ADS Configuration Guide
ADS Configuration Guide
0 (without SSL)
Assign the role ADSCALLERS to ADSUSER along with the following roles,
SAP_BC_FP_ICF
SAP_BC_FPADS_ICF
SAP_BC_JSF_COMMUNICATION
1. Go to Visual Admin
2. On the Cluster tab, choose Server <x> → Services → Security Provider.
3. On the User Management tab, choose the Tree tab in the left panel.
4. In the User Tree, ensure that the user you created in ABAP appears under the
ADSCALLERS group.
5. On the Policy Configurations tab, in the Components area, select
com.adobe/AdobeDocumentServices*AdobeDocumentServicesAssembly.jar.
6. On the Security Roles tab, select ADSCALLER from the Security Roles list.
7. In the Mappings area, choose Add, which is assigned to Users. A dialog Choose Users
or Groups is displayed.
8. Choose the Tree tab.
9. In the User Tree, under the ADSCALLERS group, select the ADSUSER you just created
and choose OK. This assigns the new user to the ADSCALLERS security role.
Create ABAP RFC Connection (SM59)
FP_ICF_DATA_<SID>
If you choose Save and Test, you can ignore the message Error during ping operation:
Received HTTP response 404.
Set up Basic Authentication in JAVA Environment
Configuration Check
I
➢ Go to SA38
➢ Test program FP_TEST_00
➢ If the FP_TEST_00 form is displayed in the print preview, the ADS configuration is
correct.
If the system displays an error message instead of a form, the configuration of ADS is incorrect
. The carry out additional tests. Go for STEP II
II
➢ Now check RFC connection to ADS by Program FP_ADS_TEST_00 in SA38
➢ If the system displays the version number of ADS, the configuration of the RFC
connection is correct. Then Proceed with III
Otherwise You receive one of the following error messages:
1. If the system displays dialog fields for user and password instead of the version
number, the entries for user and password in the RFC connection do not match the entries in user
management.
-> Check the user and the password. Continue with point
-> Check or correct the details for target device, service number and path prefix in
the RFC connection (transaction SM59).
3. If the system displays an error message stating that there is no valid HTTP
connection, then there is no RFC connection to ADS.
b) Now select the option "With Destination Service" and execute the program again. The
system processes the test form, using the destination service.
• If the system displays the same message (file size of generated PDF) as it does in
a), the configuration of the destination service is correct.
IV If you get the error FPRUNX004 while executing any of the above tests do the following,
1. Go to SE37
2. execute the function module FP_GET_LAST_ADS_ERRSTR
After you have called the FP_GET_LAST_ADS_ERRSTR function module, the system will delete the
text internally. A second call will, therefore, not return any results.
Document Prepared by
RENJITH R
RAJESH LS