a danger to persons or none Particulars of any repair, alteration to remedy defect or none

Permanent Bent

Remove from service Address of premises where Test / Examination was held:

(Not Fit for Use)


Name and address of equipment owner:

Transocean Support Services HIGHISLAND VII We hereby certify that on 21/01/2013 (date) defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Conducting Examination Name of Inspector: CHRISTOPHER DIESERU Conducting: Examination only

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

DEFECT / NON COMPLIANCE REPORT


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

90594 Identification Number

21/01/2013

CHRISTOPHER DIESERU

LEEA, SNT LEVEL II MT, PT & UT

Qty

Description of Equipment WIRE ROPE SLING

SWL

Sling ID: 1390800-1-2

1pc

32mm X 17ft X Single leg Sling c/w Soft eyes both ends

15 t

LOCATION : CANTILEVER DECK


Particulars of defects found which are, or could, become a danger to persons or none Particulars of any repair, alteration to remedy defect or none

Permanent Bent

Remove from service Address of premises where Test / Examination was held:

(Not Fit for Use)


Name and address of equipment owner:

Transocean Support Services HIGHISLAND VII We hereby certify that on 21/01/2013 (date) defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Conducting Examination Name of Inspector: CHRISTOPHER DIESERU Conducting: Examination only

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

DEFECT / NON COMPLIANCE REPORT


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

90595 Identification Number

22/01/2013

CHRISTOPHER DIESERU

LEEA, SNT LEVEL II MT, PT & UT

Qty

Description of Equipment AIR WINCH

SWL

AW 1

1pc

Air Winch

5000lbs

LOCATION : UNDER CANTILEVER DECK STBD SIDE


Particulars of defects found which are, or could, become a danger to persons or none Particulars of any repair, alteration to remedy defect or none

Faulty Brake system

Remove from service Address of premises where Test / Examination was held:

(Not Fit for Use)


Name and address of equipment owner:

Transocean Support Services HIGHISLAND VII We hereby certify that on 22/01/2013 (date) defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Conducting Examination Name of Inspector: CHRISTOPHER DIESERU Conducting: Examination only

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

DEFECT / NON COMPLIANCE REPORT


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

90596 Identification Number

22/01/2013

CHRISTOPHER DIESERU

LEEA, SNT LEVEL II MT, PT & UT

Qty

Description of Equipment AIR WINCH

SWL

MRT 02

1pc

Air Winch

5000lbs

LOCATION : UNDER CANTILEVER DECK


Particulars of defects found which are, or could, become a danger to persons or none Particulars of any repair, alteration to remedy defect or none

Faulty Brake system

Remove from service Address of premises where Test / Examination was held:

(Not Fit for Use)


Name and address of equipment owner:

Transocean Support Services HIGHISLAND VII We hereby certify that on 22/01/2013 (date) defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Conducting Examination Name of Inspector: CHRISTOPHER DIESERU Conducting: Examination only

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

DEFECT / NON COMPLIANCE REPORT


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

90597 Identification Number

22/01/2013

CHRISTOPHER DIESERU

LEEA, SNT LEVEL II MT, PT & UT

Qty

Description of Equipment AIR WINCH

SWL

MW 2520803

1pc

Air Winch

5000lbs

LOCATION : UNDER CANTILEVER DECK PORT SIDE


Particulars of defects found which are, or could, become a danger to persons or none Particulars of any repair, alteration to remedy defect or none

Faulty Brake system

Remove from service Address of premises where Test / Examination was held:

(Not Fit for Use)


Name and address of equipment owner:

Transocean Support Services HIGHISLAND VII We hereby certify that on 22/01/2013 (date) defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Conducting Examination Name of Inspector: CHRISTOPHER DIESERU Conducting: Examination only

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

DEFECT / NON COMPLIANCE REPORT


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

90598 Identification Number

22/01/2013

CHRISTOPHER DIESERU

LEEA, SNT LEVEL II MT, PT & UT

Qty

Description of Equipment MAN RIDER WINCH

SWL

090675

1pc

Man Rider Winch

150kg

LOCATION : UNDER CANTILEVER DECK PORT SIDE


Particulars of defects found which are, or could, become a danger to persons or none Particulars of any repair, alteration to remedy defect or none

Malfunctioning

Remove from service Address of premises where Test / Examination was held:

(Not Fit for Use)


Name and address of equipment owner:

Transocean Support Services HIGHISLAND VII We hereby certify that on 22/01/2013 (date) defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Conducting Examination Name of Inspector: CHRISTOPHER DIESERU Conducting: Examination only

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

DEFECT / NON COMPLIANCE REPORT


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

90599 Identification Number

22/01/2013

CHRISTOPHER DIESERU

LEEA, SNT LEVEL II MT, PT & UT

Qty

Description of Equipment AIR WINCH

SWL

AW 2

1pc

Air Winch

5000lbs

LOCATION : MAIN DECK STBD SIDE


Particulars of defects found which are, or could, become a danger to persons or none Particulars of any repair, alteration to remedy defect or none

Faulty Brake system

Remove from service Address of premises where Test / Examination was held:

(Not Fit for Use)


Name and address of equipment owner:

Transocean Support Services HIGHISLAND VII We hereby certify that on 22/01/2013 (date) defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Conducting Examination Name of Inspector: CHRISTOPHER DIESERU Conducting: Examination only

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

DEFECT / NON COMPLIANCE REPORT


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

90600 Identification Number

22/01/2013

CHRISTOPHER DIESERU

LEEA, SNT LEVEL II MT, PT & UT

Qty

Description of Equipment WIRE ROPE SLING

SWL

Sling ID: 50015685-1-1

1pc

16mm X 200ft X Single leg Sling c/w 7/8 Closed Spelter socket one end. Plain other end attached to Air Winch (S/N: AW 2)

4.1 t

LOCATION : MAIN DECK STBD SIDE


Particulars of defects found which are, or could, become a danger to persons or none Particulars of any repair, alteration to remedy defect or none

Severe Wire rope crusting

Remove from service Address of premises where Test / Examination was held:

(Not Fit for Use)


Name and address of equipment owner:

Transocean Support Services HIGHISLAND VII We hereby certify that on 22/01/2013 (date) defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Conducting Examination Name of Inspector: CHRISTOPHER DIESERU Conducting: Examination only

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

DEFECT / NON COMPLIANCE REPORT


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

90601 Identification Number

22/01/2013

CHRISTOPHER DIESERU

LEEA, SNT LEVEL II MT, PT & UT

Qty

Description of Equipment AIR WINCH

SWL

MW016564

1pc

Air Winch

5000lbs

LOCATION : BOW DECK


Particulars of defects found which are, or could, become a danger to persons or none Particulars of any repair, alteration to remedy defect or none

Faulty Brake system

Remove from service Address of premises where Test / Examination was held:

(Not Fit for Use)


Name and address of equipment owner:

Transocean Support Services HIGHISLAND VII We hereby certify that on 22/01/2013 (date) defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Conducting Examination Name of Inspector: CHRISTOPHER DIESERU Conducting: Examination only

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

DEFECT / NON COMPLIANCE REPORT


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

90602 Identification Number

22/01/2013

CHRISTOPHER DIESERU

LEEA, SNT LEVEL II MT, PT & UT

Qty

Description of Equipment WIRE ROPE SLING

SWL

Sling ID: ERNL-AOSR 105

1pc

19mm X 6m X Single leg Sling c/w Soft eyes both ends

4.62 t

LOCATION : MAIN DECK PORT SIDE


Particulars of defects found which are, or could, become a danger to persons or none Particulars of any repair, alteration to remedy defect or none

Permanent Bent

Remove from service Address of premises where Test / Examination was held:

(Not Fit for Use)


Name and address of equipment owner:

Transocean Support Services HIGHISLAND VII We hereby certify that on 22/01/2013 (date) defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Conducting Examination Name of Inspector: CHRISTOPHER DIESERU Conducting: Examination only

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

DEFECT / NON COMPLIANCE REPORT


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

90603 Identification Number

22/01/2013

CHRISTOPHER DIESERU

LEEA, SNT LEVEL II MT, PT & UT

Qty

Description of Equipment WIRE ROPE SLING

SWL

Sling ID: 5T/2039

1pc

38mm X 6.8m X Single leg Sling c/w Master link one end, Shur Loc Hook other end

22.33 t

LOCATION : MAIN DECK PORT SIDE


Particulars of defects found which are, or could, become a danger to persons or none Particulars of any repair, alteration to remedy defect or none

Wobbling Thimble

Remove from service Address of premises where Test / Examination was held:

(Not Fit for Use)


Name and address of equipment owner:

Transocean Support Services HIGHISLAND VII We hereby certify that on 22/01/2013 (date) defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Conducting Examination Name of Inspector: CHRISTOPHER DIESERU Conducting: Examination only

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

DEFECT / NON COMPLIANCE REPORT


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

90604 Identification Number

22/01/2013

CHRISTOPHER DIESERU

LEEA, SNT LEVEL II MT, PT & UT

Qty

Description of Equipment AIR WINCH

SWL

MWO 18604

1pc

Air Winch

5000lbs

LOCATION : RIG FLOOR PORT SIDE


Particulars of defects found which are, or could, become a danger to persons or none Particulars of any repair, alteration to remedy defect or none

Faulty Brake system

Remove from service Address of premises where Test / Examination was held:

(Not Fit for Use)


Name and address of equipment owner:

Transocean Support Services HIGHISLAND VII We hereby certify that on 22/01/2013 (date) defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Conducting Examination Name of Inspector: CHRISTOPHER DIESERU Conducting: Examination only

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

DEFECT / NON COMPLIANCE REPORT


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

90605 Identification Number

22/01/2013

CHRISTOPHER DIESERU

LEEA, SNT LEVEL II MT, PT & UT

Qty

Description of Equipment SHACKLE

SWL

S 15

Bow Safety Pin Shackle

35 t

LOCATION : MAIN DECK PORT SIDE


Particulars of defects found which are, or could, become a danger to persons or none Particulars of any repair, alteration to remedy defect or none

Wrong Nut

Remove from service Address of premises where Test / Examination was held:

(Not Fit for Use)


Name and address of equipment owner:

Transocean Support Services HIGHISLAND VII We hereby certify that on 22/01/2013 (date) defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Conducting Examination Name of Inspector: CHRISTOPHER DIESERU Conducting: Examination only

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

DEFECT / NON COMPLIANCE REPORT


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

90606 Identification Number

22/01/2013

CHRISTOPHER DIESERU

LEEA, SNT LEVEL II MT, PT & UT

Qty

Description of Equipment SHACKLE

SWL

124668-30

Bow Safety Pin Shackle

8.5 t

LOCATION : MAIN DECK PORT SIDE


Particulars of defects found which are, or could, become a danger to persons or none Particulars of any repair, alteration to remedy defect or none

Wrong Pin (Unfitted Pin)

Remove from service Address of premises where Test / Examination was held:

(Not Fit for Use)


Name and address of equipment owner:

Transocean Support Services HIGHISLAND VII We hereby certify that on 22/01/2013 (date) defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Conducting Examination Name of Inspector: CHRISTOPHER DIESERU Conducting: Examination only

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

DEFECT / NON COMPLIANCE REPORT


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

90607 Identification Number

22/01/2013

CHRISTOPHER DIESERU

LEEA, SNT LEVEL II MT, PT & UT

Qty

Description of Equipment SHACKLE

SWL

0502

Bow Safety Pin Shackle

8.5 t

LOCATION : MAIN DECK PORT SIDE


Particulars of defects found which are, or could, become a danger to persons or none Particulars of any repair, alteration to remedy defect or none

Wrong Nut

Remove from service Address of premises where Test / Examination was held:

(Not Fit for Use)


Name and address of equipment owner:

Transocean Support Services HIGHISLAND VII We hereby certify that on 22/01/2013 (date) defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Conducting Examination Name of Inspector: CHRISTOPHER DIESERU Conducting: Examination only

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

DEFECT / NON COMPLIANCE REPORT


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

90608 Identification Number

22/01/2013

CHRISTOPHER DIESERU

LEEA, SNT LEVEL II MT, PT & UT

Qty

Description of Equipment SHACKLE

SWL

V10

Bow Safety Pin Shackle

4.75 t

LOCATION : MAIN DECK PORT SIDE


Particulars of defects found which are, or could, become a danger to persons or none Particulars of any repair, alteration to remedy defect or none

Wrong Pin

Remove from service Address of premises where Test / Examination was held:

(Not Fit for Use)


Name and address of equipment owner:

Transocean Support Services HIGHISLAND VII We hereby certify that on 22/01/2013 (date) defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Conducting Examination Name of Inspector: CHRISTOPHER DIESERU Conducting: Examination only

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

DEFECT / NON COMPLIANCE REPORT


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

90609 Identification Number

22/01/2013

CHRISTOPHER DIESERU

LEEA, SNT LEVEL II MT, PT & UT

Qty

Description of Equipment SHACKLE

SWL

J2242

Bow Screw Pin Shackle

9.5 t

LOCATION : MAIN DECK PORT SIDE


Particulars of defects found which are, or could, become a danger to persons or none Particulars of any repair, alteration to remedy defect or none

Wrong Pin

Remove from service Address of premises where Test / Examination was held:

(Not Fit for Use)


Name and address of equipment owner:

Transocean Support Services HIGHISLAND VII We hereby certify that on 22/01/2013 (date) defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Conducting Examination Name of Inspector: CHRISTOPHER DIESERU Conducting: Examination only

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

DEFECT / NON COMPLIANCE REPORT


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

90610 Identification Number

23/01/2013

CHRISTOPHER DIESERU

LEEA, SNT LEVEL II MT, PT & UT

Qty

Description of Equipment CHAIN BLOCK

SWL

CB 01

Chain Block c/w 8mm X 3m Single Chain fall

2t

LOCATION : BOW DECK


Particulars of defects found which are, or could, become a danger to persons or none Particulars of any repair, alteration to remedy defect or none

No grade mark on load chain

Remove from service Address of premises where Test / Examination was held:

(Not Fit for Use)


Name and address of equipment owner:

Transocean Support Services HIGHISLAND VII We hereby certify that on 23/01/2013 (date) defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Conducting Examination Name of Inspector: CHRISTOPHER DIESERU Conducting: Examination only