0% found this document useful (0 votes)
166 views38 pages

Hydrogen Future of Energy Storage

seminar report which is having importance in present situation. the system describing here is based on renewa
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
166 views38 pages

Hydrogen Future of Energy Storage

seminar report which is having importance in present situation. the system describing here is based on renewa
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 38

HYDROGEN FUTURE OF ENERGY STORAGE

CHAPTER 1 INTRODUCTION
1.1 INTRODUCTION ENERGY conversion from renewable energy (RE) sources, in particular through wind turbine generators (WTGs) and photovoltaic (PV) arrays with suitable energy storage can play an important role in the development and operation of RE systems. The integrated WTG and PV array system, based on long-term seasonal energy storage as electrolytic hydrogen, is considered a promising alternative to overcome the intermittence of the RE sources. In comparison to commonly used battery storage, is well suited for seasonal storage applications because its inherent high mass energy density leakage from the storage tank is insignificant and it is easy to install anywhere. A typical self-sufficient RE system must include both short-term and long-term energy storage. A battery bank is commonly used for short-term energy storage due to its high round-trip efficiency, convenience for charging/discharging, and also to take care of the effects caused by instantaneous load ripples/spikes, electrolyzer transients, wind energy peaks. However, batteries alone are not appropriate for long-term energy storage because of their low energy density, self-discharge, and leakage. The combination Of a battery bank with long-term energy storage in the form of can significantly improve the performance of stand-alone RE systems. Also, the overall RE system performance is very sensitive to local weather conditions. Thus, to achieve an adequate performance from such a complex system, one requires appropriate components and a well-designed control system in order to achieve autonomous operation and energy management in the system. The Hydrogen Research Institute (HRI) has designed and developed a control system with power conditioning devices to manage the energy flow throughout a RE system to assure continuous supply of energy to the load. A major emphasis of this work is to test the developed control system for autonomous long-term operation and technical feasibility of the stand
DEPT. OF EEE MEA ENGG COLLEGE PMNA

HYDROGEN FUTURE OF ENERGY STORAGE

alone RE system based on. The system parameters are monitored continuously for real-time operation and control. A new methodology, based on the differences between wind power generation and load variability, was developed in this study to optimize the technology, energy capacity and power transfer of the hydrogen energy storage method for specified applications. The dynamics of the complete hydrogen cycle energy storage and recovery mechanism was investigated, specifically for potential applications such as power smoothing and peak lopping. A time dependant model of the efficiency of various hydrogen storage technologies, including high pressure compression, low temperature liquefaction, metal hydrides and complex hydrides, has been developed. Based on this study, a practical hydrogen energy storage system for a 5MW micro-grid application was designed 1.2 WHY HYDROGEN? Why Hydrogen? Hydrogen is one of the promising alternatives that can be used as an energy carrier. Hydrogen can be stored in vessels for later use as does electricity in batteries. Many European countries have established hydrogen transmission pipes, nearly 1600 km, and consider Hydrogen fuels as a prime source for new energy supply. Electricity is used in electrolysers to split water molecules into hydrogen and oxygen. Many industrial processes require hydrogen as an ingredient, or produce hydrogen as a by-product. Hydrogen is used in refineries, and also in the ammonia, methanol and metal industry. The majority of hydrogen production facilities are based on using excess power from fossil and nuclear power generating plants during low peak demand. RES based hydrogen production offers a source of domestic and vehicular energy with safer and lower levels of pollution. Hydrogen as automobile fuel is well known and has been used in many countries.Recently, the United States, Canada and 13 other nations established the International Partnership for the Hydrogen Economy (IPHE) to coordinate hydrogen research, development and technology, and have committed to a roadmap that will put hydrogen vehicles in showrooms within the next 15 years.

DEPT. OF EEE

MEA ENGG COLLEGE PMNA

HYDROGEN FUTURE OF ENERGY STORAGE

Fossil fuels, which are non-renewable and will eventually exhausted, produce large amounts of carbon dioxide, which can not only bring environment pollution, but also can cause global warming. Therefore, reliable and affordable green energy is a cornerstone for sustainable development. One potential renewable energy resource is wind power. However, the intermittency of wind energy limits its penetration in electricity networks. Although the overall demand could be easily met by energy generated from wind turbines, there can be significant mismatches between the peak load and maximum wind power generation. To explore this problem a stand-alone demonstration power system with a wind turbine (600 kW) and hydrogen energy storage was launched at the island of Utsira in Norway. The hydrogen storage system includes water electrolysis (10 Nm/m3), compressed gas storage (2400 Nm3, 200 bar), hydrogen engine (55 kW), and a PEM fuel cell (10 kW) .In this system, a flywheel, a synchronous generator, and a battery system is employed to ensure the voltage and frequency. The system can supply 2-3 days full energy for 10 households. Another example is in Uckermark, Germany where mixed renewable energy generation such as wind, biogas, and solar energy is being studied with hydrogen storage system. This plant includes three wind turbines with a total capacity of 6 GW and a biogas unit producing gas from maize supplied by 21 local farmer

DEPT. OF EEE

MEA ENGG COLLEGE PMNA

HYDROGEN FUTURE OF ENERGY STORAGE

CHAPTER 2 TECHNIQUE USED FOR H2 PRODUCTION

2.1 Electrolysis of water Hydrogen can be made via high pressure electrolysis or low

pressure electrolysis of water. Current best processes have an efficiency of 50% to 80%,[21][22][23] so that 1 kg of hydrogen (which has an energy density of 143 MJ/kg, about 40 kWh/kg) requires 50 to 79 kWh of electricity with traditional methods and could be brought to 85% efficiency with new proposed methods, although efficiencies in the order of 100% are theoretically possible. At 8 cents/kWh, that's $4.00/kg, which is with traditional methods 3 to 10 times the price of hydrogen from steam reformation of natural gas.[14] The price difference is due to the efficiency of direct conversion of fossil fuels to produce hydrogen, rather than burning fuel to produce electricity. Hydrogen from natural gas, used to replace e.g. gasoline, emits more CO2 than the gasoline it would replace, and so is no help in reducing greenhouse gases.

High-pressure electrolysis High pressure electrolysis is the electrolysis of water by decomposition of water (H2O) into oxygen (O2) and hydrogen gas (H2) by means of anelectric current being passed through the water. The difference with a standard electrolyzer is the compressed hydrogen output around 120-200Bar (1740-2900 psi). By pressurising the hydrogen in the electrolyser the need for an external hydrogen compressor is eliminated, the average energy consumption for internal compression is around 3%

DEPT. OF EEE

MEA ENGG COLLEGE PMNA

HYDROGEN FUTURE OF ENERGY STORAGE

High-temperature electrolysis Hydrogen can be generated from energy supplied in the form of heat and electricity through high-temperature electrolysis (HTE). Because some of the energy in HTE is supplied in the form of heat, less of the energy must be converted twice (from heat to electricity, and then to chemical form), and so potentially far less energy is required per kilogram of hydrogen produced. While nuclear-generated electricity could be used for electrolysis, nuclear heat can be directly applied to split hydrogen from water. High temperature (950 1000 C) gas cooled nuclear reactors have the potential to split hydrogen from water by thermo chemical means using nuclear heat. Research into high-temperature nuclear reactors may eventually lead to a hydrogen supply that is cost-competitive with natural gas steam reforming. General Atomics predicts that hydrogen produced in a High Temperature Gas Cooled Reactor (HTGR) would cost $1.53/kg. In 2003, steam reforming of natural gas yielded hydrogen at $1.40/kg. At 2005 natural gas prices, hydrogen costs $2.70/kg. High-temperature electrolysis has been demonstrated in a laboratory, at 108 mega joules (thermal) per kilogram of hydrogen produced, but not at a commercial scale. In addition, this is lower-quality "commercial" grade Hydrogen, unsuitable for use in fuel cells. Photo electro chemical water splitting Using electricity produced by photovoltaic systems offers the cleanest way to produce hydrogen. Water is broken into hydrogen and oxygen by electrolysis a photo electrochemical cell (PEC) process which is also named artificial

photosynthesis. Research aimed toward developing higher-efficiency multi-junction cell technology is underway by the photovoltaic industry. Concentrating solar thermal Very high temperatures are required to dissociate water into hydrogen and oxygen. A catalyst is required to make the process operate at feasible temperatures. Heating the water can be achieved through the use of concentrating solar
DEPT. OF EEE MEA ENGG COLLEGE PMNA

HYDROGEN FUTURE OF ENERGY STORAGE

power. Hydrosol-2 is a 100-kilowatt pilot plant at the Plataforma Solar de Almeria in Spain which uses sunlight to obtain the required 800 to 1,200 C to heat water. Hydrosol II has been in operation since 2008. The design of this 100-kilowatt pilot plant is based on a modular concept. As a result, it may be possible that this technology could be readily scaled up to the megawatt range by multiplying the available reactor units and by connecting the plant to heliostat fields (fields of suntracking mirrors) of a suitable size. Photo electro catalytic production A method studied by Thomas Nann and his team at the University of East Anglia consists of a gold electrode covered in layers of indium phosphide (InP) nano particles. They introduced an iron-sulfur complex into the layered arrangement, which when submerged in water and irradiated with light under small electric current, produced hydrogen with an efficiency of 60%. Thermo chemical production There are more than 352 thermo chemical cycles which can be used for water splitting, around a dozen of these cycles such as the iron oxide cycle, cerium(IV) oxide-cerium(III) oxide cycle, zinc zinc-oxide cycle, sulfur-iodine cycle, copper-chlorine cycle and hybrid sulfur cycle are under research and in testing phase to produce hydrogen and oxygen from water and heat without using electricity.[33] These processes can be more efficient than high-temperature electrolysis, typical in the range from 35 % - 49 % LHV efficiency. Thermo chemical production of hydrogen using chemical energy from coal or natural gas is generally not considered, because the direct chemical path is more efficient. None of the thermo chemical hydrogen production processes have been demonstrated at production levels, although several have been demonstrated in laboratories.

DEPT. OF EEE

MEA ENGG COLLEGE PMNA

HYDROGEN FUTURE OF ENERGY STORAGE

CHAPTER3 HYDROGEN STORAGE&SAFETY

3.1 Storage Although molecular hydrogen has very high energy density on a mass basis, partly because of its low molecular weight, as a gas at ambient conditions it has very low energy density by volume. If it is to be used as fuel stored on board the vehicle, pure hydrogen gas must be pressurized or liquefied to provide sufficient driving range. Increasing gas pressure improves the energy density by volume, making for smaller, but not lighter container tanks (see pressure vessel). Achieving higher pressures necessitates greater use of external energy to power the compression. Alternatively, (252.882 C higher volumetric energy density liquid hydrogen or slush

hydrogen may be used. However, liquid hydrogen is cryogenic and boils at 20.268 K or 423.188 F). Cryogenic storage cuts weight but requires

large liquification energies. The liquefaction process, involving pressurizing and cooling steps, is energy intensive. The liquefied hydrogen has lower energy density by volume than gasoline by approximately a factor of four, because of the low density of liquid hydrogen there is actually more hydrogen in a liter of gasoline (116 grams) than there is in a liter of pure liquid hydrogen (71 grams). Liquid hydrogen storage tanks must also be well insulated to minimize boil off. Ice may form around the tank and help corrode it further if the liquid hydrogen tank insulation fails. The mass of the tanks needed for compressed hydrogen reduces the fuel economy of the vehicle. Because it is a small molecule, hydrogen tends to diffuse through any liner material intended to contain it, leading to the embrittlement, or weakening, of its container.

DEPT. OF EEE

MEA ENGG COLLEGE PMNA

HYDROGEN FUTURE OF ENERGY STORAGE

Distinct from storing molecular hydrogen, hydrogen can be stored as a chemical hydride or in some other hydrogen-containing compound. Hydrogen gas is reacted with some other materials to produce the hydrogen storage material, which can be transported relatively easily. At the point of use the hydrogen storage material can be made to decompose, yielding hydrogen gas. As well as the mass and volume density problems associated with molecular hydrogen storage, current barriers to practical storage schemes stem from the high pressure and temperature conditions needed for hydride formation and hydrogen release. For many potential systems hydriding and dehydrating kinetics and heat management are also issues that need to be overcome. A third approach is to absorb molecular hydrogen into a solid storage material. Unlike in the hydrides mentioned above, the hydrogen does not dissociate/recombine upon charging/discharging the storage system, and hence does not suffer from the kinetic limitations of many hydride storage systems. Hydrogen densities similar to liquefied hydrogen can be achieved with appropriate absorption media. Some suggested absorbers include MOFs, nanostructure carbons

(including CNTs) and clathrate hydrate. The most common method of on board hydrogen storage in today's demonstration vehicles is as a compressed gas at pressures of roughly 700 bar (70 MPa). Underground hydrogen storage is the practice of hydrogen storage in

underground caverns, salt domes and depleted oil and gas fields. Large quantities of gaseous hydrogen are stored in underground caverns by ICI for many years without any difficulties. The storage of large quantities of hydrogen underground can function as grid energy storage which is essential for the hydrogen economy.

DEPT. OF EEE

MEA ENGG COLLEGE PMNA

HYDROGEN FUTURE OF ENERGY STORAGE

3.2 Hydrogen safety Hydrogen has one of the widest explosive/ignition mix range with air of all the gases with few exceptions such as acetylene, silane, and ethylene oxide. That means that whatever the mix proportion between air and hydrogen, a hydrogen leak will most likely lead to an explosion, not a mere flame, when a flame or spark ignites the mixture. This makes the use of hydrogen particularly dangerous in enclosed areas such as tunnels or underground parking. Pure hydrogen-oxygen flames burn in the ultraviolet color range and are nearly invisible to the naked eye, so a flame detector is needed to detect if a hydrogen leak is burning. Hydrogen is odorless and leaks cannot be detected by smell. Hydrogen codes and standards are codes and standards for hydrogen fuel cell vehicles, stationary fuel cell applications and portable fuel cell applications. There are codes and standards for the safe handling and storage of hydrogen, for example the Standard for the installation of stationary fuel cell power systems from the National Fire Protection Association. Codes and standards have repeatedly been identified as a major institutional barrier to deploying hydrogen technologies and developing a hydrogen economy. To enable the commercialization of hydrogen in consumer products, new model building codes and equipment and other technical standards are developed and recognized by federal, state, and local governments. One of the measures on the roadmap is to implement higher safety standards like early leak detection with hydrogen sensors. The Canadian Hydrogen Safety Program concluded that hydrogen fueling is as safe as, or safer than, CNG fueling. The European Commission has funded the first higher educational program in the world in hydrogen safety engineering at the University of Ulster. It is expected that the general public will be able to use hydrogen technologies in everyday life with at least the same level of safety and comfort as with today's fossil fuels.

DEPT. OF EEE

MEA ENGG COLLEGE PMNA

HYDROGEN FUTURE OF ENERGY STORAGE

10

3.3 Fuel cells as alternative to internal combustion One of the main offerings of a hydrogen economy is that the fuel can replace the fossil fuel burned in internal combustion engines and turbines as the primary way to convert chemical energy into kinetic or electrical energy; hereby eliminating greenhouse gas emissions and pollution from that engine. Although hydrogen can be used in conventional internal combustion engines, fuel cells, being electrochemical, have a theoretical efficiency advantage over heat engines. Fuel cells are more expensive to produce than common internal combustion engines, but are becoming cheaper as new technologies and production systems develop. Some types of fuel cells work with hydrocarbon fuels, while all can be operated on pure hydrogen. In the event that fuel cells become price-competitive with internal combustion engines and turbines, large gas-fired power plants could adopt this technology. Hydrogen gas must be distinguished as "technical-grade" (five nines pure), which is suitable for applications such as fuel cells, and "commercial-grade", which has carbon- and sulfur-containing impurities, but which can be produced by the much cheaper steam-reformation process. Fuel cells require high purity hydrogen because the impurities would quickly degrade the life of the fuel cell stack. Much of the interest in the hydrogen economy concept is focused on the use of fuel cells to power electric cars. Current Hydrogen fuel cells suffer from a low power-toweight ratio.[40] Fuel cells are much more efficient than internal combustion engines, and produce no harmful emissions. If a practical method of hydrogen storage is introduced, and fuel cells become cheaper, they can be economically viable to power hybrid fuel cell/battery vehicles, or purely fuel cell-driven ones. The economic viability of fuel cell powered vehicles will improve as the hydrocarbon fuels used in internal combustion engines become more expensive, because of the depletion of easily accessible reserves or economic accounting of environmental impact through such measures as carbon taxes.

DEPT. OF EEE

MEA ENGG COLLEGE PMNA

HYDROGEN FUTURE OF ENERGY STORAGE

11

Currently it takes 2 times as much energy to make a hydrogen fuel cell than is obtained from it during its service life.[41] Other fuel cell technologies based on the exchange of metal ions (i.e. zinc-air fuel cells) are typically more efficient at energy conversion than hydrogen fuel cells, but the widespread use of any electrical energy chemical energy electrical energy systems would necessitate the production of electricity.

DEPT. OF EEE

MEA ENGG COLLEGE PMNA

HYDROGEN FUTURE OF ENERGY STORAGE

12

CHAPTER 4 SYSTEM DESCRIPTION

Fig:1 system description


DEPT. OF EEE MEA ENGG COLLEGE PMNA

HYDROGEN FUTURE OF ENERGY STORAGE

13

The stand-alone RE system based on hydrogen production has been successfully tested at the HRI. The system consists of a 10-kW WTG and 1-kW (peak) PV array as primary energy sources. The excess energy with respect to the load requirement has been stored as electrolytic hydrogen through a 5-kW electrolyzer and utilized to produce electricity as per energy demand through a 5-kW fuel cell (FC) system. The electrolyzer and the FC system are major components of the RE system for energy storage as H2 and its re-utilization. Their performance (polarization) characteristics depend mainly on their voltage, current and temperature. The RE system components have substantially different voltage-current

characteristics and are integrated through the developed power conditioning devices on a 48-V dc bus, which allows power to be managed between input power, energy storage and load. The dc-dc buck and boost converters are connected for power conditioning between the electrolyzer and the dc bus, and between the FC and the dc bus, respectively. The schematic of the RE system is shown in Fig. 1 and the system components specifications are given in Table I. To simulate any type of electrical load profile, dc- and ac-programmable loads are used. The HRI developed RE system has also a 10-kW programmable power source connected on the dc Bus and can be used to test the system, when there is not enough power available from RE sources. The programmable power source can simulate any type of intermittent power output. Current from the dc bus bar keeps batteries (short-term energy storage) charged, feeds power to the load bank via an inverter and also supplies power to the electrolyzer via power-conditioning device. Sensors are critical for proper functioning of the entire system. The different sensors are used to record real time voltages and currents of WTG, PV array, dc bus/batteries, electrolyzer, FC, load, electrolytic H2 flow rate from the electrolyzer, consumption rate and oxidant consumption rate of the FC, H2 and oxidant pressure of the FC, FC stack temperature, electrolyzer cell temperature, dc-dc converter (boost and buck) duty ratio,H2 detectors.
DEPT. OF EEE MEA ENGG COLLEGE PMNA

HYDROGEN FUTURE OF ENERGY STORAGE

14

The control system is complex and was a real challenge to design, because the sensor data are required for decision-making and continuous real time autonomous operation, and the same control algorithm sends signals to the power conditioning devices on a real time basis for effective operation of the RE system.

4.2 System Control The control system manages the energy flow among the different components of the RE system. The control system consists a master controller for the overall energy management, and secondary micro controllers, which manage the energy, flow through power conditioning devices [10]. The control system has been designed to maximize the direct energy flow from the RE sources to the electrolyzer and the load in order to avoid losses in the buffer energy storage i.e., batteries. The dc bus voltage depends on the operating conditions of the system. Due to the intermittent nature of the RE sources; it varies instan instantaneously. It also changes during battery charging/discharging, load peaks, electrolyzer ripples. The dc bus voltage alone cannot be considered as a decision variable to control the operation of RE system. The energy level at dc bus i.e., batteries energy level [state-of-charge (SOC)] plays an important role for operation and control of the RE system and it depends on the available energy from the primary sources, the load requirement and the FC system output power. It allows effective energy management among them. With respect to the energy level at the dc bus and pre-defined limits of energy levels in the control algorithm, the master controller sends the conditioned signal (duty ratio) to the secondary controllers for on/off operation of the electrolyzer and the FC. As the specified energy levels at the dc bus are reached, the control algorithm sends a conditioned signal (duty ratio) through microcontrollers to the buck/boost converters for effective operation of the electrolyzer/FC system. The secondary micro-controllers manage the power flow of electrolyzer and FC, with respect to the energy availability at the dc bus through the digitally controlled dc-dc converters. The dc-dc converters use multiphase technique to generate pulse width modulation signals to control the power flow.
DEPT. OF EEE MEA ENGG COLLEGE PMNA

HYDROGEN FUTURE OF ENERGY STORAGE

15

The limits of energy levels in the control algorithm have been managed through the double hysteresis strategy. The control algorithm has been developed in such a way that the FC and the electrolyzer do not operate simultaneously.

4.3 Boost converter A boost converter (step-up converter) is a power converter with an output DC voltage greater than its input DC voltage. It is a class of switching-mode power supply (SMPS) containing at least two semiconductor switches (a diode and a transistor) and at least one energy storage element. Filters made of capacitors (sometimes in combination with inductors) are normally added to the output of the converter to reduce output voltage ripple.

Fig:2 boost converter

The switch is typically a MOSFET, IGBT, or BJT.

Overview

Power can also come from DC sources such as batteries, solar panels, rectifiers and DC generators. A process that changes one DC voltage to a different DC voltage is called DC to DC conversion. A boost converter is a DC to DC converter with an output voltage greater than the source voltage. A boost converter is sometimes called
DEPT. OF EEE MEA ENGG COLLEGE PMNA

HYDROGEN FUTURE OF ENERGY STORAGE

16

a step-up converter since it steps up the source voltage. Since power (P = VI) must be conserved, the output current is lower than the source current. History For high efficiency, the SMPS switch must turn on and off quickly and have low losses. The advent of a commercial semiconductor switch in the 1950s represented a major milestone that made SMPSs such as the boost converter possible. Semiconductor switches turned on and off more quickly and lasted longer than other switches such as vacuum tubes and electromechanical relays. The major DC to DC converters were developed in the early 1960s when semiconductor switches had become available. The aerospace industrys need for small, lightweight, and efficient power converters led to the converters rapid development. Switched systems such as SMPS are a challenge to design since its model depends on whether a switch is opened or closed. R.D. Middlebrook from Caltech in 1977 published the models for DC to DC converters used today. Middlebrook averaged the circuit configurations for each switch state in a technique called state-space averaging. This simplification reduced two systems into one. The new model led to insightful design equations which helped SMPS growth. Applications Battery powered systems often stack cells in series to achieve higher voltage. However, sufficient stacking of cells is not possible in many high voltage applications due to lack of space. Boost converters can increase the voltage and reduce the number of cells. Two battery-powered applications that use boost converters are hybrid electric vehicles (HEV) and lighting systems. The NHW20 model Toyota Prius HEV uses a 500 V motor. Without a boost converter, the Prius would need nearly 417 cells to power the motor. However, a Prius actually uses only 168 cells and boosts the battery voltage from 202 V to 500 V. Boost converters also power devices at smaller scale applications, such as portable lighting systems. A white LED typically requires 3.3 V to emit light, and a boost converter can step up the voltage from a single 1.5 V alkaline cell to power the lamp. Boost converters can also produce higher voltages to operate cold cathode fluorescent tubes (CCFL) in devices such as LCD backlights and some flashlights.
DEPT. OF EEE MEA ENGG COLLEGE PMNA

HYDROGEN FUTURE OF ENERGY STORAGE

17

A boost converter is used as the voltage increase mechanism in the circuit known as the 'Joule thief'. This circuit topology is used with low power battery applications, and is aimed at the ability of a boost converter to 'steal' the remaining energy in a battery. This energy would otherwise be wasted since the low voltage of a nearly depleted battery makes it unusable for a normal load. This energy would otherwise remain untapped because many applications do not allow enough current to flow through a load when voltage decreases. This voltage decrease occurs as batteries become depleted, and is a characteristic of the ubiquitous alkaline battery. Since (P = V2 / R) as well, and R tends to be stable, power available to the load goes down significantly as voltage decreases. Circuit analysis

Operating principle The key principle that drives the boost converter is the tendency of an inductor to resist changes in current. When being charged it acts as a load and absorbs energy (somewhat like a resistor); when being discharged it acts as an energy source (somewhat like a battery). The voltage it produces during the discharge phase is related to the rate of change of current, and not to the original charging voltage, thus allowing different input and output voltages.

The basic principle of a Boost converter consists of 2 distinct states

in the On-state, the switch S (see figure 1) is closed, resulting in an increase in the inductor current;

in the Off-state, the switch is open and the only path offered to inductor current is through the fly back diode D, the capacitor C and the load R. These results in transferring the energy accumulated during the On-state into the capacitor.

The input current is the same as the inductor current as can be seen in figure 2. So it is not discontinuous as in the buck converter and the requirements on the input filter are relaxed compared to a buck converter.

DEPT. OF EEE

MEA ENGG COLLEGE PMNA

HYDROGEN FUTURE OF ENERGY STORAGE

18

Continuous mode When a boost converter operates in continuous mode, the current through the inductor (IL) never falls to zero. During the Off-state, the switch S is open, so the inductor current flows through the load. If we consider zero voltage drop in the diode, and a capacitor large enough for its voltage to remain constant As we consider that the converter operates in steady-state conditions, the amount of energy stored in each of its components has to be the same at the beginning and at the end of a commutation cycle. 4.4 BUCK CONVERTER A buck converter is a step-down DC to DC converter. Its design is similar to the step-up boost converter, and like the boost converter it is a switchedmode power supply that uses two switches (a transistor and a diode), an inductor and a capacitor. The simplest way to reduce the voltage of a DC supply is to use a linear regulator (such as a 7805), but linear regulators waste energy as they operate by bleeding off excess power as heat. Buck converters, on the other hand, can be remarkably efficient (95% or higher for integrated circuits), making them useful for tasks such as converting the 1224 V typical battery voltage in a laptop down to the few volts needed by the processor.

Theory of operation The operation of the buck converter is fairly simple, with an inductor and two switches (usually a transistor and a diode) that control the inductor. It alternates between connecting the inductor to source voltage to store energy in the inductor and discharging the inductor into the load. Continuous mode A buck converter operates in continuous mode if the current through the inductor (IL) never falls to zero during the commutation cycle. In this mode

When the switch pictured above is closed (On-state, top of figure 2), the voltage across the inductor is VL = Vi Vo. The current through the inductor

DEPT. OF EEE

MEA ENGG COLLEGE PMNA

HYDROGEN FUTURE OF ENERGY STORAGE

19

rises linearly. As the diode is reverse-biased by the voltage source V, no current flows through it;

When the switch is opened (off state, bottom of figure 2), the diode is forward biased. The voltage across the inductor is VL = Vo (neglecting diode drop). Current IL decreases.

Discontinuous mode In some cases, the amount of energy required by the load is small enough to be transferred in a time lower than the whole commutation period. In this case, the current through the inductor falls to zero during part of the period. The only difference in the principle described above is that the inductor is completely discharged at the end of the commutation cycle (see figure 5). This has, however, some effect on the previous equations.

Output voltage ripple Output voltage ripple is the name given to the phenomenon where the output voltage rises during the On-state and falls during the Off-state. Several factors contribute to this including, but not limited to, switching frequency, output capacitance, inductor, load and any current limiting features of the control circuitry. At the most basic level the output voltage will rise and fall as a result of the output capacitor charging and discharging: During the Off-state, the current in this equation is the load current. In the On-state the current is the difference between the switch current (or source current) and the load current. The duration of time (dT) is defined by the duty cycle and by the switching frequency. Qualitatively, as the output capacitor or switching frequency increase, the magnitude of the ripple decreases. Output voltage ripple is typically a design specification for the power supply and is selected based on several factors. Capacitor selection is normally determined based on cost, physical size and non-idealities of various capacitor types. Switching frequency selection is typically determined based on efficiency requirements, which tends to decrease at higher operating frequencies, as described

DEPT. OF EEE

MEA ENGG COLLEGE PMNA

HYDROGEN FUTURE OF ENERGY STORAGE

20

below in Effects of non-ideality on the efficiency. Higher switching frequency can also reduce efficiency and possibly raise EMI concerns. Output voltage ripple is one of the disadvantages of a switching power supply, and can also be a measure of its quality. Effects of non-ideality on the efficiency A simplified analysis of the buck converter, as described above, does not account for non-idealities of the circuit components nor does it account for the required control circuitry. Power losses due to the control circuitry are usually insignificant when compared with the losses in the power devices (switches, diodes, inductors, etc.) The non-idealities of the power devices account for the bulk of the power losses in the converter. Both static and dynamic power losses occur in any switching regulator. Static power losses include I2R (conduction) losses in the wires or PCB traces, as well as in the switches and inductor, as in any electrical circuit. Dynamic power losses occur as a result of switching, such as the charging and discharging of the switch gate, and are proportional to the switching

4.5 HYDROGEN STORAGE Hydrogen has a very high enthalpy of 120MJ/kg [5], which is about 3 times that of Gasoline. Therefore, hydrogen is a good candidate as an energy carrier and methods for its storage have been investigated intensively. Five basic methods are proposed in the literature for hydrogen storage: compressed and stored in a pressure tank; cooled to a liquid state and kept cold in an insulated tank; physisorpted in carbon; metal hydrides and complex compounds. In order to choose the optimize method to integrate in the wind power system; the hydrogen storage capacity of each method has been compared, see Figure 2. As can be seen, metal hydrides and complex compounds occupy a smaller volume to store the same amount of hydrogen; however, this method is not suitable for this application due to its high ad/absorption temperature. Both liquid hydrogen and compressed gas at high pressure were better candidates for suitable methods for this project, however, liquid hydrogen requires more expensive equipments and very low temperature. Figure there are various
DEPT. OF EEE MEA ENGG COLLEGE PMNA

HYDROGEN FUTURE OF ENERGY STORAGE

21

inefficiencies involved with storage and recovery of electrical energy via the use of hydrogen. Energy is consumed to place the hydrogen in storage. This varies with the different energy storage approaches, the efficiency of each method is summarized in Table 1. From this we see that the energy lost to compress the gas is relatively low and therefore yields higher conversion efficiency. Activated carbon also has a high efficiency; however, a very low temperature is required during the process. During the storage period, the hydrogen leakage rate should also be considered because it is part of systems dynamic efficiency. As shown in Table.1, the compressed gas method has a very low leakage rate compared to the other methods. Without considering the operational losses, the main los The excess produced energy has been stored in the form of Electrolytic H2 through the electrolyzer unit, which consists of a control unit, a compressor, and purification and drying process. The electrolyzer input power consists of the cell and the parasitic power consumption of the H2 production process. The parasitic component consists of the power for the process control and the power for the gashandling unit, i.e., the compressor. s in compressed gas is permeation.

4.6 FUEL CELLS A single fuel cell consists of an electrolyte sandwiched between two electrodes, an anode and a cathode. Bipolar plates on either side of the cell help distribute gases and serve as current collectors. In a Polymer Electrolyte Membrane (PEM) fuel cell, which is widely regarded as the most promising for light-duty transportation, hydrogen gas flows through channels to the anode, where a catalyst causes the hydrogen molecules to separate into protons and electrons. The membrane allows only the protons to pass through it. While the protons are conducted through the membrane to the other side of the cell, the stream of negatively-charged electrons follows an external circuit to the cathode. This flow of electrons is electricity that can be used to do work, such as power a motor.

DEPT. OF EEE

MEA ENGG COLLEGE PMNA

HYDROGEN FUTURE OF ENERGY STORAGE

22

Fig:3 fuel cell On the other side of the cell, oxygen gas, typically drawn from the outside air, flows through channels to the cathode. When the electrons return from doing work, they react with oxygen and the hydrogen protons (which have moved through the membrane) at the cathode to form water. This union is an exothermic reaction, generating heat that can be used outside the fuel cell. The power produced by a fuel cell depends on several factors, including the fuel cell type, size, temperature at which it operates, and pressure at which gases are supplied. A single fuel cell produces approximately 1 volt or less barely enough electricity for even the smallest applications. To increase the amount of electricity generated, individual fuel cells are combined in series to form a stack. (The term fuel cell is often used to refer to the entire stack, as well as to the individual cell.) Depending on the application, a fuel cell stack may contain only a few or as many as hundreds of individual cells layered together. This scalability makes fuel cells ideal
DEPT. OF EEE MEA ENGG COLLEGE PMNA

HYDROGEN FUTURE OF ENERGY STORAGE

23

for a wide variety of applications, from laptop computers (50-100 Watts) to homes (15kW), vehicles (50-125 kW), and central power generation (1-200 MW or more). Types of Fuel Cells Fuel cells are classified primarily by the kind of electrolyte they employ. This classification determines the kind of chemical reactions that take place in the cell, the kind of catalysts required, the temperature range in which the cell operates, the fuel required, and other factors. These characteristics, in turn, affect the applications for which these cells are most suitable. There are several types of fuel cells currently under development, each with its own advantages, limitations, and potential applications. Learn more about:

Polymer Electrolyte Membrane (PEM) Fuel Cells Direct Methanol Fuel Cells Alkaline Fuel Cells Phosphoric Acid Fuel Cells Molten Carbonate Fuel Cells Solid Oxide Fuel Cells Regenerative Fuel Cells Comparison of Fuel Cell Technologies

Polymer Electrolyte Membrane (PEM) Fuel Cells

DEPT. OF EEE

MEA ENGG COLLEGE PMNA

HYDROGEN FUTURE OF ENERGY STORAGE

24

Fig:4 PEM fuel cell Polymer electrolyte membrane (PEM) fuel cellsalso called proton exchange membrane fuel cellsdeliver high-power density and offer the advantages of low weight and volume, compared with other fuel cells. PEM fuel cells use a solid polymer as an electrolyte and porous carbon electrodes containing a platinum catalyst. They need only hydrogen, oxygen from the air, and water to operate and do not require corrosive fluids like some fuel cells. They are typically fueled with pure hydrogen supplied from storage tanks or on-board reformers. Polymer electrolyte membrane fuel cells operate at relatively low temperatures, around 80C (176F). Low-temperature operation allows them to start quickly (less warm-up time) and results in less wear on system components, resulting in better durability. However, it requires that a noble-metal catalyst (typically platinum) be used to separate the hydrogen's electrons and protons, adding to system cost. The platinum catalyst is also extremely sensitive to CO poisoning, making it necessary to employ an additional reactor to reduce CO in the fuel gas if the hydrogen is derived from an alcohol or hydrocarbon fuel. This also adds cost. Developers are currently exploring platinum/ruthenium catalysts that are more resistant to CO. PEM fuel cells are used primarily for transportation applications and some stationary applications. Due to their fast startup time, low sensitivity to orientation,

DEPT. OF EEE

MEA ENGG COLLEGE PMNA

HYDROGEN FUTURE OF ENERGY STORAGE

25

and favorable power-to-weight ratio, PEM fuel cells are particularly suitable for use in passenger vehicles, such as cars and buses. A significant barrier to using these fuel cells in vehicles is hydrogen storage. Most fuel cell vehicles (FCVs) powered by pure hydrogen must store the hydrogen on-board as a compressed gas in pressurized tanks. Due to the low-energy density of hydrogen, it is difficult to store enough hydrogen on-board to allow vehicles to travel the same distance as gasoline-powered vehicles before refueling, typically 300400 miles. Higher-density liquid fuels, such as methanol, ethanol, natural gas, liquefied petroleum gas, and gasoline, can be used for fuel, but the vehicles must have an onboard fuel processor to reform the methanol to hydrogen. This requirement increases costs and maintenance. The reformer also releases carbon dioxide (a greenhouse gas), though less than that emitted from current gasoline-powered engines. Direct Methanol Fuel Cells Most fuel cells are powered by hydrogen, which can be fed to the fuel cell system directly or can be generated within the fuel cell system by reforming hydrogen-rich fuels such as methanol, ethanol, and hydrocarbon fuels. Direct methanol fuel cells (DMFCs), however, are powered by pure methanol, which is mixed with steam and fed directly to the fuel cell anode. Direct methanol fuel cells do not have many of the fuel storage problems typical of some fuel cells because methanol has a higher energy density than hydrogenthough less than gasoline or diesel fuel. Methanol is also easier to transport and supply to the public using our current infrastructure because it is a liquid, like gasoline. Direct methanol fuel cell technology is relatively new compared with that of fuel cells powered by pure hydrogen, and DMFC research and development is roughly 34 years behind that for other fuel cell types.

DEPT. OF EEE

MEA ENGG COLLEGE PMNA

HYDROGEN FUTURE OF ENERGY STORAGE

26

Alkaline Fuel Cells

Fig:5 alkaline fuel cell Alkaline fuel cells (AFCs) were one of the first fuel cell technologies developed, and they were the first type widely used in the U.S. space program to produce electrical energy and water on-board spacecrafts. These fuel cells use a solution of potassium hydroxide in water as the electrolyte and can use a variety of non-precious metals as a catalyst at the anode and cathode. High-temperature AFCs operate at temperatures between 100C and 250C (212F and 482F). However, newer AFC designs operate at lower temperatures of roughly 23C to 70C (74F to 158F) AFCs' high performance is due to the rate at which chemical reactions take place in the cell. They have also demonstrated efficiencies near 60% in space applications. The disadvantage of this fuel cell type is that it is easily poisoned by carbon dioxide (CO2). In fact, even the small amount of CO2 in the air can affect this cell's operation, making it necessary to purify both the hydrogen and oxygen used in the cell. This purification process is costly. Susceptibility to poisoning also affects the cell's lifetime (the amount of time before it must be replaced), further adding to cost.

DEPT. OF EEE

MEA ENGG COLLEGE PMNA

HYDROGEN FUTURE OF ENERGY STORAGE

27

Cost is less of a factor for remote locations, such as space or under the sea. However, to effectively compete in most mainstream commercial markets, these fuel cells will have to become more cost-effective. AFC stacks have been shown to maintain sufficiently stable operation for more than 8,000 operating hours. To be economically viable in large-scale utility applications, these fuel cells need to reach operating times exceeding 40,000 hours, something that has not yet been achieved due to material durability issues. This obstacle is possibly the most significant in commercializing this fuel cell technology.

Phosphoric Acid Fuel Cells

Phosphoric acid fuel cells use liquid phosphoric acid as an electrolytethe acid is contained in a Teflon-bonded silicon carbide matrixand porous carbon electrodes containing a platinum catalyst. The chemical reactions that take place in the cell are shown in the diagram to the right. fuel cell The phosphoric acid fuel cell (PAFC) is considered the "first generation" of modern fuel cells. It is one of the most mature cell types and the first to be used commercially. This type of fuel cell is typically used for stationary power generation, but some PAFCs have been used to power large vehicles such as city buses. PAFCs are more tolerant of impurities in fossil fuels that have been reformed into hydrogen than PEM cells, which are easily "poisoned" by carbon monoxide
DEPT. OF EEE MEA ENGG COLLEGE PMNA

Fig:6 PAFC

HYDROGEN FUTURE OF ENERGY STORAGE

28

because carbon monoxide binds to the platinum catalyst at the anode, decreasing the fuel cell's efficiency. They are 85% efficient when used for the co-generation of electricity and heat but less efficient at generating electricity alone (37%42%). This is only slightly more efficient than combustion-based power plants, which typically operate at 33%35% efficiency. PAFCs are also less powerful than other fuel cells, given the same weight and volume. As a result, these fuel cells are typically large and heavy. PAFCs are also expensive. Like PEM fuel cells, PAFCs require an expensive platinum catalyst, which raises the cost of the fuel cell. Molten Carbonate Fuel Cells

Molten carbonate fuel cells (MCFCs) are currently being

developed for natural gas and coalbased power plants for electrical utility, industrial, and military applications. MCFCs are high-temperature fuel cells that use an electrolyte composed of a molten carbonate salt mixture

suspended in a porous, chemically inert ceramic lithium aluminum oxide

(LiAlO2) matrix. Because they operate at extremely high temperatures of Fig:7 molten carbonate fuel cell 650C (roughly 1,200F) and above, non-precious metals can be used as catalysts at the anode and cathode, reducing costs. Improved efficiency is another reason MCFCs offer significant cost reductions over phosphoric acid fuel cells (PAFCs). Molten carbonate fuel cells, when coupled with a turbine, can reach efficiencies approaching 65%, considerably
DEPT. OF EEE MEA ENGG COLLEGE PMNA

HYDROGEN FUTURE OF ENERGY STORAGE

29

higher than the 37%42% efficiencies of a phosphoric acid fuel cell plant. When the waste heat is captured and used, overall fuel efficiencies can be as high as 85%. Unlike alkaline, phosphoric acid, and polymer electrolyte membrane fuel cells, MCFCs do not require an external reformer to convert more energy-dense fuels to hydrogen. Due to the high temperatures at which MCFCs operate, these fuels are converted to hydrogen within the fuel cell itself by a process called internal reforming, which also reduces cost. Molten carbonate fuel cells are not prone to carbon monoxide or carbon dioxide "poisoning" they can even use carbon oxides as fuelmaking them more attractive for fueling with gases made from coal. Because they are more resistant to impurities than other fuel cell types, scientists believe that they could even be capable of internal reforming of coal, assuming they can be made resistant to impurities such as sulfur and particulates that result from converting coal, a dirtier fossil fuel source than many others, into hydrogen. The primary disadvantage of current MCFC technology is durability. The high temperatures at which these cells operate and the corrosive electrolyte used accelerate component breakdown and corrosion, decreasing cell life. Scientists are currently exploring corrosion-resistant materials for components as well as fuel cell designs that increase cell life without decreasing performance. Solid Oxide Fuel Cells

DEPT. OF EEE

MEA ENGG COLLEGE PMNA

HYDROGEN FUTURE OF ENERGY STORAGE

30

Fig:8 SOFC fuel cell Solid oxide fuel cells (SOFCs) use a hard, non-porous ceramic compound as the electrolyte. Because the electrolyte is a solid, the cells do not have to be constructed in the plate-like configuration typical of other fuel cell types. SOFCs are expected to be around 50%60% efficient at converting fuel to electricity. In applications designed to capture and utilize the system's waste heat (co-generation), overall fuel use efficiencies could top 80%85%. Solid oxide fuel cells operate at very high temperaturesaround 1,000C (1,830F). High-temperature operation removes the need for precious-metal catalyst, thereby reducing cost. It also allows SOFCs to reform fuels internally, which enables the use of a variety of fuels and reduces the cost associated with adding a reformer to the system. SOFCs are also the most sulfur-resistant fuel cell type; they can tolerate several orders of magnitude more of sulfur than other cell types. In addition, they are not poisoned by carbon monoxide (CO), which can even be used as fuel. This property allows SOFCs to use gases made from coal. High-temperature operation has disadvantages. It results in a slow startup and requires significant thermal shielding to retain heat and protect personnel, which may be acceptable for utility applications but not for transportation and small portable applications. The high operating temperatures also place stringent durability requirements on materials. The development of low-cost materials with high durability at cell operating temperatures is the key technical challenge facing this technology. Scientists are currently exploring the potential for developing lowertemperature SOFCs operating at or below 800C that have fewer durability problems and cost less. Lower-temperature SOFCs produce less electrical power, however, and stack materials that will function in this lower temperature range have not been identified.
DEPT. OF EEE MEA ENGG COLLEGE PMNA

HYDROGEN FUTURE OF ENERGY STORAGE

31

Regenerative Fuel Cells Regenerative fuel cells produce electricity from hydrogen and oxygen and generate heat and water as byproducts, just like other fuel cells. However, regenerative fuel cell systems can also use electricity from solar power or some other source to divide the excess water into oxygen and hydrogen fuelthis process is called "electrolysis." This is a comparatively young fuel cell technology being developed by NASA and others. 4.7 STORAGE SYSTEMS TO ADDRESS ELECTRICITY SUPPLY INTERMITTENCY

Storage elements are integrated with RES systems in many ways using power electronic switching converters [6-7]. Figure 2 shows how one storage system is incorporated to regulate the voltage and power of transmission lines carrying power from RES energy stream. The storage element is incorporated within a unified power flow controller (UPFC) made of controlled switching
DEPT. OF EEE MEA ENGG COLLEGE PMNA

HYDROGEN FUTURE OF ENERGY STORAGE

32

converters. The storage element could be a capacitor or a battery. UPFC basically consists of two fully controlled static converters sharing a common DC link. The DC link voltage is maintained constant by the storage element potential. The converters are controlled to compensate for the voltage as well as the power of the coupled transmission lines. Converter 2 performs the main function of the UPFC by injecting an AC voltage with controllable magnitude and phase angle in series with the transmission line The AC injected voltage is supplied from the storage element whenever the incoming supply fluctuates below the nominal value. Converter 1 supplies or absorbs the active power demanded by Converter 2. Both converters can be controlled to generate or absorb controllable reactive power or provide independent shunt reactive compensation for the line. The stored energy is continuously replenished by converter 1 and released when requested through converter 2. . Interfacing storage element with transmission lines for voltage and power

compensation .A second system that incorporates a storage element to regulate the intermittency of small and diverse generating units such as wind and biogas micro turbine. The storage element could be a capacitor or a battery supported by hydrogen powered fuel cells. The stored energy is controlled via a power switching converter and is connected to the RES distributed generation units. Here the storage element and the converter are interfaced with the uncompensated distribution feeder at the local connection point. The converter is designed to channel the stored energy to supply power to the grid during the interruption moments. The converter can be used to mitigate short duration power surges, voltage dip and brownout events and maintain continuous supply regardless of the incoming source state.

Interfacing storage element with RES system for voltage and power compensation

DEPT. OF EEE

MEA ENGG COLLEGE PMNA

HYDROGEN FUTURE OF ENERGY STORAGE

33

4.8 SIMULATION OF THE BUFFERING PROCESS The imbalance (or difference) between (e.g. wind power) supply and demand can vary significantly. Here it is assumed that (with the help of permanently updated weather and load forecasts) the mean imbalance can be predicted sufficiently well for timescales of about a minute (in less favorable cases it may be a few minutes). But momentary fluctuations of the imbalance can still be significant, especially during phases of strong wind power supply. Arbitrary 24-hour imbalance curves which also include windless phases, were created. Simple control algorithms for the hybrid energy storage system were tested as regards their usefulness for buffering these imbalances. The forecasted mean imbalance is used to define the operating conditions for the slow EES which consists of modular electrolyzer and fuel cell blocks. For a positive imbalance the electrolyzer blocks produce H2 whereas for a negative one H2 is used-up in the fuel cell blocks. If the EES system is operated too far away from this mean imbalance, then the H2 system can be adapted by switching an additional block on or off. The algorithm also takes into account the current charging status of the SMES i.e. whether the currently stored energy is below or above certain thresholds (20% and 80% of the storage capacity). Below the lower threshold, the EES operating level is increased by either increasing the number of active electrolyzer blocks by one (for a positive imbalance), or by decreasing the number of active fuel cell blocks by one (for a negative imbalance). Accordingly, the EES operating level the operational level of the H2 part is then compensated by the faster (and more efficient) SMES. The control of the thresholds then ensures that the SMES can take up or deliver short term power at any time.

DEPT. OF EEE

MEA ENGG COLLEGE PMNA

HYDROGEN FUTURE OF ENERGY STORAGE

34

CHAPTER 5 COMPARISON
5.1 Cost comparison The costs of energy storage technologies for distributed generation (DG) are displayed in Table I. In a system, there are many kinds of costs, used for setting up, running, fixing, replacement, revenue, etc. The capital cost is the setting up fee.

table:1 cost comparison 5.2 Other Comparisons Flywheels, NaS batteries, and hydrogen storage methods including water electrolysis, compressed gas, and fuel cell, are compared in Table II from several aspects in terms of energy losses, efficiencies, costs, response times, and lifetimes, etc, to find out an optimum way for micro-grid application. Flywheels are mature technologies that are used commercially. Hydrogen storage is quite a new technology in this area. It is a good candidate chosen in this application for it is suitable for large scale, long storage time and reduced environmental impact. In the hydrogen storage application, efficiency is the whole hydrogen storage systems, the loss only stands for the compressed gas process, and the other aspects for it presented in the table below are the lowest level during the three
DEPT. OF EEE MEA ENGG COLLEGE PMNA

HYDROGEN FUTURE OF ENERGY STORAGE

35

Unitswater electrolysis, compressed gas, and fuel cell. From Table II, we can only see the hydrogen storage method has the lowest efficiency, shortest replacement period and high cost, etc. Actually, only the fuel cell part contributes it. Hydrogen combustion cell instead of it will be investigated to improve it in later research.

DEPT. OF EEE

MEA ENGG COLLEGE PMNA

HYDROGEN FUTURE OF ENERGY STORAGE

36

Table:2 other comparison

DEPT. OF EEE

MEA ENGG COLLEGE PMNA

HYDROGEN FUTURE OF ENERGY STORAGE

37

CHAPTER6 CONCLUSION
A new wind power design methodology that identifies the optimal use of hydrogen energy storage in order to balance the electricity production to load demand has been described. Different hydrogen storage methods were carefully compared and the compressed gas approach was chosen as the best solution for this study due to its relatively high conversion efficiency, easy operation and low leakage rate. The Methodology was tested using a case study based on the wind and load data for University of Bath, UK. The results showed that the electricity demands can be met entirely locally by the equivalent of a 48.4 m radius wind turbine in conjunction with a compressed hydrogen energy storage and recovery system with a 2000 m3 capacity. The storage size was calculated using the minimum of the integrated energy balance curve for a complete annual cycle of data and identifying the maximum depth of storage capacity from this. The size of the wind turbine required depends on the size of storage size. It has been shown that, for this case study, a wind turbine of 48.4 m ensures that the micro-grid becomes self sufficient with hydrogen storage. There are further studies that need to be performed in the future work for this research. The method needs to be extended to include more dynamic storage models, where the energy leaks over time as shown in Figure 4. The method should also use multi-year data to get a more sustainable and accurate design for the renewable energy installation. Neither of these extensions to the work is incompatible with the approach taken so far. Hydrogen energy storage to provide off-grid renewable energy smoothing certainly seems practical when optimized using the methodology described within this pape

DEPT. OF EEE

MEA ENGG COLLEGE PMNA

HYDROGEN FUTURE OF ENERGY STORAGE

38

REFERENCES
IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, VOL. 21, NO. 3, JUNE 2011 UPEC2010 31st Aug - 3rd Sept 2010(Shuang YuEE, University of Bath [email protected] Tim J. Mays CE, University of Bath [email protected] Roderick W. Dunn EE, University of Bath [email protected] Ulleberg, T. Nakken, and A. Et, "The wind/hydrogen demonstration system at Utsira in Norway: Evaluation of system performance using operational data and updated hydrogen energy system modeling tools," International Journal of Hydrogen Energy, 2010. UPI, "German plant mixes renewables and hydrogen," 2009. IEEE TRANSACTIONS ON ENERGY CONVERSION, VOL. 19, NO. 3, SEPTEMBER 2004

DEPT. OF EEE

MEA ENGG COLLEGE PMNA

You might also like