Xmesh Moteconfig User Manual 7430-0112-02 - A-T
Xmesh Moteconfig User Manual 7430-0112-02 - A-T
MEMSIC, Inc., 1759 McCarthy Blvd, Milpitas, CA 95035 Tel: 408-964-9700, Fax: 408-854-7702 email: [email protected], website: www.memsic.com
2010 MEMSIC, Inc. All rights reserved. Information in this document is subject to change without notice. MEMSIC, MoteWorks, MICA, TrueMesh and XMesh are registered trademarks of MEMSIC, Inc. Other product and trade names are trademarks or registered trademarks of their respective holders
Table of Contents
Introduction.............................................................................................................................1
1.1 1.2 MoteConfig ....................................................................................................................1 Over The Air Programming (OTAP) ....................................................................1
Installation...............................................................................................................................3
2.1 2.2 2.3 Supported Platforms .......................................................................................................3 PC Interface Port Requirements .....................................................................................3 Installation Steps ............................................................................................................4
3 4
Page i
; NOTE
Note provides additional information about the topic.
; EXAMPLE
Examples are given throughout the manual to help the reader understand the terminology.
3 IMPORTANT
This symbol defines items that have significant meaning to the user
0 WARNING
The user should pay particular attention to this symbol. It means there is a chance that physical harm could happen to either the person or the equipment. The following paragraph heading formatting is used in this manual:
1 Heading 1
1.1 Heading 2 1.1.1 Heading 3
This document also uses different body text fonts (listed in Table 0-1) to help you distinguish between names of files, commands to be typed, and output coming from the computer.
Table 0-1. Font types used in this document. Font Type Courier New Normal Courier New Bold Franklin Medium Condensed Usage Sample code and screen output Commands to be typed by the user Text labels in GUIs
Page ii
1
1.1 MoteConfig
Introduction
MoteConfig is a Windows-based GUI utility for programming Motes. This utility provides an interface for configuring and downloading pre-compiled XMesh/TinyOS firmware applications onto Motes. MoteConfig allows the user to configure the Mote ID, Group ID, RF channel and RF power. The user can also enable the over-the-air-programming feature present on all XMesh - based firmware. High-power and low-power XMesh applications are available for each sensor board and platform manufactured by MEMSIC as part of the MoteView install (see section 2.3).
Table 1-1. Pre-compiled MICAz XMesh applications MICAz Mote (MPR2400 and MPR2600)
Board Model MTS101 MTS300CA MTS300CB MTS310CA MTS310CB MTS400 MTS410 MTS420 MTS450 MDA100CA MDA100CB XBW-DA100CA XBW-DA100CB MDA300 MDA300 (precision) MDA320 XBW-DA325 Binary file name MTS boards XMTS101_2420_<mode>.exe XMTS300CA_2420_<mode>.exe XMTS300CB_2420_<mode>.exe XMTS310CA_2420_<mode>.exe XMTS310CB_2420_<mode>.exe XMTS400_2420_<mode>.exe XMTS410_2420_<mode>.exe XMTS420_2420_hp.exe XMTS450_2420_<mode>.exe MDA board XMDA100CA_2420_<mode>.exe XMDA100CB_2420_<mode>.exe XBW-DA100CA_2420_hp.exe XBW-DA100CB_2420_hp.exe XMDA300_2420_<mode>.exe XMDA300p_2420_<mode>.exe XMDA320_2420_<mode>.exe XBW-DA325_2420_<mode>.exe
Base Station (common to all boards) XMeshBase_2420_<mode>.exe <mode> = hp or lp. hp = high power mesh networking. lp = low-power mesh networking via low-power listening and time synchronized data transmissions.
1.2
The Over-The-Air-Programming (OTAP) feature allows users to reprogram a Mote over a wireless link. OTAP allows one or more Motes in the XMesh network to receive new firmware images from XServe (via the XOtap service).
Doc.# 7430-0112-02 Rev. A Page 1
Each Mote has a 512kB external non-volatile flash divided into 4 slots. These slots have a default size of 128 kB. Slot 0 is reserved for the OTAP image. Slots 1, 2 and 3 can be used for userspecified firmware. During the OTAP process, the server sends a command to the Mote to reboot into the OTAP image (slot 0). A user-specified firmware image is broken up into fragments and transmitted to the Mote and stored into Slot 1, 2 or 3. The server can send a message to transfer the newly uploaded firmware into the program flash and reboot the Mote. The following components are required for OTAP to work: XServe and XOtap running on the server Firmware applications that include the XOTAPLiteM component (this is automatically included when the firmware is built with XMesh) The Mote needs to have pre-configured with a bootloader in the program flash, and the OTAP image in slot 0 of the external flash. Both of these conditions are met by selecting OTAP enable during the MoteConfig download process outlined in Section 4.
Page 2
2
2.1 Supported Platforms Windows XP Home Window XP Professional Windows 2000 with SP4 2.2 PC Interface Port Requirements
Installation
The gateway platform used in the base station determines the PC interface port required by MoteConfig. 1. For a MIB510 serial gateway: an RS-232 serial port. 2. For a MIB520 USB gateway: a USB port. 3. For a MIB600 Ethernet gateway: A wired Ethernet or 802.11 wireless card (if the MIB600 is on a LAN with wireless access).
Page 3
2.3
Installation Steps
MoteConfig is shipped as a component of MoteView and MoteWorks: 1. MoteConfig is automatically installed with the MoteView installer. Refer to the MoteView Users Manual for additional details. 2. MoteConfig is an optional component in the MoteWorks installer. Make sure that MoteConfig 2.0 and OTAP item is selected as shown in Figure 2-1.
Page 4
3
-
Starting MoteConfig
If MoteConfig was installed using the MoteView installer, use the following steps: Open MoteView by either clicking on the shortcut located on the Desktop, or by going to Start > Programs>MEMSIC>MoteView. Press the Program Mote button ( as shown in Figure 3-1 ) on the MoteView toolbar to spawn the MoteConfig GUI
If MoteConfig was installed using the MoteWorks installer Click on the shortcut located on the Desktop, or select Start > Programs>MEMSIC> MoteConfig2.0.
Page 5
Local Programming
The Local Program tab is used to upload firmware onto the Motes via a gateway.
Click on Settings > Interface Board... to select the correct gateway and port settings. Figure 4-1 shows the Interface Board Settings for a MIB510 on COM 1.
The MIB520 virtual COM port drivers will install two sequential ports on the PC. The lownumbered port is used for programming and the high-numbered port is used for communication. Figure 4-2 shows the Interface Board Settings for a MIB520 that has created COM 6 and 7 on the PC. In this example, COM 6 must be selected as the serial port.
; NOTE:
The MIB520 requires the installation of the FTDI FT2232C drivers. Once these drivers are installed, the Device Manager (Start > Control Panel > System > Hardware) will display the MIB520 as two new virtual com ports. Refer to the MPR-MIB Series Users Manual for details.
Page 6 Doc.# 7430-0112-02 Rev. A
Figure 4-3 shows the Interface Board Settings for a MIB600 on the same LAN as the PC with an assigned IP address of 10.1.1.99.
; NOTE:
The IP address of the MIB600 can be identified by using the Lantronix DeviceInstaller application. Refer to the MPR-MIB Series Users Manual for details.
4.2
Programming
The pre-compiled XMesh applications installed with MoteView are located in C > Program Files > MEMSIC > MoteView > XMesh. Press the Select button to open a file browser as shown in Figure 4-4. Navigate to the folder that corresponds to your Mote processor/radio board, radio frequency (for MICA2 and MICA2DOT) and sensor board type.
Low-power and high-power applications have been included for most sensor boards. Note that the MEP and MSP node firmware is located in separate named folders.
Doc.# 7430-0112-02 Rev. A Page 7
; NOTE: The base station Mote must be programmed with XMeshBase_xxx_<mode>.exe and a
node ID of 0. After an application has been selected, the binary scan feature built into MoteConfig will display the default parameters programmed into the application (see Figure 4-5).
These default parameters can be overwritten by the user by specifying the desired MOTE ID, GROUP ID, RF Power, and RF Channel.
Page 8
The table below describes the advanced options available in the MoteConfig GUI.
Doc.# 7430-0112-02 Rev. A Page 9
4.3
Fuse Settings
MoteConfig allows users to overwrite the default fuse settings of the ATmega128 processor. The fuses are an internal set of software switches within the ATmega128 that enable certain functions. Select Settings > Fuse Defaults to open the dialog box shown in Figure 4-8. Check Override default fuse settings to modify the available fuse options. These options are:
JTAG fuse on activates the JTAG debug mode for the ATmega128. When enabled, the
processor draws an additional current of 3 mA. By default, this fuse is turned off for all XMesh apps. External oscillator on forces the firmware app to use an external oscillator for its timer. When enabled, the processor draws more current. By default, this fuse is disabled for low power XMesh apps and enabled for high power XMesh apps. Disable bootloader will prevent the Mote from executing the boot loader code on reboot. By
default, the bootloader is enabled for XMesh apps to provide OTAP functionality.
4.4
The default behavior associated with setting the Group ID, RF Power and RF Channel for each node can be changed from the Address and Radio Defaults dialog shown in Figure 4-9. This can be opened be selecting Settings > Address and Radio Defaults
Page 10
When a new firmware application is selected, the default values for the Group ID, RF Power and RF Channel will: remain unchanged (from the previous settings) be replaced by values read from the firmware application (using the firmware scan)
Page 11
The Over-The-Air-Programming (OTAP) feature allows users to reprogram a Mote over a wireless channel. OTAP allows one or more Motes in the XMesh network to receive new firmware images from XServe (via the XOtap service).
; NOTE: OTAP is currently available only when the Motes are programmed with a high power
firmware application(i.e. XMTS310CB_433_hp.exe). 5.1 OTAP Preparation Before Motes can be programmed over the air, they must be prepared by enabling the bootloader and loading the OTAP image into slot 0. This procedure is outlined in the following steps: 1. From Settings>Interface Board select the appropriate interface board and specify the correct COM port number.
2. Switch to the Local Program tab and click Select to browse to an XMesh application. Choose the appropriate MOTE ID, GROUP ID, RF Power, and RF Channel. Make sure that the OTAP Enable box is checked. Click on Program.
Page 12
3. Repeat Step 2 for all the nodes in the network. When the bootloader has successfully installed, the LEDs will count up twice when the node is switched on. 4. Program the base station Mote with the XMeshBase application and set Node ID to 0. For the base firmware the OTAP Enable box should be unchecked.
Page 13
Figure 5-3: Programming the XMeshBase application onto the base station.
5.2
Over-the-Air-Programming
Once all the Motes are OTAP-enabled, use the following procedure to program them over a wireless link.
; IMPORTANT: Please make sure that the Mote battery power is above 2.7V before starting
the OTAP procedure. 1. Connect the base node to the PC interface board and turn on the remote nodes that were prepared as shown in section 5.1. 2. Switch to the Remote Program tab. 3. Click on the Search button to start up XServe and listen for remote nodes. The Motes found within the network will be displayed in the tree-view control as shown in Figure 5-4.
Page 14
; NOTE: The base node will periodically blink with a magenta background. This indicates that
heartbeat packets sent by the base firmware are being received by the PC. This verifies that the base station has been correctly configured.
Page 15
4. The Motes can now be rebooted to the OTAP image (OtapGold.exe) by selecting nodes from the tree-view control and pressing the Prepare button. Nodes can also be selected by entering their IDs into the Select Nodes textbox. During this process, the Prepare button will be disabled and the selected node will turn blue.
; NOTE: The node IDs entered in the Select Nodes textbox override the node selection in the
tree-view control.
When the nodes have rebooted into the OTAP image, their background color will turn gold as shown in Figure 5-5.
Page 16
5. When the nodes are running the OTAP image, a) The Query button allows users to see the available slots and their contents on each Mote as shown in Figure 5-6.
b) The Program button can be used to load firmware images into a selected slot on one or more selected nodes using the following procedure 1. Select the firmware application, as shown in Figure 5-7 2. Specify the slot to store the firmware application 3. Choose the nodes by checking the nodes in the tree-view or by entering the node IDs in the Select Nodes textbox 4. Press Program
; IMPORTANT: If nodes are specified in the Select Nodes textbox, the OTAP operations will
only occur on these nodes; the nodes checked on the tree-view will be ignored. The Select Nodes textbox is an advanced feature and should be used with care.
Page 17
Page 18
During the OTAP process, the color of the selected nodes will turn orange as shown in Figure 5-8 and the status message area will display how the number of pages downloaded into the external flash. When the selected nodes have been successfully programmed, the node will turn gold once again.
Open the Process Messages window (by clicking on File > View Process Details) to trace all downloading steps as shown in Figure 5-9.
Page 19
3.
Press reboot
Page 20
The selected nodes will turn green (as shown in Figure 5-11) when they have successfully rebooted, re-joined the wireless mesh and sent health packets to Xserve. The nodes will now be executing the newly uploaded firmware application.
Page 21
Click Settings > OTAP Timeout to open the Set Timeout dialog shown in Figure 5-12. The default values were derived by testing with a small network of about 30 nodes. If your mesh network contains more than 30 nodes, please reset the relevant values or leave the timeout check disabled.
To enable or disable the base heartbeat timeout or OTAP operation timeout, use the checkboxes located on the Remote Program tab of the MoteConfig application.