0% found this document useful (0 votes)
486 views

Frangible Roof

The document contains calculations for determining the frangible design of roofs according to API 650 Section 5.10.2.6.a.5. It provides parameters such as internal design pressure, actual roof area, yield strength, roof slope, weight of roof and shell components, and calculates the maximum allowable participation area and design pressure for four different roof designs. The calculations show that in each case, the actual roof area is less than the maximum allowable area for a frangible roof design.

Uploaded by

amevaluaciones
Copyright
© Attribution Non-Commercial (BY-NC)
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
486 views

Frangible Roof

The document contains calculations for determining the frangible design of roofs according to API 650 Section 5.10.2.6.a.5. It provides parameters such as internal design pressure, actual roof area, yield strength, roof slope, weight of roof and shell components, and calculates the maximum allowable participation area and design pressure for four different roof designs. The calculations show that in each case, the actual roof area is less than the maximum allowable area for a frangible roof design.

Uploaded by

amevaluaciones
Copyright
© Attribution Non-Commercial (BY-NC)
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 8

FRANGIBLE ROOF DESIGN PER API 650 SECTION 5.10.2.6.a.

5 AD
P= A= Fy= Tan= DLR= D= DLS= 10 3.948 36000 0.1667 15542 49.3 160049
Internal design pressure (in. of water) Actual Part. Area due Roof-to -Shell (in2) Slope of the roof, expressed as a decimal quantity Nominal weight of roof plate plus any attached structural (lbf). Diamter in Nominal weight of the shell and any framing (but not roof plates) supported by

Lowest minimum specified yield strength (modified for design temperature) of t

P_F4.1
2 2 P_F41= (0,962)(AFY)(Tan)/(D )+(0.245*DLR)/D = 10.9443789 in H2O = 0.39399764 psi

Afr= Maximun Participation Area for Frangible Roof = DLS/(2*PI*Fy*Tan) = 4.24462678 In2 Area actual 3,948 in2 < < Area frangible Afr 4,244 in2

50 SECTION 5.10.2.6.a.5 ADDENDUM 3 -2011

ngth (modified for design temperature) of the materials in the roof-to-shell junction (lb/in.2) attached structural (lbf).

raming (but not roof plates) supported by the shell and roof (lbf)

2 12 0.16666667 157037 3012 160049

r Frangible Roof

ea frangible Afr

FRANGIBLE ROOF DESIGN PER API 650 SECTION 5.10.2.6.a.5 AD


P= A= Fy= Tan= DLR= D= DLS= 10 3.633 36000 0.1667 15542 45.93 140764
Internal design pressure (in. of water) Actual Part. Area due Roof-to -Shell (in2) Slope of the roof, expressed as a decimal quantity Nominal weight of roof plate plus any attached structural (lbf). Diamter in Nominal weight of the shell and any framing (but not roof plates) supported by

Lowest minimum specified yield strength (modified for design temperature) of t

P_F4.1
2 2 P_F41= (0,962)(AFY)(Tan)/(D )+(0.245*DLR)/D = 11.7472849 in H2O = 0.42290226 psi

Afr= Maximun Participation Area for Frangible Roof = DLS/(2*PI*Fy*Tan) = 3.73317324 In2 Area actual 3,633 in2 < < Area frangible Afr 3,733 in2

50 SECTION 5.10.2.6.a.5 ADDENDUM 3 -2011

ngth (modified for design temperature) of the materials in the roof-to-shell junction (lb/in.2) attached structural (lbf).

raming (but not roof plates) supported by the shell and roof (lbf)

2 12 0.16666667 138419 2345 140764

r Frangible Roof

ea frangible Afr

FRANGIBLE ROOF DESIGN PER API 650 SECTION 5.10.2.6.a.5 AD


P= A= Fy= Tan= DLR= D= DLS= 10 2.3 36000 0.1125 15542 31.22 60986
Internal design pressure (in. of water) Actual Part. Area due Roof-to -Shell (in2) Slope of the roof, expressed as a decimal quantity Nominal weight of roof plate plus any attached structural (lbf). Diamter in Nominal weight of the shell and any framing (but not roof plates) supported by

Lowest minimum specified yield strength (modified for design temperature) of t

P_F4.1 P_F41= (0,962)(AFY)(Tan)/(D )+(0.245*DLR)/D = 13.1004124 in H2O = 0.47161485 psi


2 2

Afr= Maximun Participation Area for Frangible Roof = DLS/(2*PI*Fy*Tan) = 2.39662327 In2 Area actual 2,3 in2 < < Area frangible Afr 2,397 in2

50 SECTION 5.10.2.6.a.5 ADDENDUM 3 -2011

ngth (modified for design temperature) of the materials in the roof-to-shell junction (lb/in.2) attached structural (lbf).

raming (but not roof plates) supported by the shell and roof (lbf)

1.35 12 0.1125

r Frangible Roof

59804 1182 60986

ea frangible Afr

FRANGIBLE ROOF DESIGN PER API 650 SECTION 5.10.2.6.a.5 AD


P= A= Fy= Tan= DLR= D= DLS= 10 2.439 36000 0.1041 5893 31.25 72006
Internal design pressure (in. of water) Actual Part. Area due Roof-to -Shell (in2) Slope of the roof, expressed as a decimal quantity Nominal weight of roof plate plus any attached structural (lbf). Diamter in Nominal weight of the shell and any framing (but not roof plates) supported by

Lowest minimum specified yield strength (modified for design temperature) of t

P_F4.1
2 2 P_F41= (0,962)(AFY)(Tan)/(D )+(0.245*DLR)/D = 10.4825306 in H2O = 0.3773711 psi

Afr= Maximun Participation Area for Frangible Roof = DLS/(2*PI*Fy*Tan) = 3.05801845 In2 Area actual 2,439 in2 < < Area frangible Afr 3,058 in2

50 SECTION 5.10.2.6.a.5 ADDENDUM 3 -2011

ngth (modified for design temperature) of the materials in the roof-to-shell junction (lb/in.2) attached structural (lbf).

raming (but not roof plates) supported by the shell and roof (lbf)

1.25 12 0.10416667

r Frangible Roof

71061 945 72006

ea frangible Afr