KM26 Configuration Guide PDF
KM26 Configuration Guide PDF
CONFIGURATION GUIDE
K-TEK 18321 Swamp Road Prairieville, Louisiana 70769 USA Telephone: (1) 225-673-6100 Fax: (1) 225-673-2525
KM26-0202-1 Rev E (07-2005) For latest version of this configuration guide, visit www.ktekcorp.com.
NEW
Use the QuikShip chart below to select the model that best fits your application, then specify accessories (indicator type, transmitter, switches, etc) on the applicable QS drawing(s) that have been provided in the subsequent pages.
QuikShip #
QS1 QS2 QS3 QS4 QS5 QS6 QS7 QS8 QS9 QS10 QS11 QS12 QS13 QS14 QS15 QS16
Connection Size
2 150# RF WN Flange 2 150# RF WN Flange 2 150# RF WN Flange 2 150# RF WN Flange 2 300# RF WN Flange 2 300# RF WN Flange 2 300# RF WN Flange 2 300# RF WN Flange 1 MNPT Nipple 1 MNPT Nipple 1 MNPT Nipple 1 MNPT Nipple 1 MNPT Nipple 1 MNPT Nipple 1 MNPT Nipple 1 MNPT Nipple
Material Type
304SS 316SS 304SS 316SS 304SS 316SS 304SS 316SS 304SS 316SS 304SS 316SS 304SS 316SS 304SS 316SS
Page #
3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
Example: Application Requirements: Total level, Oil, Min SG of 0.6, Flange Process Connections, 150# / 300F operating pressure/temperature, customer requests 316SS KTEK Recommended QS Model: QS4 Very Important: QuikShip drawings are available in this document and on K-TEKs website (www.ktekcorp.com) and should be completed via fax (225-673-2525) or email ([email protected]) for immediate processing. 2
3-13/16" 3-5/8"
TOP VIEW
2-5/8"
3
10" 2" 150# RF SLIP ON FLANGE 1/2" NPT DRAIN PLUG SIDE VIEW 2" 150# RF BLIND FLANGE
ACCESSORIES: TRANSMITTER: _____ AT200 or _____AT600 (16 foot maximum ML on AT600) Check transmitter options (available for AT200 or AT600): _____ BOTTOM or _____ TOP CONNECTED ELECTRONIC HOUSING _____ FACTORY MUTUAL/CSA or ______ CENELEC APPROVAL Check additional transmitter options for AT200 only: _____ LCD INDICATOR _____ HART or _____ HONEYWELL DE or _____ FOUNDATION FIELDBUS
FRONT VIEW
SWITCH (SPECIFY QTY) _____ MS-30 (1 AMP, SPDT, NEMA 4X HOUSING) _____ MS-30/EX (1 AMP, SPDT, EXPLOSION PROOF HOUSING) _____ MS-40 (10 AMP, DPDT, NEMA 4X HOUSING) _____ MS-40/EX (10 AMP, DPDT, EXPLOSION PROOF HOUSING) _____ MS-41/S/F7/X (10 AMP, DPDT, NEMA 4X HOUSING) _____ PS-35 (PNEUMATIC; 15-100 PSIG SUPPLY, NEMA 4X HOUSING) _____ PS-45 (PNEUMATIC; 1-100 PSIG SUPPLY, NEMA 4X HOUSING)
PROCESS CONDITIONS: - LEVEL GAUGE PRESSURE RATINGS: 275 PSIG @ 100F, 235 PSIG @ 200F, 215 PSIG @ 300F (NOT RATED FOR CRYOGENIC TEMPERATURES) - MIN. SPECIFIC GRAVITY: 0.70 MATERIAL SPECIFICATIONS: - CHAMBER & FLANGES: 2" SCH 10 SA-312 TP 304 SS CHAMBER, SA-182 F304 SS RF FLANGES - FLOAT MATERIAL TYPE: 316 SS - STUDS: A193-B7, NUTS: A194 2H; BOTH CADMIUM PLATED, YELLOW DICHROMATE DIPPED - GASKET: 1/16" THICK, FLEXIBLE GRAPHITE WITH 316/316L SS INSERT - SCALE ASSEMBLY: 316 SS CHANNEL, RULER & CLAMPS
KM26QS1
3-13/16" 3-5/8"
TOP VIEW
2-5/8"
4
10" 2" 150# RF SLIP ON FLANGE 1/2" NPT DRAIN PLUG SIDE VIEW 2" 150# RF BLIND FLANGE
ACCESSORIES: TRANSMITTER: _____ AT200 or _____AT600 (16 foot maximum ML on AT600) Check transmitter options (available for AT200 or AT600): _____ BOTTOM or _____ TOP CONNECTED ELECTRONIC HOUSING _____ FACTORY MUTUAL/CSA or ______ CENELEC APPROVAL Check additional transmitter options for AT200 only: _____ LCD INDICATOR _____ HART or _____ HONEYWELL DE or _____ FOUNDATION FIELDBUS
FRONT VIEW
SWITCH (SPECIFY QTY) _____ MS-30 (1 AMP, SPDT, NEMA 4X HOUSING) _____ MS-30/EX (1 AMP, SPDT, EXPLOSION PROOF HOUSING) _____ MS-40 (10 AMP, DPDT, NEMA 4X HOUSING) _____ MS-40/EX (10 AMP, DPDT, EXPLOSION PROOF HOUSING) _____ MS-41/S/F7/X (10 AMP, DPDT, NEMA 4X HOUSING) _____ PS-35 (PNEUMATIC; 15-100 PSIG SUPPLY, NEMA 4X HOUSING) _____ PS-45 (PNEUMATIC; 1-100 PSIG SUPPLY, NEMA 4X HOUSING)
K-TEK LLC 18321 SWAMP ROAD PRAIRIEVILLE, LA 70769 USA
PROCESS CONDITIONS: - LEVEL GAUGE PRESSURE RATINGS: 275 PSIG @ 100F, 235 PSIG @ 200F, 215 PSIG @ 300F (NOT RATED FOR CRYOGENIC TEMPERATURES) - MIN. SPECIFIC GRAVITY: 0.70 MATERIAL SPECIFICATIONS: - CHAMBER & FLANGES: 2" SCH 10 SA-312 TP 316 SS CHAMBER, SA-182 F316 SS RF FLANGES - FLOAT MATERIAL TYPE: 316 SS - STUDS: A193-B7, NUTS: A194 2H; BOTH CADMIUM PLATED, YELLOW DICHROMATE DIPPED - GASKET: 1/16" THICK, FLEXIBLE GRAPHITE WITH 316/316L SS INSERT - SCALE ASSEMBLY: 316 SS CHANNEL, RULER & CLAMPS
4-1/16" 4-1/4"
TOP VIEW
MAX TEMP/PRESS. LIMITS: 275 PSIG @ 100F 235 PSIG @ 200F 215 PSIG @ 300F
2-5/8"
5
10" 2-1/2" 150# RF SLIP ON FLANGE 1/2" NPT DRAIN PLUG SIDE VIEW 2-1/2" 150# RF BLIND FLANGE
ACCESSORIES: TRANSMITTER: _____ AT200 or _____AT600 (16 foot maximum ML on AT600) Check transmitter options (available for AT200 or AT600): _____ BOTTOM or _____ TOP CONNECTED ELECTRONIC HOUSING _____ FACTORY MUTUAL/CSA or ______ CENELEC APPROVAL Check additional transmitter options for AT200 only: _____ LCD INDICATOR _____ HART or _____ HONEYWELL DE or _____ FOUNDATION FIELDBUS SWITCH (SPECIFY QTY) _____ MS-30 (1 AMP, SPDT, NEMA 4X HOUSING) _____ MS-30/EX (1 AMP, SPDT, EXPLOSION PROOF HOUSING) _____ MS-40 (10 AMP, DPDT, NEMA 4X HOUSING) _____ MS-40/EX (10 AMP, DPDT, EXPLOSION PROOF HOUSING) _____ MS-41/S/F7/X (10 AMP, DPDT, NEMA 4X HOUSING) _____ PS-35 (PNEUMATIC; 15-100 PSIG SUPPLY, NEMA 4X HOUSING) _____ PS-45 (PNEUMATIC; 1-100 PSIG SUPPLY, NEMA 4X HOUSING)
FRONT VIEW
PROCESS CONDITIONS: - LEVEL GAUGE PRESSURE RATINGS: 275 PSIG @ 100F, 235 PSIG @ 200F, 215 PSIG @ 300F (NOT RATED FOR CRYOGENIC TEMPERATURES) - MIN. SPECIFIC GRAVITY: 0.50 MATERIAL SPECIFICATIONS: - CHAMBER & FLANGES: 2-1/2" SCH 10 SA-312 TP 304 SS CHAMBER, SA-182 F304 SS RF FLANGES - FLOAT MATERIAL TYPE: GRADE 2 TITANIUM - STUDS: A193-B7, NUTS: A194 2H; BOTH CADMIUM PLATED, YELLOW DICHROMATE DIPPED - GASKET: 1/16" THICK, FLEXIBLE GRAPHITE WITH 316/316L SS INSERT - SCALE ASSEMBLY: 316 SS CHANNEL, RULER & CLAMPS
KM26QS3
4-1/16" 4-1/4"
TOP VIEW
2-5/8"
6
10" 2-1/2" 150# RF SLIP ON FLANGE 1/2" NPT DRAIN PLUG SIDE VIEW 2-1/2" 150# RF BLIND FLANGE
ACCESSORIES: TRANSMITTER: _____ AT200 or _____AT600 (16 foot maximum ML on AT600) Check transmitter options (available for AT200 or AT600): _____ BOTTOM or _____ TOP CONNECTED ELECTRONIC HOUSING _____ FACTORY MUTUAL/CSA or ______ CENELEC APPROVAL Check additional transmitter options for AT200 only: _____ LCD INDICATOR _____ HART or _____ HONEYWELL DE or _____ FOUNDATION FIELDBUS SWITCH (SPECIFY QTY) _____ MS-30 (1 AMP, SPDT, NEMA 4X HOUSING) _____ MS-30/EX (1 AMP, SPDT, EXPLOSION PROOF HOUSING) _____ MS-40 (10 AMP, DPDT, NEMA 4X HOUSING) _____ MS-40/EX (10 AMP, DPDT, EXPLOSION PROOF HOUSING) _____ MS-41/S/F7/X (10 AMP, DPDT, NEMA 4X HOUSING) _____ PS-35 (PNEUMATIC; 15-100 PSIG SUPPLY, NEMA 4X HOUSING) _____ PS-45 (PNEUMATIC; 1-100 PSIG SUPPLY, NEMA 4X HOUSING)
FRONT VIEW
PROCESS CONDITIONS : - LEVEL GAUGE PRESSURE RATINGS: 275 PSIG @ 100F, 235 PSIG @ 200F, 215 PSIG @ 300F (NOT RATED FOR CRYOGENIC TEMPERATURES) - MIN. SPECIFIC GRAVITY: 0.50 MATERIAL SPECIFICATIONS : - CHAMBER & FLANGES: 2-1/2" SCH 10 SA-312 TP 316 SS CHAMBER, SA-182 F316 SS RF FLANGES - FLOAT MATERIAL TYPE: GRADE 2 TITANIUM - STUDS: A193-B7, NUTS: A194 2H; BOTH CADMIUM PLATED, YELLOW DICHROMATE DIPPED - GASKET: 1/16" THICK, FLEXIBLE GRAPHITE WITH 316/316L SS INSERT - SCALE ASSEMBLY: 316 SS CHANNEL, RULER & CLAMPS
KM26QS4
4-1/16" 3-15/16"
TOP VIEW
2-7/8"
7
10" 2" 300# RF SLIP ON FLANGE 1/2" NPT DRAIN PLUG SIDE VIEW 2" 300# RF BLIND FLANGE
ACCESSORIES: TRANSMITTER : _____ AT200 or _____AT600 (16 foot maximum ML on AT600) Check transmitter options (available for AT200 or AT600): _____ BOTTOM or _____ TOP CONNECTED ELECTRONIC HOUSING _____ FACTORY MUTUAL/CSA or ______ CENELEC APPROVAL Check additional transmitter options for AT200 only: _____ LCD INDICATOR _____ HART or _____ HONEYWELL DE or _____ FOUNDATION FIELDBUS
FRONT VIEW
SWITCH (SPECIFY QTY) _____ MS-30 (1 AMP, SPDT, NEMA 4X HOUSING) _____ MS-30/EX (1 AMP, SPDT, EXPLOSION PROOF HOUSING) _____ MS-40 (10 AMP, DPDT, NEMA 4X HOUSING) _____ MS-40/EX (10 AMP, DPDT, EXPLOSION PROOF HOUSING) _____ MS-41/S/F7/X (10 AMP, DPDT, NEMA 4X HOUSING) _____ PS-35 (PNEUMATIC; 15-100 PSIG SUPPLY, NEMA 4X HOUSING) _____ PS-45 (PNEUMATIC; 1-100 PSIG SUPPLY, NEMA 4X HOUSING)
PROCESS CONDITIONS : - LEVEL GAUGE PRESSURE RATINGS: 720 PSIG @ 100F, 620 PSIG @ 200F, 560 PSIG @ 300F (NOT RATED FOR CRYOGENIC TEMPERATURES) - MIN. SPECIFIC GRAVITY: 0.80 MATERIAL SPECIFICATIONS : - CHAMBER & FLANGES: 2" SCH 10 SA-312 TP 304 SS CHAMBER, SA-182 F304 SS RF FLANGES - FLOAT MATERIAL TYPE: 316 SS - STUDS: A193-B7, NUTS: A194 2H; BOTH CADMIUM PLATED, YELLOW DICHROMATE DIPPED - GASKET: 1/16" THICK, FLEXIBLE GRAPHITE WITH 316/316L SS INSERT - SCALE ASSEMBLY: 316 SS CHANNEL, RULER & CLAMPS
KM26QS5
4-1/16" 3-15/16"
TOP VIEW
2-7/8"
8
10" 2" 300# RF SLIP ON FLANGE 1/2" NPT DRAIN PLUG SIDE VIEW 2" 300# RF BLIND FLANGE
ACCESSORIES: TRANSMITTER: _____ AT200 or _____AT600 (16 foot maximum ML on AT600) Check transmitter options (available for AT200 or AT600): _____ BOTTOM or _____ TOP CONNECTED ELECTRONIC HOUSING _____ FACTORY MUTUAL/CSA or ______ CENELEC APPROVAL Check additional transmitter options for AT200 only: _____ LCD INDICATOR _____ HART or _____ HONEYWELL DE or _____ FOUNDATION FIELDBUS
FRONT VIEW
SWITCH (SPECIFY QTY) _____ MS-30 (1 AMP, SPDT, NEMA 4X HOUSING) _____ MS-30/EX (1 AMP, SPDT, EXPLOSION PROOF HOUSING) _____ MS-40 (10 AMP, DPDT, NEMA 4X HOUSING) _____ MS-40/EX (10 AMP, DPDT, EXPLOSION PROOF HOUSING) _____ MS-41/S/F7/X (10 AMP, DPDT, NEMA 4X HOUSING) _____ PS-35 (PNEUMATIC; 15-100 PSIG SUPPLY, NEMA 4X HOUSING) _____ PS-45 (PNEUMATIC; 1-100 PSIG SUPPLY, NEMA 4X HOUSING)
PROCESS CONDITIONS: - LEVEL GAUGE PRESSURE RATINGS: 720 PSIG @ 100F, 620 PSIG @ 200F, 560 PSIG @ 300F (NOT RATED FOR CRYOGENIC TEMPERATURES) - MIN. SPECIFIC GRAVITY: 0.80 MATERIAL SPECIFICATIONS: - CHAMBER & FLANGES: 2" SCH 10 SA-312 TP 316 SS CHAMBER, SA-182 F316 SS RF FLANGES - FLOAT MATERIAL TYPE: 316 SS - STUDS: A193-B7, NUTS: A194 2H; BOTH CADMIUM PLATED, YELLOW DICHROMATE DIPPED - GASKET: 1/16" THICK, FLEXIBLE GRAPHITE WITH 316/316L SS INSERT - SCALE ASSEMBLY: 316 SS CHANNEL, RULER & CLAMPS
KM26QS6
4-5/16" 4-1/2"
TOP VIEW
MAX TEMP/PRESS. LIMITS: 720 PSIG @ 100F 620 PSIG @ 200F 560 PSIG @ 300F
2-7/8"
9
11" 2-1/2" 300# RF SLIP ON FLANGE 1/2" NPT DRAIN PLUG SIDE VIEW 2-1/2" 300# RF BLIND FLANGE
ACCESSORIES: TRANSMITTER: _____ AT200 or _____AT600 (16 foot maximum ML on AT600) Check transmitter options (available for AT200 or AT600): _____ BOTTOM or _____ TOP CONNECTED ELECTRONIC HOUSING _____ FACTORY MUTUAL/CSA or ______ CENELEC APPROVAL Check additional transmitter options for AT200 only: _____ LCD INDICATOR _____ HART or _____ HONEYWELL DE or _____ FOUNDATION FIELDBUS SWITCH (SPECIFY QTY) _____ MS-30 (1 AMP, SPDT, NEMA 4X HOUSING) _____ MS-30/EX (1 AMP, SPDT, EXPLOSION PROOF HOUSING) _____ MS-40 (10 AMP, DPDT, NEMA 4X HOUSING) _____ MS-40/EX (10 AMP, DPDT, EXPLOSION PROOF HOUSING) _____ MS-41/S/F7/X (10 AMP, DPDT, NEMA 4X HOUSING) _____ PS-35 (PNEUMATIC; 15-100 PSIG SUPPLY, NEMA 4X HOUSING) _____ PS-45 (PNEUMATIC; 1-100 PSIG SUPPLY, NEMA 4X HOUSING)
FRONT VIEW
PROCESS CONDITIONS: - LEVEL GAUGE PRESSURE RATINGS: 720 PSIG @ 100F, 620 PSIG @ 200F, 560 PSIG @ 300F (NOT RATED FOR CRYOGENIC TEMPERATURES) - MIN. SPECIFIC GRAVITY: 0.52 MATERIAL SPECIFICATIONS: - CHAMBER & FLANGES: 2-1/2" SCH 10 SA-312 TP 304 SS CHAMBER, SA-182 F304 SS RF FLANGES - FLOAT MATERIAL TYPE: GRADE 2 TITANIUM - STUDS: A193-B7, NUTS: A194 2H; BOTH CADMIUM PLATED, YELLOW DICHROMATE DIPPED - GASKET: 1/16" THICK, FLEXIBLE GRAPHITE WITH 316/316L SS INSERT - SCALE ASSEMBLY: 316 SS CHANNEL, RULER & CLAMPS
KM26QS7
4-5/16" 4-1/2"
TOP VIEW
2-7/8"
10
11" 2-1/2" 300# RF SLIP ON FLANGE 1/2" NPT DRAIN PLUG SIDE VIEW 2-1/2" 300# RF BLIND FLANGE
ACCESSORIES: TRANSMITTER: _____ AT200 or _____AT600 (16 foot maximum ML on AT600) Check transmitter options (available for AT200 or AT600): _____ BOTTOM or _____ TOP CONNECTED ELECTRONIC HOUSING _____ FACTORY MUTUAL/CSA or ______ CENELEC APPROVAL Check additional transmitter options for AT200 only: _____ LCD INDICATOR _____ HART or _____ HONEYWELL DE or _____ FOUNDATION FIELDBUS SWITCH (SPECIFY QTY) _____ MS-30 (1 AMP, SPDT, NEMA 4X HOUSING) _____ MS-30/EX (1 AMP, SPDT, EXPLOSION PROOF HOUSING) _____ MS-40 (10 AMP, DPDT, NEMA 4X HOUSING) _____ MS-40/EX (10 AMP, DPDT, EXPLOSION PROOF HOUSING) _____ MS-41/S/F7/X (10 AMP, DPDT, NEMA 4X HOUSING) _____ PS-35 (PNEUMATIC; 15-100 PSIG SUPPLY, NEMA 4X HOUSING) _____ PS-45 (PNEUMATIC; 1-100 PSIG SUPPLY, NEMA 4X HOUSING)
K-TEK LLC 18321 SWAMP ROAD PRAIRIEVILLE, LA 70769 USA
FRONT VIEW
PROCESS CONDITIONS: - LEVEL GAUGE PRESSURE RATINGS: 720 PSIG @ 100F, 620 PSIG @ 200F, 560 PSIG @ 300F (NOT RATED FOR CRYOGENIC TEMPERATURES) - MIN. SPECIFIC GRAVITY: 0.52 MATERIAL SPECIFICATIONS: - CHAMBER & FLANGES: 2-1/2" SCH 10 SA-312 TP 316 SS CHAMBER, SA-182 F316 SS RF FLANGES - FLOAT MATERIAL TYPE: GRADE 2 TITANIUM - STUDS: A193-B7, NUTS: A194 2H; BOTH CADMIUM PLATED, YELLOW DICHROMATE DIPPED - GASKET: 1/16" THICK, FLEXIBLE GRAPHITE WITH 316/316L SS INSERT - SCALE ASSEMBLY: 316 SS CHANNEL, RULER & CLAMPS
4-3/16" 3-5/8"
TOP VIEW
MAX TEMP/PRESS. LIMITS: 275 PSIG @ 100F 235 PSIG @ 200F 215 PSIG @ 300F
3"
11
10" 2" 150# RF SLIP ON FLANGE 1/2" NPT DRAIN PLUG SIDE VIEW 2" 150# RF BLIND FLANGE
ACCESSORIES: TRANSMITTER: _____ AT200 or _____AT600 (16 foot maximum ML on AT600) Check transmitter options (available for AT200 or AT600): _____ BOTTOM or _____ TOP CONNECTED ELECTRONIC HOUSING _____ FACTORY MUTUAL/CSA or ______ CENELEC APPROVAL Check additional transmitter options for AT200 only: _____ LCD INDICATOR _____ HART or _____ HONEYWELL DE or _____ FOUNDATION FIELDBUS
FRONT VIEW
SWITCH (SPECIFY QTY) _____ MS-30 (1 AMP, SPDT, NEMA 4X HOUSING) _____ MS-30/EX (1 AMP, SPDT, EXPLOSION PROOF HOUSING) _____ MS-40 (10 AMP, DPDT, NEMA 4X HOUSING) _____ MS-40/EX (10 AMP, DPDT, EXPLOSION PROOF HOUSING) _____ MS-41/S/F7/X (10 AMP, DPDT, NEMA 4X HOUSING) _____ PS-35 (PNEUMATIC; 15-100 PSIG SUPPLY, NEMA 4X HOUSING) _____ PS-45 (PNEUMATIC; 1-100 PSIG SUPPLY, NEMA 4X HOUSING)
PROCESS CONDITIONS: - LEVEL GAUGE PRESSURE RATINGS: 275 PSIG @ 100F, 235 PSIG @ 200F, 215 PSIG @ 300F (NOT RATED FOR CRYOGENIC TEMPERATURES) - MIN. SPECIFIC GRAVITY: 0.70 MATERIAL SPECIFICATIONS: - CHAMBER, NIPPLES & FLANGES: 2" SCH 10 SA-312 TP 304 SS CHAMBER & SCH 40 NIPPLES, SA-182 F304 SS RF FLANGES - FLOAT MATERIAL TYPE: 316 SS - STUDS: A193-B7, NUTS: A194 2H; BOTH CADMIUM PLATED, YELLOW DICHROMATE DIPPED - GASKET: 1/16" THICK, FLEXIBLE GRAPHITE WITH 316/316L SS INSERT - SCALE ASSEMBLY: 316 SS CHANNEL, RULER & CLAMPS
KM26QS9
4-3/16" 3-5/8"
TOP VIEW
3"
12
10" 2" 150# RF SLIP ON FLANGE 1/2" NPT DRAIN PLUG SIDE VIEW 2" 150# RF BLIND FLANGE
ACCESSORIES: TRANSMITTER: _____ AT200 or _____AT600 (16 foot maximum ML on AT600) Check transmitter options (available for AT200 or AT600): _____ BOTTOM or _____ TOP CONNECTED ELECTRONIC HOUSING _____ FACTORY MUTUAL/CSA or ______ CENELEC APPROVAL Check additional transmitter options for AT200 only: _____ LCD INDICATOR _____ HART or _____ HONEYWELL DE or _____ FOUNDATION FIELDBUS
FRONT VIEW
SWITCH (SPECIFY QTY) _____ MS-30 (1 AMP, SPDT, NEMA 4X HOUSING) _____ MS-30/EX (1 AMP, SPDT, EXPLOSION PROOF HOUSING) _____ MS-40 (10 AMP, DPDT, NEMA 4X HOUSING) _____ MS-40/EX (10 AMP, DPDT, EXPLOSION PROOF HOUSING) _____ MS-41/S/F7/X (10 AMP, DPDT, NEMA 4X HOUSING) _____ PS-35 (PNEUMATIC; 15-100 PSIG SUPPLY, NEMA 4X HOUSING) _____ PS-45 (PNEUMATIC; 1-100 PSIG SUPPLY, NEMA 4X HOUSING)
PROCESS CONDITIONS: - LEVEL GAUGE PRESSURE RATINGS: 275 PSIG @ 100F, 235 PSIG @ 200F, 215 PSIG @ 300F (NOT RATED FOR CRYOGENIC TEMPERATURES) - MIN. SPECIFIC GRAVITY: 0.70 MATERIAL SPECIFICATIONS: - CHAMBER, NIPPLES & FLANGES: 2" SCH 10 SA-312 TP 316 SS CHAMBER & SCH 40 NIPPLES, SA-182 F316 SS RF FLANGES - FLOAT MATERIAL TYPE: 316 SS - STUDS: A193-B7, NUTS: A194 2H; BOTH CADMIUM PLATED, YELLOW DICHROMATE DIPPED - GASKET: 1/16" THICK, FLEXIBLE GRAPHITE WITH 316/316L SS INSERT - SCALE ASSEMBLY: 316 SS CHANNEL, RULER & CLAMPS
KM26QS10
4-7/16" 4-1/4"
TOP VIEW
MAX TEMP/PRESS. LIMITS: 275 PSIG @ 100F 235 PSIG @ 200F 215 PSIG @ 300F
3"
13
10" 2-1/2" 150# RF SLIP ON FLANGE 1/2" NPT DRAIN PLUG SIDE VIEW 2-1/2" 150# RF BLIND FLANGE
ACCESSORIES: TRANSMITTER: _____ AT200 or _____AT600 (16 foot maximum ML on AT600) Check transmitter options (available for AT200 or AT600): _____ BOTTOM or _____ TOP CONNECTED ELECTRONIC HOUSING _____ FACTORY MUTUAL/CSA or ______ CENELEC APPROVAL Check additional transmitter options for AT200 only: _____ LCD INDICATOR _____ HART or _____ HONEYWELL DE or _____ FOUNDATION FIELDBUS SWITCH (SPECIFY QTY) _____ MS-30 (1 AMP, SPDT, NEMA 4X HOUSING) _____ MS-30/EX (1 AMP, SPDT, EXPLOSION PROOF HOUSING) _____ MS-40 (10 AMP, DPDT, NEMA 4X HOUSING) _____ MS-40/EX (10 AMP, DPDT, EXPLOSION PROOF HOUSING) _____ MS-41/S/F7/X (10 AMP, DPDT, NEMA 4X HOUSING) _____ PS-35 (PNEUMATIC; 15-100 PSIG SUPPLY, NEMA 4X HOUSING) _____ PS-45 (PNEUMATIC; 1-100 PSIG SUPPLY, NEMA 4X HOUSING)
FRONT VIEW
PROCESS CONDITIONS: - LEVEL GAUGE PRESSURE RATINGS: 275 PSIG @ 100F, 235 PSIG @ 200F, 215 PSIG @ 300F (NOT RATED FOR CRYOGENIC TEMPERATURES) - MIN. SPECIFIC GRAVITY: 0.50 MATERIAL SPECIFICATIONS: - CHAMBER, NIPPLES & FLANGES: 2-1/2" SCH 10 SA-312 TP 304 SS CHAMBER & SCH 40 NIPPLES, SA-182 F304 SS RF FLANGES - FLOAT MATERIAL TYPE: GRADE 2 TITANIUM - STUDS: A193-B7, NUTS: A194 2H; BOTH CADMIUM PLATED, YELLOW DICHROMATE DIPPED - GASKET: 1/16" THICK, FLEXIBLE GRAPHITE WITH 316/316L SS INSERT - SCALE ASSEMBLY: 316 SS CHANNEL, RULER & CLAMPS
KM26QS11
4-7/16" 4-1/4"
TOP VIEW
3"
14
1" SCH 40 MNPT NIPPLE 10" 2-1/2" 150# RF SLIP ON FLANGE 1/2" NPT DRAIN PLUG SIDE VIEW 2-1/2" 150# RF BLIND FLANGE
ACCESSORIES: TRANSMITTER: _____ AT200 or _____AT600 (16 foot maximum ML on AT600) Check transmitter options (available for AT200 or AT600): _____ BOTTOM or _____ TOP CONNECTED ELECTRONIC HOUSING _____ FACTORY MUTUAL/CSA or ______ CENELEC APPROVAL Check additional transmitter options for AT200 only: _____ LCD INDICATOR _____ HART or _____ HONEYWELL DE or _____ FOUNDATION FIELDBUS SWITCH (SPECIFY QTY) _____ MS-30 (1 AMP, SPDT, NEMA 4X HOUSING) _____ MS-30/EX (1 AMP, SPDT, EXPLOSION PROOF HOUSING) _____ MS-40 (10 AMP, DPDT, NEMA 4X HOUSING) _____ MS-40/EX (10 AMP, DPDT, EXPLOSION PROOF HOUSING) _____ MS-41/S/F7/X (10 AMP, DPDT, NEMA 4X HOUSING) _____ PS-35 (PNEUMATIC; 15-100 PSIG SUPPLY, NEMA 4X HOUSING) _____ PS-45 (PNEUMATIC; 1-100 PSIG SUPPLY, NEMA 4X HOUSING)
FRONT VIEW
PROCESS CONDITIONS: - LEVEL GAUGE PRESSURE RATINGS: 275 PSIG @ 100F, 235 PSIG @ 200F, 215 PSIG @ 300F (NOT RATED FOR CRYOGENIC TEMPERATURES) - MIN. SPECIFIC GRAVITY: 0.50 MATERIAL SPECIFICATIONS: - CHAMBER, NIPPLES & FLANGES: 2-1/2" SCH 10 SA-312 TP 316 SS CHAMBER & SCH 40 NIPPLES, SA-182 F316 SS RF FLANGES - FLOAT MATERIAL TYPE: GRADE 2 TITANIUM - STUDS: A193-B7, NUTS: A194 2H; BOTH CADMIUM PLATED, YELLOW DICHROMATE DIPPED - GASKET: 1/16" THICK, FLEXIBLE GRAPHITE WITH 316/316L SS INSERT - SCALE ASSEMBLY: 316 SS CHANNEL, RULER & CLAMPS
KM26QS12
4-3/16" 3-15/16"
TOP VIEW
MAX TEMP/PRESS. LIMITS: 720 PSIG @ 100F 620 PSIG @ 200F 560 PSIG @ 300F
3"
15
10" 2" 300# RF SLIP ON FLANGE 1/2" NPT DRAIN PLUG SIDE VIEW 2" 300# RF BLIND FLANGE
ACCESSORIES: TRANSMITTER: _____ AT200 or _____AT600 (16 foot maximum ML on AT600) Check transmitter options (available for AT200 or AT600): _____ BOTTOM or _____ TOP CONNECTED ELECTRONIC HOUSING _____ FACTORY MUTUAL/CSA or ______ CENELEC APPROVAL Check additional transmitter options for AT200 only: _____ LCD INDICATOR _____ HART or _____ HONEYWELL DE or _____ FOUNDATION FIELDBUS
FRONT VIEW
SWITCH (SPECIFY QTY) _____ MS-30 (1 AMP, SPDT, NEMA 4X HOUSING) _____ MS-30/EX (1 AMP, SPDT, EXPLOSION PROOF HOUSING) _____ MS-40 (10 AMP, DPDT, NEMA 4X HOUSING) _____ MS-40/EX (10 AMP, DPDT, EXPLOSION PROOF HOUSING) _____ MS-41/S/F7/X (10 AMP, DPDT, NEMA 4X HOUSING) _____ PS-35 (PNEUMATIC; 15-100 PSIG SUPPLY, NEMA 4X HOUSING) _____ PS-45 (PNEUMATIC; 1-100 PSIG SUPPLY, NEMA 4X HOUSING)
K-TEK LLC 18321 SWAMP ROAD PRAIRIEVILLE, LA 70769 USA
PROCESS CONDITIONS: - LEVEL GAUGE PRESSURE RATINGS: 720 PSIG @ 100F, 620 PSIG @ 200F, 560 PSIG @ 300F (NOT RATED FOR CRYOGENIC TEMPERATURES) - MIN. SPECIFIC GRAVITY: 0.80 MATERIAL SPECIFICATIONS: - CHAMBER, NIPPLES & FLANGES: 2" SCH 10 SA-312 TP 304 SS CHAMBER & SCH 40 NIPPLES, SA-182 F304 SS RF FLANGES - FLOAT MATERIAL TYPE: 316 SS - STUDS: A193-B7, NUTS: A194 2H; BOTH CADMIUM PLATED, YELLOW DICHROMATE DIPPED - GASKET: 1/16" THICK, FLEXIBLE GRAPHITE WITH 316/316L SS INSERT - SCALE ASSEMBLY: 316 SS CHANNEL, RULER & CLAMPS
4-3/16" 3-15/16"
TOP VIEW
3"
16
10" 2" 300# RF SLIP ON FLANGE 1/2" NPT DRAIN PLUG SIDE VIEW 2" 300# RF BLIND FLANGE
ACCESSORIES: TRANSMITTER: _____ AT200 or _____AT600 (16 foot maximum ML on AT600) Check transmitter options (available for AT200 or AT600): _____ BOTTOM or _____ TOP CONNECTED ELECTRONIC HOUSING _____ FACTORY MUTUAL/CSA or ______ CENELEC APPROVAL Check additional transmitter options for AT200 only: _____ LCD INDICATOR _____ HART or _____ HONEYWELL DE or _____ FOUNDATION FIELDBUS
FRONT VIEW
SWITCH (SPECIFY QTY) _____ MS-30 (1 AMP, SPDT, NEMA 4X HOUSING) _____ MS-30/EX (1 AMP, SPDT, EXPLOSION PROOF HOUSING) _____ MS-40 (10 AMP, DPDT, NEMA 4X HOUSING) _____ MS-40/EX (10 AMP, DPDT, EXPLOSION PROOF HOUSING) _____ MS-41/S/F7/X (10 AMP, DPDT, NEMA 4X HOUSING) _____ PS-35 (PNEUMATIC; 15-100 PSIG SUPPLY, NEMA 4X HOUSING) _____ PS-45 (PNEUMATIC; 1-100 PSIG SUPPLY, NEMA 4X HOUSING)
K-TEK LLC 18321 SWAMP ROAD PRAIRIEVILLE, LA 70769 USA
PROCESS CONDITIONS : - LEVEL GAUGE PRESSURE RATINGS: 720 PSIG @ 100F, 620 PSIG @ 200F, 560 PSIG @ 300F (NOT RATED FOR CRYOGENIC TEMPERATURES) - MIN. SPECIFIC GRAVITY: 0.80 MATERIAL SPECIFICATIONS : - CHAMBER, NIPPLES & FLANGES: 2" SCH 10 SA-312 TP 316 SS CHAMBER & SCH 40 NIPPLES, SA-182 F316 SS RF FLANGES - FLOAT MATERIAL TYPE: 316 SS - STUDS: A193-B7, NUTS: A194 2H; BOTH CADMIUM PLATED, YELLOW DICHROMATE DIPPED - GASKET: 1/16" THICK, FLEXIBLE GRAPHITE WITH 316/316L SS INSERT - SCALE ASSEMBLY: 316 SS CHANNEL, RULER & CLAMPS
4-7/16" 4-1/2"
TOP VIEW
3"
17
11" 2-1/2" 300# RF SLIP ON FLANGE 1/2" NPT DRAIN PLUG SIDE VIEW 2-1/2" 300# RF BLIND FLANGE
ACCESSORIES: TRANSMITTER: _____ AT200 or _____AT600 (16 foot maximum ML on AT600) Check transmitter options (available for AT200 or AT600): _____ BOTTOM or _____ TOP CONNECTED ELECTRONIC HOUSING _____ FACTORY MUTUAL/CSA or ______ CENELEC APPROVAL Check additional transmitter options for AT200 only: _____ LCD INDICATOR _____ HART or _____ HONEYWELL DE or _____ FOUNDATION FIELDBUS SWITCH (SPECIFY QTY) _____ MS-30 (1 AMP, SPDT, NEMA 4X HOUSING) _____ MS-30/EX (1 AMP, SPDT, EXPLOSION PROOF HOUSING) _____ MS-40 (10 AMP, DPDT, NEMA 4X HOUSING) _____ MS-40/EX (10 AMP, DPDT, EXPLOSION PROOF HOUSING) _____ MS-41/S/F7/X (10 AMP, DPDT, NEMA 4X HOUSING) _____ PS-35 (PNEUMATIC; 15-100 PSIG SUPPLY, NEMA 4X HOUSING) _____ PS-45 (PNEUMATIC; 1-100 PSIG SUPPLY, NEMA 4X HOUSING)
K-TEK LLC 18321 SWAMP ROAD PRAIRIEVILLE, LA 70769 USA
FRONT VIEW
PROCESS CONDITIONS: - LEVEL GAUGE PRESSURE RATINGS: 720 PSIG @ 100F, 620 PSIG @ 200F, 560 PSIG @ 300F (NOT RATED FOR CRYOGENIC TEMPERATURES) - MIN. SPECIFIC GRAVITY: 0.52 MATERIAL SPECIFICATIONS: - CHAMBER, NIPPLES & FLANGES: 2-1/2" SCH 10 SA-312 TP 304 SS CHAMBER & SCH 40 NIPPLES, SA-182 F304 SS RF FLANGES - FLOAT MATERIAL TYPE: GRADE 2 TITANIUM - STUDS: A193-B7, NUTS: A194 2H; BOTH CADMIUM PLATED, YELLOW DICHROMATE DIPPED - GASKET: 1/16" THICK, FLEXIBLE GRAPHITE WITH 316/316L SS INSERT - SCALE ASSEMBLY: 316 SS CHANNEL, RULER & CLAMPS
4-7/16" 4-1/2"
TOP VIEW
18
11" 2-1/2" 300# RF SLIP ON FLANGE 1/2" NPT DRAIN PLUG SIDE VIEW 2-1/2" 300# RF BLIND FLANGE
ACCESSORIES: TRANSMITTER: _____ AT200 or _____AT600 (16 foot maximum ML on AT600) Check transmitter options (available for AT200 or AT600): _____ BOTTOM or _____ TOP CONNECTED ELECTRONIC HOUSING _____ FACTORY MUTUAL/CSA or ______ CENELEC APPROVAL Check additional transmitter options for AT200 only: _____ LCD INDICATOR _____ HART or _____ HONEYWELL DE or _____ FOUNDATION FIELDBUS SWITCH (SPECIFY QTY) _____ MS-30 (1 AMP, SPDT, NEMA 4X HOUSING) _____ MS-30/EX (1 AMP, SPDT, EXPLOSION PROOF HOUSING) _____ MS-40 (10 AMP, DPDT, NEMA 4X HOUSING) _____ MS-40/EX (10 AMP, DPDT, EXPLOSION PROOF HOUSING) _____ MS-41/S/F7/X (10 AMP, DPDT, NEMA 4X HOUSING) _____ PS-35 (PNEUMATIC; 15-100 PSIG SUPPLY, NEMA 4X HOUSING) _____ PS-45 (PNEUMATIC; 1-100 PSIG SUPPLY, NEMA 4X HOUSING)
K-TEK LLC 18321 SWAMP ROAD PRAIRIEVILLE, LA 70769 USA
FRONT VIEW
PROCESS CONDITIONS : - LEVEL GAUGE PRESSURE RATINGS: 720 PSIG @ 100F, 620 PSIG @ 200F, 560 PSIG @ 300F (NOT RATED FOR CRYOGENIC TEMPERATURES) - MIN. SPECIFIC GRAVITY: 0.52 MATERIAL SPECIFICATIONS : - CHAMBER, NIPPLES & FLANGES: 2-1/2" SCH 10 SA-312 TP 316 SS CHAMBER & SCH 40 NIPPLES, SA-182 F316 SS RF FLANGES - FLOAT MATERIAL TYPE: GRADE 2 TITANIUM - STUDS: A193-B7, NUTS: A194 2H; BOTH CADMIUM PLATED, YELLOW DICHROMATE DIPPED - GASKET: 1/16" THICK, FLEXIBLE GRAPHITE WITH 316/316L SS INSERT - SCALE ASSEMBLY: 316 SS CHANNEL, RULER & CLAMPS
/b
Chamber Material
SS1 SS4 SS6 SS7 SS9 HSC HSB TI PP PVD PVC CPV EPF VEF TN4 TN6 HL4 HL6 TF4 TF6 A20 IN600 IN625 IN800 IN825 ALU ZI2
Notes:
1 2 3 4 5 6
To minimize friction for optimal float travel - max. temp = 425F (218C). For Increased Corrosion Resistance - max. temp = 300F (149C). Maximum measuring length is 18 feet (5.48 meters). Tefzel or Halar coated units must not have any FNPT, Vent or Drain options. Maximum measuring length 14 feet (4.27 meters). Maximum measuring length 13 feet (3.96 meters).
/c
Note:
Chamber Configuration1,2 (Select code from Table 1 on pages 21 & 22) (example /W2FEFEB2)
1
If more than 2 process connections are required add the code for each in the chamber configuration code (example /W2FEFEFEB2 or /W2(3)FEB2 for 3 process connections). 2 CST: Carbon Steel and DUP: Duplex Stainless Steel are available as KM26T stilling wells and KM26 flange type materials.
/d
Connection Size / Rating1,2 - (Select code from Table 2 on page 26) (example /SR21 )
1 Note: Flange sizes are available in ASME, DIN, HG , Gost and customer specified sizes. Consult factory for special requirements. 2 CST: Carbon Steel and DUP: Duplex Stainless Steel are available as KM26T stilling wells and KM26 flange type materials.
/e
Indicator Type
S1P S1G S2G M1P M2P M1G M2G CM1A CM2A CM1B CM2B CM1C CM2C X Fluorescent Shuttle w/ Permanently Sealed Lexan Tube (200F/93C max)1 Fluorescent Shuttle w/ Hermetically Sealed Glass Tube (350F/176C max)1 High Temp (Red) Shuttle w/ Hermetically Sealed Glass Tube (1000F/538C max)1 Yellow/Black MBG w/ Permanently Sealed Lexan Tube (200F/93C max)2 Red/White MBG w/ Permanently Sealed Lexan Tube (200F/93C max)2 Yellow/Black MBG w/ Hermetically Sealed Glass Tube (650F/343C max)3 Red/White MBG w/ Hermetically Sealed Glass Tube (650F/343C max)3 Yellow/Black MBG w/ Lexan Frost Extension for -100F/-73C min (2" thick insulation)4 Red/White MBG w/ Lexan Frost Extension for -100F/-73C min (2" thick insulation)4 Yellow/Black MBG w/ Lexan Frost Extension for -200F/-129C min (3" thick insulation)4 Red/White MBG w/ Lexan Frost Extension for -200F/-129C min (3" thick insulation)4 Yellow/Black MBG w/ Lexan Frost Extension for -320F/-195C min (4" thick insulation)4 Red/White MBG w/ Lexan Frost Extension for -320F/-195C (4" thick insulation)4 None
Notes:
1 2
Not available when a transmitter is used for total & interface level combined. Add H to the indicator type to include insulation pad behind the indicator and raise the maximum temperature to 300F / 149C. 3 Add HS to the indicator type to include insulation pad and TEMPKOAT behind the indicator and raise the maximum temperature to 1000F / 538C. 4 Cryogenic unit indicator types are NOT field accessible.
19
No indicator housing (must select X for Indicator Type on previous page) SS housing; no scale SS housing; SS scale marked in ft / inches w/ 1/2" divisions (from 0 to 48 ft. standard3) SS housing; SS scale marked in meters/centimeters w/ 1 cm divisions 1 SS housing; SS scale marked in running inches w/ 1/2" divisions 2 SS housing; SS scale marked in running inches w/ 1/8" divisions 2 SS housing; custom SS scale (%, gallons, liters, etc.) SS housing; custom plastic scale (%, gallons, liters, etc.) 200F (93C) max with no insulation SS housing; dual scale; specify types
Standard rulers begin with 0 cm but can be specified from 100 cm to 10 meters. Standard rulers begin with 0 inches but can be specified from: 1/2 divisions: -48 to 216 OR 1/8 divisions: -48 to 144 3 Custom rulers available (Consult Factory - Choose /F or /G).
/g
Other Options
IH1 IH1D IH2 IH2D IH3 IH3D IL1 IL2 IL3 TT1 SJ ET1xx ET2x ET3x IV DV VV RD G GR S High Temp. Insulation; Float Chamber Only; 1/2" thick; 250F (121C) max2 High Temp. Insulation; Float Chamber & Vent / Drain Flanges; 1/2" thick; 250F (121C) max2 High Temp. Insulation; Float Chamber Only; 1" thick; 500F (260C) max2 High Temp. Insulation; Float Chamber & Vent / Drain Flanges; 1" thick; 500F (260C) max2 High Temp. Insulation; Float Chamber Only; 2" thick; 900F (482C) max1,2 High Temp. Insulation; Float Chamber & Vent / Drain Flanges; 2" thick; 900F (482C) max1,2 Cryogenic Insulation; 2" thick; single layer; -100F (-73C) minimum Cryogenic Insulation; 3" thick; double layer; -200F (-129C) minimum Cryogenic Insulation; 4" thick; double layer; -320F (-196C) minimum Steam Trace Tubing Steam / Water Jacket Electric Tracing; Class I, Div. 2, Gp BCD; 221F max (105C); fixed setpoint control3 Electric Tracing; Class I, Div. 2, Gp BCD; 400F max (204C); adjustable setpoint control3 Electric Tracing; Class I, Div. 1, Gp CD; 800F max (427C); adjustable setpoint control3 Isolation Valve (Specify valve manufacturer and model) Drain Valve (Specify valve manufacturer and model) Vent Valve (Specify valve manufacturer and model) Switch Mount Rod (High Temperature option for KM26 Switches) (Consult data sheet for temperature specifics.) Gussets on process connections Oversized chamber with guide rods for flashing Special (Consult factory)
Notes:
1. Insulation is 1 thick when a level transmitter and / or level switch is used regardless of maximum temperature. 2. K-TEK recommends chamber insulation for personnel safety. 3. Specify power supply 1) 110, 2) 220, 3) 277 OR 4) 440 VAC) (ex. ET21= ET2 with 110VAC power supply). For ET1xx series only, specify setpoint A) 35, B) 45, C) 60, D) 90 or E) 185F (1.7, 7.2, 15.6, 32.2, or 85C) (ex. ET11A = ET1 with 110VAC power supply and a setpoint of 35F)
/h /i
B B
Measuring Length
(specify in inches or mm, only if different than the center to center dimensions)
FACE FACE ML TO ML TO FACE FACE
IMPORTANT NOTE: The information above is provided for the customer to indicate specific requirements. Only those requirements need to be specified. Other sizing & ratings not specified will be selected by the factory based on standard design & manufacturing practices using temperature, pressure & specific gravity data.
A A
20
CHAMBER CONFIGURATION
Table 1 - Code Options / Definitions
B0 B1 B2 B3 B4 B5 B6 B7 B8 B9 B10 C0 C0L C0E C1 C1L C2 D0 D1 D2 D3 D4 D5 D6 D7 D8 D9 D10 FE F0 F0E F1 F2 F3E F3 F4 GE G G1 G3E G4 H0 H1 H2 H3 Blind Flange, with Float Stop Spring and Matching Slip-On Flange B0 with FNPT (see Note 2); 1/2 FNPT standard B0 with Plug (see Note 5); 1/2 Standard B0 with Socket Weld Coupling B0 with FNPT Coupling B0 with Nipple, for Socket Welding (Flat) B0 with Nipple, for Butt Welding (37.5 bevel) B0 with Nipple, MNPT B0 with Top Mount Indicator B0 with Reducing Spool Piece and Flange (see Note 7) B0 with Socket Weld Bore (see Note 3); 1/2 SW standard FNPT Coupling Sock-o-let (Min. SCH 40 Chamber) FNPT Coupling Connected via Extruded Outlet (See Note 4) Socket Weld Coupling Thread-o-let (Min. SCH 40 Chamber) C0 with plug Blind Flange with Float Stop Spring and a Mating Weld Neck Flange D0 with FNPT (see Note 2); 1/2 FNPT standard D0 with Plug (see Note 5); 1/2 standard D0 with Socket Weld Coupling D0 with FNPT Coupling D0 with Nipple, for Socket Welding (flat) D0 with Nipple, for Butt Welding (37.5 Bevel) D0 with Nipple, MNPT D0 with Top Mount Indicator D0 with Reducing Spool and Flange (See Note 7) D0 with Socket Weld Bore (see Note 3); 1/2 SW Standard Weld Neck Flange connected to chamber via Extruded Outlet (see Note 4) Weld Neck Flange (see Note 1) FE with Pipe Between Chamber & Weld Neck Flange (See Note 4) Weld Neck Flange with Weld-o-let (Min. SCH 40 Chamber) Weld Neck Flange with Weld-o-let and Concentric Reducer (Min. SCH 40 Chamber) Weld Neck Flange with Concentric Reducer connected to chamber via Extruded Outlet (see Note 4) Weld Neck Flange with Concentric Reducer Weld Neck Flange with Butt Weld Tee Slip-On Flange connected to chamber via Extruded Outlet (see Note 4) Slip-On Flange (See Note 1) Slip-On Flange with Weld-o-let and Pipe Nipple Slip-On Flange with Concentric Reducer connected to chamber via Extruded Outlet (See Note 4) Slip-On Flange with Butt Weld Tee and Pipe Nipple Indicator with Blind Flange Indicator with Blind Flange and removable Stilling Well Indicator with MNPT Plug Indicator with MNPT Plug with integral Stilling Well
21
CHAMBER CONFIGURATION
Table 1 - Code Options / Definitions
L LE L4 N0E N0 N2E N2 N3E N3 N6 S0 S1 S2 SW SWE T0 T2 T3 T4 T5 T6 T7 T9 W0 W1 W2 W3 W4 W5 W6 W7 W9 W10 X Stub End with Loose (Lap Joint) Flange Stub End with Loose (Lap Joint) Flange connected to chamber via Extruded Outlet (see Note 4) Stub End with Lap Joint Flange and Butt Weld Tee Branch Nipple for Socket Weld (Flat) connected to chamber via Extruded Outlet (see Note 4) Branch Nipple for Socket Weld (Flat) Branch Nipple for Butt Welding (37.5 Bevel) connected to chamber via Extruded Outlet (see Note 4) Branch Nipple for Butt Welding (37.5 Bevel) MNPT Branch Nipple connected to chamber via Extruded Outlet (see Note 4) MNPT Branch Nipple Weld-o-let for Butt Welding (Min. SCH 40 Chamber) Screwed Pipe Cap with Float Stop Spring (Min. SCH 40 Chamber) S0 with FNPT (see Note 2); 1/2 FNPT Standard (Min. SCH 40 Chamber) S0 with Plug (Min. SCH 40 Chamber) Socket Weld flange (see note 1) Socket Weld flange connected to chamber via Extruded outlet (see note 4) Butt Welded Dome Pipe Cap T0 with FNPT Coupling and Plug T0 with Socket Weld Coupling T0 with FNPT Coupling T0 with Nipple, for Socket Welding (Flat) T0 with Nipple, for Butt Welding (37.5 Bevel) T0 with Nipple, MNPT T0 with Nipple and Flange (See Note 7) Welded Flat Pipe Cap with Float Stop Spring W0 with FNPT (See Note 2); 1/2 FNPT standard W0 with Plug (See Note 5); 1/2 Standard W0 with Socket Weld Coupling W0 with FNPT Coupling W0 with Nipple, for Socket Welding (Flat) W0 with Nipple, for Butt Welding (37.5 Bevel) W0 with Nipple, MNPT W0 with Nipple and Flange (See Note 7) W0 with Socket Weld Bore (see Note 3); 1/2 SW Standard No Connection
Note 1: When a Weld Neck Flange (F0), a Fixed Flange (G) or (SW) option is a process connection on either end of the chamber as shown in the configuration tables these will be provided with a float stop bar or disk and spring to keep the float confined in the chamber. Note 2: 1/2 FNPT Standard; Optional FN7 (3/4) or FN1 (1). Specify after option D. Note 3: 1/2 SW Standard; Optional SW7 (3/4). Specify after option D. COUPLING SIZES Note 4: Extruded outlet can be utilized as follows FLANGES & NIPPLES Stainless Steel: Sch. 10 chambers with 1, 1-1/2 & 2 connections 3/4, 1, 1 1/4 1 1/4 Sch. 40 chambers with 1-1/2 & 2 connections 6 Alloy 20: Sch. 10 chambers with 1-1/2 & 2 connections 1 1/4 Hastelloy: Sch. 10 chambers with 1-1/2 & 2 connections 1 1/4 Note 5: 1/2 plug Standard; see Table 2 (Page 26) for additional sizes. Note 6: Cannot extrude SCH 40 seamless pipe. Note 7: Select B9, D9, T9 or W9 when flange connections are smaller than the chamber size at either the top and / or bottom of KM26.
22
CHAMBER CONFIGURATONS
TOP
Table 1 - Code Options / Graphics B0 B1 B2 B3 B4 B5 B6
B7
B9
B10
D0
D1
D2
D3
D4
D5
D6
D7
D9
D10
F0
S0
S1
S2
T0
T2
T3
T4
T5
T6
T7
T9
W0
W1
OR
W2
W3
W4
W5
W6
W7
W9
OR
W10
23
CHAMBER CONFIGURATONS
SIDE
Table 1 - Code Options / Graphics C0 C0L C0E C1 C1L C2 FE
F0
F0E
F1
F2
F3
F3E
GE
G1
G3E
LE
L4
N0E
NO
N2E
N2
N3E
N3
N6
SW
SWE
24
CHAMBER CONFIGURATONS
BOTTOM
Table 1 - Code Options / Graphics B0 B1 B2 B3 B4 B5 B6
B7
B9
B10
D0
D1
D2
D3
D4
D5
D6
D7
D9
D10
F0
S0
S1
S2
T0
T2
T3
T4
T5
T6
T7
T9
OR
W0
W1
W2
W3
W4
W5
W6
W7
W9
OR
W10
25
1. Extruded Outlets are full bore up to a maximum of 2 See Note 4, Table 1 on page 23. 2. 1/2 to 2 1/2 flanges use 1500# if 900# is specified. 3. Flat face flanges can be supplied with the (SF) or (WF) designator. (i.e. For a 150# flat face slip-on. . . SF51) Nipples: Sch. 40 Std. Plugs: 1/2 Std. N54 N58 N51 N74 N78 N71 N14 N18 N11 1/2 3/4 1 2 3 4 6 P5 P7 P1 P2 P3 P4 P6
Threaded Couplings:
1/2 3/4 1 3000# 3000# 3000# C53 C73 C13
Sch. 40 Sch. 80 Sch. 160 Sch. 40 Sch. 80 Sch. 160 Sch. 40 Sch. 80 Sch. 160 Screw-On Caps:
Sock-o-lets S23 S253 S33 S43 1/2 3/4 1 1-1/2 2 3000# 3000# 3000# 3000# 3000# S05 S07 S10 S15 S20 1/2 3/4 1 1-1/2 2 1/2 3/4 1 1-1/2 2
Thread-o-lets: 3000# 3000# 3000# 3000# 3000# 6000# 6000# 6000# 6000# 6000# T053 T073 T103 T153 T203 T056 T076 T106 T156 T206
2 2-1/2 3 4
26
Magnetic Level Gauge Switches MS30 MS40 MS41 PS35 PS45 Refer to MS30-0202-1 Data Sheet for Ordering Information Refer to MS40-0202-1 Data Sheet for Ordering Information Refer to MS41-0202-1 Data Sheet for Ordering Information Refer to PS35-0202-1 Data Sheet for Ordering Information Refer to PS45-0202-1 Data Sheet for Ordering Information
Vibrating Level Switch RS80 RS85 Refer to RS80-0202-1 Data Sheet for Ordering Information Refer to RS85-0202-1 Data Sheet for Ordering Information
Thermal Dispersion Switch TX Refer to TX-0202-1 Data Sheet for Ordering Information
Sample Accessories
KM26 with AT200 & MS41 KM26 with (2) MS40EXs KM26 with (1) TX & (1) RS80
27
EXAMPLE APPLICATIONS
C B
Top Process from side and Bottom Process from bottom of KM26 Example: KM26S/SS4/W0FEXG/WR-21-SR21/S1P/B/58/48 Top: Flat Pipe Cap w/ Float Stop Spring Side: Top RFWN w/ Extruded Outlet Bottom: No Process Connection Bottom: RF Slip-On Flange w/ Float Stop Spring
M L
M L
Top Process and Bottom Process from top and bottom of KM26 Example: KM26S/SS6/GXXG/SR21/S1P/B/64.5/48 Top: RF Slip-On Flange w/ Float Stop Spring Side: Top None Bottom: None Bottom: RF Slip-On Flange w/ Float Stop Spring
Top and Bottom Process Connection from side of KM26 Example: Top: Side: Bottom: KM26S/SS6/W0FEFEB0/WR21/S1P/B/48 Flat Pipe Cap w/ Float Stop Spring 2 ea. RFWN w/ Extruded Outlets Blind Flange w/ Float Stop Spring and Matching Slip-On Flange -total level -crude oil -0.80 s.g. at operating conditions -100 psig operating, 200 psig maximum -150F operating, 175F maximum -center to center 48 -measuring length 48
B
M L
28
EXAMPLE APPLICATIONS
Top Process from top and Bottom Process from bottom side of KM26 Example: KM26S/SS6/G(3)GEB0/SR251-SR21/S1P/42.5/36 Top: RF Slip-On Flange w/ Float Stop Spring Side: Top: RF Slip-On Flange Middle: RF Slip-On Flange Bottom: RF Slip-On Flange Bottom: Slip-On Flange w/ Float Stop Spring -interface level -oil / water -oil s.g. 0.80 @ operating conditions; water s.g. 1.00 @ operating conditions -100 psig operating, 200 psig maximum -150F operating, 175F maximum -center to face 42.5 -measuring length 36
Dual Level Application Example: Top: Side: KM26S/SS6/W0(3)FEB0/WR21/M1P/M2P/B/48 Flat Pipe Cap w/ Float Stop Spring Top: RFWN w/ Extruded Outlet Middle: RFWN w/ Extruded Outlet Bottom: RFWN w/ Extruded Outlet Blind Flange w/ Float Stop Spring and Matching Slip-On Flange -upper fluid level (yellow/black MBG-M1P) & interface level (red/white MBG-M2P) -crude oil & water -oil s.g. = 0.80 @ operating conditions; water s.g. 1.0 @ operating conditions -100 psig operating, 200 psig maximum -150F operating temperature, 175F maximum -center to center 48 -measuring length 48
B
Bottom:
M L
29
EXAMPLE APPLICATIONS
KM26T TOP MOUNT UNITS
Tank with Top Opening and with Stilling Well. Example: KM26T/SS6/H1/SR41/S1P/B/45/34 Top: Indicator with Blind Flange mounted on tank with existing stilling well
ML ML
54" 45
54"
ML ML
H0
H1
H2
H3
ML
ML
ML
ML
IL
IL
IL
IL
3 in 0
3 in 0
B8
D8
30
Contact: Fax:
Upper fluid ______________Upper fluid specific gravity at operating conditions ___________ Range _________ Lower fluid _____________Lower fluid specific gravity at operating conditions ___________ Range__________ Operating Temp Chamber & Float Details: Chamber Material Max Temp Stilling Well Material (for H1 and H3 options) Process Connection Type: Diameter Operating Press Max Press Float Material
Size Schedule
Rating
If yes, Height
Indicator Details: Shuttle Yellow/Black MBG Red/White MBG Scale: Feet/Inch Meter/cm Custom Running In. (1/2 Div.) Running In. (1/8 Div.) Foundation Fieldbus HART LCD Honeywell DE
Special Requirements Accessories Required: (Circle all that apply.) Switches (Specify) Transmitter AT200 or AT600
Area Classification, Ratings or Approvals required: Circle the appropriate configuration below or attach a sketch: Note: Insertion length will always be greater than measuring length (ML). Please specify available insertion length (IL) and required measure length (ML). KM26T insertion lengths (IL) >24 require a stilling well. KM26T Configuration Options Option #1: $ ea.
H0
ML
H1
ML
H2
ML
H3
Option #2:
ML
$ $
ea. ea.
Option #3:
Option #4:
IL IL IL IL
ea.
31
Contact: Fax:
Interface Level
Operating Temp Max Temp Operating Press High Vibration Environment (Compressor Etc.) YES or NO (circle) Chamber & Float Details: Chamber Material Process Connection Type: Center to Center/Measuring Length Indicator Details: Shuttle Yellow/Black MBG Red/White MBG Scale: Float Material Size
Max Press
Feet/Inch Meter/cm Custom Running In. (1/2 Div.) Running In. (1/8 Div.)
Special Requirements Accesssories Required (circle all that apply): Chamber Electric Heat Steam or Steam Specialty Magnetic Switches Transmitter Insulation Tracing* Water Jacket Tracing Process Particle (Specify) AT200 or AT600 * Specify Type:___________________________ Connection Traps (Specify) Area Classification, Ratings or Approvals required: Circle the appropriate configuration below or attach a sketch: Foundation FB HART LCD Honeywell DE Select Orientation: Indicator A B C Transmitter A B C Switch(es) A B C
FIG. A
FIG. B
FIG. C
FIG. D
FIG. E
FIG. F
FIG. G
A B
Note: Overall length will always be greater than measuring length (ML). Please specify if a max overall length is required.
Quotation#:____________________By:__________Date:__________