0% found this document useful (0 votes)
292 views168 pages

48 50p-7pd

Carrier's 48 / 50P Series commercial packaged rooftop units offer design flexibility, quality, reliability, interoperability and ComfortLink controls. All 48/50P Series units may also be applied to non-residential applications. 48/50 Series units are available with puron(r) refrigerant (r-410a) and novation(r) heat exchanger technology.

Uploaded by

mansidev
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
292 views168 pages

48 50p-7pd

Carrier's 48 / 50P Series commercial packaged rooftop units offer design flexibility, quality, reliability, interoperability and ComfortLink controls. All 48/50P Series units may also be applied to non-residential applications. 48/50 Series units are available with puron(r) refrigerant (r-410a) and novation(r) heat exchanger technology.

Uploaded by

mansidev
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 168

Product

Data

WEATHERMASTER
48/50P2,P3,P4,P5030-100
Single-Package Gas Heating/Electric
Cooling Rooftop Units
and Electric Cooling Rooftop Units
with Optional Electric Heat
with ComfortLink Controls
and PURON Refrigerant (R-410A)
30 to 100 Nominal Tons

Carriers 48/50P Series commercial


packaged rooftops offer:
Puron refrigerant (R-410A)
Novation heat exchanger
technology with microchannel coil
scroll compressors
digital scroll compressor option
constant volume (CV)
staged air volume (SAV)
variable air volume (VAV)
vertical supply/return units
horizontal supply/return units
flexible chassis and plenum options
optional return fan/modulating power
exhaust
optional high-capacity modulating
power exhaust
staged gas control option for supply
air tempering
optional modulating gas heat
hydronic heat option
high-capacity evaporator coil
optional airfoil fan
Humidi-MiZer adaptive dehumidification option

Features/Benefits
Carriers 48/50P commercial
packaged unit offers design
flexibility, quality, reliability,
interoperability and
ComfortLink controls.
ComfortLink controls

a48-8424

Carrier Corporation 2013

Factory-installed ComfortLink controls


provide the capability for free standing
operation or may be linked with a more
extensive system. Factory-installed and
programmed BACnet* communication
capability provides simple integration
with the building HVAC system (e.g.,
terminal devices), an i-Vu Open control
system or a BACnet building automation
system.
Form 48/50P-7PD

Features/Benefits (cont)
ComfortLink controls also have the
capability to communicate with the
Carrier Comfort Network (CCN) system. This communication flexibility allows simple system integration as well
as data collection, trending, monitoring
and alarm displays.
The 48/50P Series may also be configured to communicate via MODBUS or LonWorks** protocols if required by the application.
The ComfortLink controls can also
interface directly with BACnet or CCN
controls on 35 and 45 Series VAV terminals to form a system for optimal efficiency and tenant comfort.
All units may also be applied to noncommunicating building control systems via switch and/or 4 to 20 mA signal to provide remote occupancy control, fire shutdown and smoke control
modes, IAQ (indoor air quality) modes,
and demand limit sequences.
In addition, VAV units can interface
with other control systems via a 4 to
20 mA signal capability which permits
control of supply-air temperature reset.
Standard ComfortLink controls
functions include:
easy to use plain English display
supply-fan control based on occupancy schedule
up to 6 steps of capacity control
with standard scroll compressors
digital scroll compressor option
allows variable control of compressor capacity to match load requirement of the space
lead-lag circuit control to equalize
the operating hours between the
dual refrigeration circuits
2-stage heat control
adaptive optimal start/morning
warm-up

adaptive optimal stop (CV only)


head pressure control to 32 F ambient outdoor-air temperature
economizer and ventilation control
economizer sequence enabled by
standard outside air enthalpy switch
adjustment of space set point in the
occupied space on CV applications
selectable supply air set point in
both CV, SAV, and VAV modes
control of optional variable frequency supply-fan drives
interface with 35 or 45 Series VAV
terminals to create a system
IAQ and demand controlled ventilation control support
space temperature reset (VAV
applications)
local or remote unit alarm and alert
monitoring
filter maintenance alarm
building ventilation mode purge
self-monitoring diagnostics
demand limiting
external input to permit supply-air
temperature reset using a 4 to
20 mA signal from another control
system
A self-diagnostic microprocessor manages all unit sequences, including stages of cooling and unit safety controls.
The microprocessor also controls stages of cooling and unit safety controls.
At start-up, the self-diagnostic test verifies component operation and calibration. Fault codes and expanded fault
descriptions reduce service troubleshooting time and difficulty.

configured in the factory, based on the


unit model and options installed.
System functions like adaptive optimal start, nighttime free cooling,
building smoke control modes, occupied heating and IAQ support are resident in the controls and can be easily
integrated into the control system
strategy.

Environmentally sound
Carriers Puron refrigerant (R-410A)
enables you to make an environmentally responsible decision. Puron
refrigerant (R-410A) is an HFC refrigerant that does not contain chlorine
that is damaging to the stratospheric
ozone layer. Puron refrigerant
(R-410A) is unaffected by the Montreal
Protocol. Puron refrigerant (R-410A) is
a safe, efficient and environmentally
sound refrigerant for the future.

Quality and reliability


Excellent full and part load efficiencies
are achieved by using multiple scroll
compressors and indoor coils with intertwined dual refrigerant circuits. The
compressors are equipped with crankcase heaters and protected by electronic sensors and logic to control minimum on and off times and reverse rotation. The refrigerant circuits are both
electrically and mechanically independent, to provide standby capability
should one circuit require service.

Unique design

Novation heat exchanger


technology

A unique feature of these units with


ComfortLink controls is that the controls will support both CV, SAV, and
VAV unit operations. The controls are

The Novation heat exchanger design


with microchannel condenser coil is a
robust, cost effective alternative to
traditional coil design for standard

Table of contents

*Sponsored by ASHRAE (American Society of


Heating, Refrigerating, and Air Conditioning
Engineers).
Registered trademark of Schneider Electric.
**Registered trademark of Echelon
corporation.

Page
Features/Benefits. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5
Model Number Nomenclature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Ratings and Capacities . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-12
Physical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13-28
Options and Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29-32
Base Unit Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33-38
Accessory Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39-43
Selection Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
Performance Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45-126
Electrical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 127,128
Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 129-137
Application Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 138,139
Typical Piping and Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 140
Typical Wiring Schematics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 141-147
Guide Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 148-165

applications. Microchannel coils are


also sturdier than other coil types,
making them easier to clean without
causing damage to the coil.
Due to the compact all aluminum design, microchannel coils reduce overall
unit operating weight. The streamlined
microchannel coil also reduces refrigerant charge by up to 40%.
Microchannel coils are not recommended by Carrier for marine, coastal,
or industrial environments unless a
Carrier-approved coating is applied.

Digital scroll compressor


In air conditioning applications, the
load may vary significantly, requiring a
means to vary the system capacity for
optimal system performance and control. The P Series large rooftop units
with digital scroll compression provide
a highly efficient means of capacity
control using scroll compressors. The
digital compressor technology provides
smooth, vibration free operation by axially unloading the compliant scrolls.
By varying the amount of time that the
scrolls are unloaded, the P Series unit
is able to precisely match the system
capacity to the space load. This feature
can reduce energy consumption, provide better dehumidification, reduce
compressor cycling, and improve comfort in the space.

Humidi-MiZer adaptive dehumidification system


Carriers Humidi-MiZer adaptive dehumidification system is an all-inclusive

factory-installed option that can be ordered with any Weathermaster


48/50P2,P3,P4,P5 rooftop unit.
This system expands the envelope of
operation of the P Series rooftop to
provide unprecedented flexibility that
will meet year-round comfort
conditions.
The Humidi-MiZer adaptive dehumidification system has the industrys only
dual dehumidification mode setting.
The Weathermaster rooftop, coupled
with the Humidi-MiZer adaptive dehumidification system, is capable of operating in normal design cooling mode,
subcooling mode, and hot gas reheat
mode.
Normal design cooling mode will operate under the normal sequence of
operation. Subcooling mode will operate to satisfy part load type conditions.
Hot Gas Reheat mode will operate
when outdoor temperatures diminish
and the need for latent capacity is required for sole humidity control. Hot
Gas Reheat mode will provide neutral
air for maximum dehumidification
operation.
The Weathermaster P Series next
generation version of Carriers HumidiMiZer system includes refrigerant modulating valves that provide variable flow
bypass around the condenser. This innovative feature ensures exact control
of the supply-air temperature as the
unit lowers the evaporator temperature
to increase latent capacity.

Additionally, when the space requires dehumidification only, the Humidi-Mizer system can increase hot discharge gas bypass to the Humidi-MiZer
coil in order to heat the air to the exact
neutral state required no overcooling
or overheating with similar latent capacity as that provided in the full subcooling mode.

Staged/modulating gas control


Staged and modulating gas control options provides a supply air tempering
heat function during conditions of low
mixed air temperature while the system is still in Ventilation mode.
These low mixed air conditions occur
when the outdoor temperature is low
and the outside-air damper is in its
minimum position, so that the mixing
of cold outside air and return air results
in mixed-air temperatures below 50 F.
Both staged and modulating gas control options will raise the air temperature leaving the unit up to the tempering mode set point. Modulating gas
control option offers an enhanced control of leaving air temperature set point
by continuously modulating the heat
load. The modulating gas control reduces the burners on/off cycles in tempering mode.
The staged gas control option also
provides additional control stages of
heating operation during the normal
space demand heating function. The
modulating gas control option provides
continuous heating modulation to satisfy the space demand for heat.

TUBES

FINS

MANIFOLD
MICROCHANNELS

SPRING ISOLATION

HINGED ACCESS DOORS

NOVATION HEAT EXCHANGER


TECHNOLOGY WITH
MICROCHANNEL COILS

Features/Benefits (cont)
Design flexibility
The P Series rooftop units with
ComfortLink controls are designed to
meet all customer requirements for new
construction, replacement jobs, or special applications.
The customer can choose from the
following:
CV, SAV or VAV applications
digital scoll compressors
4 or more supply-fan motor sizes
2 sizes of natural gas heat (48 Series
units)
electric heat (50 Series units)
hydronic heat (50 Series units)
Novation microchannel (MCHX)
condenser coils or e-coated MCHX
condenser coils
integrated economizer with low-leak
dampers, barometric relief, or
power exhaust
ultra low leak economizer
return fan, economizer, and high
capacity power exhaust can be
added to size 075-100 units.
extended chassis units are provided
with space and mounting tracks for
a factory or field-installed heating
coil.
standard 2-in. filter tracks are provided but can be field-modified to
accept 4-in. panel filters
Humidi-Mizer adaptive humidification system
Discharge options The units can
be used for vertical discharge, discharge plenum vertical discharge, or
special horizontal applications, such as
replacement or sound-sensitive applications. The horizontal installation allows sound to be attenuated before the
duct penetrates the roof.
Exhaust and return options For
applications requiring higher space exhaust requirements on size 075-100
units, select vertical return and supply
or horizontal return and supply models
with optional high-capacity modulating
power exhaust and integrated economizer features.
For applications requiring high return duct static pressures on sizes 075100, select units with optional return
fan and building pressure control exhaust system. The return fan provides
a separate fan system dedicated to
overcoming flow losses in the return
duct, thus reducing the total selection
load on the units supply fan. The return fan option includes a variable frequency drive (VFD) which modulates

return fan airflow to match supply fan


airflow and to provide high exhaust
flow rate (vertical return only).
Superior space pressure control is
provided by specifying one of the modulating power exhaust systems. Modulating power exhaust systems control
exhaust fan airflow rates to maintain a
user-established space pressure set
point.

The ComfortID solution


The 48/50P ComfortLink controls
fully support the ComfortID system.
The ComfortID system is a completely
integrated control system that uses
state-of-the-art Direct Digital Controls
(DDC) to continually monitor and communicate the varying heating and cooling conditions in each zone of the
building.
The ComfortID system capabilities go
well beyond temperature control. By
adding humidity, CO2, or other IAQ
sensors, indoor air quality and consistent
comfort conditions can be tailor-made
for each zone. Proper ventilation based
on the number of occupants can be precisely maintained. Using ComfortID system for demand controlled ventilation
(DCV) allows for compliance with
ASHRAE (American Society of Heating,
Refrigerating and Air Conditioning Engineers) standard 62 and helps keep energy costs down. The ComfortID system
does not merely monitor air quality it
maintains air quality, adjusting to promote building health.

Indoor air quality (IAQ)


All units incorporate a sloped, stainless
steel condensate drain pan to prevent
standing water from accumulating inside the rooftop air-conditioning unit.
The condensate pan has a recessed
nonferrous condensate drain
connection.
Interior cabinet surfaces (except in
the supply fan discharge section) are
insulated with a flexible fire-retardant
dual-density fiberglass blanket, coated
on the air side. The coating contains
an EPA (Environmental Protection
Agency) registered immobilized antimicrobial agent to effectively resist the
growth of bacteria and fungi.
Double wall construction in the airstream is available as an option. Double wall construction with AgION
anti-microbial coating can also be
provided.
These units and controls have been
developed to provide the design
community with the flexibility to meet

individual job needs for both comfort


and IAQ. The basic unit features
include:
integrated economizer operation to
minimize mechanical cooling
requirements during intermediate
seasons
optional economizers capable of
handling up to 100% outdoor air
intertwined refrigeration circuits for
optimum performance at part load
operation
optional digital compressor provides
improved part load control
dual circuits with scroll compressors
on each circuit for reliability and
efficiency
CV and SAV units provide multistage cooling capacity control based
on thermostat or space sensor input
VAV units provide multiple stage
cooling capacity control for
improved part load operation and
efficiency
optional digital compressors come
with an infinite number of steps of
staging for unmatched load matching and part load performance
refrigeration system designed to
operate down to 32 F outdoor-air
temperature
options for a minimum of 4 sizes
of supply fan motors that meet or
exceed motor efficiency requirements of the Energy Independence
Security Act (EISA) of 2007.
modulating power exhaust fan
control
Humidi-MiZer adaptive dehumidification system

Fan modulation
Supply fan duct pressure control on
VAV models is accomplished via a variable frequency (inverter) drive (VFD).
The VFD controls supply fan airflow to
maintain a user-established duct pressure set point in the units supply duct.

Installation and serviceability


Access panels All full-size access
panels are hinged for easy access to
serviceable components. No fasteners
need to be removed from any units,
which reduces servicing time and prevents roof leaks caused by discarded
screws puncturing the roof.
Electrical connections Single
point electrical connections are standard on all units. Electrical service access can be made through roof curb or
side of unit. All 48P units provide a
single point gas connection.

Run testing To ensure a successful


start-up, every rooftop unit is factory
run tested.
Unit design Unit design is ETL
and ETL, Canada, listed according to
UL (Underwriters Laboratories) Standard 1995.
Scrolling marquee When using
the standard scrolling marquee, serviceability becomes even easier,
including:
local or remote alarm and alert
monitoring
self-diagnostic run testing to confirm
control and component operation
expedited troubleshooting and unit
repair through self-diagnostic display of unit troubleshooting alert
and alarm codes with expanded text
descriptions to immediately identify
reason for unit outage
filter maintenance alarm
monitoring of supply-air fan run
time, permitting easy service schedule planning
Tranducers Serviceability is further
facilitated with suction and discharge
pressure transducers. These allow suction pressure and discharge pressure to
be monitored remotely with alarm capability. These transducers also control
condenser head pressure to maintain
the minimum differential pressure required across the thermostatic expansion valve (TXV) for proper operation,
which reduces energy consumption.
Non-fused disconnect A factoryinstalled non-fused disconnect (NFD)
option is available to simplify unit installation and improve unit serviceability. The location of the NFD in the
main control box simplifies field power
supply routing into the unit. The NFD
incorporates an access panel interlock
feature, ensuring that all power to the
unit will be disconnected before a service person opens the control box.

Gas heat units (48P units)


The 48P units are gas heating units,
using natural gas combustion, with two
heat sizes available for every unit.
The unit heating systems employ
multiple heat exchanger sections, with

each section equipped with a 2-stage


redundant gas valve and independent
ignition control, with all sections operating in parallel.
Units with gas modulating heating
are equipped with an additional modulating gas valve installed downstream
of the 2-stage redundant gas valve.
Heat exchanger The tubular steel
heat exchanger design optimizes heat
transfer for improved efficiency. The
tubular design permits multiple passes
across the supply air path. Each tube
has an individual inshot burner, ensuring uniform combustion in each tube
of the heat exchangers. Tubes are dimpled to create a turbulent gas flow to
maximize heat efficiency and to ensure
uniform surface temperatures for reduced corrosion effects, improved durability and long-life service. Heat exchanger material is aluminized steel or
stainless steel, for improved corrosion
resistance and reliability.
Integrated gas unit controller
The IGC (integrated gas unit controller)
ignition and safety control system is
used on each heat exchanger section.
The IGC, unique to Carrier rooftop
units, simplifies system evaluation and
troubleshooting by providing system
status and visual fault notification via
an on-board LED (light-emitting diode).
Ignition is initiated by a direct spark
ignition system; flame status is determined by flame rectification process.
Combustion fan operation is proven
by a Hall Effect speed sensor circuit for
units equipped with 2-stage or staged
gas heat. For units equipped with modulating gas heat, combustion fan operation is proven with a pressure switch.
Safeties include flame rollout and limit
switch. Auto reset with manual lockout
is also provided for repeated limit
switch trips. The IGC also prevents
short-cycling due to thermostat jiggle
by ensuring a full minute heating cycle
operation on each call for heat.
Gas heat system The induced
draft fan system draws hot combustion
gas through the heat exchanger tubes
at the optimum rate for the most effective heat transfer and combustion

process. The heat exchanger operates under a negative pressure, preventing flue gas leakage into the indoor
supply air.
Flue outlet hoods with wind baffles
are located on the side of the unit, to
minimize the effects of wind on heating operations.
Standard units use 2-stage control,
for unoccupied, morning warm-up and
occupied space heating.
Additional control stages for heating
operation are available by specifying
the staged gas control option.
Modulating control option is available by specifying the modulating gas
control option.
A single hinged panel gains access
to the complete heat exchanger
assembly and controls, for improved
serviceability.
A single point gas connection provides for easy installation.
An LP (liquid propane) conversion
accessory can be field-installed on gas
units without staged or modulating gas
control option (sizes 030-070 for vertical low heat units and sizes 030-050
for vertical high heat units).
Optional modulating gas heat
The modulating gas heat option monitors unit supply-air temperature and
controls the unit heat exchanger to
provide first-stage demand heating
control, with modulation to maintain
user-configured heating supply air temperature set point.
The option also provides full-fire demand heating on heating control command and tempering heat control,
based on user-configured ventilation
supply air temperature set point, to
eliminate cold draft conditions with low
mixed-air temperatures.
The modulating gas control option
consists of a modulating controller capable of ensuring the proper fuel air
mixture at operating firing rates, supply air temperature thermistors with
duct-mounting base, a limit switch temperature thermistor, and stainless steel
heat exchanger tubes.

Model number nomenclature


48P2,P3,P4,P5 UNITS

a48-8637

48 P2 D

030

Option Code
Factory Options
See note below

48 Cooling Unit with Gas Heat


Configuration
P2 Vertical Suppy/Return, CV/SAV ComfortLink Controls
P3 Vertical Supply/Return, VAV ComfortLink Controls
P4 Horizontal Suppy/Return, CV/SAV ComfortLink Controls
P5 Horizontal Suppy/Return, VAV ComfortLink Controls

Heat and Chassis Options


Low Gas Heat, Humidi-MiZer System
A High Gas Heat, Humidi-MiZer System
B Low Gas Heat, Stainless Steel
C High Gas Heat, Stainless Steel
D Low Gas Heat
E High Gas Heat
F Low Staged Gas Heat, Stainless Steel, Humidi-MiZer System
G High Staged Gas Heat, Stainless Steel, Humidi-MiZer System
H Low Staged Gas Heat, Stainless Steel
J High Staged Gas Heat, Stainless Steel
K Low Modulating Gas Heat, Stainless Steel
L High Modulating Gas Heat, Stainless Steel
M Low Gas Heat, Stainless Steel, Humidi-MiZer System
N High Gas Heat, Stainless Steel, Humidi-MiZer System
P Low Gas Heat, Stainless Steel, Extended Chassis
Q High Gas Heat, Stainless Steel, Extended Chassis
R Low Gas Heat with Extended Chassis
S High Gas Heat with Extended Chassis
W Low Staged Gas Heat, Stainless Steel, with Extended Chassis
X High Staged Gas Heat, Stainless Steel, with Extended Chassis
Y Low Modulating Gas Heat, Stainless Steel, Humidi-MiZer System
Z High Modulating Gas Heat, Stainless Steel, Humidi-MiZer System
2 Low Modulating Gas Heat, Stainless Steel, with Extended Chassis
3 High Modulating Gas Heat, Stainless Steel, with Extended Chassis

Design Revision Level


0 Initial Release
1 First Revision

Voltage Options
1 575-3-60
5 208/230-3-60
6 460-3-60

Unit Size Nominal Tons


030 30
060 60
035 35
070 70
040 40
075 75
050 50
090 90
055 55
100 100

LEGEND
CV
Constant Volume
SAV Staged Air Volume
VAV
Variable Air Volume
NOTE: Because of the large number of options and the many resulting combinations, the Applied Rooftop Builder software must be
used to generate the 8-digit option code for the unit model number.
Refer to the software for the different choices for unit factoryinstalled options. Once all of the options have been selected, the
software will generate the correct code. Unit options and accessories are listed in the Options and Accessories section on page 29.

50P2,P3,P4,P5 UNITS

a50-8722

50 P2 D 030

6 1 Option Code
Factory Options
See note below

50 Cooling Unit with Electric heat


Configuration
P2 Vertical Suppy/Return, CV/SAV ComfortLink Controls
P3 Vertical Supply/Return, VAV ComfortLink Controls
P4 Horizontal Suppy/Return, CV/SAV ComfortLink Controls
P5 Horizontal Suppy/Return, VAV ComfortLink Controls
Heat and Chassis Options
- No Heat
A Low Electric Heat
B Medium Electric Heat
C High Electric Heat
D No Heat, Humidi-MiZer System
E Low Electric Heat, Humidi-MiZer System
F Medium Electric Heat, Humidi-MiZer System
G High Electric Heat, Humidi-MiZer System
H No Heat with Discharge Plenum
J No Heat with Discharge Plenum, Humidi-MiZer System
P No Heat with Discharge Plenum and Extended Chassis
R No Heat with Extended Chassis
S Low Electric Heat with Extended Chassis
T Medium Electric Heat with Extended Chassis
V High Electric Heat with Extended Chassis
W No Electric Heat with Extended Chassis and Hot Water Coil
Y No Electric Heat with Discharge Plenum, Extended Chassis
and Hot Water Coil
Z Low Electric Heat, Humidi-MiZer with SCR Control
2 Medium Electric Heat, Humidi-MiZer with SCR Control
3 High Electric Heat, Humidi-MiZer with SCR Control
4 Low Electric Heat, with Extended Chassis with SCR Control
5 Medium Electric Heat, with Extended Chassis with SCR Control
6 High Electric Heat, with Extended Chassis with SCR Control

Quality Assurance
Certified to ISO 9001
6

Design Revision Level


0 Initial Release
1 First Revision
Voltage Options
1 575-3-60
2 380-3-60
5 208/230-3-60
6 460-3-60
Unit Size Nominal Tons
030 30
060 60
035 35
070 70
040 40
075 75
050 50
090 90
055 55
100 100

CV
SAV
SCR
VAV

LEGEND
Constant Volume
Staged Air Volume
Electronic Fan Speed Controller
Variable Air Volume

NOTE: Because of the large number of options and the many resulting combinations, the Applied Rooftop Builder software must be
used to generate the 8-digit option code for the unit model number.
Refer to the software for the different choices for unit factoryinstalled options. Once all of the options have been selected, the
software will generate the correct code. Unit options and accessories are listed in the Options and Accessories section on page 29.

Ratings and capacities


UNIT DESIGN AIRFLOW LIMITS
UNIT SIZE

UNIT TYPE
48P2,P3,P4,P5 Low Heat
48P2,P3,P4,P5 High Heat
50P2,P3,P4,P5
48P2,P3,P4,P5 Low Heat
48P2,P3,P4,P5 High Heat
50P2,P3,P4,P5
48P2,P3,P4,P5 Low Heat
48P2,P3,P4,P5 High Heat
50P2,P3,P4,P5
48P2,P3,P4,P5 Low Heat
48P2,P3,P4,P5 High Heat
50P2,P3,P4,P5
48P2,P3,P4,P5 Low Heat
48P2,P3,P4,P5 High Heat
50P2,P3,P4,P5
48P2,P3,P4,P5 Low Heat
48P2,P3,P4,P5 High Heat
50P2,P3,P4,P5
48P2,P3,P4,P5 Low Heat
48P2,P3,P4,P5 High Heat
50P2,P3,P4,P5
48P2,P3,P4,P5 Low Heat
48P2,P3,P4,P5 High Heat
50P2,P3,P4,P5
48P2,P3,P4,P5 Low Heat
48P2,P3,P4,P5 High Heat
50P2,P3,P4,P5
48P2,P3,P4,P5 Low Heat
48P2,P3,P4,P5 High Heat
50P2,P3,P4,P5

030

035

040

050

055

060

070

075

090

100

MINIMUM COOLING CFM


6,000
6,000
6,000
7,000
7,000
7,000
8,000
8,000
8,000
9,000
9,000
9,000
10,000
10,000
10,000
12,000
12,000
12,000
14,000
14,000
14,000
15,000
15,000
15,000
17,000
17,000
17,000
20,000
20,000
20,000

MAXIMUM CFM
15,000
15,000
15,000
15,000
15,000
15,000
20,000
20,000
20,000
20,000
19,500
20,000
25,000
25,000
25,000
30,000
30,000
30,000
30,000
30,000
30,000
30,000
30,000
30,000
40,000
37,000
40,000
44,000
37,000
44,000

NOTE: Refer to Application Data section for more information concerning minimum operating airflow in Cooling mode.

TWO-STAGE GAS HEATING CAPACITIES 48P2,P3 UNITS


(Natural Gas on All Units and LP Gas on 030-070 Low Heat and 030-050 High Heat Units)
UNIT
48P2,P3
030-050 Low Heat
030-050 High Heat
055-070 Low Heat
055-070 High Heat
075-100 Low Heat
075-100 High Heat

GAS INPUT (1000 Btuh)


Stage 1
Stage 2
244
325
488
650
488
650
731
975
488
650
731
975

EFFICIENCY
(%)
81.0%
81.0%
80.7%
80.7%
80.9%
80.4%

LEGEND
LP Liquid Propane
NOTES:
1. Ratings are approved for altitudes to 2000 ft. At altitudes over
2000 ft, ratings are 4% less for each 1000 ft above sea level.
2. At altitudes up to 2000 ft, the following formula may be used to calculate air temperature rise:
t =

OUTPUT CAPACITY (1000 Btuh)


Stage 1
Stage 2
197
263
395
527
393
525
590
787
394
526
588
784

TEMP RISE
(F)
10-40
25-55
10-40
20-50
10-40
20-50

AIRFLOW (Cfm)
Min
Max
6,094
20,000
8,864
19,259
12,142
30,000
14,571
30,000
12,172
44,000
14,517
36,292

4. Minimum allowable temperature of mixed air entering the heat


exchanger during half-rate (first stage) operation is 35 F. There is no
minimum mixture temperature limitation during full-rate operation.
5. Temperature rise limits: see table.
6. On VAV (variable air volume) applications set the zone terminals to
provide minimum unit heating airflow as indicated in the table upon
command from Heat Interlock Relay (HIR) function.

maximum output capacity


1.10 x air quantity

3. At altitudes above 2000 ft, the following formula may be used:


t =

maximum output capacity


(.24 x specific weight of air x 60) (air quantity)

Ratings and capacities (cont)


TWO-STAGE GAS HEATING CAPACITIES 48P4,P5 UNITS
(Natural Gas on All Units and LP Gas Not Available)
UNIT
48P4,P5
030-050 Low Heat
030-050 High Heat
055-070 Low Heat
055-070 High Heat
075-100 Low Heat
075-100 High Heat

GAS INPUT (1000 Btuh)


Stage 1
Stage 2
244
325
488
650
488
650
731
975
488
650
731
975

EFFICIENCY
(%)
80.0%
80.0%
80.0%
80.0%
80.0%
80.0%

LEGEND

TEMP RISE
(F)
10-40
25-55
10-40
20-50
10-40
20-50

AIRFLOW (Cfm)
Min
Max
6,019
20,000
8,754
19,259
12,037
30,000
14,444
30,000
12,037
44,000
14,444
36,111

3. At altitudes above 2000 ft, the following formula may be used:

LP Liquid Propane
NOTES:
1. Ratings are approved for altitudes to 2000 ft. At altitudes over
2000 ft, ratings are 4% less for each 1000 ft above sea level.
2. At altitudes up to 2000 ft, the following formula may be used to calculate air temperature rise:
maximum output capacity
1.10 x air quantity

t =

OUTPUT CAPACITY (1000 Btuh)


Stage 1
Stage 2
195
260
390
520
390
520
585
780
390
520
585
780

t =

maximum output capacity


(.24 x specific weight of air x 60) (air quantity)

4. Minimum allowable temperature of mixed air entering the heat


exchanger during half-rate (first stage) operation is 35 F. There is no
minimum mixture temperature limitation during full-rate operation.
5. Temperature rise limits: see table.
6. On VAV (variable air volume) applications set the zone terminals to
provide minimum unit heating airflow as indicated in the table upon
command from Heat Interlock Relay (HIR) function.

GAS HEATING CAPACITIES UNITS WITH STAGED GAS CONTROL OPTION


48P2,P3 030-050 LOW HEAT
HEATING
STAGES
1
2

INPUT
CAPACITY
(1000 Btuh)
244
325

% FULL FIRE

THERMAL
EFFICIENCY %

75%
100%

81.0%
81.0%

OUTPUT
CAPACITY
(1000 Btuh)
197.4
263.3

OUTPUT CAPACITY PER SECTION (1000 Btuh)


SECTION 1

SECTION 2

SECTION 3

197.4
263.3

N/A
N/A

N/A
N/A

48P4,P5 030-050 LOW HEAT


HEATING
STAGES
1
2

INPUT
CAPACITY
(1000 Btuh)
244
325

% FULL FIRE

THERMAL
EFFICIENCY %

75%
100%

80.0%
80.0%

OUTPUT
CAPACITY
(1000 Btuh)
195.0
260.0

OUTPUT CAPACITY PER SECTION (1000 Btuh)


SECTION 1

SECTION 2

SECTION 3

195.0
260.0

N/A
N/A

N/A
N/A

48P2,P3 030-050 HIGH HEAT


HEATING
STAGES
1
2
3
4
5

INPUT
CAPACITY
(1000 Btuh)
244
325
488
569
650

% FULL FIRE

THERMAL
EFFICIENCY %

38%
50%
75%
88%
100%

81.0%
81.0%
81.0%
81.0%
81.0%

OUTPUT
CAPACITY
(1000 Btuh)
197.4
263.3
394.9
460.7
526.5

OUTPUT CAPACITY PER SECTION (1000 Btuh)


SECTION 1

SECTION 2

SECTION 3

197.4
263.3
197.4
263.3
263.3

0.0
0.0
197.4
197.4
263.3

N/A
N/A
N/A
N/A
N/A

48P4,P5 030-050 HIGH HEAT


HEATING
STAGES
1
2
3
4
5

INPUT
CAPACITY
(1000 Btuh)
244
325
488
569
650

% FULL FIRE

THERMAL
EFFICIENCY %

38%
50%
75%
88%
100%

80.0%
80.0%
80.0%
80.0%
80.0%

OUTPUT
CAPACITY
(1000 Btuh)
195.0
260.0
390.0
455.0
520.0

OUTPUT CAPACITY PER SECTION (1000 Btuh)


SECTION 1

SECTION 2

SECTION 3

195.0
260.0
195.0
260.0
260.0

0.0
0.0
195.0
195.0
260.0

N/A
N/A
N/A
N/A
N/A

GAS HEATING CAPACITIES UNITS WITH STAGED GAS CONTROL OPTION (cont)
48P2,P3 055-070 LOW HEAT
HEATING
STAGES
1
2
3
4
5

INPUT
CAPACITY
(1000 Btuh)
244
325
488
569
650

% FULL FIRE

THERMAL
EFFICIENCY %

38%
50%
75%
88%
100%

80.7%
80.7%
80.7%
80.7%
80.7%

OUTPUT
CAPACITY
(1000 Btuh)
196.7
262.3
393.4
459.0
524.6

OUTPUT CAPACITY PER SECTION (1000 Btuh)


SECTION 1

SECTION 2

SECTION 3

196.7
262.3
196.7
262.3
262.3

0.0
0.0
196.7
196.7
262.3

N/A
N/A
N/A
N/A
N/A

48P4,P5 055-070 LOW HEAT


HEATING
STAGES
1
2
3
4
5

INPUT
CAPACITY
(1000 Btuh)
244
325
488
569
650

% FULL FIRE

THERMAL
EFFICIENCY %

38%
50%
75%
88%
100%

80.0%
80.0%
80.0%
80.0%
80.0%

OUTPUT
CAPACITY
(1000 Btuh)
195.0
260.0
390.0
455.0
520.0

OUTPUT CAPACITY PER SECTION (1000 Btuh)


SECTION 1

SECTION 2

SECTION 3

195.0
260.0
195.0
260.0
260.0

0.0
0.0
195.0
195.0
260.0

N/A
N/A
N/A
N/A
N/A

48P2,P3 055-070 HIGH HEAT


HEATING
STAGES
1
2
3
4
5
6
7
8
9

INPUT
CAPACITY
(1000 Btuh)
244
325
488
569
650
731
813
894
975

% FULL FIRE

THERMAL
EFFICIENCY %

25%
33%
50%
58%
67%
75%
83%
92%
100%

80.7%
80.7%
80.7%
80.7%
80.7%
80.7%
80.7%
80.7%
80.7%

OUTPUT
CAPACITY
(1000 Btuh)
196.7
262.3
393.4
459.0
524.6
590.1
655.7
721.3
786.8

OUTPUT CAPACITY PER SECTION (1000 Btuh)


SECTION 1

SECTION 2

SECTION 3

196.7
262.3
196.7
262.3
262.3
196.7
196.7
262.3
262.3

0.0
0.0
196.7
196.7
262.3
196.7
262.3
262.3
262.3

0.0
0.0
0.0
0.0
0.0
196.7
196.7
196.7
262.3

48P4,P5 055-070 HIGH HEAT


HEATING
STAGES
1
2
3
4
5
6
7
8
9

INPUT
CAPACITY
(1000 Btuh)
244
325
488
569
650
731
813
894
975

% FULL FIRE

THERMAL
EFFICIENCY %

25%
33%
50%
58%
67%
75%
83%
92%
100%

80.0%
80.0%
80.0%
80.0%
80.0%
80.0%
80.0%
80.0%
80.0%

OUTPUT
CAPACITY
(1000 Btuh)
195.0
260.0
390.0
455.0
520.0
585.0
650.0
715.0
780.0

OUTPUT CAPACITY PER SECTION (1000 Btuh)


SECTION 1

SECTION 2

SECTION 3

195.0
260.0
195.0
260.0
260.0
195.0
195.0
260.0
260.0

0.0
0.0
195.0
195.0
260.0
195.0
260.0
260.0
260.0

0.0
0.0
0.0
0.0
0.0
195.0
195.0
195.0
260.0

48P2,P3 075-100 LOW HEAT


HEATING
STAGES
1
2
3
4
5

INPUT
CAPACITY
(1000 Btuh)
244
325
488
569
650

% FULL FIRE

THERMAL
EFFICIENCY %

38%
50%
75%
88%
100%

80.9%
80.9%
80.9%
80.9%
80.9%

OUTPUT
CAPACITY
(1000 Btuh)
197.2
262.9
394.4
460.1
525.9

OUTPUT CAPACITY PER SECTION (1000 Btuh)


SECTION 1

SECTION 2

SECTION 3

197.2
262.9
197.2
262.9
262.9

0.0
0.0
197.2
197.2
262.9

N/A
N/A
N/A
N/A
N/A

Ratings and capacities (cont)


GAS HEATING CAPACITIES UNITS WITH STAGED GAS CONTROL OPTION (cont)
48P4,P5 075-100 LOW HEAT
HEATING
STAGES
1
2
3
4
5

INPUT
CAPACITY
(1000 Btuh)
244
325
488
569
650

% FULL FIRE

THERMAL
EFFICIENCY %

38%
50%
75%
88%
100%

80.0%
80.0%
80.0%
80.0%
80.0%

OUTPUT
CAPACITY
(1000 Btuh)
195.0
260.0
390.0
455.0
520.0

OUTPUT CAPACITY PER SECTION (1000 Btuh)


SECTION 1

SECTION 2

SECTION 3

195.0
260.0
195.0
260.0
260.0

0.0
0.0
195.0
195.0
260.0

N/A
N/A
N/A
N/A
N/A

48P2,P3 075-100 HIGH HEAT


HEATING
STAGES
1
2
3
4
5
6
7
8
9

INPUT
CAPACITY
(1000 Btuh)
244
325
488
569
650
731
813
894
975

% FULL FIRE

THERMAL
EFFICIENCY %

25%
33%
50%
58%
67%
75%
83%
92%
100%

80.4%
80.4%
80.4%
80.4%
80.4%
80.4%
80.4%
80.4%
80.4%

OUTPUT
CAPACITY
(1000 Btuh)
196.0
261.3
392.0
457.3
522.6
587.9
653.3
718.6
783.9

OUTPUT CAPACITY PER SECTION (1000 Btuh)


SECTION 1

SECTION 2

SECTION 3

196.0
261.3
196.0
261.3
261.3
196.0
196.0
261.3
261.3

0.0
0.0
196.0
196.0
261.3
196.0
261.3
261.3
261.3

0.0
0.0
0.0
0.0
0.0
196.0
196.0
196.0
261.3

48P4,P5 075-100 HIGH HEAT


HEATING
STAGES
1
2
3
4
5
6
7
8
9

INPUT
CAPACITY
(1000 Btuh)
244
325
488
569
650
731
813
894
975

% FULL FIRE

THERMAL
EFFICIENCY %

25%
33%
50%
58%
67%
75%
83%
92%
100%

80.0%
80.0%
80.0%
80.0%
80.0%
80.0%
80.0%
80.0%
80.0%

OUTPUT
CAPACITY
(1000 Btuh)
195.0
260.0
390.0
455.0
520.0
585.0
650.0
715.0
780.0

OUTPUT CAPACITY PER SECTION (1000 Btuh)


SECTION 1

SECTION 2

SECTION 3

195.0
260.0
195.0
260.0
260.0
195.0
195.0
260.0
260.0

0.0
0.0
195.0
195.0
260.0
195.0
260.0
260.0
260.0

0.0
0.0
0.0
0.0
0.0
195.0
195.0
195.0
260.0

GAS HEATING CAPACITIES UNITS WITH MODULATING GAS CONTROL OPTION


48P2,P3 030-050 LOW HEAT
GAS INPUT
(1000 Btuh)

PERCENT
FULL FIRE

92 - 325

28 - 100%

OUTPUT
CAPACITY
(1000 Btuh)
68 - 263

FIRING STAGE
1

Modulating

48P4,P5 030-050 LOW HEAT


GAS INPUT
(1000 Btuh)

PERCENT
FULL FIRE

92 - 325

28 - 100%

OUTPUT
CAPACITY
(1000 Btuh)
68 - 260

FIRING STAGE
1

Modulating

48P2,P3 030-050 HIGH HEAT


GAS INPUT
(1000 Btuh)

PERCENT
FULL FIRE

92 - 325
335 - 569
416 - 650

14 - 50%
52 - 88%
64 - 100%

LEGEND
HF High Fire
LF Low Fire

10

OUTPUT
CAPACITY
(1000 Btuh)
68 - 256
265 - 455
333 - 527

FIRING STAGE
1

Modulating
Modulating
Modulating

0
LF
HF

GAS HEATING CAPACITIES UNITS WITH MODULATING GAS CONTROL OPTION (cont)
48P4,P5 030-050 HIGH HEAT
GAS INPUT
(1000 Btuh)

PERCENT
FULL FIRE

92 - 325
335 - 569
416 - 650

14 - 50%
52 - 88%
64 - 100%

OUTPUT
CAPACITY
(1000 Btuh)
68 - 256
265 - 455
333 - 520

FIRING STAGE
1

Modulating
Modulating
Modulating

0
LF
HF

48P2,P3 055-070 LOW HEAT


GAS INPUT
(1000 Btuh)

PERCENT
FULL FIRE

92 - 325
335 - 569
416 - 650

14 - 50%
52 - 88%
64 - 100%

OUTPUT
CAPACITY
(1000 Btuh)
68 - 256
265 - 455
333 - 525

FIRING STAGE
1

Modulating
Modulating
Modulating

0
LF
HF

48P4,P5 055-070 LOW HEAT


GAS INPUT
(1000 Btuh)

PERCENT
FULL FIRE

92 - 325
335 - 569
416 - 650

14 - 50%
52 - 88%
64 - 100%

OUTPUT
CAPACITY
(1000 Btuh)
68 - 256
265 - 455
333 - 520

FIRING STAGE
1

Modulating
Modulating
Modulating

0
LF
HF

48P2,P3 055-070 HIGH HEAT


GAS INPUT
(1000 Btuh)

PERCENT
FULL FIRE

92 - 325
335 - 569
416 - 650
579 - 813
660 - 894
741 - 975

9 - 33%
34 - 58%
43 - 67%
59 - 83%
68 - 92%
76 - 100%

OUTPUT
CAPACITY
(1000 Btuh)
68 - 256
265 - 455
333 - 520
463 - 650
528 - 721
593 - 787

FIRING STAGE
1

Modulating
Modulating
Modulating
Modulating
Modulating
Modulating

0
LF
HF
LF
HF
HF

0
0
0
LF
LF
HF

48P4,P5 055-070 HIGH HEAT


GAS INPUT
(1000 Btuh)

PERCENT
FULL FIRE

92 - 325
335 - 569
416 - 650
579 - 813
660 - 894
741 - 975

9 - 33%
34 - 58%
43 - 67%
59 - 83%
68 - 92%
76 - 100%

OUTPUT
CAPACITY
(1000 Btuh)
68 - 256
265 - 455
333 - 520
463 - 650
528 - 721
593 - 780

FIRING STAGE
1

Modulating
Modulating
Modulating
Modulating
Modulating
Modulating

0
LF
HF
LF
HF
HF

0
0
0
LF
LF
HF

48P2,P3 075-100 LOW HEAT


GAS INPUT
(1000 Btuh)

PERCENT
FULL FIRE

92 - 325
335 - 569
416 - 650

14 - 50%
52 - 88%
64 - 100%

OUTPUT
CAPACITY
(1000 Btuh)
68 - 256
265 - 455
333 - 526

FIRING STAGE
1

Modulating
Modulating
Modulating

0
LF
HF

48P4,P5 075-100 LOW HEAT


GAS INPUT
(1000 Btuh)

PERCENT
FULL FIRE

92 - 325
335 - 569
416 - 650

14 - 50%
52 - 88%
64 - 100%

OUTPUT
CAPACITY
(1000 Btuh)
68 - 256
265 - 455
333 - 520

FIRING STAGE
1

Modulating
Modulating
Modulating

0
LF
HF

LEGEND
HF High Fire
LF Low Fire

11

Ratings and capacities (cont)


GAS HEATING CAPACITIES UNITS WITH MODULATING GAS CONTROL OPTION (cont)
48P2,P3 075-100 HIGH HEAT
GAS INPUT
(1000 Btuh)

PERCENT
FULL FIRE

92 - 325
335 - 569
416 - 650
579 - 813
660 - 894
741 - 975

9 - 33%
34 - 58%
43 - 67%
59 - 83%
68 - 92%
76 - 100%

OUTPUT
CAPACITY
(1000 Btuh)
68 - 256
265 - 455
333 - 520
463 - 650
528 - 719
593 - 784

FIRING STAGE
1

Modulating
Modulating
Modulating
Modulating
Modulating
Modulating

0
LF
HF
LF
HF
HF

0
0
0
LF
LF
HF

48P4,P5 075-100 HIGH HEAT


GAS INPUT
(1000 Btuh)

PERCENT
FULL FIRE

92 - 325
335 - 569
416 - 650
579 - 813
660 - 894
741 - 975

9 - 33%
34 - 58%
43 - 67%
59 - 83%
68 - 92%
76 - 100%

OUTPUT
CAPACITY
(1000 Btuh)
68 - 256
265 - 455
333 - 520
463 - 650
528 - 715
593 - 780

FIRING STAGE
1

Modulating
Modulating
Modulating
Modulating
Modulating
Modulating

0
LF
HF
LF
HF
HF

0
0
0
LF
LF
HF

LEGEND
HF High Fire
LF Low Fire

ELECTRIC HEATER CAPACITIES


UNIT SIZE
50P2,P3030-050
208 v
230 v
380 v
460 v
575 v
50P2,P3055-070
208 v
230 v
380 v
460 v
575 v
50P2,P3,P4,P5075-100
460 v

NO. STAGES

LOW
(kW)

CAPACITY
PER
STAGE (%)

MED
(kW)

CAPACITY
PER
STAGE (%)

HIGH
(kW)

CAPACITY
PER
STAGE (%)

MIN
CFM

MAX
CFM

2
2
2
2
2

29
36
25
36
36

50,100
50,100
50,100
50,100
50,100

59
72
51
72
72

50,100
50,100
50,100
50,100
50,100

88
108
76
108
108

67,100
67,100
67,100
67,100
67,100

9,000
9,000
9,000
9,000
9,000

20,000
20,000
20,000
20,000
20,000

2
2
2
2
2

29
36
25
36
36

50,100
50,100
50,100
50,100
50,100

59
72
51
72
72

50,100
50,100
50,100
50,100
50,100

88
108
76
108
108

67,100
67,100
67,100
67,100
67,100

15,000
15,000
15,000
15,000
15,000

30,000
30,000
30,000
30,000
30,000

108

67,100

216

50,100

15,000

44,000

NOTES:
1. Electric heat options are NOT AVAILABLE on discharge plenum units or size 030-070 horizontal units.
2. Electric heat is available on horizontal size 075-100 units with airfoil fan option only.

12

Physical data 48 series units


48P2,P3,P4,P5030-050
BASE UNIT
NOMINAL CAPACITY (tons)
OPERATING WEIGHT (lb)
Base Unit
Low Heat
High Heat
With Economizer
Low Heat
High Heat
COMPRESSORS
Quantity...Type
Oil Charge (oz) per Compressor
Number of Refrigerant Circuits
REFRIGERANT
Operating Charge (lb), Ckt 1/Ckt 2
Standard Evaporator Coil
Standard Evaporator with Humidi-MiZer System
Alternate High-Capacity Evaporator Coil
Alternate High-Capacity Evaporator with Humidi-MiZer
CONDENSER COILS
Quantity
Total Face Area (sq ft)
EVAPORATOR COILS
Quantity
Total Face Area (sq ft)
Refrigerant Feed Device...No. per Circuit
Standard Evaporator Coils
Rows...Fins/in.
Fin Type
Tube Type
Alternate, High-Capacity Evaporator Coils
Rows...Fins/in.
Fin Type
Tube Type
HEATING SECTION
Number of Heat Exchangers
Input (MBtuh)
Output (MBtuh) (Vertical/Horizontal)
Temperature Rise Range (F)
Efficiency (%) (Vertical/Horizontal)
Burner Orifice Diameter
Quantity (in. ...drill no.)
Manifold Pressure (in. wg)
Line Pressure (in. wg) (min...max)
Firing Stages
Number of Gas Valves
CONDENSER FANS
Quantity...Diameter (in.)
Nominal Cfm
Motor Hp...Rpm
SUPPLY FAN
Nominal Cfm
Maximum Allowable Cfm
Maximum Allowable Rpm
Shaft Diameter at Pulley (in.)
SUPPLY-FAN MOTOR AND DRIVE
Motor Hp
Motor Frame Size
Efficiency at Full Load (%)
Fan Pulley Pitch Diameter (in.)
Motor Pulley Pitch Diameter (in.)
Resulting Fan Speed (rpm)
Belts Quantity...Type
Center Distance Range (in.)
OPTIONAL POWER EXHAUST
Quantity...Motor Hp
Motor Frame Size
Efficiency at Full Load (%)
Fan Pulley Pitch Diameter (in.)
Motor Pulley Pitch Diameter Range (in.)
Motor Pulley Pitch Diameter Factory Setup (in.)
Blower Shaft Diameter at Pulley (in.)
Fan Rpm Range
Factory Setup Fan Rpm
Maximum Allowable Rpm
FILTERS
Standard Efficiency Throwaway (Standard)
Quantity...Size (in.)
Medium Efficiency (30%) Pleated (Optional)
Quantity...Size (in.)
High Efficiency (90%) Bag Filters
with High Velocity Prefilters (Opt)
Quantity...Size (in.)
Bag Filter
Prefilter
Cartridge Filters with High Velocity Prefilters (Opt)
Quantity...Size (in.)
Cartridge Filter
Prefilter
OUTSIDE AIR SCREENS
Standard Hood (25%) Quantity...Size (in.)
OPTIONAL ECONOMIZER FILTER
Quantity...Size (in.)

48P2,P3,P4,P5030
30
Standard Chassis
Extended Chassis

48P2,P3,P4,P5035
35
Standard Chassis
Extended Chassis

5310
5440

5810
5940

5410
5540

5910
6040

5610
5740

6110
6240

5710
5840

6210
6340

Scroll
1...ZP154/1...ZP154
110
2

1...ZP182/1...ZP182
110
2
R-410A

15.4/14.8
18.4/17.6
15.4/24.9
18.4/27.7
17.2/16.0
N/A
17.2/26.1
N/A
Aluminum Novation Heat Exchanger with Microchannel Coils
1
1
33.3
33.3
1
32.1
TXV...1
3...15.0
Double Wavy
Cross Hatched

4...15.0
Double Wavy
Cross Hatched

4...15.0
Double Wavy
Cross Hatched

N/A
N/A
N/A

Low Heat
7
325
263/260
10-40
81/80

High Heat
14
650
527/520
25-55
81/80

Low Heat
7
325
263/260
10-40
81/80

High Heat
14
650
527/520
25-55
81/80

7 (.1285...30)
3.5
5.0...13.0
2
1

14 (.1285...30)
3.5
5.0...13.0
2
2

7 (.1258...30)
3.5
5.0...13.0
2
1

14 (.1258...30)
3.5
5.0...13.0
2
2

Propeller Type
2...30
18,000
1.0...1140

2...30
19,500
1.0...1140
Centrifugal 25 x 25 in.

10,500
15,000
900
111/16

10,500
15,000
900
111/16

(Any motor available on any unit)


10
15
20
215T
254T
256T
91.7
93.0
93.6
13.7
13.7
13.7
4.3
4.9
5.5
549
626
703
2...5VX630
2...5VX630
2...5VX630
17.74-14.30
17.63...14.01
17.63...14.01
Centrifugal, 18 x 15 in. (Any motor available on any unit)
2...5.0
2...7.5
184T
213T
89.5
91.7
10.4
12
4.7-3.7
6.0-4.8
4.2
5.4
17/16
17/16
621-785
717-882
703
800
1000
1000

7.5
213T
91.7
13.7
3.4
438
2...BX60
17.74-14.30
2...3.0
182T
88.5
11.0
4.1-3.1
4.1
17/16
500-656
656
1000

25
284T
93.6
13.7
6.5
830
2...5VX650
16.63...12.87
2...10
215T
91.7
12
7.0-5.8
6.4
17/16
854-1000
927
1000

8...20 x 25 x 2, 8...20 x 20 x 2

8...20 x 25 x 2, 8...20 x 20 x 2

8...20 x 25 x 2, 8...20 x 20 x 2

8...20 x 25 x 2, 8...20 x 20 x 2

6...20 x 24 x 22, 6...20 x 20 x 22


12...16 x 20 x 2, 3...20 x 24 x 2

6...20 x 24 x 22, 6...20 x 20 x 22


12...16 x 20 x 2, 3...20 x 24 x 2

6...20 x 24 x 12, 6...20 x 20 x 12


12...16 x 20 x 2, 3...20 x 24 x 2

6...20 x 24 x 12, 6...20 x 20 x 12


12...16 x 20 x 2, 3...20 x 24 x 2

None

None
Aluminum Frame, Permanent

5...20 x 20 x 2
2...20 x 25 x 1

5...20 x 20 x 1
2...20 x 25 x 1

LEGEND
MBtuh Btuh in Thousands
TXV
Thermostatic Expansion Valve
* 460-3-60 only.
See Power Exhaust Fan Drive Data table on page 28 for more information.

13

Physical data 48 series units (cont)


48P2,P3,P4,P5030-050 (cont)
BASE UNIT
NOMINAL CAPACITY (tons)
OPERATING WEIGHT (lb)
Base Unit
Low Heat
High Heat
With Economizer
Low Heat
High Heat
COMPRESSORS
Quantity...Type
Oil Charge (oz) per Compressor
Number of Refrigerant Circuits
REFRIGERANT
Operating Charge (lb), Ckt 1/Ckt 2
Standard Evaporator Coil
Standard Evaporator with Humidi-MiZer System
Alternate High-Capacity Evaporator Coil
Alternate High-Capacity Evaporator with Humidi-MiZer
CONDENSER COILS
Quantity
Total Face Area (sq ft)
EVAPORATOR COILS
Quantity
Total Face Area (sq ft)
Refrigerant Feed Device...No. per Circuit
Standard Evaporator Coils
Rows...Fins/in.
Fin Type
Tube Type
Alternate, High-Capacity Evaporator Coils
Rows...Fins/in.
Fin Type
Tube Type
HEATING SECTION
Number of Heat Exchangers
Input (MBtuh)
Output (MBtuh) (Vertical/Horizontal)
Temperature Rise Range (F)
Efficiency (%) (Vertical/Horizontal)
Burner Orifice Diameter
Quantity (in. ...drill no.)
Manifold Pressure (in. wg)
Line Pressure (in. wg) (min...max)
Firing Stages
Number of Gas Valves
CONDENSER FANS
Quantity...Diameter (in.)
Nominal Cfm
Motor Hp...Rpm
SUPPLY FAN
Nominal Cfm
Maximum Allowable Cfm
Maximum Allowable Rpm
Shaft Diameter at Pulley (in.)
SUPPLY-FAN MOTOR AND DRIVE
Motor Hp
Motor Frame Size
Efficiency at Full Load (%)
Fan Pulley Pitch Diameter (in.)
Motor Pulley Pitch Diameter (in.)
Resulting Fan Speed (rpm)
Belts Quantity...Type
Center Distance Range (in.)
OPTIONAL POWER EXHAUST
Quantity...Motor Hp
Motor Frame Size
Efficiency at Full Load (%)
Fan Pulley Pitch Diameter (in.)
Motor Pulley Pitch Diameter Range (in.)
Motor Pulley Pitch Diameter Factory Setup (in.)
Blower Shaft Diameter at Pulley (in.)
Fan Rpm Range
Factory Setup Fan Rpm
Maximum Allowable Rpm
FILTERS
Standard Efficiency Throwaway (Standard)
Quantity...Size (in.)
Medium Efficiency (30%) Pleated (Optional)
Quantity...Size (in.)
High Efficiency (90%) Bag Filters
with High Velocity Prefilters (Opt)
Quantity...Size (in.)
Bag Filter
Prefilter
Cartridge Filters with High Velocity Prefilters (Opt)
Quantity...Size (in.)
Cartridge Filter
Prefilter
OUTSIDE AIR SCREENS
Standard Hood (25%) Quantity...Size (in.)
OPTIONAL ECONOMIZER FILTER
Quantity...Size (in.)
LEGEND
MBtuh Btuh in Thousands
TXV
Thermostatic Expansion Valve
* 460-3-60 only.
See Power Exhaust Fan Drive Data table on page 28 for more information.

14

48P2,P3,P4,P5040
40
Standard Chassis
Extended Chassis

48P2,P3,P4,P5050
50
Standard Chassis
Extended Chassis

5810
5940

6310
6440

6025
6155

6525
6655

6110
6240

6610
6740

6325
6455

6825
6955

Scroll
2...ZP103/1...ZP182
110
2

2...ZP120/2...ZP137
110
2
R-410A

21.6/26.7
29.4/29.0
21.6/39.1
29.4/41.4
31.1/37.2
35.2/36.5
31.1/49.6
35.2/48.9
Aluminum Novation Heat Exchanger with Microchannel Coils
2
2
66.7
66.7
1
45.5
TXV...2
3...15.0
Double Wavy
Cross Hatched

4...15.0
Double Wavy
Cross Hatched

6...16.0
Double Wavy
Cross Hatched

6...16.0
Double Wavy
Cross Hatched

Low Heat
7
325
263/260
10-40
81/80

High Heat
14
650
527/520
25-55
81/80

Low Heat
7
325
263/260
10-40
81/80

High Heat
14
650
527/520
25-55
81/80

7 (.1285...30)
3.5
5.0...13.0
2
1

14 (.1285...30)
3.5
5.0...13.0
2
2

7 (.1285...30)
3.5
5.0...13.0
2
1

14 (.1285...30)
3.5
5.0...13.0
2
2

Propeller Type
3...30
30,000
1.0...1140

4...30
38,000
1.0...1140
Centrifugal 25 x 25 in.

14,000
20,000
900
111/16
7.5
213T
91.7
13.7
3.4
438
2...BX60
17.74-14.30
2...3.0
182T
88.5
11.0
4.1-3.1
4.1
17/16
500-656
656
1000

14,000
20,000
900
111/16

(Any motor available on any unit)


10
15
20
25
215T
254T
256T
284T
91.7
93.0
93.6
93.6
13.7
13.7
13.7
13.7
4.3
4.9
5.5
6.5
549
626
703
830
2...5VX630
2...5VX630
2...5VX630
2...5VX650
17.74-14.30
17.63...14.01
17.63...14.01
16.63...12.87
Centrifugal, 18 x 15 in. (Any motor available on any unit)
2...5.0
2...7.5
184T
213T
89.5
91.7
10.4
12
4.7-3.7
6.0-4.8
4.2
5.4
17/16
17/16
621-785
717-882
703
800
1000
1000

30*
286T
93.6
12.5
6.5
910
3...5VX630
16.63...12.87
2...10
215T
91.7
12
7.0-5.8
6.4
17/16
854-1000
927
1000

8...20 x 25 x 2, 8...20 x 20 x 2

8...20 x 25 x 2, 8...20 x 20 x 2

8...20 x 25 x 2, 8...20 x 20 x 2

8...20 x 25 x 2, 8...20 x 20 x 2

6...20 x 24 x 22, 6...20 x 20 x 22


12...16 x 20 x 2, 3...20 x 24 x 2

6...20 x 24 x 22, 6...20 x 20 x 22


12...16 x 20 x 2, 3...20 x 24 x 2

6...20 x 24 x 12, 6...20 x 20 x 12


12...16 x 20 x 2, 3...20 x 24 x 2

6...20 x 24 x 12, 6...20 x 20 x 12


12...16 x 20 x 2, 3...20 x 24 x 2

None

None
Aluminum Frame, Permanent

5...20 x 20 x 2
2...20 x 25 x 1

5...20 x 20 x 1
2...20 x 25 x 1

48P2,P3,P4,P5055-070
BASE UNIT
NOMINAL CAPACITY (tons)
OPERATING WEIGHT (lb)
Base Unit
Low Heat
High Heat
With Economizer
Low Heat
High Heat
COMPRESSORS
Quantity...Type
Oil Charge (oz) per Compressor
Number of Refrigerant Circuits
REFRIGERANT
Operating Charge (lb), Ckt 1/Ckt 2
Standard Evaporator Coil
Standard Evaporator with Humidi-MiZer System
Alternate High-Capacity Evaporator Coil
Alternate High-Capacity Evaporator with
Humidi-MiZer
CONDENSER COILS
Quantity
Total Face Area (sq ft)
EVAPORATOR COILS
Quantity
Total Face Area (sq ft)
Refrigerant Feed Device...No. per Circuit
Standard Evaporator Coils
Rows...Fins/in.
Fin Type
Tube Type
Alternate, High-Capacity Evaporator Coils
Rows...Fins/in.
Fin Type
Tube Type
HEATING SECTION
Number of Heat Exchangers
Input (MBtuh)
Output (MBtuh) (Vertical/Horizontal)
Temperature Rise Range (F)
Efficiency (%) (Vertical/Horizontal)
Burner Orifice Diameter
Quantity (in. ...drill no.)
Manifold Pressure (in. wg)
Line Pressure (in. wg) (min...max)
Firing Stages
Number of Gas Valves
CONDENSER FANS
Quantity...Diameter (in.)
Nominal Cfm
Motor Hp...Rpm
SUPPLY FAN
Nominal Cfm
Maximum Allowable Cfm
Maximum Allowable Rpm
Shaft Diameter at Pulley (in.)
SUPPLY-FAN MOTOR AND DRIVE
Motor Hp
Motor Frame Size
Efficiency at Full Load (%)
Fan Pulley Pitch Diameter (in.)
Motor Pulley Pitch Diameter (in.)
Resulting Fan Speed (rpm)
Belts Quantity...Type
Center Distance Range (in.)
OPTIONAL POWER EXHAUST*
Quantity...Motor Hp
Motor Frame Size
Efficiency at Full Load (%)
Resulting Fan Rpm
Maximum Allowable Rpm
FILTERS
Standard Efficiency Throwaway (Standard)
Quantity...Size (in.)
Medium Efficiency (30%) Pleated (Optional)
Quantity...Size (in.)
High Efficiency (90%) Bag Filters
with High Velocity Prefilters (Optional)
Quantity...Size (in.)
Bag Filter
Prefilter
Cartridge Filters with
High Velocity Prefilters (Optional)
Quantity...Size (in.)
Cartridge Filter
Prefilter
OUTSIDE AIR SCREENS
Standard Hood (25%) Quantity...Size (in.)
OPTIONAL ECONOMIZER FILTER
Quantity...Size (in.)

48P2,P3,P4,P5055
55
Standard Chassis
Extended Chassis

48P2,P3,P4,P5060
60
Standard Chassis
Extended Chassis

48P2,P3,P4,P5070
70
Standard Chassis
Extended Chassis

7810
7940

8360
8490

7865
7995

8415
8545

8205
8335

8755
8885

8340
8470

8890
9020

8395
8525

8945
9075

8735
8865

9285
9415

2...ZP137/2...ZP137
110
2

Scroll
2...ZP154/2...ZP154
110
2
R-410A

1...ZP154,1...ZP182/1...ZP154,1...ZP182
110
2

37.6/37.9
37.6/50.3
43.5/42.8
43.5/55.2

37.6/37.9
37.6/50.3
44.6/43.5
44.6/55.9

39.5/42.0
39.5/54.4
49.0/50.0
49.0/62.4

2
66.7

Aluminum Novation Heat Exchanger with Microchannel Coils


2
66.7

4
106.7

2
61.5
TXV...2
4...15
Double Wavy
Cross Hatched

4...15
Double Wavy
Cross Hatched

4...15
Double Wavy
Cross Hatched

6...16
Double Wavy
Cross Hatched
Low Heat
High Heat
14
21
650
975
525/520
787/780
10-40
20-50
81/80
81/80

6...16
Double Wavy
Cross Hatched
Low Heat
High Heat
14
21
650
975
525/520
787/780
10-40
20-50
81/80
81/80

6...16
Double Wavy
Cross Hatched
Low Heat
High Heat
14
21
650
975
525/520
787/780
10-40
20-50
81/80
81/80

14 (.1285...30)
3.5
5.0...13.0
2
2

21 (.1285...30)
3.5
5.0...13.0
2
3

4...30
36,000
1.0...1140
17,500
25,000
800
111/16
15
254T
93.0
13.7
4.5
575
2...5VX1230
48.25-44.00
2...5
184T
89.5
740
1000

14 (.1285...30)
21 (.1285...30)
14 (.1285...30)
21 (.1285...30)
3.5
3.5
3.5
3.5
5.0...13.0
5.0...13.0
5.0...13.0
5.0...13.0
2
2
2
2
2
3
2
3
Propeller Type
4...30
4...30
36,600
39,000
1.0...1140
1.0...1140
Centrifugal 30 x 27.5 in.
21,000
24,500
30,000
30,000
800
800
111/16
111/16
(Any motor available on any unit)
20
25
30
40
256T
284T
286T
S324T
93.6
93.6
93.6
94.5
13.7
13.7
15.5
16.1
5.1
5.5
5.9
6.7
651
703
711
740
2...5VX1230
2...5VX1230
2...5VX1230
3...5VX1250
48.25-44.00
48.50-44.25
48.50-44.25
48.25-44.00
Centrifugal, 18 x 15 in. (Any motor available on any unit)
2...7.5
2...10
213T
215T
91.7
91.7
820
920
1000
1000

12...20 x 25 x 2, 12...20 x 20 x 2

12...20 x 25 x 2, 12...20 x 20 x 2

12...20 x 25 x 2, 12...20 x 20 x 2

12...20 x 25 x 2, 12...20 x 20 x 2

12...20 x 25 x 2, 12...20 x 20 x 2

12...20 x 25 x 2, 12...20 x 20 x 2

6...24 x 24 x 22, 6...24 x 20 x 22


6...24 x 24 x 2, 6...20 x 24 x 2

6...24 x 24 x 22, 6...24 x 20 x 22


6...24 x 24 x 2, 6...20 x 24 x 2

6...24 x 24 x 22, 6...24 x 20 x 22


6...24 x 24 x 2, 6...20 x 24 x 2

6...24 x 24 x 12,, 6...24 x 20 x 12


6...24 x 24 x 2, 6...20 x 24 x 2

6...24 x 24 x 12,, 6...24 x 20 x 12


6...24 x 24 x 2, 6...20 x 24 x 2

6...24 x 24 x 12, 6...24 x 20 x 12


6...24 x 24 x 2, 6...20 x 24 x 2

4...25 x 16 x 1, 2...20 x 16 x 1

4...25 x 16 x 1, 2...20 x 16 x 1
Aluminum Frame, Permanent
12...16 x 25 x 1, 2...16 x 20 x 1

4...25 x 16 x 1, 2...20 x 16 x 1

12...16 x 25 x 1, 2...16 x 20 x 1

12...16 x 25 x 1, 2...16 x 20 x 1

LEGEND
MBtuh Btuh in Thousands
TXV
Thermostatic Expansion Valve
*See Power Exhaust Fan Drive Data table on page 28 for more information.

15

Physical data 48 series units (cont)


48P2,P3,P4,P5075-100
BASE UNIT
NOMINAL CAPACITY (tons)
OPERATING WEIGHT (lb)
Base Unit
Low Heat
High Heat
With Economizer
Low Heat
High Heat
COMPRESSORS
Quantity...Type
Oil Charge (oz) per Compressor
Number of Refrigerant Circuits
REFRIGERANT
Operating Charge (lb), Ckt 1/Ckt 2
Standard Evaporator Coil
Standard Evaporator with Humidi-MiZer System
Alternate High-Capacity Evaporator Coil
Alternate High-Capacity Evaporator with
Humidi-MiZer
CONDENSER COILS
Quantity
Total Face Area (sq ft)
EVAPORATOR COILS
Quantity
Total Face Area (sq ft)
Refrigerant Feed Device...No. per Circuit
Standard Evaporator Coils
Rows...Fins/in.
Fin Type
Tube Type
Alternate, High-Capacity Evaporator Coils
Rows...Fins/in.
Fin Type
Tube Type
HEATING SECTION
Number of Heat Exchangers
Input (MBtuh)
Output (MBtuh) (Vertical/Horizontal)
Temperature Rise Range (F)
Efficiency (%) (Vertical/Horizontal)
Burner Orifice Diameter
Quantity (in. ...drill no.)
Manifold Pressure (in. wg)
Line Pressure (in. wg) (Min...Max)
Number of Gas Valves
CONDENSER FAN
Quantity...Diameter (in.)
Nominal Cfm
Motor Hp (ea)...rpm
STANDARD SUPPLY FAN
Nominal Cfm
Maximum Allowable Cfm
Maximum Allowable Rpm
Shaft Diameter at Pulley (in.)
STANDARD SUPPLY-FAN MOTOR AND DRIVE
Motor Hp
Motor Frame Size
Efficiency at Full Load (%)
Fan Pulley Pitch Diameter (in.)
Motor Pulley Pitch Diameter (in.)
Resulting Fan Rpm
Belts Quantity...Type
Center Distance Range (in.)
ALTERNATE, AIRFOIL FAN
Nominal Airflow (cfm)
Maximum Allowable Airflow (cfm)
Maximum Allowable Wheel Speed (rpm)
Shaft Diameter at Pulley (in.)
ALTERNATE SUPPLY-FAN MOTOR AND DRIVE
Motor Hp
Motor Frame Size
Efficiency at Full Load (%)
Fan Pulley Pitch Diameter (in.)
Motor Pulley Pitch Diameter (in.)
Resulting Fan Rpm
Belts Quantity...Type
Center Distance Range (in.)

48P2,P3,P4,P5075
75
Standard
Extended
Chassis
Chassis

48P2,P3,P4,P5100
100
Standard
Extended
Chassis
Chassis

9065
9195

9615
9745

9665
9795

10,215
10,345

9685
9815

10,235
10,365

9595
9725

10,145
10,275

10,195
10,325

10,745
10,875

10,215
10,345

10,765
10,895

2...ZP182/2...ZP182
110
2

Scroll
3...ZP154,3...ZP154
110
2
R-410A

3...ZP154,3...ZP182
110
2

39.5/42.0
39.5/54.4
49.0/50.0
49.0/62.4

50.4/51.3
50.4/69.1
61.5/62.9
61.5/80.7

50.8/52.8
50.8/70.6
59.3/62.8
59.3/80.6

Aluminum Novation Heat Exchanger with Microchannel Coils


6
160.0

4
106.7

6
160.0

2
61.5
TXV...2
4...15
Double Wavy
Cross Hatched
6...16
Double Wavy
Cross Hatched
Low Heat
High Heat
2
3
650
975
526/520
784/780
10-40
20-50
81/80
81/80
7 (.1285...30)
3.5
5.0...13.0
2

7 (.1285...30)
3.5
5.0...13.0
3

4...30
39,000
1.0...1140
24,500
30,000
680
111/16
30
S268T
93.6
18.5
5.3
501
3...5VX1320
47.88-45.01
24,500
30,000
1846
211/16
30
S268T
93.6
9.7
7.5
1353
2...5VX1150
42.96...45.82

LEGEND
MBtuh Btuh in Thousands
TXV Thermostatic Expansion Valve
*See page 22 for high-capacity power exhaust information. See Power Exhaust
Fan Drive Data table on page 28 for more information.

16

48P2,P3,P4,P5090
90
Standard
Extended
Chassis
Chassis

4...15
Double Wavy
Cross Hatched

4...15
Double Wavy
Cross Hatched

6...16
Double Wavy
Cross Hatched
Low Heat
High Heat
2
3
650
975
526/520
784/780
10-40
20-50
81/80
81/80

6...16
Double Wavy
Cross Hatched
Low Heat
High Heat
2
3
650
975
526/520
784/780
10-40
20-50
81/80
81/80

7 (.1285...30)
7 (.1285...30)
3.5
3.5
5.0...13.0
5.0...13.0
2
3
Propeller Type
6...30
58,000
1.0...1140
Forward Curved Centrifugal 36 x 30 in.
29,750
34,000
680
111/16
(Any motor available on any unit)
40
50
S324T
S36T
94.5
94.5
18.5
18.5
5.7
6.5
539
615
4...5VX1320
4...5VX1320
47.64-44.76
47.42-44.52
Airfoil
29,750
34,000
1846
211/16

7 (.1285...30)
3.5
5.0...13.0
2

(Any motor available on any unit)


40
50
60
S324T
S36T
S364T
94.5
94.5
95.4
10.2
8.9
8.9
8.7
8.1
8.7
1493
1593
1711
2...5VX1180
3...5VX1150
3...5VX1150
42.96...45.57
42.96...45.57
42.45...45.35

7 (.1285...30)
3.5
5.0...13.0
3

6...30
58,000
1.0...1140
35,000
40,000
680
111/16
60
S364T
95.4
18.5
7.1
672
4...5VX1320
47.42-44.52
35,000
40,000
1846
211/16
75
365T
95.4
10.8
11.1
1799
3...5VX1230
42.45...45.35

48P2,P3,P4,P5075-100 (cont)
BASE UNIT
OPTIONAL POWER EXHAUST*
Quantity...Motor Hp
Motor Frame Size
Efficiency at Full Load (%)
Fan Pulley Pitch Diameter (in.)
Motor Pulley Pitch Diameter (in.)
Shaft Diameter at Pulley (in.)
Resulting Fan Rpm
Maximum Allowable Rpm
FILTERS
Standard Efficiency Throwaway (Standard)
Quantity...Size (in.)
30% and 65% Pleated (Optional)
Quantity...Size (in.)
OUTSIDE AIR SCREENS
Standard Hood (25%) Quantity...Size (in.)
OPTIONAL ECONOMIZER FILTER
Quantity...Size (in.)

48P2,P3,P4,P5075

48P2,P3,P4,P5090
Centrifugal, 18 x 15 in. (Any motor available on any unit.)
2...7.5
213T
91.7
10.6
5.0
17/16
820
1000

48P2,P3,P4,P5100

2...5
184T
89.5
10.6
4.5
17/16
740
1000

12...20 x 25 x 2, 12...20 x 20 x 2

12...20 x 25 x 2, 12...20 x 20 x 2

12...20 x 25 x 2, 12...20 x 20 x 2

12...20 x 25 x 2, 12...20 x 20 x 2

12...20 x 25 x 2, 12...20 x 20 x 2

12...20 x 25 x 2, 12...20 x 20 x 2

4...25 x 16 x 1, 2...20 x 16 x 1

4...25 x 16 x 1, 2...20 x 16 x 1
Aluminum Frame, Permanent
12...16 x 25 x 1, 2...16 x 20 x 1

4...25 x 16 x 1, 2...20 x 16 x 1

12...16 x 25 x 1, 2...16 x 20 x 1

2...10
215T
91.7
10.6
5.6
17/16
920
1000

12...16 x 25 x 1, 2...16 x 20 x 1

LEGEND
MBtuh Btuh in Thousands
TXV Thermostatic Expansion Valve
*See page 22 for high-capacity power exhaust information. See Power Exhaust
Fan Drive Data table on page 28 for more information.

17

Physical data 50 series units


50P2,P3,P4,P5030-050
BASE UNIT
NOMINAL CAPACITY (tons)
OPERATING WEIGHT (lb)
Base Unit
Vertical Discharge
Horizontal Discharge and Vertical Discharge
with Discharge Plenum
With Economizer
Vertical Discharge
Horizontal Discharge and Vertical Discharge
with Discharge Plenum
COMPRESSORS
Quantity...Type
Oil Charge (oz) per Compressor
Number of Refrigerant Circuits
REFRIGERANT
Operating Charge (lb), Ckt 1/Ckt 2
Standard Evaporator Coil
Standard Evaporator with Humidi-MiZer System
Alternate High-Capacity Evaporator Coil
Alternate High-Capacity Evaporator with Humidi-MiZer
CONDENSER COILS
Quantity
Total Face Area (sq ft)
EVAPORATOR COILS
Quantity
Total Face Area (sq ft)
Refrigerant Feed Device...No. per Circuit
Standard Evaporator Coils
Rows...Fins/in.
Fin Type
Tube Type
Alternate, High-Capacity Evaporator Coils
Rows...Fins/in.
Fin Type
Tube Type
CONDENSER FANS
Quantity...Diameter (in.)
Nominal Cfm
Motor Hp...Rpm
SUPPLY FAN
Nominal Cfm
Maximum Allowable Cfm
Maximum Allowable Rpm
Shaft Diameter at Pulley (in.)
SUPPLY-FAN MOTOR AND DRIVE
Motor Hp
Motor Frame Size
Efficiency at Full Load (%)
Fan Pulley Pitch Diameter (in.)
Motor Pulley Pitch Diameter (in.)
Resulting Fan Speed (rpm)
Belts Quantity...Type
Center Distance Range (in.)
OPTIONAL POWER EXHAUST
Quantity...Motor Hp
Motor Frame Size
Efficiency at Full Load (%)
Fan Pulley Pitch Diameter (in.)
Motor Pulley Pitch Diameter Range (in.)
Motor Pulley Pitch Diameter Factory Setup (in.)
Blower Shaft Diameter at Pulley (in.)
Fan Rpm Range
Factory Setup Fan Rpm
Maximum Allowable Rpm
FILTERS
Standard Efficiency Throwaway (Standard)
Quantity...Size (in.)
Medium Efficiency (30%) Pleated (Optional)
Quantity...Size (in.)
High Efficiency (90%) Bag Filters
with High Velocity Prefilters (Opt)
Quantity...Size (in.)
Bag Filter
Prefilter
Cartridge Filters with High Velocity Prefilters (Opt)
Quantity...Size (in.)
Cartridge Filter
Prefilter
OUTSIDE AIR SCREENS
Standard Hood (25%) Quantity...Size (in.)
OPTIONAL ECONOMIZER FILTER
Quantity...Size (in.)

TXV

50P2,P3,P4,P5030
30
Standard Chassis
Extended Chassis
4810

5310

4910

5410

5110

5610

5210

5710

5110
5410

5610
5910

5210
5510

5710
6010

Scroll
1...ZP154/1...ZP154
110
2

1...ZP182/1...ZP182
110
2
R-410A

15.4/14.8
18.4/17.6
15.4/24.9
18.4/27.7
17.2/16.0
N/A
17.2/26.1
N/A
Aluminum Novation Heat Exchanger with Microchannel Coils

1
33.3

1
33.3
1
32.1
TXV...1

3...15.0
Double Wavy
Cross Hatched

4...15.0
Double Wavy
Cross Hatched

4...15.0
Double Wavy
Cross Hatched

N/A
N/A
N/A
Propeller Type

2...30
18,000
1.0...1140

2...30
19,500
1.0...1140
Centrifugal 25 x 25 in.

10,500
15,000
900
111/16
7.5
213T
91.7
13.7
3.4
438
2...BX60
17.74-14.30
2...3.0
182T
88.5
11.0
4.1-3.1
4.1
17/16
500-656
656
1000

LEGEND
Thermostatic Expansion Valve

* 460-3-60 only.
See Power Exhaust Fan Drive Data table on page 28 for more information.

18

50P2,P3,P4,P5035
35
Standard Chassis
Extended Chassis

10,500
15,000
900
111/16

(Any motor available on any unit)


10
15
20
215T
254T
256T
91.7
93.0
93.6
13.7
13.7
13.7
4.3
4.9
5.5
549
626
703
2...5VX630
2...5VX630
2...5VX630
17.74-14.30
17.63...14.01
17.63...14.01
Centrifugal, 18 x 15 in. (Any motor available on any unit)
2...5.0
2...7.5
184T
213T
89.5
91.7
10.4
12
4.7-3.7
6.0-4.8
4.2
5.4
17/16
17/16
621-785
717-882
703
800
1000
1000

25
284T
93.6
13.7
6.5
830
2...5VX650
16.63...12.87
2...10
215T
91.7
12
7.0-5.8
6.4
17/16
854-1000
927
1000

8...20 x 25 x 2, 8...20 x 20 x 2

8...20 x 25 x 2, 8...20 x 20 x 2

8...20 x 25 x 2, 8...20 x 20 x 2

8...20 x 25 x 2, 8...20 x 20 x 2

6...20 x 24 x 22, 6...20 x 20 x 22


12...16 x 20 x 2, 3...20 x 24 x 2

6...20 x 24 x 22, 6...20 x 20 x 22


12...16 x 20 x 2, 3...20 x 24 x 2

6...20 x 24 x 12, 6...20 x 20 x 12


12...16 x 20 x 2, 3...20 x 24 x 2

6...20 x 24 x 12, 6...20 x 20 x 12


12...16 x 20 x 2, 3...20 x 24 x 2

None

None
Aluminum Frame, Permanent
5...20 x 20 x 2, 2...20 x 25 x 1
5...20 x 20 x 1, 2...20 x 25 x 1

50P2,P3,P4,P5030-050 (cont)
BASE UNIT
NOMINAL CAPACITY (tons)
OPERATING WEIGHT (lb)
Base Unit
Vertical Discharge
Horizontal Discharge and Vertical Discharge
with Discharge Plenum
With Economizer
Vertical Discharge
Horizontal Discharge and Vertical Discharge
with Discharge Plenum
COMPRESSORS
Quantity...Type
Oil Charge (oz) per Compressor
Number of Refrigerant Circuits
REFRIGERANT
Operating Charge (lb), Ckt 1/Ckt 2
Standard Evaporator Coil
Standard Evaporator with Humidi-MiZer System
Alternate High-Capacity Evaporator Coil
Alternate High-Capacity Evaporator with Humidi-MiZer
CONDENSER COILS
Quantity
Total Face Area (sq ft)
EVAPORATOR COILS
Quantity
Total Face Area (sq ft)
Refrigerant Feed Device...No. per Circuit
Standard Evaporator Coils
Rows...Fins/in.
Fin Type
Tube Type
Alternate, High-Capacity Evaporator Coils
Rows...Fins/in.
Fin Type
Tube Type
CONDENSER FANS
Quantity...Diameter (in.)
Nominal Cfm
Motor Hp...Rpm
SUPPLY FAN
Nominal Cfm
Maximum Allowable Cfm
Maximum Allowable Rpm
Shaft Diameter at Pulley (in.)
SUPPLY-FAN MOTOR AND DRIVE
Motor Hp
Motor Frame Size
Efficiency at Full Load (%)
Fan Pulley Pitch Diameter (in.)
Motor Pulley Pitch Diameter (in.)
Resulting Fan Speed (rpm)
Belts Quantity...Type
Center Distance Range (in.)
OPTIONAL POWER EXHAUST
Quantity...Motor Hp
Motor Frame Size
Efficiency at Full Load (%)
Fan Pulley Pitch Diameter (in.)
Motor Pulley Pitch Diameter Range (in.)
Motor Pulley Pitch Diameter Factory Setup (in.)
Blower Shaft Diameter at Pulley (in.)
Fan Rpm Range
Factory Setup Fan Rpm
Maximum Allowable Rpm
FILTERS
Standard Efficiency Throwaway (Standard)
Quantity...Size (in.)
Medium Efficiency (30%) Pleated (Optional)
Quantity...Size (in.)
High Efficiency (90%) Bag Filters with High Velocity
Prefilters (Optional)
Quantity...Size (in.)
Bag Filter
Prefilter
Cartridge Filters with High Velocity Prefilters (Opt)
Quantity...Size (in.)
Cartridge Filter
Prefilter
OUTSIDE AIR SCREENS
Standard Hood (25%) Quantity...Size (in.)
OPTIONAL ECONOMIZER FILTER
Quantity...Size (in.)
TXV

50P2,P3,P4,P5040
40
Standard Chassis
Extended Chassis

50P2,P3,P4,P5050
50
Standard Chassis
Extended Chassis

5310

5810

5525

6025

5610

6110

5825

6325

5610

6110

5825

6325

5910

6410

6125

6625

Scroll
2...ZP103/1...ZP182
110
2

2...ZP120/2...ZP137
110
2
R-410A

21.6/26.7
29.4/29.0
21.6/39.1
29.4/41.4
31.1/37.2
35.2/36.5
31.1/49.6
35.2/48.9
Aluminum Novation Heat Exchanger with Microchannel Coils
2
2
66.7
66.7
1
45.5
TXV...2
3...15.0
Double Wavy
Cross Hatched

4...15.0
Double Wavy
Cross Hatched

6...16.0
Double Wavy
Cross Hatched

6...16.0
Double Wavy
Cross Hatched
Propeller Type

3...30
30,000
1.0...1140

4...30
38,000
1.0...1140
Centrifugal 25 x 25 in.

14,000
20,000
900
111/16
7.5
213T
91.7
13.7
3.4
438
2...BX60
17.74-14.30
2...3.0
182T
88.5
11.0
4.1-3.1
4.1
17/16
500-656
656
1000

14,000
20,000
900
111/16

(Any motor available on any unit)


10
15
20
25
215T
254T
256T
284T
91.7
93.0
93.6
93.6
13.7
13.7
13.7
13.7
4.3
4.9
5.5
6.5
549
626
703
830
2...5VX630
2...5VX630
2...5VX630
2...5VX650
17.74-14.30
17.63...14.01
17.63...14.01
16.63...12.87
Centrifugal, 18 x 15 in. (Any motor available on any unit)
2...5.0
2...7.5
184T
213T
89.5
91.7
10.4
12
4.7-3.7
6.0-4.8
4.2
5.4
17/16
17/16
621-785
717-882
703
800
1000
1000

30*
286T
93.6
12.5
6.5
910
3...5VX630
16.63...12.87
2...10
215T
91.7
12
7.0-5.8
6.4
17/16
854-1000
927
1000

8...20 x 25 x 2, 8...20 x 20 x 2

8...20 x 25 x 2, 8...20 x 20 x 2

8...20 x 25 x 2, 8...20 x 20 x 2

8...20 x 25 x 2, 8...20 x 20 x 2

6...20 x 24 x 22, 6...20 x 20 x 22


12...16 x 20 x 2, 3...20 x 24 x 2

6...20 x 24 x 22, 6...20 x 20 x 22


12...16 x 20 x 2, 3...20 x 24 x 2

6...20 x 24 x 12, 6...20 x 20 x 12


12...16 x 20 x 2, 3...20 x 24 x 2

6...20 x 24 x 12, 6...20 x 20 x 12


12...16 x 20 x 2, 3...20 x 24 x 2

None

None
Aluminum Frame, Permanent
5...20 x 20 x 2, 2...20 x 25 x 1
5...20 x 20 x 1, 2...20 x 25 x 1

LEGEND
Thermostatic Expansion Valve

* 460-3-60 only.
See Power Exhaust Fan Drive Data table on page 28 for more information.

19

Physical data 50 series units (cont)


50P2,P3,P4,P5055-070
BASE UNIT
NOMINAL CAPACITY (tons)
OPERATING WEIGHT (lb)
Base Unit
Vertical Discharge
Horizontal Discharge and Vertical Discharge
with Discharge Plenum
With Economizer
Vertical Discharge
Horizontal Discharge and Vertical Discharge
with Discharge Plenum
COMPRESSORS
Quantity...Type
Oil Charge (oz) per Compressor
Number of Refrigerant Circuits
REFRIGERANT
Operating Charge (lb), Ckt 1/Ckt 2
Standard Evaporator Coil
Standard Evaporator with Humidi-MiZer
System
Alternate High-Capacity Evaporator Coil
Alternate High-Capacity Evaporator with
Humidi-MiZer
CONDENSER COILS
Quantity
Total Face Area (sq ft)
EVAPORATOR COILS
Quantity
Total Face Area (sq ft)
Refrigerant Feed Device...No. per Circuit
Standard Evaporator Coils
Rows...Fins/in.
Fin Type
Tube Type
Alternate, High-Capacity Evaporator Coils
Rows...Fins/in.
Fin Type
Tube Type
CONDENSER FANS
Quantity...Diameter (in.)
Nominal Cfm
Motor Hp...Rpm
SUPPLY FAN
Nominal Cfm
Maximum Allowable Cfm
Maximum Allowable Rpm
Shaft Diameter at Pulley (in.)
SUPPLY-FAN MOTOR AND DRIVE
Motor Hp
Motor Frame Size
Efficiency at Full Load (%)
Fan Pulley Pitch Diameter (in.)
Motor Pulley Pitch Diameter (in.)
Resulting Fan Speed (rpm)
Belts Quantity...Type
Center Distance Range (in.)
OPTIONAL POWER EXHAUST
Quantity...Motor Hp
Motor Frame Size
Efficiency at Full Load (%)
Resulting Fan Rpm
Maximum Allowable Rpm
FILTERS
Standard Efficiency Throwaway (Standard)
Quantity...Size (in.)
Medium Efficiency (30%) Pleated (Optional)
Quantity...Size (in.)
High Efficiency (90%) Bag Filters
with High Velocity Prefilters (Optional)
Quantity...Size (in.)
Bag Filter
Prefilter
Cartridge Filters
with High Velocity Prefilters (optional)
Quantity...Size (in.)
Cartridge Filter
Prefilter
OUTSIDE AIR SCREENS
Standard Hood (25%) Quantity...Size (in.)

50P2,P3,P4,P5055
55
Standard Chassis Extended Chassis

TXV

7370

6875

7425

7215

7765

7370

7920

7425

7975

7765

8315

7350
7900

7900
8450

7405
7955

7955
8505

7745
8295

8295
8845

2...ZP137/2...ZP137
110
2

Scroll
2...ZP154/2...ZP154
110
2
R-410A

1...ZP154,1...ZP182/1...ZP154,1...ZP182
110
2

37.6/37.9

37.6/37.9

39.5/42.0

37.6/50.3

37.6/50.3

39.5/54.4

43.5/42.8
43.5/55.2

44.6/43.5
44.6/55.9

49.0/50.0
49.0/62.4

2
66.7

Aluminum Novation Heat Exchanger with Microchannel Coils


2
66.7

4
106.7

2
61.5
TXV...2
4...15
Double Wavy
Cross Hatched
6...16
Double Wavy
Cross Hatched
4...30
36,000
1.0...1140
17,500
25,000
800
111/16
15
254T
93.0
13.7
4.5
575
2...5VX1230
48.25-44.00
2...5
184T
89.5
740
1000

4...15
Double Wavy
Cross Hatched

4...15
Double Wavy
Cross Hatched

6...16
6...16
Double Wavy
Double Wavy
Cross Hatched
Cross Hatched
Propeller Type
4...30
4...30
36,600
39,000
1.0...1140
1.0...1140
Centrifugal 30 x 27.5 in.
21,000
24,500
30,000
30,000
800
800
111/16
111/16
(Any motor available on any unit)
20
25
30
40*
256T
284T
286T
S324T
93.6
93.6
93.6
94.5
13.7
13.7
15.5
16.1
5.1
5.5
5.9
6.7
651
703
711
740
2...5VX1230
2...5VX1230
2...5VX1230
3...5VX1250
48.25-44.00
48.50-44.25
48.50-44.25
48.25-44.00
Centrifugal, 18 x 15 in. (Any motor available on any unit)
2...7.5
2...10
213T
215T
91.7
91.7
820
920
1000
1000

12...20 x 25 x 2, 12...20 x 20 x 2

12...20 x 25 x 2, 12...20 x 20 x 2

12...20 x 25 x 2, 12...20 x 20 x 2

12...20 x 25 x 2, 12...20 x 20 x 2

12...20 x 25 x 2, 12...20 x 20 x 2

12...20 x 25 x 2, 12...20 x 20 x 2

6...24 x 24 x 22, 6...24 x 20 x 22


6...24 x 24 x 2, 6...20 x 24 x 2

6...24 x 24 x 22, 6...24 x 20 x 22


6...24 x 24 x 2, 6...20 x 24 x 2

6...24 x 24 x 22, 6...24 x 20 x 22


6...24 x 24 x 2, 6...20 x 24 x 2

6...24 x 24 x 12,, 6...24 x 20 x 12


6...24 x 24 x 2, 6...20 x 24 x 2

6...24 x 24 x 12, 6...24 x 20 x 12


6...24 x 24 x 2, 6...20 x 24 x 2

6...24 x 24 x 12, 6...24 x 20 x 12


6...24 x 24 x 2, 6...20 x 24 x 2

4...25 x 16 x 1
2...20 x 16 x 1

4...25 x 16 x 1
2...20 x 16 x 1
Aluminum Frame, Permanent
12...16 x 25 x 1
2...16 x 20 x 1

4...25 x 16 x 1
2...20 x 16 x 1

12...16 x 25 x 1
2...16 x 20 x 1

LEGEND
Thermostatic Expansion Valve

* 460-3-60 and 575-3-60 only.


See Power Exhaust Fan Drive Data table on page 28 for more information.

20

50P2,P3,P4,P5070
70
Standard Chassis Extended Chassis

6820

OPTIONAL ECONOMIZER FILTER


Quantity...Size (in.)

50P2,P3,P4,P5060
60
Standard Chassis Extended Chassis

12...16 x 25 x 1
2...16 x 20 x 1

50P2,P3,P4,P5075-100
BASE UNIT
NOMINAL CAPACITY (tons)
OPERATING WEIGHT (lb)
Base Unit
Vertical Discharge
Horizontal Discharge and Vertical Discharge
with Discharge Plenum
With Economizer
Vertical Discharge
Horizontal Discharge and Vertical Discharge
with Discharge Plenum
COMPRESSORS
Quantity...Type
Oil Charge (oz) per Compressor
Number of Refrigerant Circuits
REFRIGERANT
Operating Charge (lb), Ckt 1/Ckt 2
Standard Evaporator Coil
Standard Evaporator with Humidi-MiZer System
Alternate High-Capacity Evaporator Coil
Alternate High-Capacity Evaporator with
Humidi-MiZer
CONDENSER COILS
Quantity
Total Face Area (sq ft)
EVAPORATOR COILS
Quantity
Total Face Area (sq ft)
Refrigerant Feed Device...No. per Circuit
Standard Evaporator Coils
Rows...Fins/in.
Fin Type
Tube Type
Alternate, High-Capacity Evaporator Coils
Rows...Fins/in.
Fin Type
Tube Type
CONDENSER FAN
Quantity...Diameter (in.)
Nominal Cfm
Motor Hp (ea)...rpm
STANDARD SUPPLY FAN
Nominal Cfm
Maximum Allowable Cfm
Maximum Allowable Rpm
Shaft Diameter at Pulley (in.)
STANDARD SUPPLY-FAN MOTOR AND DRIVE
Motor Hp
Motor Frame Size
Efficiency at Full Load (%)
Fan Pulley Pitch Diameter (in.)
Motor Pulley Pitch Diameter (in.)
Resulting Fan Rpm
Belts Quantity...Type
Center Distance Range (in.)
ALTERNATE, AIRFOIL FAN
Nominal Airflow (cfm)
Maximum Allowable Airflow (cfm)
Maximum Allowable Wheel Speed (rpm)
Shaft Diameter at Pulley (in.)
ALTERNATE SUPPLY-FAN MOTOR AND DRIVE
Motor Hp
Motor Frame Size
Efficiency at Full Load (%)
Fan Pulley Pitch Diameter (in.)
Motor Pulley Pitch Diameter (in.)
Resulting Fan Rpm
Belts Quantity...Type
Center Distance Range (in.)
OPTIONAL POWER EXHAUST*
Quantity...Motor Hp
Motor Frame Size
Efficiency at Full Load (%)
Fan Pulley Pitch Diameter (in.)
Motor Pulley Pitch Diameter (in.)
Shaft Diameter at Pulley (in.)
Resulting Fan Rpm
Maximum Allowable Rpm
FILTERS
Standard Efficiency Throwaway (Standard)
Quantity...Size (in.)
30% and 65% Pleated (Optional)
Quantity...Size (in.)
OUTSIDE AIR SCREENS
Standard Hood (25%) Quantity...Size (in.)
OPTIONAL ECONOMIZER FILTER
Quantity...Size (in.)

TXV

50P2,P3,P4,P5075
75

50P2,P3,P4,P5090
90

50P2,P3,P4,P5100
100

Standard
Chassis

Extended
Chassis

Standard
Chassis

Extended
Chassis

Standard
Chassis

Extended
Chassis

8665

9215

9265

9815

9285

9835

9195

9745

9795

10,345

9815

10,365

2...ZP182/2...ZP182
110
2

Scroll
3...ZP154,3...ZP154
110
2
R-410A

3...ZP154,3...ZP182
110
2

39.5/42.0
39.5/54.4
49.0/50.0
49.0/62.4

50.4/51.3
50.4/69.1
61.5/62.9
61.5/80.7

50.8/52.8
50.8/70.6
59.3/62.8
59.3/80.6

4
106.7

Aluminum Novation Heat Exchanger with Microchannel Coils


6
160.0

6
160.0

2
61.5
TXV...2
4...15
Double Wavy
Cross Hatched
6...16
Double Wavy
Cross Hatched
4...30
39,000
1.0...1140
24,500
30,000
680
111/16
30
S268T
93.6
18.5
5.3
501
3...5VX1320
47.88-45.01
24,500
30,000
1846
211/16
30
S268T
93.6
9.7
7.5
1353
2...5VX1150
42.96...45.82
2...5
184T
89.5
10.6
4.5
17/16
740
1000
12...20 x 25 x 2
12...20 x 20 x 2
12...20 x 25 x 2
12...20 x 20 x 2
4...25 x 16 x 1
2...20 x 16 x 1
12...16 x 25 x 1
2...16 x 20 x 1

4...15
Double Wavy
Cross Hatched
6...16
Double Wavy
Cross Hatched
Propeller Type
6...30
58,000
1.0...1140
Forward Curved Centrifugal 36 x 30 in.
29,750
34,000
680
111/16
(Any motor available on any unit)
40
50
S324T
S36T
94.5
94.5
18.5
18.5
5.7
6.5
539
615
4...5VX1320
4...5VX1320
47.64-44.76
47.42-44.52
Airfoil
29,750
34,000
1846
211/16
(Any motor available on any unit)
40
50
60
S324T
S36T
S364T
94.5
94.5
95.4
10.2
8.9
8.9
8.7
8.1
8.7
1493
1593
1711
2...5VX1180
3...5VX1150
3...5VX1150
42.96...45.57
42.96...45.57
42.45...45.35
Centrifugal, 18 x 15 in. (Any motor available on any unit.)
2...7.5
213T
91.7
10.6
5.0
17/16
820
1000
12...20 x 25 x 2
12...20 x 20 x 2
12...20 x 25 x 2
12...20 x 20 x 2
4...25 x 16 x 1
2...20 x 16 x 1
Aluminum Frame, Permanent
12...16 x 25 x 1
2...16 x 20 x 1

4...15
Double Wavy
Cross Hatched
6...16
Double Wavy
Cross Hatched
6...30
58,000
1.0...1140
35,000
40,000
680
111/16
60
S364T
95.4
18.5
7.1
672
4...5VX1320
47.42-44.52
35,000
40,000
1846
211/16
75
365T
95.4
10.8
11.1
1799
3...5VX1230
42.45...45.35
2...10
215T
91.7
10.6
5.6
17/16
920
1000
12...20 x 25 x 2
12...20 x 20 x 2
12...20 x 25 x 2
12...20 x 20 x 2
4...25 x 16 x 1
2...20 x 16 x 1
12...16 x 25 x 1
2...16 x 20 x 1

LEGEND
Thermostatic Expansion Valve

* See page 22 for high-capacity power exhaust information. See Power Exhaust
Fan Drive Data table on page 28 for more information.

21

Physical data (cont)


OPTIONAL HYDRONIC HEAT COIL
UNIT SIZE 50P
COIL CONSTRUCTION
FACE AREA (sq ft)
ROWS...FINS PER INCH
CIRCUIT ARRANGEMENT
CONNECTIONS (Qty) Dim
Supply (in.)
Return (in.)

030-050
055-100
-in. OD copper tubes, aluminum plate fins, galvanized steel frame
22.6
(2) sections: total 27.1
28
211
Half
Half
(1) 21/2 NPT
(1) 21/2 NPT

(2) 11/2 NPT


(2) 11/2 NPT

Steel
0.5272

Steel
0.6327

HEADER MATERIAL
INTERNAL VOLUME (cu ft)

OPTIONAL RETURN/EXHAUST FAN (48/50P075-100 Only)


RETURN/EXHAUST FAN
Quantity...Motor Hp
Motor Frame Size
Efficiency at Full Load (%)
Fan Pulley Pitch Diameter (in.)
Motor Pulley Pitch Diameter (in.)
Shaft Diameter at Pulley (in.)
Resulting Fan Rpm
Maximum Allowable Rpm

1...20
256T
93.6
8.5
5.3
215/16
1104
1447

Plenum Fan, 47.13 in. (Any motor available on any unit.)


1...25
1...30
284T
286T
93.6
93.6
9.8
8.5
6.7
6.1
215/16
215/16
1209
1271
1447
1447

1...40
324T
93.8
8.5
6.7
215/16
1396
1447

OPTIONAL HIGH-CAPACITY POWER EXHAUST (48/50P075-100 Only)


Centrifugal, 22 x 20 in., 111/16 in. shaft diameter (Any motor available on any unit)
20
30
40
50
60
2...10
2...15
2...20
2...25
2...30
S215T
D254T
S256T
S284T
S286T
91.7
93
93.6
93.6
93.6
12.4
12.4
11.1
11.1
11.1
4.8
5.8
5.9
6.5
6.9
714
841
928
1020
1094
1175
1175
1175
1175
1175
2...BX93
2...BX93
2...5VX950
2...5VX950
2...5VX950

POWER EXHAUST
Total Hp
Quantity...Motor Hp
Motor Frame Size
Efficiency at Full Load (%)
Fan Sheave Pitch Diameter (in.)
Motor Sheave Pitch Diameter (in.)
Resulting Fan Rpm
Maximum Allowable Rpm
Belts Quantity...Type

OPTIONAL HUMIDI-MIZER ADAPTIVE DEHUMIFICATION SYSTEM


UNIT SIZE 48/50P
COIL CONSTRUCTION
Quantity
FACE AREA (sq ft)

030-075
090,100
Aluminum Novation Heat Exchanger with Microchannel Coil Technology
1
1
26.7
33.3

STAGING SEQUENCES
SIZES 030,035
STAGE
COMP
A1
B1
UNIT
030
035

SEQUENCE
1*
1
Compressor Status
ON
ON
OFF
OFF
Capacity 48/50P
36%
50%
38%
50%

0
OFF
OFF
0%
0%

SIZE 040 WITH MINIMUM LOAD VALVE


2
ON
ON
100%
100%

*Minimum load valve.

COMP
A1*
B1
UNIT
030
035

0
OFF
OFF
0%
0%

SEQUENCE
1
2
Compressor Status
ON
ON
OFF
ON
Capacity 48/50P
25% to 50%
75% to 100%
25% to 50%
75% to 100%

*On units with optional digital scroll compressor, compressor A1 modulates from minimum to maximum capacity to provide increased stages.

22

COMP
A1
B1
B2
UNIT
040

1*

OFF
OFF
OFF

ON
OFF
OFF

0%

36%

SEQUENCE
1
2
Compressor Status
ON
ON
OFF
ON
OFF
OFF
Capacity 48/50P
47%
73%

3
ON
ON
ON
100%

*Minimum load valve.

SIZES 030,035 WITH DIGITAL COMPRESSOR


STAGE

STAGE

SIZE 040 WITH DIGITAL COMPRESSOR


STAGE
COMP
A1*
B1
B2
UNIT
040

0
OFF
OFF
OFF
0%

SEQUENCE
1
2
Compressor Status
ON
ON
OFF
ON
OFF
OFF
Capacity 48/50P
23% to 47% 50% to 73%

3
ON
ON
ON
77% to 100%

*On units with optional digital scroll compressor, compressor A1 modulates from minimum to maximum capacity to provide increased stages.

STAGING SEQUENCES (cont)


SIZE 040 WITHOUT MINIMUM LOAD VALVE
STAGE
COMP
A1
B1
B2
UNIT
040

OFF
OFF
OFF

OFF
ON
OFF

0%

27%

SEQUENCE
2
3
Compressor Status
ON
ON
OFF
ON
OFF
OFF
Capacity 48/50P
47%
73%

SIZES 050-075
4

ON
ON
ON
100%

STAGE
COMP
A1
A2
B1
B2
UNIT
050
055
060
070
075

1*

OFF
OFF
OFF
OFF

ON
OFF
OFF
OFF

0%
0%
0%
0%
0%

15%
17%
18%
16%
19%

SEQUENCE
1
2
Compressor Status
ON
ON
OFF
OFF
OFF
ON
OFF
OFF
Capacity 48/50P
23%
50%
25%
50%
25%
50%
23%
46%
25%
50%

ON
ON
ON
OFF

ON
ON
ON
ON

73%
75%
75%
73%
75%

100%
100%
100%
100%
100%

*Minimum load valve.

SIZES 050-075 WITH DIGITAL COMPRESSOR


STAGE
COMP
A1*
A2
B1
B2
UNIT
050
055
060
070
075

OFF
OFF
OFF
OFF

ON
OFF
OFF
OFF

0%
0%
0%
0%
0%

12% to 23%
13% to 25%
13% to 25%
11% to 23%
13% to 25%

SEQUENCE
2
Compressor Status
ON
OFF
ON
OFF
Capacity 48/50P
38% to 50%
38% to 50%
38% to 50%
34% to 46%
38% to 50%

ON
ON
ON
OFF

ON
ON
ON
ON

62% to 73%
63% to 75%
63% to 75%
61% to 73%
63% to 75%

88% to 100%
88% to 100%
88% to 100%
89% to 100%
88% to 100%

*On units with optional digital scroll compressor, compressor A1 modulates from minimum to maximum capacity to provide increased stages.

SIZES 090-100
STAGE
COMP
A1
A2
A3
B1
B2
B3
UNIT
090
100

1*

OFF
OFF
OFF
OFF
OFF
OFF

ON
OFF
OFF
OFF
OFF
OFF

ON
OFF
OFF
OFF
OFF
OFF

0%
0%

12%
11%

17%
15%

SEQUENCE
2
3
Compressor Status
ON
ON
OFF
ON
OFF
OFF
ON
ON
OFF
OFF
OFF
OFF
Capacity 48/50P
33%
50%
33%
49%

ON
ON
OFF
ON
ON
OFF

ON
ON
ON
ON
ON
OFF

ON
ON
ON
ON
ON
ON

67%
67%

83%
82%

100%
100%

*Minimum load valve.

SIZES 090-100 WITH DIGITAL COMPRESSOR


STAGE
COMP
A1*
A2
A3
B1
B2
B3
UNIT
090
100

OFF
OFF
OFF
OFF
OFF
OFF

ON
OFF
OFF
OFF
OFF
OFF

ON
OFF
OFF
ON
OFF
OFF

0%
0%

8% to 17%
8% to 15%

25% to 33%
26% to 33%

SEQUENCE
3
4
Compressor Status
ON
ON
ON
ON
OFF
OFF
ON
ON
OFF
ON
OFF
OFF
Capacity 48/50P
42% to 50%
58% to 67%
41% to 49%
59% to 67%

ON
ON
ON
ON
ON
OFF

ON
ON
ON
ON
ON
ON

75% to 83%
74% to 82%

92% to 100%
92% to 100%

*On units with optional digital scroll compressor, compressor A1 modulates from minimum to maximum capacity to provide increased stages.

23

Physical data (cont)


WEIGHT DISTRIBUTION AND CENTER OF GRAVITY 48 SERIES UNITS
4

B
2

1
A

48P2,P3,P4,P5 UNITS
Vertical Supply/Return
Horizontal Supply/Return
Low Heat
No Extended Chassis

Vertical Supply/Return
Horizontal Supply/Return
High Heat
No Extended Chassis

Vertical Supply/Return
Horizontal Supply/Return
Low Heat
with Extended Chassis

Vertical Supply/Return
Horizontal Supply/Return
High Heat
with Extended Chassis

48P2,P3,P4,P5 UNITS WITH


OPTIONAL HIGH-CAPACITY POWER EXHAUST
Vertical Supply/Return
Horizontal Supply/Return
Low Heat
Vertical Supply/Return
Horizontal Supply/Return
High Heat
Vertical Supply/Return
Horizontal Supply/Return
Low Heat with Extended Chassis
Vertical Supply/Return
Horizontal Supply/Return
High Heat with Extended Chassis

SIZE
030
035
040
050
055
060
070
075
090
100
030
035
040
050
055
060
070
075
090
100
030
035
040
050
055
060
070
075
090
100
030
035
040
050
055
060
070
075
090
100

SIZE
075
090
100
075
090
100
075
090
100
075
090
100

1
2002
2056
1983
2079
2408
2417
2950
3385
3255
3248
2034
2088
2013
2108
2443
2452
2991
3444
3307
3303
2166
2223
2148
2244
2558
2567
3117
3551
3419
3409
2197
2253
2177
2272
2592
2602
3158
3610
3471
3463

CORNER WEIGHTS (lb)


2
3
1009
1008
1031
1029
1374
1372
1386
1384
2205
2202
2223
2220
2450
1913
2604
2033
2911
2407
2929
2422
1042
1041
1064
1062
1410
1408
1422
1420
2236
2233
2254
2250
2481
1937
2618
2044
2931
2424
2946
2436
1096
1094
1114
1112
1460
1458
1471
1469
2331
2328
2349
2346
2541
2023
2747
2145
3048
2521
3070
2538
1130
1129
1148
1147
1496
1494
1508
1506
2361
2358
2379
2376
2623
2048
2761
2156
3068
2537
3086
2552

1
4171
4004
4002
4230
4058
4054
6905
6484
6620
6969
6541
6679

CORNER WEIGHTS (lb)


2
3
3410
2662
3712
3070
3726
3081
3424
2673
3730
3084
3745
3097
984
768
1534
1268
1409
1165
993
776
1547
1280
1422
1176

4
2000
2053
1981
2076
2404
2414
2303
2643
2691
2686
2032
2085
2010
2105
2439
2449
2335
2689
2734
2731
2163
2220
2145
2241
2554
2563
2434
2773
2827
2819
2194
2250
2174
2269
2589
2598
2466
2818
2870
2864

TOTAL
(lb)
6,019
6,169
6,710
6,925
9,220
9,275
9,615
10,665
11,265
11,285
6,149
6,299
6,840
7,055
9,350
9,405
9,745
10,795
11,395
11,415
6,519
6,669
7,210
7,425
9,770
9,825
10,165
11,215
11,815
11,835
6,649
6,799
7,340
7,555
9,900
9,955
10,295
11,345
11,945
11,965

A
in.
170 5/8
170 7/8
198 1/4
201 1/4
228 7/8
228 1/2
244 5/8
253 1/8
261
260
169 3/4
170
197 3/8
200 3/8
229
228 1/2
244 3/4
254 3/8
262 1/8
261 1/4
187 1/8
187 3/4
214 3/4
217 7/8
242 5/8
242 1/8
258 7/8
266 3/4
274 5/8
273 3/8
186 1/8
186 5/8
213 3/4
216 7/8
242 3/4
242 1/4
258 1/2
268
275 3/4
274 3/4

B
in.
45 7/8
45 7/8
45 7/8
45 7/8
45 7/8
45 7/8
40 1/4
40 1/4
41 1/2
41 1/2
45 7/8
45 7/8
45 7/8
45 7/8
45 7/8
45 7/8
40 1/4
40 1/4
41 1/2
41 1/2
45 7/8
45 7/8
45 7/8
45 7/8
45 7/8
45 7/8
40 1/4
40 1/4
41 1/2
41 1/2
45 7/8
45 7/8
45 7/8
45 7/8
45 7/8
45 7/8
40 1/4
40 1/4
41 1/2
41 1/2

4
3256
3311
3309
3302
3356
3352
5391
5362
5474
5441
5409
5523

TOTAL
(lb)
13,499
14,097
14,119
13,629
14,227
14,249
14,049
14,647
14,669
14,179
14,777
14,799

A
in.
290
297 5/8
297 1/8
291 3/8
299
298 1/4
483 1/2
484 3/8
493 3/4
483 1/2
484 1/4
493 3/4

B
in.
40 1/4
41 1/2
41 1/2
40 1/4
41 1/2
41 1/2
40 1/4
41 1/2
41 1/2
40 1/4
41 1/2
41 1/2

NOTE: The weight distribution and center of gravity information include the impact of an economizer, the largest indoor fan motor, and a VFD (variable frequency
drive). On units with a return fan or high-capacity power exhaust, the largest motors and VFD are also included. These weights do not include the impact of other
factory-installed options such as barometric relief, power exhaust, high-capacity indoor coil, hot water coil, or indoor fan.

24

WEIGHT DISTRIBUTION AND CENTER OF GRAVITY 48 SERIES UNITS (cont)


4

B
2

1
A

48P2,P3,P4,P5 UNITS
WITH OPTIONAL RETURN/EXHAUST FAN
Vertical Supply/Return
Horizontal Supply/Return
Low Heat
Vertical Supply/Return
Horizontal Supply/Return
High Heat
Vertical Supply/Return
Horizontal Supply/Return
Low Heat with Extended Chassis
Vertical Supply/Return
Horizontal Supply/Return
High Heat with Extended Chassis

SIZE
075
090
100
075
090
100
075
090
100
075
090
100

1
3470
3327
3302
3543
3377
3370
3609
3467
3437
3681
3517
3505

CORNER WEIGHTS (lb)


2
3
3449
2693
3745
3097
3782
3127
3449
2693
3767
3115
3785
3130
3618
2825
3906
3230
3948
3264
3620
2826
3928
3248
3951
3267

4
2709
2751
2730
2766
2793
2787
2818
2867
2842
2874
2908
2898

TOTAL
(lb)
12,321
12,921
12,941
12,451
13,051
13,071
12,871
13,471
13,491
13,001
13,601
13,621

A
in.
224 5/8
232 5/8
230 3/8
226 7/8
233 3/4
232 7/8
236 1/4
244 1/4
241 3/4
238 1/2
245 3/8
244 1/4

B
in.
40 1/4
41 1/2
41 1/2
40 1/4
41 1/2
41 1/2
40 1/4
41 1/2
41 1/2
40 1/4
41 1/2
41 1/2

NOTE: The weight distribution and center of gravity information include the impact of an economizer, the largest indoor fan motor, and a VFD (variable frequency
drive). On units with a return fan or high-capacity power exhaust, the largest motors and VFD are also included. These weights do not include the impact of other
factory-installed options such as barometric relief, power exhaust, high-capacity indoor coil, hot water coil, or indoor fan.

WEIGHT DISTRIBUTION AND CENTER OF GRAVITY 50 SERIES UNITS


3

B
2

1
A

50P2,P3,P4,P5 UNITS
50P2,P3 Vertical Supply/Return
No Discharge Plenum
No Extended Chassis

50P2,P3 Vertical Supply/Return


50P4,P5 Horizontal Supply/Return
No Discharge Plenum, No Extended Chassis
50P2,P3 Vertical Supply/Return
with Discharge Plenum and No Extended Chassis
50P4,P5 Horizontal Supply/Return
with No Extended Chassis

SIZE
030
035
040
050
055
060
070
075
090
100
030
035
040
050
055
060
070

1
1848
1901
1826
1921
2204
2215
2984
3219
3108
3101
1727
1770
1749
1842
2321
2331
2847

CORNER WEIGHTS (lb)


2
3
914
913
935
934
1281
1279
1293
1291
1914
1911
1930
1928
1860
1452
2545
1987
2839
2348
2857
2363
1184
1183
1217
1215
1508
1506
1523
1521
2072
2069
2089
2087
2305
1800

4
1845
1898
1824
1919
2201
2212
2329
2514
2570
2564
1725
1768
1746
1839
2318
2328
2223

TOTAL
(lb)
5,519
5,669
6,210
6,425
8,230
8,285
8,625
10,265
10,865
10,885
5,819
5,969
6,510
6,725
8,780
8,835
9,175

A
in.
159 1/8
159 3/8
186 1/8
189 1/4
212 5/8
212 1/4
250 1/2
250 1/8
258 3/8
257 1/4
152 1/4
152 1/8
180 1/8
183 5/8
231 3/4
231 1/4
247 1/2

B
in.
45 7/8
45 7/8
45 7/8
45 7/8
45 7/8
45 7/8
40 1/4
40 1/4
41 1/2
41 1/2
45 7/8
45 7/8
45 7/8
45 7/8
45 7/8
45 7/8
40 1/4

NOTE: The weight distribution and center of gravity information include the impact of an economizer, the largest indoor fan motor, and a VFD (variable frequency
drive). On units with a return fan or high-capacity power exhaust, the largest motors and VFD are also included. These weights do not include the impact of other
factory-installed options such as barometric relief, power exhaust, high-capacity indoor coil, hot water coil, or indoor fan.

25

Physical data (cont)


WEIGHT DISTRIBUTION AND CENTER OF GRAVITY 50 SERIES UNITS (cont)
3

B
2

1
A

50P2,P3,P4,P5 UNITS
50P2,P3 Vertical Supply/Return
with Extended Chassis

50P2,P3 Vertical Supply/Return with Extended Chassis


50P4,P5 Horizontal Supply/Return with Extended Chassis
50P2,P3 Vertical Supply/Return
with Extended Chassis and Discharge Plenum
50P4,P5 Horizontal Supply/Return
with Extended Chassis

50P2,P3,P4,P5 UNITS WITH OPTIONAL RETURN FAN


50P2,P3 Vertical Supply/Return
50P4,P5 Horizontal Supply/Vertical Return
50P2,P3 Vertical Supply/Return with Extended Chassis
50P4,P5 Horizontal Supply/Vertical Return with Extended
Chassis
50P2,P3,P4,P5 UNITS
WITH OPTIONAL HIGH-CAPACITY POWER EXHAUST
50P2,P3 Vertical Supply/Return
50P4,P5 Horizontal Supply/Vertical Return
50P2,P3 Vertical Supply/Return with Extended Chassis
50P4,P5 Horizontal Supply/Vertical Return with Extended
Chassis

SIZE
030
035
040
050
055
060
070
075
090
100
030
035
040
050
055
060
070
SIZE
075
090
100
075
090
100
SIZE
075
090
100
075
090
100

1
2009
2067
1992
2086
2350
2361
3159
3398
3282
3272
1872
1919
1899
1992
2467
2476
2683

CORNER WEIGHTS (lb)


2
3
1003
1002
1019
1018
1365
1363
1378
1377
2043
2040
2060
2057
1993
1556
2676
2089
2966
2453
2987
2470
1290
1288
1318
1316
1608
1606
1623
1620
2201
2198
2219
2216
2183
2180

4
2006
2064
1989
2084
2347
2357
2467
2653
2714
2706
1869
1916
1896
1990
2464
2473
2679

1
3290
3166
3163
3430
3306
3299

CORNER WEIGHTS (lb)


2
3
3405
2658
3688
3049
3702
3061
3573
2790
3849
3182
3867
3198

4
2568
2618
2615
2678
2734
2728

1
4006
3857
3854
6709
6308
6441

CORNER WEIGHTS (lb)


2
3
3350
2615
3641
3010
3655
3023
956
746
1491
1233
1370
1133

4
3128
3189
3187
5238
5216
5326

TOTAL
(lb)
6,019
6,169
6,710
6,925
8,780
8,835
9,175
10,815
11,415
11,435
6,319
6,469
7,010
7,225
9,330
9,385
9,725
TOTAL
(lb)
11,921
12,521
12,541
12,471
13,071
13,091
TOTAL
(lb)
13,099
13,697
13,719
13,649
14,247
14,269

A
in.
175 1/2
176 1/8
202 3/4
205 7/8
226
225 5/8
264 3/4
264 5/8
272 7/8
271 5/8
166 7/8
167 1/8
195 1/4
198 7/8
245 1/8
244 5/8
260 3/4

B
in.
45 7/8
45 7/8
45 7/8
45 7/8
45 7/8
45 7/8
40 1/4
40 1/4
41 1/2
41 1/2
45 7/8
45 7/8
45 7/8
45 7/8
45 7/8
45 7/8
45 7/8

A
in.
220 1/8
228 3/8
227 3/4
231 3/4
240 1/8
239 1/8

B
in.
40 1/4
41 1/2
41 1/2
40 1/4
41 1/2
41 1/2

A
in.
287 1/8
295 1/8
294 3/8
483 1/2
484 3/8
493 7/8

B
in.
40 1/4
41 1/2
41 1/2
40 1/4
41 1/2
41 1/2

LEGEND
PE Power Exhaust
NOTE: The weight distribution and center of gravity information include the impact of an economizer, the largest indoor fan motor, and a VFD (variable frequency
drive). On units with a return fan or high-capacity power exhaust, the largest motors and VFD are also included. These weights do not include the impact of other
factory-installed options such as barometric relief, power exhaust, high-capacity indoor coil, hot water coil, or indoor fan.

26

OPERATING WEIGHTS OF OPTIONS AND ACCESSORIES (lb)


OPTION OR ACCESSORY
Electric Heat*
Condenser Section Roof Curb
Economizer
Power Exhaust (PE)
Barometric Relief
Double Wall Construction
Roof Curb
48P Standard Length
48P Extended Length
48P with High Capacity PE
50P Standard Length
50P with Discharge Plenum
50P Extended Length
50P Extended Length with Discharge Plenum
50P with High Capacity PE
High-Efficiency Filters
Bag Filters, Cartridge Filters
Hail Guard
Variable Frequency Drive
7.5 hp
10 hp
15 hp
20 hp
25 hp
30 hp
40 hp
50 hp
60 hp
75 hp
High-Capacity Evaporator Coil
Airfoil Fan
Humidi-MiZer Adaptive Dehumidification System
Hot Water Coil*

030,035
140

300
710
200
700

040,050
140

300
710
200
800

455
545

390
455
545
545

20
35
120

495
545

480
495
545
545

20
35
150

20
20
35
35
53
53
53
53
53
152
150

72
150

20
20
35
35
53
53
53
53
53
152
300

72
150

48/50P UNIT SIZE


060
070
140
140
540
625
530
530
710
710
200
200
900
900

075
250
625
530
710
200
900

090
250
625
530
710
200
900

100
250
625
530
710
200
900

605
1200

560
605
545
1200

20
40
145

605
1200

560
605
545
1200

20
40
145

605

560
605
545

20
40
210

605

700
605
605

700
20

210

605

700
605
605

700
20

210

605

700
605
605

700
20

210

20
20
35
35
53
53
53
53
53
152
300

72
180

20
20
35
35
53
53
53
53
53
152
300

72
180

20
20
35
35
53
53
53
53
53
152
300

72
180

20
20
35
35
53
53
53
53
53
152
300
350
72
180

20
20
35
35
53
53
53
53
53
152
300
350
92
180

20
20
35
35
53
53
53
53
53
152
300
350
92
180

055
140
540
530
710
200
900

*50 series units only.


Includes hood.

SUPPLY FAN DRIVE DATA


HP
Sizes 030-050
7.5

SHAFT
DIA (in.)

SPEED
(rpm)

MOTOR
SHEAVE

MOTOR
PITCH DIA. (in.)

WHEEL
SHEAVE

WHEEL
PITCH DIA. (in.)

QUANTITY
...BELT

13/8

438

2BK36

3.4

2B5V136

13.7

2...BX60

10

13/8

549

2B5V42

4.3

2B5V136

13.7

2...5VX630

15

15/8

626

2B5V48

4.9

2B5V136

13.7

2...5VX630

20

15/8

703

2B5V54

5.5

2B5V136

13.7

2...5VX630

25

17/8

830

2B5V64

6.5

2B5V136

13.7

2...5VX650

30*

17/8

910

3B5V64

6.5

3B5V124

12.5

3...5VX630

15

15/8

575

2B5V44

4.5

2B5V136

13.7

20

15/8

651

2B5V50

5.1

2B5V136

13.7

25

17/8

703

2B5V54

5.5

2B5V136

13.7

30

17/8

711

2B5V62

5.9

2B5V154

15.5

40

21/8

740

3B5V66

6.7

3B5V160

16.1

2...5VX1230
2...5VX1120**
2...5VX1230
2...5XV1150**
2...5VX1230
2...5VX1150**
2...5VX1230
2...5VX1180**
3...5VX1250
3...5VX1180**

Sizes 055-070

Sizes 075-100 (Forward Curved Fan)


30
17/8

501

3B5V52

5.33

B5V184

18.5

3...5VX1320

40

21/8

539

4B5V56

5.74

B5V184

18.5

4...5VX1320

50

21/8

615

4B5V64

6.54

B5V184

18.5

4...5VX1320

60

23/8

672

4B5V70

7.14

B5V184

18.5

4...5VX1320

Sizes 075-100 (Airfoil Fan)


30
17/8

1353

2B5V74

7.5

2Q5V97

9.7

2...5VX1150

40

21/8

1493

2B5V86

8.7

2Q5V103

10.2

2...5VX1180

50

21/8

1593

3B5V80

8.1

3R5V90

8.9

3...5VX1150

60

23/8

1711

3B5V86

8.7

3R5V90

8.9

3...5VX1150

75

23/8

1799

3B5V110

11.1

3R5V109

10.8

3...5VX1230

*Sizes 040,050 only.


Horizontal discharge units (50 Series only).
**Vertical discharge and extended plenum units.
NOTE: Part numbers are Browning Manufacturing Corp. reference.

27

Physical data (cont)


POWER EXHAUST FAN DRIVE DATA (Two Drive Sets Per Unit)
MOTOR
TOTAL MOTOR
SHAFT
HP
QTY...HP DIAMETER
(in.)
Sizes 030-050
6
2...3
10
2...5
15
2...7.5
20
2...10
Sizes 055-100
10
2...5
15
2...7.5
20
2...10

FAN
SPEED
RPM

MOTOR SHEAVE
Pitch
Part
Diameter
Number
(in.)

BLOWER SHEAVE
Pitch
Part
Diameter
Number
(in.)

48/50P2,P3 UNITS
CENTER
BELTS
DISTANCE
QTY...P/N
RANGE (in.)

48/50P4,P5 UNITS
CENTER
BELTS
DISTANCE
QTY...P/N
RANGE (in.)

1 1 /8
1 1 /8
13/8
13/8

656/500
785/621
882/717
1000/854

1VP44L
1VP50L
1VP65
1VP75

4.1-3.1
4.7-3.7
6.0-4.8
7.0-5.8

BK115
BK110
BK130
BK130

11
10.4
12
12

1...BX71
1...BX71
1...BX77
1...BX79

23.62-26.50
23.62-26.50
23.62-26.50
23.62-26.50

1...BX46
1...BX46
1...BX53
1...BX53

11.40-13.26
11.16-13.05
11.40-13.26
11.04-12.95

1 1 /8
13/8
13/8

740
820
920

2P3V45
2P3V50
2P3V56

4.5
5.0
5.6

2Q3V106
2Q3V106
2Q3V106

10.6
10.6
10.6

2...3VX71
2...3VX71
2...3VX75

22.71-26.38
22.71-26.38
22.71-26.38

2...3VX50
2...3VX50
2...3VX50

10.91-13.30
10.78-13.20
10.78-13.20

NOTE: Part numbers are Browning Manufacturing Corp. reference.

HIGH-CAPACITY POWER EXHAUST FAN DRIVE DATA (Two Drive Sets Per Unit)
(Size 075-100 Units Only)
TOTAL
HP

MOTOR
QTY...HP

MOTOR
SHAFT
DIAMETER
(in.)

FAN
SPEED
RPM

20
30
40
50
60

2...10
2...15
2...20
2...25
2...30

1.375
1.625
1.625
1.875
1.875

714
841
928
1020
1094

MOTOR SHEAVE
Pitch
Part
Diameter
Number
(in.)
2B5V48
4.8
2B5V58
5.8
2B5V58
5.9
2B5V64
6.5
2B5V68
6.9

BLOWER SHEAVE
Pitch
Part
Diameter
Number
(in.)
2B5V124
12.4
2B5V124
12.4
2B5V110
11.1
2B5V110
11.1
2B5V110
11.1

BELTS
QTY...P/N

CENTER
DISTANCE
RANGE (in.)

2...BX93
2...BX93
2...5VX950
2...5VX950
2...5VX950

32.8 to 36.7
32.6 to 36.5
32.6 to 36.5
32.5 to 36.3
32.5 to 36.3

OPTIONAL RETURN/EXHAUST FAN DRIVE DATA (One Drive Set Per Unit)
(Size 075-100 Units Only)
TOTAL
HP

MOTOR
QTY...HP

MOTOR
SHAFT
DIAMETER
(in.)

FAN
SPEED
RPM

20
25
30
40

1...20
1...25
1...30
1...40

1.625
1.875
1.875
2.125

1104
1209
1271
1396

28

MOTOR SHEAVE
Pitch
Diameter
(in.)
3B5V52
5.3
3B5V66
6.7
3B5V60
6.1
3B5V66
6.7

Part
Number

BLOWER SHEAVE
Pitch
Part
Diameter
Number
(in.)
3R5V85
8.5
3R5V97
9.8
3R5V85
8.5
3R5V85
8.5

BELTS
QTY...P/N

CENTER
DISTANCE
RANGE (in.)

3...5VX1000
3...5VX1060
3...5VX1030
3...5VX1060

38.1 to 41.0
38.9 to 41.8
38.9 to 41.8
39.9 to 42.8

Options and accessories


ITEM
GAS HEAT (48P units only)
Low Gas Heat Aluminized Heat Exchanger
High Gas Heat Aluminized Heat Exchanger
Low Gas Heat Stainless Steel Heat Exchanger
High Gas Heat Stainless Steel Heat Exchanger
Staged Low Gas Heat Stainless Steel Heat Exchanger
Staged High Gas Heat Stainless Steel Heat Exchanger
Modulating Low Gas Heat Stainless Steel Heat Exchanger
Modulating High Gas Heat Stainless Steel Heat Exchanger
ELECTRIC HEAT (50P units only)
Staged Electric Heat
SCR Controlled Electric Heat
HYDRONIC HEAT (50P units only)
2-Row Hot Water Coil
Modulating Hot Water Control Valve
Steam Coil
INDOOR AIR QUALITY
Double Wall Construction in Airstream
AgION Double Wall Construction in Airstream
Outdoor Air cfm Station
MERV 7 Pleated, 2-in. Filter Package
MERV 11 Pleated, 2-in. Filter Package (sizes 075-100 only)
MERV 14 Bag Filter Package with Integral 2-in. Prefilters (sizes 030-070 only)
12 in. Cartridge Filter with Integral 2-in. Thick Prefilters (sizes 030-070 only)
MERV 8 2-in. Thick Filter Kit
MERV 8 4-in. Thick Filter Kit
MERV 11 4-in. Thick Filter Kit
MERV 13 4-in. Thick Filter Kit
MERV 14 4-in. Thick Filter Kit
MERV 14, 12-in. Cartridge Filter Kit (sizes 030-070 only)
UVC Lamps (with Door Interlocks and Disconnect Switch)
ECONOMIZER
Manual Outside-Air, Self-Closing Damper
Enthalpy Control Economizer
Ultra Low Leak Economizer
Outdoor or Return Humidity Sensor (Enthalpy)
EXHAUST AIR CONTROL
Barometric Relief
Non-Modulating Power Exhaust
Modulating Power Exhaust with VFD
Modulating Power Exhaust with VFD and Bypass
High-Capacity Power Exhaust with VFD (sizes 075-100 only)
Return Fan with VFD (sizes 075-100 only)
CONDENSER AND EVAPORATOR COIL
Al/Al E-Coat Novation MCHX Condenser Coil
High-Capacity Evaporator Coil
Pre-Coat Al/Cu Evaporator Coil
E-Coat Al/Cu Evaporator Coil
Cu/Cu Evaporator Coil
Hot Gas Bypass (Circuit A)
Condenser Coil Hail Guard Assembly (sizes 030-060 only)
Humidi-MiZer Adaptive Dehumidification System
POWER CIRCUIT
GFI Convenience Outlet (Powered on Load-Side)
GFI Convenience Outlet (Non-Powered)
Power Terminal Block
Non-Fused Disconnect
Disconnect with UL489 Circuit Breaker (HACR)
Fused Disconnect
Phase Protection Monitor
65KA Short Circuit Current Rating (208,230,460 volt)
25KA Short Circuit Current Rating (575 volt only)
Al
Cu
ETO
GFI
IFM
MCHX
SCR
UVC
VFD

LEGEND
Aluminum
Copper
Engineered-To-Order
Ground Fault Interrrupt
Indoor Fan Motor
Microchannel Heat Exchanger
Silicon Controlled Rectifier
Ultraviolet
Variable Frequency Drive

OPTION*

ACCESSORY

SPECIAL ORDER**

X
X
X
X
X
X
X
X
X
X

X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
*Factory installed.
Field installed.
**A special order is offered to meet specific customer requirements. Quotations
for special order options can be requested via the Carrier ETO process. Lead
times and prices vary with the option.
Standard 2-in. filter track may be field converted to accept 4-in. filters.

29

Options and accessories (cont)


ITEM
CONTROLS
Controls Expansion Module (CEM)
BACnet Communication
System Pilot Interface
Touch Pilot Interface
Navigator Display
Return Air CO2 Sensor
CO2 Space Sensor
Return Air Smoke Detector
Return and Supply Air Smoke Detectors Installed
Filter Switch
Fan Status Switch (requires CEM)
T-55 Space Temperature Sensor with Override
T-56 Space Temperature Sensor with Override and Set Point Adjustment
Space Temperature Sensor with CO2 Override
Space Temperature Sensor with CO2 Override and Set Point Adjustment
MODBUS Carrier Translator
LonWorks Carrier Translator
INDOOR FAN AND MOTOR
Bypass on IFM VFD
Airfoil Fan (sizes 075-100 only)
PACKAGING
Domestic
Export
MISCELLANEOUS
Digital Compressor
Refrigeration Service Valves
Replacable Core Filter Drier
Extended Chassis
14-in. Roof Curb
Condenser Section Roof Curb (sizes 070-100 only)
Security Grille (sizes 070-100 only)
Low Ambient Control
Extended Lube Lines
Access Door Retainers
Horizontal Supply / Vertical Return
Vertical Supply / Horizontal Return
Low Outdoor Sound
Low Compressor Sound

Chassis arrangements (48 Series units)


Standard length chassis with vertical discharge
The standard, compact, vertical discharge arrangement is
provided with a bottom, return-air opening, straightthrough air path, and horizontal discharge into the heating
section with bottom supply air outlet. Ductwork is attached
to accessory roof curb. These units are available with
factory-installed optional power exhaust or barometric relief
packages in conjunction with factory-installed optional
economizers.

OPTION*

ACCESSORY

X
X

SPECIAL ORDER**

X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X

X
X
X
X
X

X
X

Vertical discharge with optional return fan This


vertical discharge arrangement adds a factory-installed
return fan and VFD. Return air enters through the bottom
opening upstream of the return fan and follows a straightthrough path to the supply fan and into the heating section,
where it exits through the bottom supply air outlet. Ductwork is attached to the accessory roof curb.
OPTIONAL RETURN FAN

STANDARD CHASSIS

a48-8427
a48-8426

30

Extended length chassis with vertical discharge


The extended length chassis arrangement provides an additional 25-in. of unit length located between the evaporator
coil section and the supply fan sled. This compartment is
used for field-installation of an auxiliary coil. The auxiliary
coil can be a hydronic heating coil, a steam heating coil, or
a refrigeration heat reclaim coil. The extended length compartment includes tracks to accept the field-supplied and
installed auxiliary coil.

Vertical discharge with optional return fan This


vertical discharge arrangement adds a factory-installed
return fan with VFD and extended rear plenum. Return air
enters unit through bottom opening upstream of the return
fan and follows a straight-through path to the supply fan
and into the extended plenum section, where it exits unit
through bottom supply air outlet. Ductwork is attached to
accessory roof curb. Return air exhaust outlet is on the end
of the chassis. Factory-installed optional electric heat is
available on these units.

EXTENDED LENGTH CHASSIS


OPTIONAL RETURN FAN

COIL
COMPARTMENT

a48-8428

Vertical discharge with optional high-capacity modulating power exhaust system This vertical discharge arrangement adds a factory-installed extended rear
plenum to house the integrated economizer and highcapacity modulating power exhaust systems (standard features on these models). Return air enters unit through bottom opening upstream of the power exhaust system and
follows a straight-through path to the supply fan and into
the heating section, where it exits unit through bottom supply air outlet. Ductwork is attached to accessory roof curb.
OPTIONAL HIGH-CAPACITY POWER EXHAUST

Standard length chassis with vertical discharge and


discharge plenum The standard, vertical discharge
arrangement is provided with a bottom, return-air opening, straight-through air path. The supply fan is arranged
for horizontal outlet into the discharge plenum area. Supply air exits from the discharge plenum area downward
through the bottom of the unit. Ductwork is attached to
accessory roof curb. These units are available with factoryinstalled optional power exhaust or barometric relief packages in conjunction with factory-installed optional economizers.
STANDARD CHASSIS WITH DISCHARGE PLENUM
DISCHARGE
PLENUM

Chassis arrangements (50 Series units)


Standard length chassis with vertical discharge
The standard, compact, vertical discharge arrangement is
provided with a bottom return-air opening, straight-through
air path, and direct, vertical-discharge, supply fan for bottom supply air. Ductwork is attached to accessory roof
curb. These units are available with factory-installed
optional electric heat. Factory-installed optional power
exhaust is available in conjunction with factory-installed
optional economizer.
STANDARD CHASSIS

Standard length chassis with horizontal discharge


The standard, compact, horizontal discharge arrangement is provided with a return-air end opening, straightthrough air path, and supply-air discharge on the unit left
hand side. Ductwork is attached to flanges on the outer
cabinet. Electric heaters are not available on size 030-070
units. Factory-installed optional economizers are available.
Factory-installed power exhaust is available.
STANDARD CHASSIS WITH
HORIZONTAL DISCHARGE

31

Options and accessories (cont)


Vertical discharge with optional high-capacity modulating power exhaust systems This vertical discharge arrangement adds a factory-installed extended rear
plenum to house the integrated economizer and highcapacity modulating power exhaust systems (standard features on these models). Return air enters unit through bottom opening upstream of the power exhaust system and
follows a straight-through path to the supply fan and into
the extended plenum section, where it exits unit through
bottom supply air outlet. Ductwork is attached to accessory
roof curb. Economizer inlets are on both sides of the unit;
power exhaust outlet is on the end of the chassis. Factoryinstalled optional electric heat is available on these units.

Extended length chassis with vertical discharge


The extended length, vertical discharge arrangement is
provided with a bottom, return-air opening, straightthrough air path, and direct, vertical-discharge, supply fan
for bottom supply air. Ductwork is attached to accessory
roof curb. These units are available with factory-installed
optional power exhaust or barometric relief packages in
conjunction with factory-installed optional economizers.
EXTENDED LENGTH CHASSIS

OPTIONAL HIGH-CAPACITY POWER EXHAUST


COIL
COMPARTMENT

Horizontal discharge with optional high-capacity


modulating power exhaust systems This horizontal
discharge arrangement adds a factory-installed extended
rear plenum to house the integrated economizer and highcapacity modulating power exhaust systems (standard features on these models). Return air enters the chassis
through dual openings on the left-hand side of unit. The
supply fan discharges horizontally into the extended plenum section with unit supply air outlet on the left-hand
side. Ductwork is attached to flanges on the outer cabinet.
Economizer inlets are on both sides of the unit; power
exhaust outlet is on the end of the chassis.

Extended length chassis with vertical discharge


and discharge plenum The extended length vertical
discharge arrangement is provided with a bottom, returnair opening, straight-through air path. The supply fan is
arranged for horizontal outlet into the extended plenum
area. Supply air exits from the extended plenum area
downward through the bottom of the unit. Ductwork is
attached to accessory roof curb. These units are available
with factory-installed optional power exhaust or barometric
relief packages in conjunction with factory-installed
optional economizers. Electric heaters are not available on
these units.
EXTENDED LENGTH CHASSIS
WITH DISCHARGE PLENUM
DISCHARGE
PLENUM

OPTIONAL HIGH-CAPACITY POWER EXHAUST

COIL
COMPARTMENT

Horizontal discharge with optional return fan and


modulating exhaust damper This horizontal discharge arrangement adds a factory-installed return fan with
VFD and extended rear plenum. Return air enters the
chassis through the bottom opening upstream of the return
fan. The supply fan discharges horizontally into the
extended plenum section with unit supply air outlet on the
left-hand side. Ductwork is attached to flanges on the outer
cabinet. Return air exhaust outlet is on the end of the
chassis.

Extended length chassis with horizontal discharge


The extended length horizontal discharge arrangement
is provided with a return-air end opening, straight-through
air path, and supply-air discharge on the unit left hand
side. Ductwork is attached to flanges on the outer cabinet.
Electric heaters and barometric relief packages are not
available on these units. Factory-installed optional economizers are available. Factory-installed optional power
exhaust is available.

OPTIONAL RETURN FAN

EXTENDED LENGTH CHASSIS

COIL
COMPARTMENT

32

48P4,P5030,035 UNIT

This section details six examples of the P Series


large rooftop unit. To determine dimensions for the
appropriate unit for your application, refer to the
Applied Rooftop Builder software.

Base unit dimension examples

a48-8444

33

34
This section details six examples of the P Series
large rooftop unit. To determine dimensions for the
appropriate unit for your application, refer to the
Applied Rooftop Builder software.

50P2,P3030,035 UNITS (UNIT WITH OPTIONAL EXTENDED PLENUM SHOWN)

Base unit dimension examples (cont)

a50-8376

a48-8635

35

48P2,P3055,060 UNITS

This section details six examples of the P Series


large rooftop unit. To determine dimensions for the
appropriate unit for your application, refer to the
Applied Rooftop Builder software.

50P2,P3055,060 UNITS

This section details six examples of the P Series


large rooftop unit. To determine dimensions for the
appropriate unit for your application, refer to the
Applied Rooftop Builder software.

Base unit dimension examples (cont)

a50-8714

36

a48-8636

37

48P4,P5075-100 UNITS

This section details six examples of the P Series


large rooftop unit. To determine dimensions for the
appropriate unit for your application, refer to the
Applied Rooftop Builder software.

38
This section details six examples of the P Series
large rooftop unit. To determine dimensions for the
appropriate unit for your application, refer to the
Applied Rooftop Builder software.

50P2,P3075-100 UNITS (UNITS WITH OPTIONAL HIGH-CAPACITY POWER EXHAUST SHOWN)

Base unit dimension examples (cont)

a48-8432

Accessory dimensions

ROOF CURB SIZES 030-050

a48-8433

39

Accessory dimensions (cont)

ROOF CURB SIZES 055,060

a48-8434

40

ROOF CURB SIZES 070-100

a48-8435

41

CONDENSER SECTION ROOF CURB SIZES 070 AND 075

Accessory dimensions (cont)


a48-8436

42

CONDENSER SECTION ROOF CURB SIZES 090 AND 100

a48-8437

43

Selection procedure
I Determine cooling and heating loads at design
conditions.
Given:
Required Gross Cooling
Capacity (TC). . . . . . . . . . . . . . . . .950,000 Btuh
Sensible Gross Heat Capacity (SHC) . .775,000 Btuh
Required Heating Capacity . . . . . . . . .500,000 Btuh
Condenser Entering-Air Temperature db . . . . . .95 F
Indoor Air Temperature . . . . . . . 82 F edb, 67 F ewb
Evaporator Air Quantity . . . . . . . . . . . . 31,500 Cfm
External Static Pressure . . . . . . . . . . . . . .3.0 in. wg
Electrical Characteristics (V-Ph-Hz) . . . . . . 460-3-60
Integrated economizer required.
Options: VFD on supply fan, 65% filters, premium
efficiency motor, integrated economizer, power
exhaust, airfoil fan, vertical duct configuration.
II Select the rooftop unit based on required
cooling capacity.
Enter cooling capacity table on page 91 for size 090
(standard capacity coil) at condenser entering temperature 95 F, evaporator air quantity of 31,500 cfm,
and an indoor wet bulb temperature of 67 F.
The unit will provide a total gross cooling capacity of
1,011,000 Btuh and an SHC of 750,000 Btuh.
Since these values were not at 80 F edb, calculate an
SHC correction (at 82 F edb) based on the notes following the Cooling Capacity tables. Calculate a corrected SHC of 812,400 Btuh.
Unit meets design conditions for TC and SHC.
NOTE: Unit ratings are gross capacities and do not
include the effect of supply-fan motor heat. To calculate net capacities see Step V.
III Select net heating capacity of unit to meet
design condition requirements.
Enter the Gas Heating Capacities table on page 7.
The 48P2090 unit (low heat) will provide 526,000
Btuh of heating with an input of 650,000 Btuh.
IV Determine fan speed and power requirements at
design conditions.
Before entering the Fan Performance tables, calculate
the selection static pressure required based on unit

44

components. Tabulated fan performance includes


2-in. filters and wet evaporator coils. From the given
and the Component Pressure Drops table on
page 126 find:
Design external static pressure
3.00 in. wg
Low Gas Heat
0.70 in. wg
Economizer
0.28 in. wg
65% Filters
0.22 in. wg
Modulating PE
0.25 in. wg
Total Selection Static Pressure
4.45 in. wg
Enter the Fan Performance table on page 120 for
48P2090 with airfoil fan at 4.45 in. wg at 31,500
cfm. The 50 Hp motor will provide the required ESP
at 1548 rpm and 44.53 Bhp.
V Determine net capacities (if required).
Cooling capacities are gross capacities and do not include supply-fan motor (IFM) heat.
Use the Bhp determined in Step IV to find IFM watts:
Watts = Bhp x 746/(Motor Efficiency/100)
= 44.53 x 746/(94.5/100)
= 35,153
Convert Watts to Btuh:
Btuh = Watts x 3.412 Btuh/Watt
= 35,153 x 3.412
= 119,941 Btuh (IFM Heat)
Net Capacity = Gross Capacity IFM Heat
= 1,011,000 119,941
= 891,059 Btuh
Net Sensible Capacity = Gross SHC IFM Heat
= 812,400 119,941
= 692,459 Btuh
VI Select the unit that corresponds to power source
available.
The model number nomenclature on page 6 shows
that the 460-3-60 unit is available.

Performance data
Humidi-MiZer performance data
The following pages of Performance Data include performance tables for Humidi-MiZer equipped units. The tables
include capacity in normal cooling, subcooling mode and
hot gas reheat mode.
For hot gas reheat performance, the ambient outdoor air
and return air temperature ranges are different from the
ranges listed for normal design cooling and subcooling
rooftop operation. This is to provide appropriate performance data for those conditions when the rooftop unit
would most likely respond to provide all latent capacity removal from the space.
All performance data are provided in terms of gross capacities. Combined, the subcooling and reheat tables provide the endpoints of performance potential for each unit

at specific conditions. In reality, the P Series Humidi-MiZer


equipped unit will modulate refrigerant bypass flow to ensure that it meets the supply air set point while maintaining
low evaporator temperatures needed for maximum moisture removal. This means that the unit sensible capacity
varies between the two tables, depending on the load in
the space.
The chart below graphically demonstrates this capability.
Note that latent capacity stays fairly constant between Subcooling mode and Hot Gas Reheat mode, while sensible
capacity varies almost infinitely between the two endpoints
of the table. This clearly demonstrates how accurate space
temperature and humidity control can be maintained
through the P Series innovative modulating refrigerant flow
Humidi-MiZer application.

Variable Sensible Heat Ratio (SHR) Example


80 F dB/67 F wB Ent Air, 95 F Outdoor, Constant Volume CFM

60.0

50.0

In this example, unit SHR can range


from 0.00 to 0.60 between Reheat and
Subcooling modes depending on
space requirements. Refrigerant flow
to the Humidi-MiZer coil will be
modulated to meet the SHR required.
In normal cooling mode, the unit
would operate at 0.66 SHR.

0.66 SHR

0.60 SHR

Ca
apacity (Tons)

40.0

Sensible

30.0

Latent

20.0

10.0
0.00 SHR
0.0
100% Reheat

100% Subcool

Normal

45

Performance data (cont)


COOLING CAPACITIES
48/50P2,P3,P4,P5030 (30 TON) STANDARD CAPACITY COIL STANDARD MODE
Evaporator Air Quantity Cfm
Temp (F)
6,000
7,500
9,000
Air Entering
Condenser
Evaporator Air Ewb (F)
(Edb)
75
72
67
62
57
75
72
67
62
57
75
72
67
TC
378 362 334 308 282 399 379 351 325 297
412 392 363
SHC
155 167 204 236 265 159 183 224 262 292
166 195 241
75
22.5 22.1 21.3 20.8 20.5 23.0 22.5 21.7 21.2 20.7 23.4 22.8 22.1
kW
BF
0.00 0.00 0.22 0.16 0.14 0.00 0.00 0.19 0.16 0.19 0.00 0.27 0.20
TC
367 353 326 300 273 384 369 342 316 290
396 380 353
150 165 201 231 259 155 180 220 257 281
162 191 236
SHC
85
kW
24.7 24.4 23.7 23.4 23.2 25.2 24.8 24.1 23.7 23.1 25.6 25.1 24.4
BF
0.00 0.00 0.21 0.15 0.14 0.00 0.16 0.18 0.16 0.23 0.00 0.25 0.20
TC
357 343 316 289 264 373 357 331 304 281
383 368 341
SHC
146 162 196 226 253 150 176 215 252 272
159 187 232
95
kW
27.4 27.1 26.6 26.4 26.1 27.9 27.5 27.0 26.6 26.1 28.2 27.8 27.3
0.00 0.00 0.19 0.15 0.14 0.00 0.28 0.18 0.16 0.26 0.00 0.24 0.19
BF
TC
344 330 304 277 251 360 344 318 291 268
369 354 327
SHC
141 158 191 220 244 145 171 210 246 268
154 182 226
105
30.5 30.3 30.0 29.8 30.2 31.0 30.7 30.3 30.0 29.9 31.2 31.0 30.6
kW
BF
0.00 0.00 0.17 0.14 0.16 0.00 0.25 0.17 0.15 0.23 0.18 0.22 0.19
TC
330 315 289 263 237 344 328 302 276 256
352 337 310
SHC
135 153 185 214 234 141 166 203 239 256
149 177 219
115
kW
34.0 33.9 33.9 34.2 34.6 34.4 34.3 34.1 34.3 34.6 34.7 34.6 34.3
BF
0.00 0.00 0.16 0.14 0.18 0.00 0.22 0.17 0.15 0.27 0.29 0.21 0.18

62
336
285
21.4
0.18
327
281
23.9
0.18
315
275
26.9
0.17
301
269
30.2
0.17
285
261
34.4
0.17

57
312
312
21.0
0.26
305
305
23.6
0.27
295
295
26.6
0.30
284
284
30.1
0.32
272
272
34.5
0.35

48/50P2,P3,P4,P5030 (30 TON) STANDARD CAPACITY COIL STANDARD MODE (cont)


Evaporator Air Quantity Cfm
Temp (F)
12,000
13,500
15,000
Air Entering
Condenser
Evaporator Air Ewb (F)
(Edb)
75
72
67
62
57
75
72
67
62
57
75
72
67
TC
428 408 378 352 339 434 414 383 357 349 439 418 388
SHC
182 216 272 326 339 189 226 286 341 349 195 235 300
75
kW
23.8 23.3 22.5 21.8 21.5 24.0 23.4 22.6 21.9 21.8 24.1 23.6 22.7
BF
0.33 0.25 0.22 0.22 0.39 0.31 0.25 0.24 0.25 0.45 0.30 0.26 0.25
TC
411 395 368 341 330 417 400 373 346 340 422 404 376
SHC
177 212 268 321 330 183 221 282 334 340 190 230 296
85
kW
26.0 25.5 24.8 24.3 24.0 26.2 25.7 25.0 24.4 24.2 26.3 25.8 25.1
BF
0.30 0.24 0.22 0.22 0.41 0.29 0.25 0.23 0.26 0.46 0.29 0.25 0.25
TC
398 382 355 328 320 404 387 359 332 330 408 391 363
SHC
173 207 263 313 320 179 217 277 327 330 185 226 291
95
kW
28.6 28.2 27.6 27.2 27.0 28.8 28.3 27.7 27.3 27.2 28.9 28.5 27.8
BF
0.29 0.23 0.22 0.23 0.43 0.28 0.24 0.23 0.26 0.48 0.28 0.25 0.24
TC
383 367 340 313 308 388 371 344 320 317 392 375 347
SHC
168 202 257 303 308 175 212 271 309 317 180 221 285
105
kW
31.7 31.4 30.9 30.5 30.4 31.9 31.5 31.0 30.4 30.6 32.0 31.6 31.0
BF
0.27 0.23 0.22 0.24 0.45 0.26 0.24 0.23 0.32 0.50 0.27 0.25 0.24
TC
365 349 322 296 295 369 353 326 303 303 372 356 329
SHC
163 196 250 292 295 169 206 264 303 303 175 214 278
115
kW
35.3 35.0 34.5 34.4 34.5 35.4 35.1 34.6 34.5 34.5 35.5 35.2 34.6
BF
0.25 0.22 0.21 0.26 0.47 0.25 0.23 0.23 0.31 0.52 0.26 0.25 0.24

62
360
354
22.0
0.28
349
348
24.4
0.29
339
334
27.3
0.32
326
321
30.7
0.35
311
310
34.5
0.36

57
357
357
22.0
0.49
348
348
24.4
0.50
338
338
27.3
0.52
325
325
30.7
0.54
310
310
34.5
0.56

LEGEND
48/50P3,P5 units only.
BF Bypass Factor
kW
Compressor Motor Power Input
Edb Entering Dry Bulb
SHC Sensible Heat Cap. (1000 Btuh)
Ewb Entering Wet Bulb
TC
Total Cap. (1000 Btuh) Gross
NOTES:
1. Direct interpolation is permissible. Do not extrapolate.
2. The following formulas may be used:
sensible capacity (Btuh)
tldb = tedb
1.10 x cfm
tlwb =
hlwb =

Wet-bulb temperature corresponding to enthalpy of air


leaving evaporator coil (hlwb).
hewb

total capacity (Btuh)


4.5 x cfm

Where: hewb = Enthalpy of air entering evaporator coil.

46

10,500
75
421
175
23.6
0.00
404
170
25.8
0.36
391
166
28.4
0.31
377
162
31.5
0.28
360
156
35.1
0.26

72
401
206
23.1
0.25
389
202
25.3
0.24
376
198
28.0
0.23
361
193
31.2
0.22
344
187
34.8
0.21

67
372
256
22.3
0.21
361
252
24.7
0.21
349
248
27.5
0.21
334
242
30.7
0.20
317
235
34.4
0.20

62
345
307
21.6
0.19
335
303
24.1
0.19
322
296
27.1
0.20
308
288
30.5
0.20
291
279
34.5
0.21

57
327
327
21.3
0.33
319
319
23.8
0.35
309
309
26.8
0.37
297
297
30.2
0.39
285
285
34.4
0.42

3. SHC is based on 80 F edb temperature of air entering evaporator


coil.
Below 80 F edb, subtract (corr factor x cfm) from SHC.
Above 80 F edb, add (corr factor x cfm) to SHC.

BF

79
81

.05
.10
.20

1.04
0.99
0.88

ENTERING AIR DRY-BULB TEMP (F)


78
77
76
75
under 75
82
83
84
85
over 85
Correction Factor
2.09
3.14
4.18
5.22
Use formula
1.98
2.97
3.96
4.95 shown below
1.76
2.64
3.52
4.40

Interpolation is permissible.
Correction Factor = 1.10 x (1 BF) x (edb 80).
4. Cooling capacities are gross and do not include deduction for indoor
fan motor heat.

COOLING CAPACITIES (cont)


48/50P2,P3,P4,P5030 (30 TON) STANDARD CAPACITY COIL SUBCOOLING MODE
Evaporator Air Quantity Cfm
Temp (F)
6,000
7,500
9,000
Air Entering
Condenser
Evaporator Air Ewb (F)
(Edb)
75
72
67
62
57
75
72
67
62
57
75
72
67
TC
341 322 293 266 243 361 340 309 282 260 375 353 321
SHC
97
118 151 185 218 104 128 168 209 244 112 138 184
75
23.7 23.2 22.4 21.8 21.3 24.3 23.7 22.9 22.2 21.6 24.8 24.2 23.2
kW
BF
0.00 0.03 0.07 0.08 0.09 0.03 0.07 0.09 0.10 0.15 0.05 0.10 0.12
TC
320 301 274 249 227 335 316 288 262 244 346 327 298
78
100 135 170 205
83
108 150 192 229
89
117 164
SHC
85
kW
25.8 25.3 24.5 24.0 23.5 26.4 25.8 25.0 24.3 23.8 26.8 26.2 25.3
BF
0.00 0.03 0.07 0.08 0.10 0.03 0.07 0.09 0.10 0.16 0.06 0.10 0.12
TC
297 280 254 231 212 310 293 266 242 227 319 301 274
SHC
60
82
119 155 193
62
88
131 175 213
66
95
144
95
kW
28.2 27.7 27.0 26.5 26.0 28.7 28.1 27.4 26.7 26.3 29.1 28.5 27.6
0.00 0.04 0.07 0.08 0.10 0.03 0.07 0.09 0.10 0.17 0.06 0.10 0.12
BF
274 258 234 212 198 284 268 244 222 211 291 275 250
TC
SHC
42
65
102 140 179
42
68
113 158 197
43
73
125
105
30.9 30.4 29.8 29.2 28.8 31.3 30.8 30.1 29.5 29.1 31.6 31.0 30.3
kW
BF
0.00 0.04 0.07 0.08 0.13 0.04 0.07 0.09 0.10 0.18 0.06 0.10 0.12
TC
250 236 214 194 183 257 243 221 201 194 262 247 225
SHC
23
47
86
125 164
21
49
95
142 181
20
52
105
115
kW
33.9 33.4 32.8 32.3 32.1 34.2 33.7 33.0 32.5 32.2 34.4 33.9 33.2
0.01 0.04 0.07 0.08 0.14 0.04 0.08 0.10 0.10 0.20 0.07 0.11 0.12
BF

62
293
231
22.5
0.12
271
213
24.6
0.12
250
195
27.0
0.12
229
177
29.7
0.13
207
159
32.7
0.13

57
273
266
21.9
0.21
256
249
24.1
0.22
238
231
26.6
0.23
220
214
29.3
0.24
201
196
32.4
0.25

48/50P2,P3,P4,P5030 (30 TON) STANDARD CAPACITY COIL SUBCOOLING MODE (cont)


Evaporator Air Quantity Cfm
Temp (F)
12,000
13,500
15,000
Air Entering
Condenser
Evaporator Air Ewb (F)
(Edb)
75
72
67
62
57
75
72
67
62
57
75
72
67
TC
395 372 337 308 294 401 378 343 314 304 309 411 385
SHC
127 159 216 271 294 132 169 231 287 304 309 142 179
75
kW
25.5 24.8 23.8 22.9 22.5 25.7 25.0 24.0 23.1 22.8 22.9 26.1 25.2
BF
0.12 0.15 0.15 0.18 0.33 0.15 0.16 0.17 0.21 0.39 0.40 0.17 0.18
TC
363 342 311 274 285 368 348 316 290 282 374 352 321
SHC
100 134 193 274 255 105 143 208 263 282 112 152 222
85
kW
27.4 26.7 25.8 24.6 24.9 27.6 27.0 26.0 25.1 24.9 27.9 27.1 26.1
BF
0.13 0.15 0.15 0.34 0.19 0.15 0.17 0.17 0.22 0.40 0.17 0.18 0.19
TC
331 313 285 262 253 336 318 289 268 261 340 321 292
SHC
74
110 171 230 253
79
119 185 241 261
84
126 198
95
kW
29.6 29.0 28.0 27.3 27.0 29.8 29.2 28.2 27.5 27.2 30.0 29.3 28.3
BF
0.13 0.15 0.15 0.19 0.35 0.15 0.17 0.17 0.23 0.41 0.17 0.18 0.19
TC
301 284 258 241 233 304 287 261 245 239 307 289 263
SHC
49
86
149 208 233
53
93
161 219 239
57
100 174
105
kW
32.0 31.4 30.6 30.0 29.7 32.2 31.6 30.7 30.1 29.9 32.4 31.7 30.8
BF
0.13 0.15 0.16 0.21 0.37 0.15 0.17 0.17 0.24 0.42 0.17 0.18 0.19
TC
268 253 231 218 211 271 255 233 222 216 273 257 234
SHC
24
62
127 186 211
26
68
139 197 216
29
74
150
115
kW
34.7 34.1 33.4 32.9 32.7 34.8 34.3 33.5 33.0 32.9 34.9 34.3 33.6
BF
0.13 0.15 0.16 0.22 0.38 0.15 0.17 0.17 0.26 0.43 0.17 0.19 0.19

62
348
246
24.1
0.19
296
276
25.3
0.26
272
253
27.6
0.27
249
230
30.2
0.28
224
207
33.1
0.29

57
319
299
23.2
0.25
290
290
25.1
0.45
267
267
27.5
0.45
244
244
30.1
0.46
221
221
33.0
0.48

LEGEND
48/50P3,P5 units only.
BF Bypass Factor
kW
Compressor Motor Power Input
Edb Entering Dry Bulb
SHC Sensible Heat Cap. (1000 Btuh)
Ewb Entering Wet Bulb
TC
Total Cap. (1000 Btuh) Gross
NOTES:
1. The SHC is based on 80 F edb temperature of air entering evaporator coil. For edb temperatures other than 80 F, adjust SHC by
multiplying the correction factor and the cfm and then adding or
subtracting the value from the SHC.

10,500
75
385
118
25.1
0.10
355
94
27.1
0.10
326
70
29.4
0.10
296
46
31.8
0.10
266
21
34.6
0.10

72
363
149
24.5
0.13
335
125
26.5
0.13
308
102
28.7
0.13
280
80
31.3
0.13
251
56
34.0
0.13

67
330
200
23.5
0.14
305
179
25.6
0.14
280
158
27.9
0.14
254
137
30.4
0.14
228
116
33.3
0.14

62
301
252
22.7
0.15
279
232
24.8
0.15
257
213
27.1
0.15
234
194
29.8
0.16
213
176
32.8
0.17

57
283
283
22.2
0.26
264
264
24.3
0.28
245
245
26.8
0.29
225
225
29.5
0.30
205
205
32.6
0.32

2. Interpolation is permissible.
3. Correction Factor = 1.10 x (1 BF) x (edb 80).
4. Cooling capacities are gross and do not include deduction for
indoor fan motor heat.
5. SHC values provided are in subcooling mode with the gas bypass
valve closed and reflect the maximum SHC in subcooling mode.
The P Series innovative modulating valve system can reduce SHC
as needed to meet the supply air set point requirement with minimal change in latent capacity. This will provide variable SHC to
meet the space load.

47

Performance data (cont)


COOLING CAPACITIES (cont)
48/50P2,P3,P4,P5030 (30 TON) STANDARD CAPACITY COIL HOT GAS REHEAT MODE
Air Entering Evaporator Ewb (F)
Temp (F)
75 Dry Bulb
75 Dry Bulb
Air Ent
62.5 Wet Bulb (50% RH)
65.3 Wet Bulb (60% RH)
Condenser
Air Entering Evaporator Cfm
(Edb)
6000
7500
9000
10,500
12,000
13,500
15,000
6000
7500
9000
10,500
12,000
TC
115
123
128
132
135
137
139
121
129
135
138
141
SHC
1
9
19
29
40
50
61
-25
-21
-16
-10
-3
80
kW
23.1
23.0
23.1
23.1
23.2
23.3
23.3
23.6
23.6
23.6
23.7
23.7
BF
0.07
0.10
0.12
0.14
0.16
0.17
0.19
0.06
0.09
0.11
0.13
0.15
TC
117
126
131
135
138
140
142
124
132
137
141
144
SHC
3
11
21
31
41
52
63
-24
-20
-14
-8
-1
75
kW
22.4
22.3
22.4
22.5
22.5
22.6
22.7
23.0
22.9
23.0
23.1
23.2
BF
0.07
0.10
0.12
0.14
0.16
0.17
0.19
0.06
0.09
0.11
0.13
0.15
TC
120
128
134
138
141
143
145
126
134
140
144
147
SHC
4
13
22
32
43
53
64
-23
-18
-13
-7
-0
70
kW
21.7
21.7
21.8
21.9
22.0
22.1
22.1
22.3
22.3
22.4
22.5
22.6
BF
0.07
0.10
0.12
0.14
0.16
0.17
0.19
0.06
0.09
0.11
0.13
0.15
TC
119
126
131
135
137
139
141
124
132
137
140
143
SHC
4
12
21
31
41
52
63
-23
-19
-14
-8
-1
60
kW
22.3
22.4
22.6
22.7
22.8
22.9
23.0
23.0
23.2
23.3
23.4
23.5
BF
0.07
0.10
0.12
0.14
0.16
0.17
0.19
0.06
0.09
0.11
0.13
0.15
TC
123
131
136
140
142
144
146
129
136
142
145
148
SHC
6
15
24
34
44
55
65
-21
-17
-12
-5
2
50
kW
21.1
21.3
21.4
21.6
21.7
21.9
22.0
21.9
22.0
22.2
22.3
22.4
BF
0.07
0.10
0.12
0.14
0.16
0.17
0.19
0.06
0.09
0.11
0.13
0.15
TC
127
135
140
144
147
150
152
132
141
146
151
154
SHC
9
17
26
36
47
57
68
-18
-15
-9
-3
5
40
kW
20.1
20.3
20.5
20.7
20.8
20.9
21.0
20.9
21.1
21.2
21.4
21.5
BF
0.07
0.10
0.12
0.14
0.15
0.17
0.19
0.06
0.09
0.11
0.13
0.15

13,500
143
5
23.8
0.17
146
6
23.2
0.17
149
7
22.7
0.17
145
6
23.6
0.17
150
9
22.6
0.17
157
12
21.7
0.17

15,000
145
12
23.9
0.19
148
14
23.3
0.19
151
15
22.8
0.19
146
14
23.7
0.19
152
17
22.7
0.19
159
20
21.8
0.19

48/50P2,P3,P4,P5030 (30 TON) STANDARD CAPACITY COIL HOT GAS REHEAT MODE (cont)
Air Entering Evaporator Ewb (F)
Temp (F)
75 Dry Bulb
75 Dry Bulb
Air Ent
68 Wet Bulb (70% RH)
70.5 Wet Bulb (80% RH)
Condenser
Air Entering Evaporator Cfm
(Edb)
6000
7500
9000
10,500
12,000
13,500
15,000
6000
7500
9000
10,500
12,000
TC
127
135
141
144
147
149
151
133
141
146
150
152
SHC
-52
-52
-50
-48
-44
-40
-36
-77
-81
-83
-83
-83
80
kW
24.3
24.2
24.2
24.3
24.4
24.5
24.5
24.9
24.9
24.9
25.0
25.0
BF
0.03
0.07
0.10
0.13
0.15
0.17
0.18
0.00
0.02
0.05
0.10
0.12
TC
130
138
143
147
150
152
154
135
143
149
153
156
SHC
-50
-50
-49
-46
-43
-39
-34
-76
-80
-81
-82
-81
75
kW
23.6
23.6
23.7
23.7
23.8
23.9
24.0
24.3
24.3
24.3
24.4
24.5
BF
0.03
0.07
0.10
0.13
0.15
0.17
0.18
0.00
0.02
0.05
0.09
0.12
TC
132
140
146
150
153
156
158
137
146
152
156
160
SHC
-49
-49
-48
-45
-41
-37
-32
-75
-78
-80
-80
-79
70
kW
23.0
23.0
23.1
23.2
23.3
23.4
23.4
23.8
23.7
23.8
23.8
23.9
BF
0.03
0.07
0.10
0.12
0.15
0.16
0.18
0.00
0.01
0.05
0.09
0.12
TC
130
137
142
146
148
150
152
135
142
147
151
154
SHC
-50
-50
-49
-46
-42
-38
-34
-76
-79
-81
-81
-81
60
kW
23.8
23.9
24.0
24.1
24.3
24.4
24.4
24.6
24.7
24.8
24.9
25.0
BF
0.03
0.07
0.10
0.13
0.15
0.17
0.18
0.00
0.02
0.05
0.10
0.13
TC
134
142
147
151
154
157
159
139
147
153
157
160
SHC
-47
-48
-46
-43
-40
-35
-30
-73
-77
-78
-78
-77
50
kW
22.7
22.8
22.9
23.1
23.2
23.3
23.4
23.5
23.5
23.7
23.8
23.9
BF
0.02
0.07
0.10
0.13
0.15
0.16
0.18
0.00
0.01
0.05
0.09
0.12
TC
138
147
153
158
161
164
166
144
153
159
164
168
SHC
-45
-45
-43
-40
-36
-31
-27
-71
-74
-75
-75
-74
40
kW
21.7
21.8
22.0
22.1
22.3
22.4
22.5
22.5
22.6
22.7
22.9
23.0
BF
0.02
0.07
0.10
0.12
0.15
0.16
0.18
0.00
0.01
0.05
0.09
0.12

13,500
155
-82
25.1
0.15
159
-80
24.5
0.15
163
-78
24.0
0.15
156
-80
25.0
0.15
163
-76
24.0
0.15
171
-72
23.1
0.15

15,000
157
-80
25.1
0.17
161
-78
24.6
0.17
165
-76
24.1
0.17
157
-78
25.1
0.17
165
-74
24.1
0.17
173
-70
23.2
0.17

LEGEND
BF Bypass Factor
RH
Relative Humidity
Edb Entering Dry Bulb
SHC Sensible Heat Cap. (1000 Btuh)
Ewb Entering Wet Bulb
TC
Total Cap. (1000 Btuh) Gross
kW Compressor Motor Power
Input
NOTES:
1. The SHC is based on 75 F edb temperature of air entering evaporator coil. For edb temperatures other than 75 F, adjust SHC by
multiplying the correction factor and the cfm and then adding or
subtracting the value from the SHC.
2. Interpolation is permissible.
3. Correction Factor = 1.10 x (1 BF) x (edb 75).
4. Cooling capacities are gross and do not include deduction for
indoor fan motor heat.
5. Capacity table includes impact of outdoor fan staging at temperatures below 75 F.

48

6. SHC values provided reflect maximum reheat values with 100%


gas bypass. Negative SHC value indicates that the air entering
the coil is being heated at 100% gas bypass. The P Series innovative modulating valve system will reduce the gas bypass as
required to meet the supply air setpoint with minimal change in
latent capacity. The space will NOT be overheated and the unit
will provide variable SHC to meet the space load.

COOLING CAPACITIES (cont)


48/50P2,P3,P4,P5030 (30 TON) HIGH-CAPACITY COIL STANDARD MODE
Evaporator Air Quantity Cfm
Temp (F)
6,000
7,500
9,000
Air Entering
Condenser
Evaporator Air Ewb (F)
(Edb)
75
72
67
62
57
75
72
67
62
57
75
72
67
TC
384 367 338 312 289 405 386 356 329 307 418 400 369
SHC
158 177 211 245 277 164 192 233 274 300 175 205 253
75
kW
22.8 22.3 21.5 20.8 20.3 23.3 22.8 21.9 21.2 20.6 23.7 23.1 22.3
BF
0.00 0.00 0.10 0.07 0.07 0.00 0.16 0.09 0.08 0.17 0.13 0.14 0.11
TC
373 356 330 305 282 392 373 346 322 299 404 386 358
SHC
153 172 208 241 272 161 187 229 270 299 170 200 248
85
kW
25.0 24.5 23.7 23.2 22.9 25.5 25.0 24.2 23.6 23.1 25.9 25.3 24.5
BF
0.00 0.00 0.09 0.07 0.07 0.00 0.14 0.09 0.08 0.15 0.22 0.13 0.10
TC
360 346 322 297 272 377 362 337 312 291 389 374 348
SHC
148 169 204 237 266 156 183 225 266 291 165 196 244
95
kW
27.5 27.1 26.5 26.1 26.0 28.0 27.6 26.9 26.5 26.2 28.4 27.9 27.2
BF
0.00 0.10 0.09 0.07 0.07 0.00 0.13 0.09 0.08 0.17 0.19 0.12 0.10
TC
350 336 311 285 260 365 351 326 300 281 377 362 336
SHC
144 165 199 231 257 152 179 220 260 281 161 191 239
105
kW
30.5 30.2 29.8 29.6 29.9 31.0 30.7 30.2 29.9 29.8 31.4 31.0 30.5
BF
0.00 0.17 0.08 0.06 0.09 0.13 0.12 0.09 0.07 0.20 0.17 0.12 0.10
TC
338 323 297 272 247 351 337 310 285 269 362 346 320
SHC
138 160 193 225 246 148 173 214 253 269 156 186 233
115
kW
34.1 33.9 33.7 33.9 34.8 34.5 34.4 34.1 34.1 34.5 35.0 34.7 34.3
BF
0.00 0.14 0.07 0.06 0.12 0.20 0.11 0.08 0.07 0.23 0.15 0.11 0.10

10,500
62
341
300
21.5
0.09
333
296
23.9
0.09
323
292
26.7
0.09
310
285
30.3
0.09
294
278
34.5
0.10

57
323
323
21.1
0.23
317
317
23.5
0.24
309
309
26.5
0.26
298
298
30.0
0.29
285
285
34.4
0.32

75
429
183
23.9
0.20
414
179
26.1
0.18
399
174
28.7
0.16
386
170
31.7
0.15
370
164
35.3
0.14

72
410
217
23.4
0.14
395
212
25.6
0.13
383
208
28.2
0.13
370
203
31.3
0.12
353
197
35.0
0.12

67
378
271
22.5
0.12
367
267
24.8
0.11
356
263
27.5
0.11
343
257
30.7
0.11
326
251
34.5
0.11

62
351
325
21.8
0.11
342
321
24.1
0.11
331
315
27.0
0.12
317
307
30.5
0.12
302
295
34.5
0.15

57
338
338
21.5
0.31
331
331
23.9
0.32
323
323
26.8
0.34
312
312
30.3
0.36
299
299
34.5
0.39

48/50P2,P3,P4,P5030 (30 TON) HIGH-CAPACITY COIL STANDARD MODE (cont)


Evaporator Air Quantity Cfm
Temp (F)
12,000
13,500
15,000
Air Entering
Condenser
Evaporator Air Ewb (F)
(Edb)
75
72
67
62
57
75
72
67
62
57
75
72
67
62
57
TC
437 417 385 356 350 444 423 391 361 360 449 428 396 370 369
SHC
191 229 289 343 350 199 240 306 358 360 206 250 323 370 369
75
kW
24.2 23.6 22.7 21.9 21.8 24.3 23.8 22.9 22.1 22.1 24.5 23.9 23.0 22.3 22.3
BF
0.18 0.14 0.13 0.14 0.37 0.18 0.15 0.14 0.19 0.43 0.18 0.15 0.15 0.24 0.47
421 402 373 348 343 427 407 378 353 353 432 412 382 362 361
TC
SHC
186 223 284 338 343 193 234 301 351 353 200 245 318 362 361
85
kW
26.4 25.8 25.0 24.3 24.2 26.5 26.0 25.1 24.4 24.4 26.6 26.1 25.2 24.7 24.7
BF
0.17 0.14 0.12 0.15 0.39 0.17 0.14 0.14 0.20 0.44 0.17 0.15 0.15 0.26 0.48
TC
406 389 362 337 334 411 395 367 344 344 416 399 370 352 352
SHC
181 219 280 331 334 188 230 297 344 344 195 240 313 352 352
95
kW
28.9 28.4 27.7 27.1 27.0 29.0 28.6 27.8 27.3 27.3 29.2 28.7 27.9 27.5 27.5
BF
0.16 0.13 0.12 0.16 0.40 0.16 0.14 0.13 0.22 0.45 0.17 0.16 0.14 0.28 0.50
392 376 348 324 323 397 380 353 333 332 402 384 356 340 340
TC
SHC
177 214 275 321 323 184 225 292 329 332 191 235 308 340 340
105
kW
31.9 31.5 30.9 30.4 30.5 32.1 31.7 31.0 30.6 30.7 32.3 31.8 31.2 30.9 30.9
BF
0.15 0.13 0.12 0.18 0.42 0.16 0.14 0.13 0.26 0.47 0.16 0.16 0.15 0.30 0.51
TC
375 359 331 311 309 380 363 335 318 318 384 366 338 325 325
SHC
172 209 268 304 309 179 219 285 318 318 185 229 301 325 325
115
kW
35.5 35.2 34.6 34.3 34.5 35.7 35.3 34.8 34.7 34.6 35.9 35.5 34.9 34.8 34.7
BF
0.15 0.13 0.12 0.23 0.45 0.15 0.14 0.13 0.27 0.49 0.16 0.15 0.15 0.33 0.53
LEGEND
3. SHC is based on 80 F edb temperature of air entering evaporator
coil.
48/50P3,P5 units only.
Below 80 F edb, subtract (corr factor x cfm) from SHC.
Above 80 F edb, add (corr factor x cfm) to SHC.
BF Bypass Factor
kW
Compressor Motor Power Input
Edb Entering Dry Bulb
SHC Sensible Heat Cap. (1000 Btuh)
Ewb Entering Wet Bulb
TC
Total Cap. (1000 Btuh) Gross
ENTERING AIR DRY-BULB TEMP (F)
79
78
77
76
75
under 75
NOTES:
BF
81
82
83
84
85
over 85
1. Direct interpolation is permissible. Do not extrapolate.
2. The following formulas may be used:
Correction Factor
sensible capacity (Btuh)
.05
1.04
2.09
3.14
4.18
5.22
tldb = tedb
Use formula
.10
0.99
1.98
2.97
3.96
4.95 shown below
1.10 x cfm
.20
0.88
1.76
2.64
3.52
4.40
Wet-bulb temperature corresponding to enthalpy of air
tlwb =
leaving evaporator coil (hlwb).
Interpolation is permissible.
Correction Factor = 1.10 x (1 BF) x (edb 80).
total capacity (Btuh)
hlwb = hewb
4. Cooling capacities are gross and do not include deduction for indoor
4.5 x cfm
fan motor heat.
Where: h
= Enthalpy of air entering evaporator coil.
ewb

49

Performance data (cont)


COOLING CAPACITIES (cont)
48/50P2,P3,P4,P5030 (30 TON) HIGH-CAPACITY COIL SUBCOOL MODE
Evaporator Air Quantity Cfm
Temp (F)
6,000
7,500
9,000
Air Entering
Condenser
Evaporator Air Ewb (F)
(Edb)
75
72
67
62
57
75
72
67
62
57
75
72
67
TC
353 332 300 272 249 374 351 318 288 268 389 365 330
SHC
98
119 153 188 225 106 131 171 214 252 114 142 190
75
24.1 23.5 22.6 22.0 21.4 24.8 24.1 23.2 22.4 21.8 25.3 24.6 23.6
kW
BF
0.00 0.01 0.03 0.03 0.05 0.01 0.03 0.04 0.05 0.11 0.02 0.04 0.05
TC
329 310 280 254 233 346 326 294 267 251 359 337 305
78
100 136 172 211
83
109 151 196 236
90
119 168
SHC
85
kW
26.2 25.6 24.8 24.2 23.7 26.8 26.2 25.2 24.5 24.0 27.3 26.6 25.6
BF
0.00 0.01 0.03 0.03 0.05 0.01 0.03 0.04 0.05 0.12 0.02 0.04 0.05
TC
306 287 259 234 219 319 300 271 246 234 329 309 279
SHC
59
81
118 155 198
61
87
131 177 219
65
95
146
95
kW
28.6 28.0 27.3 26.7 26.3 29.1 28.5 27.6 27.0 26.6 29.5 28.8 27.9
0.00 0.01 0.03 0.03 0.07 0.01 0.03 0.04 0.05 0.13 0.02 0.04 0.05
BF
TC
281 264 238 215 204 291 273 247 224 216 299 280 253
SHC
39
62
101 140 183
38
65
112 160 202
40
71
124
105
31.2 30.7 30.1 29.5 29.2 31.7 31.1 30.3 29.7 29.4 32.0 31.4 30.5
kW
BF
0.00 0.01 0.03 0.03 0.09 0.01 0.03 0.04 0.05 0.14 0.03 0.05 0.06
TC
256 240 216 195 188 263 246 222 202 198 267 251 226
SHC
19
43
84
124 168
15
44
92
142 185
15
47
103
115
kW
34.2 33.8 33.2 32.9 32.8 34.5 34.0 33.3 32.9 32.7 34.7 34.2 33.4
BF
0.00 0.02 0.03 0.03 0.10 0.01 0.03 0.04 0.05 0.16 0.03 0.05 0.06

62
300
239
22.7
0.06
277
219
24.8
0.06
254
199
27.2
0.07
231
180
29.9
0.07
208
162
32.9
0.08

57
282
275
22.2
0.16
263
257
24.3
0.17
244
238
26.8
0.18
225
219
29.6
0.19
205
200
32.8
0.21

48/50P2,P3,P4,P5030 (30 TON) HIGH-CAPACITY COIL SUBCOOL MODE (cont)


Evaporator Air Quantity Cfm
Temp (F)
12,000
13,500
Air Entering
Condenser
Evaporator Air Ewb (F)
(Edb)
75
72
67
62
57
75
72
67
62
57
75
TC
396 386 348 316 305 405 388 355 324 316 409
SHC
123 167 226 282 305 130 174 245 298 316 132
75
kW
25.5 25.3 24.2 23.2 22.9 25.6 25.4 24.4 23.4 23.2 25.8
BF
0.06 0.07 0.08 0.12 0.30 0.07 0.09 0.09 0.16 0.36 0.09
TC
375 354 319 293 282 383 359 325 300 292 389
SHC
102 140 202 258 282 111 151 219 273 292 114
85
kW
27.9 27.2 26.1 25.2 24.9 28.2 27.4 26.3 25.5 25.2 28.4
BF
0.06 0.07 0.08 0.13 0.30 0.07 0.09 0.09 0.17 0.36 0.08
TC
343 322 291 269 260 348 327 295 275 268 352
SHC
76
114 177 235 260
82
123 193 249 268
88
95
kW
30.1 29.4 28.3 27.6 27.3 30.3 29.6 28.5 27.8 27.6 30.5
BF
0.06 0.07 0.08 0.14 0.31 0.08 0.09 0.10 0.18 0.37 0.09
TC
310 290 261 245 237 313 293 264 250 243 317
SHC
48
87
153 212 237
53
95
167 225 243
59
105
kW
32.5 31.8 30.8 30.2 30.0 32.7 32.0 31.0 30.4 30.2 32.8
BF
0.06 0.07 0.08 0.16 0.33 0.08 0.09 0.10 0.19 0.38 0.09
TC
275 257 231 221 213 277 259 234 224 218 279
SHC
20
59
129 189 213
23
67
142 201 218
28
115
kW
35.1 34.5 33.7 33.2 33.0 35.2 34.6 33.7 33.3 33.2 35.4
BF
0.06 0.08 0.08 0.17 0.34 0.08 0.09 0.10 0.21 0.40 0.09

62
331
314
23.7
0.19
306
289
25.7
0.20
279
263
27.9
0.21
253
238
30.5
0.22
227
212
33.4
0.24

57
326
326
23.5
0.41
300
300
25.5
0.41
275
275
27.8
0.42
249
249
30.4
0.43
223
223
33.3
0.44

LEGEND
48/50P3,P5 units only.
BF Bypass Factor
kW
Compressor Motor Power Input
Edb Entering Dry Bulb
SHC Sensible Heat Cap. (1000 Btuh)
Ewb Entering Wet Bulb
TC
Total Cap. (1000 Btuh) Gross
NOTES:
1. The SHC is based on 80 F edb temperature of air entering evaporator coil. For edb temperatures other than 80 F, adjust SHC by
multiplying the correction factor and the cfm and then adding or
subtracting the value from the SHC.

50

10,500
75
398
121
25.6
0.04
369
97
27.6
0.04
337
70
29.8
0.04
305
44
32.3
0.04
271
17
34.9
0.04

72
377
155
25.0
0.06
346
129
26.9
0.06
317
104
29.1
0.06
286
79
31.6
0.06
254
53
34.3
0.06

67
340
208
23.9
0.07
313
185
25.9
0.07
286
162
28.1
0.07
257
138
30.7
0.07
229
115
33.6
0.07

62
309
262
23.0
0.08
285
241
25.0
0.09
261
220
27.4
0.09
239
200
30.1
0.11
216
177
33.1
0.13

57
292
292
22.5
0.22
272
272
24.6
0.23
251
251
27.1
0.25
229
229
29.8
0.26
207
207
32.9
0.28

15,000
72
401
192
25.8
0.10
365
162
27.6
0.10
331
133
29.7
0.10
297
105
32.1
0.10
261
75
34.7
0.10

67
361
263
24.6
0.11
329
235
26.5
0.11
298
208
28.6
0.11
267
181
31.1
0.11
235
156
33.8
0.12

2. Interpolation is permissible.
3. Correction Factor = 1.10 x (1 BF) x (edb 80).
4. Cooling capacities are gross and do not include deduction for
indoor fan motor heat.
5. SHC values provided are in subcooling mode with the gas bypass
valve closed and reflect the maximum SHC in subcooling mode.
The P Series innovative modulating valve system can reduce SHC
as needed to meet the supply air set point requirement with minimal change in latent capacity. This will provide variable SHC to
meet the space load.

COOLING CAPACITIES (cont)


48/50P2,P3,P4,P5030 (30 TON) HIGH-CAPACITY COIL HOT GAS REHEAT MODE
Air Entering Evaporator Ewb (F)
Temp (F)
75 Dry Bulb
75 Dry Bulb
Air Ent
62.5 Wet Bulb (50% RH)
65.3 Wet Bulb (60% RH)
Condenser
Air Entering Evaporator Cfm
(Edb)
6000
7500
9000
10,500
12,000
13,500
15,000
6000
7500
9000
10,500
12,000
TC
126
135
141
145
148
150
152
133
142
148
152
154
SHC
8
18
29
41
54
67
79
-20
-15
-8
-0
8
80
kW
23.4
23.3
23.3
23.4
23.4
23.5
23.6
24.0
23.9
23.9
24.0
24.0
BF
0.03
0.04
0.06
0.07
0.08
0.10
0.11
0.02
0.04
0.05
0.07
0.08
TC
129
138
144
148
151
153
155
136
145
150
154
157
SHC
9
19
31
43
55
68
81
-18
-13
-7
1
10
75
kW
22.7
22.6
22.6
22.7
22.8
22.8
22.9
23.3
23.2
23.3
23.4
23.4
BF
0.03
0.04
0.06
0.07
0.08
0.10
0.11
0.02
0.04
0.05
0.07
0.08
TC
131
141
146
150
153
156
158
138
147
153
157
160
SHC
11
21
32
44
57
69
82
-17
-12
-5
2
11
70
kW
22.0
22.0
22.0
22.1
22.2
22.3
22.4
22.7
22.6
22.7
22.8
22.9
BF
0.03
0.04
0.06
0.07
0.08
0.10
0.11
0.02
0.04
0.05
0.07
0.08
TC
130
138
144
147
150
152
154
136
144
149
153
156
SHC
11
20
31
43
55
68
81
-17
-13
-6
1
10
60
kW
22.7
22.7
22.9
23.0
23.1
23.2
23.3
23.4
23.5
23.6
23.8
23.9
BF
0.03
0.04
0.06
0.07
0.08
0.10
0.11
0.02
0.04
0.05
0.07
0.08
TC
134
143
148
152
155
157
159
140
149
154
158
161
SHC
13
23
34
45
58
71
84
-15
-10
-4
4
13
50
kW
21.4
21.6
21.7
21.9
22.0
22.2
22.3
22.2
22.3
22.5
22.7
22.8
BF
0.03
0.04
0.06
0.07
0.08
0.10
0.11
0.02
0.04
0.05
0.07
0.08
TC
138
147
152
157
161
164
166
144
153
160
165
168
SHC
16
25
36
48
61
74
87
-13
-8
-1
7
16
40
kW
20.4
20.6
20.8
21.0
21.1
21.3
21.4
21.2
21.4
21.6
21.7
21.9
BF
0.03
0.04
0.06
0.07
0.08
0.09
0.11
0.02
0.04
0.05
0.07
0.08

13,500
157
17
24.1
0.09
159
19
23.5
0.09
163
20
23.0
0.09
158
19
24.0
0.09
164
22
22.9
0.09
171
26
22.0
0.09

15,000
158
27
24.2
0.10
161
28
23.6
0.10
165
30
23.1
0.10
160
29
24.1
0.10
166
32
23.0
0.10
173
36
22.2
0.10

48/50P2,P3,P4,P5030 (30 TON) HIGH-CAPACITY COIL HOT GAS REHEAT MODE (cont)
Air Entering Evaporator Ewb (F)
Temp (F)
75 Dry Bulb
75 Dry Bulb
Air Ent
68 Wet Bulb (70% RH)
70.5 Wet Bulb (80% RH)
Condenser
Air Entering Evaporator Cfm
(Edb)
6000
7500
9000
10,500
12,000
13,500
15,000
6000
7500
9000
10,500
12,000
TC
139
148
154
158
161
163
165
145
154
160
164
167
SHC
-48
-47
-44
-41
-36
-31
-25
-74
-77
-79
-79
-77
80
kW
24.7
24.6
24.6
24.6
24.7
24.8
24.9
25.4
25.3
25.3
25.4
25.4
BF
0.01
0.03
0.04
0.06
0.07
0.09
0.10
0.00
0.00
0.02
0.04
0.06
TC
142
151
156
160
164
167
169
148
157
163
167
171
SHC
-46
-45
-43
-39
-34
-29
-23
-73
-76
-77
-77
-75
75
kW
24.0
23.9
24.0
24.1
24.2
24.2
24.3
24.8
24.7
24.7
24.8
24.9
BF
0.01
0.03
0.04
0.06
0.07
0.09
0.10
0.00
0.00
0.02
0.04
0.06
TC
144
153
159
164
168
171
173
150
159
166
171
175
SHC
-45
-44
-42
-38
-33
-27
-21
-71
-74
-76
-75
-73
70
kW
23.4
23.4
23.4
23.5
23.6
23.7
23.8
24.1
24.1
24.2
24.3
24.3
BF
0.01
0.02
0.04
0.06
0.07
0.09
0.10
0.00
0.00
0.02
0.04
0.06
TC
142
150
155
159
162
164
166
147
155
161
165
167
SHC
-45
-45
-43
-39
-34
-29
-23
-72
-76
-77
-77
-75
60
kW
24.2
24.3
24.4
24.6
24.7
24.8
24.9
25.1
25.1
25.2
25.3
25.4
BF
0.01
0.03
0.04
0.06
0.07
0.09
0.10
0.00
0.00
0.02
0.04
0.06
TC
146
155
160
165
168
171
173
152
160
167
172
175
SHC
-43
-43
-40
-36
-31
-25
-19
-69
-73
-74
-73
-72
50
kW
23.0
23.2
23.3
23.5
23.6
23.7
23.8
23.9
24.0
24.1
24.3
24.4
BF
0.01
0.03
0.04
0.06
0.07
0.09
0.10
0.00
0.00
0.02
0.04
0.06
TC
150
160
167
172
176
179
181
157
167
174
179
183
SHC
-41
-40
-37
-32
-27
-21
-15
-67
-70
-70
-70
-68
40
kW
22.0
22.2
22.4
22.6
22.7
22.8
22.9
22.9
23.0
23.2
23.3
23.5
BF
0.01
0.02
0.04
0.06
0.07
0.09
0.10
0.00
0.00
0.02
0.04
0.06

13,500
170
-75
25.5
0.07
174
-73
24.9
0.07
178
-71
24.4
0.07
170
-73
25.5
0.08
178
-69
24.5
0.07
186
-65
23.6
0.07

15,000
172
-72
25.5
0.09
176
-70
25.0
0.09
180
-68
24.5
0.09
172
-71
25.6
0.09
180
-66
24.6
0.09
188
-62
23.7
0.09

LEGEND
BF Bypass Factor
RH
Relative Humidity
Edb Entering Dry Bulb
SHC Sensible Heat Cap. (1000 Btuh)
Ewb Entering Wet Bulb
TC
Total Cap. (1000 Btuh) Gross
kW Compressor Motor Power
Input

6. SHC values provided reflect maximum reheat values with 100%


gas bypass. Negative SHC value indicates that the air entering
the coil is being heated at 100% gas bypass. The P Series innovative modulating valve system will reduce the gas bypass as
required to meet the supply air setpoint with minimal change in
latent capacity. The space will NOT be overheated and the unit
will provide variable SHC to meet the space load.

NOTES:
1. The SHC is based on 75 F edb temperature of air entering evaporator coil. For edb temperatures other than 75 F, adjust SHC by
multiplying the correction factor and the cfm and then adding or
subtracting the value from the SHC.
2. Interpolation is permissible.
3. Correction Factor = 1.10 x (1 BF) x (edb 75).
4. Cooling capacities are gross and do not include deduction for
indoor fan motor heat.
5. Capacity table includes impact of outdoor fan staging at temperatures below 75 F.

51

Performance data (cont)


COOLING CAPACITIES (cont)
48/50P2,P3,P4,P5035 (35 TON) STANDARD CAPACITY COIL STANDARD MODE
Evaporator Air Quantity Cfm
Temp (F)
7,000
8,750
9,625
Air Entering
Condenser
Evaporator Air Ewb (F)
(Edb)
75
72
67
62
57
75
72
67
62
57
75
72
67
TC
437 419 387 358 332 459 439 407 377 352 466 446 414
SHC
177 200 242 281 318 183 216 266 313 343 190 224 277
75
kW
27.0 26.3 25.3 24.4 23.8 27.7 27.0 25.9 24.9 24.2 27.9 27.2 26.1
BF
0.00 0.00 0.11 0.08 0.08 0.00 0.18 0.11 0.10 0.18 0.00 0.16 0.12
TC
424 406 377 350 323 444 424 395 368 344 450 432 402
SHC
172 196 237 277 313 180 211 261 309 339 185 218 272
85
kW
29.5 28.8 27.8 27.0 26.6 30.1 29.4 28.4 27.5 26.9 30.4 29.7 28.6
BF
0.00 0.00 0.10 0.08 0.08 0.00 0.16 0.11 0.09 0.18 0.00 0.15 0.12
TC
409 394 368 340 311 427 411 384 357 333 433 418 391
SHC
166 191 233 272 304 175 206 256 304 333 179 214 267
95
kW
32.3 31.7 30.9 30.3 30.0 32.9 32.3 31.4 30.7 30.4 33.2 32.5 31.6
BF
0.00 0.10 0.10 0.08 0.09 0.00 0.15 0.10 0.09 0.18 0.27 0.14 0.11
TC
398 382 355 327 298 413 399 371 343 321 419 405 377
SHC
161 187 228 265 295 170 202 251 297 321 175 209 262
105
kW
35.7 35.2 34.6 34.2 34.4 36.3 35.8 35.1 34.6 34.4 36.5 36.0 35.3
BF
0.00 0.18 0.09 0.08 0.11 0.14 0.14 0.10 0.09 0.21 0.21 0.13 0.11
TC
383 367 339 311 284 397 382 354 326 308 403 388 359
SHC
154 181 221 258 283 165 196 243 290 308 170 203 254
115
kW
39.6 39.3 38.9 39.1 39.9 40.2 39.9 39.4 39.3 39.7 40.5 40.1 39.6
BF
0.00 0.15 0.09 0.07 0.14 0.22 0.13 0.10 0.09 0.24 0.18 0.13 0.11

10,500
62
384
328
25.1
0.10
375
325
27.7
0.10
363
319
30.9
0.10
349
313
34.8
0.10
332
304
39.5
0.10

57
361
361
24.5
0.20
353
353
27.2
0.21
344
344
30.6
0.23
332
332
34.6
0.26
318
318
39.6
0.29

75
472
195
28.1
0.14
456
190
30.6
0.25
438
184
33.4
0.21
425
180
36.7
0.19
408
175
40.7
0.17

72
453
231
27.4
0.16
438
225
29.9
0.15
423
220
32.7
0.14
410
216
36.2
0.13
393
210
40.3
0.13

67
420
288
26.3
0.12
408
283
28.8
0.12
397
278
31.8
0.12
382
272
35.4
0.12
364
265
39.7
0.11

62
389
343
25.3
0.11
380
339
27.9
0.11
369
334
31.1
0.11
354
326
35.1
0.11
336
318
39.8
0.11

57
370
370
24.7
0.24
363
363
27.4
0.26
353
353
30.8
0.28
341
341
34.8
0.30
327
327
39.7
0.33

48/50P2,P3,P4,P5035 (35 TON) STANDARD CAPACITY COIL STANDARD MODE (cont)


Evaporator Air Quantity Cfm
Temp (F)
12,225
14,000
15,000
Air Entering
Condenser
Evaporator Air Ewb (F)
(Edb)
75
72
67
62
57
75
72
67
62
57
75
72
67
62
57
TC
482 463 430 400 386 491 471 438 406 400 496 475 442 411 406
SHC
204 244 309 371 386 213 257 329 391 400 218 264 340 400 406
75
kW
28.5 27.8 26.6 25.6 25.2 28.8 28.0 26.9 25.8 25.6 28.9 28.2 27.0 26.0 25.8
BF
0.22 0.16 0.13 0.13 0.32 0.20 0.16 0.14 0.16 0.39 0.20 0.16 0.15 0.19 0.42
TC
466 447 417 390 379 475 455 424 397 392 478 458 427 400 398
SHC
199 239 303 366 379 208 252 323 386 392 212 259 334 395 398
85
kW
30.9 30.2 29.1 28.2 27.9 31.2 30.5 29.3 28.4 28.3 31.4 30.6 29.4 28.5 28.5
BF
0.20 0.15 0.13 0.13 0.34 0.19 0.16 0.14 0.17 0.40 0.19 0.16 0.15 0.20 0.43
TC
449 433 405 378 369 456 439 412 385 382 460 442 415 389 388
SHC
193 234 299 360 369 202 246 319 377 382 206 253 330 381 388
95
kW
33.7 33.1 32.1 31.4 31.1 34.0 33.3 32.3 31.6 31.5 34.1 33.4 32.4 31.6 31.6
BF
0.18 0.14 0.13 0.13 0.35 0.18 0.15 0.14 0.17 0.42 0.18 0.16 0.15 0.23 0.45
TC
435 418 390 362 356 441 425 396 370 369 444 428 399 376 375
SHC
189 229 293 348 356 197 241 313 363 369 202 249 324 368 375
105
kW
37.1 36.5 35.7 35.2 35.1 37.4 36.8 35.9 35.3 35.3 37.5 36.9 36.0 35.4 35.5
BF
0.17 0.14 0.13 0.15 0.38 0.17 0.15 0.14 0.21 0.44 0.17 0.15 0.15 0.26 0.46
TC
417 400 371 345 341 423 406 377 355 353 425 409 380 359 359
SHC
183 223 286 337 341 192 235 305 347 353 196 242 317 359 359
115
kW
41.1 40.6 39.9 39.8 39.8 41.4 40.9 40.1 39.6 39.9 41.5 41.0 40.2 40.0 40.0
BF
0.16 0.14 0.13 0.17 0.40 0.16 0.14 0.14 0.25 0.46 0.17 0.15 0.15 0.26 0.49
Where: hewb = Enthalpy of air entering evaporator coil.
LEGEND
3. SHC is based on 80 F edb temperature of air entering evaporator
48/50P3,P5 units only.
coil.
Below 80 F edb, subtract (corr factor x cfm) from SHC.
BF Bypass Factor
kW
Compressor Motor Power Input
Above 80 F edb, add (corr factor x cfm) to SHC.
Edb Entering Dry Bulb
SHC Sensible Heat Cap. (1000 Btuh)
Ewb Entering Wet Bulb
TC
Total Cap. (1000 Btuh) Gross
ENTERING AIR DRY-BULB TEMP (F)
NOTES:
79
78
77
76
75
under 75
1. Direct interpolation is permissible. Do not extrapolate.
BF
2. The following formulas may be used:
81
82
83
84
85
over 85
Correction Factor
sensible capacity (Btuh)
tldb = tedb
.05
1.04
2.09
3.14
4.18
5.22
1.10 x cfm
Use formula
.10
0.99
1.98
2.97
3.96
4.95
.20
0.88
1.76
2.64
3.52
4.40 shown below
Wet-bulb temperature corresponding to enthalpy of air
tlwb =
leaving evaporator coil (hlwb).
Interpolation is permissible.
Correction Factor = 1.10 x (1 BF) x (edb 80).
total capacity (Btuh)
hlwb = hewb
4. Cooling capacities are gross and do not include deduction for indoor
4.5 x cfm
fan motor heat.

52

COOLING CAPACITIES (cont)


48/50P2,P3,P4,P5035 (35 TON) STANDARD CAPACITY COIL SUBCOOL MODE
Evaporator Air Quantity Cfm
Temp (F)
7,000
8,750
9,625
Air Entering
Condenser
Evaporator Air Ewb (F)
(Edb)
75
72
67
62
57
75
72
67
62
57
75
72
67
TC
388 364 328 297 270 410 385 346 313 290 413 393 354
SHC
112 134 172 211 249 123 149 194 241 281 124 157 206
75
26.3 25.6 24.5 23.7 23.0 27.0 26.2 25.1 24.2 23.5 27.2 26.5 25.3
kW
BF
0.00 0.01 0.04 0.04 0.05 0.01 0.04 0.05 0.06 0.12 0.02 0.05 0.06
TC
360 337 304 275 251 378 355 319 289 270 386 362 325
88
112 151 192 233
97
125 171 220 261 102 131 181
SHC
85
kW
28.4 27.7 26.7 25.9 25.3 29.1 28.3 27.2 26.3 25.7 29.4 28.6 27.4
BF
0.00 0.02 0.04 0.04 0.06 0.01 0.04 0.05 0.06 0.13 0.02 0.05 0.06
TC
331 311 280 253 235 346 324 292 265 250 352 330 297
SHC
65
89
130 173 218
71
99
148 199 242
74
105 157
95
kW
30.8 30.1 29.1 28.4 27.9 31.4 30.7 29.6 28.8 28.3 31.7 30.9 29.8
0.00 0.02 0.04 0.04 0.08 0.02 0.04 0.05 0.06 0.14 0.02 0.05 0.06
BF
303 284 256 230 217 314 294 265 240 229 318 298 269
TC
SHC
42
67
110 154 200
44
74
125 178 222
47
78
133
105
33.5 32.8 32.0 31.3 30.9 34.0 33.3 32.3 31.6 31.2 34.2 33.5 32.5
kW
BF
0.00 0.02 0.04 0.04 0.09 0.02 0.04 0.05 0.06 0.16 0.03 0.05 0.06
TC
274 256 230 207 188 281 263 237 216 198 284 266 239
SHC
18
45
90
135 172
18
49
103 153 192
19
52
110
115
kW
36.5 35.9 35.2 34.6 34.0 36.9 36.3 35.4 34.8 34.3 37.1 36.4 35.5
0.00 0.02 0.04 0.04 0.11 0.02 0.04 0.05 0.06 0.17 0.03 0.05 0.06
BF

62
319
255
24.3
0.07
294
234
26.5
0.07
269
212
28.9
0.07
244
190
31.7
0.07
207
160
34.7
0.08

57
297
294
23.7
0.15
276
273
25.9
0.16
255
253
28.4
0.17
225
223
31.2
0.19
199
199
34.4
0.20

48/50P2,P3,P4,P5035 (35 TON) STANDARD CAPACITY COIL SUBCOOL MODE (cont)


Evaporator Air Quantity Cfm
Temp (F)
12,225
14,000
Air Entering
Condenser
Evaporator Air Ewb (F)
(Edb)
75
72
67
62
57
75
72
67
62
57
75
72
TC
435 407 372 335 320 451 413 377 343 334 441 427
SHC
142 175 239 297 320 159 186 258 322 334 150 204
75
kW
27.9 27.0 25.9 24.8 24.4 28.4 27.2 26.1 25.1 24.8 28.0 27.6
BF
0.06 0.07 0.08 0.10 0.28 0.08 0.09 0.10 0.13 0.35 0.09 0.10
TC
402 378 340 307 296 404 386 347 315 307 420 391
SHC
114 152 213 272 296 118 165 233 291 307 134 174
85
kW
30.0 29.2 27.9 26.9 26.5 30.0 29.5 28.2 27.2 26.9 30.6 29.7
BF
0.06 0.07 0.08 0.11 0.29 0.08 0.09 0.10 0.15 0.36 0.09 0.10
TC
366 343 308 277 271 373 349 313 288 281 376 353
SHC
85
122 186 247 271
93
135 205 265 281
97
142
95
kW
32.3 31.4 30.2 29.2 29.0 32.5 31.7 30.5 29.5 29.3 32.7 31.9
BF
0.06 0.08 0.08 0.11 0.30 0.08 0.09 0.10 0.16 0.37 0.09 0.10
TC
328 307 277 255 246 334 312 281 261 255 337 314
SHC
55
93
159 223 246
62
104 177 239 255
66
110
105
kW
34.7 33.9 32.8 32.0 31.8 35.0 34.2 33.0 32.3 32.1 35.1 34.3
BF
0.06 0.08 0.08 0.13 0.31 0.08 0.09 0.10 0.17 0.38 0.09 0.10
TC
291 272 240 219 208 295 275 243 223 215 296 276
SHC
24
64
128 187 208
29
74
145 202 215
33
78
115
kW
37.5 36.7 35.6 35.0 34.8 37.7 36.9 35.8 35.2 35.1 37.8 37.0
BF
0.06 0.08 0.08 0.15 0.33 0.08 0.09 0.10 0.19 0.39 0.09 0.10

62
349
331
25.3
0.16
320
302
27.3
0.17
292
275
29.7
0.18
264
248
32.4
0.20
224
209
35.3
0.21

57
342
342
25.1
0.38
314
314
27.1
0.39
287
287
29.5
0.40
259
259
32.2
0.41
219
219
35.2
0.42

LEGEND
48/50P3,P5 units only.
BF Bypass Factor
kW
Compressor Motor Power Input
Edb Entering Dry Bulb
SHC Sensible Heat Cap. (1000 Btuh)
Ewb Entering Wet Bulb
TC
Total Cap. (1000 Btuh) Gross
NOTES:
1. The SHC is based on 80 F edb temperature of air entering evaporator coil. For edb temperatures other than 80 F, adjust SHC by
multiplying the correction factor and the cfm and then adding or
subtracting the value from the SHC.

10,500
75
419
127
27.3
0.03
392
106
29.6
0.04
357
78
31.9
0.04
322
49
34.4
0.04
287
20
37.2
0.04

72
401
165
26.8
0.06
368
138
28.8
0.06
335
111
31.1
0.06
301
83
33.7
0.06
269
56
36.5
0.06

67
360
217
25.6
0.07
330
192
27.6
0.07
302
167
30.0
0.07
272
142
32.6
0.07
237
112
35.5
0.07

62
325
270
24.5
0.08
299
247
26.6
0.08
273
224
29.1
0.08
247
202
31.8
0.08
210
169
34.8
0.09

57
304
304
23.9
0.19
282
282
26.1
0.20
259
259
28.6
0.22
236
236
31.5
0.23
200
200
34.5
0.25

15,000
67
381
269
26.2
0.10
350
244
28.3
0.10
316
216
30.6
0.11
283
187
33.1
0.11
245
155
35.9
0.11

2. Interpolation is permissible.
3. Correction Factor = 1.10 x (1 BF) x (edb 80).
4. Cooling capacities are gross and do not include deduction for
indoor fan motor heat.
5. SHC values provided are in subcooling mode with the gas bypass
valve closed and reflect the maximum SHC in subcooling mode.
The P Series innovative modulating valve system can reduce SHC
as needed to meet the supply air set point requirement with minimal change in latent capacity. This will provide variable SHC to
meet the space load.

53

Performance data (cont)


COOLING CAPACITIES (cont)
48/50P2,P3,P4,P5035 (35 TON) STANDARD CAPACITY COIL HOT GAS REHEAT MODE
Air Entering Evaporator Ewb (F)
Temp (F)
75 Dry Bulb
75 Dry Bulb
Air Ent
62.5 Wet Bulb (50% RH)
65.3 Wet Bulb (60% RH)
Condenser
Air Entering Evaporator Cfm
(Edb)
7000
8750
9625
10,500
12,250
14,000
15,000
7000
8750
9625
10,500
12,250
TC
150
158
161
163
167
170
171
156
164
167
170
174
SHC
24
36
43
50
64
80
88
-8
-1
3
8
18
80
kW
24.5
24.7
24.8
24.9
25.0
25.2
25.2
25.2
25.4
25.5
25.6
25.8
BF
0.04
0.05
0.06
0.07
0.08
0.10
0.11
0.03
0.05
0.06
0.07
0.08
TC
152
160
163
166
170
173
175
159
167
170
173
178
SHC
25
37
44
51
66
81
90
-6
1
5
10
20
75
kW
23.8
24.0
24.1
24.2
24.4
24.6
24.6
24.6
24.8
24.9
25.0
25.2
BF
0.04
0.05
0.06
0.07
0.08
0.10
0.11
0.03
0.05
0.06
0.07
0.08
TC
154
163
166
169
174
177
179
161
170
174
177
182
SHC
26
39
46
53
68
83
92
-5
2
7
12
22
70
kW
23.2
23.4
23.5
23.6
23.8
24.0
24.1
24.0
24.2
24.3
24.4
24.6
BF
0.04
0.05
0.06
0.07
0.08
0.10
0.11
0.03
0.05
0.06
0.07
0.08
TC
152
160
162
165
168
171
172
158
166
169
171
175
SHC
26
38
44
51
66
81
90
-6
1
5
10
20
60
kW
24.1
24.4
24.5
24.7
24.9
25.1
25.1
24.9
25.2
25.4
25.5
25.7
BF
0.04
0.05
0.06
0.07
0.08
0.10
0.11
0.03
0.05
0.06
0.07
0.08
TC
156
164
167
170
175
178
180
163
171
175
178
182
SHC
28
40
47
55
72
88
95
-3
4
9
14
24
50
kW
22.8
23.2
23.3
23.5
23.7
23.9
24.0
23.7
24.0
24.2
24.3
24.6
BF
0.04
0.05
0.06
0.07
0.08
0.10
0.11
0.03
0.05
0.06
0.07
0.08
TC
160
169
173
176
181
185
186
168
178
181
184
189
SHC
30
44
51
58
73
91
101
-0
8
12
17
28
40
kW
21.8
22.2
22.3
22.5
22.7
23.0
23.1
22.6
23.0
23.2
23.3
23.6
BF
0.04
0.05
0.06
0.07
0.08
0.10
0.11
0.03
0.05
0.06
0.07
0.08

14,000
178
29
25.9
0.10
182
31
25.3
0.10
185
33
24.7
0.10
178
31
25.9
0.10
186
37
24.8
0.10
193
43
23.8
0.10

15,000
179
36
26.0
0.10
183
38
25.4
0.10
187
40
24.8
0.10
180
38
26.0
0.10
187
45
24.9
0.10
194
49
23.9
0.10

48/50P2,P3,P4,P5035 (35 TON) STANDARD CAPACITY COIL HOT GAS REHEAT MODE (cont)
Air Entering Evaporator Ewb (F)
Temp (F)
75 Dry Bulb
75 Dry Bulb
Air Ent
68 Wet Bulb (70% RH)
70.5 Wet Bulb (80% RH)
Condenser
Air Entering Evaporator Cfm
(Edb)
7000
8750
9625
10,500
12,250
14,000
15,000
7000
8750
9625
10,500
12,250
TC
163
171
174
177
182
185
187
169
178
182
185
189
SHC
-39
-37
-34
-32
-26
-19
-15
-69
-70
-70
-69
-68
80
kW
26.0
26.2
26.3
26.4
26.5
26.7
26.7
26.8
27.0
27.1
27.1
27.3
BF
0.01
0.04
0.05
0.06
0.08
0.09
0.10
0.00
0.01
0.02
0.03
0.06
TC
165
175
178
181
186
189
191
172
182
186
189
193
SHC
-37
-35
-33
-30
-24
-17
-13
-67
-68
-68
-67
-66
75
kW
25.4
25.6
25.7
25.8
25.9
26.1
26.1
26.2
26.3
26.4
26.5
26.7
BF
0.01
0.04
0.05
0.06
0.08
0.09
0.10
0.00
0.01
0.02
0.03
0.06
TC
168
178
182
185
190
193
195
176
186
189
193
197
SHC
-36
-33
-31
-28
-22
-15
-11
-64
-66
-66
-66
-64
70
kW
24.8
25.0
25.1
25.2
25.3
25.5
25.6
25.5
25.8
25.9
25.9
26.1
BF
0.01
0.04
0.05
0.06
0.07
0.09
0.10
0.00
0.01
0.02
0.03
0.06
TC
164
172
175
178
182
185
187
170
179
182
185
189
SHC
-37
-35
-33
-30
-24
-17
-13
-66
-68
-68
-68
-66
60
kW
25.8
26.1
26.2
26.4
26.6
26.8
26.9
26.7
27.0
27.1
27.2
27.4
BF
0.01
0.04
0.05
0.06
0.08
0.09
0.10
0.00
0.01
0.02
0.03
0.06
TC
170
179
183
185
190
193
195
177
186
190
192
197
SHC
-33
-31
-29
-26
-20
-10
-5
-61
-64
-64
-64
-62
50
kW
24.5
24.9
25.1
25.2
25.4
25.7
25.8
25.4
25.8
25.9
26.1
26.3
BF
0.01
0.04
0.05
0.06
0.08
0.09
0.10
0.00
0.01
0.02
0.03
0.06
TC
175
185
189
192
197
200
202
183
193
196
199
204
SHC
-30
-28
-25
-22
-16
-9
-4
-58
-61
-61
-60
-58
40
kW
23.5
23.9
24.0
24.2
24.4
24.6
24.8
24.4
24.8
24.9
25.0
25.3
BF
0.01
0.04
0.05
0.06
0.07
0.09
0.10
0.00
0.00
0.01
0.03
0.06

14,000
193
-65
27.4
0.08
197
-63
26.8
0.08
201
-61
26.2
0.08
192
-63
27.6
0.08
200
-54
26.5
0.08
208
-55
25.5
0.07

15,000
194
-63
27.5
0.09
199
-61
26.9
0.09
203
-59
26.3
0.09
194
-61
27.7
0.09
202
-56
26.6
0.09
209
-50
25.6
0.09

LEGEND
BF Bypass Factor
RH
Relative Humidity
Edb Entering Dry Bulb
SHC Sensible Heat Cap. (1000 Btuh)
Ewb Entering Wet Bulb
TC
Total Cap. (1000 Btuh) Gross
kW Compressor Motor Power
Input
NOTES:
1. The SHC is based on 75 F edb temperature of air entering evaporator coil. For edb temperatures other than 75 F, adjust SHC by
multiplying the correction factor and the cfm and then adding or
subtracting the value from the SHC.
2. Interpolation is permissible.
3. Correction Factor = 1.10 x (1 BF) x (edb 75).
4. Cooling capacities are gross and do not include deduction for
indoor fan motor heat.
5. Capacity table includes impact of outdoor fan staging at temperatures below 75 F.

54

6. SHC values provided reflect maximum reheat values with 100%


gas bypass. Negative SHC value indicates that the air entering
the coil is being heated at 100% gas bypass. The P Series innovative modulating valve system will reduce the gas bypass as
required to meet the supply air setpoint with minimal change in
latent capacity. The space will NOT be overheated and the unit
will provide variable SHC to meet the space load.

COOLING CAPACITIES (cont)


48/50P2,P3,P4,P5040 (40 TON) STANDARD CAPACITY COIL STANDARD MODE
Evaporator Air Quantity Cfm
Temp (F)
8,000
10,000
12,000
Air Entering
Condenser
Evaporator Air Ewb (F)
(Edb)
75
72
67
62
57
75
72
67
62
57
75
72
67
TC
477 458 420 383 348 501 483 443 405 367 519 497 458
SHC
195 210 246 282 317 206 220 271 313 348 207 237 290
75
kW
24.8 24.5 24.0 23.6 23.3 25.3 24.9 24.3 23.9 23.5 25.7 25.2 24.6
BF
0.00 0.00 0.00 0.33 0.26 0.00 0.00 0.39 0.31 0.31 0.00 0.00 0.36
TC
467 447 409 371 338 490 471 431 393 356 507 485 446
SHC
191 206 241 277 311 202 218 266 308 340 203 233 286
85
kW
27.5 27.3 26.9 26.6 26.3 28.0 27.7 27.1 26.8 26.5 28.3 27.9 27.4
BF
0.00 0.00 0.00 0.31 0.26 0.00 0.00 0.36 0.30 0.31 0.00 0.00 0.35
TC
455 435 397 359 326 479 457 418 379 341 494 470 431
SHC
186 199 237 271 304 190 214 261 302 334 194 229 280
95
kW
30.7 30.6 30.2 30.0 29.8 31.2 30.9 30.5 30.2 29.9 31.5 31.1 30.7
BF
0.00 0.00 0.00 0.30 0.26 0.00 0.00 0.34 0.29 0.30 0.00 0.00 0.34
TC
440 420 382 346 312 463 440 401 364 330 477 453 413
SHC
180 192 231 265 295 184 209 254 295 321 189 223 269
105
kW
34.4 34.4 34.1 34.2 34.5 34.9 34.7 34.4 34.2 34.3 35.1 34.9 34.6
BF
0.00 0.00 0.42 0.29 0.27 0.00 0.00 0.32 0.29 0.33 0.00 0.44 0.33
TC
422 406 365 330 297 443 420 383 347 315 456 434 395
SHC
174 187 224 257 283 178 203 247 288 312 183 217 265
115
kW
38.7 38.4 38.9 39.4 40.3 39.1 39.0 38.9 39.2 39.8 39.3 39.2 39.1
BF
0.00 0.00 0.34 0.28 0.29 0.00 0.00 0.31 0.28 0.34 0.00 0.39 0.32

14,000
62
420
339
24.1
0.32
407
334
27.0
0.31
393
328
30.4
0.31
377
321
34.3
0.30
359
314
39.1
0.29

57
383
371
23.5
0.37
370
367
26.6
0.35
360
356
30.0
0.37
347
347
34.4
0.38
334
334
39.6
0.40

75
533
210
26.0
0.00
520
205
28.6
0.00
504
203
31.7
0.00
486
199
35.3
0.00
466
193
39.5
0.00

72
508
249
25.5
0.22
497
246
28.2
0.44
482
241
31.3
0.42
464
235
35.1
0.39
443
229
39.4
0.37

67
469
307
24.8
0.36
457
302
27.6
0.36
441
296
30.9
0.35
424
289
34.8
0.35
404
282
39.1
0.34

62
431
364
24.2
0.33
419
358
27.1
0.33
404
352
30.5
0.32
387
345
34.3
0.32
368
336
39.2
0.32

57
397
397
23.9
0.39
388
387
26.8
0.41
377
377
30.3
0.42
364
364
34.4
0.44
350
350
39.4
0.46

48/50P2,P3,P4,P5040 (40 TON) STANDARD CAPACITY COIL STANDARD MODE (cont)


Evaporator Air Quantity Cfm
Temp (F)
16,000
18,000
20,000
Air Entering
Condenser
Evaporator Air Ewb (F)
(Edb)
75
72
67
62
57
75
72
67
62
57
75
72
67
62
57
TC
542 518 478 440 413 549 525 486 447 426 557 531 491 453 438
SHC
220 261 324 386 413 228 272 339 406 426 237 282 354 424 438
75
kW
26.2 25.7 24.9 24.4 24.0 26.4 25.8 25.1 24.5 24.2 26.5 25.9 25.2 24.6 24.4
BF
0.00 0.43 0.37 0.35 0.45 0.00 0.41 0.38 0.37 0.49 0.49 0.41 0.39 0.39 0.53
527 505 465 427 402 535 512 472 434 416 541 518 478 440 427
TC
SHC
216 257 319 380 402 223 268 334 401 416 232 277 350 415 427
85
kW
28.8 28.3 27.7 27.3 27.0 29.0 28.5 27.8 27.3 27.1 29.1 28.6 27.9 27.5 27.3
BF
0.00 0.41 0.37 0.35 0.46 0.26 0.41 0.38 0.36 0.50 0.48 0.41 0.39 0.39 0.54
TC
512 490 450 412 391 520 496 456 419 404 527 502 462 423 415
SHC
212 252 313 373 391 219 263 329 391 404 227 272 344 402 415
95
kW
31.8 31.5 31.0 30.6 30.4 32.1 31.6 31.1 30.7 30.5 32.2 31.8 31.2 30.8 30.7
BF
0.00 0.40 0.36 0.35 0.47 0.53 0.40 0.37 0.37 0.52 0.46 0.40 0.38 0.39 0.55
494 471 432 394 378 502 477 438 401 391 507 483 443 405 400
TC
SHC
208 246 306 365 378 215 258 322 378 391 222 267 337 395 400
105
kW
35.4 35.2 34.8 34.5 34.4 35.7 35.2 34.9 34.5 34.4 35.8 35.5 35.0 34.6 34.6
BF
0.50 0.38 0.35 0.35 0.49 0.46 0.37 0.37 0.38 0.53 0.44 0.39 0.38 0.40 0.57
TC
473 450 411 375 365 480 456 417 382 375 484 461 421 389 384
SHC
201 240 299 354 365 209 250 314 363 375 215 260 330 373 384
115
kW
39.7 39.6 39.1 39.3 39.0 39.9 39.7 39.2 39.3 39.3 40.0 39.7 39.2 39.0 39.3
BF
0.47 0.37 0.35 0.35 0.51 0.42 0.37 0.36 0.40 0.55 0.42 0.38 0.37 0.45 0.59
LEGEND
Where: hewb = Enthalpy of air entering evaporator coil.
3. SHC is based on 80 F edb temperature of air entering evaporator
48/50P3,P5 units only.
coil.
Below 80 F edb, subtract (corr factor x cfm) from SHC.
BF Bypass Factor
kW
Compressor Motor Power Input
Above 80 F edb, add (corr factor x cfm) to SHC.
Edb Entering Dry Bulb
SHC Sensible Heat Cap. (1000 Btuh)
Ewb Entering Wet Bulb
TC
Total Cap. (1000 Btuh) Gross
ENTERING AIR DRY-BULB TEMP (F)
NOTES:
79
78
77
76
75
under 75
1. Direct interpolation is permissible. Do not extrapolate.
BF
2. The following formulas may be used:
81
82
83
84
85
over 85
Correction Factor
sensible capacity (Btuh)
tldb = tedb
.05
1.04
2.09
3.14
4.18
5.22
1.10 x cfm
Use formula
.10
0.99
1.98
2.97
3.96
4.95
.20
0.88
1.76
2.64
3.52
4.40 shown below
Wet-bulb temperature corresponding to enthalpy of air
tlwb =
leaving evaporator coil (hlwb).
Interpolation is permissible.
Correction Factor = 1.10 x (1 BF) x (edb 80).
total capacity (Btuh)
hlwb = hewb
4. Cooling capacities are gross and do not include deduction for indoor
4.5 x cfm
fan motor heat.

55

Performance data (cont)


COOLING CAPACITIES (cont)
48/50P2,P3,P4,P5040 (40 TON) STANDARD CAPACITY COIL SUBCOOL MODE
Evaporator Air Quantity Cfm
Temp (F)
8,000
10,000
12,000
Air Entering
Condenser
Evaporator Air Ewb (F)
(Edb)
75
72
67
62
57
75
72
67
62
57
75
72
67
TC
453 431 395 358 329 479 450 418 379 340 498 473 433
SHC
162 177 207 247 288 175 185 233 275 313 178 201 252
75
24.6 24.2 23.5 22.9 23.5 25.1 24.5 23.9 23.3 22.7 25.5 25.0 24.2
kW
BF
0.00 0.00 0.00 0.12 0.30 0.00 0.00 0.14 0.37 0.34 0.00 0.00 0.14
TC
434 413 379 344 308 460 437 401 363 329 478 453 416
148 161 193 235 269 156 177 220 263 302 157 186 239
SHC
85
kW
27.1 26.7 26.1 25.5 25.1 27.6 27.1 26.5 25.8 25.4 28.0 27.5 26.7
BF
0.00 0.00 0.19 0.12 0.31 0.00 0.00 0.14 0.37 0.34 0.00 0.20 0.14
TC
416 396 362 325 294 439 418 384 357 316 456 445 397
SHC
134 146 180 220 257 141 163 206 261 290 142 177 224
95
kW
29.9 29.6 29.0 28.4 28.1 30.4 30.0 29.4 29.9 28.4 30.8 30.9 29.6
0.00 0.00 0.16 0.12 0.31 0.00 0.00 0.13 0.36 0.34 0.00 0.18 0.14
BF
TC
391 377 346 322 287 418 397 364 340 300 434 414 376
SHC
114 133 164 221 254 126 148 192 249 275 126 153 209
105
33.3 32.9 32.4 33.0 32.7 33.7 33.3 32.7 33.6 31.8 34.0 33.6 33.0
kW
BF
0.00 0.00 0.15 0.11 0.32 0.00 0.00 0.13 0.36 0.36 0.00 0.17 0.14
TC
374 360 325 305 261 395 374 342 309 283 409 389 354
SHC
103 123 154 209 226 108 132 176 222 259 110 136 194
115
kW
37.0 36.8 36.2 37.0 35.2 37.4 37.0 36.5 36.0 35.6 37.7 37.3 36.8
BF
0.00 0.00 0.13 0.11 0.37 0.00 0.18 0.12 0.35 0.37 0.00 0.16 0.13

62
393
300
23.5
0.36
377
288
26.1
0.36
373
289
30.0
0.35
353
273
34.0
0.36
320
245
36.2
0.35

57
363
342
23.1
0.37
349
329
25.6
0.38
332
312
28.6
0.40
316
296
32.0
0.41
299
280
35.9
0.42

48/50P2,P3,P4,P5040 (40 TON) STANDARD CAPACITY COIL SUBCOOL MODE (cont)


Evaporator Air Quantity Cfm
Temp (F)
16,000
18,000
Air Entering
Condenser
Evaporator Air Ewb (F)
(Edb)
75
72
67
62
57
75
72
67
62
57
75
72
TC
523 496 452 414 393 532 504 460 420 405 540 511
SHC
192 225 285 346 380 196 236 301 364 405 199 246
75
kW
26.0 25.5 24.6 23.9 24.6 26.2 25.6 24.8 24.0 24.9 26.4 25.8
BF
0.00 0.18 0.42 0.38 0.45 0.23 0.18 0.42 0.41 0.49 0.21 0.50
TC
500 474 434 397 368 508 482 442 416 378 515 489
SHC
175 209 271 332 368 179 220 278 356 378 182 230
85
kW
28.4 27.9 27.1 26.4 25.9 28.6 28.1 27.3 27.8 26.1 28.8 28.2
BF
0.25 0.17 0.41 0.38 0.45 0.21 0.17 0.42 0.40 0.47 0.20 0.49
TC
476 453 414 377 351 484 476 421 381 363 491 466
SHC
158 193 256 316 351 161 219 271 333 363 165 214
95
kW
31.2 30.7 30.0 29.3 28.9 31.4 31.9 30.1 29.4 29.1 31.6 31.0
BF
0.22 0.17 0.41 0.39 0.46 0.20 0.17 0.41 0.41 0.50 0.19 0.48
TC
452 430 392 358 335 459 437 389 362 346 466 459
SHC
141 177 240 301 335 144 187 245 315 346 148 213
105
kW
34.5 34.0 33.3 32.7 32.3 34.6 34.1 33.2 32.8 32.5 34.8 35.3
BF
0.20 0.16 0.41 0.40 0.46 0.19 0.16 0.41 0.42 0.51 0.19 0.47
TC
427 405 369 335 316 450 411 375 344 327 441 416
SHC
119 159 224 284 316 143 169 239 298 327 132 178
115
kW
38.1 37.7 37.1 36.5 36.2 39.2 37.8 37.2 36.7 36.4 38.5 38.0
BF
0.18 0.16 0.41 0.41 0.48 0.18 0.16 0.41 0.44 0.52 0.18 0.47

62
427
376
24.2
0.44
419
377
27.4
0.43
390
348
29.6
0.44
369
323
32.9
0.44
351
310
36.8
0.46

57
404
385
23.8
0.57
388
388
26.3
0.51
373
373
29.3
0.54
356
356
32.7
0.55
336
336
36.5
0.56

LEGEND
48/50P3,P5 units only.
BF Bypass Factor
kW
Compressor Motor Power Input
Edb Entering Dry Bulb
SHC Sensible Heat Cap. (1000 Btuh)
Ewb Entering Wet Bulb
TC
Total Cap. (1000 Btuh) Gross
NOTES:
1. The SHC is based on 80 F edb temperature of air entering evaporator coil. For edb temperatures other than 80 F, adjust SHC by
multiplying the correction factor and the cfm and then adding or
subtracting the value from the SHC.

56

14,000
75
513
183
25.8
0.00
490
167
28.2
0.00
467
151
31.0
0.00
444
134
34.3
0.00
418
117
37.9
0.20

72
486
212
25.3
0.18
465
197
27.7
0.17
459
197
31.5
0.17
422
166
33.8
0.16
398
149
37.5
0.15

67
455
281
25.6
0.43
426
255
26.9
0.42
406
241
29.8
0.42
385
225
33.1
0.41
362
209
36.9
0.41

62
406
326
23.8
0.36
388
311
26.3
0.37
360
287
29.0
0.37
345
277
33.1
0.36
329
266
36.4
0.37

57
377
362
23.3
0.42
361
347
25.8
0.43
345
330
28.8
0.44
328
314
32.2
0.45
309
296
36.1
0.46

20,000
67
466
316
24.9
0.42
434
288
27.2
0.42
441
300
31.6
0.42
395
260
33.4
0.42
380
252
37.3
0.42

2. Interpolation is permissible.
3. Correction Factor = 1.10 x (1 BF) x (edb 80).
4. Cooling capacities are gross and do not include deduction for
indoor fan motor heat.
5. SHC values provided are in subcooling mode with the gas bypass
valve closed and reflect the maximum SHC in subcooling mode.
The P Series innovative modulating valve system can reduce SHC
as needed to meet the supply air set point requirement with minimal change in latent capacity. This will provide variable SHC to
meet the space load.

COOLING CAPACITIES (cont)


48/50P2,P3,P4,P5040 (40 TON) STANDARD CAPACITY COIL HOT GAS REHEAT MODE
Air Entering Evaporator Ewb (F)
Temp (F)
75 Dry Bulb
75 Dry Bulb
Air Ent
62.5 Wet Bulb (50% RH)
65.3 Wet Bulb (60% RH)
Condenser
Air Entering Evaporator Cfm
(Edb)
8000 10,000 12,000
14,000
16,000
18,000
20,000
8000 10,000 12,000
14,000
16,000
TC
142
153
161
165
169
173
176
152
163
171
176
180
SHC
-12
1
12
23
34
45
55
-37
-37
-27
-19
-11
80
kW
26.0
25.8
25.9
26.3
26.3
26.2
26.2
26.5
26.1
26.1
26.5
26.4
BF
0.20
0.14
0.15
0.44
0.42
0.42
0.43
0.00
0.00
0.17
0.16
0.16
TC
145
156
164
168
173
176
179
155
166
174
179
184
SHC
-11
3
14
25
36
47
58
-36
-35
-25
-17
-9
75
kW
25.2
25.0
25.0
25.4
25.4
25.4
25.4
25.6
25.4
25.3
25.7
25.7
BF
0.00
0.15
0.15
0.44
0.42
0.42
0.43
0.00
0.00
0.17
0.16
0.16
TC
143
154
162
166
170
174
176
152
163
170
176
180
SHC
-11
2
13
24
35
47
55
-36
-36
-26
-18
-10
70
kW
25.8
25.6
25.7
26.1
26.1
26.1
26.1
26.6
26.5
26.4
26.4
26.4
BF
0.20
0.14
0.15
0.44
0.42
0.42
0.43
0.00
0.00
0.17
0.16
0.16
TC
148
159
167
172
176
180
182
157
169
177
182
186
SHC
-8
5
16
27
38
49
60
-33
-33
-23
-15
-7
60
kW
24.2
24.2
24.2
24.5
24.6
24.7
24.7
24.8
24.7
24.7
25.0
25.0
BF
0.00
0.15
0.15
0.44
0.42
0.42
0.43
0.00
0.00
0.17
0.17
0.17
TC
152
163
171
176
181
184
187
162
173
181
187
191
SHC
-5
8
19
30
40
51
62
-30
-31
-21
-12
-4
50
kW
22.9
22.9
23.1
23.3
23.4
23.4
23.5
23.6
23.7
23.8
23.9
24.0
BF
0.00
0.15
0.15
0.44
0.42
0.42
0.43
0.00
0.00
0.18
0.17
0.17
TC
155
167
175
181
186
189
193
165
177
186
193
197
SHC
-3
10
21
32
43
54
65
-29
-30
-19
-9
-2
40
kW
22.0
22.1
22.2
22.4
22.4
22.5
22.6
22.9
23.0
23.0
23.1
23.2
BF
0.00
0.16
0.15
0.44
0.42
0.42
0.43
0.00
0.00
0.19
0.17
0.17

18,000
184
-2
26.5
0.46
187
-1
25.7
0.46
184
-2
26.5
0.46
190
1
25.1
0.46
195
4
24.0
0.46
201
6
23.3
0.47

20,000
187
6
26.5
0.45
190
7
25.8
0.45
186
6
26.6
0.45
193
9
25.2
0.45
198
12
24.1
0.45
204
14
23.3
0.46

48/50P2,P3,P4,P5040 (40 TON) STANDARD CAPACITY COIL HOT GAS REHEAT MODE (cont)
Air Entering Evaporator Ewb (F)
Temp (F)
75 Dry Bulb
75 Dry Bulb
Air Ent
68 Wet Bulb (70% RH)
70.5 Wet Bulb (80% RH)
Condenser
Air Entering Evaporator Cfm
(Edb)
8000 10,000 12,000
14,000
16,000
18,000
20,000
8000 10,000 12,000
14,000
16,000
TC
160
172
180
186
191
194
197
169
180
189
196
200
SHC
-58
-65
-66
-63
-56
-50
-45
-84
-85
-87
-97
-93
80
kW
27.1
27.1
27.0
26.9
26.9
27.0
27.0
27.5
27.3
27.2
27.4
27.3
BF
0.00
0.00
0.00
0.21
0.19
0.18
0.18
0.00
0.00
0.00
0.00
0.00
TC
163
175
183
189
194
198
200
172
183
193
200
204
SHC
-56
-63
-64
-61
-54
-48
-43
-82
-83
-85
-95
-91
75
kW
26.3
26.3
26.2
26.2
26.2
26.2
26.3
26.7
26.5
26.5
26.7
26.6
BF
0.00
0.00
0.00
0.22
0.19
0.19
0.19
0.00
0.00
0.00
0.00
0.00
TC
162
172
180
185
190
193
196
170
180
189
195
199
SHC
-56
-64
-64
-62
-56
-49
-44
-83
-84
-86
-95
-92
70
kW
26.9
27.0
27.0
27.0
27.0
27.1
27.1
27.4
27.3
27.4
27.5
27.5
BF
0.00
0.00
0.00
0.21
0.19
0.18
0.18
0.00
0.00
0.00
0.00
0.00
TC
166
178
185
191
196
200
202
175
186
195
201
206
SHC
-54
-61
-62
-62
-52
-47
-41
-80
-80
-84
-93
-90
60
kW
25.5
25.6
25.6
25.7
25.7
25.7
25.8
26.0
26.0
26.1
26.3
26.4
BF
0.00
0.00
0.00
0.22
0.19
0.19
0.19
0.00
0.00
0.00
0.00
0.00
TC
171
184
191
197
202
206
209
178
191
201
208
213
SHC
-51
-59
-59
-59
-50
-44
-38
-76
-77
-81
-89
-87
50
kW
24.3
24.5
24.6
24.7
24.7
24.8
24.9
25.0
25.0
25.2
25.4
25.4
BF
0.00
0.00
0.00
0.00
0.20
0.19
0.19
0.00
0.00
0.00
0.00
0.00
TC
174
189
197
203
208
213
216
182
197
207
214
220
SHC
-44
-55
-57
-56
-47
-41
-36
-72
-75
-78
-86
-85
40
kW
23.3
23.7
23.8
23.9
23.9
24.0
24.1
24.1
24.2
24.4
24.6
24.7
BF
0.00
0.00
0.00
0.00
0.22
0.20
0.19
0.00
0.00
0.00
0.00
0.00

18,000
204
-96
27.4
0.00
208
-94
26.7
0.00
203
-95
27.6
0.26
209
-92
26.5
0.00
217
-89
25.5
0.00
224
-86
24.8
0.00

20,000
207
-92
27.4
0.23
211
-90
26.7
0.24
205
-92
27.7
0.22
212
-89
26.5
0.24
220
-86
25.6
0.00
227
-86
24.8
0.00

LEGEND
BF Bypass Factor
RH
Relative Humidity
Edb Entering Dry Bulb
SHC Sensible Heat Cap. (1000 Btuh)
Ewb Entering Wet Bulb
TC
Total Cap. (1000 Btuh) Gross
kW Compressor Motor Power
Input
NOTES:
1. The SHC is based on 75 F edb temperature of air entering evaporator coil. For edb temperatures other than 75 F, adjust SHC by
multiplying the correction factor and the cfm and then adding or
subtracting the value from the SHC.
2. Interpolation is permissible.

3. Correction Factor = 1.10 x (1 BF) x (edb 75).


4. Cooling capacities are gross and do not include deduction for
indoor fan motor heat.
5. Capacity table includes impact of outdoor fan staging at temperatures below 75 F.
6. SHC values provided reflect maximum reheat values with 100%
gas bypass. Negative SHC value indicates that the air entering
the coil is being heated at 100% gas bypass. The P Series innovative modulating valve system will reduce the gas bypass as
required to meet the supply air setpoint with minimal change in
latent capacity. The space will NOT be overheated and the unit
will provide variable SHC to meet the space load.

57

Performance data (cont)


COOLING CAPACITIES (cont)
48/50P2,P3,P4,P5040 (40 TON) HIGH-CAPACITY COIL STANDARD MODE
Evaporator Air Quantity Cfm
Temp (F)
8,000
10,000
12,000
Air Entering
Condenser
Evaporator Air Ewb (F)
(Edb)
75
72
67
62
57
75
72
67
62
57
75
72
67
TC
502 480 439 404 369 531 504 464 427 395 550 523 480
SHC
207 227 273 315 352 217 249 301 353 389 228 266 326
75
kW
25.5 25.0 24.2 23.5 23.1 26.1 25.5 24.6 24.0 23.5 26.4 25.9 25.0
BF
0.00 0.00 0.15 0.11 0.12 0.00 0.22 0.14 0.12 0.18 0.15 0.19 0.15
TC
490 469 432 397 360 518 493 456 419 386 536 511 472
SHC
202 224 270 312 346 211 245 297 349 382 223 262 322
85
kW
28.0 27.6 26.9 26.4 26.1 28.6 28.1 27.3 26.8 26.3 29.0 28.4 27.6
BF
0.00 0.00 0.15 0.11 0.12 0.00 0.21 0.14 0.12 0.19 0.13 0.18 0.15
TC
480 461 423 387 350 507 484 445 408 375 526 501 461
SHC
197 221 265 307 339 208 242 293 344 375 220 258 318
95
kW
31.1 30.7 30.3 30.0 29.9 31.7 31.2 30.6 30.3 30.1 32.1 31.6 31.0
BF
0.00 0.00 0.15 0.11 0.13 0.00 0.20 0.14 0.12 0.19 0.12 0.17 0.15
TC
470 448 409 372 336 495 471 431 393 363 512 485 445
SHC
193 217 259 300 329 203 237 287 337 363 216 253 312
105
kW
34.8 34.6 34.5 34.5 35.7 35.5 35.2 34.8 34.7 35.0 36.0 35.5 35.1
BF
0.00 0.12 0.14 0.10 0.14 0.00 0.18 0.13 0.11 0.22 0.11 0.16 0.14
TC
454 431 392 355 319 478 452 412 373 349 491 466 425
SHC
186 211 252 291 318 198 230 279 328 349 209 245 304
115
kW
39.5 39.6 40.1 41.4 44.0 40.4 40.1 40.3 41.3 42.6 40.8 40.6 40.5
BF
0.00 0.09 0.13 0.10 0.15 0.14 0.16 0.13 0.11 0.25 0.23 0.16 0.14

14,000
62
443
387
24.2
0.13
435
383
27.0
0.13
423
377
30.6
0.13
406
369
35.0
0.13
386
358
41.8
0.14

57
417
417
23.8
0.25
410
410
26.7
0.27
400
400
30.3
0.28
387
387
35.0
0.31
372
372
41.8
0.34

75
565
239
26.7
0.12
551
235
29.3
0.26
539
231
32.4
0.24
524
226
36.4
0.22
502
219
41.3
0.21

72
537
282
26.1
0.18
523
277
28.6
0.17
514
273
31.9
0.18
498
267
36.0
0.18
476
260
41.0
0.17

67
493
349
25.2
0.16
484
346
27.9
0.16
472
341
31.2
0.16
455
336
35.2
0.15
433
328
40.5
0.14

62
456
417
24.5
0.16
447
412
27.3
0.16
434
404
30.8
0.16
416
393
35.2
0.17
397
378
41.7
0.20

57
436
436
24.2
0.33
429
429
27.0
0.34
419
419
30.6
0.36
406
406
35.1
0.38
390
390
40.9
0.40

48/50P2,P3,P4,P5040 (40 TON) HIGH-CAPACITY COIL STANDARD MODE (cont)


Evaporator Air Quantity Cfm
Temp (F)
16,000
18,000
20,000
Air Entering
Condenser
Evaporator Air Ewb (F)
(Edb)
75
72
67
62
57
75
72
67
62
57
75
72
67
62
57
TC
577 548 503 463 453 585 556 511 474 466 593 563 517 481 479
SHC
250 296 372 438 453 259 309 393 458 466 268 322 413 475 479
75
kW
27.0 26.4 25.4 24.7 24.5 27.2 26.5 25.6 24.9 24.7 27.3 26.7 25.7 25.0 25.0
BF
0.24 0.19 0.17 0.19 0.39 0.23 0.21 0.19 0.23 0.44 0.23 0.22 0.20 0.27 0.49
TC
563 536 493 455 446 571 544 501 465 459 579 551 507 472 471
SHC
245 291 368 433 446 255 304 389 452 459 264 317 410 472 471
85
kW
29.5 29.0 28.1 27.4 27.3 29.7 29.1 28.3 27.7 27.5 29.9 29.3 28.4 27.7 27.7
BF
0.23 0.20 0.17 0.20 0.40 0.22 0.21 0.19 0.24 0.45 0.22 0.22 0.20 0.27 0.49
TC
550 524 481 444 436 559 532 487 453 449 566 538 494 461 461
SHC
241 287 363 421 436 251 300 388 441 449 260 313 404 461 461
95
kW
32.7 32.2 31.4 31.0 30.8 32.9 32.4 31.4 31.1 31.0 33.1 32.5 31.7 31.2 31.2
BF
0.22 0.19 0.17 0.22 0.42 0.22 0.20 0.16 0.26 0.46 0.22 0.21 0.20 0.29 0.51
TC
533 507 462 427 422 541 514 470 437 435 547 520 476 447 446
SHC
236 281 360 414 422 245 294 380 431 435 254 307 396 446 446
105
kW
36.7 36.3 35.3 35.4 35.0 37.0 36.5 35.6 35.2 35.3 37.2 36.6 35.9 35.5 35.5
BF
0.21 0.19 0.15 0.22 0.43 0.21 0.20 0.17 0.27 0.48 0.21 0.21 0.20 0.31 0.52
TC
511 484 441 407 405 517 491 447 418 417 523 496 452 428 428
SHC
229 273 350 401 405 238 286 371 416 417 245 299 392 428 428
115
kW
41.8 41.4 40.7 41.6 41.4 42.1 41.6 41.0 41.2 41.3 42.7 41.8 41.0 41.3 41.3
BF
0.20 0.19 0.16 0.23 0.46 0.20 0.20 0.17 0.29 0.50 0.22 0.21 0.18 0.34 0.54
Where: hewb = Enthalpy of air entering evaporator coil.
LEGEND
3. SHC is based on 80 F edb temperature of air entering evaporator
48/50P3,P5 units only.
coil.
Below 80 F edb, subtract (corr factor x cfm) from SHC.
BF Bypass Factor
kW
Compressor Motor Power Input
Above 80 F edb, add (corr factor x cfm) to SHC.
Edb Entering Dry Bulb
SHC Sensible Heat Cap. (1000 Btuh)
Ewb Entering Wet Bulb
TC
Total Cap. (1000 Btuh) Gross
ENTERING AIR DRY-BULB TEMP (F)
NOTES:
79
78
77
76
75
under 75
1. Direct interpolation is permissible. Do not extrapolate.
BF
2. The following formulas may be used:
81
82
83
84
85
over 85
Correction Factor
sensible capacity (Btuh)
tldb = tedb
.05
1.04
2.09
3.14
4.18
5.22
1.10 x cfm
Use formula
.10
0.99
1.98
2.97
3.96
4.95
.20
0.88
1.76
2.64
3.52
4.40 shown below
Wet-bulb temperature corresponding to enthalpy of air
tlwb =
leaving evaporator coil (hlwb).
Interpolation is permissible.
Correction Factor = 1.10 x (1 BF) x (edb 80).
total capacity (Btuh)
hlwb = hewb
4. Cooling capacities are gross and do not include deduction for indoor
4.5 x cfm
fan motor heat.

58

COOLING CAPACITIES (cont)


48/50P2,P3,P4,P5040 (40 TON) HIGH-CAPACITY COIL SUBCOOL MODE
Evaporator Air Quantity Cfm
Temp (F)
8,000
10,000
12,000
Air Entering
Condenser
Evaporator Air Ewb (F)
(Edb)
75
72
67
62
57
75
72
67
62
57
75
72
67
TC
445 418 373 335 300 479 451 403 363 337 495 467 424
SHC
133 154 191 234 273 148 174 224 275 322 152 190 252
75
24.9 24.4 23.5 22.8 22.3 25.6 25.0 24.0 23.3 22.8 25.8 25.3 24.4
kW
BF
0.00 0.00 0.06 0.13 0.12 0.00 0.08 0.17 0.13 0.17 0.12 0.08 0.16
TC
414 389 347 313 279 443 416 377 340 318 466 437 398
106 129 167 213 254 117 143 200 254 304 128 165 229
SHC
85
kW
27.2 26.6 25.8 25.2 24.7 27.7 27.2 26.4 25.7 25.2 28.2 27.6 26.7
BF
0.00 0.13 0.06 0.13 0.12 0.00 0.07 0.17 0.13 0.18 0.11 0.07 0.16
TC
384 361 322 290 261 412 387 351 317 299 433 407 372
SHC
80
104 144 193 236
90
118 177 234 285
99
138 206
95
kW
29.7 29.2 28.5 28.0 27.5 30.3 29.8 29.1 28.5 28.2 30.8 30.2 29.5
0.00 0.10 0.05 0.13 0.14 0.00 0.07 0.17 0.13 0.19 0.10 0.07 0.16
BF
355 333 295 265 239 380 356 323 292 279 401 376 343
TC
SHC
53
80
121 172 217
63
92
154 213 266
72
112 183
105
32.7 32.3 31.7 31.3 31.0 33.3 32.8 32.3 31.8 31.6 33.8 33.3 32.7
kW
BF
0.00 0.09 0.05 0.13 0.13 0.15 0.07 0.16 0.13 0.20 0.09 0.07 0.16
TC
324 303 266 239 220 346 323 294 264 259 365 343 313
SHC
27
56
99
151 199
35
65
131 192 248
44
85
159
115
kW
36.2 35.9 35.4 35.4 35.5 36.8 36.4 36.0 36.0 35.9 37.3 36.9 36.5
0.00 0.08 0.05 0.12 0.15 0.11 0.06 0.16 0.13 0.21 0.09 0.07 0.16
BF

62
385
314
23.7
0.14
362
293
26.0
0.14
338
273
28.9
0.14
312
251
32.2
0.14
284
229
36.3
0.15

57
358
352
23.2
0.24
339
332
25.6
0.25
318
311
28.5
0.26
300
293
31.9
0.25
276
269
36.1
0.27

48/50P2,P3,P4,P5040 (40 TON) HIGH-CAPACITY COIL SUBCOOL MODE (cont)


Evaporator Air Quantity Cfm
Temp (F)
16,000
18,000
Air Entering
Condenser
Evaporator Air Ewb (F)
(Edb)
75
72
67
62
57
75
72
67
62
57
75
TC
523 498 452 414 399 540 508 462 426 413 549
SHC
176 227 304 377 399 194 243 327 394 413 205
75
kW
26.4 25.9 24.9 24.2 23.9 26.8 26.1 25.1 24.4 24.2 27.0
BF
0.10 0.21 0.18 0.19 0.36 0.28 0.22 0.19 0.23 0.40 0.26
TC
493 466 426 393 378 504 477 435 407 396 513
SHC
152 200 281 356 378 164 217 304 379 396 174
85
kW
28.7 28.1 27.3 26.6 26.3 29.0 28.3 27.5 26.8 26.6 29.1
BF
0.09 0.21 0.18 0.20 0.37 0.27 0.22 0.19 0.24 0.42 0.26
TC
462 439 400 370 357 473 449 409 384 370 480
SHC
125 177 259 333 357 138 192 282 357 370 146
95
kW
31.4 30.8 30.0 29.4 29.1 31.6 31.0 30.2 29.7 29.4 31.7
BF
0.09 0.21 0.18 0.21 0.38 0.27 0.22 0.19 0.25 0.43 0.26
TC
428 408 371 346 335 439 417 380 361 348 449
SHC
97
151 235 311 335 110 167 259 335 348 122
105
kW
34.4 34.0 33.3 32.7 32.5 34.7 34.2 33.5 33.0 32.8 34.9
BF
0.09 0.21 0.18 0.22 0.39 0.26 0.21 0.19 0.26 0.44 0.26
TC
393 374 338 322 310 403 385 347 335 324 412
SHC
70
126 210 288 310
82
142 233 310 324
93
115
kW
38.1 37.6 37.0 36.7 36.5 38.4 37.9 37.3 36.9 36.7 38.6
BF
0.08 0.21 0.18 0.23 0.40 0.27 0.21 0.19 0.27 0.45 0.25

62
428
406
24.5
0.26
419
400
27.1
0.28
398
380
29.9
0.28
377
360
33.4
0.29
347
327
37.2
0.29

57
419
419
24.3
0.46
405
405
26.8
0.45
382
382
29.6
0.46
361
361
33.0
0.48
334
334
36.9
0.49

LEGEND
48/50P3,P5 units only.
BF Bypass Factor
kW
Compressor Motor Power Input
Edb Entering Dry Bulb
SHC Sensible Heat Cap. (1000 Btuh)
Ewb Entering Wet Bulb
TC
Total Cap. (1000 Btuh) Gross
NOTES:
1. The SHC is based on 80 F edb temperature of air entering evaporator coil. For edb temperatures other than 80 F, adjust SHC by
multiplying the correction factor and the cfm and then adding or
subtracting the value from the SHC.

14,000
75
518
170
26.4
0.10
482
139
28.5
0.10
449
111
31.1
0.09
416
84
34.1
0.09
381
56
37.7
0.08

72
486
211
25.7
0.22
453
183
27.9
0.22
424
158
30.5
0.22
393
132
33.6
0.21
358
105
37.3
0.21

67
440
279
24.7
0.17
414
256
27.0
0.17
388
234
29.8
0.17
358
210
33.0
0.17
329
187
36.8
0.17

62
401
348
23.9
0.16
378
328
26.3
0.16
354
307
29.1
0.17
331
284
32.4
0.18
300
255
36.4
0.18

57
382
381
23.6
0.30
362
361
26.0
0.31
339
339
28.8
0.30
318
317
32.2
0.31
295
295
36.3
0.34

20,000
72
516
257
26.3
0.22
485
232
28.5
0.22
454
205
31.2
0.22
422
179
34.3
0.22
390
155
38.1
0.22

67
471
350
25.3
0.20
444
327
27.6
0.20
417
305
30.4
0.20
388
281
33.6
0.20
354
255
37.5
0.20

2. Interpolation is permissible.
3. Correction Factor = 1.10 x (1 BF) x (edb 80).
4. Cooling capacities are gross and do not include deduction for
indoor fan motor heat.
5. SHC values provided are in subcooling mode with the gas bypass
valve closed and reflect the maximum SHC in subcooling mode.
The P Series innovative modulating valve system can reduce SHC
as needed to meet the supply air set point requirement with minimal change in latent capacity. This will provide variable SHC to
meet the space load.

59

Performance data (cont)


COOLING CAPACITIES (cont)
48/50P2,P3,P4,P5040 (40 TON) HIGH-CAPACITY COIL HOT GAS REHEAT MODE
Air Entering Evaporator Ewb (F)
Temp (F)
75 Dry Bulb
75 Dry Bulb
Air Ent
62.5 Wet Bulb (50% RH)
65.3 Wet Bulb (60% RH)
Condenser
Air Entering Evaporator Cfm
(Edb)
8000 10,000 12,000
14,000
16,000
18,000
20,000
8000 10,000 12,000
14,000
16,000
TC
157
168
176
181
186
189
192
165
177
185
191
196
SHC
11
25
40
56
72
88
104
-25
-15
-5
5
17
80
kW
24.6
24.8
24.9
25.1
25.2
25.3
25.4
25.5
25.6
25.7
25.9
26.0
BF
0.22
0.16
0.16
0.17
0.18
0.19
0.20
0.08
0.07
0.19
0.19
0.20
TC
158
169
177
183
187
191
194
167
179
187
193
197
SHC
12
26
41
57
73
89
105
-23
-14
-4
7
18
75
kW
24.0
24.2
24.3
24.5
24.6
24.7
24.8
24.9
25.0
25.2
25.3
25.4
BF
0.22
0.16
0.16
0.17
0.18
0.19
0.20
0.08
0.07
0.19
0.19
0.20
TC
156
167
175
180
184
189
191
165
176
184
190
195
SHC
11
26
41
56
72
90
105
-23
-14
-4
6
18
70
kW
24.8
25.0
25.3
25.4
25.6
25.7
25.8
25.7
26.0
26.2
26.3
26.5
BF
0.21
0.16
0.16
0.17
0.18
0.19
0.20
0.08
0.23
0.19
0.19
0.19
TC
160
171
178
184
188
192
195
168
180
188
194
198
SHC
14
28
43
59
75
92
108
-20
-11
-2
9
20
60
kW
23.6
23.9
24.1
24.3
24.4
24.6
24.7
24.6
24.8
25.0
25.2
25.4
BF
0.20
0.16
0.16
0.17
0.18
0.19
0.20
0.08
0.22
0.19
0.19
0.19
TC
163
175
183
189
193
196
199
172
184
193
199
203
SHC
17
31
46
62
78
94
111
-18
-8
1
12
24
50
kW
22.7
23.0
23.2
23.4
23.6
23.7
23.8
23.7
24.0
24.2
24.3
24.5
BF
0.20
0.16
0.16
0.17
0.18
0.19
0.20
0.09
0.22
0.19
0.19
0.19
TC
165
178
186
192
197
200
204
174
187
196
202
207
SHC
19
33
49
65
81
97
114
-16
-6
4
15
26
40
kW
22.0
22.3
22.5
22.7
22.9
23.0
23.1
23.0
23.2
23.4
23.6
23.8
BF
0.20
0.16
0.16
0.17
0.18
0.19
0.20
0.09
0.21
0.19
0.19
0.19

18,000
199
28
26.1
0.20
201
30
25.5
0.20
198
29
26.6
0.20
202
32
25.5
0.20
207
36
24.6
0.20
211
38
23.9
0.20

20,000
202
40
26.1
0.21
204
42
25.6
0.21
200
42
26.7
0.21
204
44
25.6
0.21
210
48
24.7
0.21
214
51
24.0
0.21

48/50P2,P3,P4,P5040 (40 TON) HIGH-CAPACITY COIL HOT GAS REHEAT MODE (cont)
Air Entering Evaporator Ewb (F)
Temp (F)
75 Dry Bulb
75 Dry Bulb
Air Ent
68 Wet Bulb (70% RH)
70.5 Wet Bulb (80% RH)
Condenser
Air Entering Evaporator Cfm
(Edb)
8000 10,000 12,000
14,000
16,000
18,000
20,000
8000 10,000 12,000
14,000
16,000
TC
174
186
195
201
206
209
212
182
195
204
210
215
SHC
-55
-56
-50
-43
-36
-29
-21
-83
-89
-92
-92
-86
80
kW
26.4
26.5
26.6
26.7
26.8
26.9
27.0
27.2
27.4
27.5
27.6
27.6
BF
0.00
0.09
0.08
0.24
0.22
0.23
0.23
0.00
0.00
0.00
0.12
0.10
TC
176
188
197
203
208
211
215
185
198
207
213
218
SHC
-54
-55
-48
-41
-34
-27
-19
-81
-88
-90
-90
-84
75
kW
25.8
26.0
26.1
26.2
26.3
26.4
26.4
26.6
26.8
27.0
27.1
27.1
BF
0.00
0.10
0.08
0.24
0.22
0.23
0.23
0.00
0.00
0.00
0.12
0.11
TC
173
185
193
200
204
208
211
180
193
202
208
213
SHC
-54
-55
-48
-42
-35
-28
-20
-82
-88
-90
-91
-85
70
kW
26.7
26.9
27.1
27.2
27.4
27.5
27.6
27.6
27.8
28.0
28.2
28.3
BF
0.00
0.09
0.08
0.23
0.22
0.23
0.23
0.00
0.00
0.00
0.12
0.10
TC
177
189
197
204
208
212
215
186
199
207
213
218
SHC
-52
-52
-45
-39
-31
-25
-17
-78
-85
-87
-86
-82
60
kW
25.6
25.9
26.0
26.2
26.3
26.4
26.5
26.5
26.8
27.0
27.1
27.2
BF
0.00
0.10
0.08
0.23
0.22
0.22
0.23
0.00
0.00
0.00
0.12
0.11
TC
181
194
202
209
214
218
221
188
203
212
219
224
SHC
-52
-49
-42
-36
-29
-21
-13
-76
-82
-84
-83
-78
50
kW
24.8
25.0
25.1
25.3
25.4
25.5
25.6
25.6
25.9
26.1
26.2
26.3
BF
0.00
0.11
0.09
0.23
0.22
0.23
0.23
0.00
0.00
0.00
0.13
0.11
TC
183
197
206
213
218
222
225
192
206
216
223
228
SHC
-52
-47
-40
-33
-26
-18
-10
-73
-80
-81
-80
-75
40
kW
24.1
24.3
24.4
24.6
24.7
24.8
24.9
24.8
25.2
25.4
25.5
25.6
BF
0.00
0.12
0.09
0.23
0.22
0.23
0.23
0.00
0.00
0.00
0.14
0.12

18,000
219
-82
27.7
0.31
222
-80
27.2
0.31
218
-81
28.4
0.29
222
-78
27.3
0.29
228
-74
26.4
0.29
233
-71
25.7
0.29

20,000
223
-78
27.8
0.28
225
-76
27.3
0.27
222
-77
28.5
0.27
225
-73
27.4
0.27
231
-70
26.5
0.27
236
-67
25.8
0.27

LEGEND
BF Bypass Factor
RH
Relative Humidity
Edb Entering Dry Bulb
SHC Sensible Heat Cap. (1000 Btuh)
Ewb Entering Wet Bulb
TC
Total Cap. (1000 Btuh) Gross
kW Compressor Motor Power
Input
NOTES:
1. The SHC is based on 75 F edb temperature of air entering evaporator coil. For edb temperatures other than 75 F, adjust SHC by
multiplying the correction factor and the cfm and then adding or
subtracting the value from the SHC.
2. Interpolation is permissible.
3. Correction Factor = 1.10 x (1 BF) x (edb 75).
4. Cooling capacities are gross and do not include deduction for
indoor fan motor heat.
5. Capacity table includes impact of outdoor fan staging at temperatures below 75 F.

60

6. SHC values provided reflect maximum reheat values with 100%


gas bypass. Negative SHC value indicates that the air entering
the coil is being heated at 100% gas bypass. The P Series innovative modulating valve system will reduce the gas bypass as
required to meet the supply air setpoint with minimal change in
latent capacity. The space will NOT be overheated and the unit
will provide variable SHC to meet the space load.

COOLING CAPACITIES (cont)


48/50P2,P3,P4,P5050 (50 TON) STANDARD CAPACITY COIL STANDARD MODE
Evaporator Air Quantity Cfm
Temp (F)
10,000
12,500
15,000
Air Entering
Condenser
Evaporator Air Ewb (F)
(Edb)
75
72
67
62
57
75
72
67
62
57
75
72
67
TC
633 606 558 512 466 665 635 587 541 494 690 656 607
SHC
260 281 338 389 436 273 303 369 431 480 277 323 398
75
kW
33.8 33.3 32.5 32.1 31.9 34.3 33.8 33.0 32.5 32.2 34.7 34.2 33.3
BF
0.00 0.00 0.09 0.18 0.15 0.00 0.00 0.23 0.19 0.21 0.00 0.13 0.23
TC
614 592 543 495 450 646 618 571 523 477 667 637 590
SHC
251 273 331 381 427 257 297 363 423 461 268 316 391
85
kW
37.4 37.0 36.4 36.2 36.0 38.0 37.5 36.8 36.5 36.0 38.4 37.8 37.1
BF
0.00 0.00 0.26 0.17 0.15 0.00 0.00 0.22 0.18 0.24 0.00 0.32 0.22
TC
598 573 525 476 428 628 600 551 502 458 646 618 570
SHC
245 268 323 371 413 251 291 355 413 458 262 310 383
95
kW
41.8 41.4 41.2 41.1 41.2 42.4 42.0 41.5 41.4 41.3 42.7 42.3 41.8
BF
0.00 0.00 0.23 0.16 0.16 0.00 0.14 0.21 0.18 0.24 0.00 0.29 0.21
TC
578 552 502 454 408 606 577 527 478 436 623 594 544
SHC
237 261 314 360 398 243 283 345 402 436 256 302 372
105
kW
47.1 46.9 46.8 47.2 48.7 47.6 47.4 47.2 47.3 48.2 47.9 47.6 47.5
BF
0.00 0.00 0.20 0.16 0.17 0.00 0.12 0.20 0.17 0.25 0.00 0.27 0.21
TC
553 526 477 429 382 580 549 500 451 416 595 566 516
SHC
227 253 303 349 379 234 273 334 390 416 248 292 361
115
kW
53.2 53.3 53.8 55.5 58.0 53.7 53.6 53.9 55.3 56.9 53.9 53.9 54.1
BF
0.00 0.00 0.18 0.15 0.20 0.00 0.27 0.19 0.17 0.28 0.16 0.25 0.20
48/50P2,P3,P4,P5050 (50 TON) STANDARD
CAPACITY COIL STANDARD MODE (cont)
Evaporator Air Quantity
Cfm
Temp (F)
Air Entering
20,000
Condenser
Evaporator Air Ewb (F)
(Edb)
75
72
67
62
57
TC
719 685 633 587 562
SHC
301 357 448 539 562
75
kW
35.2 34.7 33.8 33.2 32.9
BF
0.17 0.29 0.25 0.23 0.40
TC
693 662 616 568 547
SHC
293 350 441 529 547
85
kW
38.9 38.3 37.6 37.1 36.9
BF
0.15 0.28 0.24 0.24 0.41
TC
668 643 594 543 528
SHC
286 343 433 515 528
95
kW
43.2 42.8 42.2 41.9 41.8
BF
0.35 0.27 0.24 0.24 0.43
TC
645 618 568 519 507
SHC
279 335 423 498 507
105
kW
48.3 48.1 47.8 47.5 47.5
BF
0.32 0.26 0.24 0.26 0.45
TC
615 587 537 491 484
SHC
270 325 412 480 484
115
kW
54.2 54.3 54.1 55.0 55.1
BF
0.30 0.25 0.23 0.28 0.48

17,500
62
561
470
32.8
0.20
542
461
36.7
0.20
520
452
41.6
0.19
495
441
47.3
0.19
467
428
55.3
0.19

57
520
518
32.4
0.28
501
500
36.5
0.29
484
484
41.4
0.31
465
465
47.8
0.33
443
443
56.0
0.36

75
707
288
35.0
0.00
681
282
38.7
0.20
658
275
43.0
0.17
635
268
48.1
0.14
607
259
54.1
0.33

72
672
341
34.4
0.30
650
333
38.1
0.28
632
327
42.6
0.27
608
319
47.9
0.26
578
309
54.1
0.24

67
622
423
33.6
0.24
605
417
37.4
0.23
583
408
42.1
0.23
557
398
47.7
0.22
528
387
54.1
0.22

62
576
506
33.0
0.21
557
497
36.9
0.21
534
487
41.8
0.21
508
474
47.5
0.22
479
455
55.0
0.23

57
541
541
32.6
0.33
526
526
36.7
0.35
508
508
41.7
0.38
488
488
47.6
0.40
466
466
55.5
0.43

LEGEND
48/50P3,P5 units only.
BF Bypass Factor
kW
Compressor Motor Power Input
Edb Entering Dry Bulb
SHC Sensible Heat Cap. (1000 Btuh)
Ewb Entering Wet Bulb
TC
Total Cap. (1000 Btuh) Gross
NOTES:
1. Direct interpolation is permissible. Do not extrapolate.
2. The following formulas may be used:
sensible capacity (Btuh)
tldb = tedb
1.10 x cfm
tlwb =

Wet-bulb temperature corresponding to enthalpy of air


leaving evaporator coil (hlwb).

hlwb =

hewb

total capacity (Btuh)


4.5 x cfm

Where: hewb = Enthalpy of air entering evaporator coil.


3. SHC is based on 80 F edb temperature of air entering evaporator coil.
Below 80 F edb, subtract (corr factor x cfm) from SHC.
Above 80 F edb, add (corr factor x cfm) to SHC.

BF

79
81

.05
.10
.20

1.04
0.99
0.88

ENTERING AIR DRY-BULB TEMP (F)


78
77
76
75
under 75
82
83
84
85
over 85
Correction Factor
2.09
3.14
4.18
5.22
Use formula
1.98
2.97
3.96
4.95
shown below
1.76
2.64
3.52
4.40

Interpolation is permissible.
Correction Factor = 1.10 x (1 BF) x (edb 80).
4. Cooling capacities are gross and do not include deduction for indoor fan motor heat.

61

Performance data (cont)


COOLING CAPACITIES (cont)
48/50P2,P3,P4,P5050 (50 TON) STANDARD CAPACITY COIL SUBCOOL MODE
Evaporator Air Quantity Cfm
Temp (F)
10,000
12,500
15,000
Air Entering
Condenser
Evaporator Air Ewb (F)
(Edb)
75
72
67
62
57
75
72
67
62
57
75
72
67
TC
590 563 519 472 450 625 598 549 502 465 652 619 571
SHC
206 233 275 329 413 219 248 308 370 450 228 256 336
75
33.2 32.7 32.1 31.5 31.8 33.8 33.3 32.5 31.9 31.4 34.2 33.7 32.9
kW
BF
0.02 0.00 0.13 0.08 0.13 0.00 0.00 0.11 0.28 0.18 0.00 0.16 0.35
TC
565 538 493 450 429 598 572 525 479 445 620 590 545
184 213 256 312 397 194 228 290 353 431 206 234 317
SHC
85
kW
36.7 36.2 35.6 35.2 35.5 37.3 36.8 36.1 35.6 35.0 37.7 37.2 36.5
BF
0.00 0.00 0.11 0.08 0.14 0.00 0.00 0.10 0.27 0.19 0.00 0.15 0.34
TC
538 513 466 424 407 568 544 498 451 436 593 563 517
SHC
163 195 236 293 380 172 208 270 332 424 177 215 296
95
kW
40.8 40.4 39.9 39.5 40.4 41.4 41.0 40.4 39.9 40.6 41.9 41.4 40.8
0.00 0.00 0.10 0.28 0.14 0.00 0.00 0.10 0.26 0.21 0.00 0.13 0.33
BF
TC
507 483 439 398 383 537 511 469 423 398 559 533 486
SHC
140 174 216 274 360 148 177 250 311 388 154 196 275
105
45.6 45.3 44.9 45.0 46.4 46.2 45.9 45.4 45.3 45.3 46.7 46.3 45.8
kW
BF
0.00 0.00 0.09 0.26 0.15 0.00 0.15 0.09 0.26 0.22 0.00 0.13 0.33
TC
474 454 429 399 343 501 477 454 408 375 521 497 470
SHC
116 145 224 294 321 124 155 253 320 366 129 173 280
115
kW
51.1 51.0 51.3 52.7 52.2 51.7 51.5 51.6 52.1 52.3 52.1 51.9 51.9
BF
0.00 0.00 0.15 0.13 0.18 0.00 0.13 0.17 0.16 0.24 0.00 0.12 0.19

17,500
62
524
406
32.3
0.28
500
388
35.9
0.28
473
369
40.3
0.27
445
350
45.5
0.27
424
357
52.1
0.18

57
491
480
31.6
0.25
467
467
35.4
0.26
444
444
39.9
0.27
420
420
45.5
0.29
394
394
52.3
0.31

75
671
235
34.5
0.00
638
212
38.0
0.00
607
189
42.2
0.00
572
164
46.9
0.17
534
138
52.4
0.15

72
638
281
34.0
0.14
610
260
37.5
0.13
581
238
41.7
0.13
547
215
46.6
0.12
510
191
52.2
0.12

67
588
362
33.2
0.33
562
343
36.8
0.32
533
322
41.1
0.32
502
301
46.1
0.31
483
305
52.0
0.21

62
551
473
32.5
0.20
513
420
36.2
0.29
487
402
40.5
0.29
458
382
45.8
0.29
434
388
52.1
0.21

57
513
513
32.0
0.32
492
492
35.8
0.34
467
467
40.1
0.35
442
442
45.6
0.36
415
415
52.2
0.38

48/50P2,P3,P4,P5050 (50 TON) STANDARD


CAPACITY COIL SUBCOOL MODE (cont)
Evaporator Air Quantity
Cfm
Temp (F)
Air Entering
20,000
Condenser
Evaporator Air Ewb (F)
(Edb)
75
72
67
62
57
TC
684 650 599 562 531
SHC
241 296 383 503 531
75
kW
34.8 34.2 33.4 32.7 32.3
BF
0.22 0.14 0.33 0.22 0.37
TC
650 621 573 536 508
SHC
217 274 363 483 508
85
kW
38.3 37.7 36.9 36.3 36.0
BF
0.18 0.13 0.32 0.22 0.39
TC
618 591 543 497 484
SHC
194 251 342 427 484
95
kW
42.4 41.9 41.3 40.7 40.4
BF
0.17 0.13 0.32 0.30 0.40
TC
583 557 511 492 458
SHC
169 228 320 447 458
105
kW
47.2 46.8 46.2 46.2 45.6
BF
0.16 0.12 0.32 0.25 0.41
TC
544 519 492 448 430
SHC
142 203 326 406 430
115
kW
52.6 52.3 52.1 51.9 52.1
BF
0.14 0.12 0.22 0.26 0.43
LEGEND
48/50P3,P5 units only.
BF Bypass Factor
kW
Compressor Motor Power Input
Edb Entering Dry Bulb
SHC Sensible Heat Cap. (1000 Btuh)
Ewb Entering Wet Bulb
TC
Total Cap. (1000 Btuh) Gross
NOTES:
1. The SHC is based on 80 F edb temperature of air entering evaporator coil. For edb temperatures other than 80 F, adjust SHC by
multiplying the correction factor and the cfm and then adding or
subtracting the value from the SHC.

62

2. Interpolation is permissible.
3. Correction Factor = 1.10 x (1 BF) x (edb 80).
4. Cooling capacities are gross and do not include deduction for
indoor fan motor heat.
5. SHC values provided are in subcooling mode with the gas bypass
valve closed and reflect the maximum SHC in subcooling mode.
The P Series innovative modulating valve system can reduce SHC
as needed to meet the supply air set point requirement with minimal change in latent capacity. This will provide variable SHC to
meet the space load.

COOLING CAPACITIES (cont)


48/50P2,P3,P4,P5050 (50 TON) STANDARD CAPACITY COIL HOT GAS REHEAT MODE
Air Entering Evaporator Ewb (F)
Temp (F)
75 Dry Bulb
Air Ent
62.5 Wet Bulb (50% RH)
Condenser
Air Entering Evaporator Cfm
(Edb)
10,000
12,500
15,000
17,500
20,000
10,000
TC
192
207
217
224
230
205
SHC
-4
11
27
43
59
-42
80
kW
35.7
36.0
36.0
36.4
36.4
36.8
BF
0.12
0.10
0.35
0.33
0.33
0.00
TC
197
211
222
229
235
209
SHC
-1
14
30
45
62
-39
75
kW
34.5
34.9
34.8
35.2
35.2
35.6
BF
0.13
0.11
0.35
0.33
0.33
0.00
TC
197
211
222
229
234
208
SHC
-1
14
30
45
62
-39
70
kW
35.0
35.3
35.4
35.7
35.8
36.1
BF
0.13
0.11
0.35
0.33
0.33
0.00
TC
205
219
229
237
243
215
SHC
3
18
34
50
65
-35
60
kW
33.0
33.3
33.3
33.6
33.7
34.1
BF
0.15
0.11
0.35
0.33
0.33
0.00
TC
209
224
234
242
248
219
SHC
6
21
37
53
68
-38
50
kW
31.6
31.9
31.9
32.1
32.3
32.7
BF
0.17
0.11
0.35
0.33
0.33
0.00
TC
213
227
238
246
252
225
SHC
8
24
39
55
70
-36
40
kW
30.9
31.0
31.1
31.3
31.4
32.0
BF
0.00
0.12
0.35
0.33
0.33
0.00

48/50P2,P3,P4,P5050 (50 TON) STANDARD CAPACITY COIL HOT GAS REHEAT MODE (cont)
Air Entering Evaporator Ewb (F)
Temp (F)
75 Dry Bulb
Air Ent
62.5 Wet Bulb (50% RH)
Condenser
Air Entering Evaporator Cfm
(Edb)
10,000
12,500
15,000
17,500
20,000
10,000
TC
218
233
244
252
258
227
SHC
-72
-79
-77
-71
-62
-102
80
kW
37.2
37.3
37.2
37.3
37.3
37.7
BF
0.00
0.00
0.00
0.16
0.14
0.00
TC
222
237
248
256
262
231
SHC
-70
-77
-75
-69
-61
-100
75
kW
36.1
36.2
36.2
36.2
36.2
36.7
BF
0.00
0.00
0.00
0.16
0.15
0.00
TC
220
236
247
254
260
229
SHC
-70
-76
-78
-69
-61
-100
70
kW
36.7
36.6
36.8
37.0
37.1
37.3
BF
0.00
0.00
0.00
0.16
0.15
0.03
TC
225
241
253
261
267
235
SHC
-62
-73
-75
-66
-58
-96
60
kW
34.7
35.0
35.1
35.2
35.3
35.5
BF
0.00
0.00
0.00
0.17
0.15
0.02
TC
230
248
259
267
273
241
SHC
-59
-71
-70
-63
-54
-93
50
kW
33.3
33.7
33.8
33.9
34.0
34.2
BF
0.00
0.00
0.00
0.18
0.16
0.01
TC
235
254
264
273
279
246
SHC
-56
-68
-68
-60
-51
-91
40
kW
32.5
32.8
33.0
33.0
33.0
33.4
BF
0.00
0.00
0.00
0.20
0.16
0.00

LEGEND
BF Bypass Factor
RH
Relative Humidity
Edb Entering Dry Bulb
SHC Sensible Heat Cap. (1000 Btuh)
Ewb Entering Wet Bulb
TC
Total Cap. (1000 Btuh) Gross
kW Compressor Motor Power
Input
NOTES:
1. The SHC is based on 75 F edb temperature of air entering evaporator coil. For edb temperatures other than 75 F, adjust SHC by
multiplying the correction factor and the cfm and then adding or
subtracting the value from the SHC.
2. Interpolation is permissible.
3. Correction Factor = 1.10 x (1 BF) x (edb 75).
4. Cooling capacities are gross and do not include deduction for
indoor fan motor heat.

75 Dry Bulb
65.3 Wet Bulb (60% RH)
12,500
220
-38
36.8
0.15
225
-35
35.5
0.16
223
-36
36.2
0.16
230
-32
34.2
0.00
235
-29
32.8
0.00
240
-26
32.0
0.00

15,000
231
-25
36.6
0.13
235
-23
35.5
0.13
234
-23
36.1
0.13
241
-19
34.2
0.13
245
-17
32.9
0.14
251
-14
32.0
0.14

17,500
239
-13
36.6
0.12
243
-11
35.5
0.12
242
-11
36.2
0.12
249
-7
34.3
0.13
253
-5
33.0
0.13
259
-2
32.1
0.13

20,000
245
-1
36.7
0.37
250
1
35.6
0.37
248
1
36.3
0.37
255
5
34.4
0.37
260
7
33.1
0.37
266
10
32.2
0.37

17,500
264
-119
37.9
0.00
268
-118
36.9
0.00
265
-118
37.8
0.00
272
-115
36.1
0.00
281
-112
34.8
0.00
286
-108
33.8
0.00

20,000
270
-116
37.8
0.00
274
-114
36.9
0.00
271
-114
37.9
0.00
278
-111
36.1
0.00
287
-107
34.8
0.00
293
-109
33.9
0.00

75 Dry Bulb
65.3 Wet Bulb (60% RH)
12,500
244
-108
37.7
0.00
247
-106
36.7
0.00
246
-106
37.4
0.00
251
-103
35.7
0.00
258
-99
34.4
0.00
264
-96
33.5
0.00

15,000
256
-111
37.7
0.00
260
-109
36.7
0.00
257
-109
37.6
0.00
264
-106
35.8
0.00
272
-103
34.6
0.00
277
-100
33.6
0.00

5. Capacity table includes impact of outdoor fan staging at temperatures below 75 F.


6. SHC values provided reflect maximum reheat values with 100%
gas bypass. Negative SHC value indicates that the air entering
the coil is being heated at 100% gas bypass. The P Series innovative modulating valve system will reduce the gas bypass as
required to meet the supply air setpoint with minimal change in
latent capacity. The space will NOT be overheated and the unit
will provide variable SHC to meet the space load.

63

Performance data (cont)


COOLING CAPACITIES (cont)
48/50P2,P3,P4,P5050 (50 TON) HIGH-CAPACITY COIL STANDARD MODE
Evaporator Air Quantity Cfm
Temp (F)
10,000
12,500
15,000
Air Entering
Condenser
Evaporator Air Ewb (F)
(Edb)
75
72
67
62
57
75
72
67
62
57
75
72
67
TC
638 609 560 517 476 673 643 590 546 503 698 665 611
SHC
264 289 343 397 446 274 312 376 441 490 284 332 406
75
kW
33.7 33.3 32.4 31.7 31.3 34.3 33.8 32.9 32.2 31.6 34.8 34.2 33.3
BF
0.00 0.00 0.20 0.14 0.13 0.00 0.13 0.19 0.15 0.18 0.00 0.25 0.19
TC
622 595 549 505 461 654 624 578 533 489 678 646 598
SHC
256 280 338 391 437 266 305 371 435 481 277 326 400
85
kW
37.4 36.9 36.1 35.5 35.4 38.0 37.4 36.6 36.0 35.6 38.4 37.8 37.0
BF
0.00 0.00 0.19 0.14 0.13 0.00 0.12 0.18 0.15 0.19 0.00 0.23 0.19
TC
606 582 535 488 440 638 610 562 515 472 658 630 582
SHC
248 277 332 383 424 257 300 364 426 465 273 320 394
95
kW
41.6 41.3 40.7 40.5 40.4 42.3 41.9 41.3 40.9 40.5 42.7 42.3 41.6
BF
0.00 0.00 0.18 0.13 0.13 0.00 0.11 0.17 0.15 0.22 0.00 0.23 0.18
TC
591 564 515 467 423 621 591 541 492 452 641 611 560
SHC
242 271 323 372 407 253 294 355 416 451 267 313 384
105
kW
46.9 46.8 46.6 46.6 47.6 47.7 47.5 47.1 46.9 47.4 48.3 48.0 47.5
BF
0.00 0.00 0.16 0.13 0.17 0.00 0.23 0.17 0.14 0.23 0.16 0.21 0.18
TC
569 540 490 443 400 596 565 514 466 431 614 583 531
SHC
234 262 312 360 394 244 284 344 403 431 259 304 374
115
kW
53.4 53.5 54.2 55.9 59.3 54.2 54.1 54.4 55.9 57.2 54.9 54.6 54.7
BF
0.00 0.12 0.15 0.12 0.17 0.00 0.21 0.16 0.14 0.26 0.13 0.20 0.17

48/50P2,P3,P4,P5050 (50 TON) HIGHCAPACITY COIL STANDARD MODE (cont)


Evaporator Air Quantity
Cfm
Temp (F)
Air Entering
20,000
Condenser
Evaporator Air Ewb (F)
(Edb)
75
72
67
62
57
TC
730 695 639 593 572
SHC
311 368 460 549 572
75
kW
35.3 34.7 33.8 33.0 32.6
BF
0.31 0.24 0.21 0.21 0.39
TC
707 675 624 578 561
SHC
305 361 454 541 561
85
kW
39.0 38.4 37.5 36.8 36.5
BF
0.28 0.23 0.21 0.22 0.40
TC
690 658 606 558 545
SHC
299 356 450 524 545
95
kW
43.5 42.9 42.1 41.5 41.4
BF
0.27 0.23 0.20 0.23 0.42
TC
668 635 582 534 525
SHC
292 348 440 514 525
105
kW
49.1 48.6 47.8 47.7 47.4
BF
0.25 0.22 0.20 0.23 0.44
TC
638 606 553 507 502
SHC
283 337 428 496 502
115
kW
55.8 55.4 55.2 56.0 55.7
BF
0.24 0.22 0.20 0.25 0.46

17,500
62
566
481
32.5
0.17
552
475
36.3
0.16
534
466
41.3
0.16
510
455
47.2
0.16
479
442
55.7
0.16

57
527
526
31.9
0.25
515
515
35.9
0.26
500
500
41.0
0.28
481
481
47.3
0.31
459
459
56.4
0.34

75
715
298
35.1
0.16
695
292
38.8
0.14
677
287
43.2
0.31
656
280
48.7
0.28
627
271
55.4
0.25

72
677
351
34.5
0.22
661
345
38.1
0.22
646
339
42.7
0.21
625
331
48.3
0.21
595
321
55.1
0.21

67
627
434
33.5
0.20
613
428
37.2
0.20
596
421
41.9
0.19
573
412
47.7
0.19
542
402
54.6
0.18

62
581
518
32.8
0.18
567
511
36.6
0.19
548
502
41.6
0.19
523
488
47.5
0.19
493
470
55.8
0.20

LEGEND
48/50P3,P5 units only.
BF Bypass Factor
kW
Compressor Motor Power Input
Edb Entering Dry Bulb
SHC Sensible Heat Cap. (1000 Btuh)
Ewb Entering Wet Bulb
TC
Total Cap. (1000 Btuh) Gross
NOTES:
1. Direct interpolation is permissible. Do not extrapolate.
2. The following formulas may be used:
sensible capacity (Btuh)
tldb = tedb
1.10 x cfm
tlwb =

Wet-bulb temperature corresponding to enthalpy of air


leaving evaporator coil (hlwb).

hlwb =

hewb

total capacity (Btuh)


4.5 x cfm

Where: hewb = Enthalpy of air entering evaporator coil.


3. SHC is based on 80 F edb temperature of air entering evaporator coil.
Below 80 F edb, subtract (corr factor x cfm) from SHC.
Above 80 F edb, add (corr factor x cfm) to SHC.

BF

79
81

.05
.10
.20

1.04
0.99
0.88

ENTERING AIR DRY-BULB TEMP (F)


78
77
76
75
under 75
82
83
84
85
over 85
Correction Factor
2.09
3.14
4.18
5.22
Use formula
1.98
2.97
3.96
4.95
shown below
1.76
2.64
3.52
4.40

Interpolation is permissible.
Correction Factor = 1.10 x (1 BF) x (edb 80).
4. Cooling capacities are gross and do not include deduction for indoor fan motor heat.

64

57
552
552
32.3
0.32
540
540
36.2
0.34
525
525
41.2
0.36
505
505
47.3
0.38
483
483
56.0
0.41

COOLING CAPACITIES (cont)


48/50P2,P3,P4,P5050 (50 TON) HIGH-CAPACITY COIL SUBCOOL MODE
Evaporator Air Quantity Cfm
Temp (F)
10,000
12,500
15,000
Air Entering
Condenser
Evaporator Air Ewb (F)
(Edb)
75
72
67
62
57
75
72
67
62
57
75
72
67
TC
589 555 500 454 407 633 597 538 489 452 673 619 563
SHC
191 216 261 316 365 209 238 301 366 427 241 260 335
75
33.4 32.8 32.0 31.2 30.5 34.2 33.6 32.5 31.7 31.1 35.1 33.9 33.0
kW
BF
0.00 0.00 0.07 0.16 0.13 0.00 0.11 0.24 0.16 0.18 0.00 0.10 0.21
TC
552 523 468 445 408 592 557 506 470 436 618 581 531
160 190 233 300 371 175 205 275 345 424 192 228 309
SHC
85
kW
36.7 36.1 35.2 34.7 34.3 37.4 36.8 35.8 35.1 34.6 37.9 37.2 36.3
BF
0.00 0.00 0.07 0.07 0.08 0.00 0.10 0.23 0.09 0.13 0.00 0.09 0.21
TC
514 485 436 418 382 551 510 475 441 417 575 543 499
SHC
128 159 206 279 350 142 162 249 323 406 158 198 282
95
kW
40.5 39.9 39.1 38.9 38.5 41.2 40.5 39.8 39.3 38.9 41.7 41.1 40.3
0.00 0.00 0.07 0.07 0.08 0.00 0.09 0.22 0.08 0.14 0.15 0.09 0.20
BF
477 450 402 387 365 511 473 440 408 363 537 504 464
TC
SHC
97
130 179 255 334 110 131 222 298 354 121 166 255
105
44.9 44.5 43.9 43.9 43.6 45.7 45.1 44.6 44.3 43.8 46.3 45.7 45.1
kW
BF
0.00 0.00 0.06 0.07 0.11 0.00 0.09 0.21 0.08 0.16 0.13 0.08 0.20
TC
438 412 365 353 340 469 430 402 372 333 493 461 424
SHC
64
100 151 230 314
77
99
194 271 326
87
134 226
115
kW
50.1 49.9 49.6 50.5 51.4 50.9 50.4 50.3 50.9 50.6 51.5 51.1 50.8
0.00 0.10 0.06 0.07 0.11 0.00 0.08 0.21 0.08 0.18 0.11 0.08 0.20
BF

17,500
62
515
411
32.1
0.18
488
390
35.5
0.10
457
365
39.7
0.10
423
339
44.7
0.10
387
312
51.0
0.11

57
482
468
31.5
0.24
460
460
35.0
0.20
435
435
39.2
0.22
405
405
44.2
0.24
381
381
50.7
0.26

75
697
251
35.4
0.14
640
201
38.3
0.13
597
166
42.2
0.12
555
133
46.7
0.11
511
99
52.0
0.10

72
653
297
34.6
0.30
601
252
37.6
0.29
564
221
41.5
0.28
525
191
46.2
0.27
482
159
51.5
0.26

67
583
367
33.3
0.21
550
340
36.6
0.21
518
314
40.7
0.21
482
286
45.5
0.20
441
256
51.1
0.20

62
534
452
32.4
0.19
502
432
35.8
0.12
470
405
39.9
0.13
436
378
44.8
0.13
400
345
50.2
0.15

57
509
509
32.0
0.28
483
483
35.4
0.29
453
453
39.5
0.30
425
425
44.5
0.31
398
398
50.7
0.33

48/50P2,P3,P4,P5050 (50 TON) HIGHCAPACITY COIL SUBCOOL MODE (cont)


Evaporator Air Quantity
Cfm
Temp (F)
Air Entering
20,000
Condenser
Evaporator Air Ewb (F)
(Edb)
75
72
67
62
57
TC
707 650 597 548 527
SHC
262 298 395 487 527
75
kW
35.6 34.3 33.5 32.7 32.3
BF
0.12 0.26 0.22 0.22 0.35
TC
650 616 564 517 506
SHC
211 271 369 473 506
85
kW
38.5 37.9 36.9 36.1 35.8
BF
0.12 0.26 0.21 0.15 0.35
TC
611 579 532 500 471
SHC
181 242 342 458 471
95
kW
42.5 41.8 40.9 40.2 39.8
BF
0.11 0.25 0.21 0.16 0.36
TC
570 539 496 446 442
SHC
148 211 315 411 442
105
kW
47.1 46.5 45.8 44.9 44.8
BF
0.11 0.25 0.21 0.16 0.38
TC
524 495 454 411 403
SHC
115 178 285 378 403
115
kW
52.4 51.8 51.4 50.6 50.6
BF
0.10 0.25 0.21 0.18 0.39
LEGEND
48/50P3,P5 units only.
BF Bypass Factor
kW
Compressor Motor Power Input
Edb Entering Dry Bulb
SHC Sensible Heat Cap. (1000 Btuh)
Ewb Entering Wet Bulb
TC
Total Cap. (1000 Btuh) Gross
NOTES:
1. The SHC is based on 80 F edb temperature of air entering evaporator coil. For edb temperatures other than 80 F, adjust SHC by
multiplying the correction factor and the cfm and then adding or
subtracting the value from the SHC.

2. Interpolation is permissible.
3. Correction Factor = 1.10 x (1 BF) x (edb 80).
4. Cooling capacities are gross and do not include deduction for
indoor fan motor heat.
5. SHC values provided are in subcooling mode with the gas bypass
valve closed and reflect the maximum SHC in subcooling mode.
The P Series innovative modulating valve system can reduce SHC
as needed to meet the supply air set point requirement with minimal change in latent capacity. This will provide variable SHC to
meet the space load.

65

Performance data (cont)


COOLING CAPACITIES (cont)
48/50P2,P3,P4,P5050 (50 TON) HIGH-CAPACITY COIL HOT GAS REHEAT MODE
Air Entering Evaporator Ewb (F)
Temp (F)
75 Dry Bulb
Air Ent
62.5 Wet Bulb (50% RH)
Condenser
Air Entering Evaporator Cfm
(Edb)
10,000
12,500
15,000
17,500
20,000
10,000
TC
203
217
226
233
238
212
SHC
11
27
44
62
82
-37
80
kW
34.3
34.6
34.8
35.0
35.1
35.5
BF
0.07
0.22
0.21
0.21
0.22
0.11
TC
205
219
229
237
242
215
SHC
13
28
46
64
81
-34
75
kW
33.4
33.7
33.9
34.1
34.3
34.6
BF
0.07
0.22
0.21
0.21
0.23
0.12
TC
204
218
228
235
240
214
SHC
13
28
46
64
81
-34
70
kW
34.0
34.4
34.7
34.9
35.2
35.2
BF
0.07
0.22
0.21
0.21
0.22
0.12
TC
209
223
233
240
245
220
SHC
16
31
49
67
84
-30
60
kW
32.5
32.8
33.1
33.3
33.6
33.8
BF
0.08
0.22
0.21
0.21
0.22
0.00
TC
214
229
239
246
252
225
SHC
19
35
52
71
91
-26
50
kW
31.4
31.7
32.0
32.2
32.3
32.6
BF
0.08
0.22
0.21
0.21
0.21
0.00
TC
218
232
243
250
256
228
SHC
22
37
55
73
94
-24
40
kW
30.8
31.0
31.2
31.4
31.6
32.0
BF
0.08
0.22
0.21
0.21
0.21
0.00

48/50P2,P3,P4,P5050 (50 TON) HIGH-CAPACITY COIL HOT GAS REHEAT MODE (cont)
Air Entering Evaporator Ewb (F)
Temp (F)
75 Dry Bulb
Air Ent
68 Wet Bulb (70% RH)
Condenser
Air Entering Evaporator Cfm
(Edb)
10,000
12,500
15,000
17,500
20,000
10,000
TC
223
238
249
257
263
233
SHC
-72
-75
-68
-60
-51
-104
80
kW
36.4
36.8
36.9
37.0
37.1
37.4
BF
0.00
0.15
0.11
0.11
0.28
0.00
TC
227
242
253
261
267
237
SHC
-70
-73
-66
-57
-50
-102
75
kW
35.6
35.9
36.0
36.1
36.3
36.6
BF
0.00
0.00
0.11
0.11
0.29
0.00
TC
225
239
249
257
263
234
SHC
-71
-73
-66
-58
-49
-103
70
kW
36.3
36.8
36.9
37.1
37.2
37.3
BF
0.00
0.16
0.11
0.11
0.27
0.00
TC
232
246
257
265
271
241
SHC
-68
-69
-62
-53
-45
-98
60
kW
34.8
35.2
35.3
35.5
35.6
35.8
BF
0.00
0.00
0.12
0.11
0.28
0.00
TC
236
251
263
271
278
246
SHC
-62
-68
-58
-50
-42
-94
50
kW
33.6
34.1
34.2
34.3
34.4
34.6
BF
0.00
0.00
0.12
0.11
0.28
0.00
TC
238
254
266
274
280
248
SHC
-61
-65
-57
-47
-39
-92
40
kW
32.9
33.3
33.3
33.4
33.5
33.8
BF
0.00
0.00
0.13
0.31
0.28
0.00

LEGEND
BF Bypass Factor
RH
Relative Humidity
Edb Entering Dry Bulb
SHC Sensible Heat Cap. (1000 Btuh)
Ewb Entering Wet Bulb
TC
Total Cap. (1000 Btuh) Gross
kW Compressor Motor Power
Input
NOTES:
1. The SHC is based on 75 F edb temperature of air entering evaporator coil. For edb temperatures other than 75 F, adjust SHC by
multiplying the correction factor and the cfm and then adding or
subtracting the value from the SHC.
2. Interpolation is permissible.
3. Correction Factor = 1.10 x (1 BF) x (edb 75).
4. Cooling capacities are gross and do not include deduction for
indoor fan motor heat.
5. Capacity table includes impact of outdoor fan staging at temperatures below 75 F.

66

75 Dry Bulb
65.3 Wet Bulb (60% RH)
12,500
228
-24
35.6
0.09
230
-22
34.8
0.09
229
-22
35.5
0.09
234
-19
33.9
0.10
240
-15
32.8
0.10
244
-12
32.1
0.10

15,000
238
-12
35.8
0.26
240
-11
34.9
0.26
239
-11
35.7
0.26
245
-7
34.2
0.26
251
-3
33.0
0.25
254
-1
32.2
0.25

17,500
245
1
35.9
0.24
248
2
35.1
0.24
246
2
36.0
0.24
252
6
34.4
0.24
259
9
33.2
0.24
262
12
32.4
0.24

20,000
249
15
36.0
0.24
254
15
35.2
0.24
252
15
36.1
0.24
258
19
34.6
0.24
265
23
33.4
0.24
268
26
32.5
0.24

17,500
270
-116
38.0
0.18
274
-113
37.1
0.00
269
-117
38.3
0.18
277
-113
36.6
0.00
283
-110
35.3
0.00
286
-107
34.4
0.00

20,000
276
-113
38.1
0.13
280
-112
37.3
0.14
275
-112
38.3
0.14
283
-108
36.8
0.14
292
-105
35.3
0.15
292
-103
34.4
0.16

75 Dry Bulb
70.5 Wet Bulb (80% RH)
12,500
250
-113
37.7
0.00
254
-111
36.8
0.00
250
-111
37.8
0.00
257
-105
36.1
0.00
262
-101
34.9
0.00
264
-99
34.1
0.00

15,000
262
-113
37.8
0.00
266
-111
37.0
0.00
261
-111
38.0
0.00
270
-107
36.4
0.00
275
-111
35.2
0.00
277
-109
34.3
0.00

6. SHC values provided reflect maximum reheat values with 100%


gas bypass. Negative SHC value indicates that the air entering
the coil is being heated at 100% gas bypass. The P Series innovative modulating valve system will reduce the gas bypass as
required to meet the supply air setpoint with minimal change in
latent capacity. The space will NOT be overheated and the unit
will provide variable SHC to meet the space load.

COOLING CAPACITIES (cont)


48/50P2,P3,P4,P5055 (55 TON) STANDARD CAPACITY COIL STANDARD MODE
Evaporator Air Quantity Cfm
Temp (F)
11,000
13,750
16,500
Air Entering
Condenser
Evaporator Air Ewb (F)
(Edb)
75
72
67
62
57
75
72
67
62
57
75
72
67
TC
685 654 604 558 510 722 686 636 588 538 744 709 656
SHC
281 311 375 434 486 292 338 412 485 525 307 361 446
75
kW
37.2 36.5 35.5 34.8 34.6 37.9 37.2 36.1 35.3 34.6 38.4 37.6 36.5
BF
0.00 0.00 0.15 0.11 0.11 0.00 0.24 0.14 0.12 0.18 0.00 0.19 0.15
TC
663 636 588 540 491 697 665 618 570 519 717 687 638
SHC
271 304 368 425 474 281 330 405 476 506 299 352 438
85
kW
41.0 40.5 39.7 39.3 39.2 41.8 41.1 40.3 39.8 39.1 42.3 41.6 40.7
BF
0.00 0.00 0.15 0.11 0.11 0.00 0.21 0.14 0.12 0.19 0.13 0.19 0.15
TC
646 619 570 520 466 676 647 598 547 504 694 667 617
SHC
264 298 359 415 451 276 323 396 466 504 292 346 430
95
kW
45.7 45.3 44.9 44.7 45.6 46.4 45.9 45.4 45.2 45.2 46.8 46.4 45.8
BF
0.00 0.00 0.14 0.11 0.12 0.00 0.19 0.13 0.11 0.21 0.11 0.18 0.14
TC
626 597 546 495 443 654 624 572 522 485 671 642 590
SHC
256 290 349 404 443 269 315 386 454 485 284 337 419
105
kW
51.3 51.2 51.1 52.1 54.4 51.9 51.7 51.6 52.0 53.0 52.4 52.2 51.9
BF
0.00 0.10 0.13 0.10 0.13 0.00 0.18 0.13 0.11 0.24 0.26 0.17 0.14

TC
643 612 561
602 570 519 468
626 595 544 492
SHC

275 326 407


243 280 337 390
261 305 374 440
115
kW
58.1 58.2 59.6 62.5 58.5 58.6 59.7 62.3 58.9 59.0 59.8
BF
0.00 0.22 0.12 0.10 0.12 0.16 0.12 0.11 0.23 0.16 0.14

19,250
62
609
531
35.7
0.13
589
522
40.1
0.13
566
505
45.5
0.13
539
497
52.5
0.14
508
481
62.2
0.14

57
572
572
35.2
0.25
556
556
39.7
0.28
537
537
45.2
0.30
516
516
52.5
0.33
494
494
61.0
0.36

75
761
322
38.8
0.29
732
313
42.6
0.26
708
306
47.1
0.23
686
299
52.8
0.22
657
289
59.5
0.20

72
726
381
38.0
0.19
702
373
41.9
0.18
681
366
46.7
0.18
655
357
52.5
0.17
625
347
59.3
0.16

67
672
477
36.9
0.16
653
470
41.0
0.16
631
461
46.1
0.16
604
451
52.2
0.15
573
439
59.9
0.15

62
625
572
36.1
0.15
604
562
40.5
0.16
580
549
45.9
0.16
552
533
52.5
0.17
521
513
61.3
0.19

57
598
598
35.6
0.33
582
582
40.0
0.35
563
563
45.4
0.37
542
542
51.9
0.39
517
517
61.1
0.42

48/50P2,P3,P4,P5055 (55 TON) STANDARD CAPACITY COIL STANDARD


MODE (cont)
Evaporator Air Quantity Cfm
Temp (F)
22,000
24,750
Air Entering
Condenser
Evaporator Air Ewb (F)
(Edb)
75
72
67
62
57
75
72
67
62
57
TC
773 738 684 636 620 785 748 693 642 638
SHC
335 401 508 607 620 348 419 536 627 638
75
kW
39.1 38.3 37.1 36.3 35.9 39.3 38.5 37.3 36.3 36.3
BF
0.25 0.19 0.17 0.18 0.39 0.24 0.20 0.18 0.23 0.45
TC
745 712 664 615 604 755 721 673 623 621
SHC
326 392 500 594 604 339 411 529 614 621
85
kW
42.9 42.2 41.3 40.6 40.2 43.2 42.3 41.5 40.6 40.6
BF
0.23 0.19 0.17 0.19 0.41 0.23 0.19 0.18 0.23 0.46
TC
722 691 642 592 585 732 701 650 602 602
SHC
319 385 491 579 585 331 402 520 595 602
95
kW
47.5 46.9 46.3 45.9 45.6 47.8 47.2 46.5 45.8 45.9
BF
0.22 0.18 0.17 0.20 0.43 0.22 0.20 0.18 0.25 0.48
TC
697 664 614 565 562 706 674 622 578 578
SHC
311 377 481 555 562 324 393 509 572 578
105
kW
53.1 52.6 52.4 51.9 52.0 53.4 53.0 52.6 52.1 52.1
BF
0.21 0.17 0.17 0.23 0.45 0.21 0.19 0.18 0.28 0.50
TC
666 633 582 539 536 674 640 590 554 553
SHC
302 365 469 532 536 314 383 497 550 553
115
kW
59.8 59.1 59.9 60.4 60.8 60.0 59.2 60.0 60.4 60.5
BF
0.20 0.17 0.16 0.26 0.48 0.20 0.18 0.18 0.32 0.52
3. SHC is based on 80 F edb temperature of air entering evaporator
LEGEND
coil.
48/50P3,P5 units only.
Below 80 F edb, subtract (corr factor x cfm) from SHC.
Above 80 F edb, add (corr factor x cfm) to SHC.
BF Bypass Factor
kW
Compressor Motor Power Input
Edb Entering Dry Bulb
SHC Sensible Heat Cap. (1000 Btuh)
ENTERING AIR DRY-BULB TEMP (F)
Ewb Entering Wet Bulb
TC
Total Cap. (1000 Btuh) Gross
79
78
77
76
75
under 75
NOTES:
BF
1. Direct interpolation is permissible. Do not extrapolate.
81
82
83
84
85
over 85
2. The following formulas may be used:
Correction Factor
sensible capacity (Btuh)
.05
1.04
2.09
3.14
4.18
5.22
tldb = tedb
Use formula
.10
0.99
1.98
2.97
3.96
4.95
1.10 x cfm
.20
0.88
1.76
2.64
3.52
4.40 shown below
tlwb = Wet-bulb temperature corresponding to enthalpy of air
leaving evaporator coil (hlwb).
Interpolation is permissible.
Correction Factor = 1.10 x (1 BF) x (edb 80).
total capacity (Btuh)
hlwb = hewb
4.
Cooling
capacities are gross and do not include deduction for indoor
4.5 x cfm
fan motor heat.
Where: hewb = Enthalpy of air entering evaporator coil.

67

Performance data (cont)


COOLING CAPACITIES (cont)
48/50P2,P3,P4,P5055 (55 TON) STANDARD CAPACITY COIL SUBCOOL MODE
Evaporator Air Quantity Cfm
Temp (F)
11,000
13,750
16,500
Air Entering
Condenser
Evaporator Air Ewb (F)
(Edb)
75
72
67
62
57
75
72
67
62
57
75
72
67
TC
648 613 562 501 464 681 647 598 541 494 704 668 615
SHC
206 244 311 364 434 221 269 354 424 487 236 290 383
75
41.9 41.3 40.5 39.7 39.2 42.5 41.9 41.2 40.2 39.6 43.0 42.3 41.4
kW
BF
0.03 0.08 0.08 0.07 0.08 0.12 0.10 0.09 0.09 0.14 0.14 0.12 0.12
TC
573 588 536 488 443 652 619 567 516 472 672 639 586
139 226 292 357 416 200 249 329 407 466 213 269 361
SHC
85
kW
44.8 45.1 44.3 43.7 43.0 46.2 45.6 44.8 44.1 43.4 46.6 46.0 45.1
BF
0.04 0.08 0.08 0.07 0.09 0.12 0.10 0.09 0.09 0.15 0.14 0.13 0.12
TC
591 560 510 463 422 621 515 538 490 455 640 533 558
SHC
165 206 273 338 403 178 154 309 388 455 191 172 342
95
kW
50.0 49.5 48.8 48.1 47.7 50.5 48.6 49.2 48.5 48.4 50.9 48.9 49.4
0.05 0.08 0.08 0.07 0.10 0.12 0.10 0.09 0.09 0.16 0.14 0.13 0.12
BF
TC
560 529 481 436 395 588 557 508 462 424 606 576 526
SHC
143 185 253 319 374 156 205 288 368 424 167 225 320
105
55.0 54.5 53.8 53.6 53.3 55.5 54.9 54.1 53.6 53.3 55.8 55.2 54.4
kW
BF
0.05 0.08 0.08 0.08 0.12 0.12 0.10 0.10 0.09 0.18 0.14 0.13 0.12
TC
526 497 451 408 371 552 523 476 432 398 569 540 493
SHC
121 163 232 299 352 132 183 266 347 398 143 201 298
115
kW
60.7 60.3 60.0 60.1 60.0 61.0 60.5 60.0 59.8 59.8 61.4 60.8 60.1
BF
0.05 0.08 0.08 0.08 0.14 0.12 0.10 0.10 0.10 0.20 0.14 0.13 0.12

19,250
62
561
471
40.5
0.11
537
453
44.3
0.12
509
433
48.7
0.12
479
411
53.7
0.12
448
389
59.8
0.12

57
523
523
40.0
0.23
500
500
43.8
0.24
476
476
48.2
0.26
451
451
53.5
0.27
424
424
59.7
0.29

75
719
248
43.3
0.16
687
225
46.9
0.16
652
200
51.1
0.16
623
183
56.2
0.16
584
157
61.7
0.16

72
684
310
42.6
0.15
654
289
46.3
0.15
623
267
50.6
0.15
589
243
55.5
0.15
552
219
61.0
0.15

67
630
415
41.6
0.14
602
394
45.3
0.14
572
373
49.7
0.14
539
351
54.6
0.14
505
328
60.2
0.14

62
578
515
40.8
0.14
551
495
44.5
0.14
522
473
48.9
0.14
491
450
53.8
0.15
460
422
59.7
0.17

57
549
549
40.3
0.31
525
525
44.2
0.32
500
500
48.6
0.33
474
474
53.6
0.35
457
457
60.4
0.37

48/50P2,P3,P4,P5055 (55 TON) STANDARD CAPACITY COIL SUBCOOL


MODE (cont)
Evaporator Air Quantity Cfm
Temp (F)
22,000
24,750
Air Entering
Condenser
Evaporator Air Ewb (F)
(Edb)
75
72
67
62
57
75
72
67
62
57
TC
732 699 641 589 571 742 709 651 598 597
SHC
260 332 445 553 571 272 350 474 584 597
75
kW
43.5 43.0 41.9 41.0 40.7 43.8 43.2 42.1 41.1 41.3
BF
0.18 0.16 0.15 0.17 0.37 0.20 0.18 0.17 0.20 0.43
TC
698 666 554 561 555 707 677 621 571 564
SHC
237 307 366 531 555 248 327 453 560 564
85
kW
47.2 46.5 44.5 44.7 44.9 47.4 46.8 45.7 44.8 44.8
BF
0.18 0.17 0.15 0.17 0.39 0.20 0.18 0.17 0.21 0.44
TC
665 634 582 532 530 674 642 591 543 545
SHC
214 285 403 508 530 224 302 431 531 545
95
kW
51.4 50.8 49.8 49.0 49.4 51.6 51.0 50.0 49.2 49.5
BF
0.18 0.17 0.15 0.18 0.40 0.20 0.18 0.17 0.23 0.45
TC
633 599 549 503 502 638 607 557 514 518
SHC
193 261 380 476 502 200 278 408 504 518
105
kW
56.4 55.7 54.8 54.0 54.4 56.4 55.8 54.9 54.1 54.6
BF
0.18 0.17 0.16 0.20 0.41 0.20 0.18 0.17 0.24 0.46
TC
591 562 514 473 463 599 569 522 482 488
SHC
164 237 357 449 463 174 253 384 475 488
115
kW
61.8 61.2 60.3 59.7 59.7 62.0 61.3 60.4 59.8 60.3
BF
0.18 0.17 0.16 0.22 0.43 0.20 0.18 0.17 0.26 0.48
LEGEND
48/50P3,P5 units only.
BF Bypass Factor
kW
Compressor Motor Power Input
Edb Entering Dry Bulb
SHC Sensible Heat Cap. (1000 Btuh)
Ewb Entering Wet Bulb
TC
Total Cap. (1000 Btuh) Gross
NOTES:
1. The SHC is based on 80 F edb temperature of air entering evaporator coil. For edb temperatures other than 80 F, adjust SHC by
multiplying the correction factor and the cfm and then adding or
subtracting the value from the SHC.

68

2. Interpolation is permissible.
3. Correction Factor = 1.10 x (1 BF) x (edb 80).
4. Cooling capacities are gross and do not include deduction for
indoor fan motor heat.
5. SHC values provided are in subcooling mode with the gas bypass
valve closed and reflect the maximum SHC in subcooling mode.
The P Series innovative modulating valve system can reduce SHC
as needed to meet the supply air set point requirement with minimal change in latent capacity. This will provide variable SHC to
meet the space load.

COOLING CAPACITIES (cont)


48/50P2,P3,P4,P5055 (55 TON) STANDARD CAPACITY COIL HOT GAS REHEAT MODE
Air Entering Evaporator Ewb (F)
Temp (F)
75 Dry Bulb
75 Dry Bulb
Air Ent
62.5 Wet Bulb (50% RH)
65.3 Wet Bulb (60% RH)
Condenser
Air Entering Evaporator Cfm
(Edb)
11,000
13,750
16,500
19,250
22,000
24,750
11,000
13,750
16,500
19,250
22,000
TC
225
242
252
260
266
270
238
256
267
275
281
SHC
24
46
69
92
115
138
-25
-11
4
20
37
80
kW
42.8
42.4
42.3
42.2
42.2
42.2
43.4
43.0
42.8
42.7
42.7
BF
0.08
0.09
0.12
0.13
0.15
0.17
0.08
0.10
0.12
0.14
0.16
TC
230
247
258
266
272
276
244
261
273
281
286
SHC
27
49
72
94
118
141
-22
-8
7
23
39
75
kW
41.4
41.0
40.8
40.8
40.8
40.8
42.0
41.6
41.5
41.4
41.4
BF
0.08
0.09
0.11
0.13
0.15
0.17
0.08
0.10
0.12
0.14
0.16
TC
230
246
256
264
269
273
243
259
270
277
283
SHC
27
49
71
94
117
140
-22
-9
6
22
38
70
kW
42.0
41.8
41.7
41.7
41.7
41.7
42.8
42.5
42.4
42.4
42.4
BF
0.08
0.09
0.12
0.13
0.15
0.17
0.08
0.10
0.12
0.14
0.16
TC
240
256
266
274
279
284
253
269
280
287
293
SHC
32
54
76
99
122
144
-17
-4
11
27
43
60
kW
39.5
39.3
39.3
39.3
39.3
39.4
40.3
40.1
40.0
40.1
40.1
BF
0.07
0.09
0.11
0.13
0.15
0.17
0.07
0.10
0.12
0.14
0.16
TC
248
265
275
283
289
293
261
278
289
296
302
SHC
37
59
81
103
126
149
-12
1
16
31
47
50
kW
37.3
37.2
37.3
37.4
37.4
37.5
38.2
38.1
38.1
38.2
38.3
BF
0.07
0.09
0.11
0.13
0.15
0.17
0.07
0.10
0.12
0.14
0.16
TC
255
272
283
292
298
304
268
286
298
307
314
SHC
42
63
85
108
125
154
-8
5
20
36
52
40
kW
35.5
35.6
35.7
35.8
36.0
36.1
36.4
36.5
36.6
36.7
36.9
BF
0.07
0.09
0.11
0.13
0.15
0.17
0.07
0.10
0.12
0.14
0.16

24,750
285
54
42.7
0.17
291
56
41.4
0.17
287
55
42.4
0.17
297
60
40.1
0.17
307
60
38.4
0.17
319
69
37.0
0.17

48/50P2,P3,P4,P5055 (55 TON) STANDARD CAPACITY COIL HOT GAS REHEAT MODE (cont)
Air Entering Evaporator Ewb (F)
Temp (F)
75 Dry Bulb
75 Dry Bulb
Air Ent
68 Wet Bulb (70% RH)
70.5 Wet Bulb (80% RH)
Condenser
Air Entering Evaporator Cfm
(Edb)
11,000
13,750
16,500
19,250
22,000
24,750
11,000
13,750
16,500
19,250
22,000
TC
252
270
281
289
295
300
265
283
294
302
309
SHC
-72
-67
-59
-49
-39
-29
-117
-119
-117
-114
-110
80
kW
44.1
43.6
43.4
43.3
43.3
43.3
44.8
44.3
44.2
44.0
44.0
BF
0.07
0.10
0.12
0.15
0.16
0.18
0.00
0.11
0.14
0.16
0.18
TC
258
275
286
295
301
305
270
288
300
308
314
SHC
-70
-64
-56
-47
-37
-26
-115
-116
-115
-111
-107
75
kW
42.7
42.3
42.1
42.0
42.1
42.0
43.5
43.1
42.9
42.8
42.8
BF
0.07
0.10
0.12
0.15
0.16
0.18
0.00
0.11
0.14
0.16
0.18
TC
256
272
283
291
296
301
268
285
296
303
309
SHC
-70
-64
-57
-48
-38
-27
-115
-117
-115
-112
-108
70
kW
43.6
43.2
43.2
43.2
43.2
43.2
44.4
44.1
44.1
44.0
44.0
BF
0.07
0.10
0.12
0.15
0.16
0.18
0.00
0.11
0.14
0.16
0.18
TC
265
282
293
301
307
311
277
295
306
314
320
SHC
-65
-59
-52
-43
-33
-23
-110
-112
-110
-108
-103
60
kW
41.1
40.9
40.9
40.9
40.9
41.0
42.0
41.8
41.8
41.7
41.8
BF
0.07
0.10
0.12
0.15
0.16
0.18
0.00
0.12
0.14
0.16
0.18
TC
274
291
302
310
317
322
286
303
315
324
331
SHC
-60
-55
-47
-39
-29
-22
-106
-107
-106
-103
-99
50
kW
39.1
39.0
39.0
39.1
39.2
39.3
40.0
39.9
40.0
40.0
40.1
BF
0.07
0.10
0.12
0.14
0.16
0.18
0.00
0.11
0.14
0.16
0.18
TC
281
300
312
322
329
335
294
313
327
337
344
SHC
-56
-51
-43
-33
-23
-13
-102
-103
-101
-98
-94
40
kW
37.4
37.4
37.6
37.7
37.7
37.8
38.3
38.4
38.5
38.5
38.6
BF
0.07
0.10
0.12
0.14
0.16
0.18
0.00
0.12
0.14
0.16
0.18

24,750
313
-105
44.0
0.20
319
-102
42.8
0.20
314
-103
44.0
0.20
324
-99
41.8
0.20
336
-94
40.1
0.20
350
-89
38.7
0.20

LEGEND
BF Bypass Factor
RH
Relative Humidity
Edb Entering Dry Bulb
SHC Sensible Heat Cap. (1000 Btuh)
Ewb Entering Wet Bulb
TC
Total Cap. (1000 Btuh) Gross
kW Compressor Motor Power
Input

6. SHC values provided reflect maximum reheat values with 100%


gas bypass. Negative SHC value indicates that the air entering
the coil is being heated at 100% gas bypass. The P Series innovative modulating valve system will reduce the gas bypass as
required to meet the supply air setpoint with minimal change in
latent capacity. The space will NOT be overheated and the unit
will provide variable SHC to meet the space load.

NOTES:
1. The SHC is based on 75 F edb temperature of air entering evaporator coil. For edb temperatures other than 75 F, adjust SHC by
multiplying the correction factor and the cfm and then adding or
subtracting the value from the SHC.
2. Interpolation is permissible.
3. Correction Factor = 1.10 x (1 BF) x (edb 75).
4. Cooling capacities are gross and do not include deduction for
indoor fan motor heat.
5. Capacity table includes impact of outdoor fan staging at temperatures below 75 F.

69

Performance data (cont)


COOLING CAPACITIES (cont)
48/50P2,P3,P4,P5055 (55 TON) HIGH-CAPACITY COIL STANDARD MODE
Evaporator Air Quantity Cfm
Temp (F)
11,000
13,750
16,500
Air Entering
Condenser
Evaporator Air Ewb (F)
(Edb)
75
72
67
62
57
75
72
67
62
57
75
72
67
TC
693 657 606 556 513 731 694 639 586 542 757 719 661
SHC
285 318 379 438 494 299 346 419 490 542 318 369 454
75
kW
37.2 36.5 35.4 34.4 33.6 38.0 37.2 36.1 35.0 34.2 38.5 37.7 36.5
BF
0.00 0.08 0.12 0.09 0.09 0.00 0.15 0.11 0.09 0.15 0.08 0.15 0.12
TC
675 641 591 544 501 709 674 623 573 532 735 699 645
SHC
277 312 372 432 486 292 339 412 484 532 311 361 447
85
kW
41.1 40.4 39.3 38.5 37.9 41.9 41.1 40.0 39.0 38.3 42.4 41.6 40.5
BF
0.00 0.08 0.11 0.08 0.09 0.00 0.14 0.11 0.09 0.17 0.21 0.15 0.12
TC
659 627 578 530 487 692 659 608 558 519 719 682 628
SHC
271 306 367 425 480 287 333 405 476 519 305 355 440
95
kW
45.7 45.1 44.3 43.5 43.4 46.5 45.9 44.9 44.1 43.5 47.4 46.5 45.5
BF
0.00 0.06 0.11 0.08 0.11 0.11 0.13 0.11 0.10 0.19 0.19 0.14 0.12
TC
641 610 558 507 463 674 639 586 534 503 696 659 605
SHC
264 299 358 415 458 281 325 396 467 503 298 347 431
105
kW
51.6 51.1 50.6 49.7 50.7 52.9 51.9 51.3 50.2 49.3 54.0 52.9 51.9
BF
0.00 0.18 0.10 0.07 0.12 0.09 0.12 0.10 0.08 0.21 0.17 0.14 0.11
TC
615 581 528 476 436 644 609 554 502 475 663 627 572
SHC
252 289 345 400 433 271 314 383 450 475 287 335 418
115
kW
60.1 59.8 59.8 58.7 60.6 62.3 61.0 60.6 61.0 60.4 64.3 62.2 61.4
BF
0.00 0.14 0.09 0.07 0.16 0.20 0.12 0.10 0.09 0.26 0.15 0.13 0.11

19,250
62
609
539
35.5
0.11
596
532
39.6
0.11
576
525
44.5
0.10
555
509
51.2
0.12
519
494
61.3
0.12

57
575
575
34.9
0.25
565
565
38.9
0.27
551
551
44.1
0.28
533
533
50.7
0.31
505
505
60.6
0.34

75
776
334
38.8
0.18
757
327
42.9
0.17
737
321
48.0
0.17
711
312
54.8
0.15

72
737
390
38.1
0.16
717
383
42.0
0.15
699
376
47.0
0.15
674
367
53.5
0.15
641
356
63.6
0.14

67
678
488
36.9
0.13
661
481
40.9
0.13
644
474
45.9
0.13
619
464
52.3
0.13
585
451
61.9
0.13

62
625
581
35.8
0.13
609
575
39.8
0.13
592
561
44.9
0.15
568
548
51.4
0.15
537
523
60.8
0.18

57
602
602
35.4
0.33
591
591
39.5
0.34
577
577
44.6
0.36
558
558
51.1
0.38
529
529
61.1
0.41

48/50P2,P3,P4,P5055 (55 TON) HIGH-CAPACITY COIL STANDARD MODE


(cont)
Evaporator Air Quantity Cfm
Temp (F)
22,000
24,750
Air Entering
Condenser
Evaporator Air Ewb (F)
(Edb)
75
72
67
62
57
75
72
67
62
57
TC
791 751 691 637 625 805 762 702 650 644
SHC
348 410 520 614 625 359 429 550 639 644
75
kW
39.1 38.3 37.2 36.1 35.8 39.4 38.6 37.4 36.4 36.2
BF
0.17 0.16 0.14 0.17 0.39 0.20 0.17 0.15 0.22 0.44
TC
771 730 673 621 612 787 743 684 634 632
SHC
341 403 512 606 612 354 422 543 620 632
85
kW
43.2 42.4 41.2 40.1 39.9 43.7 42.7 41.4 40.4 40.3
BF
0.17 0.16 0.14 0.17 0.40 0.19 0.18 0.15 0.24 0.45
TC
753 713 655 606 598 764 723 665 617 616
SHC
333 396 505 589 598 346 416 536 610 616
95
kW
48.8 47.6 46.2 45.2 45.0 49.3 47.8 46.5 45.3 45.4
BF
0.18 0.17 0.14 0.20 0.42 0.19 0.17 0.15 0.25 0.47
TC
724 686 630 584 578 733 696 638 596 596
SHC
324 387 495 570 578 336 406 525 596 596
105
kW
56.4 54.1 52.7 51.4 51.6 57.1 54.8 52.9 52.0 51.9
BF
0.18 0.16 0.14 0.22 0.44 0.18 0.17 0.15 0.26 0.48

TC
652 595 551 550

603 570 567


SHC

375 482 548 550

511 561 567


115
kW
65.0 62.3 61.3 61.4
63.1 61.2 61.7
BF
0.16 0.14 0.24 0.46
0.16 0.31 0.51
LEGEND
3. SHC is based on 80 F edb temperature of air entering evaporator
coil.
48/50P3,P5 units only.
Below 80 F edb, subtract (corr factor x cfm) from SHC.
Above 80 F edb, add (corr factor x cfm) to SHC.
BF Bypass Factor
kW
Compressor Motor Power Input
Edb Entering Dry Bulb
SHC Sensible Heat Cap. (1000 Btuh)
Ewb Entering Wet Bulb
TC
Total Cap. (1000 Btuh) Gross
ENTERING AIR DRY-BULB TEMP (F)
79
78
77
76
75
under 75
NOTES:
BF
1. Direct interpolation is permissible. Do not extrapolate.
81
82
83
84
85
over 85
2. The following formulas may be used:
Correction Factor
sensible capacity (Btuh)
.05
1.04
2.09
3.14
4.18
5.22
tldb = tedb
Use formula
.10
0.99
1.98
2.97
3.96
4.95
1.10 x cfm
.20
0.88
1.76
2.64
3.52
4.40 shown below
tlwb = Wet-bulb temperature corresponding to enthalpy of air
leaving evaporator coil (hlwb).
Interpolation is permissible.
Correction Factor = 1.10 x (1 BF) x (edb 80).
total capacity (Btuh)
hlwb = hewb
4.
Cooling
capacities are gross and do not include deduction for indoor
4.5 x cfm
fan motor heat.
Where: hewb = Enthalpy of air entering evaporator coil.

70

COOLING CAPACITIES (cont)


48/50P2,P3,P4,P5055 (55 TON) HIGH-CAPACITY COIL SUBCOOL MODE
Evaporator Air Quantity Cfm
Temp (F)
11,000
13,750
16,500
Air Entering
Condenser
Evaporator Air Ewb (F)
(Edb)
75
72
67
62
57
75
72
67
62
57
75
72
67
TC
639 598 533 481 441 678 632 569 510 476 704 658 588
SHC
174 211 270 338 411 194 237 316 392 467 213 263 350
75
42.0 41.3 40.2 39.3 38.7 42.8 42.0 40.9 39.9 39.2 43.3 42.5 41.2
kW
BF
0.03 0.02 0.02 0.02 0.03 0.05 0.03 0.02 0.03 0.09 0.06 0.04 0.04
TC
591 553 497 449 415 618 577 534 473 446 663 616 552
133 172 241 311 387 143 189 286 360 438 182 231 322
SHC
85
kW
45.4 44.7 43.7 43.0 42.5 46.0 45.2 44.3 43.3 42.8 46.7 45.9 44.7
BF
0.02 0.02 0.02 0.02 0.03 0.05 0.03 0.02 0.03 0.10 0.06 0.04 0.04
TC
563 525 469 415 395 595 552 493 436 416 618 573 510
SHC
113 151 219 283 371 128 172 253 330 410 144 195 288
95
kW
49.6 48.9 47.9 47.3 46.9 50.2 49.4 48.3 47.5 47.2 50.7 49.8 48.6
0.02 0.02 0.02 0.02 0.06 0.05 0.03 0.02 0.03 0.11 0.06 0.04 0.04
BF
511 476 423 380 364 554 512 454 407 389 577 514 457
TC
SHC
70
111 181 256 339
97
141 222 310 384 114 145 243
105
54.3 53.6 52.7 52.5 52.6 55.0 54.1 53.1 52.4 52.3 55.5 54.3 53.2
kW
BF
0.02 0.02 0.02 0.02 0.06 0.05 0.03 0.03 0.03 0.12 0.06 0.04 0.04
TC
469 434 383 343 334 490 453 399 358 350 507 467 411
SHC
39
80
151 228 311
44
93
178 270 347
56
110 208
115
kW
60.0 59.3 58.9 59.4 59.9 60.4 59.5 58.7 58.7 59.0 60.8 59.7 58.7
0.02 0.02 0.02 0.02 0.08 0.05 0.03 0.03 0.03 0.14 0.06 0.04 0.04
BF

19,250
62
535
448
40.3
0.04
491
410
43.7
0.04
452
378
47.7
0.04
413
346
52.5
0.04
374
316
58.4
0.05

57
500
500
39.7
0.17
467
467
43.2
0.18
433
433
47.4
0.20
399
399
52.3
0.21
363
363
58.5
0.23

75
721
227
43.6
0.08
676
192
47.0
0.07
621
144
50.9
0.07
572
106
55.6
0.07
520
68
61.2
0.07

72
671
282
42.7
0.06
629
251
46.2
0.06
568
197
49.9
0.05
529
167
54.6
0.05
477
128
59.9
0.05

67
618
403
41.7
0.05
566
358
45.0
0.05
523
323
48.9
0.05
468
276
53.4
0.05
420
240
58.7
0.05

62
550
496
40.6
0.06
502
453
43.9
0.06
467
424
47.9
0.06
433
388
52.7
0.09
393
351
58.3
0.11

57
524
524
40.2
0.26
490
490
43.6
0.27
455
455
47.7
0.28
417
417
52.5
0.29
378
378
58.3
0.31

48/50P2,P3,P4,P5055 (55 TON) HIGH-CAPACITY COIL SUBCOOL MODE


(cont)
Evaporator Air Quantity Cfm
Temp (F)
22,000
24,750
Air Entering
Condenser
Evaporator Air Ewb (F)
(Edb)
75
72
67
62
57
75
72
67
62
57
TC
739 686 746 568 555 752 697 750 582 576
SHC
246 307 653 537 555 263 329 668 569 576
75
kW
43.9 43.0 44.1 40.9 40.7 44.1 43.2 44.2 41.2 41.1
BF
0.09 0.07 0.36 0.10 0.33 0.10 0.08 0.37 0.14 0.39
TC
692 643 573 521 518 704 653 584 531 537
SHC
210 274 389 491 518 226 297 426 520 537
85
kW
47.3 46.5 45.2 44.2 44.1 47.6 46.7 45.4 44.5 44.5
BF
0.09 0.07 0.06 0.11 0.34 0.10 0.08 0.07 0.15 0.40
TC
636 579 535 484 473 666 612 543 495 489
SHC
161 218 359 456 473 197 264 393 486 489
95
kW
51.3 50.1 49.1 48.2 48.1 51.7 50.6 49.3 48.4 48.4
BF
0.08 0.07 0.06 0.12 0.35 0.10 0.08 0.07 0.16 0.40
TC
586 539 475 445 434 593 545 484 454 448
SHC
122 188 308 419 434 134 207 343 446 448
105
kW
56.0 54.8 53.5 52.9 52.8 56.2 55.0 53.7 53.1 53.0
BF
0.09 0.07 0.06 0.13 0.36 0.10 0.08 0.07 0.17 0.42
TC
532 486 427 404 393 543 494 434 410 405
SHC
82
148 272 380 393
98
169 304 405 405
115
kW
61.6 60.1 58.8 58.4 58.3 62.0 60.3 58.9 58.4 58.4
BF
0.09 0.07 0.06 0.15 0.38 0.10 0.08 0.08 0.19 0.43
LEGEND
48/50P3,P5 units only.
BF Bypass Factor
kW
Compressor Motor Power Input
Edb Entering Dry Bulb
SHC Sensible Heat Cap. (1000 Btuh)
Ewb Entering Wet Bulb
TC
Total Cap. (1000 Btuh) Gross
NOTES:
1. The SHC is based on 80 F edb temperature of air entering evaporator coil. For edb temperatures other than 80 F, adjust SHC by
multiplying the correction factor and the cfm and then adding or
subtracting the value from the SHC.

2. Interpolation is permissible.
3. Correction Factor = 1.10 x (1 BF) x (edb 80).
4. Cooling capacities are gross and do not include deduction for
indoor fan motor heat.
5. SHC values provided are in subcooling mode with the gas bypass
valve closed and reflect the maximum SHC in subcooling mode.
The P Series innovative modulating valve system can reduce SHC
as needed to meet the supply air set point requirement with minimal change in latent capacity. This will provide variable SHC to
meet the space load.

71

Performance data (cont)


COOLING CAPACITIES (cont)
48/50P2,P3,P4,P5055 (55 TON) HIGH-CAPACITY COIL HOT GAS REHEAT MODE
Air Entering Evaporator Ewb (F)
Temp (F)
75 Dry Bulb
75 Dry Bulb
Air Ent
62.5 Wet Bulb (50% RH)
65.3 Wet Bulb (60% RH)
Condenser
Air Entering Evaporator Cfm
(Edb)
11,000
13,750
16,500
19,250
22,000
24,750
11,000
13,750
16,500
19,250
22,000
TC
246
262
271
278
283
287
260
274
285
292
297
SHC
35
58
84
111
138
166
-16
-2
15
33
53
80
kW
40.8
40.8
40.9
40.9
41.0
41.1
41.6
42.2
41.8
41.8
41.9
BF
0.02
0.02
0.03
0.05
0.06
0.07
0.02
0.03
0.04
0.05
0.06
TC
252
266
276
282
287
291
264
279
289
296
302
SHC
40
61
86
113
141
168
-14
0
17
36
56
75
kW
40.1
39.7
39.8
39.9
40.0
40.0
40.5
40.6
40.7
40.8
40.9
BF
0.02
0.02
0.03
0.05
0.06
0.07
0.02
0.03
0.04
0.05
0.06
TC
249
265
272
279
284
287
263
276
285
292
297
SHC
37
64
86
113
140
168
-12
-0
17
36
56
70
kW
40.6
41.0
40.9
41.0
41.1
41.2
42.0
41.7
41.9
42.0
42.1
BF
0.02
0.02
0.03
0.05
0.06
0.07
0.02
0.03
0.04
0.05
0.06
TC
256
270
280
287
294
299
270
283
294
304
310
SHC
42
65
91
118
150
176
-7
4
22
43
63
60
kW
38.4
38.6
38.9
39.0
39.5
39.6
39.9
39.7
39.9
40.1
40.2
BF
0.02
0.02
0.03
0.05
0.06
0.07
0.02
0.02
0.04
0.05
0.06
TC
263
282
290
301
304
311
276
293
308
313
322
SHC
48
73
96
126
152
182
-6
10
29
47
69
50
kW
36.5
37.0
37.3
37.4
37.7
37.8
37.8
38.1
38.3
38.6
38.6
BF
0.02
0.02
0.03
0.05
0.06
0.07
0.02
0.02
0.04
0.05
0.06
TC
272
289
304
309
315
319
288
304
320
324
333
SHC
51
76
100
130
149
187
2
15
31
53
71
40
kW
35.3
35.7
35.5
36.2
36.8
36.5
36.4
36.7
36.5
37.2
37.6
BF
0.02
0.02
0.03
0.05
0.06
0.07
0.02
0.02
0.04
0.05
0.07

24,750
302
74
41.9
0.07
307
77
40.9
0.07
301
76
42.3
0.07
311
80
40.3
0.07
327
83
38.8
0.07
337
95
37.9
0.07

48/50P2,P3,P4,P5055 (55 TON) HIGH-CAPACITY COIL HOT GAS REHEAT MODE (cont)
Air Entering Evaporator Ewb (F)
Temp (F)
75 Dry Bulb
75 Dry Bulb
Air Ent
68 Wet Bulb (70% RH)
70.5 Wet Bulb (80% RH)
Condenser
Air Entering Evaporator Cfm
(Edb)
11,000
13,750
16,500
19,250
22,000
24,750
11,000
13,750
16,500
19,250
22,000
TC
271
289
299
307
313
317
286
301
314
322
329
SHC
-67
-61
-52
-41
-29
-16
-114
-117
-115
-111
-106
80
kW
43.3
42.6
42.7
42.8
42.8
42.9
43.6
44.3
43.7
43.7
43.8
BF
0.02
0.03
0.04
0.05
0.07
0.08
0.00
0.05
0.06
0.07
0.08
TC
277
296
304
312
318
323
290
306
318
327
333
SHC
-65
-56
-50
-38
-26
-13
-112
-114
-113
-108
-103
75
kW
41.6
41.5
41.7
41.7
41.8
41.9
42.6
42.6
42.6
42.7
42.8
BF
0.01
0.03
0.04
0.05
0.07
0.08
0.00
0.05
0.06
0.07
0.08
TC
274
291
299
307
312
319
286
302
313
321
328
SHC
-65
-56
-50
-39
-27
-9
-113
-115
-113
-109
-104
70
kW
42.7
43.2
43.0
43.1
43.2
43.7
43.8
43.9
44.1
44.2
44.3
BF
0.02
0.03
0.04
0.05
0.07
0.08
0.00
0.05
0.06
0.07
0.08
TC
280
296
308
319
325
330
293
310
322
334
340
SHC
-62
-54
-45
-33
-21
-8
-109
-110
-108
-104
-99
60
kW
41.1
41.3
41.0
41.1
41.3
41.4
41.7
41.9
42.1
42.2
42.3
BF
0.01
0.03
0.04
0.06
0.07
0.08
0.00
0.05
0.06
0.07
0.09
TC
290
308
320
333
338
344
303
322
338
347
354
SHC
-56
-49
-39
-33
-14
-6
-103
-104
-102
-98
-93
50
kW
38.9
39.2
39.5
39.0
39.7
39.7
40.1
40.3
40.4
40.6
40.7
BF
0.01
0.03
0.04
0.05
0.07
0.08
0.00
0.05
0.06
0.07
0.09
TC
300
319
335
340
349
354
314
337
346
357
364
SHC
-51
-43
-37
-22
-13
0
-98
-103
-97
-96
-90
40
kW
37.5
37.7
37.6
38.3
38.7
38.8
38.6
38.3
39.1
39.6
39.9
BF
0.01
0.03
0.04
0.05
0.08
0.09
0.00
0.05
0.06
0.08
0.10

24,750
334
-100
43.8
0.10
339
-97
42.8
0.10
333
-98
44.3
0.10
345
-93
42.4
0.10
359
-87
40.9
0.10
372
-81
39.3
0.10

LEGEND
BF Bypass Factor
RH
Relative Humidity
Edb Entering Dry Bulb
SHC Sensible Heat Cap. (1000 Btuh)
Ewb Entering Wet Bulb
TC
Total Cap. (1000 Btuh) Gross
kW Compressor Motor Power
Input
NOTES:
1. The SHC is based on 75 F edb temperature of air entering evaporator coil. For edb temperatures other than 75 F, adjust SHC by
multiplying the correction factor and the cfm and then adding or
subtracting the value from the SHC.
2. Interpolation is permissible.

72

3. Correction Factor = 1.10 x (1 BF) x (edb 75).


4. Cooling capacities are gross and do not include deduction for
indoor fan motor heat.
5. Capacity table includes impact of outdoor fan staging at temperatures below 75 F.
6. SHC values provided reflect maximum reheat values with 100%
gas bypass. Negative SHC value indicates that the air entering
the coil is being heated at 100% gas bypass. The P Series innovative modulating valve system will reduce the gas bypass as
required to meet the supply air setpoint with minimal change in
latent capacity. The space will NOT be overheated and the unit
will provide variable SHC to meet the space load.

COOLING CAPACITIES (cont)


48/50P2,P3,P4,P5060 (60 TON) STANDARD CAPACITY COIL STANDARD MODE
Evaporator Air Quantity Cfm
Temp (F)
12,000
15,000
18,000
Air Entering
Condenser
Evaporator Air Ewb (F)
(Edb)
75
72
67
62
57
75
72
67
62
57
75
72
67
TC
751 718 664 611 558 791 752 698 644 589 816 777 721
SHC
308 339 410 474 530 318 368 449 528 575 335 393 485
75
kW
43.7 42.9 41.6 40.7 40.4 44.7 43.7 42.4 41.4 40.5 45.4 44.4 43.0
BF
0.00 0.00 0.17 0.12 0.11 0.00 0.10 0.16 0.13 0.18 0.00 0.22 0.16
TC
730 701 647 593 539 765 733 679 625 573 787 756 701
SHC
298 334 403 465 518 306 361 442 519 558 326 385 478
85
kW
48.1 47.4 46.4 46.0 46.0 49.1 48.2 47.3 46.6 45.7 49.7 48.9 47.8
BF
0.00 0.00 0.16 0.12 0.12 0.00 0.25 0.15 0.13 0.21 0.00 0.20 0.16
TC
711 681 626 572 515 744 711 656 601 554 764 733 677
SHC
291 327 393 454 498 300 353 432 507 553 319 377 468
95
kW
53.5 53.0 52.5 52.3 53.8 54.4 53.8 53.3 52.7 53.2 54.9 54.4 53.7
BF
0.00 0.00 0.14 0.11 0.14 0.00 0.22 0.15 0.12 0.21 0.13 0.19 0.16
TC
686 655 600 546 489 716 683 627 573 531 735 703 647
SHC
281 317 382 442 484 293 343 420 495 531 310 367 456
105
kW
60.0 59.8 59.8 61.6 64.9 60.8 60.5 60.5 61.6 63.0 61.3 61.1 60.8
BF
0.00 0.12 0.13 0.11 0.14 0.00 0.20 0.14 0.12 0.24 0.30 0.18 0.15

TC
700 668 612
657 624 569
682 650 594
SHC

299 354 442


265 306 369

283 332 407

115
kW
68.1 68.7 70.2
68.8 69.1 70.3
67.5 68.0 69.8
BF
0.00 0.25 0.12
0.00 0.18 0.14
0.24 0.17 0.15

21,000
62
667
577
41.9
0.14
647
568
47.0
0.14
622
556
53.3
0.14
591
541
62.3
0.15
554
522
73.7
0.15

57
624
624
41.2
0.26
607
607
46.6
0.27
587
587
53.2
0.30
564
564
62.4
0.33

75
834
351
45.9
0.12
803
341
50.1
0.29
779
334
55.4
0.26
748
324
61.6
0.23
714
313
69.4
0.22

72
796
415
44.8
0.21
773
407
49.3
0.20
748
399
54.8
0.19
717
388
61.4
0.19
681
376
69.5
0.18

67
739
520
43.4
0.17
718
511
48.2
0.17
692
501
54.1
0.17
661
489
61.1
0.17
625
476
70.4
0.16

62
684
621
42.4
0.17
663
611
47.5
0.17
636
598
53.6
0.17
605
576
62.2
0.17
570
556
72.7
0.20

57
653
653
41.7
0.33
636
636
47.0
0.35
616
616
53.1
0.37
591
591
61.8
0.39
562
562
72.3
0.42

48/50P2,P3,P4,P5060 (60 TON) STANDARD CAPACITY COIL STANDARD


MODE (cont)
Evaporator Air Quantity Cfm
Temp (F)
24,000
27,000
Air Entering
Condenser
Evaporator Air Ewb (F)
(Edb)
75
72
67
62
57
75
72
67
62
57
TC
848 809 752 697 677 861 820 762 707 698
SHC
365 436 552 660 677 379 456 583 690 698
75
kW
46.2 45.2 43.7 42.7 42.2 46.6 45.5 44.0 42.8 42.5
BF
0.28 0.21 0.19 0.19 0.39 0.26 0.21 0.20 0.23 0.44
TC
816 785 730 675 660 829 794 740 686 680
SHC
356 428 544 648 660 369 447 575 669 680
85
kW
50.4 49.7 48.5 47.8 47.2 50.8 49.9 48.8 47.7 47.7
BF
0.25 0.20 0.18 0.20 0.41 0.25 0.21 0.19 0.25 0.46
TC
793 759 704 648 638 803 768 713 660 658
SHC
348 419 534 630 638 361 439 565 652 658
95
kW
55.8 55.1 54.4 53.8 53.5 56.1 55.3 54.6 53.7 53.8
BF
0.24 0.20 0.18 0.21 0.43 0.24 0.21 0.19 0.26 0.48
TC
762 728 671 620 614 771 736 680 632 632
SHC
338 408 521 605 614 352 427 552 625 632
105
kW
62.2 61.7 61.3 61.2 61.4 62.6 62.1 61.5 61.2 61.5
BF
0.23 0.20 0.18 0.24 0.45 0.23 0.21 0.19 0.28 0.50
724 691 635 586 584 732 697 643 602 602
TC
SHC
327 396 508 581 584 340 415 538 602 602
115
kW
69.8 69.5 70.3 71.2 71.7 70.1 69.2 70.4 71.3 71.3
BF
0.22 0.19 0.18 0.26 0.48 0.22 0.20 0.19 0.31 0.52
3. SHC is based on 80 F edb temperature of air entering evaporator
LEGEND
coil.
48/50P3,P5 units only.
Below 80 F edb, subtract (corr factor x cfm) from SHC.
Above 80 F edb, add (corr factor x cfm) to SHC.
BF Bypass Factor
kW
Compressor Motor Power Input
Edb Entering Dry Bulb
SHC Sensible Heat Cap. (1000 Btuh)
ENTERING AIR DRY-BULB TEMP (F)
Ewb Entering Wet Bulb
TC
Total Cap. (1000 Btuh) Gross
79
78
77
76
75
under 75
NOTES:
BF
1. Direct interpolation is permissible. Do not extrapolate.
81
82
83
84
85
over 85
2. The following formulas may be used:
Correction Factor
sensible capacity (Btuh)
.05
1.04
2.09
3.14
4.18
5.22
tldb = tedb
Use formula
.10
0.99
1.98
2.97
3.96
4.95
1.10 x cfm
.20
0.88
1.76
2.64
3.52
4.40 shown below
tlwb = Wet-bulb temperature corresponding to enthalpy of air
leaving evaporator coil (hlwb).
Interpolation is permissible.
Correction Factor = 1.10 x (1 BF) x (edb 80).
total capacity (Btuh)
hlwb = hewb
4.
Cooling
capacities are gross and do not include deduction for indoor
4.5 x cfm
fan motor heat.
Where: hewb = Enthalpy of air entering evaporator coil.

73

Performance data (cont)


COOLING CAPACITIES (cont)
48/50P2,P3,P4,P5060 (60 TON) STANDARD CAPACITY COIL SUBCOOL MODE
Evaporator Air Quantity Cfm
Temp (F)
12,000
15,000
18,000
Air Entering
Condenser
Evaporator Air Ewb (F)
(Edb)
75
72
67
62
57
75
72
67
62
57
75
72
67
TC
711 674 615 560 508 754 710 650 600 539 771 734 674
SHC
224 268 339 408 473 247 293 379 469 530 255 315 415
75
48.5 47.7 46.6 45.7 44.8 49.5 48.5 47.2 46.5 45.2 49.9 49.0 47.7
kW
BF
0.02 0.08 0.08 0.08 0.09 0.13 0.11 0.10 0.10 0.14 0.15 0.13 0.13
TC
681 646 589 536 482 723 688 622 567 518 746 702 645
202 246 318 389 446 226 279 357 442 508 239 292 393
SHC
85
kW
52.8 52.0 51.0 50.0 49.2 53.8 53.1 51.6 50.6 49.6 54.3 53.2 52.0
BF
0.04 0.08 0.08 0.08 0.08 0.13 0.11 0.10 0.10 0.16 0.15 0.13 0.13
TC
649 615 561 510 462 681 647 592 539 494 703 668 613
SHC
179 224 298 370 435 193 247 335 422 485 206 268 370
95
kW
57.7 57.0 55.9 55.2 54.8 58.4 57.6 56.5 55.5 54.8 58.9 58.1 56.9
0.05 0.08 0.08 0.08 0.10 0.13 0.11 0.10 0.10 0.17 0.15 0.14 0.13
BF
TC
614 582 531 482 433 644 611 559 509 468 664 631 579
SHC
155 201 276 349 408 168 222 312 400 461 180 243 346
105
63.3 62.6 61.8 61.4 61.3 63.9 63.2 62.1 61.5 61.0 64.4 63.6 62.5
kW
BF
0.05 0.08 0.08 0.08 0.09 0.13 0.11 0.10 0.10 0.18 0.15 0.14 0.13
TC
577 547 498 451 408 604 573 524 477 439 631 592 542
SHC
130 177 253 327 381 142 197 288 376 433 162 216 321
115
kW
69.8 69.3 68.8 68.7 69.0 70.2 69.6 68.9 68.6 68.2 71.0 69.9 69.0
BF
0.05 0.08 0.08 0.08 0.12 0.13 0.11 0.10 0.10 0.20 0.15 0.14 0.13

21,000
62
626
522
47.1
0.12
589
492
51.0
0.12
560
470
55.9
0.13
528
447
61.7
0.13
494
422
68.5
0.13

57
570
570
45.8
0.23
546
546
50.2
0.24
521
521
55.2
0.25
495
495
61.3
0.27
465
465
68.4
0.29

75
789
269
50.3
0.17
755
244
54.4
0.17
727
227
59.6
0.17
679
192
64.7
0.17
644
173
71.2
0.17

72
758
344
49.7
0.16
717
311
53.5
0.16
684
288
58.4
0.16
646
262
64.0
0.16
605
235
70.1
0.16

67
692
450
48.1
0.15
661
427
52.4
0.15
629
404
57.3
0.15
593
379
62.8
0.15
555
353
69.2
0.15

62
634
559
47.0
0.15
605
537
51.3
0.15
575
513
56.2
0.15
542
489
61.8
0.16
506
462
68.5
0.16

57
599
599
46.3
0.31
586
586
51.6
0.32
548
548
55.7
0.33
519
519
61.5
0.34
489
489
68.4
0.36

48/50P2,P3,P4,P5060 (60 TON) STANDARD CAPACITY COIL SUBCOOL


MODE (cont)
Evaporator Air Quantity Cfm
Temp (F)
24,000
27,000
Air Entering
Condenser
Evaporator Air Ewb (F)
(Edb)
75
72
67
62
57
75
72
67
62
57
TC
793 765 795 775 771 804 774 715 780 778
SHC
276 357 681 740 771 288 375 514 758 778
75
kW
50.4 49.8 50.9 50.6 50.6 50.6 50.0 48.7 50.7 50.7
BF
0.20 0.18 0.39 0.48 0.63 0.22 0.20 0.18 0.49 0.65
TC
776 732 674 617 597 767 742 694 637 617
SHC
264 333 459 577 597 262 352 495 624 617
85
kW
55.1 53.9 52.6 51.5 51.1 54.7 54.2 53.3 52.3 51.5
BF
0.19 0.18 0.16 0.18 0.38 0.22 0.19 0.18 0.21 0.43
TC
730 696 640 586 582 754 704 658 596 601
SHC
230 307 436 551 582 262 326 475 578 601
95
kW
59.5 58.7 57.5 56.4 57.0 61.1 58.8 58.1 56.6 57.3
BF
0.19 0.18 0.17 0.18 0.39 0.22 0.20 0.18 0.23 0.45
TC
698 657 604 553 540 699 666 621 577 570
SHC
212 281 410 518 540 214 299 449 562 570
105
kW
65.4 64.2 63.0 61.9 61.7 65.2 64.4 63.6 63.0 62.9
BF
0.19 0.18 0.17 0.20 0.41 0.21 0.19 0.18 0.24 0.46
TC
654 615 574 519 522 654 623 573 530 524
SHC
184 254 394 487 522 186 271 414 516 524
115
kW
71.5 70.3 69.7 68.5 69.5 71.3 70.5 69.4 68.6 68.6
BF
0.19 0.18 0.17 0.22 0.42 0.21 0.20 0.18 0.26 0.47
LEGEND
48/50P3,P5 units only.
BF Bypass Factor
kW
Compressor Motor Power Input
Edb Entering Dry Bulb
SHC Sensible Heat Cap. (1000 Btuh)
Ewb Entering Wet Bulb
TC
Total Cap. (1000 Btuh) Gross
NOTES:
1. The SHC is based on 80 F edb temperature of air entering evaporator coil. For edb temperatures other than 80 F, adjust SHC by
multiplying the correction factor and the cfm and then adding or
subtracting the value from the SHC.

74

2. Interpolation is permissible.
3. Correction Factor = 1.10 x (1 BF) x (edb 80).
4. Cooling capacities are gross and do not include deduction for
indoor fan motor heat.
5. SHC values provided are in subcooling mode with the gas bypass
valve closed and reflect the maximum SHC in subcooling mode.
The P Series innovative modulating valve system can reduce SHC
as needed to meet the supply air set point requirement with minimal change in latent capacity. This will provide variable SHC to
meet the space load.

COOLING CAPACITIES (cont)


48/50P2,P3,P4,P5060 (60 TON) STANDARD CAPACITY COIL HOT GAS REHEAT MODE
Air Entering Evaporator Ewb (F)
Temp (F)
75 Dry Bulb
75 Dry Bulb
Air Ent
62.5 Wet Bulb (50% RH)
65.3 Wet Bulb (60% RH)
Condenser
Air Entering Evaporator Cfm
(Edb)
12,000
15,000
18,000
21,000
24,000
27,000
12,000
15,000
18,000
21,000
24,000
TC
230
246
257
267
274
279
244
262
274
283
289
SHC
8
34
58
78
102
126
-46
-33
-17
-1
16
80
kW
49.2
49.7
49.6
48.6
48.6
48.6
49.9
49.6
49.4
49.3
49.3
BF
0.08
0.10
0.13
0.15
0.16
0.18
0.08
0.10
0.13
0.15
0.17
TC
236
253
263
274
280
285
250
268
280
289
295
SHC
11
33
55
81
105
129
-43
-30
-14
2
19
75
kW
47.5
47.2
47.0
47.0
47.1
47.1
48.3
48.0
47.9
47.8
47.8
BF
0.08
0.10
0.12
0.15
0.16
0.18
0.08
0.10
0.13
0.15
0.17
TC
236
252
263
270
276
281
249
266
277
285
291
SHC
11
33
56
80
104
128
-43
-30
-15
1
18
70
kW
48.6
48.5
48.4
48.7
48.5
48.5
49.5
49.3
49.3
49.3
49.3
BF
0.08
0.10
0.12
0.15
0.16
0.18
0.08
0.10
0.13
0.15
0.17
TC
245
262
273
281
287
291
259
275
287
295
301
SHC
17
38
61
85
109
133
-38
-25
-10
6
23
60
kW
45.6
45.5
45.5
45.6
45.7
45.8
46.5
46.4
46.5
46.5
46.6
BF
0.08
0.10
0.12
0.15
0.16
0.18
0.08
0.10
0.13
0.15
0.17
TC
253
270
282
290
296
301
267
284
296
305
311
SHC
22
43
66
90
114
138
-33
-20
-5
11
28
50
kW
43.0
43.0
43.1
43.3
43.4
43.5
44.0
44.1
44.2
44.3
44.4
BF
0.08
0.10
0.12
0.14
0.16
0.18
0.08
0.10
0.13
0.15
0.17
TC
261
278
290
299
305
310
275
292
304
314
321
SHC
26
48
71
94
118
142
-28
-16
-1
15
32
40
kW
40.9
41.0
41.2
41.4
41.6
41.8
42.0
42.1
42.3
42.6
42.8
BF
0.08
0.10
0.12
0.14
0.16
0.18
0.08
0.10
0.13
0.15
0.17

27,000
294
34
49.3
0.19
300
37
47.8
0.19
295
35
49.4
0.19
306
40
46.7
0.19
316
45
44.6
0.19
327
50
42.9
0.19

48/50P2,P3,P4,P5060 (60 TON) STANDARD CAPACITY COIL HOT GAS REHEAT MODE (cont)
Air Entering Evaporator Ewb (F)
Temp (F)
75 Dry Bulb
75 Dry Bulb
Air Ent
68 Wet Bulb (70% RH)
70.5 Wet Bulb (80% RH)
Condenser
Air Entering Evaporator Cfm
(Edb)
12,000
15,000
18,000
21,000
24,000
27,000
12,000
15,000
18,000
21,000
24,000
TC
259
277
289
298
304
309
272
291
303
312
318
SHC
-99
-94
-86
-77
-67
-56
-149
-151
-150
-148
-144
80
kW
50.7
50.3
50.1
50.1
50.1
50.1
51.6
51.1
51.0
50.9
51.0
BF
0.08
0.11
0.13
0.16
0.18
0.19
0.00
0.12
0.15
0.17
0.19
TC
264
282
295
304
310
315
278
296
309
318
325
SHC
-96
-91
-83
-74
-64
-53
-146
-148
-148
-145
-141
75
kW
49.1
48.8
48.7
48.6
48.7
48.7
50.0
49.7
49.6
49.6
49.6
BF
0.07
0.11
0.13
0.16
0.18
0.19
0.00
0.12
0.15
0.17
0.19
TC
262
279
291
299
305
310
275
292
304
312
318
SHC
-96
-92
-84
-75
-65
-55
-147
-149
-149
-146
-143
70
kW
50.5
50.3
50.2
50.3
50.3
50.4
51.5
51.3
51.3
51.3
51.3
BF
0.08
0.11
0.13
0.16
0.18
0.19
0.00
0.12
0.15
0.17
0.19
TC
272
289
301
309
315
320
285
302
314
323
329
SHC
-91
-87
-79
-70
-60
-50
-142
-144
-144
-142
-138
60
kW
47.6
47.5
47.5
47.6
47.7
47.7
48.7
48.5
48.6
48.7
48.7
BF
0.07
0.11
0.13
0.16
0.18
0.19
0.00
0.12
0.15
0.17
0.19
TC
280
298
310
319
325
330
293
311
324
332
339
SHC
-86
-82
-74
-66
-56
-46
-137
-139
-139
-137
-133
50
kW
45.2
45.1
45.3
45.4
45.6
45.7
46.3
46.3
46.4
46.6
46.7
BF
0.07
0.11
0.13
0.16
0.18
0.19
0.00
0.12
0.15
0.17
0.19
TC
288
306
319
329
337
344
301
320
334
345
353
SHC
-82
-78
-70
-61
-51
-40
-133
-135
-134
-132
-128
40
kW
43.2
43.3
43.5
43.7
43.9
44.0
44.4
44.5
44.7
44.9
45.0
BF
0.07
0.11
0.13
0.16
0.17
0.19
0.00
0.13
0.15
0.17
0.19

27,000
324
-139
51.0
0.21
330
-137
49.6
0.21
323
-138
51.4
0.21
334
-133
48.8
0.21
345
-129
46.8
0.21
359
-123
45.1
0.21

LEGEND
BF Bypass Factor
RH
Relative Humidity
Edb Entering Dry Bulb
SHC Sensible Heat Cap. (1000 Btuh)
Ewb Entering Wet Bulb
TC
Total Cap. (1000 Btuh) Gross
kW Compressor Motor Power
Input

6. SHC values provided reflect maximum reheat values with 100%


gas bypass. Negative SHC value indicates that the air entering
the coil is being heated at 100% gas bypass. The P Series innovative modulating valve system will reduce the gas bypass as
required to meet the supply air setpoint with minimal change in
latent capacity. The space will NOT be overheated and the unit
will provide variable SHC to meet the space load.

NOTES:
1. The SHC is based on 75 F edb temperature of air entering evaporator coil. For edb temperatures other than 75 F, adjust SHC by
multiplying the correction factor and the cfm and then adding or
subtracting the value from the SHC.
2. Interpolation is permissible.
3. Correction Factor = 1.10 x (1 BF) x (edb 75).
4. Cooling capacities are gross and do not include deduction for
indoor fan motor heat.
5. Capacity table includes impact of outdoor fan staging at temperatures below 75 F.

75

Performance data (cont)


COOLING CAPACITIES (cont)
48/50P2,P3,P4,P5060 (60 TON) HIGH-CAPACITY COIL STANDARD MODE
Evaporator Air Quantity Cfm
Temp (F)
12,000
15,000
18,000
Air Entering
Condenser
Evaporator Air Ewb (F)
(Edb)
75
72
67
62
57
75
72
67
62
57
75
72
67
TC
761 725 664 610 561 802 762 700 643 594 830 789 725
SHC
313 349 415 479 539 328 378 457 534 594 347 404 495
75
kW
43.9 43.0 41.4 40.1 39.0 44.9 43.9 42.3 40.9 39.8 45.5 44.5 42.9
BF
0.00 0.00 0.12 0.09 0.08 0.00 0.17 0.12 0.10 0.15 0.10 0.16 0.13
TC
741 705 651 599 549 779 741 685 631 584 808 768 709
SHC
304 342 408 473 525 319 370 450 528 584 340 396 488
85
kW
48.2 47.3 45.9 44.8 44.1 49.2 48.2 46.8 45.5 44.6 49.9 48.9 47.5
BF
0.00 0.09 0.12 0.09 0.09 0.00 0.16 0.12 0.10 0.16 0.25 0.15 0.13
TC
725 690 636 584 534 761 724 668 615 571 787 749 691
SHC
298 336 401 465 520 313 364 443 521 570 333 388 481
95
kW
53.5 52.6 51.5 50.6 50.3 54.6 53.7 52.5 51.6 50.7 55.5 54.5 53.2
BF
0.00 0.07 0.12 0.09 0.11 0.00 0.15 0.12 0.10 0.19 0.21 0.16 0.13
TC
703 669 614 560 508 736 700 643 588 554 760 721 664
SHC
290 328 392 455 498 306 355 432 510 554 324 378 470
105
kW
60.2 59.4 58.7 57.7 59.7 61.6 60.6 59.7 58.5 57.0 63.1 61.7 60.4
BF
0.00 0.06 0.11 0.07 0.11 0.10 0.14 0.11 0.09 0.21 0.19 0.15 0.12

TC
688 630
675 639 582 527 482 706 668 610 554 523
SHC

366 456
276 316 378 440 476 296 343 419 493 523
115
kW
70.1 69.7 69.6 68.0 71.2 72.8 70.9 70.6 71.2 70.6 72.6 71.6
BF
0.00 0.15 0.10 0.07 0.16 0.07 0.13 0.11 0.10 0.25 0.15 0.12

21,000
62
666
588
41.4
0.11
656
580
46.3
0.12
637
571
52.3
0.12
610
556
60.2
0.13
574
540
71.7
0.13

57
628
628
40.7
0.25
619
619
45.3
0.26
605
605
51.3
0.28
584
584
59.0
0.30
555
555
70.8
0.34

75
851
364
46.0
0.21
831
358
50.5
0.19
808
350
56.4
0.18
775
339
64.1
0.17

72
809
426
45.0
0.17
788
418
49.4
0.17
766
410
55.1
0.16
736
400
62.4
0.16

67
744
531
43.4
0.14
727
524
48.0
0.14
707
516
53.7
0.14
679
505
61.0
0.14
644
491
72.2
0.14

62
685
629
42.0
0.15
672
625
46.7
0.14
652
613
52.7
0.15
624
598
60.2
0.16
590
573
71.6
0.18

57
659
659
41.3
0.33
647
647
46.0
0.34
633
633
52.0
0.35
611
611
59.6
0.38
582
582
71.3
0.41

48/50P2,P3,P4,P5060 (60 TON) HIGH-CAPACITY COIL STANDARD MODE


(cont)
Evaporator Air Quantity Cfm
Temp (F)
24,000
27,000
Air Entering
Condenser
Evaporator Air Ewb (F)
(Edb)
75
72
67
62
57
75
72
67
62
57
TC
868 824 759 700 684 882 836 770 714 705
SHC
380 448 565 669 684 393 468 598 689 705
75
kW
46.4 45.4 43.8 42.3 42.0 46.7 45.7 44.1 42.7 42.5
BF
0.19 0.18 0.15 0.18 0.39 0.20 0.19 0.17 0.22 0.44
TC
847 803 741 685 671 861 814 752 698 692
SHC
373 440 558 653 671 387 460 591 688 692
85
kW
51.0 49.9 48.3 47.0 46.6 51.5 50.2 48.7 47.3 47.2
BF
0.18 0.17 0.15 0.20 0.40 0.19 0.18 0.17 0.23 0.45
TC
822 780 720 666 656 835 792 730 679 675
SHC
364 432 550 641 656 377 453 582 664 675
95
kW
57.1 55.6 54.1 52.9 52.5 57.9 56.2 54.5 52.9 53.1
BF
0.19 0.17 0.15 0.20 0.41 0.20 0.18 0.17 0.26 0.46
TC
789 749 690 639 633 798 757 699 653 652
SHC
353 421 538 628 633 365 442 570 648 652
105
kW
65.4 63.2 61.4 60.4 60.1 66.8 63.5 61.7 60.5 60.5
BF
0.18 0.17 0.15 0.21 0.43 0.19 0.17 0.16 0.27 0.48

TC

655 606 603

663 622 622


SHC

524 599 603

556 622 622


115
kW

72.8 71.0 71.9


72.8 72.1 72.0
BF

0.15 0.24 0.46


0.16 0.29 0.51
LEGEND
3. SHC is based on 80 F edb temperature of air entering evaporator
coil.
48/50P3,P5 units only.
Below 80 F edb, subtract (corr factor x cfm) from SHC.
Above 80 F edb, add (corr factor x cfm) to SHC.
BF Bypass Factor
kW
Compressor Motor Power Input
Edb Entering Dry Bulb
SHC Sensible Heat Cap. (1000 Btuh)
Ewb Entering Wet Bulb
TC
Total Cap. (1000 Btuh) Gross
ENTERING AIR DRY-BULB TEMP (F)
79
78
77
76
75
under 75
NOTES:
BF
1. Direct interpolation is permissible. Do not extrapolate.
81
82
83
84
85
over 85
2. The following formulas may be used:
Correction Factor
sensible capacity (Btuh)
.05
1.04
2.09
3.14
4.18
5.22
tldb = tedb
Use formula
.10
0.99
1.98
2.97
3.96
4.95
1.10 x cfm
.20
0.88
1.76
2.64
3.52
4.40 shown below
tlwb = Wet-bulb temperature corresponding to enthalpy of air
leaving evaporator coil (hlwb).
Interpolation is permissible.
Correction Factor = 1.10 x (1 BF) x (edb 80).
total capacity (Btuh)
hlwb = hewb
4.
Cooling
capacities are gross and do not include deduction for indoor
4.5 x cfm
fan motor heat.
Where: hewb = Enthalpy of air entering evaporator coil.

76

COOLING CAPACITIES (cont)


48/50P2,P3,P4,P5060 (60 TON) HIGH-CAPACITY COIL SUBCOOL MODE
Evaporator Air Quantity Cfm
Temp (F)
12,000
15,000
18,000
Air Entering
Condenser
Evaporator Air Ewb (F)
(Edb)
75
72
67
62
57
75
72
67
62
57
75
72
67
TC
703 654 591 539 494 787 718 647 570 533 812 750 672
SHC
188 224 299 378 457 254 280 364 435 520 270 312 406
75
48.9 47.7 46.4 45.3 44.4 50.2 48.9 47.3 45.9 45.1 50.8 49.8 48.0
kW
BF
0.00 0.02 0.02 0.02 0.03 0.05 0.04 0.03 0.03 0.08 0.07 0.05 0.04
TC
661 621 559 506 462 691 658 592 534 504 739 692 606
152 198 273 351 424 163 226 314 405 492 203 261 346
SHC
85
kW
52.7 51.8 50.5 49.5 48.7 53.5 52.7 51.2 50.0 49.3 54.4 53.4 51.6
BF
0.03 0.02 0.02 0.02 0.03 0.06 0.03 0.03 0.03 0.09 0.07 0.05 0.04
TC
621 581 522 472 443 672 611 548 497 473 670 625 583
SHC
120 165 242 323 413 154 187 278 375 462 142 203 331
95
kW
57.4 56.5 55.3 54.4 54.1 58.4 57.2 55.8 54.8 54.2 58.7 57.6 56.4
0.02 0.02 0.02 0.02 0.05 0.05 0.03 0.03 0.03 0.11 0.07 0.05 0.04
BF
576 538 483 436 410 628 564 505 458 441 625 586 521
TC
SHC
87
132 212 294 378 122 151 244 344 432 110 174 280
105
62.9 62.0 61.0 60.8 61.0 64.0 62.6 61.2 60.6 60.4 64.2 63.1 61.6
kW
BF
0.02 0.02 0.02 0.02 0.05 0.05 0.03 0.03 0.03 0.12 0.07 0.05 0.04
TC
529 493 440 396 379 553 514 459 415 400 573 530 473
SHC
52
99
180 265 349
60
113 210 312 387
74
133 243
115
kW
69.6 68.7 68.2 68.7 69.0 70.1 69.0 68.0 68.0 68.4 70.7 69.3 68.0
0.02 0.02 0.02 0.02 0.07 0.05 0.03 0.03 0.03 0.13 0.07 0.05 0.04
BF

21,000
62
588
486
46.4
0.04
555
458
50.4
0.04
516
426
55.2
0.04
474
393
60.6
0.05
432
361
67.7
0.05

57
558
558
45.7
0.16
526
526
49.8
0.17
492
492
54.7
0.19
457
457
60.5
0.20
420
420
67.8
0.22

75
829
285
51.3
0.09
759
221
54.9
0.08
689
159
59.2
0.08
644
127
64.7
0.08
587
86
71.2
0.08

72
752
318
49.9
0.06
710
286
53.8
0.06
668
254
58.4
0.06
597
193
63.4
0.06
544
155
69.6
0.06

67
683
439
48.5
0.05
639
402
52.2
0.05
581
352
56.6
0.05
534
315
61.8
0.05
482
276
68.1
0.05

62
620
554
47.0
0.06
568
507
50.8
0.06
546
490
55.6
0.07
493
440
60.9
0.09
451
400
67.5
0.11

57
588
588
46.4
0.25
553
553
50.4
0.26
516
516
55.1
0.27
478
478
60.6
0.28
438
438
67.6
0.30

48/50P2,P3,P4,P5060 (60 TON) HIGH-CAPACITY COIL SUBCOOL MODE


(cont)
Evaporator Air Quantity Cfm
Temp (F)
24,000
27,000
Air Entering
Condenser
Evaporator Air Ewb (F)
(Edb)
75
72
67
62
57
75
72
67
62
57
TC
847 805 691 637 607 859 791 720 662 654
SHC
301 384 471 599 607 321 379 526 638 654
75
kW
51.7 50.8 48.6 47.4 46.9 52.1 50.7 49.1 47.8 47.6
BF
0.10 0.08 0.07 0.10 0.32 0.11 0.09 0.08 0.14 0.38
TC
776 725 651 591 574 795 737 662 601 599
SHC
239 312 440 552 574 261 337 478 584 599
85
kW
55.3 54.2 52.5 51.2 50.9 55.9 54.5 52.8 51.5 51.5
BF
0.10 0.08 0.07 0.11 0.33 0.11 0.09 0.08 0.15 0.39
TC
701 683 609 550 535 747 694 619 561 554
SHC
173 279 407 513 535 225 304 443 546 554
95
kW
59.6 58.8 57.1 55.8 55.5 60.3 59.1 57.3 56.1 56.0
BF
0.09 0.08 0.07 0.12 0.34 0.11 0.09 0.08 0.16 0.40
TC
656 610 544 509 495 667 618 550 519 512
SHC
141 218 351 474 495 156 238 385 505 512
105
kW
65.1 63.7 62.1 61.2 61.0 65.4 64.0 62.3 61.4 61.3
BF
0.09 0.07 0.07 0.13 0.35 0.11 0.09 0.08 0.17 0.41
TC
599 553 491 465 453 609 561 498 471 466
SHC
100 175 311 432 453 115 197 346 460 466
115
kW
71.7 69.9 68.2 67.6 67.5 72.1 70.1 68.3 67.7 67.6
BF
0.09 0.07 0.07 0.15 0.37 0.11 0.09 0.08 0.19 0.42
LEGEND
48/50P3,P5 units only.
BF Bypass Factor
kW
Compressor Motor Power Input
Edb Entering Dry Bulb
SHC Sensible Heat Cap. (1000 Btuh)
Ewb Entering Wet Bulb
TC
Total Cap. (1000 Btuh) Gross
NOTES:
1. The SHC is based on 80 F edb temperature of air entering evaporator coil. For edb temperatures other than 80 F, adjust SHC by
multiplying the correction factor and the cfm and then adding or
subtracting the value from the SHC.

2. Interpolation is permissible.
3. Correction Factor = 1.10 x (1 BF) x (edb 80).
4. Cooling capacities are gross and do not include deduction for
indoor fan motor heat.
5. SHC values provided are in subcooling mode with the gas bypass
valve closed and reflect the maximum SHC in subcooling mode.
The P Series innovative modulating valve system can reduce SHC
as needed to meet the supply air set point requirement with minimal change in latent capacity. This will provide variable SHC to
meet the space load.

77

Performance data (cont)


COOLING CAPACITIES (cont)
48/50P2,P3,P4,P5060 (60 TON) HIGH-CAPACITY COIL HOT GAS REHEAT MODE
Air Entering Evaporator Ewb (F)
Temp (F)
75 Dry Bulb
75 Dry Bulb
Air Ent
62.5 Wet Bulb (50% RH)
65.3 Wet Bulb (60% RH)
Condenser
Air Entering Evaporator Cfm
(Edb)
12,000
15,000
18,000
21,000
24,000
27,000
12,000
15,000
18,000
21,000
24,000
TC
269
287
298
306
312
316
285
302
314
322
328
SHC
34
60
87
116
145
174
-20
-7
11
31
52
80
kW
47.5
47.1
47.2
47.3
47.5
47.6
47.8
48.2
48.3
48.5
48.6
BF
0.02
0.03
0.04
0.05
0.06
0.08
0.02
0.03
0.04
0.05
0.07
TC
275
292
303
311
316
321
288
307
318
326
332
SHC
38
63
90
118
148
177
-20
-4
14
34
55
75
kW
45.5
45.7
45.9
46.1
46.3
46.4
47.5
46.9
47.1
47.3
47.4
BF
0.02
0.03
0.04
0.05
0.06
0.08
0.02
0.03
0.04
0.05
0.07
TC
269
288
299
306
312
316
286
302
313
321
327
SHC
33
62
89
117
147
176
-20
-5
13
33
54
70
kW
47.6
47.3
47.5
47.8
48.0
48.1
48.4
48.6
48.8
49.1
49.3
BF
0.02
0.03
0.04
0.05
0.06
0.08
0.02
0.03
0.04
0.05
0.07
TC
279
296
307
314
320
324
294
310
321
329
335
SHC
41
66
94
123
150
179
-15
-0
18
38
56
60
kW
45.0
44.8
45.2
45.4
45.7
45.8
45.8
46.1
46.5
46.7
47.0
BF
0.02
0.03
0.04
0.05
0.07
0.08
0.02
0.03
0.04
0.05
0.07
TC
286
303
315
324
331
336
300
319
332
340
348
SHC
46
71
99
126
156
185
-11
5
21
44
61
50
kW
42.3
42.9
43.3
43.6
43.8
44.0
43.7
44.2
44.6
45.0
45.1
BF
0.02
0.03
0.04
0.05
0.07
0.08
0.02
0.03
0.04
0.05
0.07
TC
304
324
327
336
343
349
321
330
343
353
360
SHC
56
82
103
132
161
191
-1
10
27
47
68
40
kW
39.0
39.6
41.6
42.0
42.3
42.4
40.4
42.6
43.0
43.3
43.6
BF
0.02
0.03
0.04
0.05
0.07
0.08
0.02
0.03
0.04
0.06
0.07

27,000
332
73
48.7
0.08
337
77
47.5
0.08
331
76
49.4
0.08
340
78
47.1
0.08
353
83
45.3
0.08
365
91
44.2
0.08

48/50P2,P3,P4,P5060 (60 TON) HIGH-CAPACITY COIL HOT GAS REHEAT MODE (cont)
Air Entering Evaporator Ewb (F)
Temp (F)
75 Dry Bulb
75 Dry Bulb
Air Ent
68 Wet Bulb (70% RH)
70.5 Wet Bulb (80% RH)
Condenser
Air Entering Evaporator Cfm
(Edb)
12,000
15,000
18,000
21,000
24,000
27,000
12,000
15,000
18,000
21,000
24,000
TC
300
317
329
338
344
350
314
332
345
354
361
SHC
-77
-72
-63
-51
-39
-25
-130
-133
-132
-128
-123
80
kW
49.2
49.3
49.5
49.6
49.8
49.8
50.5
50.6
50.7
50.8
50.9
BF
0.02
0.03
0.05
0.06
0.07
0.09
0.00
0.05
0.06
0.08
0.09
TC
304
322
334
342
349
354
318
337
349
359
366
SHC
-75
-69
-60
-49
-35
-22
-128
-131
-129
-126
-120
75
kW
47.9
48.1
48.3
48.5
48.6
48.7
49.2
49.4
49.5
49.7
49.8
BF
0.01
0.03
0.05
0.06
0.07
0.09
0.00
0.05
0.06
0.08
0.09
TC
300
317
328
336
343
347
313
331
343
352
359
SHC
-76
-70
-61
-50
-37
-25
-129
-132
-130
-127
-121
70
kW
49.6
49.9
50.2
50.4
50.6
50.8
51.0
51.3
51.5
51.8
51.9
BF
0.02
0.03
0.05
0.06
0.07
0.09
0.00
0.05
0.06
0.08
0.09
TC
307
325
336
345
351
357
321
339
352
361
368
SHC
-72
-66
-56
-48
-35
-22
-124
-127
-126
-125
-120
60
kW
47.2
47.5
47.9
48.2
48.4
48.5
48.6
48.9
49.2
49.6
49.8
BF
0.01
0.03
0.05
0.06
0.08
0.09
0.00
0.05
0.06
0.08
0.10
TC
315
334
348
357
364
370
330
350
364
374
381
SHC
-67
-60
-54
-38
-30
-17
-120
-121
-123
-120
-115
50
kW
45.2
45.6
46.0
46.3
46.5
46.7
46.6
47.0
47.4
47.6
47.8
BF
0.01
0.03
0.05
0.06
0.08
0.09
0.00
0.05
0.07
0.08
0.10
TC
325
346
360
370
378
384
340
362
376
387
395
SHC
-62
-54
-47
-36
-23
-10
-117
-119
-118
-114
-109
40
kW
43.5
44.1
44.4
44.6
44.8
45.0
45.0
45.4
45.7
45.9
46.1
BF
0.01
0.03
0.05
0.06
0.08
0.09
0.00
0.05
0.07
0.08
0.10

27,000
367
-116
51.0
0.10
372
-114
49.9
0.10
364
-115
52.1
0.10
373
-114
50.0
0.11
387
-108
47.9
0.11
402
-102
46.3
0.11

LEGEND
BF Bypass Factor
RH
Relative Humidity
Edb Entering Dry Bulb
SHC Sensible Heat Cap. (1000 Btuh)
Ewb Entering Wet Bulb
TC
Total Cap. (1000 Btuh) Gross
kW Compressor Motor Power
Input
NOTES:
1. The SHC is based on 75 F edb temperature of air entering evaporator coil. For edb temperatures other than 75 F, adjust SHC by
multiplying the correction factor and the cfm and then adding or
subtracting the value from the SHC.
2. Interpolation is permissible.

78

3. Correction Factor = 1.10 x (1 BF) x (edb 75).


4. Cooling capacities are gross and do not include deduction for
indoor fan motor heat.
5. Capacity table includes impact of outdoor fan staging at temperatures below 75 F.
6. SHC values provided reflect maximum reheat values with 100%
gas bypass. Negative SHC value indicates that the air entering
the coil is being heated at 100% gas bypass. The P Series innovative modulating valve system will reduce the gas bypass as
required to meet the supply air setpoint with minimal change in
latent capacity. The space will NOT be overheated and the unit
will provide variable SHC to meet the space load.

COOLING CAPACITIES (cont)


48/50P2,P3,P4,P5070 (70 TON) STANDARD CAPACITY COIL STANDARD MODE
Evaporator Air Quantity Cfm
Temp (F)
14,000
17,500
21,000
Air Entering
Condenser
Evaporator Air Ewb (F)
(Edb)
75
72
67
62
57
75
72
67
62
57
75
72
67
TC
843 802 744 685 629 880 839 779 720 675 905 863 803
SHC
345 392 472 549 604 363 423 520 614 663 384 453 564
75
kW
46.7 45.7 44.2 42.9 41.9 47.7 46.6 45.0 43.7 42.7 48.4 47.3 45.6
BF
0.00 0.19 0.09 0.07 0.11 0.00 0.14 0.10 0.08 0.20 0.21 0.12 0.11
TC
822 783 726 667 612 857 819 759 700 655 880 839 782
SHC
334 384 464 540 599 356 416 511 604 655 376 444 555
85
kW
51.3 50.2 48.9 47.7 46.8 52.2 51.2 49.7 48.5 47.6 52.9 51.8 50.3
BF
0.00 0.17 0.09 0.07 0.11 0.00 0.13 0.10 0.08 0.20 0.19 0.12 0.11
TC
799 763 703 645 588 830 791 734 674 635 854 816 755
SHC
326 376 454 531 584 347 406 501 591 635 367 435 545
95
kW
56.7 55.8 54.6 53.2 52.7 57.6 56.5 55.4 54.3 53.4 58.3 57.4 55.9
BF
0.00 0.15 0.09 0.06 0.11 0.27 0.11 0.09 0.08 0.22 0.17 0.12 0.10
TC
771 734 674 618 569 799 764 703 644 612 821 784 722
SHC
313 365 442 517 561 337 395 488 577 612 356 424 531
105
kW
63.1 62.3 61.1 60.4 60.1 64.0 63.2 62.0 61.8 61.1 64.8 63.8 62.5
BF
0.00 0.13 0.07 0.06 0.15 0.20 0.11 0.09 0.08 0.25 0.15 0.11 0.10
TC
736 699 642 587 541 763 728 669 610 587 782 747 687
SHC
304 353 427 503 541 325 383 474 560 587 344 411 517
115
kW
70.7 69.4 70.3 69.2 71.0 71.7 71.3 70.8 71.4 70.3 72.5 72.1 71.4
BF
0.00 0.10 0.08 0.05 0.17 0.16 0.10 0.09 0.09 0.28 0.14 0.11 0.10

24,500
62
744
672
44.3
0.10
722
660
49.1
0.11
695
647
54.8
0.11
664
631
62.0
0.11
629
602
71.1
0.14

57
710
710
43.5
0.27
694
694
48.3
0.29
673
673
54.1
0.31
648
648
61.4
0.34
620
620
71.0
0.37

75
924
402
48.9
0.17
900
394
53.4
0.16
871
385
58.9
0.16
836
374
65.3
0.15
796
361
73.0
0.14

72
882
479
47.7
0.13
860
471
52.3
0.13
832
461
57.9
0.13
798
449
64.4
0.13
760
435
72.4
0.13

67
820
606
46.1
0.12
798
597
50.8
0.12
771
586
56.4
0.12
737
573
62.9
0.11
700
559
71.7
0.11

62
761
722
44.7
0.13
739
709
49.5
0.14
711
688
55.1
0.15
679
672
62.0
0.16
650
641
70.8
0.20

57
741
741
44.2
0.35
724
724
49.0
0.36
702
702
54.8
0.38
676
676
61.8
0.41
646
646
71.1
0.43

48/50P2,P3,P4,P5070 (70 TON) STANDARD CAPACITY COIL STANDARD


MODE (cont)
Evaporator Air Quantity Cfm
Temp (F)
28,000
30,000
Air Entering
Condenser
Evaporator Air Ewb (F)
(Edb)
75
72
67
62
57
75
72
67
62
57
TC
938 897 834 774 767 945 903 840 782 779
SHC
419 504 646 758 767 428 518 668 776 779
75
kW
49.3 48.1 46.4 45.0 44.8 49.5 48.3 46.6 45.1 45.1
BF
0.17 0.15 0.13 0.18 0.41 0.17 0.15 0.14 0.21 0.44
TC
913 874 811 751 749 919 880 816 763 761
SHC
411 496 637 745 749 420 510 659 756 761
85
kW
53.8 52.8 51.1 49.7 49.6 54.0 52.9 51.3 50.0 49.9
BF
0.16 0.14 0.13 0.18 0.43 0.16 0.15 0.14 0.23 0.45
TC
883 845 782 728 726 889 850 788 741 738
SHC
401 486 626 723 726 411 500 648 727 738
95
kW
59.3 58.3 56.7 55.4 55.4 59.5 58.4 56.9 55.7 55.7
BF
0.16 0.14 0.13 0.21 0.44 0.16 0.15 0.14 0.27 0.47
TC
847 809 747 701 698 853 815 753 710 710
SHC
390 474 615 692 698 400 488 635 710 710
105
kW
65.7 64.7 63.1 62.1 62.2 65.9 64.9 63.4 62.4 62.4
BF
0.15 0.14 0.12 0.24 0.46 0.15 0.14 0.14 0.27 0.49
806 770 710 673 668 811 774 714 680 679
TC
SHC
378 460 598 655 668 387 474 619 680 679
115
kW
73.5 72.8 71.9 71.1 71.2 73.7 72.9 72.2 71.3 71.4
BF
0.14 0.14 0.13 0.29 0.49 0.15 0.14 0.14 0.30 0.51
LEGEND
3. SHC is based on 80 F edb temperature of air entering evaporator
coil.
48/50P3,P5 units only.
Below 80 F edb, subtract (corr factor x cfm) from SHC.
Above 80 F edb, add (corr factor x cfm) to SHC.
BF Bypass Factor
kW
Compressor Motor Power Input
Edb Entering Dry Bulb
SHC Sensible Heat Cap. (1000 Btuh)
ENTERING AIR DRY-BULB TEMP (F)
Ewb Entering Wet Bulb
TC
Total Cap. (1000 Btuh) Gross
79
78
77
76
75
under 75
NOTES:
BF
1. Direct interpolation is permissible. Do not extrapolate.
81
82
83
84
85
over 85
2. The following formulas may be used:
Correction Factor
sensible capacity (Btuh)
.05
1.04
2.09
3.14
4.18
5.22
tldb = tedb
Use formula
.10
0.99
1.98
2.97
3.96
4.95
1.10 x cfm
.20
0.88
1.76
2.64
3.52
4.40 shown below
tlwb = Wet-bulb temperature corresponding to enthalpy of air
leaving evaporator coil (hlwb).
Interpolation is permissible.
Correction Factor = 1.10 x (1 BF) x (edb 80).
total capacity (Btuh)
hlwb = hewb
4.
Cooling
capacities are gross and do not include deduction for indoor
4.5 x cfm
fan motor heat.
Where: hewb = Enthalpy of air entering evaporator coil.

79

Performance data (cont)


COOLING CAPACITIES (cont)
48/50P2,P3,P4,P5070 (70 TON) STANDARD CAPACITY COIL SUBCOOL MODE
Evaporator Air Quantity Cfm
Temp (F)
14,000
17,500
21,000
Air Entering
Condenser
Evaporator Air Ewb (F)
(Edb)
75
72
67
62
57
75
72
67
62
57
75
72
67
TC
791 754 683 644 576 812 787 726 676 627 855 813 749
SHC
255 309 393 488 552 257 336 440 549 627 292 363 483
75
52.2 51.2 49.8 48.8 47.5 53.0 52.1 50.6 49.5 48.6 54.3 53.1 51.2
kW
BF
0.00 0.07 0.07 0.06 0.08 0.13 0.10 0.09 0.09 0.16 0.14 0.12 0.11
TC
738 724 665 618 551 774 738 695 637 588 815 776 716
209 286 374 467 529 229 295 416 517 588 264 337 458
SHC
85
kW
56.1 55.5 54.1 53.2 51.8 57.2 56.2 54.9 53.6 52.5 58.4 57.3 55.4
BF
0.00 0.07 0.07 0.07 0.09 0.13 0.10 0.09 0.09 0.17 0.14 0.12 0.11
TC
723 687 627 595 543 754 718 660 579 577 775 739 681
SHC
205 258 344 453 522 221 285 390 467 577 236 310 431
95
kW
61.7 60.7 59.2 59.7 59.3 62.6 61.6 60.1 58.3 59.8 63.3 62.2 60.6
0.05 0.07 0.07 0.07 0.11 0.13 0.10 0.09 0.09 0.17 0.14 0.12 0.11
BF
TC
685 650 605 565 517 714 679 624 593 552 733 699 643
SHC
178 232 333 431 498 193 257 364 491 552 207 282 405
105
67.3 66.4 65.9 65.7 65.5 68.2 67.2 65.8 66.2 65.9 68.8 67.8 66.3
kW
BF
0.05 0.07 0.07 0.07 0.12 0.13 0.10 0.09 0.09 0.20 0.14 0.12 0.11
TC
643 610 583 532 483 670 637 584 558 522 705 655 602
SHC
150 205 321 408 471 163 229 337 467 522 195 253 377
115
kW
73.7 72.8 73.4 72.9 72.7 74.5 73.6 72.2 73.1 73.1 75.9 74.1 72.7
BF
0.04 0.07 0.07 0.07 0.15 0.12 0.10 0.09 0.09 0.22 0.14 0.12 0.11

24,500
62
671
580
49.6
0.11
668
584
54.3
0.11
646
571
60.7
0.11
613
547
66.7
0.12
576
522
73.5
0.12

57
663
663
49.3
0.26
623
623
53.3
0.27
616
616
60.4
0.28
586
586
66.6
0.30
555
555
73.5
0.32

75
875
308
54.8
0.16
833
279
59.0
0.15
791
250
63.8
0.15
747
221
69.3
0.15
718
209
76.3
0.15

72
813
369
53.1
0.14
793
361
57.8
0.14
753
333
62.7
0.14
713
305
68.2
0.14
668
275
74.5
0.14

67
767
525
51.7
0.13
731
497
56.1
0.13
696
472
61.1
0.13
657
444
66.7
0.13
615
416
73.0
0.13

62
703
648
50.4
0.14
672
624
54.7
0.14
639
597
59.6
0.15
604
560
65.3
0.17
567
526
71.7
0.19

57
681
681
49.6
0.34
675
675
55.7
0.35
621
621
59.2
0.36
589
589
64.9
0.37
554
554
71.4
0.39

48/50P2,P3,P4,P5070 (70 TON) STANDARD CAPACITY COIL SUBCOOL


MODE (cont)
Evaporator Air Quantity Cfm
Temp (F)
28,000
30,000
Air Entering
Condenser
Evaporator Air Ewb (F)
(Edb)
75
72
67
62
57
75
72
67
62
57
TC
703 888 847 777 717 897 854 783 696 728
SHC
648 332 414 561 717 333 428 582 681 728
75
kW
50.4 55.2 54.1 52.3 50.5 55.5 54.3 52.5 50.4 50.8
BF
0.17 0.15 0.14 0.17 0.40 0.18 0.16 0.15 0.20 0.43
TC
847 806 744 683 675 853 812 750 715 709
SHC
294 385 536 657 675 303 399 558 700 709
85
kW
59.4 58.2 56.5 54.9 54.7 59.6 58.4 56.7 56.9 56.3
BF
0.17 0.15 0.14 0.19 0.41 0.18 0.16 0.15 0.22 0.44
TC
802 766 707 677 669 808 771 713 685 608
SHC
265 357 510 654 669 273 370 531 674 608
95
kW
64.2 63.1 61.4 61.5 61.3 64.4 63.3 61.6 61.8 59.2
BF
0.17 0.15 0.14 0.20 0.42 0.18 0.16 0.15 0.23 0.45
TC
758 724 668 643 635 763 729 672 652 646
SHC
235 328 482 623 635 242 341 503 643 646
105
kW
69.7 68.6 67.0 67.5 67.4 69.8 68.8 67.2 67.8 67.6
BF
0.17 0.15 0.14 0.22 0.43 0.18 0.16 0.15 0.24 0.46
TC
711 697 624 581 573 738 701 629 587 610
SHC
204 318 453 561 573 235 331 474 580 610
115
kW
75.9 75.7 73.3 72.1 71.9 77.0 75.9 73.5 72.3 74.3
BF
0.17 0.15 0.14 0.23 0.45 0.18 0.16 0.15 0.26 0.48
LEGEND
48/50P3,P5 units only.
BF Bypass Factor
kW
Compressor Motor Power Input
Edb Entering Dry Bulb
SHC Sensible Heat Cap. (1000 Btuh)
Ewb Entering Wet Bulb
TC
Total Cap. (1000 Btuh) Gross
NOTES:
1. The SHC is based on 80 F edb temperature of air entering evaporator coil. For edb temperatures other than 80 F, adjust SHC by
multiplying the correction factor and the cfm and then adding or
subtracting the value from the SHC.

80

2. Interpolation is permissible.
3. Correction Factor = 1.10 x (1 BF) x (edb 80).
4. Cooling capacities are gross and do not include deduction for
indoor fan motor heat.
5. SHC values provided are in subcooling mode with the gas bypass
valve closed and reflect the maximum SHC in subcooling mode.
The P Series innovative modulating valve system can reduce SHC
as needed to meet the supply air set point requirement with minimal change in latent capacity. This will provide variable SHC to
meet the space load.

COOLING CAPACITIES (cont)


48/50P2,P3,P4,P5070 (70 TON) STANDARD CAPACITY COIL HOT GAS REHEAT MODE
Air Entering Evaporator Ewb (F)
Temp (F)
75 Dry Bulb
75 Dry Bulb
Air Ent
62.5 Wet Bulb (50% RH)
65.3 Wet Bulb (60% RH)
Condenser
Air Entering Evaporator Cfm
(Edb)
14,000
17,500
21,000
24,500
28,000
30,000
14,000
17,500
21,000
24,500
28,000
TC
258
276
287
296
301
304
274
292
303
311
317
SHC
19
47
77
107
138
155
-43
-25
-5
16
38
80
kW
54.3
54.0
53.9
53.9
53.9
53.9
55.0
54.7
54.6
54.6
54.7
BF
0.07
0.09
0.11
0.13
0.15
0.16
0.07
0.09
0.11
0.13
0.15
TC
265
283
294
302
308
311
280
298
310
318
325
SHC
23
51
80
111
141
158
-40
-22
-2
20
41
75
kW
52.5
52.3
52.2
52.2
52.2
52.2
53.2
53.1
53.0
53.0
53.0
BF
0.07
0.09
0.11
0.13
0.15
0.16
0.07
0.09
0.11
0.13
0.15
TC
271
288
300
309
315
318
286
304
316
325
331
SHC
26
54
84
114
144
162
-36
-19
2
23
44
70
kW
50.9
50.8
50.6
50.7
50.7
50.7
51.7
51.5
51.4
51.6
51.6
BF
0.07
0.09
0.11
0.13
0.15
0.16
0.07
0.09
0.11
0.13
0.15
TC
268
284
294
301
307
309
282
298
308
316
321
SHC
26
54
83
112
142
159
-37
-20
0
21
42
60
kW
51.9
51.9
52.1
52.2
52.4
52.4
52.9
53.1
53.1
53.3
53.4
BF
0.07
0.09
0.11
0.13
0.15
0.16
0.07
0.09
0.11
0.13
0.15
TC
278
295
305
313
319
321
293
309
320
328
333
SHC
33
60
89
119
149
166
-30
-13
6
27
49
50
kW
48.9
49.0
49.2
49.4
49.6
49.7
50.0
50.2
50.4
50.6
50.7
BF
0.07
0.09
0.11
0.13
0.15
0.16
0.07
0.09
0.11
0.13
0.15
TC
286
304
315
322
328
331
301
318
329
338
345
SHC
38
65
94
124
154
171
-25
-8
12
33
55
40
kW
46.4
46.6
46.9
47.2
47.4
47.5
47.6
47.8
48.1
48.4
48.7
BF
0.07
0.09
0.11
0.13
0.15
0.16
0.07
0.09
0.11
0.13
0.15

30,000
320
51
54.7
0.16
327
54
53.0
0.16
334
57
51.6
0.16
324
55
53.5
0.16
336
61
50.8
0.16
349
67
48.8
0.16

48/50P2,P3,P4,P5070 (70 TON) STANDARD CAPACITY COIL HOT GAS REHEAT MODE (cont)
Air Entering Evaporator Ewb (F)
Temp (F)
75 Dry Bulb
75 Dry Bulb
Air Ent
68 Wet Bulb (70% RH)
70.5 Wet Bulb (80% RH)
Condenser
Air Entering Evaporator Cfm
(Edb)
14,000
17,500
21,000
24,500
28,000
30,000
14,000
17,500
21,000
24,500
28,000
TC
289
307
319
327
333
336
303
321
333
342
348
SHC
-105
-97
-86
-73
-59
-51
-162
-163
-160
-156
-149
80
kW
55.8
55.6
55.5
55.5
55.5
55.5
56.8
56.6
56.4
56.5
56.6
BF
0.07
0.10
0.12
0.14
0.16
0.17
0.02
0.12
0.14
0.15
0.17
TC
296
314
326
334
340
344
310
328
340
350
357
SHC
-101
-93
-82
-70
-56
-48
-159
-159
-157
-152
-145
75
kW
54.1
53.9
53.9
54.0
54.0
54.0
55.2
54.9
54.9
55.0
55.0
BF
0.07
0.10
0.12
0.14
0.16
0.17
0.02
0.12
0.14
0.15
0.17
TC
302
320
332
341
349
352
316
334
348
358
366
SHC
-98
-90
-79
-66
-52
-44
-155
-156
-153
-148
-142
70
kW
52.6
52.5
52.4
52.5
52.6
52.6
53.7
53.5
53.5
53.6
53.6
BF
0.07
0.10
0.12
0.14
0.16
0.17
0.02
0.12
0.14
0.15
0.17
TC
296
312
322
330
335
338
308
325
335
343
349
SHC
-99
-91
-80
-68
-55
-47
-156
-158
-156
-151
-145
60
kW
54.2
54.2
54.3
54.5
54.7
54.7
55.5
55.5
55.7
55.8
55.9
BF
0.07
0.10
0.12
0.14
0.16
0.17
0.02
0.12
0.14
0.15
0.17
TC
306
323
334
342
348
351
319
337
348
356
363
SHC
-92
-84
-74
-62
-48
-40
-150
-151
-149
-144
-138
50
kW
51.3
51.4
51.6
51.8
52.0
52.1
52.6
52.7
52.9
53.1
53.4
BF
0.07
0.10
0.12
0.14
0.16
0.17
0.02
0.12
0.14
0.15
0.17
TC
315
333
345
355
362
366
329
348
361
371
379
SHC
-87
-79
-68
-55
-42
-34
-144
-145
-142
-137
-131
40
kW
48.9
49.1
49.5
49.8
50.0
50.1
50.3
50.6
50.9
51.2
51.4
BF
0.07
0.10
0.12
0.14
0.16
0.17
0.03
0.12
0.14
0.16
0.17

30,000
351
-145
56.6
0.18
361
-141
55.1
0.18
370
-137
53.7
0.18
351
-141
56.0
0.18
367
-134
53.4
0.18
382
-127
51.5
0.18

LEGEND
BF Bypass Factor
RH
Relative Humidity
Edb Entering Dry Bulb
SHC Sensible Heat Cap. (1000 Btuh)
Ewb Entering Wet Bulb
TC
Total Cap. (1000 Btuh) Gross
kW Compressor Motor Power
Input

6. SHC values provided reflect maximum reheat values with 100%


gas bypass. Negative SHC value indicates that the air entering
the coil is being heated at 100% gas bypass. The P Series innovative modulating valve system will reduce the gas bypass as
required to meet the supply air setpoint with minimal change in
latent capacity. The space will NOT be overheated and the unit
will provide variable SHC to meet the space load.

NOTES:
1. The SHC is based on 75 F edb temperature of air entering evaporator coil. For edb temperatures other than 75 F, adjust SHC by
multiplying the correction factor and the cfm and then adding or
subtracting the value from the SHC.
2. Interpolation is permissible.
3. Correction Factor = 1.10 x (1 BF) x (edb 75).
4. Cooling capacities are gross and do not include deduction for
indoor fan motor heat.
5. Capacity table includes impact of outdoor fan staging at temperatures below 75 F.

81

Performance data (cont)


COOLING CAPACITIES (cont)
48/50P2,P3,P4,P5070 (70 TON) HIGH-CAPACITY COIL STANDARD MODE
Evaporator Air Quantity Cfm
Temp (F)
14,000
17,500
21,000
Air Entering
Condenser
Evaporator Air Ewb (F)
(Edb)
75
72
67
62
57
75
72
67
62
57
75
72
67
TC
863 814 754 690 636 905 862 793 728 686 934 889 820
SHC
353 404 485 563 630 380 441 539 635 686 403 473 589
75
kW
47.8 46.6 44.8 43.2 42.0 48.8 47.6 45.7 44.1 43.1 49.6 48.3 46.4
BF
0.00 0.05 0.03 0.01 0.05 0.12 0.05 0.03 0.02 0.16 0.08 0.05 0.04
TC
838 797 729 678 623 876 834 772 715 673 903 861 798
SHC
345 396 475 556 621 370 430 530 628 673 392 463 581
85
kW
52.1 50.9 49.1 47.7 46.4 53.2 51.9 50.1 48.7 47.7 53.9 52.7 50.9
BF
0.00 0.06 0.02 0.02 0.05 0.10 0.05 0.03 0.03 0.17 0.07 0.05 0.03
TC
814 777 711 662 611 853 813 753 693 660 879 841 777
SHC
337 388 467 548 608 362 422 522 618 660 384 455 572
95
kW
57.3 56.2 54.4 53.2 51.9 58.4 57.3 55.6 54.1 53.1 59.3 58.1 56.3
BF
0.00 0.05 0.02 0.02 0.07 0.08 0.05 0.03 0.02 0.19 0.06 0.05 0.03
TC
791 755 691 640 593 828 788 728 667 642 852 813 750
SHC
330 379 458 537 593 354 413 512 607 642 375 445 561
105
kW
63.6 62.6 60.7 59.9 58.6 64.9 63.7 62.1 60.4 59.8 65.8 64.7 63.0
BF
0.00 0.05 0.02 0.02 0.09 0.07 0.04 0.03 0.02 0.21 0.06 0.04 0.03
TC
761 725 664 611 571 794 758 697 639 618 817 779 717
SHC
319 367 446 523 571 341 401 498 591 618 363 433 548
115
kW
71.2 70.3 68.2 69.1 67.5 72.7 71.9 70.5 69.9 68.5 73.9 73.0 71.5
BF
0.12 0.04 0.02 0.02 0.13 0.06 0.04 0.03 0.03 0.24 0.06 0.04 0.03

24,500
62
753
700
44.7
0.04
734
692
49.2
0.04
718
683
54.8
0.04
691
668
61.3
0.05
659
646
69.6
0.07

57
729
729
44.2
0.25
714
714
48.7
0.27
699
699
54.2
0.29
680
680
60.8
0.31
654
654
69.2
0.33

75
956
423
50.2
0.07
926
413
54.5
0.07
902
405
60.0
0.07
871
395
66.6
0.06
834
382
75.0
0.06

72
911
504
48.9
0.05
882
494
53.3
0.05
860
486
58.7
0.05
831
476
65.4
0.05
795
463
73.8
0.05

67
839
639
46.9
0.04
817
630
51.4
0.04
795
621
56.9
0.04
766
610
63.5
0.04
731
595
72.0
0.04

62
771
757
45.3
0.06
753
742
49.7
0.08
734
730
55.2
0.09
711
702
61.6
0.13
682
682
69.2
0.14

57
764
764
45.1
0.33
746
746
49.6
0.35
730
730
55.1
0.36
709
709
61.6
0.38
682
682
70.0
0.40

48/50P2,P3,P4,P5070 (70 TON) HIGH-CAPACITY COIL STANDARD MODE


(cont)
Evaporator Air Quantity Cfm
Temp (F)
28,000
30,000
Air Entering
Condenser
Evaporator Air Ewb (F)
(Edb)
75
72
67
62
57
75
72
67
62
57
TC
973 926 853 795 792 980 934 860 809 806
SHC
442 534 685 787 792 453 551 711 802 806
75
kW
50.6 49.3 47.4 45.9 45.9 50.8 49.5 47.5 46.3 46.2
BF
0.07 0.06 0.05 0.14 0.39 0.07 0.06 0.05 0.18 0.42
TC
942 898 830 773 772 950 905 839 783 785
SHC
432 524 676 769 772 443 541 701 783 785
85
kW
55.0 53.7 51.8 50.4 50.3 55.2 54.0 52.0 50.7 50.7
BF
0.07 0.05 0.05 0.16 0.41 0.07 0.06 0.05 0.20 0.44
TC
918 874 808 753 756 924 881 815 766 768
SHC
424 516 667 753 756 435 532 692 766 768
95
kW
60.5 59.2 57.3 55.7 55.8 60.7 59.5 57.6 56.1 56.2
BF
0.07 0.05 0.05 0.17 0.42 0.07 0.06 0.05 0.21 0.45
TC
885 843 779 732 734 891 850 784 746 746
SHC
414 505 654 732 734 424 522 679 746 746
105
kW
67.1 65.9 64.0 62.2 62.4 67.4 66.1 64.2 62.8 62.8
BF
0.07 0.05 0.05 0.20 0.44 0.07 0.06 0.06 0.23 0.47
847 806 742 706 706 853 812 747 718 717
TC
SHC
401 492 640 706 706 412 509 664 718 717
115
kW
75.8 74.5 72.8 70.6 70.7 76.1 74.9 72.9 71.0 71.0
BF
0.06 0.05 0.05 0.22 0.46 0.07 0.05 0.06 0.26 0.49
LEGEND
3. SHC is based on 80 F edb temperature of air entering evaporator
coil.
48/50P3,P5 units only.
Below 80 F edb, subtract (corr factor x cfm) from SHC.
Above 80 F edb, add (corr factor x cfm) to SHC.
BF Bypass Factor
kW
Compressor Motor Power Input
Edb Entering Dry Bulb
SHC Sensible Heat Cap. (1000 Btuh)
Ewb Entering Wet Bulb
TC
Total Cap. (1000 Btuh) Gross
ENTERING AIR DRY-BULB TEMP (F)
79
78
77
76
75
under 75
NOTES:
BF
1. Direct interpolation is permissible. Do not extrapolate.
81
82
83
84
85
over 85
2. The following formulas may be used:
Correction Factor
sensible capacity (Btuh)
.05
1.04
2.09
3.14
4.18
5.22
tldb = tedb
Use formula
.10
0.99
1.98
2.97
3.96
4.95
1.10 x cfm
.20
0.88
1.76
2.64
3.52
4.40 shown below
tlwb = Wet-bulb temperature corresponding to enthalpy of air
leaving evaporator coil (hlwb).
Interpolation is permissible.
Correction Factor = 1.10 x (1 BF) x (edb 80).
total capacity (Btuh)
hlwb = hewb
4.
Cooling
capacities are gross and do not include deduction for indoor
4.5 x cfm
fan motor heat.
Where: hewb = Enthalpy of air entering evaporator coil.

82

COOLING CAPACITIES (cont)


48/50P2,P3,P4,P5070 (70 TON) HIGH-CAPACITY COIL SUBCOOL MODE
Evaporator Air Quantity Cfm
Temp (F)
14,000
17,500
21,000
Air Entering
Condenser
Evaporator Air Ewb (F)
(Edb)
75
72
67
62
57
75
72
67
62
57
75
72
67
TC
798 759 699 643 604 835 793 732 675 635 861 817 754
SHC
236 292 386 478 578 253 320 433 544 631 271 348 478
75
52.9 51.8 50.3 49.0 48.1 53.9 52.8 51.1 49.7 48.8 54.7 53.5 51.8
kW
BF
0.03 0.02 0.02 0.02 0.03 0.06 0.04 0.03 0.04 0.11 0.07 0.05 0.05
TC
762 725 668 610 586 795 757 697 644 600 817 778 718
207 264 361 451 558 222 290 405 519 598 237 316 449
SHC
85
kW
57.0 56.0 54.6 53.3 52.7 58.0 57.0 55.3 54.0 53.1 58.7 57.6 55.9
BF
0.03 0.02 0.02 0.02 0.06 0.06 0.04 0.03 0.04 0.12 0.07 0.05 0.05
TC
723 687 632 578 560 752 716 661 610 568 773 735 679
SHC
176 235 333 427 534 189 259 377 492 562 203 284 419
95
kW
62.0 61.0 59.6 58.4 58.2 62.8 61.8 60.3 59.1 58.1 63.5 62.4 60.9
0.03 0.02 0.02 0.02 0.07 0.06 0.04 0.03 0.04 0.12 0.07 0.05 0.05
BF
680 646 594 548 533 706 671 618 570 528 724 688 636
TC
SHC
145 205 305 405 508 155 226 346 463 528 167 249 387
105
67.7 66.7 65.6 65.2 65.1 68.5 67.5 66.1 65.3 64.7 69.1 68.0 66.5
kW
BF
0.02 0.02 0.02 0.02 0.09 0.06 0.04 0.03 0.04 0.15 0.07 0.05 0.05
TC
633 601 553 504 502 656 624 575 532 507 671 638 590
SHC
111 173 276 373 479 120 193 316 442 507 130 214 355
115
kW
74.5 73.8 73.2 73.1 73.5 75.1 74.2 73.4 73.0 72.9 75.5 74.6 73.6
0.02 0.02 0.02 0.02 0.10 0.06 0.04 0.03 0.04 0.17 0.07 0.05 0.05
BF

24,500
62
698
607
50.3
0.05
664
579
54.5
0.05
631
553
59.6
0.06
592
523
65.6
0.06
559
494
73.1
0.08

57
669
669
49.6
0.21
638
638
53.9
0.22
607
607
59.0
0.23
569
569
65.2
0.25
536
536
72.9
0.27

75
879
288
55.3
0.08
833
253
59.3
0.08
787
218
64.0
0.08
737
181
69.5
0.08
683
143
75.9
0.08

72
836
375
54.1
0.06
793
342
58.1
0.06
749
308
62.9
0.06
701
273
68.4
0.06
649
236
74.9
0.06

67
769
522
52.2
0.06
733
493
56.4
0.06
693
462
61.3
0.06
648
429
66.9
0.06
601
396
73.7
0.06

62
716
664
50.8
0.08
683
636
55.0
0.08
649
600
60.0
0.10
610
563
65.8
0.12
572
527
73.1
0.13

57
700
700
50.3
0.29
667
667
54.6
0.30
634
634
59.7
0.31
598
598
65.7
0.33
556
556
73.0
0.34

48/50P2,P3,P4,P5070 (70 TON) HIGH-CAPACITY COIL SUBCOOL MODE


(cont)
Evaporator Air Quantity Cfm
Temp (F)
28,000
30,000
Air Entering
Condenser
Evaporator Air Ewb (F)
(Edb)
75
72
67
62
57
75
72
67
62
57
TC
894 849 783 733 723 901 851 788 741 736
SHC
305 403 567 705 723 314 414 590 728 736
75
kW
55.7 54.5 52.7 51.2 51.0 56.0 54.4 52.8 51.5 51.3
BF
0.09 0.08 0.07 0.12 0.36 0.10 0.08 0.08 0.15 0.40
TC
845 805 745 701 692 852 810 750 709 703
SHC
269 368 536 675 692 278 383 560 696 703
85
kW
59.7 58.5 56.8 55.5 55.3 59.9 58.7 56.9 55.7 55.6
BF
0.09 0.08 0.07 0.13 0.37 0.10 0.08 0.08 0.16 0.40
TC
798 760 703 666 659 804 765 708 673 664
SHC
233 334 503 641 659 241 348 527 662 664
95
kW
64.4 63.3 61.6 60.5 60.3 64.6 63.4 61.8 60.7 60.5
BF
0.09 0.08 0.07 0.15 0.38 0.10 0.08 0.08 0.17 0.41
TC
747 710 657 626 619 752 715 661 633 628
SHC
195 297 470 603 619 203 311 492 624 628
105
kW
69.9 68.8 67.2 66.3 66.1 70.0 68.9 67.4 66.5 66.4
BF
0.09 0.08 0.07 0.16 0.39 0.10 0.08 0.08 0.18 0.42
TC
691 657 609 583 573 696 660 613 589 582
SHC
156 260 436 563 573 164 273 458 583 582
115
kW
76.2 75.2 73.9 73.3 73.2 76.4 75.3 74.0 73.4 73.3
BF
0.09 0.08 0.07 0.18 0.41 0.10 0.08 0.08 0.20 0.44
LEGEND
48/50P3,P5 units only.
BF Bypass Factor
kW
Compressor Motor Power Input
Edb Entering Dry Bulb
SHC Sensible Heat Cap. (1000 Btuh)
Ewb Entering Wet Bulb
TC
Total Cap. (1000 Btuh) Gross
NOTES:
1. The SHC is based on 80 F edb temperature of air entering evaporator coil. For edb temperatures other than 80 F, adjust SHC by
multiplying the correction factor and the cfm and then adding or
subtracting the value from the SHC.

2. Interpolation is permissible.
3. Correction Factor = 1.10 x (1 BF) x (edb 80).
4. Cooling capacities are gross and do not include deduction for
indoor fan motor heat.
5. SHC values provided are in subcooling mode with the gas bypass
valve closed and reflect the maximum SHC in subcooling mode.
The P Series innovative modulating valve system can reduce SHC
as needed to meet the supply air set point requirement with minimal change in latent capacity. This will provide variable SHC to
meet the space load.

83

Performance data (cont)


COOLING CAPACITIES (cont)
48/50P2,P3,P4,P5070 (70 TON) HIGH-CAPACITY COIL HOT GAS REHEAT MODE
Air Entering Evaporator Ewb (F)
Temp (F)
75 Dry Bulb
75 Dry Bulb
Air Ent
62.5 Wet Bulb (50% RH)
65.3 Wet Bulb (60% RH)
Condenser
Air Entering Evaporator Cfm
(Edb)
14,000
17,500
21,000
24,500
28,000
30,000
14,000
17,500
21,000
24,500
28,000
TC
286
304
315
323
329
331
303
320
331
339
345
SHC
34
66
98
132
166
186
-30
-10
12
35
61
80
kW
51.9
51.4
51.6
51.8
51.9
52.0
52.4
52.5
52.7
52.9
53.0
BF
0.02
0.03
0.05
0.06
0.07
0.08
0.02
0.04
0.05
0.06
0.07
TC
293
310
321
329
334
337
307
325
336
344
350
SHC
39
70
102
136
170
190
-28
-7
15
39
64
75
kW
49.7
49.8
50.1
50.4
50.5
50.6
51.5
51.2
51.4
51.6
51.8
BF
0.02
0.03
0.05
0.06
0.07
0.08
0.02
0.04
0.05
0.06
0.07
TC
297
314
325
333
339
342
312
330
341
349
355
SHC
42
72
105
139
173
192
-24
-5
17
41
67
70
kW
48.5
48.7
49.0
49.2
49.4
49.5
49.7
50.0
50.3
50.5
50.7
BF
0.02
0.03
0.05
0.06
0.07
0.08
0.02
0.04
0.05
0.06
0.07
TC
293
308
318
324
330
332
306
322
332
339
344
SHC
42
71
104
137
171
191
-24
-6
16
40
65
60
kW
50.5
51.0
51.5
51.8
52.1
52.2
52.0
52.6
53.0
53.3
53.6
BF
0.02
0.03
0.05
0.06
0.08
0.08
0.02
0.04
0.05
0.06
0.08
TC
301
316
326
333
339
342
315
330
341
348
354
SHC
47
76
109
143
174
193
-19
0
22
42
67
50
kW
48.0
48.6
49.1
49.5
49.8
49.9
49.5
50.1
50.6
51.0
51.3
BF
0.02
0.03
0.05
0.06
0.08
0.09
0.02
0.04
0.05
0.07
0.08
TC
306
322
333
341
347
350
321
337
348
357
364
SHC
51
81
114
145
179
198
-14
5
24
47
73
40
kW
45.9
46.6
47.2
47.5
47.8
47.9
47.5
48.2
48.6
49.0
49.3
BF
0.02
0.03
0.05
0.06
0.08
0.09
0.02
0.04
0.05
0.07
0.08

30,000
347
75
53.1
0.08
353
78
51.9
0.08
357
81
50.8
0.08
346
80
53.8
0.08
356
81
51.4
0.09
367
87
49.4
0.09

48/50P2,P3,P4,P5070 (70 TON) HIGH-CAPACITY COIL HOT GAS REHEAT MODE (cont)
Air Entering Evaporator Ewb (F)
Temp (F)
75 Dry Bulb
75 Dry Bulb
Air Ent
68 Wet Bulb (70% RH)
70.5 Wet Bulb (80% RH)
Condenser
Air Entering Evaporator Cfm
(Edb)
14,000
17,500
21,000
24,500
28,000
30,000
14,000
17,500
21,000
24,500
28,000
TC
316
335
347
355
361
364
332
350
362
370
377
SHC
-96
-86
-73
-59
-44
-34
-154
-155
-153
-148
-141
80
kW
54.4
53.8
54.0
54.2
54.4
54.4
55.0
55.1
55.4
55.5
55.7
BF
0.02
0.04
0.05
0.07
0.08
0.09
0.00
0.06
0.07
0.09
0.10
TC
323
341
352
360
366
369
336
355
367
376
382
SHC
-91
-82
-71
-57
-41
-31
-154
-153
-150
-145
-138
75
kW
52.3
52.5
52.8
53.0
53.1
53.2
54.4
53.9
54.1
54.3
54.5
BF
0.02
0.04
0.05
0.07
0.08
0.09
0.00
0.06
0.07
0.09
0.10
TC
326
345
357
365
372
375
342
360
372
382
390
SHC
-90
-80
-68
-54
-37
-28
-148
-150
-147
-142
-134
70
kW
51.5
51.4
51.7
51.9
52.1
52.2
52.4
52.8
53.0
53.3
53.4
BF
0.02
0.04
0.05
0.07
0.08
0.09
0.00
0.06
0.07
0.09
0.10
TC
320
336
346
353
359
361
333
349
360
368
373
SHC
-89
-81
-69
-55
-39
-34
-149
-151
-148
-143
-136
60
kW
53.6
54.1
54.6
54.9
55.2
55.5
55.2
55.7
56.1
56.5
56.7
BF
0.02
0.04
0.05
0.07
0.08
0.10
0.00
0.06
0.07
0.09
0.10
TC
329
345
356
363
369
371
342
359
369
378
383
SHC
-83
-75
-62
-53
-38
-29
-143
-145
-147
-136
-135
50
kW
51.1
51.7
52.2
52.6
52.8
52.9
52.7
53.3
53.9
54.1
54.5
BF
0.02
0.04
0.05
0.08
0.09
0.10
0.00
0.06
0.08
0.09
0.11
TC
335
352
365
374
381
385
349
368
383
390
398
SHC
-78
-74
-62
-40
-32
-23
-138
-138
-150
-129
-129
40
kW
49.1
49.7
50.2
50.7
50.8
51.0
50.7
51.3
50.8
52.2
52.4
BF
0.02
0.04
0.06
0.07
0.09
0.10
0.00
0.06
0.08
0.09
0.11

30,000
380
-136
55.7
0.11
385
-133
54.5
0.11
393
-130
53.5
0.11
376
-132
56.8
0.11
386
-131
54.6
0.12
401
-124
52.5
0.12

LEGEND
BF Bypass Factor
RH
Relative Humidity
Edb Entering Dry Bulb
SHC Sensible Heat Cap. (1000 Btuh)
Ewb Entering Wet Bulb
TC
Total Cap. (1000 Btuh) Gross
kW Compressor Motor Power
Input
NOTES:
1. The SHC is based on 75 F edb temperature of air entering evaporator coil. For edb temperatures other than 75 F, adjust SHC by
multiplying the correction factor and the cfm and then adding or
subtracting the value from the SHC.
2. Interpolation is permissible.
3. Correction Factor = 1.10 x (1 BF) x (edb 75).
4. Cooling capacities are gross and do not include deduction for
indoor fan motor heat.
5. Capacity table includes impact of outdoor fan staging at temperatures below 75 F.

84

6. SHC values provided reflect maximum reheat values with 100%


gas bypass. Negative SHC value indicates that the air entering
the coil is being heated at 100% gas bypass. The P Series innovative modulating valve system will reduce the gas bypass as
required to meet the supply air setpoint with minimal change in
latent capacity. The space will NOT be overheated and the unit
will provide variable SHC to meet the space load.

COOLING CAPACITIES (cont)


48/50P2,P3,P4,P5075 (75 TON) STANDARD CAPACITY COIL STANDARD MODE
Evaporator Air Quantity Cfm
Temp (F)
14,000
17,500
21,000
Air Entering
Condenser
Evaporator Air Ewb (F)
(Edb)
75
72
67
62
57
75
72
67
62
57
75
72
67
TC
889 852 787 724 663 933 893 826 763 705 960 917 854
SHC
365 410 491 568 635 377 443 540 634 695 402 472 585
75
kW
50.7 49.6 48.1 46.7 45.8 51.8 50.7 49.0 47.7 46.5 52.6 51.4 49.7
BF
0.00 0.00 0.10 0.07 0.08 0.00 0.16 0.10 0.09 0.16 0.30 0.14 0.11
TC
869 831 766 703 641 909 870 803 740 686 935 892 829
SHC
357 402 482 558 619 372 435 530 623 679 394 463 575
85
kW
55.8 54.9 53.4 52.1 51.2 57.0 55.9 54.4 53.1 52.0 57.7 56.5 55.1
BF
0.00 0.00 0.10 0.07 0.09 0.00 0.15 0.10 0.08 0.18 0.24 0.13 0.11
TC
844 803 740 679 615 880 841 775 711 662 906 864 799
SHC
346 392 470 547 602 364 424 518 609 662 384 453 563
95
kW
62.0 60.8 59.8 58.3 58.6 63.0 62.1 60.7 59.5 58.9 63.9 62.7 61.4
BF
0.00 0.19 0.09 0.06 0.10 0.00 0.14 0.10 0.08 0.19 0.20 0.12 0.11
TC
813 773 709 649 592 846 806 742 679 637 869 828 765
SHC
331 380 457 532 582 353 412 504 593 637 372 440 549
105
kW
69.2 68.3 67.4 67.1 67.2 70.3 69.1 68.6 68.7 68.2 71.1 69.7 69.1
BF
0.00 0.16 0.08 0.06 0.13 0.00 0.12 0.09 0.08 0.22 0.17 0.11 0.10
TC
779 739 676 616 562 808 770 706 643 610 830 791 726
SHC
316 367 443 516 560 340 398 489 576 610 360 427 533
115
kW
78.2 78.6 77.5 78.0 79.9 79.3 78.4 78.9 79.8 79.5 80.3 79.9 79.3
BF
0.00 0.14 0.08 0.06 0.14 0.20 0.11 0.09 0.08 0.25 0.15 0.11 0.10

24,500
62
789
693
48.3
0.10
765
682
53.8
0.10
735
667
60.2
0.10
701
650
69.2
0.11
664
631
79.9
0.11

57
745
745
47.3
0.24
726
726
52.9
0.26
704
704
59.1
0.28
678
678
68.0
0.31
647
647
79.4
0.34

75
981
420
53.3
0.20
957
413
58.4
0.18
925
403
64.6
0.17
886
390
71.8
0.16
845
377
81.0
0.15

72
937
499
52.0
0.14
910
490
57.1
0.13
884
480
63.5
0.13
846
467
70.7
0.13
806
452
80.3
0.13

67
874
627
50.3
0.12
848
617
55.6
0.12
817
605
61.9
0.12
781
591
69.6
0.12
742
574
79.6
0.12

62
809
747
48.8
0.12
783
734
54.2
0.13
752
716
60.5
0.13
717
693
69.1
0.15
683
669
78.5
0.17

57
780
780
48.0
0.32
760
760
53.5
0.33
735
735
60.1
0.36
708
708
68.7
0.38
677
677
79.4
0.41

48/50P2,P3,P4,P5075 (75 TON) STANDARD CAPACITY COIL STANDARD


MODE (cont)
Evaporator Air Quantity Cfm
Temp (F)
28,000
30,000
Air Entering
Condenser
Evaporator Air Ewb (F)
(Edb)
75
72
67
62
57
75
72
67
62
57
TC
1000 955 889 823 808 1007 964 896 830 822
SHC
439 525 668 791 808 448 539 690 811 822
75
kW
53.7 52.5 50.7 49.1 48.7 53.9 52.7 50.9 49.3 49.1
BF
0.18 0.15 0.13 0.16 0.38 0.18 0.15 0.14 0.18 0.41
TC
972 930 862 798 787 979 937 869 804 801
SHC
430 516 658 773 787 439 530 680 797 801
85
kW
58.9 57.7 56.0 54.5 54.2 59.1 57.9 56.2 54.6 54.5
BF
0.17 0.14 0.13 0.17 0.40 0.17 0.15 0.14 0.19 0.43
TC
939 898 831 766 762 946 904 837 777 775
SHC
420 505 645 757 762 429 519 667 771 775
95
kW
65.0 64.0 62.3 60.8 60.6 65.2 64.2 62.4 61.0 61.0
BF
0.16 0.14 0.13 0.17 0.42 0.16 0.15 0.14 0.21 0.44
TC
899 859 793 736 733 905 864 800 748 746
SHC
407 491 631 725 733 416 505 653 739 746
105
kW
72.2 71.2 69.9 68.9 69.0 72.4 71.4 70.2 69.0 69.2
BF
0.16 0.14 0.13 0.21 0.44 0.16 0.15 0.13 0.25 0.47
857 818 753 705 701 863 823 759 717 713
TC
SHC
393 477 615 692 701 403 491 637 702 713
115
kW
81.3 80.8 80.2 79.2 79.5 81.6 81.0 80.2 79.3 79.5
BF
0.15 0.14 0.13 0.25 0.46 0.15 0.14 0.13 0.29 0.49
LEGEND
3. SHC is based on 80 F edb temperature of air entering evaporator
coil.
48/50P3,P5 units only.
Below 80 F edb, subtract (corr factor x cfm) from SHC.
Above 80 F edb, add (corr factor x cfm) to SHC.
BF Bypass Factor
kW
Compressor Motor Power Input
Edb Entering Dry Bulb
SHC Sensible Heat Cap. (1000 Btuh)
ENTERING AIR DRY-BULB TEMP (F)
Ewb Entering Wet Bulb
TC
Total Cap. (1000 Btuh) Gross
79
78
77
76
75
under 75
NOTES:
BF
1. Direct interpolation is permissible. Do not extrapolate.
81
82
83
84
85
over 85
2. The following formulas may be used:
Correction Factor
sensible capacity (Btuh)
.05
1.04
2.09
3.14
4.18
5.22
tldb = tedb
Use formula
.10
0.99
1.98
2.97
3.96
4.95
1.10 x cfm
.20
0.88
1.76
2.64
3.52
4.40 shown below
tlwb = Wet-bulb temperature corresponding to enthalpy of air
leaving evaporator coil (hlwb).
Interpolation is permissible.
Correction Factor = 1.10 x (1 BF) x (edb 80).
total capacity (Btuh)
hlwb = hewb
4.
Cooling
capacities are gross and do not include deduction for indoor
4.5 x cfm
fan motor heat.
Where: hewb = Enthalpy of air entering evaporator coil.

85

Performance data (cont)


COOLING CAPACITIES (cont)
48/50P2,P3,P4,P5075 (75 TON) STANDARD CAPACITY COIL SUBCOOL MODE
Evaporator Air Quantity Cfm
Temp (F)
14,000
17,500
21,000
Air Entering
Condenser
Evaporator Air Ewb (F)
(Edb)
75
72
67
62
57
75
72
67
62
57
75
72
67
TC
847 771 745 681 619 871 829 760 720 659 900 856 789
SHC
281 299 432 507 582 284 347 447 572 649 301 373 494
75
56.6 54.6 54.8 53.8 53.0 57.3 56.2 54.5 54.5 53.9 58.2 57.0 55.2
kW
BF
0.00 0.07 0.07 0.06 0.07 0.06 0.10 0.09 0.09 0.14 0.14 0.12 0.11
TC
803 756 715 653 593 832 817 713 668 632 860 819 755
246 293 403 486 562 254 344 410 527 623 272 346 468
SHC
85
kW
61.1 59.9 59.9 59.1 58.1 61.9 62.1 58.9 57.8 58.4 62.8 61.7 59.9
BF
0.00 0.07 0.07 0.06 0.08 0.16 0.10 0.09 0.09 0.15 0.14 0.12 0.11
TC
759 720 681 623 566 794 755 694 603 606 818 779 717
SHC
212 266 378 464 540 227 292 399 471 599 242 317 441
95
kW
66.4 65.4 65.6 64.8 64.5 67.4 66.4 64.7 62.6 64.9 68.2 67.1 65.4
0.00 0.07 0.07 0.06 0.09 0.14 0.10 0.09 0.09 0.16 0.14 0.12 0.11
BF
TC
718 681 647 590 533 751 714 654 621 576 773 736 677
SHC
183 238 354 440 508 198 263 371 501 576 212 287 412
105
72.6 71.6 72.3 71.5 71.1 73.6 72.6 71.0 71.9 72.1 74.3 73.2 71.6
kW
BF
0.06 0.07 0.07 0.06 0.11 0.14 0.10 0.09 0.09 0.17 0.14 0.12 0.11
TC
674 639 611 555 510 704 669 613 581 554 724 689 633
SHC
154 209 330 415 486 167 233 342 472 540 180 256 382
115
kW
79.6 78.7 80.2 79.6 80.4 80.5 79.5 78.1 79.8 79.7 81.2 80.1 78.6
BF
0.05 0.07 0.07 0.07 0.13 0.13 0.10 0.09 0.09 0.18 0.14 0.12 0.11

24,500
62
725
610
53.7
0.11
681
576
58.3
0.11
682
585
66.0
0.11
645
559
72.6
0.11
607
533
80.3
0.12

57
674
674
52.5
0.22
670
670
59.6
0.24
641
641
65.6
0.25
610
610
72.3
0.27
576
576
80.2
0.29

75
914
310
58.7
0.16
878
287
63.4
0.16
859
282
69.9
0.16
789
226
74.9
0.15
764
219
83.1
0.15

72
868
391
57.4
0.14
838
371
62.2
0.14
797
341
67.6
0.14
752
311
73.7
0.13
704
279
80.6
0.13

67
809
530
55.8
0.12
773
508
60.4
0.13
734
480
65.9
0.13
692
451
72.1
0.13
647
421
79.0
0.13

62
743
665
54.1
0.13
710
639
58.8
0.13
674
611
64.3
0.14
634
582
70.5
0.14
622
570
80.7
0.17

57
709
709
53.3
0.31
680
680
58.1
0.32
648
648
63.7
0.33
613
613
70.0
0.34
577
577
77.3
0.36

48/50P2,P3,P4,P5075 (75 TON) STANDARD CAPACITY COIL SUBCOOL


MODE (cont)
Evaporator Air Quantity Cfm
Temp (F)
28,000
30,000
Air Entering
Condenser
Evaporator Air Ewb (F)
(Edb)
75
72
67
62
57
75
72
67
62
57
TC
939 893 823 780 736 947 900 830 764 773
SHC
329 424 575 736 736 338 437 596 741 773
75
kW
59.3 58.1 56.2 55.8 54.0 59.6 58.3 56.4 54.7 55.8
BF
0.17 0.15 0.14 0.16 0.37 0.18 0.16 0.15 0.17 0.40
TC
893 852 787 724 706 900 884 817 731 719
SHC
302 394 547 685 706 310 433 593 703 719
85
kW
63.9 62.7 60.9 59.2 58.8 64.1 64.0 62.2 59.4 59.1
BF
0.17 0.15 0.14 0.16 0.38 0.18 0.16 0.15 0.19 0.41
TC
849 810 747 687 673 854 817 753 696 685
SHC
271 365 519 649 673 283 373 540 670 685
95
kW
69.2 68.0 66.3 64.6 64.3 69.4 68.3 66.5 64.9 64.6
BF
0.17 0.15 0.14 0.18 0.39 0.18 0.16 0.15 0.21 0.42
TC
802 764 705 650 637 830 770 710 658 649
SHC
235 334 489 614 637 280 346 510 634 649
105
kW
75.3 74.1 72.4 70.9 70.6 76.7 74.3 72.6 71.1 70.9
BF
0.17 0.15 0.14 0.20 0.41 0.18 0.16 0.15 0.22 0.44
TC
750 715 658 635 599 787 720 663 617 609
SHC
206 301 458 605 599 236 314 479 596 609
115
kW
82.1 81.0 79.3 80.9 77.8 83.9 81.2 79.5 78.2 78.0
BF
0.17 0.15 0.14 0.21 0.42 0.18 0.16 0.15 0.24 0.45
LEGEND
48/50P3,P5 units only.
BF Bypass Factor
kW
Compressor Motor Power Input
Edb Entering Dry Bulb
SHC Sensible Heat Cap. (1000 Btuh)
Ewb Entering Wet Bulb
TC
Total Cap. (1000 Btuh) Gross
NOTES:
1. The SHC is based on 80 F edb temperature of air entering evaporator coil. For edb temperatures other than 80 F, adjust SHC by
multiplying the correction factor and the cfm and then adding or
subtracting the value from the SHC.

86

2. Interpolation is permissible.
3. Correction Factor = 1.10 x (1 BF) x (edb 80).
4. Cooling capacities are gross and do not include deduction for
indoor fan motor heat.
5. SHC values provided are in subcooling mode with the gas bypass
valve closed and reflect the maximum SHC in subcooling mode.
The P Series innovative modulating valve system can reduce SHC
as needed to meet the supply air set point requirement with minimal change in latent capacity. This will provide variable SHC to
meet the space load.

COOLING CAPACITIES (cont)


48/50P2,P3,P4,P5075 (75 TON) STANDARD CAPACITY COIL HOT GAS REHEAT MODE
Air Entering Evaporator Ewb (F)
Temp (F)
75 Dry Bulb
75 Dry Bulb
Air Ent
62.5 Wet Bulb (50% RH)
65.3 Wet Bulb (60% RH)
Condenser
Air Entering Evaporator Cfm
(Edb)
14,000
17,500
21,000
24,500
28,000
30,000
14,000
17,500
21,000
24,500
28,000
TC
268
288
302
311
319
322
285
305
319
329
336
SHC
11
39
67
97
127
144
-52
-35
-16
5
26
80
kW
58.8
58.5
58.3
58.2
58.2
58.2
59.6
59.2
59.0
58.9
59.0
BF
0.07
0.09
0.11
0.13
0.15
0.16
0.07
0.09
0.11
0.13
0.15
TC
275
296
309
319
327
330
292
313
327
336
344
SHC
15
43
71
101
131
148
-48
-31
-12
9
30
75
kW
56.8
56.5
56.4
56.3
56.3
56.4
57.7
57.3
57.2
57.2
57.2
BF
0.07
0.09
0.11
0.13
0.15
0.15
0.07
0.09
0.11
0.13
0.15
TC
282
302
316
326
334
337
299
319
334
344
351
SHC
19
47
75
105
135
152
-44
-27
-8
12
33
70
kW
55.0
54.7
54.6
54.6
54.7
54.7
55.9
55.6
55.5
55.5
55.5
BF
0.07
0.09
0.11
0.13
0.15
0.15
0.07
0.09
0.11
0.13
0.15
TC
279
297
309
317
323
326
294
312
324
332
338
SHC
19
46
74
103
132
149
-45
-29
-11
9
30
60
kW
56.5
56.5
56.5
56.7
56.8
56.9
57.6
57.6
57.8
57.9
58.1
BF
0.07
0.09
0.11
0.13
0.15
0.16
0.07
0.09
0.11
0.13
0.15
TC
290
309
322
330
337
340
305
324
337
346
352
SHC
26
53
81
110
139
156
-38
-22
-3
16
37
50
kW
53.0
53.1
53.3
53.5
53.7
53.8
54.2
54.3
54.5
54.8
55.0
BF
0.07
0.09
0.11
0.13
0.15
0.15
0.07
0.09
0.11
0.13
0.15
TC
300
319
332
341
348
351
315
335
348
357
364
SHC
32
59
87
116
145
162
-32
-16
3
23
44
40
kW
50.1
50.3
50.6
50.9
51.1
51.2
51.4
51.6
51.9
52.2
52.5
BF
0.07
0.09
0.11
0.13
0.15
0.15
0.07
0.09
0.11
0.13
0.15

30,000
339
38
59.0
0.16
347
42
57.2
0.16
355
46
55.5
0.16
341
42
58.2
0.16
355
49
55.1
0.16
367
56
52.6
0.16

48/50P2,P3,P4,P5075 (75 TON) STANDARD CAPACITY COIL HOT GAS REHEAT MODE (cont)
Air Entering Evaporator Ewb (F)
Temp (F)
75 Dry Bulb
75 Dry Bulb
Air Ent
68 Wet Bulb (70% RH)
70.5 Wet Bulb (80% RH)
Condenser
Air Entering Evaporator Cfm
(Edb)
14,000
17,500
21,000
24,500
28,000
30,000
14,000
17,500
21,000
24,500
28,000
TC
301
322
336
345
353
356
317
337
351
361
369
SHC
-114
-107
-97
-86
-73
-65
-173
-175
-174
-170
-164
80
kW
60.5
60.1
59.9
59.9
59.9
59.9
61.5
61.1
60.9
61.0
61.0
BF
0.07
0.10
0.12
0.14
0.16
0.17
0.00
0.13
0.14
0.15
0.17
TC
308
329
343
353
361
364
324
345
359
369
377
SHC
-110
-103
-94
-82
-69
-61
-169
-171
-170
-166
-161
75
kW
58.6
58.3
58.1
58.1
58.2
58.2
59.6
59.3
59.2
59.2
59.3
BF
0.07
0.10
0.12
0.14
0.16
0.17
0.00
0.13
0.14
0.15
0.17
TC
315
336
351
360
368
372
330
352
366
376
385
SHC
-107
-100
-90
-78
-65
-58
-166
-168
-166
-162
-157
70
kW
56.8
56.5
56.4
56.6
56.6
56.7
58.0
57.7
57.6
57.7
57.7
BF
0.07
0.10
0.12
0.14
0.16
0.17
0.00
0.06
0.14
0.15
0.17
TC
308
326
339
347
353
356
321
340
352
361
368
SHC
-108
-102
-92
-81
-68
-61
-167
-170
-169
-165
-160
60
kW
58.9
59.0
59.1
59.3
59.4
59.5
60.3
60.3
60.4
60.6
60.8
BF
0.07
0.10
0.12
0.14
0.16
0.17
0.00
0.12
0.14
0.15
0.17
TC
320
339
352
361
367
371
334
353
366
375
382
SHC
-101
-95
-85
-74
-61
-54
-160
-162
-161
-158
-153
50
kW
55.6
55.7
55.9
56.2
56.4
56.5
57.0
57.1
57.4
57.6
57.7
BF
0.07
0.10
0.12
0.14
0.16
0.17
0.00
0.14
0.14
0.15
0.17
TC
330
350
363
372
380
384
344
364
377
388
397
SHC
-95
-88
-79
-68
-55
-48
-154
-156
-155
-152
-146
40
kW
52.8
53.1
53.4
53.7
54.0
54.1
54.3
54.5
54.9
55.2
55.4
BF
0.07
0.10
0.12
0.14
0.16
0.17
0.00
0.06
0.14
0.16
0.17

30,000
372
-160
60.9
0.18
380
-157
59.3
0.18
390
-153
57.8
0.18
371
-157
60.9
0.18
385
-150
57.8
0.18
401
-143
55.6
0.18

LEGEND
BF Bypass Factor
RH
Relative Humidity
Edb Entering Dry Bulb
SHC Sensible Heat Cap. (1000 Btuh)
Ewb Entering Wet Bulb
TC
Total Cap. (1000 Btuh) Gross
kW Compressor Motor Power
Input
NOTES:
1. The SHC is based on 75 F edb temperature of air entering evaporator coil. For edb temperatures other than 75 F, adjust SHC by
multiplying the correction factor and the cfm and then adding or
subtracting the value from the SHC.
2. Interpolation is permissible.

3. Correction Factor = 1.10 x (1 BF) x (edb 75).


4. Cooling capacities are gross and do not include deduction for
indoor fan motor heat.
5. Capacity table includes impact of outdoor fan staging at temperatures below 75 F.
6. SHC values provided reflect maximum reheat values with 100%
gas bypass. Negative SHC value indicates that the air entering
the coil is being heated at 100% gas bypass. The P Series innovative modulating valve system will reduce the gas bypass as
required to meet the supply air setpoint with minimal change in
latent capacity. The space will NOT be overheated and the unit
will provide variable SHC to meet the space load.

87

Performance data (cont)


COOLING CAPACITIES (cont)
48/50P2,P3,P4,P5075 (75 TON) HIGH-CAPACITY COIL STANDARD MODE
Evaporator Air Quantity Cfm
Temp (F)
14,000
17,500
21,000
Air Entering
Condenser
Evaporator Air Ewb (F)
(Edb)
75
72
67
62
57
75
72
67
62
57
75
72
67
TC
912 868 796 732 674 960 913 841 773 721 992 944 871
SHC
376 425 505 584 657 400 461 560 658 721 423 493 611
75
kW
51.6 50.4 48.4 46.7 45.3 52.9 51.5 49.5 47.8 46.5 53.8 52.4 50.3
BF
0.00 0.09 0.02 0.02 0.02 0.00 0.06 0.03 0.02 0.12 0.10 0.05 0.04
TC
885 837 776 714 660 928 884 819 752 708 958 913 847
SHC
363 413 495 575 649 389 449 550 649 708 411 482 601
85
kW
56.5 55.2 53.3 51.7 50.4 57.7 56.4 54.4 52.6 51.6 58.6 57.2 55.3
BF
0.00 0.05 0.03 0.01 0.03 0.14 0.05 0.03 0.02 0.13 0.08 0.05 0.03
TC
858 809 759 698 643 901 861 793 735 693 931 889 825
SHC
352 402 487 567 636 379 441 540 643 693 402 474 592
95
kW
62.2 60.8 59.3 57.7 56.5 63.5 62.3 60.3 58.8 57.7 64.5 63.2 61.3
BF
0.00 0.04 0.03 0.02 0.04 0.11 0.05 0.03 0.01 0.15 0.07 0.05 0.03
TC
835 795 730 676 623 875 834 767 709 673 903 862 796
SHC
344 396 476 555 614 370 430 529 626 673 392 463 580
105
kW
69.2 68.0 66.1 65.2 63.6 70.7 69.5 67.4 66.2 65.0 71.8 70.6 68.7
BF
0.00 0.05 0.02 0.02 0.08 0.09 0.05 0.02 0.02 0.17 0.07 0.05 0.03
TC
804 766 701 645 596 840 799 735 677 648 865 826 760
SHC
334 384 463 540 596 358 418 515 611 648 379 450 565
115
kW
77.7 76.8 74.5 75.6 74.1 79.5 78.3 76.4 75.8 74.9 80.7 79.8 78.3
BF
0.00 0.05 0.02 0.02 0.09 0.07 0.04 0.02 0.02 0.21 0.06 0.04 0.03

24,500
62
803
724
48.5
0.04
786
716
53.6
0.04
763
705
59.7
0.04
733
690
67.0
0.04
699
673
76.7
0.04

57
767
767
47.7
0.22
752
752
52.7
0.23
735
735
58.8
0.25
714
714
66.1
0.27
687
687
75.8
0.30

75
1016
444
54.4
0.07
980
431
59.3
0.07
954
423
65.3
0.07
922
412
72.6
0.06
884
399
82.1
0.06

72
967
525
53.0
0.05
938
514
57.9
0.05
913
505
64.0
0.05
881
493
71.3
0.05
843
480
80.8
0.05

67
892
659
50.9
0.04
869
650
55.9
0.04
845
641
62.0
0.04
813
628
69.3
0.04
777
614
79.0
0.04

62
823
785
49.1
0.05
802
774
54.1
0.06
777
760
60.0
0.06
751
744
67.3
0.07
719
709
75.3
0.12

57
805
805
48.7
0.30
787
787
53.7
0.31
769
769
59.8
0.33
746
746
67.1
0.35
718
718
76.5
0.37

48/50P2,P3,P4,P5075 (75 TON) HIGH-CAPACITY COIL STANDARD MODE


(cont)
Evaporator Air Quantity Cfm
Temp (F)
28,000
30,000
Air Entering
Condenser
Evaporator Air Ewb (F)
(Edb)
75
72
67
62
57
75
72
67
62
57
TC
1034 985 909 839 836 1042 993 916 853 851
SHC
463 555 707 833 836 473 571 733 849 851
75
kW
54.9 53.5 51.4 49.6 49.5 55.2 53.8 51.6 50.0 49.9
BF
0.08 0.06 0.05 0.09 0.36 0.08 0.06 0.05 0.13 0.39
TC
1001 955 885 817 816 1009 963 892 831 829
SHC
452 544 698 817 816 463 561 724 820 829
85
kW
59.8 58.5 56.4 54.5 54.5 60.1 58.7 56.6 55.0 54.9
BF
0.07 0.06 0.05 0.10 0.38 0.08 0.06 0.05 0.17 0.41
TC
973 929 859 799 797 981 936 867 812 810
SHC
443 535 687 796 797 453 552 713 806 810
95
kW
65.9 64.6 62.5 60.6 60.6 66.2 64.8 62.8 61.0 61.0
BF
0.07 0.06 0.05 0.13 0.39 0.07 0.06 0.05 0.18 0.42
TC
938 895 827 772 772 945 901 833 784 785
SHC
431 523 674 767 772 442 539 699 784 785
105
kW
73.3 71.9 69.9 67.6 67.9 73.6 72.2 70.2 68.1 68.3
BF
0.07 0.05 0.05 0.16 0.41 0.07 0.06 0.05 0.20 0.44
898 856 789 742 743 905 862 794 756 755
TC
SHC
418 510 659 742 743 429 526 684 756 755
115
kW
83.0 81.6 80.0 76.5 77.3 83.4 82.0 80.0 77.6 77.7
BF
0.07 0.05 0.05 0.18 0.43 0.07 0.06 0.05 0.22 0.46
LEGEND
3. SHC is based on 80 F edb temperature of air entering evaporator
coil.
48/50P3,P5 units only.
Below 80 F edb, subtract (corr factor x cfm) from SHC.
Above 80 F edb, add (corr factor x cfm) to SHC.
BF Bypass Factor
kW
Compressor Motor Power Input
Edb Entering Dry Bulb
SHC Sensible Heat Cap. (1000 Btuh)
Ewb Entering Wet Bulb
TC
Total Cap. (1000 Btuh) Gross
ENTERING AIR DRY-BULB TEMP (F)
79
78
77
76
75
under 75
NOTES:
BF
1. Direct interpolation is permissible. Do not extrapolate.
81
82
83
84
85
over 85
2. The following formulas may be used:
Correction Factor
sensible capacity (Btuh)
.05
1.04
2.09
3.14
4.18
5.22
tldb = tedb
Use formula
.10
0.99
1.98
2.97
3.96
4.95
1.10 x cfm
.20
0.88
1.76
2.64
3.52
4.40 shown below
tlwb = Wet-bulb temperature corresponding to enthalpy of air
leaving evaporator coil (hlwb).
Interpolation is permissible.
Correction Factor = 1.10 x (1 BF) x (edb 80).
total capacity (Btuh)
hlwb = hewb
4.
Cooling
capacities are gross and do not include deduction for indoor
4.5 x cfm
fan motor heat.
Where: hewb = Enthalpy of air entering evaporator coil.

88

COOLING CAPACITIES (cont)


48/50P2,P3,P4,P5075 (75 TON) HIGH-CAPACITY COIL SUBCOOL MODE
Evaporator Air Quantity Cfm
Temp (F)
14,000
17,500
21,000
Air Entering
Condenser
Evaporator Air Ewb (F)
(Edb)
75
72
67
62
57
75
72
67
62
57
75
72
67
TC
871 825 758 693 647 913 869 799 726 674 946 896 837
SHC
277 330 421 508 606 296 363 472 572 660 317 391 530
75
57.3 56.1 54.4 53.0 52.4 58.6 57.3 55.5 53.5 52.5 59.5 58.1 56.5
kW
BF
0.00 0.02 0.02 0.02 0.03 0.07 0.04 0.03 0.03 0.09 0.07 0.05 0.04
TC
836 794 741 680 616 876 834 766 717 650 907 866 792
250 306 411 502 580 268 336 447 569 636 289 369 493
SHC
85
kW
62.1 61.0 59.7 58.6 57.2 63.3 62.1 60.3 59.3 57.5 64.2 63.0 61.0
BF
0.00 0.02 0.02 0.02 0.04 0.07 0.04 0.03 0.03 0.10 0.07 0.05 0.04
TC
798 769 708 649 592 836 804 729 684 619 861 820 765
SHC
222 291 387 480 559 238 317 420 546 607 255 334 477
95
kW
67.7 67.0 65.6 64.6 64.0 68.9 68.0 65.9 65.1 63.3 69.7 68.4 67.0
0.03 0.02 0.02 0.02 0.05 0.07 0.04 0.03 0.03 0.12 0.07 0.05 0.04
BF
756 729 671 615 565 798 752 702 647 586 818 776 724
TC
SHC
192 263 362 456 533 214 277 405 519 576 226 304 448
105
74.2 73.5 72.6 72.1 72.0 75.4 74.1 73.0 72.3 70.7 76.1 74.8 73.4
kW
BF
0.03 0.02 0.02 0.02 0.07 0.06 0.04 0.03 0.04 0.13 0.07 0.05 0.05
TC
711 688 631 578 533 750 706 646 607 574 770 728 680
SHC
162 235 334 429 504 183 247 362 492 568 194 272 418
115
kW
82.0 81.7 81.0 81.0 81.3 83.0 81.8 80.6 80.9 80.9 83.6 82.4 81.4
0.02 0.02 0.02 0.02 0.09 0.06 0.04 0.03 0.04 0.15 0.07 0.05 0.05
BF

24,500
62
761
644
54.5
0.05
743
633
59.9
0.05
706
606
65.5
0.05
670
580
72.5
0.05
629
551
81.0
0.06

57
717
717
53.5
0.17
689
689
58.4
0.18
657
657
64.1
0.20
623
623
71.3
0.22
586
586
79.8
0.23

75
966
333
60.2
0.08
923
302
64.8
0.08
880
271
70.3
0.08
833
239
76.6
0.08
781
205
84.0
0.08

72
919
421
58.8
0.06
880
392
63.5
0.06
842
365
69.1
0.06
796
333
75.4
0.06
744
297
82.8
0.06

67
847
561
56.8
0.06
812
539
61.6
0.06
782
520
67.4
0.06
739
490
73.8
0.06
694
460
81.7
0.06

62
773
697
54.8
0.07
747
677
59.9
0.07
711
647
65.5
0.08
671
610
72.0
0.10
631
573
80.1
0.12

57
753
753
54.4
0.26
741
741
60.0
0.27
708
708
65.7
0.28
674
674
72.7
0.30
635
635
81.0
0.31

48/50P2,P3,P4,P5075 (75 TON) HIGH-CAPACITY COIL SUBCOOL MODE


(cont)
Evaporator Air Quantity Cfm
Temp (F)
28,000
30,000
Air Entering
Condenser
Evaporator Air Ewb (F)
(Edb)
75
72
67
62
57
75
72
67
62
57
TC
983 936 862 796 783 990 944 869 806 797
SHC
351 449 611 755 783 360 465 636 777 797
75
kW
60.7 59.4 57.3 55.5 55.2 60.9 59.6 57.5 55.8 55.6
BF
0.09 0.08 0.07 0.10 0.33 0.10 0.08 0.08 0.13 0.36
TC
939 898 826 764 768 974 902 840 790 761
SHC
320 422 583 721 768 369 434 615 762 761
85
kW
65.4 64.1 62.0 60.3 60.6 69.7 64.2 62.4 61.2 60.1
BF
0.09 0.08 0.07 0.11 0.34 0.12 0.08 0.08 0.14 0.37
TC
895 852 786 747 733 932 856 800 755 747
SHC
289 388 554 706 733 346 395 586 729 747
95
kW
70.8 69.5 67.6 66.7 66.3 75.8 69.6 68.0 66.9 66.7
BF
0.09 0.08 0.07 0.13 0.35 0.12 0.08 0.08 0.15 0.38
TC
846 806 750 709 697 850 812 755 717 709
SHC
251 356 532 671 697 273 371 555 693 709
105
kW
77.0 75.8 74.2 73.2 73.0 77.2 76.0 74.4 73.4 73.2
BF
0.10 0.08 0.07 0.14 0.36 0.10 0.08 0.08 0.16 0.40
TC
794 755 704 668 658 802 761 708 676 669
SHC
220 323 500 634 658 222 338 523 656 669
115
kW
84.4 83.2 81.9 81.3 81.2 84.6 83.4 82.0 81.4 81.4
BF
0.09 0.08 0.07 0.16 0.38 0.10 0.08 0.08 0.18 0.41
LEGEND
48/50P3,P5 units only.
BF Bypass Factor
kW
Compressor Motor Power Input
Edb Entering Dry Bulb
SHC Sensible Heat Cap. (1000 Btuh)
Ewb Entering Wet Bulb
TC
Total Cap. (1000 Btuh) Gross
NOTES:
1. The SHC is based on 80 F edb temperature of air entering evaporator coil. For edb temperatures other than 80 F, adjust SHC by
multiplying the correction factor and the cfm and then adding or
subtracting the value from the SHC.

2. Interpolation is permissible.
3. Correction Factor = 1.10 x (1 BF) x (edb 80).
4. Cooling capacities are gross and do not include deduction for
indoor fan motor heat.
5. SHC values provided are in subcooling mode with the gas bypass
valve closed and reflect the maximum SHC in subcooling mode.
The P Series innovative modulating valve system can reduce SHC
as needed to meet the supply air set point requirement with minimal change in latent capacity. This will provide variable SHC to
meet the space load.

89

Performance data (cont)


COOLING CAPACITIES (cont)
48/50P2,P3,P4,P5075 (75 TON) HIGH-CAPACITY COIL HOT GAS REHEAT MODE
Air Entering Evaporator Ewb (F)
Temp (F)
75 Dry Bulb
75 Dry Bulb
Air Ent
62.5 Wet Bulb (50% RH)
65.3 Wet Bulb (60% RH)
Condenser
Air Entering Evaporator Cfm
(Edb)
14,000
17,500
21,000
24,500
28,000
30,000
14,000
17,500
21,000
24,500
28,000
TC
293
314
328
337
344
347
310
331
345
354
361
SHC
22
51
83
117
151
170
-45
-27
-6
17
42
80
kW
57.6
57.3
57.2
57.3
57.4
57.4
58.6
58.4
58.3
58.4
58.5
BF
0.02
0.03
0.05
0.06
0.07
0.08
0.02
0.03
0.05
0.06
0.07
TC
300
321
335
344
351
354
317
338
351
361
368
SHC
26
55
87
120
154
174
-41
-23
-2
21
45
75
kW
55.7
55.5
55.4
55.5
55.6
55.7
56.8
56.6
56.7
56.8
56.8
BF
0.02
0.03
0.05
0.06
0.07
0.08
0.02
0.03
0.05
0.06
0.07
TC
306
327
340
350
357
360
322
343
357
367
374
SHC
30
59
90
124
158
177
-38
-20
1
24
49
70
kW
53.9
53.8
53.9
54.0
54.1
54.2
55.2
55.0
55.1
55.3
55.4
BF
0.02
0.03
0.05
0.06
0.07
0.08
0.02
0.03
0.05
0.06
0.07
TC
301
319
331
340
345
348
316
334
346
354
361
SHC
29
57
89
121
155
174
-39
-22
-1
21
46
60
kW
56.2
56.4
56.6
56.9
57.1
57.2
57.7
57.9
58.2
58.5
58.7
BF
0.02
0.03
0.05
0.06
0.07
0.08
0.02
0.03
0.05
0.06
0.07
TC
312
330
342
350
357
359
326
345
357
366
372
SHC
35
63
95
127
161
180
-33
-16
5
28
52
50
kW
52.8
53.2
53.6
53.9
54.2
54.3
54.4
54.8
55.2
55.5
55.8
BF
0.02
0.03
0.05
0.06
0.07
0.08
0.02
0.03
0.05
0.06
0.07
TC
319
338
350
359
366
369
334
353
366
375
382
SHC
40
69
99
132
166
185
-28
-10
10
33
57
40
kW
50.1
50.6
51.2
51.5
51.8
52.0
51.8
52.3
52.8
53.2
53.5
BF
0.02
0.03
0.05
0.06
0.07
0.08
0.02
0.03
0.05
0.06
0.07

30,000
364
56
58.6
0.08
371
60
56.9
0.08
377
63
55.5
0.08
363
60
58.8
0.08
375
66
55.9
0.08
385
71
53.6
0.08

48/50P2,P3,P4,P5075 (75 TON) HIGH-CAPACITY COIL HOT GAS REHEAT MODE (cont)
Air Entering Evaporator Ewb (F)
Temp (F)
75 Dry Bulb
75 Dry Bulb
Air Ent
68 Wet Bulb (70% RH)
70.5 Wet Bulb (80% RH)
Condenser
Air Entering Evaporator Cfm
(Edb)
14,000
17,500
21,000
24,500
28,000
30,000
14,000
17,500
21,000
24,500
28,000
TC
327
348
362
371
378
381
342
363
377
387
394
SHC
-111
-104
-93
-80
-65
-56
-174
-176
-175
-171
-165
80
kW
60.0
59.7
59.6
59.8
59.9
60.0
61.4
61.1
61.1
61.3
61.5
BF
0.02
0.04
0.05
0.07
0.08
0.09
0.00
0.07
0.07
0.09
0.10
TC
333
354
368
377
385
388
348
370
384
393
401
SHC
-107
-100
-90
-77
-62
-52
-170
-173
-172
-168
-161
75
kW
58.2
57.9
58.1
58.2
58.3
58.4
59.6
59.4
59.6
59.7
59.8
BF
0.02
0.04
0.05
0.07
0.08
0.09
0.00
0.07
0.07
0.09
0.10
TC
339
360
374
383
391
395
354
375
390
400
409
SHC
-104
-97
-87
-73
-58
-49
-167
-170
-168
-164
-158
70
kW
56.6
56.5
56.6
56.7
56.8
56.9
58.1
57.9
58.1
58.2
58.4
BF
0.02
0.04
0.05
0.07
0.08
0.09
0.00
0.07
0.07
0.09
0.10
TC
330
349
361
370
376
379
344
363
376
384
391
SHC
-106
-99
-89
-76
-61
-52
-169
-172
-171
-167
-161
60
kW
59.4
59.6
59.9
60.2
60.4
60.5
61.2
61.4
61.6
61.9
62.2
BF
0.02
0.04
0.05
0.07
0.08
0.09
0.00
0.06
0.07
0.09
0.10
TC
341
360
372
381
388
391
355
375
387
396
403
SHC
-99
-93
-83
-70
-55
-46
-162
-165
-165
-161
-155
50
kW
56.2
56.5
56.9
57.3
57.5
57.6
58.0
58.3
58.6
59.0
59.2
BF
0.02
0.04
0.05
0.07
0.08
0.09
0.00
0.07
0.07
0.09
0.10
TC
349
369
382
392
400
404
364
384
398
409
417
SHC
-94
-88
-78
-64
-49
-40
-157
-160
-159
-155
-149
40
kW
53.6
54.0
54.5
54.9
55.2
55.3
55.3
55.8
56.2
56.6
56.9
BF
0.02
0.04
0.05
0.07
0.08
0.09
0.00
0.07
0.07
0.09
0.10

30,000
398
-160
61.5
0.11
405
-157
59.9
0.11
413
-153
58.5
0.11
394
-157
62.3
0.11
407
-151
59.3
0.11
421
-144
57.0
0.11

LEGEND
BF Bypass Factor
RH
Relative Humidity
Edb Entering Dry Bulb
SHC Sensible Heat Cap. (1000 Btuh)
Ewb Entering Wet Bulb
TC
Total Cap. (1000 Btuh) Gross
kW Compressor Motor Power
Input
NOTES:
1. The SHC is based on 75 F edb temperature of air entering evaporator coil. For edb temperatures other than 75 F, adjust SHC by
multiplying the correction factor and the cfm and then adding or
subtracting the value from the SHC.
2. Interpolation is permissible.
3. Correction Factor = 1.10 x (1 BF) x (edb 75).
4. Cooling capacities are gross and do not include deduction for
indoor fan motor heat.
5. Capacity table includes impact of outdoor fan staging at temperatures below 75 F.

90

6. SHC values provided reflect maximum reheat values with 100%


gas bypass. Negative SHC value indicates that the air entering
the coil is being heated at 100% gas bypass. The P Series innovative modulating valve system will reduce the gas bypass as
required to meet the supply air setpoint with minimal change in
latent capacity. The space will NOT be overheated and the unit
will provide variable SHC to meet the space load.

COOLING CAPACITIES (cont)


48/50P2,P3,P4,P5090 (90 TON) STANDARD CAPACITY COIL STANDARD MODE
Evaporator Air Quantity Cfm
Temp (F)
18,000
22,500
27,000
Air Entering
Condenser
Evaporator Air Ewb (F)
(Edb)
75
72
67
62
57
75
72
67
62
57
75
72
67
TC
1118 1070 985 903 822 1173 1118 1032 950 884 1204 1152 1066
SHC
460 513 614 709 790 474 553 674 790 858 501 590 729
75
kW
61.5 60.5 59.0 57.8 56.7 62.6 61.5 59.9 58.6 57.4 63.3 62.2 60.6
BF
0.00 0.00 0.13 0.10 0.11 0.00 0.21 0.13 0.11 0.21 0.00 0.18 0.14
TC
1086 1037 954 873 791 1135 1083 998 917 847 1165 1112 1030
SHC
444 501 600 694 759 461 540 659 775 847 489 576 714
85
kW
68.1 67.1 65.8 64.6 63.3 69.1 68.1 66.6 65.4 64.2 69.8 68.7 67.2
BF
0.00 0.00 0.13 0.10 0.10 0.00 0.19 0.13 0.11 0.19 0.30 0.16 0.14
TC
1050 1001 920 841 763 1093 1044 961 882 827 1122 1073 990
SHC
430 488 585 678 748 450 526 644 758 810 475 561 699
95
kW
75.7 74.7 73.6 72.3 71.3 76.7 75.8 74.4 73.1 72.1 77.4 76.5 75.0
BF
0.00 0.26 0.12 0.09 0.12 0.00 0.17 0.12 0.11 0.25 0.24 0.16 0.13
TC
1010 961 881 806 734 1048 1000 919 842 791 1075 1026 946
SHC
411 472 568 663 729 436 510 626 739 791 460 546 681
105
kW
84.5 83.7 82.4 81.3 81.1 85.4 84.6 83.2 82.2 81.8 86.1 85.1 83.8
BF
0.00 0.20 0.11 0.08 0.14 0.00 0.15 0.12 0.11 0.24 0.21 0.15 0.13
TC
963 914 838 768 713 997 950 872 797 758 1021 974 896
SHC
391 454 550 647 693 420 492 607 718 758 443 527 661
115
kW
94.5 93.7 93.5 92.2 92.2 95.3 94.5 93.9 94.0 93.5 96.0 95.2 94.2
BF
0.00 0.16 0.10 0.08 0.20 0.24 0.14 0.11 0.11 0.28 0.18 0.14 0.13

48/50P2,P3,P4,P5090 (90 TON) STANDARD


CAPACITY COIL STANDARD MODE (cont)
Evaporator Air Quantity
Cfm
Temp (F)
Air Entering
36,000
Condenser
Evaporator Air Ewb (F)
(Edb)
75
72
67
62
57
TC
1251 1195 1109 1023 1004
SHC
547 656 831 983 1004
75
kW
64.3 63.2 61.4 59.9 59.6
BF
0.22 0.17 0.16 0.18 0.40
TC
1208 1153 1070 986 974
SHC
534 641 816 962 974
85
kW
70.7 69.6 68.1 66.7 66.4
BF
0.21 0.17 0.16 0.19 0.42
TC
1161 1110 1027 948 942
SHC
519 626 800 929 942
95
kW
78.3 77.3 75.8 74.4 74.3
BF
0.20 0.17 0.16 0.22 0.44
TC
1110 1061 980 908 905
SHC
503 609 781 899 905
105
kW
87.0 86.1 84.6 83.2 83.2
BF
0.19 0.17 0.16 0.24 0.46
1052 1005 927 867 864
TC
SHC
485 589 762 860 864
115
kW
96.8 96.0 94.8 94.2 94.3
BF
0.18 0.17 0.16 0.27 0.48

31,500
62
981
863
59.2
0.13
947
846
66.0
0.13
909
828
73.7
0.13
867
807
82.8
0.13
821
784
94.2
0.14

57
922
922
58.2
0.25
899
899
65.1
0.28
873
873
72.9
0.30
839
839
82.0
0.33
802
802
93.8
0.36

75
1231
525
63.9
0.25
1187
512
70.3
0.22
1144
498
77.9
0.21
1095
482
86.6
0.19
1039
465
96.5
0.18

72
1175
624
62.8
0.17
1137
609
69.3
0.17
1093
594
76.9
0.16
1046
578
85.7
0.16
992
560
95.6
0.15

67
1090
781
61.1
0.15
1052
766
67.7
0.15
1011
750
75.4
0.15
965
732
84.2
0.14
914
712
94.5
0.14

62
1005
928
59.6
0.15
970
911
66.4
0.16
930
888
74.1
0.16
886
859
82.9
0.18
839
833
94.1
0.19

57
970
970
58.9
0.34
942
942
65.8
0.36
910
910
73.7
0.38
874
874
82.6
0.40
837
837
94.0
0.43

LEGEND
48/50P3,P5 units only.
BF Bypass Factor
kW
Compressor Motor Power Input
Edb Entering Dry Bulb
SHC Sensible Heat Cap. (1000 Btuh)
Ewb Entering Wet Bulb
TC
Total Cap. (1000 Btuh) Gross
NOTES:
1. Direct interpolation is permissible. Do not extrapolate.
2. The following formulas may be used:
sensible capacity (Btuh)
tldb = tedb
1.10 x cfm
tlwb = Wet-bulb temperature corresponding to enthalpy of air
leaving evaporator coil (hlwb).
hlwb =

hewb

total capacity (Btuh)


4.5 x cfm

Where: hewb = Enthalpy of air entering evaporator coil.


3. SHC is based on 80 F edb temperature of air entering evaporator coil.
Below 80 F edb, subtract (corr factor x cfm) from SHC.
Above 80 F edb, add (corr factor x cfm) to SHC.

BF

79
81

.05
.10
.20

1.04
0.99
0.88

ENTERING AIR DRY-BULB TEMP (F)


78
77
76
75
under 75
82
83
84
85
over 85
Correction Factor
2.09
3.14
4.18
5.22
Use formula
1.98
2.97
3.96
4.95
1.76
2.64
3.52
4.40 shown below

Interpolation is permissible.
Correction Factor = 1.10 x (1 BF) x (edb 80).
4. Cooling capacities are gross and do not include deduction for indoor fan motor heat.

91

Performance data (cont)


COOLING CAPACITIES (cont)
48/50P2,P3,P4,P5090 (90 TON) STANDARD CAPACITY COIL SUBCOOL MODE
Evaporator Air Quantity Cfm
Temp (F)
18,000
22,500
27,000
Air Entering
Condenser
Evaporator Air Ewb (F)
(Edb)
75
72
67
62
57
75
72
67
62
57
75
72
67
TC
1075 1017 922 863 788 1154 1072 1003 915 836 1171 1135 1017
SHC
396 454 541 656 744 450 493 629 736 819 452 553 658
75
61.1 60.1 58.5 58.1 57.2 62.8 61.1 60.3 58.8 57.7 63.0 62.5 60.2
kW
BF
0.00 0.05 0.09 0.10 0.11 0.03 0.10 0.12 0.12 0.18 0.09 0.12 0.14
TC
1052 964 884 828 752 1080 1013 933 876 807 1117 1083 995
387 413 513 629 712 391 449 570 707 791 414 516 649
SHC
85
kW
68.2 66.3 64.9 64.9 64.0 68.5 67.3 65.8 65.5 64.6 69.2 68.8 67.3
BF
0.00 0.06 0.09 0.10 0.11 0.04 0.10 0.12 0.12 0.19 0.09 0.13 0.14
TC
977 950 868 790 718 1026 972 914 835 771 1080 1006 946
SHC
327 413 508 600 686 354 423 564 677 756 396 456 615
95
kW
74.7 74.6 73.6 72.8 71.9 75.7 74.6 74.1 73.3 72.4 77.0 75.3 74.6
0.00 0.06 0.09 0.10 0.11 0.04 0.10 0.12 0.12 0.20 0.09 0.13 0.14
BF
TC
924 839 823 750 689 991 943 865 790 734 1000 972 894
SHC
291 315 476 570 656 337 410 529 645 721 336 440 579
105
83.0 81.6 82.5 81.9 81.1 84.5 83.8 82.9 82.2 81.5 84.5 84.2 83.3
kW
BF
0.00 0.06 0.09 0.10 0.15 0.05 0.10 0.12 0.12 0.22 0.09 0.13 0.14
TC
868 848 774 708 648 931 886 812 742 694 956 912 838
SHC
253 342 442 544 617 297 371 493 611 682 313 399 540
115
kW
92.8 93.3 92.8 92.4 91.8 94.2 93.7 93.0 92.6 92.0 94.5 94.0 93.3
BF
0.00 0.06 0.09 0.10 0.16 0.05 0.10 0.12 0.13 0.24 0.10 0.13 0.14

31,500
62
925
782
58.6
0.15
910
778
65.9
0.15
866
746
73.6
0.15
819
712
82.5
0.15
769
675
92.7
0.16

57
883
883
58.4
0.26
844
844
65.1
0.26
808
808
73.0
0.28
770
770
82.0
0.30
728
728
92.5
0.31

75
1201
475
63.6
0.12
1144
436
69.8
0.12
1086
396
77.0
0.12
1041
372
85.6
0.12
974
329
94.8
0.13

72
1142
563
62.4
0.15
1088
525
68.7
0.15
1053
508
76.5
0.15
993
468
84.6
0.15
930
426
94.2
0.15

67
1045
707
60.7
0.16
996
673
67.0
0.16
944
637
74.2
0.16
916
625
83.5
0.16
858
586
93.4
0.16

62
952
846
59.1
0.17
935
841
66.4
0.18
890
807
73.9
0.18
843
773
82.8
0.19
790
728
92.9
0.20

57
923
923
59.0
0.33
887
887
65.7
0.34
849
849
73.5
0.35
807
807
82.4
0.37
762
762
92.7
0.39

48/50P2,P3,P4,P5090 (90 TON) STANDARD


CAPACITY COIL SUBCOOL MODE (cont)
Evaporator Air Quantity
Cfm
Temp (F)
Air Entering
36,000
Condenser
Evaporator Air Ewb (F)
(Edb)
75
72
67
62
57
TC
1209 1164 1068 972 932
SHC
481 594 757 903 932
75
kW
63.8 62.9 61.2 59.5 58.7
BF
0.15 0.17 0.18 0.20 0.39
TC
1165 1109 1041 929 923
SHC
456 555 745 869 923
85
kW
70.2 69.1 68.1 65.8 66.2
BF
0.15 0.17 0.18 0.21 0.40
TC
1105 1051 963 908 882
SHC
415 516 683 863 882
95
kW
77.4 76.3 74.6 74.2 73.9
BF
0.15 0.17 0.18 0.21 0.41
TC
1041 990 932 860 838
SHC
373 475 669 815 838
105
kW
85.5 84.4 83.8 82.9 82.7
BF
0.15 0.17 0.18 0.23 0.43
TC
973 926 872 810 791
SHC
329 433 629 767 791
115
kW
94.6 93.8 93.6 93.0 92.9
BF
0.15 0.17 0.18 0.25 0.44
LEGEND
48/50P3,P5 units only.
BF Bypass Factor
kW
Compressor Motor Power Input
Edb Entering Dry Bulb
SHC Sensible Heat Cap. (1000 Btuh)
Ewb Entering Wet Bulb
TC
Total Cap. (1000 Btuh) Gross
NOTES:
1. The SHC is based on 80 F edb temperature of air entering evaporator coil. For edb temperatures other than 80 F, adjust SHC by
multiplying the correction factor and the cfm and then adding or
subtracting the value from the SHC.

92

2. Interpolation is permissible.
3. Correction Factor = 1.10 x (1 BF) x (edb 80).
4. Cooling capacities are gross and do not include deduction for
indoor fan motor heat.
5. SHC values provided are in subcooling mode with the gas bypass
valve closed and reflect the maximum SHC in subcooling mode.
The P Series innovative modulating valve system can reduce SHC
as needed to meet the supply air set point requirement with minimal change in latent capacity. This will provide variable SHC to
meet the space load.

COOLING CAPACITIES (cont)


48/50P2,P3,P4,P5090 (90 TON) STANDARD CAPACITY COIL HOT GAS REHEAT MODE
Air Entering Evaporator Ewb (F)
Temp (F)
75 Dry Bulb
Air Ent
62.5 Wet Bulb (50% RH)
Condenser
Air Entering Evaporator Cfm
(Edb)
18,000
22,500
27,000
31,500
36,000
18,000
TC
362
390
410
425
436
385
SHC
60
95
131
166
202
-9
80
kW
64.0
63.6
63.5
63.4
63.4
65.3
BF
0.09
0.12
0.14
0.16
0.18
0.08
TC
371
400
421
436
448
395
SHC
66
101
137
173
209
-3
75
kW
61.6
61.3
61.2
61.3
61.3
63.0
BF
0.09
0.12
0.14
0.16
0.18
0.08
TC
377
406
426
440
452
400
SHC
71
106
142
178
214
1
70
kW
61.6
61.4
61.4
61.6
61.8
63.1
BF
0.09
0.12
0.14
0.16
0.18
0.08
TC
389
418
438
453
464
411
SHC
82
117
154
190
228
14
60
kW
59.4
59.5
60.0
60.4
60.7
61.2
BF
0.09
0.12
0.14
0.16
0.18
0.08
TC
397
425
445
459
470
419
SHC
91
127
165
203
241
24
50
kW
58.4
59.1
59.7
60.2
60.6
60.7
BF
0.09
0.12
0.14
0.16
0.18
0.08
TC
411
441
462
477
488
434
SHC
101
139
177
215
253
36
40
kW
55.3
56.0
56.6
57.1
57.5
57.5
BF
0.09
0.12
0.14
0.17
0.18
0.08

48/50P2,P3,P4,P5090 (90 TON) STANDARD CAPACITY COIL HOT GAS REHEAT MODE (cont)
Air Entering Evaporator Ewb (F)
Temp (F)
75 Dry Bulb
Air Ent
68 Wet Bulb (70% RH)
Condenser
Air Entering Evaporator Cfm
(Edb)
18,000
22,500
27,000
31,500
36,000
18,000
TC
409
440
461
477
490
432
SHC
-76
-64
-51
-35
-15
-139
80
kW
66.7
66.2
66.2
66.2
66.3
68.2
BF
0.06
0.10
0.13
0.15
0.17
0.00
TC
418
450
472
488
501
441
SHC
-68
-55
-40
-23
-5
-130
75
kW
64.5
64.3
64.4
64.6
64.7
66.3
BF
0.06
0.10
0.13
0.15
0.17
0.00
TC
423
453
475
490
502
444
SHC
-63
-49
-34
-16
2
-124
70
kW
64.8
64.9
65.1
65.4
65.6
66.8
BF
0.06
0.10
0.13
0.15
0.17
0.00
TC
434
464
486
501
513
455
SHC
-50
-35
-17
2
23
-109
60
kW
63.4
63.8
64.2
64.5
64.8
65.6
BF
0.06
0.10
0.13
0.15
0.17
0.00
TC
440
470
491
505
516
461
SHC
-38
-20
0
21
43
-93
50
kW
63.1
63.6
64.2
64.6
65.0
65.4
BF
0.06
0.10
0.13
0.15
0.17
0.01
TC
456
487
509
525
537
477
SHC
-26
-9
11
31
52
-84
40
kW
59.7
60.3
60.8
61.3
61.7
61.9
BF
0.05
0.10
0.13
0.15
0.17
0.00

LEGEND
BF Bypass Factor
RH
Relative Humidity
Edb Entering Dry Bulb
SHC Sensible Heat Cap. (1000 Btuh)
Ewb Entering Wet Bulb
TC
Total Cap. (1000 Btuh) Gross
kW Compressor Motor Power
Input

75 Dry Bulb
65.3 Wet Bulb (60% RH)
22,500
415
14
64.9
0.11
425
21
62.7
0.11
430
25
62.9
0.11
441
39
61.6
0.11
448
51
61.3
0.11
464
63
58.1
0.11

27,000
436
39
64.7
0.14
446
47
62.6
0.14
451
50
63.0
0.14
462
66
62.1
0.14
468
80
61.9
0.14
485
91
58.7
0.14

31,500
451
63
64.8
0.16
462
73
62.7
0.16
465
78
63.4
0.16
477
93
62.4
0.16
482
109
62.4
0.16
501
120
59.2
0.16

36,000
463
90
64.7
0.18
474
100
62.9
0.18
477
105
63.7
0.18
488
122
62.8
0.18
493
139
62.8
0.18
513
150
59.6
0.18

31,500
502
-121
67.9
0.12
513
-110
66.4
0.12
514
-102
67.3
0.12
524
-80
66.5
0.13
527
-57
66.8
0.13
547
-50
63.3
0.12

36,000
514
-112
68.0
0.15
526
-101
66.5
0.15
527
-94
67.4
0.15
536
-70
66.7
0.15
538
-47
67.1
0.15
559
-38
63.6
0.15

75 Dry Bulb
70.5 Wet Bulb (80% RH)
22,500
463
-134
67.8
0.04
473
-125
66.1
0.04
476
-119
66.9
0.04
487
-100
65.9
0.05
491
-82
65.9
0.05
509
-74
62.4
0.04

27,000
485
-129
67.8
0.09
496
-118
66.2
0.09
498
-111
67.1
0.09
508
-91
66.2
0.09
512
-70
66.4
0.10
531
-62
62.9
0.09

6. SHC values provided reflect maximum reheat values with 100%


gas bypass. Negative SHC value indicates that the air entering
the coil is being heated at 100% gas bypass. The P Series innovative modulating valve system will reduce the gas bypass as
required to meet the supply air setpoint with minimal change in
latent capacity. The space will NOT be overheated and the unit
will provide variable SHC to meet the space load.

NOTES:
1. The SHC is based on 75 F edb temperature of air entering evaporator coil. For edb temperatures other than 75 F, adjust SHC by
multiplying the correction factor and the cfm and then adding or
subtracting the value from the SHC.
2. Interpolation is permissible.
3. Correction Factor = 1.10 x (1 BF) x (edb 75).
4. Cooling capacities are gross and do not include deduction for
indoor fan motor heat.
5. Capacity table includes impact of outdoor fan staging at temperatures below 75 F.

93

Performance data (cont)


COOLING CAPACITIES (cont)
48/50P2,P3,P4,P5090 (90 TON) HIGH-CAPACITY COIL STANDARD MODE
Evaporator Air Quantity Cfm
Temp (F)
18,000
22,500
27,000
Air Entering
Condenser
Evaporator Air Ewb (F)
(Edb)
75
72
67
62
57
75
72
67
62
57
75
72
67
TC
1177 1117 1025 946 870 1238 1176 1081 999 929 1279 1214 1119
SHC
486 546 648 750 843 512 591 717 843 921 542 633 781
75
kW
63.2 62.0 60.0 58.4 57.0 64.6 63.2 61.2 59.5 58.1 65.4 64.1 62.0
BF
0.00 0.13 0.04 0.03 0.04 0.00 0.08 0.04 0.04 0.13 0.13 0.06 0.05
TC
1138 1081 1000 922 846 1191 1133 1051 971 908 1228 1167 1087
SHC
465 531 636 738 828 496 575 704 830 908 525 616 768
85
kW
69.7 68.4 66.6 65.1 63.8 70.9 69.6 67.8 66.2 64.9 71.7 70.4 68.6
BF
0.00 0.10 0.04 0.03 0.04 0.00 0.07 0.04 0.03 0.13 0.11 0.06 0.05
TC
1100 1050 971 894 819 1151 1092 1018 940 883 1185 1134 1051
SHC
450 518 623 723 810 483 560 690 814 883 510 602 754
95
kW
77.1 76.0 74.4 73.1 71.5 78.3 77.0 75.5 74.1 72.7 79.2 78.0 76.3
BF
0.00 0.08 0.04 0.03 0.05 0.17 0.06 0.04 0.03 0.16 0.10 0.06 0.05
TC
1064 1014 936 858 792 1110 1060 980 900 854 1140 1091 1009
SHC
434 504 607 706 780 469 547 674 794 854 495 586 736
105
kW
85.9 84.9 83.5 82.3 80.5 87.2 86.1 84.6 83.3 82.0 88.0 86.9 85.4
BF
0.00 0.07 0.04 0.02 0.09 0.13 0.06 0.04 0.04 0.19 0.09 0.06 0.05
TC
1019 967 893 816 756 1061 1012 932 855 820 1087 1039 960
SHC
422 486 588 685 756 452 528 654 773 820 477 568 716
115
kW
96.1 94.7 94.2 94.4 92.7 97.4 96.4 95.3 95.2 93.4 98.2 97.2 96.1
BF
0.00 0.05 0.03 0.03 0.10 0.10 0.06 0.04 0.04 0.22 0.08 0.06 0.05

48/50P2,P3,P4,P5090 (90 TON) HIGHCAPACITY COIL STANDARD MODE (cont)


Evaporator Air Quantity
Cfm
Temp (F)
Air Entering
36,000
Condenser
Evaporator Air Ewb (F)
(Edb)
75
72
67
62
57
TC
1331 1267 1169 1081 1069
SHC
593 711 903 1066 1069
75
kW
66.6 65.2 63.0 61.2 61.1
BF
0.10 0.07 0.06 0.10 0.36
TC
1276 1218 1133 1048 1043
SHC
575 692 889 1042 1043
85
kW
72.8 71.5 69.6 67.8 67.7
BF
0.09 0.07 0.06 0.11 0.38
TC
1231 1177 1093 1017 1014
SHC
560 678 873 1007 1014
95
kW
80.3 79.1 77.4 75.6 75.6
BF
0.09 0.07 0.06 0.15 0.40
TC
1182 1129 1047 983 979
SHC
544 661 855 968 979
105
kW
89.1 88.0 86.4 84.8 84.7
BF
0.09 0.07 0.06 0.18 0.42
1126 1073 993 938 937
TC
SHC
526 642 832 938 937
115
kW
99.5 98.3 97.4 95.3 95.3
BF
0.08 0.07 0.06 0.20 0.44

31,500
62
1036
927
60.2
0.05
1005
912
66.9
0.05
971
895
74.8
0.05
930
875
83.9
0.05
882
852
94.4
0.06

57
984
984
59.2
0.22
962
962
65.9
0.24
936
936
73.8
0.26
905
905
83.1
0.28
868
868
94.2
0.31

75
1309
569
66.1
0.10
1255
551
72.3
0.09
1208
535
79.8
0.09
1161
520
88.5
0.08
1108
502
98.8
0.08

72
1246
672
64.7
0.07
1198
655
71.0
0.07
1153
640
78.5
0.06
1104
623
87.1
0.06
1059
605
97.8
0.06

67
1147
842
62.6
0.06
1113
829
69.2
0.06
1075
813
76.9
0.05
1031
797
86.0
0.05
979
776
96.7
0.05

62
1061
1004
60.8
0.07
1028
986
67.4
0.07
994
968
75.2
0.08
952
941
84.2
0.09
910
899
95.0
0.13

57
1031
1031
60.2
0.30
1006
1006
66.9
0.31
979
979
74.8
0.33
946
946
83.9
0.36
906
906
94.8
0.38

LEGEND
48/50P3,P5 units only.
BF Bypass Factor
kW
Compressor Motor Power Input
Edb Entering Dry Bulb
SHC Sensible Heat Cap. (1000 Btuh)
Ewb Entering Wet Bulb
TC
Total Cap. (1000 Btuh) Gross
NOTES:
1. Direct interpolation is permissible. Do not extrapolate.
2. The following formulas may be used:
sensible capacity (Btuh)
tldb = tedb
1.10 x cfm
Wet-bulb temperature corresponding to enthalpy of air
tlwb = leaving evaporator coil (h ).
lwb
hlwb =

hewb

total capacity (Btuh)


4.5 x cfm

Where: hewb = Enthalpy of air entering evaporator coil.


3. SHC is based on 80 F edb temperature of air entering evaporator coil.
Below 80 F edb, subtract (corr factor x cfm) from SHC.
Above 80 F edb, add (corr factor x cfm) to SHC.

BF

79
81

.05
.10
.20

1.04
0.99
0.88

ENTERING AIR DRY-BULB TEMP (F)


78
77
76
75
under 75
82
83
84
85
over 85
Correction Factor
2.09
3.14
4.18
5.22
Use formula
1.98
2.97
3.96
4.95
shown below
1.76
2.64
3.52
4.40

Interpolation is permissible.
Correction Factor = 1.10 x (1 BF) x (edb 80).
4. Cooling capacities are gross and do not include deduction for indoor fan motor heat.

94

COOLING CAPACITIES (cont)


48/50P2,P3,P4,P5090 (90 TON) HIGH-CAPACITY COIL SUBCOOL MODE
Evaporator Air Quantity Cfm
Temp (F)
18,000
22,500
27,000
Air Entering
Condenser
Evaporator Air Ewb (F)
(Edb)
75
72
67
62
57
75
72
67
62
57
75
72
67
TC
1134 1074 981 894 822 1191 1131 1036 948 878 1230 1170 1075
SHC
398 462 566 668 773 425 503 630 755 859 450 540 690
75
62.5 61.4 59.7 58.3 57.4 63.6 62.5 60.7 59.2 57.9 64.5 63.3 61.5
kW
BF
0.00 0.01 0.02 0.03 0.04 0.00 0.03 0.04 0.04 0.10 0.03 0.05 0.05
TC
1080 1023 935 853 781 1133 1076 985 902 843 1169 1111 1021
358 424 531 636 736 383 462 592 721 826 406 498 650
SHC
85
kW
68.8 67.7 66.2 65.3 64.5 69.9 68.8 67.1 65.8 64.9 70.7 69.5 67.8
BF
0.00 0.01 0.02 0.03 0.04 0.01 0.03 0.04 0.04 0.11 0.03 0.05 0.05
TC
1025 970 887 810 743 1072 1018 933 855 801 1105 1050 965
SHC
318 386 495 603 702 340 420 554 685 785 361 454 610
95
kW
76.1 75.2 74.2 73.6 73.0 77.1 76.0 74.7 73.9 73.2 77.9 76.7 75.2
0.00 0.01 0.02 0.03 0.06 0.01 0.03 0.04 0.04 0.12 0.04 0.05 0.05
BF
965 914 835 762 710 1008 957 877 804 758 1036 986 905
TC
SHC
277 345 458 568 672 295 377 513 648 744 313 409 567
105
84.9 84.4 83.8 83.7 83.4 85.5 84.8 84.1 83.7 83.2 86.0 85.2 84.3
kW
BF
0.00 0.01 0.02 0.03 0.08 0.01 0.03 0.04 0.04 0.14 0.04 0.05 0.05
TC
903 855 780 714 664 940 892 817 748 712 965 917 842
SHC
233 304 418 536 626 248 332 471 608 700 264 361 523
115
kW
95.3 95.0 95.0 95.6 95.6 95.7 95.2 94.9 95.1 94.9 96.0 95.4 94.9
0.00 0.01 0.02 0.03 0.10 0.01 0.03 0.04 0.05 0.16 0.04 0.05 0.05
BF

31,500
62
985
837
59.9
0.06
937
800
66.2
0.06
887
762
74.2
0.06
834
722
83.7
0.06
777
680
94.8
0.07

57
932
932
58.9
0.18
886
886
65.6
0.19
843
843
73.8
0.20
798
798
83.5
0.22
748
748
94.9
0.24

75
1259
474
65.1
0.05
1196
429
71.3
0.05
1129
382
78.4
0.06
1058
332
86.5
0.06
984
282
96.3
0.06

72
1198
577
63.9
0.06
1138
533
70.1
0.06
1074
487
77.3
0.06
1006
440
85.5
0.06
935
391
95.6
0.06

67
1103
748
62.0
0.06
1046
706
68.3
0.06
988
664
75.5
0.06
926
620
84.5
0.06
860
575
95.0
0.07

62
1014
911
60.4
0.08
964
872
66.7
0.08
912
831
74.5
0.09
858
793
83.8
0.10
803
735
94.6
0.12

57
974
974
59.7
0.26
930
930
66.1
0.27
885
885
74.1
0.29
836
836
83.6
0.30
783
783
94.7
0.32

48/50P2,P3,P4,P5090 (90 TON) HIGHCAPACITY COIL SUBCOOL MODE (cont)


Evaporator Air Quantity
Cfm
Temp (F)
Air Entering
36,000
Condenser
Evaporator Air Ewb (F)
(Edb)
75
72
67
62
57
TC
1281 1220 1124 1038 1014
SHC
497 611 803 978 1014
75
kW
65.6 64.4 62.5 60.9 60.4
BF
0.07 0.07 0.08 0.11 0.33
TC
1216 1157 1066 986 967
SHC
450 566 760 935 967
85
kW
71.8 70.5 68.7 67.2 66.8
BF
0.07 0.08 0.08 0.11 0.34
TC
1148 1092 1005 934 919
SHC
402 520 717 888 919
95
kW
78.8 77.7 75.9 74.7 74.5
BF
0.07 0.08 0.08 0.13 0.35
TC
1074 1022 942 881 867
SHC
352 471 672 837 867
105
kW
86.9 85.8 84.7 83.9 83.8
BF
0.07 0.08 0.08 0.14 0.37
TC
998 949 874 824 812
SHC
300 421 624 783 812
115
kW
96.5 95.8 95.0 94.6 94.6
BF
0.07 0.08 0.08 0.16 0.38
LEGEND
48/50P3,P5 units only.
BF Bypass Factor
kW
Compressor Motor Power Input
Edb Entering Dry Bulb
SHC Sensible Heat Cap. (1000 Btuh)
Ewb Entering Wet Bulb
TC
Total Cap. (1000 Btuh) Gross
NOTES:
1. The SHC is based on 80 F edb temperature of air entering evaporator coil. For edb temperatures other than 80 F, adjust SHC by
multiplying the correction factor and the cfm and then adding or
subtracting the value from the SHC.

2. Interpolation is permissible.
3. Correction Factor = 1.10 x (1 BF) x (edb 80).
4. Cooling capacities are gross and do not include deduction for
indoor fan motor heat.
5. SHC values provided are in subcooling mode with the gas bypass
valve closed and reflect the maximum SHC in subcooling mode.
The P Series innovative modulating valve system can reduce SHC
as needed to meet the supply air set point requirement with minimal change in latent capacity. This will provide variable SHC to
meet the space load.

95

Performance data (cont)


COOLING CAPACITIES (cont)
48/50P2,P3,P4,P5090 (90 TON) HIGH-CAPACITY COIL HOT GAS REHEAT MODE
Air Entering Evaporator Ewb (F)
Temp (F)
75 Dry Bulb
Air Ent
62.5 Wet Bulb (50% RH)
Condenser
Air Entering Evaporator Cfm
(Edb)
18,000
22,500
27,000
31,500
36,000
18,000
TC
386
417
437
452
464
410
SHC
61
100
141
184
227
-16
80
kW
65.8
65.2
65.0
64.9
64.9
67.2
BF
0.03
0.04
0.05
0.07
0.08
0.02
TC
396
427
448
463
475
420
SHC
67
107
148
191
235
-9
75
kW
63.3
62.8
62.7
62.8
62.9
64.8
BF
0.03
0.04
0.05
0.06
0.08
0.02
TC
401
431
452
467
478
425
SHC
71
111
152
196
239
-5
70
kW
63.3
63.1
63.1
63.4
63.7
65.0
BF
0.03
0.04
0.05
0.06
0.08
0.02
TC
413
443
463
478
488
436
SHC
81
121
163
207
250
5
60
kW
61.1
61.4
61.9
62.3
62.6
63.3
BF
0.03
0.04
0.05
0.06
0.08
0.02
TC
421
449
469
482
492
442
SHC
89
129
171
215
260
13
50
kW
60.3
61.0
61.6
62.1
62.5
62.8
BF
0.03
0.04
0.05
0.07
0.08
0.02
TC
434
464
484
498
508
456
SHC
100
142
186
231
276
25
40
kW
57.3
58.1
58.7
59.2
59.6
59.7
BF
0.03
0.04
0.05
0.07
0.08
0.02

48/50P2,P3,P4,P5090 (90 TON) HIGH-CAPACITY COIL HOT GAS REHEAT MODE (cont)
Air Entering Evaporator Ewb (F)
Temp (F)
75 Dry Bulb
Air Ent
68 Wet Bulb (70% RH)
Condenser
Air Entering Evaporator Cfm
(Edb)
18,000
22,500
27,000
31,500
36,000
18,000
TC
435
467
489
505
517
458
SHC
-89
-76
-61
-42
-19
-159
80
kW
68.8
68.3
68.3
68.3
68.4
70.5
BF
0.01
0.03
0.05
0.06
0.08
0.00
TC
445
478
500
516
529
468
SHC
-82
-68
-50
-31
-10
-151
75
kW
66.6
66.4
66.5
66.7
66.8
68.5
BF
0.01
0.03
0.05
0.06
0.08
0.00
TC
448
480
501
517
528
471
SHC
-78
-64
-46
-27
-5
-147
70
kW
66.9
67.1
67.3
67.5
67.7
69.1
BF
0.01
0.03
0.05
0.06
0.08
0.00
TC
459
490
511
526
537
481
SHC
-67
-53
-35
-14
8
-137
60
kW
65.6
65.9
66.3
66.6
66.8
67.9
BF
0.01
0.03
0.05
0.06
0.08
0.00
TC
464
494
514
528
539
485
SHC
-60
-44
-25
-4
19
-129
50
kW
65.3
65.8
66.3
66.7
67.0
67.7
BF
0.01
0.03
0.05
0.06
0.08
0.00
TC
479
510
531
546
557
500
SHC
-47
-29
-8
14
38
-114
40
kW
62.2
62.8
63.3
63.8
64.1
64.6
BF
0.01
0.03
0.05
0.06
0.08
0.00

LEGEND
BF Bypass Factor
RH
Relative Humidity
Edb Entering Dry Bulb
SHC Sensible Heat Cap. (1000 Btuh)
Ewb Entering Wet Bulb
TC
Total Cap. (1000 Btuh) Gross
kW Compressor Motor Power
Input
NOTES:
1. The SHC is based on 75 F edb temperature of air entering evaporator coil. For edb temperatures other than 75 F, adjust SHC by
multiplying the correction factor and the cfm and then adding or
subtracting the value from the SHC.
2. Interpolation is permissible.
3. Correction Factor = 1.10 x (1 BF) x (edb 75).
4. Cooling capacities are gross and do not include deduction for
indoor fan motor heat.
5. Capacity table includes impact of outdoor fan staging at temperatures below 75 F.

96

75 Dry Bulb
65.3 Wet Bulb (60% RH)
22,500
442
11
66.6
0.04
452
18
64.4
0.04
456
22
64.9
0.04
467
33
63.7
0.04
472
41
63.4
0.04
487
55
60.4
0.04

27,000
463
39
66.5
0.05
474
47
64.5
0.05
477
52
65.2
0.05
487
63
64.1
0.05
491
71
64.0
0.05
507
87
61.0
0.05

31,500
478
68
66.5
0.06
490
78
64.7
0.06
492
83
65.5
0.06
502
94
64.4
0.06
505
104
64.4
0.06
522
121
61.5
0.06

36,000
490
102
66.5
0.08
502
111
64.9
0.08
503
115
65.7
0.08
513
128
64.7
0.08
516
138
64.8
0.08
533
155
61.8
0.08

31,500
530
-141
70.2
0.06
542
-132
68.5
0.06
541
-128
69.5
0.06
549
-115
68.6
0.06
550
-104
68.9
0.06
568
-85
65.9
0.06

36,000
542
-131
70.3
0.07
554
-123
68.6
0.07
552
-118
69.6
0.07
560
-105
68.8
0.08
562
-93
69.1
0.08
580
-73
66.2
0.08

75 Dry Bulb
70.5 Wet Bulb (80% RH)
22,500
491
-156
70.1
0.01
502
-147
68.3
0.01
503
-143
69.2
0.01
512
-132
68.1
0.01
515
-123
68.1
0.01
532
-107
65.1
0.01

27,000
513
-150
70.1
0.04
525
-141
68.4
0.04
525
-137
69.3
0.04
534
-125
68.4
0.04
536
-114
68.5
0.04
553
-97
65.5
0.04

6. SHC values provided reflect maximum reheat values with 100%


gas bypass. Negative SHC value indicates that the air entering
the coil is being heated at 100% gas bypass. The P Series innovative modulating valve system will reduce the gas bypass as
required to meet the supply air setpoint with minimal change in
latent capacity. The space will NOT be overheated and the unit
will provide variable SHC to meet the space load.

COOLING CAPACITIES (cont)


48/50P2,P3,P4,P5100 (100 TON) STANDARD CAPACITY COIL STANDARD MODE
Evaporator Air Quantity Cfm
Temp (F)
20,000
25,000
Air Entering
Condenser
Evaporator Air Ewb (F)
(Edb)
75
72
67
62
57
75
72
67
62
57
TC
1198
1147
1057
970
883
1251
1194
1104
1017
944
SHC
489
549
663
768
854
509
593
727
856
928
75
kW
68.6
67.4
65.6
64.1
62.7
69.9
68.5
66.6
65.0
63.7
BF
0.00
0.00
0.14
0.11
0.13
0.00
0.23
0.14
0.12
0.22
TC
1161
1111
1023
938
855
1209
1155
1068
982
923
SHC
475
536
648
752
833
490
579
711
840
892
85
kW
75.7
74.6
72.9
71.5
70.2
77.0
75.7
73.9
72.4
71.2
BF
0.00
0.10
0.14
0.10
0.14
0.00
0.20
0.14
0.12
0.27
TC
1121
1071
985
902
825
1164
1113
1027
942
893
SHC
457
522
632
735
811
480
564
695
821
870
95
kW
84.1
83.0
81.4
80.0
79.3
85.2
84.1
82.4
80.8
79.7
BF
0.00
0.08
0.13
0.10
0.15
0.14
0.18
0.13
0.12
0.28
TC
1077
1026
942
861
796
1113
1064
981
899
849
SHC
436
506
613
716
775
464
547
676
800
848
105
kW
93.7
92.7
91.4
90.5
89.8
94.7
93.7
92.1
91.3
90.9
BF
0.00
0.07
0.12
0.10
0.20
0.10
0.17
0.13
0.12
0.27
817
759
851
812
TC
1025
976
895
1057
1010
930
SHC
747
812
417
487
593
695
447
528
656
778
115
kW
104.6 103.9 103.4 103.4 103.1 105.4 104.6 103.9 103.9 103.8
BF
0.00
0.18
0.11
0.09
0.21
0.08
0.15
0.12
0.12
0.30

30,000
75
1285
535
70.8
0.12
1238
521
77.8
0.10
1191
506
86.0
0.28
1139
490
95.4
0.23
1080
471
106.1
0.20

72
1228
632
69.3
0.19
1186
617
76.5
0.18
1141
602
84.8
0.17
1090
585
94.3
0.16
1034
565
105.3
0.16

67
1138
786
67.4
0.15
1099
771
74.6
0.15
1056
754
83.1
0.14
1007
735
92.7
0.14
954
715
104.3
0.14

62
1050
935
65.7
0.14
1012
917
73.0
0.14
970
896
81.5
0.14
924
872
91.9
0.15
875
841
104.1
0.17

57
991
991
64.7
0.28
975
947
72.2
0.35
933
933
80.8
0.33
897
897
91.4
0.36
858
858
104.0
0.39

48/50P2,P3,P4,P5100 (100 TON) STANDARD CAPACITY COIL STANDARD MODE (cont)


Evaporator Air Quantity Cfm
Temp (F)
35,000
40,000
Air Entering
Condenser
Evaporator Air Ewb (F)
(Edb)
75
72
67
62
57
75
72
67
62
57
TC
1310
1252
1162
1073
1038
1329
1273
1181
1092
1074
SHC
561
669
843
1005
1038
584
705
898
1059
1074
75
kW
71.4
70.0
68.0
66.2
65.5
71.9
70.5
68.4
66.6
66.2
BF
0.27
0.19
0.16
0.17
0.36
0.24
0.19
0.17
0.21
0.42
1260
1206
1121
1034
1007
1278
1224
1139
1054
1044
TC
SHC
545
654
828
980
1007
568
688
882
1032
1044
85
kW
78.4
77.1
75.2
73.5
72.9
78.9
77.5
75.6
73.9
73.6
BF
0.25
0.18
0.16
0.18
0.38
0.23
0.18
0.17
0.22
0.44
TC
1212
1160
1077
992
973
1228
1177
1093
1014
1006
SHC
530
638
810
951
973
553
671
865
992
1006
95
kW
86.6
85.3
83.6
81.9
81.5
87.0
85.8
84.0
82.3
82.2
BF
0.23
0.17
0.16
0.19
0.40
0.22
0.18
0.17
0.25
0.46
1158
1108
1026
947
937
1173
1123
1041
970
967
TC
SHC
513
620
791
926
937
536
653
845
960
967
105
kW
95.9
94.8
93.2
92.2
91.7
96.4
95.3
93.6
92.5
92.4
BF
0.21
0.17
0.15
0.20
0.43
0.21
0.18
0.17
0.27
0.48
1098
1110
TC
1050
972
901
894
1063
985
923
922
SHC
495
517
600
770
882
894
633
824
923
922
115
kW
106.6 105.7 104.7 104.0 104.2 107.0 106.1 104.9 104.4 104.5
BF
0.19
0.16
0.15
0.24
0.45
0.20
0.17
0.17
0.29
0.51
LEGEND
3. SHC is based on 80 F edb temperature of air entering evaporator
coil.
48/50P3,P5 units only.
Below 80 F edb, subtract (corr factor x cfm) from SHC.
Above 80 F edb, add (corr factor x cfm) to SHC.
BF Bypass Factor
kW
Compressor Motor Power Input
Edb Entering Dry Bulb
SHC Sensible Heat Cap. (1000 Btuh)
Ewb Entering Wet Bulb
TC
Total Cap. (1000 Btuh) Gross
ENTERING AIR DRY-BULB TEMP (F)
79
78
77
76
75
under 75
NOTES:
BF
81
82
83
84
85
over 85
1. Direct interpolation is permissible. Do not extrapolate.
2. The following formulas may be used:
Correction Factor
sensible capacity (Btuh)
.05
1.04
2.09
3.14
4.18
5.22
tldb = tedb
Use formula
.10
0.99
1.98
2.97
3.96
4.95 shown below
1.10 x cfm
.20
0.88
1.76
2.64
3.52
4.40
Wet-bulb temperature corresponding to enthalpy of air
tlwb =
leaving evaporator coil (hlwb).
Interpolation is permissible.
Correction Factor = 1.10 x (1 BF) x (edb 80).
total capacity (Btuh)
hlwb = hewb
4. Cooling capacities are gross and do not include deduction for indoor
4.5 x cfm
fan motor heat.
Where: hewb = Enthalpy of air entering evaporator coil.

97

Performance data (cont)


COOLING CAPACITIES (cont)
48/50P2,P3,P4,P5100 (100 TON) STANDARD CAPACITY COIL SUBCOOL MODE
Evaporator Air Quantity Cfm
Temp (F)
20,000
25,000
Air Entering
Condenser
Evaporator Air Ewb (F)
(Edb)
75
72
67
62
57
75
72
67
62
57
TC
1146
1084
987
897
815
1203
1165
1042
949
873
SHC
418
481
581
680
773
450
548
645
764
850
75
67.9
66.6
64.7
63.1
61.7
69.1
68.7
65.9
64.1
62.5
kW
BF
0.00
0.07
0.10
0.11
0.12
0.05
0.11
0.13
0.13
0.21
TC
1064
1005
946
856
779
1111
1053
991
913
836
351
414
551
648
735
373
450
607
739
814
SHC
85
kW
74.1
72.8
71.6
70.1
68.7
75.2
73.9
72.5
71.1
69.5
BF
0.00
0.07
0.10
0.11
0.15
0.05
0.11
0.13
0.13
0.22
TC
1004
941
894
813
762
1042
995
906
857
814
SHC
306
365
511
614
719
321
408
535
695
793
95
kW
81.6
80.2
79.5
78.3
77.8
82.6
81.5
79.6
78.9
78.4
0.00
0.07
0.10
0.11
0.16
0.06
0.11
0.13
0.14
0.23
BF
TC
931
898
843
766
724
976
926
846
807
771
SHC
251
337
474
579
683
274
356
490
658
753
105
90.0
89.4
88.9
87.8
87.5
91.1
90.0
88.7
88.3
88.0
kW
BF
0.01
0.07
0.10
0.11
0.18
0.06
0.11
0.13
0.14
0.25
TC
867
835
792
715
683
905
859
797
762
726
SHC
206
292
439
543
644
225
309
460
628
710
115
kW
100.2
99.7
99.9
98.8
98.7
100.9 100.1
99.5
99.5
99.0
BF
0.01
0.07
0.10
0.11
0.19
0.06
0.11
0.13
0.14
0.26

48/50P2,P3,P4,P5100 (100 TON) STANDARD CAPACITY COIL SUBCOOL MODE (cont)


Evaporator Air Quantity Cfm
Temp (F)
35,000
40,000
Air Entering
Condenser
Evaporator Air Ewb (F)
(Edb)
75
72
67
62
57
75
72
67
62
TC
1273
1210
1133
1020
973
1296
1233
1157
1036
SHC
499
597
781
915
973
522
630
834
968
75
kW
70.8
69.4
68.1
65.5
64.6
71.4
70.0
68.7
65.9
BF
0.13
0.16
0.17
0.19
0.35
0.16
0.18
0.19
0.22
TC
1164
1107
1024
969
917
1186
1130
1043
967
SHC
408
510
685
875
917
429
543
734
906
85
kW
76.6
75.3
73.4
72.2
71.0
77.2
75.8
74.0
72.3
BF
0.14
0.16
0.17
0.19
0.36
0.16
0.18
0.19
0.23
TC
1096
1044
961
914
886
1114
1059
979
935
SHC
359
465
638
829
886
377
490
687
875
95
kW
84.0
82.8
80.9
79.9
79.5
84.5
83.2
81.4
80.3
BF
0.14
0.16
0.17
0.20
0.38
0.16
0.18
0.19
0.25
TC
1021
974
900
860
838
1037
990
918
886
SHC
306
415
595
782
838
322
442
644
828
105
kW
92.4
91.2
89.7
89.1
88.9
92.8
91.7
90.1
89.6
BF
0.14
0.16
0.17
0.22
0.39
0.16
0.18
0.19
0.27
TC
944
901
833
806
787
824
955
913
841
SHC
252
363
547
729
787
765
265
388
586
115
kW
101.8 100.9
99.9
99.8
99.7
100.0 102.1 101.2 100.0
BF
0.14
0.16
0.17
0.24
0.41
0.27
0.16
0.18
0.20
LEGEND
48/50P3,P5 units only.
BF Bypass Factor
kW
Compressor Motor Power Input
Edb Entering Dry Bulb
SHC Sensible Heat Cap. (1000 Btuh)
Ewb Entering Wet Bulb
TC
Total Cap. (1000 Btuh) Gross
NOTES:
1. The SHC is based on 80 F edb temperature of air entering evaporator coil. For edb temperatures other than 80 F, adjust SHC by
multiplying the correction factor and the cfm and then adding or
subtracting the value from the SHC.

98

30,000
75
1261
494
70.6
0.10
1141
390
76.0
0.10
1073
340
83.4
0.10
1003
291
91.8
0.11
927
238
101.4
0.11

72
1167
547
68.5
0.14
1089
484
74.8
0.14
1024
437
82.3
0.14
955
387
90.7
0.14
882
335
100.6
0.14

67
1071
693
66.5
0.15
1003
638
73.0
0.15
945
596
80.5
0.15
866
533
89.0
0.15
823
508
99.7
0.15

62
986
841
64.8
0.16
939
805
71.5
0.16
889
767
79.5
0.17
836
727
88.8
0.17
779
686
99.5
0.18

57
932
932
63.9
0.27
892
892
70.8
0.29
850
850
79.0
0.30
805
805
88.5
0.32
756
756
99.4
0.34

57
998
998
65.0
0.41
964
964
72.1
0.42
876
876
79.0
0.43
825
825
88.2
0.45
813
813
99.9
0.46

2. Interpolation is permissible.
3. Correction Factor = 1.10 x (1 BF) x (edb 80).
4. Cooling capacities are gross and do not include deduction for
indoor fan motor heat.
5. SHC values provided are in subcooling mode with the gas bypass
valve closed and reflect the maximum SHC in subcooling mode.
The P Series innovative modulating valve system can reduce SHC
as needed to meet the supply air set point requirement with minimal change in latent capacity. This will provide variable SHC to
meet the space load.

COOLING CAPACITIES (cont)


48/50P2,P3,P4,P5100 (100 TON) STANDARD CAPACITY COIL HOT GAS REHEAT MODE
Air Entering Evaporator Ewb (F)
Temp (F)
75 Dry Bulb
Air Ent
62.5 Wet Bulb (50% RH)
Condenser
Air Entering Evaporator Cfm
(Edb)
20,000
25,000
30,000
35,000
40,000
20,000
TC
348
374
393
406
417
370
SHC
27
62
99
136
173
-51
80
kW
71.6
71.3
71.1
71.1
71.1
73.3
BF
0.10
0.13
0.15
0.17
0.19
0.09
TC
366
394
413
427
438
390
SHC
42
78
115
153
190
-35
75
kW
68.5
68.2
68.2
68.2
68.2
70.2
BF
0.10
0.13
0.15
0.17
0.19
0.09
TC
372
399
418
432
442
395
SHC
47
82
120
157
195
-30
70
kW
68.5
68.4
68.4
68.6
68.8
70.3
BF
0.10
0.13
0.15
0.17
0.19
0.09
TC
385
412
430
444
457
407
SHC
57
94
132
170
200
-19
60
kW
66.3
66.6
67.1
67.5
67.1
68.6
BF
0.10
0.13
0.15
0.18
0.20
0.09
TC
434
460
478
491
501
458
SHC
155
197
239
279
319
84
50
kW
50.1
50.7
51.3
51.7
52.0
51.6
BF
0.11
0.14
0.17
0.19
0.21
0.11
TC
449
478
495
509
519
473
SHC
166
199
251
292
332
97
40
kW
47.0
46.9
48.3
48.7
49.1
48.6
BF
0.11
0.14
0.17
0.19
0.21
0.11

48/50P2,P3,P4,P5100 (100 TON) STANDARD CAPACITY COIL HOT GAS REHEAT MODE (cont)
Air Entering Evaporator Ewb (F)
Temp (F)
75 Dry Bulb
Air Ent
68 Wet Bulb (70% RH)
Condenser
Air Entering Evaporator Cfm
(Edb)
20,000
25,000
30,000
35,000
40,000
20,000
TC
393
422
442
456
479
415
SHC
-127
-116
-104
-88
-56
-198
80
kW
75.0
74.6
74.6
74.7
73.8
77.0
BF
0.07
0.11
0.14
0.16
0.18
0.00
TC
413
443
464
479
491
436
SHC
-109
-96
-81
-64
-46
-178
75
kW
72.0
71.8
72.1
72.2
72.3
74.1
BF
0.07
0.11
0.14
0.16
0.18
0.00
TC
417
446
466
481
492
439
SHC
-103
-91
-75
-58
-40
-172
70
kW
72.4
72.5
72.8
73.1
73.2
74.8
BF
0.07
0.11
0.14
0.16
0.18
0.00
TC
429
457
477
495
507
450
SHC
-91
-76
-58
-53
-37
-158
60
kW
71.2
71.6
72.0
70.9
71.0
73.7
BF
0.07
0.11
0.14
0.16
0.19
0.00
TC
481
508
527
540
551
504
SHC
17
35
55
75
95
-47
50
kW
53.1
53.7
54.2
54.6
54.8
54.6
BF
0.08
0.13
0.16
0.19
0.21
0.03
TC
496
527
544
559
570
519
SHC
30
37
69
90
110
-34
40
kW
50.1
49.9
51.3
51.7
51.9
51.6
BF
0.08
0.12
0.16
0.19
0.21
0.03

LEGEND
BF Bypass Factor
RH
Relative Humidity
Edb Entering Dry Bulb
SHC Sensible Heat Cap. (1000 Btuh)
Ewb Entering Wet Bulb
TC
Total Cap. (1000 Btuh) Gross
kW Compressor Motor Power
Input
NOTES:
1. The SHC is based on 75 F edb temperature of air entering evaporator coil. For edb temperatures other than 75 F, adjust SHC by
multiplying the correction factor and the cfm and then adding or
subtracting the value from the SHC.
2. Interpolation is permissible.

75 Dry Bulb
65.3 Wet Bulb (60% RH)
25,000
398
-28
72.8
0.12
418
-11
69.9
0.12
423
-7
70.2
0.12
435
6
69.0
0.12
484
115
52.2
0.14
502
117
48.4
0.14

30,000
417
-3
72.7
0.15
438
15
69.9
0.15
442
20
70.5
0.15
454
34
69.5
0.15
503
145
52.7
0.17
520
159
49.8
0.17

35,000
431
21
72.8
0.17
453
42
70.1
0.17
456
47
70.8
0.17
468
63
69.9
0.17
516
175
53.2
0.19
534
189
50.2
0.19

40,000
453
60
71.9
0.19
465
70
70.2
0.19
467
75
71.0
0.19
482
79
69.0
0.20
526
204
53.4
0.21
545
219
50.5
0.21

35,000
492
-172
75.9
0.14
503
-161
74.4
0.14
504
-155
75.3
0.14
518
-151
72.8
0.12
564
-17
56.0
0.16
583
-1
53.0
0.16

40,000
504
-164
75.9
0.16
516
-152
74.4
0.16
515
-144
75.4
0.16
530
-143
72.9
0.15
574
-5
56.2
0.19
594
10
53.2
0.19

75 Dry Bulb
70.5 Wet Bulb (80% RH)
25,000
445
-195
76.5
0.05
466
-174
74.1
0.05
469
-169
74.9
0.05
479
-152
74.0
0.06
530
-37
55.2
0.08
550
-37
51.3
0.07

30,000
477
-179
75.7
0.10
488
-169
74.2
0.10
489
-162
75.1
0.10
503
-158
72.6
0.08
550
-28
55.6
0.13
568
-13
52.6
0.13

3. Correction Factor = 1.10 x (1 BF) x (edb 75).


4. Cooling capacities are gross and do not include deduction for
indoor fan motor heat.
5. Capacity table includes impact of outdoor fan staging at temperatures below 75 F.
6. SHC values provided reflect maximum reheat values with 100%
gas bypass. Negative SHC value indicates that the air entering
the coil is being heated at 100% gas bypass. The P Series innovative modulating valve system will reduce the gas bypass as
required to meet the supply air setpoint with minimal change in
latent capacity. The space will NOT be overheated and the unit
will provide variable SHC to meet the space load.

99

Performance data (cont)


COOLING CAPACITIES (cont)
48/50P2,P3,P4,P5100 (100 TON) HIGH-CAPACITY COIL STANDARD MODE
Evaporator Air Quantity Cfm
Temp (F)
20,000
25,000
Air Entering
Condenser
Evaporator Air Ewb (F)
(Edb)
75
72
67
62
57
75
72
67
62
57
TC
1269
1208
1114
1026
941
1332
1267
1171
1081
1010
SHC
524
591
707
820
910
552
640
782
920
1002
75
kW
71.2
69.7
67.3
65.4
63.7
72.9
71.1
68.7
66.6
65.0
BF
0.00
0.05
0.05
0.03
0.06
0.10
0.08
0.05
0.04
0.15
TC
1231
1172
1084
998
916
1285
1227
1136
1048
987
SHC
505
577
694
805
891
537
626
767
904
977
85
kW
78.3
76.7
74.6
72.8
71.1
79.7
78.3
75.9
74.1
72.5
BF
0.00
0.11
0.05
0.03
0.07
0.07
0.07
0.05
0.04
0.17
TC
1189
1136
1049
963
887
1241
1183
1097
1010
955
SHC
488
563
678
788
871
522
609
751
885
955
95
kW
86.5
85.1
83.2
81.5
80.1
88.0
86.5
84.5
82.7
81.3
BF
0.00
0.10
0.04
0.03
0.08
0.06
0.07
0.05
0.04
0.18
TC
1147
1090
1007
923
853
1193
1139
1051
965
921
SHC
473
545
659
768
849
506
592
731
863
921
105
kW
96.1
94.7
93.3
92.4
90.6
97.6
96.3
94.6
93.4
92.2
BF
0.00
0.07
0.04
0.03
0.09
0.13
0.07
0.04
0.04
0.21
877
817
915
883
TC
1095
1043
959
1137
1085
999
SHC
816
883
455
526
638
746
487
572
710
839
115
kW
107.2 106.4 105.6 105.4 104.0 108.8 107.9 106.7 106.4 104.6
BF
0.08
0.07
0.04
0.03
0.12
0.10
0.06
0.04
0.05
0.24

30,000
75
1373
585
73.9
0.14
1324
568
80.8
0.12
1275
552
89.0
0.10
1224
535
98.6
0.09
1166
516
109.9
0.08

72
1308
685
72.2
0.08
1265
670
79.2
0.07
1221
653
87.6
0.07
1170
635
97.3
0.07
1113
614
108.8
0.06

67
1210
852
69.7
0.06
1173
836
76.9
0.05
1131
819
85.5
0.05
1082
800
95.5
0.05
1027
778
107.6
0.05

62
1118
1010
67.5
0.06
1083
993
74.9
0.06
1041
971
83.4
0.06
995
945
94.0
0.07
945
912
106.5
0.09

57
1069
1069
66.4
0.24
1043
1043
73.8
0.25
1012
1012
82.5
0.28
975
975
93.0
0.30
933
933
105.5
0.33

48/50P2,P3,P4,P5100 (100 TON) HIGH-CAPACITY COIL STANDARD MODE (cont)


Evaporator Air Quantity Cfm
Temp (F)
35,000
40,000
Air Entering
Condenser
Evaporator Air Ewb (F)
(Edb)
75
72
67
62
57
75
72
67
62
57
TC
1402
1337
1239
1144
1118
1426
1360
1260
1170
1159
SHC
613
729
919
1086
1118
640
769
984
1149
1159
75
kW
74.7
73.0
70.4
68.2
67.6
75.3
73.6
71.0
68.8
68.6
BF
0.11
0.07
0.06
0.09
0.31
0.10
0.08
0.07
0.13
0.38
TC
1351
1292
1199
1107
1090
1373
1313
1219
1135
1128
SHC
596
712
903
1064
1090
623
753
967
1121
1128
85
kW
81.6
80.0
77.6
75.5
74.9
82.2
80.6
78.2
76.1
75.9
BF
0.10
0.08
0.06
0.09
0.33
0.10
0.08
0.07
0.15
0.40
TC
1302
1246
1155
1069
1057
1322
1264
1173
1097
1093
SHC
580
695
886
1038
1057
606
736
949
1083
1093
95
kW
89.8
88.3
86.2
84.1
83.7
90.4
88.9
86.8
84.7
84.6
BF
0.09
0.07
0.06
0.11
0.35
0.09
0.08
0.07
0.18
0.41
TC
1249
1192
1104
1026
1018
1266
1209
1120
1054
1052
SHC
562
677
865
1004
1018
588
717
928
1048
1052
105
kW
99.4
98.0
96.2
94.4
94.0
100.0
98.6
96.8
94.6
94.7
BF
0.09
0.07
0.06
0.13
0.38
0.09
0.08
0.07
0.20
0.44
1187
1204
TC
1133
1046
976
973
1149
1061
1009
1006
SHC
542
656
842
971
973
568
696
904
999
1006
115
kW
110.6 109.5 108.3 105.9 106.2 111.5 110.2 108.6 106.8 106.9
BF
0.08
0.07
0.06
0.15
0.40
0.09
0.07
0.07
0.24
0.46
LEGEND
3. SHC is based on 80 F edb temperature of air entering evaporator
coil.
48/50P3,P5 units only.
Below 80 F edb, subtract (corr factor x cfm) from SHC.
Above 80 F edb, add (corr factor x cfm) to SHC.
BF Bypass Factor
kW
Compressor Motor Power Input
Edb Entering Dry Bulb
SHC Sensible Heat Cap. (1000 Btuh)
Ewb Entering Wet Bulb
TC
Total Cap. (1000 Btuh) Gross
ENTERING AIR DRY-BULB TEMP (F)
79
78
77
76
75
under 75
NOTES:
BF
1. Direct interpolation is permissible. Do not extrapolate.
81
82
83
84
85
over 85
2. The following formulas may be used:
Correction Factor
sensible capacity (Btuh)
.05
1.04
2.09
3.14
4.18
5.22
tldb = tedb
Use formula
.10
0.99
1.98
2.97
3.96
4.95 shown below
1.10 x cfm
.20
0.88
1.76
2.64
3.52
4.40
Wet-bulb temperature corresponding to enthalpy of air
tlwb =
leaving evaporator coil (hlwb).
Interpolation is permissible.
Correction Factor = 1.10 x (1 BF) x (edb 80).
total capacity (Btuh)
hlwb = hewb
4. Cooling capacities are gross and do not include deduction for indoor
4.5 x cfm
fan motor heat.
Where: h
= Enthalpy of air entering evaporator coil.
ewb

100

COOLING CAPACITIES (cont)


48/50P2,P3,P4,P5100 (100 TON) HIGH-CAPACITY COIL SUBCOOL MODE
Evaporator Air Quantity Cfm
Temp (F)
20,000
25,000
Air Entering
Condenser
Evaporator Air Ewb (F)
(Edb)
75
72
67
62
57
75
72
67
62
57
TC
1210
1148
1077
994
900
1255
1205
1119
1042
951
SHC
417
489
633
756
848
433
531
687
843
924
75
69.7
68.3
66.8
65.4
64.1
70.8
69.6
67.7
66.2
64.1
kW
BF
0.00
0.01
0.03
0.03
0.06
0.01
0.04
0.04
0.05
0.13
TC
1152
1116
1016
942
863
1204
1140
1077
993
933
374
471
584
714
811
398
482
658
806
907
SHC
85
kW
76.4
75.5
73.3
72.6
71.7
77.7
76.2
74.8
73.2
72.4
BF
0.00
0.01
0.03
0.03
0.08
0.01
0.04
0.04
0.05
0.14
TC
1091
1035
965
876
825
1139
1083
1017
926
890
SHC
329
405
546
659
774
350
441
614
752
866
95
kW
84.2
82.9
81.9
80.7
80.9
85.4
84.1
82.8
81.3
81.3
0.00
0.01
0.03
0.03
0.09
0.01
0.04
0.04
0.05
0.15
BF
1027
1000
909
824
758
1068
1013
957
888
844
TC
SHC
283
387
505
621
709
300
390
571
728
823
105
93.4
93.2
92.0
91.3
90.3
94.3
93.2
92.7
92.2
91.8
kW
BF
0.00
0.01
0.03
0.03
0.11
0.02
0.04
0.04
0.05
0.17
TC
960
935
849
789
715
987
929
892
811
794
SHC
237
342
476
602
669
242
327
541
668
775
115
kW
104.3 104.5 103.8 104.7 102.8 104.7 103.8 104.2 103.5 104.2
0.01
0.02
0.03
0.03
0.13
0.02
0.04
0.05
0.06
0.19
BF

48/50P2,P3,P4,P5100 (100 TON) HIGH-CAPACITY COIL SUBCOOL MODE (cont)


Evaporator Air Quantity Cfm
Temp (F)
35,000
40,000
Air Entering
Condenser
Evaporator Air Ewb (F)
(Edb)
75
72
67
62
57
75
72
67
TC
1334
1272
1173
1099
1046
1356
1293
1220
SHC
494
609
800
996
1046
517
646
885
75
kW
72.9
71.4
69.1
67.3
66.2
73.6
72.0
69.8
BF
0.06
0.07
0.07
0.09
0.28
0.08
0.08
0.09
TC
1302
1263
1111
1056
1018
1323
1262
1129
SHC
487
621
753
962
1018
510
636
809
85
kW
79.7
79.1
75.7
74.4
73.5
80.3
78.9
76.2
BF
0.06
0.07
0.07
0.10
0.29
0.08
0.09
0.09
TC
1194
1138
1049
991
978
1208
1147
1067
SHC
391
510
708
904
978
407
535
765
95
kW
87.0
85.6
83.5
82.3
82.3
87.5
85.9
83.9
BF
0.06
0.07
0.07
0.11
0.30
0.08
0.09
0.09
TC
1117
1058
976
935
925
1133
1080
995
SHC
337
451
654
850
925
355
490
711
105
kW
95.6
94.2
92.7
92.2
92.4
96.1
94.7
93.0
BF
0.07
0.07
0.07
0.13
0.32
0.08
0.09
0.09
TC
1037
980
902
889
869
1050
994
911
SHC
281
396
602
808
869
298
428
649
115
kW
105.8 104.7 103.6 104.2 104.1 106.2 105.0 103.7
BF
0.07
0.07
0.08
0.15
0.34
0.08
0.09
0.09
LEGEND
48/50P3,P5 units only.
BF Bypass Factor
kW
Compressor Motor Power Input
Edb Entering Dry Bulb
SHC Sensible Heat Cap. (1000 Btuh)
Ewb Entering Wet Bulb
TC
Total Cap. (1000 Btuh) Gross
NOTES:
1. The SHC is based on 80 F edb temperature of air entering evaporator coil. For edb temperatures other than 80 F, adjust SHC by
multiplying the correction factor and the cfm and then adding or
subtracting the value from the SHC.

62
1135
1072
68.2
0.13
1078
1010
74.9
0.14
1014
949
82.6
0.15
972
915
92.9
0.18
896
837
103.8
0.19

30,000
75
1306
470
72.1
0.04
1274
461
79.0
0.04
1171
370
86.3
0.04
1097
318
95.0
0.05
1010
255
105.2
0.05

72
1243
571
70.6
0.05
1213
560
77.6
0.06
1110
471
84.8
0.05
1041
422
93.8
0.05
971
374
104.6
0.05

67
1145
738
68.4
0.06
1136
745
76.2
0.06
1026
650
82.9
0.06
924
567
91.7
0.06
893
556
103.7
0.06

62
1080
929
67.0
0.07
1029
889
73.8
0.07
975
848
82.3
0.07
919
805
92.4
0.08
844
736
103.3
0.10

57
1025
1025
66.0
0.19
981
981
73.1
0.21
935
935
81.8
0.22
885
885
92.2
0.24
810
810
103.1
0.26

57
1114
1114
67.7
0.35
1051
1051
74.2
0.36
1012
1012
82.8
0.37
957
957
92.7
0.38
898
898
104.1
0.40

2. Interpolation is permissible.
3. Correction Factor = 1.10 x (1 BF) x (edb 80).
4. Cooling capacities are gross and do not include deduction for
indoor fan motor heat.
5. SHC values provided are in subcooling mode with the gas bypass
valve closed and reflect the maximum SHC in subcooling mode.
The P Series innovative modulating valve system can reduce SHC
as needed to meet the supply air set point requirement with minimal change in latent capacity. This will provide variable SHC to
meet the space load.

101

Performance data (cont)


COOLING CAPACITIES (cont)
48/50P2,P3,P4,P5100 (100 TON) HIGH-CAPACITY COIL HOT GAS REHEAT MODE
Air Entering Evaporator Ewb (F)
Temp (F)
75 Dry Bulb
Air Ent
62.5 Wet Bulb (50% RH)
Condenser
Air Entering Evaporator Cfm
(Edb)
20,000
25,000
30,000
35,000
40,000
20,000
TC
384
412
432
446
457
408
SHC
36
76
120
166
210
-49
80
kW
73.1
72.5
72.4
72.3
72.3
74.9
BF
0.03
0.05
0.06
0.08
0.09
0.03
TC
394
423
443
457
469
418
SHC
43
84
128
173
219
-42
75
kW
70.6
70.2
70.2
70.4
70.5
72.5
BF
0.03
0.05
0.06
0.07
0.09
0.03
TC
399
427
446
460
471
422
SHC
46
87
131
177
222
-39
70
kW
70.7
70.5
70.7
71.0
71.2
72.8
BF
0.03
0.05
0.06
0.07
0.09
0.03
TC
412
439
458
471
481
434
SHC
57
97
142
188
234
-29
60
kW
68.6
69.0
69.5
70.0
70.2
71.2
BF
0.03
0.05
0.06
0.07
0.09
0.03
TC
419
445
463
475
485
440
SHC
63
105
149
197
244
-22
50
kW
68.0
68.7
69.4
69.9
70.2
70.8
BF
0.03
0.05
0.06
0.07
0.09
0.03
TC
433
460
478
491
501
455
SHC
75
118
164
213
261
-9
40
kW
64.9
65.8
66.5
67.1
67.4
67.8
BF
0.03
0.05
0.06
0.07
0.09
0.03

48/50P2,P3,P4,P5100 (100 TON) HIGH-CAPACITY COIL HOT GAS REHEAT MODE (cont)
Air Entering Evaporator Ewb (F)
Temp (F)
75 Dry Bulb
Air Ent
68 Wet Bulb (70% RH)
Condenser
Air Entering Evaporator Cfm
(Edb)
20,000
25,000
30,000
35,000
40,000
20,000
TC
432
462
483
498
509
455
SHC
-132
-120
-105
-86
-61
-211
80
kW
76.9
76.4
76.5
76.7
76.7
79.1
BF
0.01
0.04
0.06
0.07
0.09
0.00
TC
442
473
494
509
521
465
SHC
-126
-111
-93
-73
-51
-202
75
kW
74.7
74.6
74.8
75.0
75.1
77.1
BF
0.01
0.04
0.06
0.07
0.09
0.00
TC
446
475
495
509
520
467
SHC
-122
-108
-93
-71
-49
-199
70
kW
75.3
75.4
75.6
76.0
76.1
77.8
BF
0.01
0.04
0.06
0.07
0.09
0.00
TC
456
485
504
518
528
477
SHC
-110
-98
-80
-58
-35
-189
60
kW
74.0
74.3
74.7
75.1
75.3
76.7
BF
0.02
0.04
0.06
0.07
0.09
0.00
TC
461
488
507
520
530
481
SHC
-104
-89
-69
-47
-23
-181
50
kW
73.7
74.3
74.9
75.3
75.6
76.6
BF
0.02
0.04
0.06
0.07
0.09
0.00
TC
476
504
524
537
548
497
SHC
-90
-72
-51
-27
-2
-165
40
kW
70.7
71.4
72.0
72.5
72.8
73.6
BF
0.02
0.04
0.06
0.07
0.09
0.00

LEGEND
BF Bypass Factor
RH
Relative Humidity
Edb Entering Dry Bulb
SHC Sensible Heat Cap. (1000 Btuh)
Ewb Entering Wet Bulb
TC
Total Cap. (1000 Btuh) Gross
kW Compressor Motor Power
Input
NOTES:
1. The SHC is based on 75 F edb temperature of air entering evaporator coil. For edb temperatures other than 75 F, adjust SHC by
multiplying the correction factor and the cfm and then adding or
subtracting the value from the SHC.
2. Interpolation is permissible.
3. Correction Factor = 1.10 x (1 BF) x (edb 75).
4. Cooling capacities are gross and do not include deduction for
indoor fan motor heat.
5. Capacity table includes impact of outdoor fan staging at temperatures below 75 F.

102

75 Dry Bulb
65.3 Wet Bulb (60% RH)
25,000
437
-23
74.4
0.04
448
-15
72.2
0.04
451
-12
72.8
0.04
462
-2
71.6
0.04
467
5
71.5
0.04
482
21
68.6
0.04

30,000
457
7
74.2
0.06
469
15
72.4
0.06
471
16
73.1
0.06
481
29
72.1
0.06
485
38
72.1
0.06
501
55
69.2
0.06

35,000
472
37
74.4
0.07
483
48
72.7
0.07
485
51
73.5
0.07
494
62
72.5
0.07
498
72
72.6
0.07
514
91
69.8
0.07

40,000
483
73
74.4
0.09
494
82
72.8
0.09
495
84
73.7
0.09
505
99
72.8
0.09
507
110
72.9
0.09
525
129
70.1
0.09

35,000
522
-201
78.9
0.07
534
-188
77.3
0.07
532
-183
78.3
0.07
540
-169
77.6
0.07
541
-158
77.9
0.07
559
-136
75.1
0.07

40,000
534
-185
79.0
0.09
546
-174
77.4
0.09
544
-172
78.3
0.09
551
-157
77.7
0.09
552
-145
78.1
0.09
570
-122
75.3
0.09

75 Dry Bulb
70.5 Wet Bulb (80% RH)
25,000
486
-210
78.7
0.01
497
-201
77.0
0.02
497
-200
77.8
0.02
507
-187
76.9
0.02
509
-177
77.1
0.02
526
-158
74.2
0.02

30,000
507
-208
78.8
0.04
519
-196
77.1
0.05
518
-196
78.0
0.05
526
-180
77.3
0.05
528
-169
77.5
0.05
545
-148
74.7
0.05

6. SHC values provided reflect maximum reheat values with 100%


gas bypass. Negative SHC value indicates that the air entering
the coil is being heated at 100% gas bypass. The P Series innovative modulating valve system will reduce the gas bypass as
required to meet the supply air setpoint with minimal change in
latent capacity. The space will NOT be overheated and the unit
will provide variable SHC to meet the space load.

FAN PERFORMANCE 48P2,P3,P4,P5030 AND 50P2,P3030 UNITS WITHOUT DISCHARGE PLENUM*


AIRFLOW
(cfm)
6,000
7,500
9,000
10,500
12,000
13,500
15,000

AIRFLOW
(cfm)
6,000
7,500
9,000
10,500
12,000
13,500
15,000

AIRFLOW
(cfm)
6,000
7,500
9,000
10,500
12,000
13,500
15,000

0.2
Rpm
222
248
278
311
344
379
415

0.4
Bhp
0.59
0.94
1.46
2.16
3.08
4.25
5.69

Rpm
284
300
323
349
378
410
442

1.8
Rpm
567
575
581
588
598
610
626

Bhp
3.84
4.57
5.38
6.31
7.41
8.71
10.25

Bhp
0.91
1.28
1.80
2.52
3.44
4.62
6.06

2.0
Rpm
595
604
611
617
625
637
651

Bhp
4.30
5.10
5.97
6.95
8.08
9.41
10.98

AVAILABLE EXTERNAL STATIC PRESSURE (in. wg)


0.6
0.8
1.0
1.2
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
339
1.27
388
1.66
430
2.07
469
2.50
350
1.68
395
2.11
437
2.57
475
3.05
366
2.22
407
2.69
446
3.19
483
3.71
387
2.95
424
3.43
459
3.96
493
4.51
412
3.89
445
4.39
477
4.93
508
5.51
440
5.07
469
5.58
498
6.13
527
6.73
470
6.52
496
7.04
523
7.61
549
8.22
AVAILABLE EXTERNAL STATIC PRESSURE (in. wg)
2.2
2.4
2.6
2.8
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
622
4.78
647
5.26
671
5.75
695
6.25
632
5.63
658
6.18
683
6.73
707
7.29
639
6.56
665
7.16
691
7.78
715
8.40
645
7.59
672
8.25
697
8.92
722
9.59
652
8.77
679
9.47
704
10.19
728
10.91
662
10.14
687
10.88
712
11.63
736
12.40
675
11.74
699
12.51
723
13.30
746
14.10

1.4

1.6

Rpm
504
511
517
526
539
555
575

Bhp
2.93
3.54
4.25
5.10
6.12
7.36
8.87

Rpm
536
544
550
558
569
583
601

Bhp
6.76
7.86
9.03
10.28
11.65
13.18
14.92

Rpm
738
752
761
769
775
782
790

3.0
Rpm
717
730
739
746
752
759
768

Bhp
3.38
4.05
4.81
5.70
6.75
8.02
9.55

3.2
Bhp
7.27
8.43
9.66
10.97
12.39
13.98
15.75

AVAILABLE EXTERNAL STATIC PRESSURE (in. wg)


3.4
3.6
3.8
4.0
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
759
7.79
779
8.32
799
8.85
817
9.39
773
9.01
794
9.60
814
10.20
833
10.80
783
10.30
805
10.95
825
11.60
845
12.26
791
11.67
812
12.38
833
13.09
854
13.81
797
13.15
819
13.91
840
14.68
860
15.45
804
14.77
825
15.59
846
16.41
867
17.23
812
16.59
833
17.45
853
18.31
874
19.19

LEGEND
48/50P3,P5 units only.
Bhp Brake Horsepower
*If calculating static pressure for a 48 Series unit, be sure to add gas
heat pressure drop from Component Pressure Drop table.
NOTES:
1. Fan performance is based on wet coils and clean 2-in. filters.

2. See Component Pressure Drop data table before using Fan Performance tables.
3. Conversion Bhp to kW:
Kilowatts =

Bhp x .746
Motor efficiency

See Physical Data table for motor efficiency.

103

Performance data (cont)


FAN PERFORMANCE 48P2,P3,P4,P5035 AND 50P2,P3035 UNITS WITHOUT DISCHARGE PLENUM*
AIRFLOW
(cfm)

0.2
Rpm
Bhp
246
0.84
266
1.14
310
1.98
357
3.20
406
4.87
430
5.89

7,000
8,000
10,000
12,000
14,000
15,000

AIRFLOW
(cfm)
7,000
8,000
10,000
12,000
14,000
15,000

AIRFLOW
(cfm)
7,000
8,000
10,000
12,000
14,000
15,000

0.4
Rpm
Bhp
301
1.19
315
1.50
350
2.36
390
3.60
435
5.28
458
6.31

1.8
Rpm
577
583
594
609
629
641

Bhp
4.40
4.94
6.16
7.67
9.57
10.69

2.0
Rpm
606
612
623
636
655
666

Bhp
4.91
5.49
6.79
8.36
10.30
11.44

AVAILABLE EXTERNAL STATIC PRESSURE (in. wg)


0.6
0.8
1.0
1.2
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
352
1.58
398
2.01
440
2.46
479
2.93
362
1.92
406
2.37
447
2.85
484
3.35
389
2.80
427
3.30
464
3.83
499
4.38
424
4.06
457
4.58
489
5.15
520
5.74
463
5.76
492
6.30
520
6.89
548
7.52
485
6.80
511
7.35
538
7.95
564
8.59
AVAILABLE EXTERNAL STATIC PRESSURE (in. wg)
2.2
2.4
2.6
2.8
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
633
5.43
659
5.95
684
6.49
707
7.03
640
6.05
666
6.62
691
7.19
715
7.78
651
7.42
677
8.07
703
8.73
727
9.39
663
9.05
689
9.77
714
10.49
738
11.22
680
11.04
704
11.81
728
12.59
751
13.38
690
12.20
714
12.99
737
13.79
760
14.61

1.6
Rpm
Bhp
547
3.90
552
4.39
564
5.55
580
7.01
603
8.86
616
9.96

3.0
Rpm
730
738
751
762
774
782

Bhp
7.58
8.37
10.06
11.97
14.18
15.44

3.2
Rpm
752
760
774
785
796
804

Bhp
8.14
8.97
10.74
12.72
14.99
16.28

AVAILABLE EXTERNAL STATIC PRESSURE (in. wg)


3.4
3.6
3.8
4.0
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
773
8.70
793
9.27
813
9.85
832
10.43
782
9.57
802
10.18
823
10.80
842
11.43
796
11.42
817
12.11
838
12.81
858
13.52
807
13.48
828
14.25
849
15.02
869
15.80
818
15.82
840
16.66
860
17.50
880
18.35
825
17.13
846
18.00
866
18.87
886
19.76

LEGEND
48/50P3,P5 units only.
Bhp Brake Horsepower
*If calculating static pressure for a 48 Series unit, be sure to add gas
heat pressure drop from Component Pressure Drop table.
NOTES:
1. Fan performance is based on wet coils and clean 2-in. filters.

104

1.4
Rpm
Bhp
514
3.40
519
3.87
532
4.96
551
6.36
576
8.18
590
9.26

2. See Component Pressure Drop data table before using Fan Performance tables.
3. Conversion Bhp to kW:
Kilowatts =

Bhp x .746
Motor efficiency

See Physical Data table for motor efficiency.

FAN PERFORMANCE 48P2,P3,P4,P5040 AND 50P2,P3040 UNITS WITHOUT DISCHARGE PLENUM*


AIRFLOW
(cfm)
8,000
10,000
12,000
14,000
16,000
18,000
20,000

AIRFLOW
(cfm)
8,000
10,000
12,000
14,000
16,000
18,000
20,000

AIRFLOW
(cfm)
8,000
10,000
12,000
14,000
16,000
18,000
20,000

0.2
Rpm
252
290
330
372
415
459
503

Bhp
0.98
1.67
2.65
3.96
5.67
7.84
10.51

0.4
Rpm
303
333
369
407
447
488
530

1.8
Rpm
571
579
590
607
629
656
687

Bhp
4.60
5.75
7.21
9.07
11.41
14.28
17.71

Bhp
1.33
2.11
3.18
4.61
6.44
8.72
11.51

2.0
Rpm
600
608
618
633
653
678
707

Bhp
5.14
6.36
7.87
9.78
12.16
15.09
18.60

AVAILABLE EXTERNAL STATIC PRESSURE (in. wg)


0.6
0.8
1.0
1.2
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
350
1.72
394
2.14
434
2.58
472
3.06
373
2.55
412
3.01
448
3.51
483
4.03
404
3.70
438
4.23
470
4.78
501
5.35
439
5.22
469
5.83
498
6.44
526
7.07
476
7.15
504
7.85
530
8.54
556
9.24
515
9.55
541
10.34
565
11.12
589
11.91
555
12.46
579
13.36
602
14.24
624
15.11

Rpm
507
517
532
554
581
612
645

AVAILABLE EXTERNAL STATIC PRESSURE (in. wg)


2.2
2.4
2.6
2.8
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
628
5.70
654
6.27
679
6.85
703
7.44
636
6.98
662
7.62
688
8.28
712
8.94
645
8.55
671
9.25
696
9.96
720
10.69
658
10.51
683
11.25
707
12.02
730
12.80
676
12.94
699
13.73
722
14.54
744
15.37
700
15.91
721
16.76
742
17.62
762
18.49
727
19.48
747
20.38
766
21.30
785
22.22

Rpm
726
736
744
753
766
783
804

1.4
Bhp
3.55
4.58
5.94
7.72
9.95
12.69
15.98

1.6
Rpm
540
549
562
581
605
634
666

3.0
Bhp
8.04
9.62
11.43
13.60
16.22
19.39
23.17

Bhp
4.07
5.16
6.56
8.38
10.67
13.47
16.84

3.2
Rpm
748
758
766
775
787
803

Bhp
8.65
10.30
12.19
14.41
17.08
20.29

AVAILABLE EXTERNAL STATIC PRESSURE (in. wg)


3.4
3.6
3.8
4.0
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
770
9.27
791
9.90
811
10.54
830
11.18
780
11.00
802
11.71
822
12.43
842
13.15
789
12.96
810
13.73
831
14.52
851
15.32
797
15.24
818
16.07
839
16.93
859
17.79
808
17.95
828
18.85
849
19.75
868
20.67
823
21.21
842
22.15
862
23.11

LEGEND
48/50P3,P5 units only.
Bhp Brake Horsepower
*If calculating static pressure for a 48 Series unit, be sure to add gas
heat pressure drop from Component Pressure Drop table.
NOTES:
1. Fan performance is based on wet coils and clean 2-in. filters.

2. See Component Pressure Drop data table before using Fan Performance tables.
3. Conversion Bhp to kW:
Kilowatts =

Bhp x .746
Motor efficiency

See Physical Data table for motor efficiency.

105

Performance data (cont)


FAN PERFORMANCE 48P2,P3,P4,P5050 AND 50P2,P3050 UNITS WITHOUT DISCHARGE PLENUM*
AIRFLOW
(cfm)
9,000
10,000
12,000
14,000
16,000
18,000
20,000

AIRFLOW
(cfm)
9,000
10,000
12,000
14,000
16,000
18,000
20,000

AIRFLOW
(cfm)
9,000
10,000
12,000
14,000
16,000
18,000
20,000

0.2
Rpm
276
296
339
382
427
473
519

Bhp
1.34
1.74
2.76
4.15
5.96
8.26
11.10

0.4
Rpm
323
339
376
416
458
501
545

1.8
Rpm
579
584
597
615
639
667
699

Bhp
5.23
5.85
7.36
9.29
11.71
14.69
18.25

Bhp
1.73
2.17
3.29
4.79
6.71
9.12
12.06

2.0
Rpm
608
613
625
641
663
689
719

Bhp
5.81
6.47
8.03
10.01
12.48
15.51
19.14

AVAILABLE EXTERNAL STATIC PRESSURE (in. wg)


0.6
0.8
1.0
1.2
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
366
2.15
407
2.60
445
3.08
482
3.58
379
2.62
418
3.09
454
3.59
489
4.12
411
3.81
445
4.35
477
4.91
509
5.49
448
5.40
478
6.01
506
6.63
535
7.26
487
7.42
514
8.11
540
8.81
565
9.52
527
9.93
552
10.72
576
11.50
600
12.29
570
12.99
593
13.88
615
14.76
637
15.63

Rpm
516
522
539
562
590
623
658

AVAILABLE EXTERNAL STATIC PRESSURE (in. wg)


2.2
2.4
2.6
2.8
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
636
6.41
662
7.02
687
7.64
712
8.27
641
7.10
667
7.74
692
8.40
717
9.07
651
8.72
677
9.42
702
10.14
726
10.88
666
10.74
690
11.50
714
12.27
738
13.06
686
13.27
709
14.07
731
14.89
753
15.73
711
16.35
732
17.20
753
18.07
773
18.96
739
20.04
759
20.95
778
21.88
797
22.82

Rpm
735
740
750
760
775
793
816

Bhp
4.11
4.68
6.09
7.92
10.23
13.08
16.50

1.6
Rpm
549
554
568
589
615
645
679

3.0
Bhp
8.91
9.75
11.63
13.87
16.58
19.86
23.77

Bhp
4.66
5.26
6.71
8.60
10.97
13.88
17.38

3.2
Rpm
757
763
772
783
796
813

Bhp
9.57
10.44
12.39
14.69
17.45
20.78

AVAILABLE EXTERNAL STATIC PRESSURE (in. wg)


3.4
3.6
3.8
4.0
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
779
10.23
800
10.90
821
11.58
840
12.27
785
11.14
806
11.85
826
12.57
846
13.30
794
13.16
816
13.94
836
14.73
857
15.54
804
15.52
825
16.37
846
17.22
866
18.10
817
18.34
837
19.24
857
20.15
877
21.08
833
21.71
853
22.66
872
23.62

LEGEND
48/50P3,P5 units only.
Bhp Brake Horsepower
*If calculating static pressure for a 48 Series unit, be sure to add gas
heat pressure drop from Component Pressure Drop table.
NOTES:
1. Fan performance is based on wet coils and clean 2-in. filters.

106

1.4

2. See Component Pressure Drop data table before using Fan Performance tables.
3. Conversion Bhp to kW:
Kilowatts =

Bhp x .746
Motor efficiency

See Physical Data table for motor efficiency.

FAN PERFORMANCE 48P2,P3,P4,P5055 AND 50P2,P3055 UNITS WITHOUT DISCHARGE PLENUM*


AIRFLOW
(cfm)
10,000
12,500
15,000
17,500
20,000
22,500
25,000

0.2
Rpm Bhp
207
1.04
235
1.69
265
2.59
295
3.78
327
5.31
359
7.23
392
9.59

AIRFLOW
(cfm)

1.8

10,000
12,500
15,000
17,500
20,000
22,500
25,000

AIRFLOW
(cfm)
10,000
12,500
15,000
17,500
20,000
22,500
25,000

Rpm
497
497
501
512
528
548
571

Bhp
7.27
7.73
8.63
10.09
12.09
14.60
17.63

0.4
Rpm
253
276
302
331
360
390
421

Bhp
1.50
2.23
3.23
4.52
6.15
8.16
10.60

2.0
Rpm
523
523
526
535
549
567
589

Bhp
8.39
8.83
9.67
11.07
13.06
15.59
18.66

AVAILABLE EXTERNAL STATIC PRESSURE (in. wg)


0.6
0.8
1.0
1.2
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
295
2.03
334
2.66
371
3.41
405
4.26
312
2.78
346
3.40
379
4.10
410
4.88
335
3.85
365
4.51
394
5.20
422
5.96
361
5.24
389
5.97
415
6.71
440
7.48
388
6.98
414
7.79
439
8.60
462
9.43
417
9.09
442
10.00
465
10.90
487
11.81
447
11.62
470
12.64
492
13.64
513
14.63

Rpm
438
440
449
465
485
508
533

AVAILABLE EXTERNAL STATIC PRESSURE (in. wg)


2.2
2.4
2.6
2.8
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
549
9.55
573
10.75
596
11.98
618
13.23
549
10.00
573
11.22
597
12.49
619
13.81
550
10.77
574
11.94
597
13.17
619
14.46
557
12.11
579
13.21
601
14.38
622
15.60
570
14.07
590
15.12
610
16.24
630
17.40
587
16.61
605
17.66
624
18.75
642
19.88
607
19.71
624
20.78
642
21.89
659
23.02

Rpm
639
641
641
643
649
660
676

1.4
Bhp
5.20
5.75
6.78
8.30
10.28
12.72
15.62

1.6
Rpm
468
469
476
489
507
528
552

3.0
Bhp
14.51
15.16
15.80
16.88
18.62
21.06
24.19

Bhp
6.20
6.70
7.67
9.17
11.17
13.65
16.62

3.2
Rpm
659
662
662
663
668
678
692

Bhp
15.81
16.55
17.19
18.21
19.89
22.28
25.39

AVAILABLE EXTERNAL STATIC PRESSURE (in. wg)


3.4
3.6
3.8
4.0
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
679
17.13
697
18.46
715
19.81
733
21.17
682
17.98
702
19.43
721
20.90
739
22.40
682
18.63
702
20.10
721
21.62
740
23.17
683
19.60
702
21.04
721
22.53
740
24.06
687
21.20
706
22.57
724
24.00
742
25.46
696
23.55
713
24.86
731
26.22
748
27.62
709
26.62
725
27.91
741
29.22

LEGEND
48/50P3,P5 units only.
Bhp Brake Horsepower
*If calculating static pressure for a 48 Series unit, be sure to add gas
heat pressure drop from Component Pressure Drop table.
NOTES:
1. Fan performance is based on wet coils and clean 2-in. filters.

2. See Component Pressure Drop data table before using Fan Performance tables.
3. Conversion Bhp to kW:
Kilowatts =

Bhp x .746
Motor efficiency

See Physical Data table for motor efficiency.

107

Performance data (cont)


FAN PERFORMANCE 48P2,P3,P4,P5060 AND 50P2,P3060 UNITS WITHOUT DISCHARGE PLENUM*
AIRFLOW
(cfm)
12,000
15,000
18,000
21,000
24,000
27,000
30,000

AIRFLOW
(cfm)
12,000
15,000
18,000
21,000
24,000
27,000
30,000

AIRFLOW
(cfm)
12,000
15,000
18,000
21,000
24,000
27,000
30,000

0.2
Rpm
234
271
308
348
390
433
476

Bhp
1.54
2.65
4.22
6.36
9.19
12.80
17.29

0.4
Rpm
276
309
344
380
417
456
497

1.8
Rpm
504
509
521
543
570
601
634

Bhp
7.56
8.87
10.79
13.56
17.22
21.81
27.34

Bhp
2.03
3.27
5.00
7.29
10.24
13.93
18.50

2.0
Rpm
530
535
544
563
588
618
650

Bhp
8.57
9.95
11.85
14.60
18.28
22.93
28.56

AVAILABLE EXTERNAL STATIC PRESSURE (in. wg)


0.6
0.8
1.0
1.2
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
312
2.57
348
3.20
382
3.93
415
4.74
341
3.88
370
4.53
399
5.24
428
6.04
374
5.73
400
6.46
426
7.22
450
8.02
408
8.18
434
9.04
457
9.88
479
10.74
444
11.29
469
12.29
491
13.27
512
14.23
481
15.14
504
16.30
526
17.44
546
18.53
519
19.82
541
21.15
562
22.45
581
23.70

Rpm
446
455
474
501
532
565
599

AVAILABLE EXTERNAL STATIC PRESSURE (in. wg)


2.2
2.4
2.6
2.8
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
555
9.61
578
10.66
600
11.73
621
12.81
559
11.07
583
12.25
606
13.45
628
14.68
567
12.97
590
14.14
612
15.38
633
16.66
583
15.69
603
16.84
623
18.05
643
19.31
607
19.39
625
20.53
642
21.72
660
22.95
635
24.07
651
25.25
667
26.46
684
27.70
666
29.78
681
31.02
696
32.28
711
33.56

Rpm
641
650
654
662
678
700
726

Bhp
5.63
6.91
8.88
11.64
15.21
19.62
24.93

1.6
Rpm
476
482
498
522
551
583
617

3.0
Bhp
13.91
15.95
17.99
20.63
24.24
28.98
34.88

Bhp
6.58
7.85
9.81
12.58
16.20
20.71
26.14

3.2
Rpm
660
670
675
682
695
715

Bhp
15.01
17.23
19.36
21.99
25.58
30.31

AVAILABLE EXTERNAL STATIC PRESSURE (in. wg)


3.4
3.6
3.8
4.0
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
679
16.11
697
17.23
714
18.35
730
19.49
690
18.52
709
19.84
727
21.15
745
22.49
695
20.76
714
22.20
733
23.66

701
23.41
719
24.87
738
26.38

713
26.97
730
28.40
747
29.89

731
31.67
747
33.08

LEGEND
48/50P3,P5 units only.
Bhp Brake Horsepower
*If calculating static pressure for a 48 Series unit, be sure to add gas
heat pressure drop from Component Pressure Drop table.
NOTES:
1. Fan performance is based on wet coils and clean 2-in. filters.

108

1.4

2. See Component Pressure Drop data table before using Fan Performance tables.
3. Conversion Bhp to kW:
Kilowatts =

Bhp x .746
Motor efficiency

See Physical Data table for motor efficiency.

FAN PERFORMANCE 48P2,P3,P4,P5070 AND 50P2,P3070 UNITS WITHOUT DISCHARGE PLENUM*


AIRFLOW
(cfm)
14,000
17,500
21,000
24,500
28,000
30,000

AIRFLOW
(cfm)
14,000
17,500
21,000
24,500
28,000
30,000

AIRFLOW
(cfm)
14,000
17,500
21,000
24,500
28,000
30,000

0.2
Rpm
258
302
348
397
447
476

Bhp
2.23
3.92
6.36
9.74
14.18
17.29

0.4
Rpm
297
338
380
424
470
497

1.8
Rpm
507
519
543
575
612
634

Bhp
8.39
10.42
13.56
17.93
23.55
27.34

Bhp
2.80
4.67
7.29
10.80
15.35
18.50

2.0
Rpm
533
542
563
593
628
650

Bhp
9.46
11.48
14.60
18.99
24.69
28.56

AVAILABLE EXTERNAL STATIC PRESSURE (in. wg)


0.6
0.8
1.0
1.2
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
330
3.38
362
4.02
392
4.73
422
5.53
368
5.39
395
6.10
421
6.84
446
7.64
408
8.18
434
9.04
457
9.88
479
10.74
450
11.88
475
12.91
497
13.91
517
14.89
494
16.60
516
17.82
538
19.01
558
20.16
519
19.82
541
21.15
562
22.45
581
23.70

Rpm
451
471
501
537
576
599

AVAILABLE EXTERNAL STATIC PRESSURE (in. wg)


2.2
2.4
2.6
2.8
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
558
10.57
582
11.71
605
12.89
627
14.08
565
12.60
588
13.78
610
15.02
632
16.30
583
15.69
603
16.84
623
18.05
643
19.31
611
20.10
629
21.24
646
22.43
664
23.67
645
25.86
661
27.05
677
28.27
692
29.53
666
29.78
681
31.02
696
32.28
711
33.56

Rpm
648
653
662
681
708
726

1.4
Bhp
6.42
8.50
11.64
15.88
21.29
24.93

1.6
Rpm
480
495
522
556
594
617

3.0
Bhp
15.29
17.62
20.63
24.96
30.82
34.88

Bhp
7.37
9.42
12.57
16.89
22.41
26.14

3.2
Rpm
668
674
682
698
723

Bhp
16.52
18.99
21.99
26.29
32.15

AVAILABLE EXTERNAL STATIC PRESSURE (in. wg)


3.4
3.6
3.8
4.0
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
687
17.76
706
19.01
724
20.27
741
21.54
694
20.38
713
21.79
732
23.24

701
23.41
719
24.87
738
26.38

715
27.67
732
29.10
749
30.58

739
33.51

LEGEND
48/50P3,P5 units only.
Bhp Brake Horsepower
*If calculating static pressure for a 48 Series unit, be sure to add gas
heat pressure drop from Component Pressure Drop table.
NOTES:
1. Fan performance is based on wet coils and clean 2-in. filters.

2. See Component Pressure Drop data table before using Fan Performance tables.
3. Conversion Bhp to kW:
Kilowatts =

Bhp x .746
Motor efficiency

See Physical Data table for motor efficiency.

109

Performance data (cont)


FAN PERFORMANCE 50P2,P3030 UNITS WITH DISCHARGE PLENUM AND 50P4,P5030 UNITS
AIRFLOW
(cfm)
6,000
7,500
9,000
10,500
12,000
13,500
15,000

0.2
Rpm Bhp
255
0.95
291
1.51
330
2.28
371
3.28
413
4.56
456
6.12
500
7.99

AIRFLOW
(cfm)

1.8

6,000
7,500
9,000
10,500
12,000
13,500
15,000

AIRFLOW
(cfm)
6,000
7,500
9,000
10,500
12,000
13,500
15,000

Rpm
594
605
617
633
652
676
703

Bhp
5.43
6.16
7.02
8.12
9.52
11.25
13.30

0.4
Rpm Bhp
313
1.35
340
1.93
372
2.73
408
3.76
447
5.07
487
6.66
528
8.58

2.0
Rpm
623
635
646
660
679
701
726

Bhp
6.09
6.88
7.76
8.86
10.27
12.00
14.07

AVAILABLE EXTERNAL STATIC PRESSURE (in. wg)


0.6
0.8
1.0
1.2
Rpm Bhp Rpm Bhp Rpm
Bhp
Rpm
Bhp
364
1.82
411
2.35
454
2.92
494
3.52
386
2.41
428
2.94
468
3.51
505
4.13
413
3.22
451
3.76
487
4.34
522
4.96
444
4.28
479
4.84
512
5.43
544
6.06
479
5.61
510
6.19
540
6.80
570
7.44
516
7.23
544
7.83
572
8.46
599
9.12
555
9.18
581
9.80
606
10.45
631
11.13
AVAILABLE EXTERNAL STATIC PRESSURE (in. wg)
2.2
2.4
2.6
2.8
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
651
6.75
676
7.41
701
8.08
725
8.75
664
7.62
691
8.36
716
9.11
741
9.88
674
8.52
702
9.31
728
10.11
753
10.93
687
9.64
713
10.43
739
11.25
764
12.09
704
11.04
729
11.84
753
12.66
777
13.50
725
12.78
748
13.58
771
14.40
794
15.24
749
14.86
771
15.66
793
16.49
814
17.34

1.4
Rpm
530
541
555
574
598
626
656

1.6

Bhp
4.14
4.78
5.61
6.71
8.11
9.81
11.83

3.0
Rpm
747
765
777
788
800
816
835

Bhp
9.42
10.64
11.76
12.95
14.37
16.11
18.20

Bhp
4.78
5.46
6.30
7.40
8.80
10.51
12.56

3.2
Rpm
769
787
800
811
823
838
856

Bhp
10.10
11.41
12.60
13.82
15.26
16.99
19.09

AVAILABLE EXTERNAL STATIC PRESSURE (in. wg)


3.4
3.6
3.8
4.0
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
789
10.77
809
11.45
829
12.13
848
12.81
809
12.18
830
12.96
851
13.73
870
14.51
823
13.44
844
14.29
866
15.15
886
16.01
833
14.71
856
15.61
877
16.52
898
17.44
845
16.16
867
17.08
888
18.01

859
17.90
880
18.82

876
20.00
896
20.92

LEGEND
50P3,P5 units only.
Bhp Brake Horsepower
NOTES:
1. Fan performance is based on wet coils and clean 2-in. filters.

2. See Component Pressure Drop data table before using Fan Performance tables.
3. Conversion Bhp to kW:
Kilowatts =

Bhp x .746
Motor efficiency

See Physical Data Table for motor efficiency.

110

Rpm
563
574
587
604
626
651
680

FAN PERFORMANCE 50P2,P3035 UNITS WITH DISCHARGE PLENUM AND 50P4,P5035 UNITS
AIRFLOW
(cfm)
7,000
8,000
10,000
12,000
14,000
15,000

0.2
Rpm Bhp
285
1.35
311
1.81
367
3.04
426
4.74
486
6.98
517
8.33

AIRFLOW
(cfm)

1.8

7,000
8,000
10,000
12,000
14,000
15,000

AIRFLOW
(cfm)
7,000
8,000
10,000
12,000
14,000
15,000

Rpm
607
615
636
663
698
718

Bhp
6.03
6.58
7.94
9.83
12.31
13.78

0.4
Rpm Bhp
337
1.78
358
2.25
406
3.52
459
5.26
515
7.55
544
8.92

2.0
Rpm
637
645
664
689
722
741

Bhp
6.74
7.32
8.70
10.59
13.08
14.56

AVAILABLE EXTERNAL STATIC PRESSURE (in. wg)


0.6
0.8
1.0
1.2
Rpm Bhp Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
384
2.26
428
2.80
469
3.38
507
4.00
402
2.75
442
3.29
481
3.87
517
4.50
443
4.05
479
4.61
512
5.21
545
5.84
491
5.82
522
6.42
552
7.05
581
7.70
543
8.15
570
8.78
597
9.44
623
10.12
570
9.54
596
10.18
621
10.85
646
11.55
AVAILABLE EXTERNAL STATIC PRESSURE (in. wg)
2.2
2.4
2.6
2.8
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
665
7.46
691
8.18
717
8.91
741
9.65
673
8.07
700
8.84
726
9.62
751
10.41
691
9.48
717
10.29
743
11.11
768
11.96
715
11.38
739
12.19
764
13.03
787
13.88
745
13.88
768
14.69
791
15.53
813
16.39
763
15.36
785
16.19
807
17.03
828
17.90

1.4
Rpm
542
551
576
609
649
671

1.6

Bhp
4.66
5.16
6.51
8.38
10.83
12.27

Rpm
576
584
606
637
674
694

3.0
Rpm
764
775
792
810
834
849

Bhp
10.39
11.20
12.82
14.76
17.27
18.78

Bhp
5.34
5.86
7.21
9.09
11.55
13.01

3.2
Rpm
786
797
815
833
856
869

Bhp
11.13
12.00
13.69
15.66
18.17
19.69

AVAILABLE EXTERNAL STATIC PRESSURE (in. wg)


3.4
3.6
3.8
4.0
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
807
11.88
828
12.62
848
13.37
867
14.12
819
12.80
841
13.61
861
14.42
881
15.23
837
14.57
859
15.47
881
16.37

855
16.57
876
17.51
897
18.45

876
19.10
897
20.04

890
20.61

LEGEND
50P3,P5 units only.
Bhp Brake Horsepower
NOTES:
1. Fan performance is based on wet coils and clean 2-in. filters.

2. See Component Pressure Drop data table before using Fan Performance tables.
3. Conversion Bhp to kW:
Kilowatts =

Bhp x .746
Motor efficiency

See Physical Data table for motor efficiency.

111

Performance data (cont)


FAN PERFORMANCE 50P2,P3040 UNITS WITH DISCHARGE PLENUM AND 50P4,P5040 UNITS
AIRFLOW
(cfm)
8,000
10,000
12,000
14,000
16,000
18,000
20,000

AIRFLOW
(cfm)
8,000
10,000
12,000
14,000
16,000
18,000
20,000

AIRFLOW
(cfm)
8,000
10,000
12,000
14,000
16,000
18,000
20,000

0.2
Rpm
293
343
395
449
504
559
615

Bhp
1.62
2.66
4.09
5.97
8.32
11.20
14.66

0.4
Rpm
344
385
431
481
533
586
640

1.8
Rpm
603
623
648
677
712
749
790

Bhp
6.23
7.70
9.50
11.73
14.45
17.73
21.61

Bhp
2.10
3.19
4.68
6.62
9.06
12.04
15.59

2.0
Rpm
632
651
674
702
735
771
811

Bhp
6.87
8.41
10.26
12.54
15.30
18.61
22.52

AVAILABLE EXTERNAL STATIC PRESSURE (in. wg)


0.6
0.8
1.0
1.2
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
390
2.62
432
3.18
470
3.76
507
4.36
425
3.76
463
4.36
498
4.99
532
5.64
466
5.29
500
5.93
532
6.60
562
7.30
512
7.28
541
7.96
570
8.67
598
9.40
560
9.77
587
10.50
613
11.25
638
12.02
611
12.82
635
13.59
659
14.38
682
15.19
663
16.44
685
17.28
707
18.11
728
18.96

Rpm
541
563
592
626
663
705
749

AVAILABLE EXTERNAL STATIC PRESSURE (in. wg)


2.2
2.4
2.6
2.8
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
659
7.50
685
8.14
710
8.78
734
9.43
678
9.13
703
9.86
728
10.60
752
11.33
699
11.04
724
11.83
748
12.63
772
13.44
726
13.35
750
14.19
772
15.04
795
15.89
757
16.16
779
17.03
801
17.92
822
18.82
792
19.50
813
20.42
833
21.34
853
22.27
830
23.45

Rpm
757
776
794
817
843
873

1.4
Bhp
4.97
6.31
8.01
10.16
12.81
16.01
19.83

3.0
Bhp
10.07
12.08
14.25
16.76
19.73
23.23

Bhp
5.60
7.00
8.75
10.93
13.62
16.86
20.71

3.2
Rpm
779
798
817
838
863

Bhp
10.71
12.82
15.07
17.64
20.65

AVAILABLE EXTERNAL STATIC PRESSURE (in. wg)


3.4
3.6
3.8
4.0
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
800
11.35
821
12.00
841
12.64
860
13.28
820
13.57
841
14.31
862
15.06
882
15.81
838
15.90
859
16.73
880
17.57
900
18.40
859
18.53
879
19.42
899
20.32

883
21.58

LEGEND
50P3,P5 units only.
Bhp Brake Horsepower
NOTES:
1. Fan performance is based on wet coils and clean 2-in. filters.

2. See Component Pressure Drop data table before using Fan Performance tables.
3. Conversion Bhp to kW:
Kilowatts =

Bhp x .746
Motor efficiency

See Physical Data table for motor efficiency.

112

1.6
Rpm
573
594
620
652
688
727
770

FAN PERFORMANCE 50P2,P3050 UNITS WITH DISCHARGE PLENUM AND 50P4,P5050 UNITS
AIRFLOW
(cfm)
9,000
10,000
12,000
14,000
16,000
18,000
20,000

AIRFLOW
(cfm)
9,000
10,000
12,000
14,000
16,000
18,000
20,000

AIRFLOW
(cfm)
9,000
10,000
12,000
14,000
16,000
18,000
20,000

0.2
Rpm
324
349
403
459
515
573
630

Bhp
2.15
2.74
4.23
6.17
8.63
11.65
15.28

0.4
Rpm
369
392
439
490
544
599
654

1.8
Rpm
617
628
654
686
721
761
803

Bhp
7.08
7.87
9.74
12.06
14.88
18.27
22.27

Bhp
2.67
3.28
4.82
6.83
9.34
12.44
16.14

2.0
Rpm
645
656
680
710
744
782
823

Bhp
7.77
8.59
10.51
12.88
15.74
19.17
23.21

AVAILABLE EXTERNAL STATIC PRESSURE (in. wg)


0.6
0.8
1.0
1.2
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
412
3.23
452
3.83
488
4.44
523
5.08
431
3.87
469
4.48
504
5.12
537
5.78
474
5.45
507
6.11
539
6.80
570
7.51
521
7.50
550
8.20
579
8.93
607
9.69
571
10.07
597
10.82
623
11.59
649
12.38
623
13.21
647
14.00
671
14.82
694
15.65
677
16.97
699
17.81
720
18.66
741
19.53

Rpm
556
569
599
634
674
716
762

AVAILABLE EXTERNAL STATIC PRESSURE (in. wg)


2.2
2.4
2.6
2.8
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
672
8.47
698
9.18
723
9.90
747
10.62
682
9.33
708
10.07
733
10.82
757
11.58
706
11.30
730
12.10
754
12.90
778
13.73
734
13.71
757
14.55
780
15.41
802
16.27
767
16.62
789
17.51
810
18.41
831
19.32
803
20.09
824
21.02
844
21.96
864
22.92

Rpm
770
780
800
824
852
884

1.4
Bhp
5.73
6.46
8.23
10.46
13.20
16.50
20.43

1.6
Rpm
587
599
627
660
698
739
783

3.0
Bhp
11.34
12.35
14.56
17.15
20.24
23.88

Bhp
6.40
7.16
8.98
11.25
14.03
17.37
21.34

3.2
Rpm
793
802
822
845
872

Bhp
12.07
13.12
15.39
18.04
21.17

AVAILABLE EXTERNAL STATIC PRESSURE (in. wg)


3.4
3.6
3.8
4.0
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
814
12.79
835
13.52
855
14.25
875
14.99
824
13.89
845
14.67
866
15.45
886
16.23
844
16.24
865
17.09
885
17.95

866
18.94
886
19.85

892
22.12

LEGEND
50P3,P5 units only.
Bhp Brake Horsepower
NOTES:
1. Fan performance is based on wet coils and clean 2-in. filters.

2. See Component Pressure Drop data table before using Fan Performance tables.
3. Conversion Bhp to kW:
Kilowatts =

Bhp x .746
Motor efficiency

See Physical Data table for motor efficiency.

113

Performance data (cont)


FAN PERFORMANCE 50P2,P3055 UNITS WITH DISCHARGE PLENUM AND 50P4,P5055 UNITS
AIRFLOW
(cfm)
10,000
12,500
15,000
17,500
20,000
22,500
25,000

AIRFLOW
(cfm)
10,000
12,500
15,000
17,500
20,000
22,500
25,000

AIRFLOW
(cfm)
10,000
12,500
15,000
17,500
20,000
22,500
25,000

0.2
Rpm
217
248
281
315
351
389
427

Bhp
1.21
2.01
3.13
4.64
6.64
9.20
12.39

0.4
Rpm
258
286
317
348
381
414
449

1.8
Rpm
500
498
501
514
535
561
590

Bhp
7.48
8.63
10.03
12.05
14.76
18.17
22.27

Bhp
1.71
2.63
3.90
5.55
7.64
10.25
13.48

2.0
Rpm
527
525
526
536
554
579
606

Bhp
8.46
9.76
11.17
13.17
15.88
19.34
23.51

AVAILABLE EXTERNAL STATIC PRESSURE (in. wg)


0.6
0.8
1.0
1.2
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
296
2.29
334
2.97
371
3.76
407
4.63
319
3.26
349
3.95
380
4.71
410
5.58
347
4.64
374
5.38
400
6.18
425
7.03
378
6.43
403
7.29
426
8.16
449
9.05
409
8.68
433
9.68
456
10.66
477
11.64
440
11.43
464
12.59
486
13.71
506
14.81
473
14.75
496
16.06
517
17.34
537
18.59

Rpm
440
440
450
471
497
525
555

AVAILABLE EXTERNAL STATIC PRESSURE (in. wg)


2.2
2.4
2.6
2.8
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
552
9.45
576
10.44
598
11.42
619
12.41
552
10.93
577
12.12
601
13.32
624
14.54
550
12.38
575
13.65
598
14.97
621
16.32
557
14.35
579
15.60
600
16.91
621
18.28
573
17.06
592
18.29
611
19.58
630
20.91
596
20.54
613
21.78
629
23.06
646
24.40
622
24.78
637
26.07
653
27.39
668
28.75

Rpm
639
646
644
643
649
663
683

1.4
Bhp
5.56
6.52
7.95
10.00
12.65
15.91
19.82

3.0
Bhp
13.41
15.76
17.71
19.70
22.31
25.78
30.13

Bhp
6.51
7.54
8.95
10.99
13.68
17.03
21.04

3.2
Rpm
659
667
666
663
668
680
699

Bhp
14.41
16.99
19.11
21.18
23.77
27.20
31.56

AVAILABLE EXTERNAL STATIC PRESSURE (in. wg)


3.4
3.6
3.8
4.0
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
677
15.40
695
16.40
712
17.40
728
18.41
687
18.22
706
19.45
725
20.69
742
21.92
687
20.54
707
21.98
727
23.43
746
24.89
684
22.69
704
24.24
724
25.83
743
27.43
686
25.27
705
26.84
723
28.44
742
30.09
697
28.68
713
30.21
730
31.79
747
33.42
714
33.04
729
34.55

LEGEND
50P3,P5 units only.
Bhp Brake Horsepower
NOTES:
1. Fan performance is based on wet coils and clean 2-in. filters.

2. See Component Pressure Drop data table before using Fan Performance tables.
3. Conversion Bhp to kW:
Kilowatts =

Bhp x .746
Motor efficiency

See Physical Data table for motor efficiency.

114

1.6
Rpm
471
469
476
493
516
543
573

FAN PERFORMANCE 50P2,P3060 UNITS WITH DISCHARGE PLENUM AND 50P4,P5060 UNITS
AIRFLOW
(cfm)
12,000
15,000
18,000
21,000
24,000
27,000
30,000

AIRFLOW
(cfm)
12,000
15,000
18,000
21,000
24,000
27,000
30,000

AIRFLOW
(cfm)
12,000
15,000
18,000
21,000
24,000
27,000
30,000

0.2
Rpm
241
281
323
366
410
455
500

Bhp
1.82
3.14
5.03
7.61
10.97
15.23
20.52

0.4
Rpm
280
316
355
395
437
479
522

1.8
Rpm
486
498
518
546
577
611
648

Bhp
7.94
9.90
12.57
16.07
20.49
25.91
32.43

Bhp
2.41
3.87
5.92
8.66
12.20
16.65
22.11

2.0
Rpm
511
520
539
564
594
628
663

Bhp
8.91
10.93
13.66
17.23
21.74
27.26
33.90

AVAILABLE EXTERNAL STATIC PRESSURE (in. wg)


0.6
0.8
1.0
1.2
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
314
3.04
346
3.72
376
4.47
405
5.26
346
4.61
374
5.38
400
6.19
426
7.05
382
6.80
408
7.68
431
8.58
454
9.53
421
9.69
444
10.71
466
11.73
487
12.78
460
13.39
482
14.55
503
15.71
523
16.88
501
18.00
522
19.33
542
20.64
560
21.95
543
23.64
563
25.14
581
26.61
599
28.06

Rpm
433
450
476
507
541
578
616

AVAILABLE EXTERNAL STATIC PRESSURE (in. wg)


2.2
2.4
2.6
2.8
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
535
9.91
559
10.94
581
11.99
603
13.07
543
12.01
564
13.11
586
14.26
606
15.43
559
14.78
579
15.95
598
17.15
617
18.39
583
18.42
600
19.64
618
20.90
635
22.19
611
23.00
628
24.31
644
25.63
660
26.99
643
28.63
659
30.03
674
31.44
689
32.87
678
35.38

Rpm
624
627
636
653
676
703

1.4
Bhp
6.11
7.95
10.50
13.85
18.07
23.26
29.52

1.6
Rpm
460
474
498
527
560
595
632

3.0
Bhp
14.16
16.63
19.65
23.51
28.38
34.33

Bhp
7.01
8.90
11.52
14.94
19.27
24.58
30.97

3.2
Rpm
645
646
654
669
691
718

Bhp
15.28
17.86
20.95
24.86
29.77
35.82

AVAILABLE EXTERNAL STATIC PRESSURE (in. wg)


3.4
3.6
3.8
4.0
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
664
16.40
683
17.55
702
18.70
720
19.87
666
19.12
685
20.39
703
21.69
721
23.01
672
22.28
690
23.64
708
25.02
725
26.44
686
26.25
703
27.67
719
29.11
735
30.59
707
31.23
722
32.71
737
34.20

LEGEND
50P3,P5 units only.
Bhp Brake Horsepower
NOTES:
1. Fan performance is based on wet coils and clean 2-in. filters.

2. See Component Pressure Drop data table before using Fan Performance tables.
3. Conversion Bhp to kW:
Kilowatts =

Bhp x .746
Motor efficiency

See Physical Data table for motor efficiency.

115

Performance data (cont)


FAN PERFORMANCE 50P2,P3070 UNITS WITH DISCHARGE PLENUM AND 50P4,P5070 UNITS
AIRFLOW
(cfm)
14,000
17,500
21,000
24,500
28,000
30,000

AIRFLOW
(cfm)
14,000
17,500
21,000
24,500
28,000
30,000

AIRFLOW
(cfm)
14,000
17,500
21,000
24,500
28,000
30,000

0.2
Rpm
268
316
366
417
470
500

Bhp
2.64
4.67
7.61
11.61
16.88
20.52

0.4
Rpm
304
348
395
444
493
522

1.8
Rpm
493
515
546
583
623
648

Bhp
9.17
12.07
16.07
21.32
27.96
32.43

Bhp
3.32
5.54
8.66
12.87
18.35
22.11

2.0
Rpm
516
535
564
600
639
663

Bhp
10.19
13.14
17.23
22.59
29.35
33.90

AVAILABLE EXTERNAL STATIC PRESSURE (in. wg)


0.6
0.8
1.0
1.2
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
335
4.02
364
4.76
391
5.55
418
6.39
376
6.39
402
7.25
426
8.14
449
9.06
421
9.69
444
10.71
466
11.73
487
12.78
467
14.09
489
15.28
509
16.47
529
17.66
515
19.77
536
21.15
555
22.51
573
23.87
543
23.64
563
25.14
581
26.61
599
28.06

Rpm
444
472
507
547
590
616

AVAILABLE EXTERNAL STATIC PRESSURE (in. wg)


2.2
2.4
2.6
2.8
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
539
11.24
562
12.33
583
13.45
605
14.60
556
14.26
576
15.42
595
16.61
615
17.84
583
18.42
600
19.64
618
20.90
635
22.19
616
23.87
633
25.18
649
26.53
664
27.89
655
30.75
670
32.18
685
33.63
699
35.09
678
35.38

Rpm
625
634
653
680

1.4
Bhp
7.27
10.03
13.85
18.86
25.22
29.52

3.0
Bhp
15.77
19.09
23.51
29.29

Bhp
8.20
11.03
14.94
20.08
26.59
30.97

3.2
Rpm
645
652
669
695

Bhp
16.96
20.39
24.86
30.71

AVAILABLE EXTERNAL STATIC PRESSURE (in. wg)


3.4
3.6
3.8
4.0
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
665
18.18
684
19.42
703
20.68
721
21.95
671
21.70
689
23.05
706
24.42
724
25.82
686
26.24
703
27.67
719
29.11
735
30.59
711
32.17
726
33.65
741
35.16

LEGEND
50P3,P5 units only.
Bhp Brake Horsepower
NOTES:
1. Fan performance is based on wet coils and clean 2-in. filters.

2. See Component Pressure Drop data table before using Fan Performance tables.
3. Conversion Bhp to kW:
Kilowatts =

Bhp x .746
Motor efficiency

See Physical Data table for motor efficiency.

116

1.6
Rpm
468
493
527
565
607
632

FAN PERFORMANCE 48/50P2,P3,P4,P5075 UNITS WITH FORWARD-CURVED FAN*


AIRFLOW
(Cfm)
14,000
16,000
18,000
20,000
22,000
24,000
26,000
28,000
30,000

AIRFLOW
(Cfm)
14,000
16,000
18,000
20,000
22,000
24,000
26,000
28,000
30,000

AIRFLOW
(Cfm)
14,000
16,000
18,000
20,000
22,000
24,000
26,000
28,000
30,000

0.2
Rpm
211
232
253
275
298
320
343
367
390

Bhp
2.35
3.27
4.42
5.83
7.53
9.55
11.91
14.65
17.78

0.4
Rpm
243
261
281
301
321
342
364
386
408

1.8
Rpm
416
423
432
443
455
470
485
501
518

Bhp
9.12
10.62
12.36
14.38
16.70
19.38
22.43
25.89
29.76

Bhp
3.06
4.06
5.31
6.82
8.62
10.75
13.22
16.06
19.31

2.0
Rpm
437
442
450
460
472
486
500
516
533

Bhp
10.10
11.68
13.50
15.58
17.98
20.72
23.83
27.36
31.32

AVAILABLE EXTERNAL STATIC PRESSURE (in. wg)


0.6
0.8
1.0
1.2
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
272
3.80
299
4.59
325
5.43
349
6.30
288
4.88
313
5.74
337
6.65
360
7.59
305
6.21
329
7.14
351
8.11
372
912
324
7.81
346
8.82
366
9.86
386
10.94
343
9.70
364
10.80
383
11.92
402
13.07
363
11.93
383
13.11
401
14.31
419
15.54
384
14.50
402
15.78
420
17.07
437
18.37
405
17.45
422
18.83
439
20.20
455
21.59
426
20.80
443
22.28
459
23.75
474
25.24

Rpm
372
381
393
406
420
436
453
471
489

AVAILABLE EXTERNAL STATIC PRESSURE (in. wg)


2.2
2.4
2.6
2.8
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
457
11.10
476
12.13
495
13.17
513
14.22
462
12.77
480
13.88
498
15.00
516
16.15
469
14.66
486
15.84
504
17.05
521
18.27
478
16.82
495
18.07
511
19.35
527
20.65
489
19.28
505
20.60
521
21.96
536
23.33
501
22.08
517
23.48
532
24.89
547
26.34
515
25.27
530
26.73
544
28.22
559
29.72
530
28.86
544
30.38
558
31.94
572
33.51
546
32.89
560
34.48
573
36.10
586
37.74

Rpm
531
533
537
543
551
561
573
585
599

1.4
Bhp
7.21
8.57
10.17
12.05
14.25
16.79
19.70
23.00
26.73

1.6
Rpm
395
402
413
425
438
453
469
486
504

3.0
Bhp
15.29
17.31
19.53
21.98
24.72
27.80
31.26
35.11
39.41

Bhp
8.15
9.58
11.25
13.20
15.46
18.07
21.05
24.43
28.24

3.2
Rpm
548
550
553
559
566
576
586
599
612

Bhp
16.38
18.48
20.78
23.32
26.14
29.29
32.81
36.74
41.11

AVAILABLE EXTERNAL STATIC PRESSURE (in. wg)


3.4
3.6
3.8
4.0
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
564
17.47
581
18.58
596
19.71
612
20.84
566
19.68
582
20.88
597
22.10
613
23.33
569
22.06
585
23.36
600
24.66
615
25.99
574
24.68
589
26.06
604
27.45
618
28.85
581
27.57
596
29.04
610
30.51
624
31.99
590
30.80
604
32.33
617
33.88
631
35.44
600
34.39
613
35.99
627
37.61
640
39.24
612
38.38
624
40.05
637
41.74
650
43.44
624
42.81
637
44.54
649
46.29
661
48.06

LEGEND
48/50P3,P5 units only.
Bhp Brake Horsepower
*If calculating static pressure for a 48 Series unit, be sure to add gas
heat pressure drop from Component Pressure Drop table.
NOTES:
1. Fan performance is based on wet coils and clean 2-in. filters.
2. For return fan and high-capacity power exhaust units, add component pressure drop for economizer. Do not add component pressure
drop for power exhaust.

3. See Component Pressure Drop data table before using Fan Performance tables.
4. Conversion Bhp to kW:
Kilowatts =

Bhp x .746
Motor efficiency

See Physical Data table for motor efficiency.

117

Performance data (cont)


FAN PERFORMANCE 48/50P2,P3,P4,P5075 UNITS WITH AIRFOIL FAN*
AIRFLOW
(Cfm)
15,000
16,000
18,000
20,000
22,000
24,000
26,000
28,000
30,000

AIRFLOW
(Cfm)
15,000
16,000
18,000
20,000
22,000
24,000
26,000
28,000
30,000

AIRFLOW
(Cfm)
15,000
16,000
18,000
20,000
22,000
24,000
26,000
28,000
30,000

0.30
Rpm
Bhp
620
3.02
655
3.52
725
4.68
795
6.08
867
7.75
939
9.71
1012 11.99
1084 14.61
1157 17.60

0.60
Rpm
Bhp
671
3.91
703
4.45
769
5.71
836
7.22
904
9.00
974 11.07
1044 13.46
1115 16.18
1186 19.28

AVAILABLE EXTERNAL STATIC PRESSURE (in. wg)


0.90
1.20
1.50
1.80
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
720
4.83
767
5.80
813
6.81
858
7.87
749
5.41
794
6.42
838
7.47
881
8.56
810
6.76
851
7.84
891
8.96
930 10.12
874
8.36
911
9.52
947 10.71
983 11.94
940 10.24
974 11.49 1008 12.76 1041 14.06
1007 12.41 1039 13.75 1070 15.11 1101 16.49
1075 14.90 1105 16.34 1134 17.79 1163 19.25
1144 17.73 1172 19.28 1200 20.82 1227 22.37
1214 20.93 1240 22.57 1267 24.22 1292 25.86

2.10
Rpm
Bhp
902
8.97
922
9.69
968 11.32
1019 13.20
1073 15.39
1131 17.90
1191 20.74
1253 23.94
1317 27.51

2.40
Rpm
Bhp
944 10.10
963 10.86
1006 12.55
1054 14.51
1105 16.76
1161 19.33
1219 22.25
1280 25.52
1342 29.18

2.70
Rpm
Bhp
984 11.25
1003 12.06
1043 13.82
1088 15.84
1137 18.15
1191 20.79
1247 23.78
1306 27.12
1367 30.86

3.00
Rpm
Bhp
1023 12.42
1041 13.27
1079 15.12
1122 17.21
1169 19.58
1220 22.28
1274 25.33
1332 28.75
1391 32.57

AVAILABLE EXTERNAL STATIC PRESSURE (in. wg)


3.30
3.60
3.90
4.20
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
1061 13.60 1097 14.80 1131 16.00 1165 17.22
1078 14.51 1113 15.76 1148 17.02 1181 18.29
1114 16.44 1149 17.79 1182 19.15 1215 20.52
1155 18.60 1188 20.02 1220 21.47 1251 22.93
1200 21.05 1231 22.54 1261 24.05 1291 25.59
1249 23.81 1278 25.36 1307 26.94 1335 28.55
1302 26.92 1329 28.53 1356 30.18 1382 31.85
1357 30.41 1383 32.08 1408 33.79 1433 35.52
1415 34.29 1439 36.03 1463 37.81 1487 39.60

4.50
Rpm
Bhp
1198 18.44
1214 19.56
1247 21.91
1282 24.42
1321 27.15
1363 30.18
1409 33.54
1458 37.28
1510 41.42

4.80
Rpm
Bhp
1229 19.67
1245 20.85
1278 23.31
1312 25.91
1350 28.74
1390 31.83
1435 35.26
1483 39.05
1534 43.25

AVAILABLE EXTERNAL STATIC PRESSURE (in. wg)


5.10
5.40
5.70
6.00
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
1260 20.91 1290 22.15 1319 23.41 1347 24.66
1276 22.15 1305 23.45 1334 24.76 1362 26.08
1308 24.71 1337 26.13 1366 27.56 1394 28.99
1342 27.42 1370 28.95 1399 30.48 1426 32.02
1378 30.33 1406 31.95 1434 33.57 1461 35.21
1418 33.51 1445 35.20 1471 36.91 1497 38.64
1461 37.00 1487 38.76 1512 40.54 1537 42.35
1507 40.86 1532 42.69 1556 44.54 1580 46.40
1557 45.12 1580 47.01 1603 48.92 1626 50.85

LEGEND
48/50P3,P5 units only.
Bhp Brake Horsepower
*If calculating static pressure for a 48 Series unit, be sure to add gas
heat pressure drop from Component Pressure Drop table.
NOTES:
1. Fan performance is based on wet coils and clean 2-in. filters.
2. For return fan high-capacity power exhaust units, add component
pressure drop for economizer. Do not add component pressure drop
for power exhaust.

118

3. See Component Pressure Drop data table before using Fan Performance tables.
4. Conversion Bhp to kW:
Kilowatts =

Bhp x .746
Motor efficiency

See Physical Data table for motor efficiency.

FAN PERFORMANCE 48/50P2,P3,P4,P5090 UNITS WITH FORWARD-CURVED FAN*


AIRFLOW
(Cfm)
16,000
18,000
20,000
22,000
24,000
26,000
28,000
30,000
32,000
34,000

AIRFLOW
(Cfm)
16,000
18,000
20,000
22,000
24,000
26,000
28,000
30,000
32,000
34,000

AIRFLOW
(Cfm)
16,000
18,000
20,000
22,000
24,000
26,000
28,000
30,000
32,000
34,000

0.2
Rpm
232
253
275
298
320
343
367
390
414
437

Bhp
3.27
4.42
5.83
7.53
9.55
11.91
14.65
17.78
21.36
25.39

0.4
Rpm
261
281
301
321
342
364
386
408
431
454

1.8
Rpm
423
432
443
455
470
485
501
518
536
555

Bhp
10.62
12.36
14.38
16.70
19.38
22.43
25.89
29.76
34.11
38.92

Bhp
4.06
5.31
6.82
8.62
10.75
13.22
16.06
19.31
22.99
27.13

2.0
Rpm
442
450
460
472
486
500
516
533
550
568

Bhp
11.68
13.50
15.58
17.98
20.72
23.83
27.36
31.32
35.73
40.63

AVAILABLE EXTERNAL STATIC PRESSURE (in. wg)


0.6
0.8
1.0
1.2
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
288
4.88
313
5.74
337
6.65
360
7.59
305
6.21
329
7.14
351
8.11
372
9.12
324
7.81
346
8.82
366
9.86
386
10.94
343
9.70
364
10.80
383
11.92
402
13.07
363
11.93
383
13.11
401
14.31
419
15.54
384
14.50
402
15.78
420
17.07
437
18.37
405
17.45
422
18.83
439
20.20
455
21.59
426
20.80
443
22.28
459
23.75
474
25.24
448
24.59
464
26.17
479
27.75
494
29.32
470
28.84
485
30.53
500
32.20
514
33.87

Rpm
381
393
406
420
436
453
471
489
508
528

AVAILABLE EXTERNAL STATIC PRESSURE (in. wg)


2.2
2.4
2.6
2.8
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
462
12.77
480
13.88
498
15.00
516
16.15
469
14.66
486
15.84
504
17.05
521
18.27
478
16.82
495
18.07
511
19.35
527
20.65
489
19.28
505
20.60
521
21.96
536
23.33
501
22.08
517
23.48
532
24.89
547
26.34
515
25.27
530
26.73
544
28.22
559
29.72
530
28.86
544
30.38
558
31.94
572
33.51
546
32.89
560
34.48
573
36.10
586
37.74
563
37.38
576
39.04
589
40.73
601
42.45
581
42.36
593
44.10
605
45.87
618
47.64

Rpm
533
537
543
551
561
573
585
599
614
630

1.4
Bhp
8.57
10.17
12.05
14.25
16.79
19.70
23.00
26.73
30.90
35.55

1.6
Rpm
402
413
425
438
453
469
486
504
523
542

3.0
Bhp
17.31
19.53
21.98
24.72
27.80
31.26
35.11
39.41
44.18
49.45

Bhp
9.58
11.25
13.20
15.46
18.07
21.05
24.43
28.24
32.49
37.23

3.2
Rpm
550
553
559
566
576
586
599
612
626
641

Bhp
18.48
20.78
23.32
26.14
29.29
32.81
36.74
41.11
45.94
51.27

AVAILABLE EXTERNAL STATIC PRESSURE (in. wg)


3.4
3.6
3.8
4.0
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
566
19.68
582
20.88
597
22.10
613
23.33
569
22.06
585
23.36
600
24.66
615
25.99
574
24.68
589
26.06
604
27.45
618
28.85
581
27.57
596
29.04
610
30.51
624
31.99
590
30.80
604
32.33
617
33.88
631
35.44
600
34.39
613
35.99
627
37.61
640
39.24
612
38.38
624
40.05
637
41.74
650
43.44
624
42.81
637
44.54
649
46.29
661
48.06
638
47.72
650
49.51
662
51.33
674
53.17
653
53.12
665
54.98
676
56.87

LEGEND
48/50P3,P5 units only.
Bhp Brake Horsepower
*If calculating static pressure for a 48 Series unit, be sure to add gas
heat pressure drop from Component Pressure Drop table.
NOTES:
1. Fan performance is based on wet coils and clean 2-in. filters.
2. For return fan and high-capacity power exhaust units, add component pressure drop for economizer. Do not add component pressure
drop for power exhaust.

3. See Component Pressure Drop data table before using Fan Performance tables.
4. Conversion Bhp to kW:
Kilowatts =

Bhp x .746
Motor efficiency

See Physical Data table for motor efficiency.

119

Performance data (cont)


FAN PERFORMANCE 48/50P2,P3,P4,P5090 UNITS WITH AIRFOIL FAN*
AIRFLOW
(Cfm)
17,000
18,000
20,000
22,000
24,000
26,000
28,000
30,000
32,000
34,000

AIRFLOW
(Cfm)
17,000
18,000
20,000
22,000
24,000
26,000
28,000
30,000
32,000
34,000

AIRFLOW
(Cfm)
17,000
18,000
20,000
22,000
24,000
26,000
28,000
30,000
32,000
34,000

0.30
Rpm
Bhp
690
4.07
725
4.68
795
6.08
867
7.75
939
9.71
1012 11.99
1084 14.61
1157 17.60
1231 20.97
1304 24.75

0.60
Rpm
Bhp
735
5.05
769
5.71
836
7.22
904
9.00
974 11.07
1044 13.46
1115 16.18
1186 19.28
1258 22.76
1330 26.65

AVAILABLE EXTERNAL STATIC PRESSURE (in. wg)


0.90
1.20
1.50
1.80
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
779
6.06
822
7.10
863
8.18
904
9.31
810
6.76
851
7.84
891
8.96
930 10.12
874
8.36
911
9.52
947 10.71
983 11.94
940 10.24
974 11.49 1008 12.76 1041 14.06
1007 12.41 1039 13.75 1070 15.11 1101 16.49
1075 14.90 1105 16.34 1134 17.79 1163 19.25
1144 17.73 1172 19.28 1200 20.82 1227 22.37
1214 20.93 1240 22.57 1267 24.22 1292 25.86
1284 24.52 1309 26.26 1334 28.00 1358 29.74
1355 28.52 1379 30.36 1403 32.20 1426 34.04

2.10
Rpm
Bhp
945 10.47
968 11.32
1019 13.20
1073 15.39
1131 17.90
1191 20.74
1253 23.94
1317 27.51
1382 31.48
1448 35.87

2.40
Rpm
Bhp
984 11.68
1006 12.55
1054 14.51
1105 16.76
1161 19.33
1219 22.25
1280 25.52
1342 29.18
1406 33.23
1471 37.71

2.70
Rpm
Bhp
1022 12.91
1043 13.82
1088 15.84
1137 18.15
1191 20.79
1247 23.78
1306 27.12
1367 30.86
1429 35.00
1493 39.57

3.00
Rpm
Bhp
1059 14.17
1079 15.12
1122 17.21
1169 19.58
1220 22.28
1274 25.33
1332 28.75
1391 32.57
1452 36.78
1515 41.43

AVAILABLE EXTERNAL STATIC PRESSURE (in. wg)


3.30
3.60
3.90
4.20
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
1096 15.45 1131 16.75 1165 18.06 1198 19.38
1114 16.44 1149 17.79 1182 19.15 1215 20.52
1155 18.60 1188 20.02 1220 21.47 1251 22.93
1200 21.05 1231 22.54 1261 24.05 1291 25.59
1249 23.81 1278 25.36 1307 26.94 1335 28.55
1302 26.92 1329 28.53 1356 30.18 1382 31.85
1357 30.41 1383 32.08 1408 33.79 1433 35.52
1415 34.29 1439 36.03 1463 37.81 1487 39.60
1475 38.58 1498 40.40 1520 42.24 1543 44.10
1537 43.31 1558 45.20 1580 47.11 1601 49.05

4.50
Rpm
Bhp
1230 20.72
1247 21.91
1282 24.42
1321 27.15
1363 30.18
1409 33.54
1458 37.28
1510 41.42
1565 45.98
1622 50.99

4.80
Rpm
Bhp
1261 22.06
1278 23.31
1312 25.91
1350 28.74
1390 31.83
1435 35.26
1483 39.05
1534 43.25
1587 47.88
1643 52.96

AVAILABLE EXTERNAL STATIC PRESSURE (in. wg)


5.10
5.40
5.70
6.00
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
1291 23.42 1321 24.77 1350 26.14 1378 27.52
1308 24.71 1337 26.13 1366 27.56 1394 28.99
1342 27.42 1370 28.95 1399 30.48 1426 32.02
1378 30.33 1406 31.95 1434 33.57 1461 35.21
1418 33.51 1445 35.20 1471 36.91 1497 38.64
1461 37.00 1487 38.76 1512 40.54 1537 42.35
1507 40.86 1532 42.69 1556 44.54 1580 46.40
1557 45.12 1580 47.01 1603 48.92 1626 50.85
1609 49.81 1631 51.76 1653 53.72 1675 55.72
1664 54.95 1685 56.96 1706 58.99 1727 61.04

LEGEND
48/50P3,P5 units only.
Bhp Brake Horsepower
*If calculating static pressure for a 48 Series unit, be sure to add gas
heat pressure drop from Component Pressure Drop table.
NOTES:
1. Fan performance is based on wet coils and clean 2-in. filters.
2. For return fan and high-capacity power exhaust units, add component pressure drop for economizer. Do not add component pressure
drop for power exhaust.

120

3. See Component Pressure Drop data table before using Fan Performance tables.
4. Conversion Bhp to kW:
Kilowatts =

Bhp x .746
Motor efficiency

See Physical Data table for motor efficiency.

FAN PERFORMANCE 48/50P2,P3,P4,P5100 UNITS WITH FORWARD-CURVED FAN*


AIRFLOW
(Cfm)
20,000
22,000
24,000
26,000
28,000
30,000
32,000
34,000
36,000
38,000
40,000

AIRFLOW
(Cfm)
20,000
22,000
24,000
26,000
28,000
30,000
32,000
34,000
36,000
38,000
40,000

AIRFLOW
(Cfm)
20,000
22,000
24,000
26,000
28,000
30,000
32,000
34,000
36,000
38,000
40,000

0.2
Rpm
275
298
320
343
367
390
414
437
461
485
509

Bhp
5.83
7.53
9.55
11.91
14.65
17.78
21.36
25.39
29.92
34.96
40.54

0.4
Rpm
301
321
342
364
386
408
431
454
477
500
523

1.8
Rpm
443
455
470
485
501
518
536
555
574
593
613

Bhp
14.38
16.70
19.38
22.43
25.89
29.76
34.11
38.92
44.25
50.10
56.52

Bhp
6.82
8.62
10.75
13.22
16.06
19.31
22.99
27.13
31.77
36.91
42.61

2.0
Rpm
460
472
486
500
516
533
550
568
586
605
625

Bhp
15.58
17.98
20.72
23.83
27.36
31.32
35.73
40.63
46.03
51.98
58.49

AVAILABLE EXTERNAL STATIC PRESSURE (in. wg)


0.6
0.8
1.0
1.2
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
324
7.81
346
8.82
366
9.86
386
10.94
343
9.70
364
10.80
383
11.92
402
13.07
363
11.93
383
13.11
401
14.31
419
15.54
384
14.50
402
15.78
420
17.07
437
18.37
405
17.45
422
18.83
439
20.20
455
21.59
426
20.80
443
22.28
459
23.75
474
25.24
448
24.59
464
26.17
479
27.75
494
29.32
470
28.84
485
30.53
500
32.20
514
33.87
492
33.58
506
35.38
521
37.16
534
38.93
514
38.85
528
40.74
542
42.63
555
44.50
537
44.65
550
46.66
563
48.64
576
50.62

Rpm
406
420
436
453
471
489
508
528
548
568
589

AVAILABLE EXTERNAL STATIC PRESSURE (in. wg)


2.2
2.4
2.6
2.8
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
478
16.82
495
18.07
511
19.35
527
20.65
489
19.28
505
20.60
521
21.96
536
23.33
501
22.08
517
23.48
532
24.89
547
26.34
515
25.27
530
26.73
544
28.22
559
29.72
530
28.86
544
30.38
558
31.94
572
33.51
546
32.89
560
34.48
573
36.10
586
37.74
563
37.38
576
39.04
589
40.73
601
42.45
581
42.36
593
44.10
605
45.87
618
47.64
599
47.85
611
49.67
623
51.51
634
53.37
617
53.87
629
55.77
640
57.71
652
59.63
636
60.48
648
62.46
659
64.47

Rpm
543
551
561
573
585
599
614
630
646
663

1.4
Bhp
12.05
14.25
16.79
19.70
23.00
26.73
30.90
35.55
40.69
46.36
52.59

1.6
Rpm
425
438
453
469
486
504
523
542
561
581
601

3.0
Bhp
21.98
24.72
27.80
31.26
35.11
39.41
44.18
49.45
55.25
61.59

Bhp
13.20
15.46
18.07
21.05
24.43
28.24
32.49
37.23
42.47
48.23
54.56

3.2
Rpm
559
566
576
586
599
612
626
641
657
674

Bhp
23.32
26.14
29.29
32.81
36.74
41.11
45.94
51.27
57.14
63.54

AVAILABLE EXTERNAL STATIC PRESSURE (in. wg)


3.4
3.6
3.8
4.0
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
574
24.68
589
26.06
604
27.45
618
28.86
581
27.57
596
29.04
610
30.51
624
31.99
590
30.80
604
32.33
617
33.88
631
35.44
600
34.39
613
35.99
627
37.61
640
39.24
612
38.38
624
40.05
637
41.74
650
43.44
624
42.81
637
44.54
649
46.29
661
48.06
638
47.72
650
49.51
662
51.33
674
53.17
653
53.12
665
54.98
676
56.87

669
59.06
680
60.98

LEGEND
48/50P3,P5 units only.
Bhp Brake Horsepower
*If calculating static pressure for a 48 Series unit, be sure to add gas
heat pressure drop from Component Pressure Drop table.
NOTES:
1. Fan performance is based on wet coils and clean 2-in. filters.
2. For return fan and high-capacity power exhaust units, add component pressure drop for economizer. Do not add component pressure
drop for power exhaust.

3. See Component Pressure Drop data table before using Fan Performance tables.
4. Conversion Bhp to kW:
Kilowatts =

Bhp x .746
Motor efficiency

See Physical Data table for motor efficiency.

121

Performance data (cont)


FAN PERFORMANCE 48/50P2,P3,P4,P5100 UNITS WITH AIRFOIL FAN*
AIRFLOW
(Cfm)
20,000
22,000
24,000
26,000
28,000
30,000
32,000
34,000
36,000
38,000
40,000

AIRFLOW
(Cfm)
20,000
22,000
24,000
26,000
28,000
30,000
32,000
34,000
36,000
38,000
40,000

AIRFLOW
(Cfm)
20,000
22,000
24,000
26,000
28,000
30,000
32,000
34,000
36,000
38,000
40,000

0.30
Rpm
Bhp
795
6.08
867
7.75
939
9.71
1012 11.99
1084 14.61
1157 17.60
1231 20.97
1304 24.75
1378 28.97
1452 33.65
1526 38.81

0.60
Rpm
Bhp
836
7.22
904
9.00
974 11.07
1044 13.46
1115 16.18
1186 19.28
1258 22.76
1330 26.65
1402 30.97
1475 35.75
1548 41.02

AVAILABLE EXTERNAL STATIC PRESSURE (in. wg)


0.90
1.20
1.50
1.80
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
874
8.36
911
9.52
947 10.71
983 11.94
940 10.24
974 11.49 1008 12.76 1041 14.06
1007 12.41 1039 13.75 1070 15.11 1101 16.49
1075 14.90 1105 16.34 1134 17.79 1163 19.25
1144 17.73 1172 19.28 1200 20.82 1227 22.37
1214 20.93 1240 22.57 1267 24.22 1292 25.86
1284 24.52 1309 26.26 1334 28.00 1358 29.74
1355 28.52 1379 30.36 1403 32.20 1426 34.04
1426 32.94 1449 34.89 1472 36.84 1494 38.76
1498 37.82 1520 39.89 1541 41.92 1562 43.95
1570 43.20 1591 45.35 1611 47.49 1632 49.63

2.10
Rpm
Bhp
1019 13.20
1073 15.39
1131 17.90
1191 20.74
1253 23.94
1317 27.51
1382 31.48
1448 35.87
1515 40.70
1583 45.98
1652 51.76

2.40
Rpm
Bhp
1054 14.51
1105 16.76
1161 19.33
1219 22.25
1280 25.52
1342 29.18
1406 33.23
1471 37.71
1537 42.64
1604 48.01
1671 53.88

2.70
Rpm
Bhp
1088 15.84
1137 18.15
1191 20.79
1247 23.78
1306 27.12
1367 30.86
1429 35.00
1493 39.57
1558 44.57
1624 50.05
1691 56.01

3.00
Rpm
Bhp
1122 17.21
1169 19.58
1220 22.28
1274 25.33
1332 28.75
1391 32.57
1452 36.78
1515 41.43
1579 46.53
1644 52.08
1710 58.13

AVAILABLE EXTERNAL STATIC PRESSURE (in. wg)


3.30
3.60
3.90
4.20
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
1155 18.60 1188 20.02 1220 21.47 1251 22.93
1200 21.05 1231 22.54 1261 24.05 1291 25.59
1249 23.81 1278 25.36 1307 26.94 1335 28.55
1302 26.92 1329 28.53 1356 30.18 1382 31.85
1357 30.41 1383 32.08 1408 33.79 1433 35.52
1415 34.29 1439 36.03 1463 37.81 1487 39.60
1475 38.58 1498 40.40 1520 42.24 1543 44.10
1537 43.31 1558 45.20 1580 47.11 1601 49.05
1600 48.48 1620 50.46 1641 52.44 1661 54.44
1664 54.13 1684 56.19 1703 58.25 1722 60.33
1729 60.26 1748 62.41 1767 64.55 1785 66.71

4.50
Rpm
Bhp
1282 24.42
1321 27.15
1363 30.18
1409 33.54
1458 37.28
1510 41.42
1565 45.98
1622 50.99
1681 56.46
1742 62.43

4.80
Rpm
Bhp
1312 25.91
1350 28.74
1390 31.83
1435 35.26
1483 39.05
1534 43.25
1587 47.88
1643 52.96
1701 58.50
1761 64.54

AVAILABLE EXTERNAL STATIC PRESSURE (in. wg)


5.10
5.40
5.70
6.00
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
1342 27.42 1370 28.95 1399 30.48 1426 32.02
1378 30.33 1406 31.95 1434 33.57 1461 35.21
1418 33.51 1445 35.20 1471 36.91 1497 38.64
1461 37.00 1487 38.76 1512 40.54 1537 42.35
1507 40.86 1532 42.69 1556 44.54 1580 46.40
1557 45.12 1580 47.01 1603 48.92 1626 50.85
1609 49.81 1631 51.76 1653 53.72 1675 55.72
1664 54.95 1685 56.96 1706 58.99 1727 61.04
1721 60.57 1741 62.64 1761 64.73 1781 66.85
1780 66.66

LEGEND
48/50P3,P5 units only.
Bhp Brake Horsepower
*If calculating static pressure for a 48 Series unit, be sure to add gas
heat pressure drop from Component Pressure Drop table.
NOTES:
1. Fan performance is based on wet coils and clean 2-in. filters.
2. For return fan and high-capacity power exhaust units, add component pressure drop for economizer. Do not add component pressure
drop for power exhaust.

122

3. See Component Pressure Drop data table before using Fan Performance tables.
4. Conversion Bhp to kW:
Kilowatts =

Bhp x .746
Motor efficiency

See Physical Data table for motor efficiency.

FAN PERFORMANCE STANDARD CAPACITY POWER EXHAUST


48/50P2,P3,P4,P5030-050 UNITS
AIRFLOW
(Cfm)
6,000
8,000
10,000
12,000
14,000
16,000
18,000
20,000

0.20
Rpm Bhp
380
0.95
440
1.69
504
2.73
575
4.17
650
6.09
729
8.57
809 11.57
891 15.47

0.40
Rpm Bhp
468
1.47
523
2.40
582
3.68
643
5.33
708
7.42
778 10.02
851 13.19
927 17.22

0.60
Rpm Bhp
543
2.01
591
3.08
647
4.55
705
6.42
766
8.73
829 11.43
896 14.90
967 19.08

AVAILABLE EXTERNAL STATIC PRESSURE (in. wg)


0.80
1.00
1.20
1.40
1.60
Rpm Bhp Rpm Bhp Rpm Bhp Rpm Bhp Rpm Bhp
612
2.60 676
3.24 738
3.92 796
4.64 852
5.39
651
3.77 706
4.49 759
5.23 810
6.01 859
6.82
703
5.38 754
6.22 802
7.06 847
7.92 891
8.80
760
7.45 809
8.44 854
9.41 896 10.38 937 11.27
819
9.97 867 11.05 910 12.22 951 13.38 990 14.53
879 12.93 926 14.37 969 15.76

942 16.61 987 18.29

1.80
Rpm Bhp
905
6.17
907
7.66
933
9.70
976 12.29

2.00
Rpm Bhp
956
6.98
953
8.53
975 10.52

1.8
Rpm Bhp
808
5.86
822
7.30
845
9.03
878 11.16
918 13.81

2.0
Rpm Bhp
850
6.47
861
8.00
881
9.80
910 11.98

48/50P2,P3,P4,P5055-100 UNITS
AIRFLOW
(Cfm)
10,000
12,000
14,000
16,000
18,000
20,000
22,000
24,000

0.2
Rpm Bhp
416
1.65
480
2.67
546
4.09
613
5.95
682
8.32
752 11.27
821 14.86
892 19.16

0.4
Rpm Bhp
469
2.03
524
3.09
584
4.55
647
6.46
712
8.88
779 11.89
846 15.53
915 19.89

0.6
Rpm Bhp
522
2.47
568
3.56
621
5.05
680
7.00
741
9.47
805 12.53
871 16.23

AVAILABLE EXTERNAL STATIC PRESSURE (in. wg)


0.8
1.0
1.2
1.4
1.6
Rpm Bhp Rpm Bhp Rpm Bhp Rpm Bhp Rpm Bhp
574
2.97 624
3.51 673
4.08 720
4.66 765
5.26
612
4.09 656
4.67 699
5.29 741
5.94 782
6.61
659
5.61 697
6.21 735
6.87 772
7.56 809
8.28
713
7.59 746
8.22 779
8.90 812
9.62 845 10.37
771 10.10 800 10.76 830 11.47 859 12.21 889 13.00
832 13.19 858 13.90 885 14.63 911 15.41

895 16.94 919 17.69

Bhp Brake Horsepower

FAN PERFORMANCE OPTIONAL RETURN/EXHAUST FAN (48/50P2,P3,P4,P5075-100 Units)


AIRFLOW
(Cfm)
14,000
16,000
18,000
20,000
22,000
24,000
26,000
28,000
30,000
32,000
34,000
36,000
38,000
40,000

AIRFLOW
(Cfm)
14,000
16,000
18,000
20,000
22,000
24,000
26,000
28,000
30,000
32,000
34,000
36,000
38,000
40,000

0.2
Rpm Bhp
594 3.61
619 4.09
687 5.57
756 7.37
825 9.50
895 11.94
965 14.94
1035 18.43
1105 22.42
1176 26.96
1246 32.09
1317 37.83
1388 44.22

0.4
Rpm Bhp
594 3.61
652 4.76
718 6.35
786 8.25
853 10.50
922 13.08
990 16.21
1059 19.81
1128 23.93
1198 28.59
1267 33.83
1337 39.69
1407 46.21

0.6
Rpm Bhp
617 4.02
681 5.40
746 7.07
812 9.06
878 11.31
945 14.12
1013 17.36
1081 21.09
1149 25.33
1218 30.11
1287 35.47
1356 41.46

AVAILABLE EXTERNAL STATIC PRESSURE (in. wg)


0.8
1.0
1.2
1.4
1.6
Rpm Bhp Rpm Bhp Rpm Bhp Rpm Bhp Rpm Bhp
646 4.58 674 5.16 700 5.75 725 6.36 749 6.99
708 6.02 733 6.65 757 7.29 781 7.94 803 8.61
771 7.76 795 8.45 817 9.14 839 9.85 860 10.56
836 9.84 858 10.59 879 11.25 900 12.03 920 12.82
901 12.20 923 13.06 943 13.90 962 14.75 981 15.60
967 15.10 988 16.05 1007 16.99 1026 17.91 1044 18.83
1034 18.46 1054 19.51 1073 20.53 1091 21.54 1108 22.54
1101 22.29 1120 23.45 1138 24.57 1156 25.67 1172 26.76
1169 26.65 1187 27.92 1205 29.14 1222 30.34 1238 31.51
1237 31.55 1255 32.93 1272 34.26 1288 35.56 1304 36.83
1305 37.03 1322 38.53 1339 39.97 1355 41.38 1370 42.75
1374 43.14 1391 44.75 1407 46.31

1.8
Rpm Bhp
772 7.62
825 9.30
881 11.20
939 13.62
1000 16.46
1061 19.76
1125 23.54
1189 27.83
1253 32.67
1319 38.08
1385 44.10

2.0
Rpm Bhp
795 8.25
847 9.99
901 11.96
958 14.43
1018 17.33
1079 20.69
1141 24.54
1204 28.91
1269 33.83
1333 39.32
1399 45.43

2.2
Rpm Bhp
816 8.89
867 10.59
921 12.74
977 15.25
1035 18.21
1095 21.62
1157 25.54
1220 29.98
1283 34.98
1348 40.55
1413 46.75

2.4
Rpm Bhp
836 9.52
887 11.31
940 13.52
995 16.10
1052 19.10
1112 22.58
1173 26.55
1235 31.06
1298 36.13
1362 41.78

2.6
Rpm Bhp
856 10.15
907 12.05
959 14.33
1013 16.96
1069 20.01
1128 23.54
1188 27.57
1249 32.14
1312 37.28
1375 43.00

AVAILABLE EXTERNAL STATIC PRESSURE (in. wg)


2.8
3.0
3.2
3.4
3.6
Rpm Bhp Rpm Bhp Rpm Bhp Rpm Bhp Rpm Bhp
874 10.67 892 11.31 910 11.94 926 12.57 942 13.19
926 12.78 944 13.52 961 14.25 978 14.98 995 15.71
977 15.13 995 15.95 1012 16.77 1029 17.59 1046 18.42
1031 17.82 1048 18.70 1065 19.59 1081 20.49 1097 21.39
1086 20.93 1103 21.86 1119 22.81 1135 23.76 1150 24.73
1144 24.51 1159 25.49 1175 26.49 1190 27.50 1205 28.52
1203 28.59 1218 29.64 1233 30.68 1247 31.74 1262 32.81
1264 33.23 1278 34.32 1292 35.42 1306 36.53 1320 37.65
1326 38.42 1340 39.58 1353 40.74 1367 41.92 1380 43.09
1389 44.22 1402 45.45 1415 46.67

3.8
Rpm Bhp
958 13.80
1011 16.44
1062 19.24
1113 22.30
1166 25.71
1220 29.55
1276 33.89
1334 38.78
1393 44.27

4.0
Rpm Bhp
973 14.42
1026 17.16
1078 20.07
1129 23.21
1181 26.69
1234 30.58
1290 34.98
1347 39.93
1406 45.46

Bhp Brake Horsepower

123

Performance data (cont)


FAN PERFORMANCE OPTIONAL HIGH-CAPACITY POWER EXHAUST
(48/50P2,P3,P4,P5075-100)
AIRFLOW
(cfm)
14,000
16,000
18,000
20,000
22,000
24,000
26,000
28,000
30,000
32,000
34,000
36,000
38,000
40,000

AIRFLOW
(cfm)
14,000
16,000
18,000
20,000
22,000
24,000
26,000
28,000
30,000
32,000
34,000
36,000
38,000
40,000

AIRFLOW
(cfm)
14,000
16,000
18,000
20,000
22,000
24,000
26,000
28,000
30,000
32,000
34,000
36,000
38,000
40,000

AIRFLOW
(cfm)
14,000
16,000
18,000
20,000
22,000
24,000
26,000
28,000
30,000
32,000
34,000
36,000
38,000
40,000

Rpm
436
486
536
588
639
692
745
798
851
905
959
1013
1067
1121

Bhp
3.79
5.37
7.37
9.81
12.75
16.21
20.24
24.87
30.15
36.10
42.76
50.17
58.36
67.37

Bhp
5.48
7.12
9.14
11.57
14.46
17.86
21.82
26.37
31.55
37.41
43.98
51.30
59.40

Rpm
592
629
670
712
757
802
849
896
944
993
1042
1092
1142

Rpm
659
690
726
765
807
850
894
940
986
1033
1081
1129

AVAILABLE EXTERNAL STATIC PRESSURE (in. wg)


1.4
1.6
1.8
Bhp
Rpm
Bhp
Rpm
7.42
691
8.09
722
9.22
720
9.94
749
11.36
754
12.14
780
13.91
791
14.73
816
16.89
831
17.75
854
20.35
873
21.25
895
24.33
916
25.26
937
28.89
961
29.83
981
34.06
1006
35.01
1026
39.88
1053
40.84
1071
46.39
1100
47.35
1118
53.65
1147
54.59
1165

Bhp
8.77
10.68
12.93
15.57
18.63
22.16
26.21
30.81
36.00
41.84
48.36
55.60

Rpm
752
777
806
840
877
917
958
1001
1045
1090
1136

Rpm
811
832
858
888
922
959
998
1040
1082
1126
1170

AVAILABLE EXTERNAL STATIC PRESSURE (in. wg)


2.4
2.6
2.8
Bhp
Rpm
Bhp
Rpm
10.83
839
11.53
866
12.93
858
13.69
884
15.35
882
16.17
907
18.14
911
19.01
934
21.34
944
22.26
966
25.00
980
25.98
1000
29.16
1018
30.17
1037
33.86
1058
34.91
1077
39.14
1100
40.23
1118
45.05
1143
46.16
1160
51.61

Bhp
12.23
14.46
16.99
19.89
23.20
26.95
31.20
35.98
41.33
47.29

Rpm
892
910
931
957
987
1020
1057
1095
1135

Rpm
943
959
978
1001
1029
1060
1094
1131
1169

AVAILABLE EXTERNAL STATIC PRESSURE (in. wg)


3.4
3.6
3.8
Bhp
Rpm
Bhp
Rpm
14.34
967
15.05
990
16.77
983
17.55
1006
19.50
1001
20.34
1024
22.57
1023
23.47
1045
26.03
1050
26.99
1070
29.94
1080
30.94
1099
34.32
1113
35.37
1131
39.23
1148
40.33
1166
44.69

Bhp
15.75
18.33
21.19
24.38
27.96
31.96
36.44
41.44

Rpm
1013
1029
1046
1066
1090
1118
1149

1.2
Rpm
626
660
698
739
782
827
872
918
965
1013
1062
1111
1160

Bhp
6.76
8.50
10.60
13.10
16.05
19.48
23.44
27.99
33.15
38.98
45.50
52.77
60.81

2.2
Rpm
782
805
832
864
900
938
979
1020
1064
1108
1153

Bhp
10.14
12.18
14.53
17.27
20.43
24.04
28.17
32.83
38.07
43.95
50.49

3.2
Rpm
918
934
955
979
1008
1040
1075
1113
1152

LEGEND
Bhp Brake Horsepower

124

Rpm
480
526
574
622
671
722
772
824
875
928
980
1033
1086
1139

AVAILABLE EXTERNAL STATIC PRESSURE (in. wg)


0.4
0.6
0.8
Bhp
Rpm
Bhp
Rpm
4.28
520
4.86
557
5.86
563
6.47
597
7.84
608
8.45
639
10.26
654
10.87
684
13.16
701
13.76
730
16.59
750
17.16
777
20.58
799
21.13
824
25.18
849
25.70
873
30.43
899
30.91
922
36.35
950
36.80
972
42.98
1001
43.40
1022
50.37
1053
50.75
1072
58.53
1105
58.89
1124
67.52
1157
67.84

0.2

Bhp
13.64
16.00
18.66
21.67
25.08
28.93
33.27
38.14
43.56

1.0
Bhp
6.11
7.80
9.86
12.32
15.23
18.65
22.60
27.14
32.31
38.14
44.69
51.98
60.05

2.0
Bhp
9.45
11.42
13.73
16.41
19.52
23.10
27.17
31.81
37.02
42.88
49.41

3.0
Bhp
12.93
15.23
17.82
20.78
24.14
27.94
32.23
37.05
42.44

4.0
Bhp
16.46
19.11
22.04
25.29
28.92
32.98
37.51

COMPONENT PRESSURE DROPS (in. wg)


SIZE 030-050 UNITS
COMPONENT
ECONOMIZER
FILTERS
30% Pleated (2-in.)
Bags with Prefilters
4-in. Filters (field convert)
Cartridge Filters
POWER EXHAUST (48/50P2, P3 Units)
POWER EXHAUST (48/50P4, P5 Units)
LOW GAS HEAT (48P2,P3 Units)
HIGH GAS HEAT (48P2,P3 Units)
LOW GAS HEAT (48P4,P5 Units)
HIGH GAS HEAT (48P4,P5 Units)
ELECTRIC HEAT*
36 kW
72 kW
108 kW
HYDRONIC COIL
HIGH-CAPACITY COIL (030)
HIGH-CAPACITY COIL (040)
HIGH-CAPACITY COIL (050)
Humidi-MiZer SYSTEM

AIRFLOW (cfm)
12,000
14,000
0.16
0.20

6,000
0.06

8,000
0.09

10,000
0.12

0.00
0.22
0.02
0.21
0.02
0.09
0.09

0.24
0.08

0.00
0.31
0.05
0.29
0.03
0.15
0.18
0.21
0.42
0.22

0.00
0.41
0.06
0.37
0.05
0.22
0.31
0.38
0.71
0.46

0.00
0.52
0.08
0.46
0.08
0.30
0.48
0.60
1.09
0.79

0.07
0.041
0.062
0.045
0.05

0.03
0.06
0.12
0.11
0.055
0.100
0.067
0.07

0.07
0.11
0.18
0.16
0.070
0.148
0.099
0.09

0.12
0.18
0.26
0.22
0.087
0.206
0.142
0.11

16,000
0.25

18,000
0.30

20,000
0.35

0.01
0.64
0.09
0.55
0.11
0.41
0.68
0.86
1.58
1.20

0.01
0.76
0.11
0.65
0.15
0.53
0.92
1.17
2.17
1.71

0.02
0.89
0.13
0.75
0.20
0.66
1.19
1.53
2.86
2.31

0.03
1.03
0.15
0.86
0.25
0.81
1.50
1.93
3.66
3.01

0.18
0.26
0.36
0.29
0.104
0.274
0.195
0.14

0.26
0.36
0.47
0.37
0.123
0.351
0.259
0.17

0.35
0.47
0.59
0.46
0.143
0.436
0.333
0.20

0.46
0.60
0.73
0.55
0.165
0.536
0.417
0.23

SIZE 055-070 UNITS


COMPONENT
ECONOMIZER
FILTERS
30% Pleated (2-in.)
Bags with Prefilters
4-in. Filters (field convert)
Cartridge Filters
POWER EXHAUST (48/50P2, P3 Units)
POWER EXHAUST (48/50P4, P5 Units)
LOW GAS HEAT (48P2,P3 Units)
HIGH GAS HEAT (48P2,P3 Units)
LOW GAS HEAT (48P4,P5 Units)
HIGH GAS HEAT (48P4,P5 Units)
ELECTRIC HEAT*
36 kW
72 kW
108 kW
HYDRONIC COIL
HIGH-CAPACITY COIL (055-070)
Humidi-MiZer SYSTEM

AIRFLOW (cfm)
18,000 20,000 22,000
0.12
0.14
0.16

10,000
0.05

12,000
0.07

14,000
0.08

16,000
0.10

0.00
0.45
0.06
0.42
0.03
0.12
0.14
0.21
0.11
0.19

0.00
0.56
0.08
0.52
0.04
0.17
0.18
0.26
0.14
0.30

0.01
0.68
0.09
0.62
0.05
0.22
0.22
0.32
0.18
0.40

0.01
0.81
0.11
0.73
0.07
0.28
0.27
0.37
0.23
0.51

0.02
0.94
0.13
0.84
0.08
0.34
0.31
0.43
0.27
0.62

0.02
1.08
0.15
0.96
0.10
0.42
0.36
0.50
0.32
0.73

0.15
0.055
0.09

0.20
0.081
0.11

0.07
0.10
0.13
0.26
0.108
0.14

0.09
0.13
0.17
0.32
0.136
0.17

0.12
0.16
0.22
0.39
0.165
0.20

0.15
0.20
0.26
0.47
0.194
0.23

24,000
0.19

26,000
0.21

28,000
0.24

30,000
0.26

0.03
1.22
0.17
1.08
0.12
0.50
0.41
0.56
0.37
0.85

0.03
1.38
0.19
1.21
0.14
0.59
0.47
0.63
0.42
0.97

0.04

0.22

0.17
0.68
0.52
0.70
0.48
1.09

0.05

0.24

0.19
0.78
0.59
0.78
0.54
1.21

0.06

0.27

0.22
0.82
0.65
0.86
0.60
1.34

0.18
0.24
0.32
0.55
0.224
0.27

0.21
0.29
0.38
0.64
0.255
0.31

0.24
0.34
0.44
0.73
0.287
0.35

0.28
0.39
0.51
0.83
0.320
0.38

0.32
0.45
0.59
0.94
0.353
0.43

*Available on vertical return and discharge units only.


For interpolation purposes only. Outside of operating limits.
NOTE: Power exhaust pressure drop does not need to be added to supply fan static pressure on return fan units and on high-capacity power
exhaust units.

125

Performance data (cont)


COMPONENT PRESSURE DROPS (in. wg) (cont)
SIZE 075-100 UNITS
COMPONENT
ECONOMIZER

FILTERS
30% Pleated (2-in.)
65% Pleated (2-in.)
4-in. Filters (field convert)
POWER EXHAUST (48/50P2, P3 Units)
POWER EXHAUST (48/50P4, P5 Units)
LOW GAS HEAT (48P2,P3 Units)
HIGH GAS HEAT (48P2,P3 Units)
LOW GAS HEAT (48P4,P5 Units)
HIGH GAS HEAT (48P4,P5 Units)
ELECTRIC HEAT*
108 kW
216 kW

AIRFLOW (cfm)
27,000
30,000
33,000
0.22
0.26
0.30

15,000
0.10

18,000
0.12

21,000
0.15

24,000
0.19

36,000
0.34

39,000
0.39

42,000
0.43

44,000
0.47

0.01
0.14
0.10

0.01
0.15
0.13

0.02
0.17
0.16

0.02
0.18
0.19

0.03
0.19
0.23

0.04
0.21
0.27

0.05
0.23
0.31

0.06
0.25
0.35

0.07
0.27
0.39

0.08
0.29
0.44

0.09
0.31
0.47

0.06
0.25
0.24
0.34
0.21
0.51

0.08
0.35
0.31
0.43
0.29
0.70

0.11
0.46
0.39
0.53
0.37
0.91

0.14
0.59
0.47
0.63
0.45
1.13

0.18
0.73
0.55
0.74
0.53
1.37

0.22
0.90
0.65
0.86
0.61
1.62

0.27
1.07
0.75
0.98
0.70
1.89

0.32
1.27
0.86
1.11
0.78
2.17

0.37
1.48
0.97
1.24
0.87
2.47

0.43
1.71
1.09
1.38
0.96
2.79

0.47
1.84
1.18
1.48
1.02
3.01

0.05
0.08

0.07
0.12

0.10
0.16

0.13
0.20

0.16
0.26

0.20
0.32

0.24
0.39

0.29
0.46

0.34
0.54

0.40
0.63

0.44
0.69

HYDRONIC COIL

0.15

0.20

0.26

0.32

0.39

0.47

0.55

0.64

0.73

0.83

0.94

HIGH-CAPACITY COIL (075-100)

0.122

0.165

0.209

0.255

0.304

0.353

0.405

0.458

Humidi-MiZer SYSTEM (075)


Humidi-MiZer SYSTEM (090,100)

0.16
0.13

0.20
0.16

0.25
0.20

0.31
0.25

0.37
0.29

0.43
0.35

0.50
0.40

0.58
0.46

0.514
0.66
0.52

0.570
0.74
0.58

0.609
0.80
0.63

*Available on vertical return and discharge units only.


For interpolation purposes only. Outside of operating limits.
NOTE: Power exhaust pressure drop does not need to be added to supply fan static pressure on return fan units and on high-capacity power
exhaust units.

126

Electrical data
Please refer to the RTUBuilder software for the unit electrical data. The unit electrical data may also be found in the
unit Installation Instructions.

SUPPLY FAN MOTOR LIMITATIONS (SIZES 030-070)


NOMINAL

MAXIMUM

Bhp

BkW

7.5

5.60

10

7.46

15

11.19

20

14.92

25

18.65

30

22.38

40

29.84

Bhp
8.7
9.5
10.2
11.8
15.3
18.0
22.4
23.4
28.9
29.4
35.6
34.7
42.0

MAXIMUM AMPS
230 v
460 v
22.0

12.0
28.0

15.0
43.8

21.9
58.2

28.7
73.0

36.3
82.6

41.7

55.0

BkW
6.49
7.09
7.61
8.80
11.41
13.43
16.71
17.46
21.56
21.93
26.56
25.89
31.33

RATED
EFFICIENCY
91.7
91.7
91.7
91.7
93.0
93.0
93.6
93.6
93.6
93.6
93.6
93.6
94.5

LEGEND
Bhp Brake Horsepower
BkW Brake Kilowatts
NOTES:
1. Extensive motor and electrical testing on the Carrier units has
ensured that the full horsepower range of the motor can be utilized
with confidence. Using fan motors up to the horsepower ratings
shown in the Motor Limitations table will not result in nuisance tripping or premature motor failure. Unit warranty will not be affected.
2. All motors comply with the Energy Independence Security Act
(EISA) of 2007.

SUPPLY FAN MOTOR LIMITATIONS (SIZES 075-100)


NOMINAL
HP

BkW

MAX BHP

MAX BkW

30
40
50
60
75

22.4
29.8
37.3
44.8
59.5

34.7
42.0
57.5
69.0
86.25

25.9
31.3
42.9
51.5
64.3

MAX AMPS
460 V
48.0
55.0
71.0
75.0
95.5

575 V
N/A
N/A
N/A
N/A
N/A

RATED
EFFICIENCY
93.6
94.5
94.5
95.4
95.4

LEGEND
Bhp Brake Horsepower
BkW Brake Kilowatts
N/A Not Available
NOTES:
1. Extensive motor and electrical testing on the Carrier units has
ensured that the full horsepower range of the motor can be utilized
with confidence. Using fan motors up to the horsepower ratings
shown in the Motor Limitations table will not result in nuisance tripping or premature motor failure. Unit warranty will not be affected.
2. All motors comply with the Energy Independence Security Act
(EISA) of 2007.

127

Electrical data (cont)


OPTIONAL HIGH-CAPACITY POWER EXHAUST SYSTEMS MOTOR LIMITATIONS (SIZES 075-100)
NOMINAL
HP

BkW

MAX BHP

MAX BkW

20
30
40
50
60

14.9
22.4
29.8
37.3
44.8

23.6
36.0
46.8
58.8
69.0

17.6
26.9
34.9
43.9
51.5

LEGEND
Bhp Brake Horsepower
BkW Brake Kilowatts
NOTES:
1. Extensive motor and electrical testing on the Carrier units has
ensured that the full horsepower range of the motor can be utilized
with confidence. Using fan motors up to the horsepower ratings
shown in the Motor Limitations table will not result in nuisance tripping or premature motor failure. Unit warranty will not be affected.
2. All motors comply with the Energy Independence Security Act
(EISA) of 2007.

128

MAX AMPS (EA)


460 V
575 V
15.0
N/A
21.9
N/A
28.7
N/A
36.3
N/A
41.7
N/A

RATED
EFFICIENCY
91.7
93.0
93.6
93.6
93.6

Controls
Control components
The 48/50P Series rooftops use the ComfortLink control
system that has been developed for use in Carrier Commercial equipment. The control system monitors all operating
conditions in the rooftop unit as well as controlling the compressors, economizers, fans, heat and other devices. It also
has the capability of communicating with the Carrier Comfort Network devices using the CCN protocol and other
popular protocols including BACnet, MODBUS, LonWorks,
etc.
The system uses a microprocessor and a series of boards,
each with inputs and outputs. A local network communications bus (LEN) ties all the boards together into a system and
enables the boards to communicate.
For the 48/50P Series, the control consists of the following key components:
Main base board (MBB) The MBB is the center of
the ComfortLink control system. It contains the major portion of the operating software and controls the operation
of the unit. The MBB continuously monitors inputs and
controls outputs, as well as sends and receives data over
the LEN and CCN communications channels. The board is
located in the main control box.
Rooftop control board (RXB) The RXB controls
many unit functions. The RXB controls the actuators for
the economizer hydronic heating valve and humidifier
valve using a digital communications signal. This signal also
provides operation and diagnostic data on the actuators.
The RXB also has relay outputs to control condenser fans,
second stage power exhaust, minimum load valve and the
heat interlock output. The RXB board is located in the
main control box.
Compressor expansion board (CXB) The CXB
provides additional compressor control outputs and is used
on models with more than four compressors. This board is
located in the main control box.
Options control board (EXB) The EXB is used on
units with the optional return fan, digital scroll compressors or when control of a humidifier is required. This board
is located in the main control box.
Expansion valve board (EXV) The EXV board is located in the main control box.
Staged gas heat board (SCB) When the optional
staged gas heat is used, the SCB board will be installed and
control the operation of the gas valves. It also provides additional sensors for monitoring of the supply-air temperature. This board is located in the main control box.
Modulating gas heat boards When the optional
modulating gas heat is used, one timer relay board (TR1)
and one signal conditioner board (SC30) will be installed in
the heating compartment. The two boards in combination
with SCB board provide control to the modulating gas heat
section. Refer to the Unit Controls and Troubleshooting
book for information on modulating gas control.
Integrated gas controller (IGC) One IGC is provided with each bank of gas heat exchangers. It controls the
direct spark ignition system and monitors the rollout
switch, limit switches, and induced-draft motor Hall Effect
sensor. For units equipped with modulating gas heat, the

induced-draft motor function is proven with a pressure


switch. The IGC is equipped with an LED for diagnostics.
Controls expansion module (CEM) The optional
expansion module is used to provide inputs for supply air
set point reset, static pressure reset, demand limiting, outdoor air quality and other optional inputs. It is located in
the main control box.
Compressor
protection
Cycle-LOC
board
(CSB) This board monitors the status of the compressor by sensing the current flow to the compressors and
then provides digital status signal to the MBB.
Scrolling marquee display This device is the keypad
interface used to access the control information, read sensor values, test the unit, and monitor alarm status. The
scrolling marquee display is a 4-key, 4-character, 16-segment LED (light-emitting diode) display. The display is very
easy to operate using 4 buttons and a group of 11 LEDs
that indicate the following menu structures:
Run Status
Outputs
Service Test
Configuration
Temperatures
Timeclock
Pressures
Operating Modes
Set Points
Alarms
Inputs
Through the display, inputs and outputs can be checked
for their value or status. Because the unit is equipped with
suction pressure transducers and discharge saturation temperature sensors it can also display pressures typically obtained from gages. The control includes a full alarm history
which can be accessed from the display. Through the display, a built-in test routine can be used at start-up commission and during maintenance inspections to help diagnose
operational problems with the unit.

Cooling control options


When mechanical cooling is required, the P Series ComfortLink controls have the capability to control the staging
of the compressors in several different ways. Two scroll
compressors are used on size 030 and 035 units, three
scroll compressors on 040 units, four scroll compressors
are used on sizes 050 to 075 and six scroll compressors
are used on sizes 090 and 100. In addition, a digital unloading type scroll compressor is standard on 30 and 35
ton VAV units and available as an option on all other units.
The ComfortLink controls also support the use of an optional minimum load hot gas bypass valve (MLV) with the
Multiple Adaptive Demand and VAV control sequences.
The MLV is directly controlled by the ComfortLink controls and provides an additional stage of capacity as well as
low load coil freeze protection. The control also integrates
the use of an economizer with the use of mechanical cooling to allow for the greatest use of free cooling. When both
mechanical cooling and the economizer are being used,
the control will use the economizer to provide better temperature control and limit the cycling of the compressors.
129

Controls (cont)
The control also checks on various other operation parameters in the units to make sure that safety limits are not exceeded and the compressors are reliably operated.
The P Series ComfortLink controls offers three control
approaches to mechanical cooling: constant volume,
SAV, and VAV, all with multiple stages of cooling.
COOLING CONTROL OPTIONS
CONTROL TYPE

COOLING CONTROL
METHOD

Unit

Application

Demand Source

P2,P4

CV,SAV

SPT or TSTAT

Multiple Adaptive Demand

P3,P5

VAV

RAT or SPT

Multiple Stage EDT

Control type The control type determines the selection of the type of cooling control as well as the technique
for selecting a cooling mode. The control types are:
VAV-RAT and VAV-SPT Both of these configurations
refer to standard VAV operation. If the control is occupied,
the supply fan is run continuously and return-air temperature will be used in the determination of the selection of the
cooling mode. VAV-SPT differs from VAV-RAT only in that
during the unoccupied period, space temperature will be
used instead of return-air temperature to start the fan for
ten minutes before the return-air temperature is allowed to
call out any mode.
CV SAV TSTAT-Multiple Stage This configuration will
force the control to monitor the thermostat inputs (Y1,Y2)
to make a determination of mode. Unlike traditional 2stage thermostat control, the unit is allowed to use multiple
stages of cooling control and perform VAV-style capacity
control.
CV SAV SPT-Multiple Stage This configuration will
force the control to monitor a space temperature sensor to
make a determination of mode. The unit is allowed to use
multiple stages of cooling control and perform VAV-style
capacity control.
Cooling control method Two different cooling control methods are used to step through the available stages
of capacity. Depending on the unit size, cooling control
method and presence of an MLV, this may range from 2
up to 5 stages of capacity control. These methods are:
Multiple Stage Evaporator Discharge Temperature
(EDT) The capacity of the economizer and compressors
are controlled based on the evaporator air discharge temperature and supply air temperature set point. This control
method uses an adaptive PID (proportional, integral, derivative) algorithm to calculate the estimated change in supply-air temperature before engaging or disengaging the
next stage of cooling. The algorithm compensates for varying conditions, including changing flow rates across the
evaporator coil, to provide better overall control of compressor staging.
Multiple Adaptive Demand This control method will
base the capacity of the economizer and compressors on
the evaporator air discharge temperature and one of two
supply air temperature set points. The control will be able
to call out a LOW COOL or a HIGH COOL mode and

130

maintain a low or high cool supply air set point. The unit
will use either the input from a conventional thermostat to
turn the Y1, Y2 signals into a high and low demand signal,
or with a space temperature sensor use a differential from
set point to determine the mode. Once the mode has been
established the control uses the same algorithm as with
VAV control.
Integrated economizer For each of the above modes
of operation all mechanical cooling will first be delayed
while the unit attempts to use the economizer for free cooling. Once the economizer is at full capacity, the control will
then supplement the free cooling with as much mechanical
cooling as required. To prevent any rapid changes in cooling, the control will also use the economizer to trim the
cooling supplied.

Heating control options


When heating is required the P Series units can be provided with 2-stage electric heat, 2-stage gas heat, multiplestage gas heat, modulating gas heat or modulating hydronic heat. Depending on unit size and heating capacity the
multiple-stage gas heating option may have between 5 and
9 stages of heating capacity control. Modulating gas heat
provides variable heating loads depending on unit size and
overall heating capacity. The P Series ComfortLink controls have the capability to control the heating capacity
based on input from a 2-stage mechanical thermostat, a
space temperature sensor, or on VAV units by the return
air temperature sensor. With CV units the heating mode
(off, low or high) will be enabled based on W1 and W2
thermostat inputs, or when using a space temperature sensor the differential from heating set point will be used.
Heating with VAV units will be enabled based on the return-air temperature or the space temperature, but once
enabled control will be based on the return-air temperature. Variable air volume terminals will be commanded
open to the heating cfm through linkage or the heat interlock relay. The P Series ComfortLink controls will use one
of the following control methods:
Two-stage control (gas or electric heat) The unit
will operate in LOW HEAT or HIGH HEAT mode as determined by the demand inputs. In the LOW HEAT mode if
the temperature sensed by the evaporator discharge temperature sensor is below 50 F, the unit will automatically go
into a HIGH HEAT mode.
Multiple-stage and modulating control (gas heat
only) When the unit is in a LOW HEAT mode the algorithm calculates the desired heat capacity based on set
point and supply-air temperature. The staged gas control
logic will stage the heating capacity to match the calculated
demand. Units with modulating control logic will continuously modulate the heating capacity to match the calculated demand. When the unit is in a HIGH HEAT mode all
stages of heat will be activated. In case the modulating option is selected, the control will maintain the maximum
heating capacity. Both staged and modulating gas heat options can also be used in a TEMPERING mode. This mode
is enabled during a VENTILATION, LOW COOL or HIGH
COOL mode when the economizer dampers are at their
minimum ventilation position and the mixed-air
temperature is below the supply air set point. Tempering

can also be used during a preoccupancy purge to prevent


low temperature air from being delivered to the space.
Modulating hydronic coil control When the unit is
in a LOW HEAT mode the algorithm calculates the desired
heat capacity based on set point and supply-air temperature. The valve control logic will modulate the heating capacity to match the calculated demand. When the unit is in
a HIGH HEAT mode the modulating valve will go to a full
open position. Modulating hydronic heat can also be used
in a TEMPERING mode. This mode is enabled during a
VENTILATION, LOW COOL or HIGH COOL mode when
the economizer dampers are at their minimum ventilation
position and the mixed-air temperature is below the supply
air set point. Tempering can also be used during a preoccupancy purge to prevent low temperature air from being delivered to the space.

Economizer and IAQ options


The controls have been designed to support the requirements of indoor air quality control through the use of outside air. Units can either be equipped with an outside air
adjustable, self-closing economizer or a fully modulating,
gear driven economizer with no linkages. The economizer
can be configured for a full modulation mode or 3-position
mode of operation. The control includes logic for a minimum ventilation position and different set points for occupied and unoccupied minimum position set points. This
control also has logic built in to calibrate the economizer
position to the actual percentage of outside air introduced.
During periods when the compressors are not being used
the control will use the RAT, SAT and OAT to calibrate the
economizer. This will allow for setting the outside air actual
percentage and not just the percent damper position.
The use of the economizer will depend on the mode of
change selected. This control integrates the changeover directly into the control. Five types of changeover are
available:
Outdoor air dry bulb
Differential dry bulb
Outdoor air enthalpy
Differential enthalpy
Outdoor air dew point
The units are provided with an outdoor air and return air
temperature sensor so the first two changeover methods
are available as standard. To use the enthalpy changeover
options the control supports the addition of highly reliable,
electronic humidity sensors. The humidity sensor input is
then used with the dry bulb sensors to calculate the enthalpy. For outdoor enthalpy changeover the control also has
the ASHRAE 90.1 A, B, C, D economizer changeover
curves built into the software. When operating with outside
air economizers, large amounts of air can be introduced
into the building and a means must be provided for building
pressure relief. The 48/50P Series control supports the
following types of building pressure control:
Barometric Relief Dampers Can be used on low
return duct static applications
Non-Modulating Two-Stage Power Exhaust The unit
can be equipped with two power exhaust fans. The

software controls the power exhaust stages based on


the economizer position (percent open).
Modulating Power Exhaust Both the VAV and CV
units can be equipped with modulating power exhaust.
The exhaust airflow is controlled by the use of a VFD
on both exhaust fans. The ComfortLink controls modulate the fan speed to maintain the building pressure set
point.
High-Capacity Modulating Power Exhaust (size 075100 units only) Both the VAV and CV units can be
equipped with high-capacity modulating power exhaust.
The exhaust airflow is controlled by the use of a VFD
on the lead exhaust fan. The ComfortLink controls
modulate the lead fan speed to maintain the building
pressure set point. The second exhaust fan is energized
when additional exhaust airflow is required.
Modulating Return Fan (size 075-100 units only)
Both the VAV and CV units can be equipped with modulating return fan. The primary function of a return fan
is to handle return duct losses, allowing the supply fan
to handle only internal and supply static load. Return
fans should never be used on systems with less than
0.5-in. wg return static. The return fan runs whenever
the supply fan is operating and its speed is controlled by
a variable frequency drive. The ComfortLink controls
measure the supply fan airflow and adjusts the return
fan speed to maintain a programmed airflow differential. The airflow differential is dynamically adjusted to
maintain building pressure set point.
The units are capable of using either 2-in. fiberglass/
pleated media, 12-in. deep cartridge filters (030-070 only)
or optional 22-in. deep bag filters (size 030-070 units only)
and can have an optional filter pressure drop switch to
warn of dirty filter conditions. Additionally the standard
2-in. angle filter track can be field modified to accept 4-in.
deep filters.
The indoor air quality (IAQ) function provides a demandbased control for ventilation air quantity, by providing a
modulating outside air damper position that is proportional
to the space CO2 level. The ventilation damper position is
varied between a minimum ventilation level (based on internal sources of contaminants and CO2 levels other than the
effect of people) and the maximum design ventilation level
(determined at maximum populated status in the building).
During a less-than-fully populated space period, the CO2
level will be lower than that at full-load design condition
and will require less ventilation air. Reduced quantities of
ventilation air will result in reduced operating costs. Space
CO2 levels are monitored and compared to user-configured
set points. Accessory CO2 sensor for space (or return duct
mounting) is required. The IAQ routine can be enhanced
by also installing a sensor for outdoor air quality.
During the occupied period, in the absence of a demand
for cooling using outside air, if CO2 levels are below the set
point for the minimum ventilation level, the outside-air
damper will open to the minimum ventilation level damper
position set point. The minimum damper position will be
maintained as long as the CO2 level remains below the set
point.

131

Controls (cont)
When the space CO2 level exceeds set point for the minimum ventilation level condition, the ComfortLink controls
will begin to open the outside air damper position to admit
more ventilation air and remove the additional contaminants. As the space CO2 level approaches the set point for
maximum design ventilation level condition, the outside air
damper position will reach the maximum ventilation level
damper position set point limit. Damper position will be
modulated in a directly proportional relationship between
these two CO2 set point limits and their corresponding
damper position limits.
In most applications a fixed reference value can be set for
the outdoor air quality level, but the control also supports
the addition of an outdoor air quality sensor that will be
compared to the indoor or return IAQ sensor. If an OAQ
(outdoor air quality) sensor is connected, the demand set
point levels will be adjusted automatically as the outdoor
CO2 levels vary. Also, if the outdoor CO2 level exceeds a
user-configured maximum limit value, then outside air
damper position will be limited to the minimum ventilation
damper set point value. The control can also receive these
signals through the CCN system.
The IAQ and OAQ measurement levels are displayed by
the ComfortLink scrolling marquee in parts per million
(ppm).
Outdoor air CFM control Minimum space ventilation requirements can also be maintained by applying the
minimum outdoor air cfm control option. This option provides an airflow monitoring station at the outside air damper inlet. The ComfortLink controls can be programmed to
monitor this airflow rate and to override the current outside
air damper position to maintain a minimum quantity of
outdoor air at the users design set point even as the units
supply fan slows during part load operating periods.
Fire and smoke controls interface The unit can be
equipped with an optional return air smoke detector. The
smoke detector is wired to stop the unit and send a message to a remote alarm system if a fault condition is detected. If the controls expansion module is added, the control
will support smoke control modes including evacuation,
smoke purge, and pressurization.
Demand limiting The control supports demand limiting using one or two fixed capacity limits initiated by discrete input switches or a variable capacity limit function
based on an analog input signal. On CCN systems this can
be done through the network, or for non-CCN network
jobs this can be done by adding the controls expansion
module.

Diagnostics
The ComfortLink controls have fully integrated all controls
and sensors into a common control system. The control
monitors these inputs as well as many of the routines to
provide advanced diagnostics and prognostics. These include adaptive logic to allow the unit to continue to operate
in a reduced output mode and automatic resets where applicable. The last 10 alarms and alerts are stored in memory and can be accessed through the display. The alarms
can also be monitored through the Carrier Comfort Network connection. The unit also supports the use of the

132

hand held Navigator display which can be plugged in at


the main control box and auxiliary control box at the opposite end of the unit.
Some of the diagnostics that are included are:
Monitoring of all sensors
Suction pressure transducers to provide compressor
protection and coil freeze protection
Monitoring of the economizer motor using a digitally
controlled motor
Monitoring of compressor status using compressor protection boards
Adaptive logic for low supply-air temperatures
Compressor lockout at low ambient conditions
Storage of compressor run hours and starts
Low refrigerant charge protection
Compressor reverse rotation protection

Control interface
The ComfortLink controller can interface with an i-Vu
Open control system, a BACnet building automation system, or Carrier Comfort Network devices. This will allow
for the use of all system control programs. These include:
Network Service Tool
System Pilot device
Touch Pilot device
i-Vu Open control system software
ComfortVIEW software
CCN Web software
ComfortID system
Contact Carrier Controls Marketing for more information. The control can also provide interface with other energy management systems with the addition of either the
BACnet/MODBUS Carrier translator or the LonWorks
Carrier translator.
Several contact connection points have been provided in
the main control box for interface to external controls and
systems. These are summarized in the Interface Connection table. External controls use the following interface
points:
Start/Stop (On/Off) Start/Stop is accomplished with
a contact closure between terminals 3 and 4 on TB201.
Remote Economizer Enable Enabling and disabling
of the economizer can be done by connecting a contact
closure to terminals 5 and 6 on TB201. The economizer can be configured for a switch closure changeover
for 3-position operation.
VAV Heating Interlock Interface with non-linkage
terminals can be done through TB201 terminals 9 and
10.
Remote IAQ Inputs External IAQ demand inputs can
be connected through terminals 7 and 8 on TB201.
Smoke Detectors Alarm Output Remote detector
alarm outputs can be connected through terminals 1
and 2 on TB201.
Fire Shutdown A remote fire shutdown signal can be
connected to 1 and 2 on TB201. The software can be
configured to shut the unit down on an open or closed
signal.
Fire Pressurization For a remote control of pressurization a contact closer can be connected to terminals

18 and 19 on TB202. In this mode the economizer


damper will be fully opened and the supply fan turned
on to pressurize the space.
Fire Evacuation For this mode a remote contact closure can be connected to terminals 16 and 17 on
TB202. For remote evacuation of a space the outsideair dampers will be opened and the power exhaust fans
turned on to evacuate the space of smoke.
Fire Purge For this mode external contacts can be
connected to terminals 14 and 15 on TB202. In this
mode the supply fan and return fans will be turned on
with the economizer at a full open position.
Demand Limiting For demand limiting the controls
expansion module must be used. Connections are provided on TB202 for switch input demand limiting (terminals 20 and 21, 22 and 23) and for 4 to 20 mA
(terminals 10 and 11) demand limit signals.
Dehumidification A discrete input is available on
TB202, terminals 24 and 25 to initiate the Dehumidification mode.
Remote Supply Air Set Point A remote supply air
temperature set point reset can be supported when the
controls expansion module is used. This input requires a
4 to 20 mA signal. It can be connected to terminals 8
and 9 on TB202.
Remote Static Pressure Reset Set Point A remote
supply air temperature set point reset can be supported
when the controls expansion module is used. This input
requires a 4 to 20 mA signal. It can be connected to terminals 7 and 8 on TB202. This input is shared with the
Outdoor Air IAQ signal.
Outdoor Air IAQ Signal If an external outdoor air
signal is being used then it can be connected to terminals 7 and 8 on TB202. This input requires a 4 to
20 mA signal. This input is shared with the Remote
Static Pressure Reset signal.
IAQ Switch Input If an external control will be controlling IAQ then it can be connected as a contact closure through terminals 12 and 13 on TB202.
Space Humidity A space humidity sensor can be
used to enable the dehumidification and humidifier control logic. It can be connected to terminals 3 and 4 on
TB202. This input requires a 4 to 20 mA signal.
Humidifier Control Output A contact closure out can
be provided to enable the operation of a field-provided
humidifier. The output can be connected to terminals 1
and 2 on TB201.
Carrier can also support electronic interface to other systems using the following;
BACnet/MODBUS Carrier translator (read/write, provides CCN to BACnet master-slave/twisted-pair [MS/
TP] or MODBUS remote terminal unit [RTU] protocol
conversion)
LonWorks Carrier translator (read/write, provides CCN
to LON FT-10A ANSI/EIA-709.1 protocol conversion)

Constant volume and staged air volume


applications
The 48/50P2,P4 units are designed to operate in CV and
SAV applications. The units are shipped as operable,
stand-alone units using either a standard (mechanical or

electronic) 2-stage heat, 2-stage cool thermostat, or with


an electronic room temperature sensor and a timeclock to
establish unit start and stop times. With a standard thermostat (programmable is optional), heating and cooling operation is set by space temperature. With a space sensor and
field-supplied timeclock, the machine will operate at default
values unless they are changed using appropriate input devices. The space sensor monitors space temperature and
may be equipped with a timed override feature, which allows unit operation during unoccupied periods. The space
sensors may be used in multiples of 4 or 9 to achieve space
temperature averaging. The use of a space sensor also allows the unit to be turned on and off from a remote signal
or it can be programmed to use the time of day scheduling
that is built into the control.
Features with thermostat control of unit
Two-stage heating (if installed)
Multiple stage gas heating if unit is equipped with the
staged gas heat option
Modulating gas heating if unit is equipped with the modulating gas heat option
Two-stage demand with fully proportional economizers
and integrated compressor capacity
Adaptive multiple stage cooling which can provide up to
6 stages of capacity
Control of unit using Y1, Y2, W1, W2, and G thermostat or T55, T56, or T58 space sensors
Control of the indoor fan
Outdoor-air temperature/supply-air temperature monitoring with logic to lock the compressors out at low
ambient temperatures down to 32 F (20 F with Motormaster control)
Control of a condenser fan based on outdoor-air and
condensing pressures
Control of modulating economizer to provide free cooling when outdoor conditions are suitable
Control allows for use of the economizer and the compressors to maximize the use of outside air cooling to
reduce part load operating costs
Control of the power exhaust fans based on configurable economizer damper positions or directly from the
optional building pressure sensor
Compressor time guard override (power up and minimum on and off timers) to assure air return in low load
conditions
Support of IAQ sensor
Features with sensor control of unit There are 3
sensor options available:
T55 sensor will monitor room temperature and provide
unoccupied override capability (1 to 4 hours).
T56 sensor will monitor room temperature, provide
unoccupied override capability (1 to 4 hours), and provide a temperature offset of 5 F maximum.
T58 is a CCN communicating sensor that will provide
the set point and space temperature values.
Standard features are:
Support of remote occupied/unoccupied input to start
and stop the unit
Two-stage economizer demand with fully proportional
economizers and integrated compressor capacity
133

Controls (cont)
Adaptive cooling capacity control with up to 6 stages of
mechanical refrigeration capacity
Variable capacity control with digital scroll compressor
option
Occupied or unoccupied set point
Enable heating (if installed) or cooling during unoccupied periods as required to maintain space temperature
within the unoccupied set points
Adjustment of space temperature set points of 5 F
when using a T56 sensor
Support of IAQ sensor
365-day timeclock with backup (supports minute, hour,
and day of week, date, month, and year access). The
timeclock includes the following features:
Daylight savings time function
Occupancy control with 8 periods for unit operation
Holiday table containing up to 18 holiday schedules
Ability to initiate timed override from T55 or T56
sensors (for a timed period of 1 to 4 hours)
Temperature compensated start to calculate early
start times before occupancy
For units connected into a CCN network the time
clock can be integrated into the overall building
energy management system and be updated
remotely
For units connected to the CCN network the user can
also display all the unit information including I/O values
Maintenance, Configuration, Service, and Set Point
data tables
Indoor air quality (IAQ)

Variable air volume (VAV) applications


The 48/50P3,P5 units are designed to operate in VAV applications. As an option, they include a supply fan inverter
(VFD) to control the supply fan speed and duct pressure.
They are designed to control the leaving-air temperature in
cooling to a configurable set point. The changes in mode
of operation from Heating to Vent to Cooling mode can be
controlled either from the return air temperature sensor or
from an accessory space temperature sensor. Some of the
features for VAV units in a stand-alone application are:
The units are shipped as operable, stand-alone units
with the addition of a field-supplied timeclock to establish unit start and stop times or they can use ComfortLink time of day scheduling routine
Provide cooling and heating control (if equipped with
heat) in both occupied and unoccupied modes
Supports an optional space temperature sensor for
mode control and supply air temperature reset
If space sensor is equipped with an override feature, the
sensor will allow operation during the unoccupied
period for a fixed length of time
Base unit control supports a heat interlock relay (field
supplied) to signal the VAV terminal devices to fully
open during heating operation
Control board diagnostics
Control of an outdoor-condenser fan based upon outdoor-air temperature and saturated condensing temperature
Control of modulating economizer to provide free cooling when outdoor conditions are suitable.

134

Control also allows for use of the economizer and the


compressors to maximize the use of outside air cooling
to reduce part load operating costs
Support of remote occupied/unoccupied input to start
Controls the operation of the supply fan inverter to
maintain a configurable supply duct static pressure set
point. Inverter is configured and controlled directly by
ComfortLink controls
Support of IAQ sensor
Support a field test for field check out
Support linkage to ComfortID systems
Cooling capacity control of up to 6 stages plus
economizer
Variable capacity control with digital scroll compressor
option
Control of two stages of heat to maintain return-air
temperature
Multiple stage gas heating if unit is equipped with the
staged gas heat option
Control of heat interlock relay
Compressor time delays to prevent rapid cycling of
compressors
Automatic lead-lag control of compressors to reduce the
number of compressor cycles
With the addition of a remote start/stop switch heating
or cooling is enabled during unoccupied periods as
required to maintain space temperature to within unoccupied set points
With the addition of the controls expansion board, the
ComfortLink controls will also support demand limiting
and remote set point control
When the unit is connected to a CCN (Carrier Comfort
Network) system, additional features can be used:
Interface of the unit clock with the CCN network clock
and allow for remote configuration of the schedules
CCN demand limit participation
Interface with ComfortID control systems through
linkage

Sequence of operation
Cooling, constant volume (CV, SAV) units
On power up, the control module will activate the
initialization software. The initialization software will
determine the unit configuration and also initialize any
controls loops and input/output devices. All alarms and
configurations are saved in memory and maintained during
power outages. All alarms will be maintained in memory
and must be cleared through the display.
Constant volume and staged air volume conventional thermostat control If the unit is equipped with
a conventional thermostat with Y1, Y2, W1, W2 and G
connections then the control will perform the following
sequence.
When G is closed the indoor fan will turn on. G must be
closed for heating or cooling to occur. If Y1 is closed then
the control will first check the ability to use the economizer.
If the economizer can be used, the control will modulate
the damper open to maintain the low load economizer
leaving air temperature set point. If Y2 closes then the control will lower the leaving air temperature set point to the
configured set point. If the economizer can not satisfy the

load then compressors will be sequenced on to maintain


either the low or high load temperature set points. If the
economizer can not be used or the enable control disables
the economizer, then the control will sequence the compressors based on the Y1 and Y2 signals. The control will
add and remove compressor stages to maintain the low
and high demand leaving air set points. If Y1 is closed at
least one compressor stage will be turned on.
If W1 closes, then it will indicate that the units should be
in the Heating mode. The economizer will be closed to the
minimum position, and if the unit is equipped with gas or
electric heat then the first stage of heat will be energized. If
W2 closes then the control will turn on the second stage of
heat. If the unit is equipped with a staged gas or modulating heat control option then the W1 signal will be used to
control the gas heat to the configurable low heat load leaving air temperature set point. When W2 is energized, the
unit will fire all stages of heat capacity. If the unit is
equipped with gas heat then the IGC board will control the
operation of the gas heat. See the 48 Series Gas Heat
units section for the IGC board sequence of operation.
If the unit has hydronic heat option then the W1 signal
will control the modulating control valve to the configurable low heat load leaving air temperature set point. When
W2 is energized, the modulating control valve will go to a
100% open position.
Constant volume and staged air volume space temperature sensor control If the space temperature
operation has been selected using a T55, T56, or T58 sensor then the following logic will be used to control the operation of the unit.
If a space temperature is used then a wire jumper must
be added between R, W1, and W2. If a remote occupancy
control method has been selected then the input must first
be closed for the unit to go into Heat, Vent or Cooling
mode. If the internal timeclock is used, the control module
determines the occupancy state based on the system time
schedules. If Temperature Compensated Start is active, the
unit will be controlled as in the occupied mode and will
start a time as determined by prior operation to have the
space at set point by the occupied time. If the unit has been
configured for a preoccupancy purge then the control will
start the unit in Vent mode prior to the occupancy time to
vent the space. If an IAQ sensor is being used and the low
IAQ set point is satisfied then the occupancy purge mode
will be terminated.
The set points for heat and cooling are configurable
through the display. If a T56 sensor is being used then the
set point can be shifted by as much as 5 degrees. If the
space temperature goes above the cooling set point then
the unit will go into Cooling mode. If the economizer can
be used, the control will first try to control to the leaving air
temperature set point. The set point will depend on the
space temperature. If the temperature is above the low demand set point then the low economizer load discharge air
temperature set point will be used. If the temperature is
above the high load space temperature set point then the
high load leaving air temperature set point will be used. If
the economizer can not satisfy the load then compressors
will be sequenced on to maintain either the low or high

load temperature set points. If the economizer can not be


used or the enable control disables the economizer then
the control will sequence the compressors based on the
low and high load space temperature variables. The control will add and remove compressor stages to maintain the
high and low demand leaving air set points.
If the space temperature goes below the heating space
temperature set points then it will indicate that the units
should be in the Heating mode. The economizer will be
closed to the minimum position and if the unit is equipped
with gas or electric heat then the first stage of heat will be
energized. If the space temperature goes below the high
load space temperature set point then the control will turn
on the second stage of heat. If the unit is equipped with a
staged gas heat control option then the low load demand
signal will turn on heating stages to maintain the leaving air
temperature set point. If the unit is equipped with modulating gas heat control option, then the low load demand signal will continuously modulate the heating load to maintain
the leaving air temperature set point. A high demand signal will energize all stages of heat. The gas modulating section will operate at maximum heating capacity if the modulating option is selected.
If the unit has hydronic heat option then the low load
demand signal will control the modulating control valve to
the configurable low heat load leaving air temperature set
point. A high demand signal will cause the modulating control valve will go to a 100% open position.
If the unit is configured for unoccupied free cooling, mechanical cooling or heating and the temperature goes beyond the unoccupied configuration set points then the control will turn on free cooling, mechanical cooling or heat as
needed to get within the unoccupied set points.
When in this mode, the economizer dampers will be
maintained fully closed or to the minimum unoccupied ventilation set point.
Variable air volume control On power up, the control module will activate the initialization software. The initialization software will determine the unit configuration
and also initialize any controls loops and input/output devices. All alarms and configurations are saved in memory
and maintained during power outages. All alarms will be
maintained in memory and must be cleared through the
display.
The unit will first determine the mode of operation. If
the unit has been configured for space temperature demand then the control will determine, based on the configurable set points, if the unit should be in the heat mode,
vent mode or cooling mode. If the unit is configured for return air temperature control then it will start the fan and
monitor the return air temperature vs. the configurable set
point to determine if the unit should be in cooling, vent or
heating mode.
If the control is connected to a ComfortID system, the
room terminals are equipped with microprocessor controls
that give commands to the base module. If linkage is active,
the control module will replace local ComfortLink set
points and occupancy data with linkage supplied data.

135

Controls (cont)
If temperature compensated start is active then advance
pre-cool or heat of the space is enabled. If the unit is configured to use a pre-purge cycle then the ComfortLink
controls will start the unit in Vent mode based on a prestart time interval. If an IAQ sensor is being used and the
low IAQ control point is satisfied, then the mode will be
terminated.
If Cooling mode is required, then the controlling set
point will be the leaving air temperature set point. If an
economizer is present and the changeover control allows
the economizer to be used, then it will first attempt to control the leaving-air temperature using free cooling. If this
can not satisfy the load, then additional compressor stages
will be turned on to maintain the leaving-air temperature.
When both compressors and economizers are being used,
the control will use the economizer dampers to maintain
better control of the leaving-air and to help prevent high
compressor cycling. If the economizer can not be used
then it will be set to the minimum vent position. When using compressors, the leaving-air temperature will sequence
compressors on and off using a PID control loop. If the
unit is equipped with an optional hot gas bypass valve the
control will use the hot gas as an additional stage of capacity. When the first stage of cooling is required the control
will turn on a circuit A compressor and the hot gas bypass valve. When additional cooling is called for it will turn
off the hot gas bypass valve. The valve will also be used for
additional freeze protection of the coils when low
evaporator refrigerant temperatures are detected using the
suction pressure transducers.
When operating in cooling the control will also monitor
the supply duct pressure and send a 4 to 20 mA signal to
the factory-supplied inverter to control the speed of the fan
and the delivered cfm. If on a linkage system the control
will also support static pressure reset based on the needs of
the zones.
If the unit has been enabled for occupied heat and the
space temperature sensor (SPT), return air temperature
sensor (RAT) or linkage demand calls for heat, the control
will energize the electric heat or gas heat (if present) to
warm the space. In this mode the control will energize the
heat interlock relay which will signal the terminals to open
to the heating position. Note that for the linkage systems
the interlock relay connection is not required. Once the
Heat mode is enabled, the heat capacity will be controlled
by the return air temperature set point. Heating will continue until the return temperature set point is satisfied. If the
unit is configured for morning warm-up and the heating
demand is below the set point during the first 10 minutes
of operation, the control will energize full heating capacity
until the return air temperature set point is satisfied.
If the space temperature sensor (SPT), return air temperature sensor (RAT) or linkage demand requires that the
unit be in heating then the control will energize the electric
heat or gas heat (if present) to warm the space. In this
mode the control will energize the heat interlock relay
which should be connected to the terminals to indicate that
they should open to the heating position. The interlock relay connection is not required for the linkage systems.
Heating will continue until the mode selection sensor is
satisfied.
136

Dehumidification mode A Dehumidification mode


can be initiated by either a discrete input on TB202 or by a
direct measurement of humidity levels with an optional
space or return air humidity sensor. When the Dehumidification mode is active, the evaporator coil leaving air temperature will be controlled to the Dehumidify Cool set
point, which is typically colder than the normal cool mode
leaving air set points.
In this mode, comfort condition set points, which are
based on dry bulb temperature, will be overridden. If a
source of reheat is available, then the leaving-air temperature can be raised to a more desirable temperature. Available methods of reheat are internal gas heat if the unit is
equipped with the staged gas heating option, modulating
hot water heat if the unit is equipment with a hydronic coil,
or an external heat source that can be controlled by a 4 to
20 mA signal.
Humidi-MiZer operation The
design
of
the
Humidi-MiZer adaptive dehumidification system allows for
two humidity control modes of operation of the rooftop
unit, utilizing a common subcooling/reheat dehumidification coil located downstream of the standard evaporator
coil.
This unique and innovative design provides the capability for the rooftop unit to operate in both a subcooling
mode and a hot gas reheat mode for maximum system
flexibility.
The Humidi-MiZer package is factory installed and will
operate whenever there is a dehumidification requirement.
The Humidi-MiZer system is initiated based on input from
a factory-installed return air humidity sensor to the large
rooftop unit controller. Additionally, the unit controller may
receive an input from a space humidity sensor, a discrete
input from a mechanical humidistat, or third-party controller. A unit equipped with a Humidi-MiZer system can operate in the following modes:
Conventional Cooling Mode Conventional operation
of the P Series large rooftop unit allows the unit to cycle up
to six compressors to maintain comfort conditions, with
expanded cycling operation offered by the optional digital
compressor.
This mode is the conventional DX (direct expansion)
cooling method used on Carriers standard large rooftops
and provides equivalent capacity to a non-Humid-MiZer
equipped unit. It is used when there is a call for cooling only, such as at design AHRI (Air Conditioning, Heating, and
Refrigeration Institute) cooling conditions of 95 F ambient
and 80 F/67 F db/wb entering air conditions. The SHR
(sensible heat ratio) for equipment in this scenario is typically 0.7 or higher.
Subcooling Mode This mode will operate to satisfy part
load type conditions when there is a space call for cooling
and dehumidification. Although the temperature (sensible)
may have dropped and decreased the sensible load in the
space, the outdoor and/or space humidity levels may have
risen.
A typical scenario might be when the outside air is 85 F
and 70 to 80% relative humidity (RH). Desired SHR for
equipment in this scenario is typically 0.4 to 0.7. Carriers
P Series Humidi-MiZer adaptive dehumidification system

will increase subcooling entering the evaporator and cycle


on enough compressors to meet the latent load
requirement, while simultaneously adjusting refrigerant
flow to the Humidi-MiZer coil to reheat the air to the required supply air set point. This will allow the unit to provide variable SHR to meet space requirements.
Conversely, a standard unit might overcool the space or
stage down to meet set point, sacrificing latent capacity
control. The Humidi-MiZer unit will initiate subcooling
mode when the space temperature and humidity are both
above the temperature and humidity set points, and attempt to meet both requirements.
Once the humidity requirement is met, the unit can continue to operate in normal cooling mode to meet any remaining sensible capacity load. Alternatively, if the sensible
load is met and humidity levels remain high the unit can
switch to Hot Gas Reheat mode to provide neutral, dehumidified air.
Hot Gas Reheat Mode This mode is used when dehumidification is required without a need for cooling, such as
when the outside air is at a neutral temperature (70 to
75 F) but high humidity exists. This situation requires the
equipment to operate at a SHR of 0.0 to 0.2.
With no cooling requirement and a call for dehumidification, the P Series Humidi-MiZer adaptive dehumidification
system will cycle on enough compressors to meet the latent load requirement, while simultaneously adjusting
refrigerant flow to the Humidi-MiZer coil to reheat the air
to the desired neutral air set point.
The P-Series Humid-MiZer system controls allow for the
discharge air to be reheated to either the return-air temperature minus a configurable offset or to a configurable Reheat set point (default 70 F). The Hot Gas Reheat mode
will be initiated when only the humidity is above the humidity set point, without a demand for cooling.
Mode Control The essential difference between the
Subcooling mode and the Hot Gas Reheat mode is in the
supply air set point. In Subcooling mode, the supply air set
point is the temperature required to provide cooling to the
space. In Reheat mode, the supply air set point is the temperature required to provide neutral air to the space. In
both cases, the unit will decrease the evaporator discharge
temperature to meet the latent load and reheat the air to
the required cooling or reheat set point (i.e., 50, 60, 70 F,
etc.).

48 Series gas heat units


The gas heat units incorporate 1, 2 or 3 separate systems,
depending on unit size and heating capacity, to provide gas
heat. Each system incorporates its own induced-draft motor, integrated gas control (IGC) board, 2-stage gas valve,
manifold, and safeties. The modulating system incorporates an additional modulating gas valve and modulating
gas control. For 2-stage heat control the systems are operated in parallel. For example, when there is a call for first
stage heat, both induced-draft motors operate, both gas
valves are energized, and both IGC boards initiate spark.
With the staged and modulating gas control, the systems
are operated independently to allow for a greater range of
capacity control. All of the gas heating control is performed through the IGC boards (located in the heating

section). There are two additional boards (TR1 and SC30)


for the modulating system, which in combination with the
IGC board control the modulating gas heating. The additional boards are located in the heating section. The MBB
module board serves only to initiate and terminate heating
operation and monitor the status of the requirements for
indoor fan operation. The fan will be controlled directly by
the MBB board. The base module board is powered by
24 vac.
When the thermostat or room sensor calls for heating
the MBB board will close heating relays and send power to
W on each of the IGC boards. An LED on the IGC board
will be on during normal operation. A check is made to ensure that the rollout switches and limit switches are closed
and the induced-draft motors are not running. After the induced-draft motors are energized and speed is proven with
the Hall Effect sensor on the motor. For units equipped
with modulating gas heat the induced-draft motor function
is proven with a pressure switch. When the motor speed or
function is proven, the ignition activation period begins.
The burners will ignite within 5 seconds. When ignition occurs the IGC board will continue to monitor the condition
of the rollout and limit switches, the flame sensor, the Hall
Effect sensor or pressure switch.
If the unit is controlled through a room thermostat set
for fan auto., 45 seconds after ignition occurs the indoorfan motor will be energized and the outdoor-air dampers
will open to their minimum position. If the over temperature limit opens prior to the start of the indoor fan blower,
on the next attempt the 45-second delay will be shortened
to 5 seconds less than the time from initiation of heat to
when the limit tripped. Gas will not be interrupted to the
burners and heating will continue. Once modified, the fan
on delay will not change back to 45 seconds unless power
is reset to the control. If the unit is controlled through a
room sensor, the indoor fan will be operating in the occupied mode and the outdoor-air dampers will be in the minimum position.
If the unit is controlled with a room sensor in the unoccupied mode, the indoor fan will be energized through the
IGC board with a 45-second delay and the outside-air
dampers will move to the minimum unoccupied set point.
When additional heat is required, the second stage MBB
output relay closes and initiates power to the second stage
of all main gas valves in all sections. For units equipped
with modulating system, the second stage is controlled by
the TR1 timer relay board. When the demand is satisfied,
MBB heat output relays will open and the gas valves close
interrupting the flow of gas to the main burners. If the call
for stage 1 heat lasts less than 1 minute, the heating cycle
will not terminate until 1 minute after W1 became active. If
the unit is configured for intermittent fan then the indoorfan motor will continue to operate for an additional 45 seconds then stop and the outdoor-air dampers will close. If
the over temperature limit opens after the indoor motor is
stopped within 10 minutes of W1 becoming inactive, on
the next cycle the time will be extended by 15 seconds.
The maximum delay is 3 minutes.
Once modified, the fan off delay will not change back to
45 seconds unless power is reset to the control.
137

Application data
Ductwork Secure vertical discharge ductwork to roof
curb. Interior installation may proceed before unit is set in
place on roof. For horizontal discharge applications, attach
ductwork to unit, or field-supplied flanges can be attached
to horizontal discharge openings and all ductwork attached
to flanges. Units equipped with electric heat require a
90-degree elbow below the unit supply duct connection.
Thru-the-curb service connections Roof curb
connections allow field power wires and control wires to
enter through the roof curb opening.

Thermostat (CV only) Use of a thermistor-type


room sensor is recommended on all CCN installations. A
thermistor-type room sensor or a 2-stage heating/cooling
thermostat may be used for all other units.
Heating-to-cooling changeover All units are automatic changeover from heating to cooling when automatic changeover thermostat and subbase or a thermistortype room sensor are used.

Airflow Units are draw-thru on cooling and blow-thru

High altitude (gas heat units only) A

change
to the gas orifice may be required at high altitudes. Contact
Carrier Application Engineering.

Minimum temperature Minimum allowable temperature of mixed air entering the heat exchanger during
half rate (first stage) operation is 50 F. There is no minimum mixture temperature during full-rate operation. Comfort conditioning may be compromised at temperatures below 50 F. Below 50 F entering-air temperature (EAT) both
stages of heat are engaged.
Internal unit design Due to Carriers internal unit
design (draw-thru over the motor), air path, and specially
designed motors, the full horsepower listed in the Physical
Data table and Motor Limitations table can be utilized with
extreme confidence. Using Carrier motors with the values
listed in the Physical Data and Motor Limitations tables will
not result in nuisance tripping or premature motor failure.
The unit warranty will not be affected.
Electric heat A field-supplied 90-degree elbow must

on heating.

be installed in the supply ductwork below the unit


discharge.

Maximum airflow To minimize the possibility of

Auxiliary coil The 48/50P units with extended

condensate blow-off from evaporator, airflow through units


should not exceed values shown in the Unit Design Airflow
Limits table on page 7 and Cooling Capacities tables.

Minimum airflow The minimum airflow for cooling


is 300 cfm/ton for constant volume units and 70 cfm/ton
for VAV (variable air volume) units. Performance at
70 cfm/ton is limited to unloaded operation and may be
additionally limited by entering-air temperatures. Refer to
Gas Heating Capacities tables on pages 7-12 for minimum
airflow cfm for heating.

Minimum ambient cooling operation temperature All units are equipped with factory economizers
to allow free cooling at any outdoor ambient. If mechanical
cooling is required, the units are designed to operate at
outdoor temperatures down to 32 F. With accessory Motormaster V control units can operate at outdoor temperatures down to 20 F. Outdoor-fan motor change out may
be required for Motormaster V applications.
Carrier recommends the installation of field-fabricated
wind baffles on all vertically oriented condenser coil surfaces when operating in environments with prevailing winds
of more than 5 mph and where temperatures drop below
32 F.

Maximum operating outdoor-air temperature


The maximum operating outdoor-air temperature is
115 F. Some models will operate up to 125 F depending
on model and operating conditions.

138

chassis are capable of accepting field-supplied and installed


auxiliary coils (typically hydronic heating, steam heating, or
refrigeration heat reclaim coils). These units include coil
tracks and face framing to facilitate installation of auxiliary
coils. See the figure on next page for dimensions on coil
tract locations inside these units. See the Auxiliary Coil
Frame Dimension table for dimensions for the auxiliary
coil.
AUXILIARY COIL FRAME DIMENSIONS (in.)
UNIT SIZE 48/50P
Casing Depth
Casing Height
Casing Length*
Overall Length

030-050

055-100

9.80
55.52
69.50
83.90

9.80
66.00
69.50
83.90

*Longer casing lengths possible but modifications to face framing sheet


metal will be required during installation.
Represents the maximum overall length of the coil plus all piping and
coil control devices located inside the air handler cabinet.

Application of hydronic coils and steam heating coils in


outdoor located equipment should always be considered
very carefully. Design such systems for low temperature
protection in the event of power failure to the unit.
Steam coils are typically not recommended for installation
in outdoor located equipment, due to added space required
for fluid control and need to protect all piping and controls
in the event of power failure to the building and/or the
unit. Consider installing small steam-to-hydronic heat exchangers with circulating pump to deliver hydronic fluids
out to the auxiliary coil in the air conditioner unit.

LOCATION OF COIL TRACKS

B
A

AUXILIARY COIL LOCATION in.


UNIT
SIZES 48/50P
030,035
040,050
055-070
075-100
075-100 with HighCapacity Power Exhaust

DISTANCE A HEIGHT B
123.0
156.8
200.4
200.4

6.6
6.6
6.6
6.6

279.2

6.6

139

Typical piping and wiring


STANDARD UNITS (48P2100 SHOWN)
ECONOMIZER
HOODS

a48-8438

POWER
EXHAUST

PRIMARY
CONDENSATE
DRAIN (TO
SERVICE
DRAIN)
RETURN
AIR

140

CONTROL BOX
ACCESS PANELS

AUXILIARY
CONDENSATE
DRAIN
(BOTH SIDES)
NATURAL GAS
SUPPLY LINE
(WITH SHUTOFF
VALVE 48P ONLY)

FIELDINSTALLED
SERVICE
DISCONNECT
SUPPLY
AIR

POWER
SUPPLY

POWER SCHEMATIC SIZES 040-075 SHOWN

Typical wiring schematics


a48-8439

141

Typical wiring schematics (cont)


INPUT/OUTPUT DIAGRAM MAIN BASE BOARD

a48-8440

142

INPUT/OUTPUT DIAGRAM RXB, EXB, CEM, SCB


RXB

a48-8441

EXB

143

Typical wiring schematics (cont)


CONTROL SECTION 48P2,P3,P4,P5 UNITS

a48-8442

144

CONTROL SECTION 50P2,P3,P4,P5 UNITS

a50-8378

145

Typical wiring schematics (cont)


115-VOLT WIRING

a48-8443

146

LEGEND FOR TYPICAL CONTROL WIRING SCHEMATICS


ACCSY
ACCY
AF
AN
APS
AUX
C
CAP
CB
CCB
CCH
CCN
CCT
CEM
CMR
COMP
CSB
CXB
DGS
DI
DPT
DUS
ECB
ECON
EQUIP
EVAP
EXB
EXH
EXV
FU
GND

Accessory
Accessory
Air Foil
Analog
Air Pressure Switch
Auxiliary
Compressor Contactor
Capacity
Compressor Circuit Breaker
Control Circuit Breaker
Crankcase Heater
Carrier Comfort Network
Cooling Coil Thermistor
Controls Expansion Module
Compressor Modulation Relay
Compressor
Current Sensor Board
Compressor Expansion Board
Digital Scroll Compressor
Digital Input
Discharge Pressure Transducer
Digital Unloader Solenoid
Economizer Control Board
Economizer
Equipment
Evaporator
Economizer Control Board
Exhaust
Expansion Valve Control Board
Fuse
Ground

HC
HIR
HMV
HPS
HVS
IAQ
IFC
IFCB
IFM
IGC
LEN
LLS
MBB
MGV
MLV
MP
OA
OAT
OD
OFC
OFM
OPT
PE
PEC
PECB
PEM
PL
PP
PTC

Heater Contactor
Heat Interlock Relay
Humidi-MiZer Modulating Valve
High-Pressure Switch
Humidi-MiZer Valve Solenoid
Indoor Air Quality
Indoor Fan Contactor
Indoor Fan Circuit Breaker
Indoor Fan Motor
Integrated Gas Controller
Local Equipment Network
Liquid Line Solenoid
Main Base Board
Main Gas Valve
Minimum Load Valve
Modular Motor Protector
Outdoor Air
Outdoor-Air Thermistor
Outdoor
Outdoor Fan Contactor
Outdoor Fan Motor
Option
Power Exhaust
Power Exhaust Contactor
Power Exhaust Circuit Breaker
Power Exhaust Motor
Plug Assembly
Plenum Pressure
Positive Temperature Coefficient
Power Reference

RA
RAT
RCB
RET
RF
RXB
SAT
SCB
SPT
STDU
TB
TRAN
UPC
VAV
VFD

Return Air
Return Air Thermistor
Rooftop Control Board
Return
Return Fan
Rooftop Control Board
Supply Air Thermistor
Staged Gas Control Board
Suction Pressure Transducer
Standard Tier Display Unit
Terminal Block
Transformer
Unitary Protocol Converter
Variable Air Volume
Variable Frequency Drive
Terminal Block
Terminal (Unmarked)
Terminal (Marked)
Splice
Factory Wiring
Field Wiring
To indicate common potential
only, not to represent wiring.
To indicate FIOP or Accessory

147

Guide specifications 48P2,P3,P4,P5 units


Packaged Rooftop Cooling Unit with Gas
Heat and ComfortLink Controls
HVAC Guide Specifications
Section 48P2,P3,P4,P5
Size Range: 30 to 100 Tons, Nominal
Carrier Model Number:
48P2 (Vertical Supply/Return,
Constant Volume [CV] Application, Staged Air
Volume [SAV])
48P3 (Vertical Supply/Return,
Variable Air Volume [VAV] Application)
48P4 (Horizontal Supply/Return,
Constant Volume Application, Staged Air
Volume [SAV])
48P5 (Horizontal Supply/Return,
Variable Air Volume Application)
Part 1 General
1.01 SYSTEM DESCRIPTION
Outdoor, roof-curb mounted, electronically controlled heating and cooling unit utilizing hermetic
scroll compressors with crankcase heaters for cooling duty and gas combustion for heating duty. Units
shall supply and return air vertically or horizontally
as shown on the contract drawings.
1.02 QUALITY ASSURANCE
A. Unit shall be rated in accordance with AHRI Standard 340/360, latest edition.
B. Unit shall be designed to conform to ANSI/
ASHRAE 15 (latest edition), ASHRAE 62, and UL
Standard 1995.
C. Unit shall be listed by ETL and ETL, Canada, as a
total package.
D. Unit shall be designed to conform to ANSI Standard
Z21.47 (U.S.A.)/CSA Standard 2.3 (Canada), GasFired Central Furnaces.
E. Roof curb shall be designed to NRCA criteria per
Guideline B-1986.
F. Insulation and adhesive shall meet NFPA 90A
requirements for flame spread and smoke
generation.
1.03 DELIVERY, STORAGE, AND HANDLING
Unit shall be stored and handled per manufacturers
recommendations.
Part 2 Products
2.01 EQUIPMENT
A. Factory-assembled, single-piece heating and cooling
unit. Contained within the unit enclosure shall be all
factory wiring, piping, refrigerant charge (R-410A),
operating oil charge, dual refrigerant circuits, microprocessor-based control system and associated hardware, and all special features required prior to field
start-up.
B. Unit Cabinet:
1. Constructed of galvanized steel (designated G90
per ASTM Standard A653 minimum coating
148

weight of 0.9 oz of zinc per square foot),


bonderized and primer-coated on both sides
and coated with a baked polyester thermosetting powdercoating finish on the outer surface.
2. Unit casing shall be capable of withstanding
ASTM Standard B117 500-hour salt spray test.
3. Sides shall have man size insulated, double
wall, hinged access doors for easy access to the
control box and other areas requiring servicing.
Each door shall seal against a rubber gasket to
prevent air and water leakage.
4. Interior cabinet surfaces (except heat exchanger
section) shall be insulated with flexible fireretardant dual-density (1.75-lb/cu ft) fiberglass
blanket, coated on the air side. Insulation coating shall be cleanable and shall contain an EPAregistered immobilized antimicrobial agent to
effectively resist the growth of bacteria and
fungi as proven by tests in accordance with
ASTM Standards G21 and G22.
5. Interior cabinet surfaces within heat exchanger
section shall be lined with sheet metal on all
surfaces, insulated on the side opposite the
airstream.
6. Insulation shall be applied by means of adhesion using a water reducible adhesive sprayed
onto interior surface. Adhesive shall maintain a
satisfactory adhesion and cohesion within the
temperature range of 20 to 180 F and have
excellent resistance to water and water vapor
when cured.
7. Unit shall contain a sloped drain pan, to prevent standing water from accumulating. Pan
shall be fabricated of stainless steel. Unit shall
contain a factory-installed nonferrous main condensate drain connection.
8. Units shall be equipped with lifting lugs to facilitate overhead rigging.
C. Fans:
1. Supply Fan:
a. Unit shall have only one fan wheel, scroll,
and motor.
b. Fan scroll, wheel, shaft, bearings, drive components and motor shall be mounted on a
formed steel assembly which shall be isolated from the unit outer casing with factoryinstalled 2-in. deflection spring isolators and
vibration-absorbent fan discharge seal.
c. Fan shall be double-width, double-inlet, centrifugal belt driven forward-curve type with
single outlet discharge (standard) or centrifugal belt driven airfoil blade section type with
single outlet discharge (optional).
d. Fan wheel shall be designed for continuous
operation at the maximum rated fan speed
and motor horsepower.
e. Fan wheel and shaft shall be selected to
operate at 25% below the first critical speed

and shall be statically and dynamically balanced as an assembly.


f. Fan shaft shall be solid steel, turned, ground
and polished, and coated with rust preventative oil.
g. Fan shaft bearings shall be self-aligning, pillow-block, regreasable ball or roller-type
selected for a minimum average life of
200,000 hours at design operating conditions in accordance with ANSI B3.15.
h. A single motor shall be mounted within the
fan section casing on slide rails equipped
with adjusting screws. Motor shall be
mounted on a horizontal flat surface and
shall not be supported by the fan or its structural members.
i. Fan drive shall be constant-speed fixed-pitch.
All drives shall be factory-mounted, with
belts aligned and tensioned.
2. Condenser Fans:
a. Direct-driven propeller type.
b. Size 035 units shall have a direct driven, 11blade airfoil cross section, reinforced polymer construction, and shrouded-axial type
fans with inherent corrosion resistance.
c. Discharge air vertically upward.
d. Protected by PVC-coated steel wire safety
guards.
e. Statically and dynamically balanced.
f. Three-phase, totally enclosed motors.
D. Compressors:
1. Fully hermetic scroll type compressors with
overload protection and short cycle protection
with minimum on and off timers.
2. Factory rubber-in-shear mounted for vibration
isolation.
3. Reverse rotation protection capability.
4. Crankcase heaters shall only be activated during
compressor off mode.
E. Coils:
1. Evaporator Coil:
a. Intertwined circuiting constructed of aluminum fins mechanically bonded to seamless
copper tubes.
b. Full-face active type during full and part load
conditions.
c. Coils shall be leak tested at 150 psig and
pressure tested at 650 psig.
2. Condenser Coils:
a. Condenser coils shall be microchannel
design. The coils shall have a series of flat
tubes containing a series of multiple, parallel
flow microchannels layered between the
refrigerant manifolds. Microchannel coils
shall consist of a two-pass arrangement. Coil

F.

G.

H.

I.

construction shall consist of aluminum alloys


for the fins, tubes and manifolds.
b. Air-cooled condenser coils shall be leak
tested at 150 psig and pressure tested at
650 psig.
Outdoor-Air Hood Assembly:
Factory-installed manual outdoor-air damper shall
allow intake of up to 25% nominal airflow (on units
not equipped with optional economizer).
Heating Section:
1. Induced-draft combustion type with energy saving direct spark ignition systems and redundant
main gas valves.
2. The heat exchanger shall be of the tubular section type constructed of a minimum of 20-gage
steel coated with a nominal 1.4 mil aluminumsilicone alloy for corrosion resistance.
Optional construction:
Heat exchanger shall be constructed of minimum 20-gage Type 409 Stainless Steel for corrosion resistance. Tubing material shall be
suited for high temperature and corrosion
resisting service. Tubing material shall comply
with ASTM A268, Grade TP409. Tubing shall
be welded and annealed.
3. Burners shall be of the in-shot type constructed
of aluminized steel.
4. Induced Draft Fans:
a. Direct-driven, single inlet, forward-curved
centrifugal type.
b. Statically and dynamically balanced.
c. Made from steel with a corrosion-resistant
finish.
5. High-corrosion areas such as flue gas collection
and exhaust areas shall be lined with corrosionresistant material.
6. All gas piping shall enter the unit cabinet at a
single location.
Refrigerant Components:
Unit shall be equipped with dual refrigerant circuits,
each containing:
1. Filter drier.
2. Moisture indicating sight glass.
3. Thermostatic expansion valve.
4. Fusible plug.
Filter Section:
1. Filter section shall consist of 2-in. thick,
MERV 7 disposable fiberglass filters of commercially available sizes.
2. Factory 2-in. filter track shall allow easy field
conversion to accept 4-in. thick, disposable
fiberglass filters of commercially available sizes.

149

Guide specifications 48P2,P3,P4,P5 units (cont)


J. Controls, Safeties, and Diagnostics:
1. Controls:
a. Control shall be accomplished through the
use of a factory-installed, microprocessorbased control system and associated electronic and electrical hardware. Control
system shall determine control sequences
through monitoring the following operational variables:
1) Day and Time.
2) Schedule (Unoccupied/Occupied).
3) Set points (Unoccupied/Occupied,
Economizer, Duct Pressure, others).
4) Space temperature.
5) Outdoor air temperature.
6) Unit supply air temperature.
7) Unit return air temperature.
8) Supply-air fan status.
9) Economizer position.
10) Compressor suction and discharge
pressure.
11) Scrolling marquee display.
12) Accessory and/or field-supplied sensors,
function switches and/or signals.
b. Controls shall be capable of performing the
following functions:
1) Capacity control based on supply-air
temperature and compensated by rate
of change of return-air temperature
(VAV) or room temperature (CV).
Capacity control shall be accomplished
through the use of compressor staging
or optional variable output compressors.
2) Perform a quick test to check the status
of all input and output signals to the
control system using scrolling marquee
or Navigator display.
3) Control of integrated economizer
operation, based on unit supply-air
temperature.
4) Supply fan volume control shall control
output from a variable frequency drive to
maintain duct static pressure at userconfigured set point (VAV). Static pressure reset in conjunction with Carrier
communicating terminals to reduce supply fan power requirements. Control
system calculates the amount of supply
static pressure reduction necessary to
cause the most open damper in the system to open more than the minimum
value (60%) but not more than the maximum value (90% or negligible static
pressure drop).
5) Heating control shall provide space temperature control for unoccupied period
heating, morning warm-up sequence
and occupied period heating (when
configured).

150

6) Adaptive optimal start shall determine


the time unit will commence cooling (or
heating or heating for morning warmup) during the unoccupied mode to
ensure occupied space reaches the set
point in time for occupied mode.
7) Adaptive optimal stop shall turn off the
compressors a preset amount of time
before the end of the occupied mode to
conserve energy (CV only).
8) Alerts and Alarms: Control shall continuously monitor all sensor inputs and
control outputs to ensure safe and
proper system operation. Alerts shall be
generated whenever sensor conditions
have gone outside criteria for acceptability. Alarms shall be initiated when unit
control detects that a sensor input value
is outside its valid range (indicating a
defective device or connection that prevents full unit operation) or that an output has not functioned as expected or
that a safety device has tripped. Current
alarms shall be maintained in STATUS
function; up to 9 (current or reset) shall
be stored in HISTORY function for
recall.
9) Timed override function shall permit a
system in unoccupied mode to be
returned to occupied mode for a userconfigured period of 1, 2, 3 or 4 hours
by pressing the override button on the
front of the space temperature sensor.
10) Nighttime Free Cooling (NTFC) shall
start the supply fan and open the economizer on cool nights to precool the
building structure mass using only outdoor air. Function shall be restricted to
operation above a user-configured low
lockout temperature set point.
11) Modulating power exhaust control shall
modulate capacity of exhaust fan system
in response to building static pressure
at user-configured set point. Power
exhaust fan operation shall be interlocked with supply fan operation.
12) Return fan control (on optional return
fan equipped units only) shall measure
supply fan CFM and modulate return
fan to maintain constant CFM differential between supply and return fan.
Return fan operation shall be interlocked with supply fan operation.
Capacity of exhaust air shall modulate in
response to building static pressure at
user-configured set point.
13) Smoke control functions: Control shall
initiate any of four separate smoke control functions in response to closure of
field switches. Functions shall include:
Pressurization,
Evacuation,
Smoke
Purge and Fire Shutdown. Should two

14)

15)

16)
17)

18)

19)

20)

21)

or more switches be closed simultaneously, Fire Shutdown shall be initiated.


Support demand controlled ventilation
through a reset of the economizer's minimum position. This reset based on differential CO2 ppm (outdoor and indoor)
can be chosen as linear or as fast or
slow-acting exponential curves.
Indoor air quality (IAQ) mode shall admit
fresh outdoor air into the space whenever space air quality sensors detect
unsuitable space conditions, by overriding economizer minimum damper position. IAQ shall be permitted only during
occupied periods, unless configured to
be allowed during unoccupied periods
also.
Provide control for reheat via auxiliary
heating coil or gas heat during ventilation.
IAQ pre-occupancy purge function shall
provide complete exchange of indoor air
with fresh air during unoccupied periods, when outdoor conditions permit.
Function shall energize supply fan and
open economizer two hours before next
occupied period; duration of purge shall
be user-configured (5 to 60 minutes).
Outdoor Air Control (OAC) function
shall maintain a minimum quantity of
outdoor airflow into an occupied space.
OAC mode shall be available only during
an occupied period. Outdoor airflow
shall be monitored by an airflow station
and transducer. Economizer maximum
damper opening position during OAC
mode shall be user-configured.
Dehumidification and Reheat: Dehumidification function shall override comfort
condition set points to deliver cooler air
into the space and satisfy a userconfigured humidity set point at the
space or return air humidity sensor.
Reheat function shall energize an auxiliary heating device should dehumidification operation result in cooling of the
space down to the occupied heating set
point.
Supply Air Temperature Set Point
Reset: Control shall automatically reset
the unit supply air temperature set point
on VAV models from either space temperature or return-air temperature, at
user-configured rate and limit. Control
shall also reset supply air temperature
set point via external 2 to 10 vdc signal
representing 0 to 20 F range of reset.
Control shall respond to higher of either
reset if both are active.
Space Temperature Offset function shall
permit occupants to adjust space
temperature set point by 5 F using

T-56 space sensor (equipped with sliding scale adjuster).


22) Lead-lag function shall distribute starts
between the two refrigeration circuits in
an effort to equalize the running time on
the two circuits.
23) Condenser-fan cycling control shall
maintain correct head pressure down to
0 F.
24) Refrigeration system pressures shall be
monitored via pressure transducers.
Alarms for low pressure, high pressure
will be permitted.
25) Timed Discrete Output function shall
control an external function or device
via user-configured activity schedule.
This schedule shall be separate and different from the units occupied/unoccupied time schedule.
26) Humidifier control shall provide control
for either LEN (local equipment network) communicating control valve or
discrete-type output, to maintain space
humidity conditions at user-configured
set points.
27) Two-step demand limit control (when
used in conjunction with CEM [controls
expansion module]).
28) Display in Metric units: Display may be
configured to display data in Metric or
English (Imperial) units of measure.
2. Safeties:
Unit components shall be equipped with the following protections:
a. Compressors:
1) Overcurrent using calibrated circuit
breakers
(shuts
down
individual
compressor).
2) Crankcase heaters.
3) High-pressure switch (shuts down individual circuit, automatic reset type).
4) Low-pressure switch (shuts down individual circuit, automatic reset type).
5) Check filter switch.
b. Belt-Drive Fan Motors:
Overcurrent protection manual reset circuit
breakers.
c. Heating Section:
1) Redundant gas valves.
2) Flame proving controls.
3) Induced-draft fan motor speed sensor.
4) High-temperature limit switch.
5) Flame rollout switch.
3. Diagnostics:
a. The display shall be capable of indicating a
safety lockout condition (alarm) through an
expandable scrolling display.
b. The display shall also be capable of indicating an alert condition which does not lock
151

Guide specifications 48P2,P3,P4,P5 units (cont)

K.

L.

M.

N.

152

out the unit, but informs the system monitor


of a condition which could be detrimental to
either the unit or the comfort of the occupants if allowed to continue.
c. Test mode must also be capable of displaying outputs of microprocessor-controller and
to verify operation of every thermistor, actuator motor, fan, and compressor before unit
is started.
Operating Characteristics:
1. Unit shall be capable of starting and running at
115 F ambient outdoor temperature per maximum load criteria of AHRI Standard 340/360,
latest edition.
2. Unit shall be capable of mechanical cooling
operation down to 32 F ambient outdoor
temperature (20 F with low ambient
accessory).
3. Provides multi-stage cooling capability.
4. Provides 2 stages of heating capability.
Motors:
1. Compressor motors shall be cooled by suction
gas passing over motor windings.
2. Condenser-fan motors shall be 3-phase, totally
enclosed type with permanently lubricated
ball bearings and internal over-temperature
protection.
3. Supply and exhaust fan motors shall be of the
3-phase, NEMA rated, open drip-proof (ODP),
ball bearing type, with efficiencies per EISA of
2007 (U.S.A.) requirements.
Electrical Requirements:
All unit power wiring shall enter unit cabinet at a single location.
Special Features:
1. Digital Compressor:
A digital compressor shall be available on the
lead circuit for constant volume and variable air
volume configurations. The ComfortLink control system shall be capable of unloading this
compressor in an infinite number of steps from
100% of unit capacity down to 50% of compressor capacity.
2. Humidi-MiZer Adaptive Dehumidification:
The Humidi-MiZer dehumidification system
shall be factory installed and shall provide
greater dehumidification of the occupied space
by using two modes of dehumidification instead
of the normal design cooling mode of the unit:
a. Subcooling mode shall further sub-cool the
hot liquid refrigerant leaving the condenser
coil when both temperature and humidity in
the space are not satisfied.
b. Hot gas reheat mode shall mix a portion of
the hot gas from the discharge of the compressor with the hot liquid refrigerant leaving

the condenser coil to create a two-phase


heat transfer in the system, resulting in a
neutral leaving-air temperature.
c. The system shall be equipped with modulating control valves to provide precise leavingair temperature control. On-off, cycling type
control shall not be acceptable.
3. Integrated Economizer:
Dry bulb, differential dry bulb temperature,
enthalpy, or optional differential enthalpy controlled integrated type consisting of dampers,
actuator, and linkages in conjunction with control system to provide primary cooling using
outdoor air, enthalpy permitting, supplemented with mechanical cooling when necessary.
a. Economizer shall meet the requirements of
the California Energy commission airside
economizer acceptance test.
b. Dampers shall be a gear driven low-leakage
type.
c. Actuator shall have a spring-return feature
which shuts dampers upon a power interruption or unit shutdown. Actuators are capable
of internal diagnostics.
d. Equipped with a solid-state humidity sensor
that is capable of sensing outdoor-air heat
content (temperature and humidity) and controlling economizer cut-in point at most economical level. The user can also configure
dew point limiting.
4. Ultra Low Leak Economizer:
Dry bulb, differential dry bulb temperature,
enthalpy, or optional differential enthalpy controlled integrated type consisting of dampers,
actuator, and linkages in conjunction with control system to provide primary cooling using
outdoor air, enthalpy permitting, supplemented with mechanical cooling when necessary.
a. Economizer shall meet the requirements of
the California Energy commission airside
economizer acceptance test.
b. Dampers shall be a gear driven ultra lowleakage type with blade and edge seals.
Dampers shall exhibit a maximum leakage
rate of 4 cfm per square foot of area at
1 in. wg pressure differential when tested in
accordance with AMCA Standard 500.
c. Actuator shall have a spring-return feature
which shuts dampers upon a power interruption or unit shutdown. Actuators are capable
of internal diagnostics.
d. Equipped with a solid-state humidity sensor
that is capable of sensing outdoor-air heat
content (temperature and humidity) and controlling economizer cut-in point at most

economical level. The user can also configure dew point limiting.
5. Modulating Power Exhaust with VFD:
Package shall include 2 double-width, doubleinlet centrifugal belt drive, forward-curved
power exhaust fans with variable frequency
drive control of each fan to maintain a field
adjustable interior space pressure set point.
a. Fan bearings shall be of the pillow block
type with an average design life of
200,000 hours.
b. Fans shall be statically and dynamically
balanced.
c. Bypass for the VFD shall be available as a
factory-installed option.
6. High-Capacity Modulating Power Exhaust System (75 to 100 ton units only):
High-capacity modulating power exhaust system shall be factory-installed and contain fans
and motors, exhaust hoods and controls (including variable frequency drive and staging
sequence) to maintain space pressure at userconfigured set point.
a. Dual fan assemblies with individual motors.
b. Variable frequency drive for modulating
capacity of lead fan.
c. Staged control on lag fan.
d. Differential pressure transducer for monitoring space pressure.
e. Exhaust air hood assemblies containing
backdraft dampers on each fan outlet, factory installed.
f. All wiring and pressure tubing (except to
space pressure pickup location) shall be factory supplied and installed.
7. Return Fan/Building Pressure Control (75 to
100 ton units only):
a. Functions provided shall be:
1) Airflow control for return duct path
(dedicated to overcoming flow losses in
return duct system).
2) Modulate return airflow rate to track
supply fan airflow rate and maintain a
user set delta cfm between the supply
and return airflow.
3) Maintain building pressure by sensing
building pressure and modulating fan
speed.
b. Option shall consist of following hardware:
1) Plenum fan assembly, with welded steel
airfoil blade fan.
2) Spring isolation.
3) Belt-drive fan system, fixed pitch for
maximum belt life and reliability.
4) Variable frequency drive (VFD) for
return fan modulation control.

8.

9.

10.

11.

12.

13.

5) Supply air CFM and return air CFM sensors to measure supply and return airflow.
6) Exhaust damper with outlet hood.
7) Building pressure transducer.
c. Installation:
1) Site installation shall require supply and
installation of building pressure (BP)
sensing pick-up and tube to connect to
BP transducer in unit.
2) All other wiring and pressure tubing
shall be factory-supplied and factory
installed.
Barometric Relief Package:
a. Package shall relieve excess internal pressure and consist of damper assemblies,
hoods, damper screens, seal strips and
required hardware.
b. Damper assemblies shall close due to gravity
upon unit shutoff.
Pleated Filters:
Unit shall be factory equipped with MERV 7
pleated filters having the following characteristics:
a. Efficiency of no less than 30% based on testing per ASHRAE Standard 52.
b. Minimum average arrestance of 95%.
High-Efficiency Pleated Filters (75 to 100 ton
units only):
Unit shall be factory equipped with MERV 11
high-efficiency pleated filters having the following characteristics:
a. Filters shall have a design dust spot efficiency with an average of 60 to 65% based
on the ASHRAE Standard 52.1 test
method.
b. Filters shall have a minimum arrestance of
90%.
c. Filters shall be classified as a Class 2 air filter
according to UL Standard 900.
Bag Filters with Prefilters (30 to 70 ton units
only):
Unit shall be factory equipped with MERV 15
bag filters and 2-in. prefilters, and shall have an
average efficiency of 90% based on testing per
ASHRAE Standard 52.
Cartridge Filters with Prefilters (30 to 70 ton
units only):
Unit shall be factory equipped with cartridge filter mounting system with 2-in. prefilters.
Supply Fan Variable Frequency Drive:
Variable air volume and staged air volume units
shall be equipped with variable frequency drive
(VFD) inverter. The VFD shall be provided with
a metal enclosure and shall be factory-mounted,

153

Guide specifications 48P2,P3,P4,P5 units (cont)


wired, and tested. The variable speed drive shall
include the following features:
a. Full digital control with direct control from
the unit ComfortLink controls.
b. Insulated gate bi-polar transistors (IGBT)
used to produce the output pulse width modulated (PWM) waveform, allowing for quiet
motor operation.
c. Inverters capable of operation at a frequency
of 8 kHz so no acoustic noise shall be produced by the motor.
d. Metal enclosure for reduction of RFI (radio
frequency interference).
e. Digital display keypad module, mounted on
the VFD enclosure.
f. Local/Remote and Manual/Auto function
keys on the keypad.
g. UL-listed electronic overload protection.
h. Critical frequency avoidance.
i. Self diagnostics.
j. On-board storage of unit manufacturer's customer user settings, retrievable from the keypad.
k. RS485 communications capability (accessory card source required).
l. Internal thermal overload protection.
m. 5% swinging chokes for harmonic reduction
and improved power factor.
n. All printed circuit boards shall be conformal
coated.
14. Supply Fan Static Pressure Control (VAV units):
Variable air volume units shall be equipped with
a supply fan VFD. The VFD shall control
motor speed to maintain set point static pressure control at the supply duct sensor tube location. The supply fan drive shall be fieldadjustable to maintain supply duct static pressure set point from 0.0-in. wg to 5-in. wg,
adjusted via scrolling marquee display or Navigator display. A pressure transducer shall be
factory-mounted and wired. (Control tubing
from sensor tube location to transducer shall be
field-supplied and installed.) Transducer shall
provide a 4 to 20 mA signal to the unit control
module; unit control module shall provide a 4 to
20 mA signal to the VFD indicating desired
VFD output level.
15. Staged Air Volume (SAV) Units:
Staged air volume units shall be equipped with a
supply fan VFD. The VFD shall control motor
speed to user configurable speeds. High speed
shall be a percentage of 60 Hz, and shall be
user configurable. The range of adjustment for
high speed shall be between 50 and 100% of
60 Hz. Low speed shall be a percentage of
60 Hz, and shall be user configurable. The
range of adjustment for low speed shall be
154

between 33 and 67% of 60 Hz. The control


shall allow user configurable fan speeds for
cooling and heating modes.
16. Staged Gas Control:
a. Staged gas control option shall monitor unit
supply-air temperature and sequence the
unit heat exchanger staging to provide the
following sequences:
1) Tempering heat control, based on userconfigured ventilation supply air temperature set point, to eliminate cold
draft conditions with low mixed-air
temperatures.
2) First-stage demand heating control, with
staging selected to maintain userconfigured heating supply air temperature set point.
3) Full-fire demand heating on heating control command.
b. Staged gas control option shall consist of:
1) Supply air temperature thermistors with
duct-mounting base.
2) Limit switch temperature thermistor.
3) Stainless steel heat exchanger tubes and
construction option.
c. Field installation shall be limited to installing
three supply air temperature thermistors in
the supply duct. All other hardware, wiring
and piping shall be factory-completed.
17. Modulating Gas Heat:
a. Modulating gas heat option shall monitor
unit supply-air temperature and control the
unit heat exchanger to provide the following
sequences:
1) First-stage demand heating control, with
modulation to maintain user-configured
heating supply air temperature set point.
Turndown ratio to be at least 4:1
(325 MBtuh), 7:1 (650 MBtuh) and
11:1 (975 MBtuh).
2) Full-fire demand heating on heating control command.
3) Tempering heat control, based on userconfigured ventilation supply air temperature set point, to eliminate cold draft
conditions with low mixed-air temperatures.
b. Modulating gas control option shall consist
of:
1) Modulating controller capable of ensuring the proper fuel air mixture at operating firing rates.
2) Supply air temperature thermistors with
duct-mounting base.
3) Limit switch temperature thermistor.
4) Stainless steel heat exchanger tubes.
c. Field installation shall be limited to installing
three supply air temperature thermistors in

18.

19.

20.

21.

22.

23.

the supply duct. All other hardware, wiring


and piping shall be factory-completed.
LP (Liquid Propane) Conversion Kit (30 to 70
ton units only):
Provides all necessary hardware and labels for
conversion from natural gas to LP gas. (Not for
use with staged gas control option.)
Extended Chassis:
Extended chassis designs shall contain an added
length module, after the evaporator section, as
shown in the contract drawings. Module shall
contain tracks to accept field-supplied/installed
auxiliary heating coil.
Non-Fused Disconnect:
A non-fused electrical disconnect for main unit
power shall be factory installed. The disconnect
shall be an interlocking through-the-door type.
115-Volt Convenience Outlet:
A duplex GFCI (ground fault circuit interrupt)
receptacle shall be factory mounted in a weatherproof enclosure and wired for a 10-amp load.
It will remain powered when all unit circuit
breakers have been turned off. The outlet will
be deenergized by the unit disconnect.
Navigator Display Module:
The Navigator display module shall be a portable hand-held display module with a minimum
of 4 lines and 20 characters per line, of clear
English, Spanish, Portuguese or French language. Display menus shall provide clear
language descriptions of all menu items, operating modes, configuration points and alarm
diagnostics. Reference to factory codes shall
not be accepted. An industrial grade coiled
extension cord shall allow the display module to
be moved around the chiller. Magnets shall hold
the display module to any sheet metal panel to
allow hands-free operation. Display module
shall have NEMA 4x housing suitable for use in
outdoor environments. Display shall have back
light and contrast adjustment for easy viewing
in bright sunlight or night conditions. The display module shall have raised surface buttons
with positive tactile response.
Controls Expansion Module (CEM):
Factory-installed package shall include all
hardware for additional control of base unit
operation and product integrated controls features. The functions supported are:
a. Building pressurization, evacuation, and
smoke purge control.
b. Supply air reset from external 4 to 20 mA
signal.
c. Two-step demand limit inputs (when used
with the CCN network).
d. Indoor air quality (IAQ) switch monitoring.
e. Outdoor airflow monitoring

24.

25.

26.

27.

28.

29.

30.

f. Outdoor humidity monitoring.


g. Space humidity monitoring (required for
dehumidification control, reheat and humidifier control).
h. Return air humidity monitoring.
i. Demand limiting from an external 4 to
20 mA signal.
j. Static pressure reset from an external 4 to
20 mA signal.
Relative Humidity Sensors:
Package shall contain either duct-mounted or
wall-mounted sensors to measure the relative
humidity of the air within the occupied space
(specify location) or return duct and/or outside
air.
NOTE: For relative humidity sensor monitoring,
the CEM must also be ordered.
Indoor Air Quality (CO2) Sensor:
a. Shall have the ability to provide demand ventilation indoor-air quality (IAQ) control
through the economizer with an indoor air
quality sensor.
b. The IAQ sensor shall be available in duct
mount, wall mount, and wall mount with
LED display of CO2 in parts per million. The
set point shall have adjustment capability.
Return Air Smoke Detector:
The smoke detector shall send input to the controller to shut down the unit in case smoke is
detected.
Outdoor Airflow Sensor:
Outdoor airflow sensor package shall contain a
airflow station with airflow sensor, a transducer
and all hardware required to measure the quantity of outdoor air brought in through the economizer dampers. Optional economizer and
CEM are required with this accessory.
Differential Enthalpy Switch or Sensors (when
equipped with both return air and outdoor air
humidity sensors):
a. For use with economizer only.
b. Capable of comparing heat content (temperature and humidity) of outdoor and return air
and controlling economizer cut-in point at
the most economical level.
Hot Gas Bypass:
Unit shall be factory equipped with hot gas
bypass valve, and tubing to maintain capacity
control at minimal cooling loads.
Condenser Coil Protective Coating E-Coated
Microchannel Coil:
E-coated aluminum microchannel coils shall
have a flexible epoxy polymer coating uniformly applied to all coil external surface areas
without material bridging between fins or louvers. Coating process shall ensure complete coil
155

Guide specifications 48P2,P3,P4,P5 units (cont)

31.

32.

33.

34.

35.

36.

156

encapsulation, including all exposed fin edges.


E-coat thickness of 0.8 to 1.2 mil with top coat
having a uniform dry thickness from 1.0 to 2.0
mil on all external coil surface areas, including
fin edges, shall be provided. E-coated coils shall
have superior hardness characteristics of 2H
per ASTM D3363-00 and cross-hatch adhesion
of 4B-5B per ASTM D3359-02. E-coated coils
shall have superior impact resistance with no
cracking, chipping, or peeling per NSF/ANSI
51-2002 Method 10.2.
Condenser Coil Hail Guard (sizes 030 to 060
only):
Canted face enclosure and welded wire grille
complete with support retainers and fasteners
shall be provided for protection of condenser
coils. Field-assembled.
BACnet Communication Option:
Shall provide factory-installed communication
capability with a BACnet MS/TP network.
Allows integration with i-Vu Open control system or a BACnet Building Automation System.
MODBUS Protocol Translator:
A controller-based accessory module shall provide CCN access to MODBUS Remote Terminal Unit (RTU) protocol conversion.
LonWorks Protocol Translator:
A controller-based accessory module shall provide CCN access to LON FT-10A ANSI/EIA709.1 protocol conversion.
Space Temperature Sensor (T-56):
The T-56 space temperature sensor (for CV
applications) shall monitor space temperature.
Device shall be suited for wall mounting in the
occupied space. The T-56 sensor shall incorporate a front-panel located slider switch to effect
a remote change in set point of 5 F. The
T-56 sensor shall also include a button used to
initiate Unoccupied Override function.
Space Temperature Sensor (T-56) with CO2
Sensor:
This device shall incorporate interior space temperature sensing and interior space CO2 level
monitoring functions. Space temperature sensor shall sense the actual temperature in the
conditioned space via 10,000-ohm thermistor.
Temperature set point adjustment potentiometer via slide scale shall provide 5 F adjustment. The CO2 sensor shall provide CO2
measurement range of 0 to 2000 ppm. IAQ
signal to unit base board terminals shall be 4 to
20 mA. Sensor shall be equipped with an

37.

38.

39.

40.

41.

42.

43.

44.

45.

override button for timed override. Sensor must


be powered by a separate field-supplied 24-v
transformer.
Suction and Liquid Service Valves:
Shall be equipped with ball type service valves
in the suction and liquid line for each circuit.
Discharge Service Valve:
Shall be equipped with a ball type service valve
in the discharge line of each circuit.
Replaceable Core Filter Drier:
Shall be equipped with a replaceable core filter
drier in each liquid line.
Roof Curb:
Designed to comply with criteria established by
NRCA Guideline B-1986.
a. Size 030-060 Units:
Formed 14-gage galvanized steel with wood
nailer. Supports full perimeter of unit.
b. Size 070-100 Units:
Formed 14-gage galvanized steel with wood
nailer strip as perimeter curb supporting the
air-handling portion of unit, and rail for supporting the condenser portion of the unit.
Roof Curb Condenser Section (accessory for
size 070-100 units only):
Formed 14-gage galvanized steel with wood
nailer strip for supporting condenser section of
the unit to complete a full perimeter curb under
entire unit.
Low Outdoor Sound:
Low sound fans for outdoor sound reduction
shall be available as a factory-installed option
for all units (except 35 ton units).
Low Ambient Control:
a. Control shall regulate fan motor speed in
response to the saturated condensing temperature of the unit. The control shall be
capable of operating with outdoor temperatures at 20 F.
b. Motormaster low ambient control shall be
available as a factory-installed option or fieldinstalled accessory for all units.
Short Circuit Current Rating (SCCR):
An optional SCCR of 65kA shall be provided
for 208/230 and 460 volt units. An optional of
25kA shall be provided for 575 volt units.
Low Compressor Sound Blanket:
Low compressor sound blanket accessory shall
be available for field installation.

Guide specifications 50P2,P3,P4,P5 units


Packaged Rooftop Cooling Unit with
ComfortLink Controls and Optional Electric
or Hydronic Heat
HVAC Guide Specifications
Section 50P2,P3,P4,P5
Size Range: 30 to 100 Tons, Nominal
Carrier Model Number:
50P2 (Vertical Supply/Return,
Constant Volume [CV] Application, Staged Air
Volume [SAV])
50P3 (Vertical Supply/Return,
Variable Air Volume [VAV] Application)
50P4 (Horizontal Supply/Return,
Constant Volume Application, Staged Air
Volume [SAV])
50P5 (Horizontal Supply/Return,
Variable Air Volume Application)
NOTE: Items throughout the specification which apply
only to units with electric or hydronic heat are indicated by
single brackets [i.e.].
Part 1 General
1.01 SYSTEM DESCRIPTION
Outdoor, roof-curb mounted, electronically controlled cooling [and heating] unit utilizing hermetic
scroll compressors with crankcase heaters for cooling duty [and utilizing electric resistance coils for
heating duty]. Units shall supply and return air vertically or horizontally as shown on the contract
drawings.
1.02 QUALITY ASSURANCE
A. Unit shall be rated in accordance with AHRI Standard 340/360, latest edition.
B. Unit shall be designed to conform to ANSI/
ASHRAE 15 (latest edition), ASHRAE 62, and UL
Standard 1995.
C. Unit shall be listed by ETL and ETL, Canada, as a
total package.
D. Roof curb shall be designed to NRCA criteria per
Guideline B-1986.
E. Insulation and adhesive shall meet NFPA 90A
requirements for flame spread and smoke
generation.
1.03 DELIVERY, STORAGE, AND HANDLING
Unit shall be stored and handled per manufacturers
recommendations.
Part 2 Products
2.01 EQUIPMENT
A. Factory-assembled, single-piece heating and cooling
unit. Contained within the unit enclosure shall be all
factory wiring, piping, refrigerant charge (R-410A),
operating oil charge, dual refrigerant circuits, microprocessor-based control system and associated hardware, and all special features required prior to field
start-up.

B. Unit Cabinet:
1. Constructed of galvanized steel (designated G90
per ASTM Standard A653 minimum coating
weight of 0.9 oz of zinc per square foot), bonderized and primer-coated on both sides and
coated with a baked polyester thermosetting
powdercoating finish on the outer surface.
2. Unit casing shall be capable of withstanding
ASTM Standard B117 500-hour salt spray test.
3. Sides shall have man size insulated, double
wall, hinged access doors for easy access to the
control box and other areas requiring servicing.
Each door shall seal against a rubber gasket to
prevent air and water leakage.
4. Interior cabinet surfaces (except heat exchanger
section) shall be insulated with flexible fireretardant dual-density (1.75-lb/cu ft) fiberglass
blanket, coated on the air side. Insulation coating shall be cleanable and shall contain an EPAregistered immobilized antimicrobial agent to
effectively resist the growth of bacteria and
fungi as proven by tests in accordance with
ASTM Standards G21 and G22.
5. Insulation shall be applied by means of adhesion using a water reducible adhesive sprayed
onto interior surface. Adhesive shall maintain a
satisfactory adhesion and cohesion within the
temperature range of 20 to 180 F and have
excellent resistance to water and water vapor
when cured.
6. Unit shall contain a sloped drain pan, to prevent standing water from accumulating. Pan
shall be fabricated of stainless steel. Unit shall
contain a factory-installed nonferrous main condensate drain connection.
7. Units shall be equipped with lifting lugs to facilitate overhead rigging.
C. Fans:
1. Supply Fan:
a. Unit shall have only one fan wheel, scroll,
and motor.
b. Fan scroll, wheel, shaft, bearings, drive components and motor shall be mounted on a
formed steel assembly which shall be isolated from the unit outer casing with factoryinstalled 2-in. deflection spring isolators and
vibration-absorbent fan discharge seal.
c. Fan shall be double-width, double-inlet, centrifugal belt driven forward-curve type with
single outlet discharge (standard) or centrifugal belt driven airfoil blade section type with
single outlet discharge (optional).
d. Fan wheel shall be designed for continuous
operation at the maximum rated fan speed
and motor horsepower.
e. Fan wheel and shaft shall be selected to
operate at 25% below the first critical speed
157

Guide specifications 50P2,P3,P4,P5 units (cont)


and shall be statically and dynamically balanced as an assembly.
f. Fan shaft shall be solid steel, turned, ground
and polished, and coated with rust preventative oil.
g. Fan shaft bearings shall be self-aligning, pillow-block, regreasable ball or roller-type
selected for a minimum average life of
200,000 hours at design operating conditions in accordance with ANSI B3.15.
h. A single motor shall be mounted within the
fan section casing on slide rails equipped
with adjusting screws. Motor shall be
mounted on a horizontal flat surface and
shall not be supported by the fan or its structural members.
i. Fan drive shall be constant-speed fixed-pitch.
All drives shall be factory-mounted, with
belts aligned and tensioned.
2. Condenser Fans:
a. Direct-driven propeller type.
b. Size 035 units shall have a direct driven, 11blade airfoil cross section, reinforced polymer construction, and shrouded-axial type
fans with inherent corrosion resistance.
c. Discharge air vertically upward.
d. Protected by PVC-coated steel wire safety
guards.
e. Statically and dynamically balanced.
f. Three-phase, totally enclosed motors.
D. Compressors:
1. Fully hermetic scroll type compressors with
overload protection and short cycle protection
with minimum on and off timers.
2. Factory rubber-in-shear mounted for vibration
isolation.
3. Reverse rotation protection capability.
4. Crankcase heaters shall only be activated during
compressor off mode.
E. Coils:
1. Evaporator Coil:
a. Intertwined circuiting constructed of aluminum fins mechanically bonded to seamless
copper tubes.
b. Full-face active type during full and part load
conditions.
c. Coils shall be leak tested at 150 psig and
pressure tested at 650 psig.
2. Condenser Coils:
a. Condenser coils shall be microchannel
design. The coils shall have a series of flat
tubes containing a series of multiple, parallel
flow microchannels layered between the
refrigerant manifolds. Microchannel coils
shall consist of a two-pass arrangement. Coil

158

F.

G.

H.

I.

J.

K.

construction shall consist of aluminum alloys


for the fins, tubes and manifolds.
b. Air-cooled condenser coils shall be leak
tested at 150 psig and pressure tested at
650 psig.
Outdoor-Air Hood Assembly:
Factory-installed manual outdoor-air damper shall
allow intake of up to 25% nominal airflow (on units
not equipped with optional economizer).
[Electric Heating Section:]
Electric resistance heaters shall be factory installed,
open wire nichrome element type, insulated with
ceramic bushings, and shall include operating and
safety controls.
[Hydronic Heating Section:]
Hydronic heating option shall consist of factoryinstalled plate fin-tube coil assembly, installed in the
extended length section. Coil assembly shall be supplied with die-formed casing and tube sheets of mill
galvanized steel. Tubes shall be minimum 1/2-in. OD
copper tubes mechanically expanded into aluminum
plate fin coils with belled collars. Headers shall be
constructed of steel with steel MPT connections.
Headers shall have drain and vent connections.
Coils shall be suitable for a design working pressure
of 300 psig at 200 F. Coils shall be tested at
450 psig air pressure.
Refrigerant Components:
Unit shall be equipped with dual refrigerant circuits,
each containing:
1. Filter drier.
2. Moisture indicating sight glass.
3. Thermostatic expansion valve.
4. Fusible plug.
Filter Section:
1. Filter section shall consist of 2-in. thick,
MERV 7 disposable fiberglass filters of commercially available sizes.
2. Factory 2-in. filter track shall allow easy field
conversion to accept 4-in. thick, disposable
fiberglass filters of commercially available sizes.
Controls, Safeties, and Diagnostics:
1. Controls:
a. Control shall be accomplished through the
use of a factory-installed, microprocessorbased control system and associated electronic and electrical hardware. Control
system shall determine control sequences
through monitoring the following operational variables:
1) Day and Time.
2) Schedule (Unoccupied/Occupied).
3) Set points (Unoccupied/Occupied,
Economizer, Duct Pressure, others).
4) Space temperature.
5) Outdoor air temperature.

6)
7)
8)
9)
10)

Unit supply-air temperature.


Unit return-air temperature.
Supply-air fan status.
Economizer position.
Compressor suction and discharge
pressure.
11) Scrolling marquee display.
12) Accessory and/or field-supplied sensors,
function switches and/or signals.
b. Controls shall be capable of performing the
following functions:
1) Capacity control based on supply-air
temperature and compensated by rate
of change of return-air temperature
(VAV) or room temperature (CV).
Capacity control shall be accomplished
through the use of compressor staging
or optional variable output compressors.
2) Perform a quick test to check the status
of all input and output signals to the
control system using scrolling marquee
or Navigator display.
3) Control of integrated economizer
operation, based on unit supply-air
temperature.
4) Supply fan volume control shall control
output from a variable frequency drive to
maintain duct static pressure at userconfigured set point (VAV). Static pressure reset in conjunction with Carrier
communicating terminals to reduce supply fan power requirements. Control
system calculates the amount of supply
static pressure reduction necessary to
cause the most open damper in the system to open more than the minimum
value (60%) but not more than the maximum value (90% or negligible static
pressure drop).
5) Heating control shall provide space temperature control for unoccupied period
heating, morning warm-up sequence
and occupied period heating (when
configured).
6) Adaptive optimal start shall determine
the time unit will commence cooling (or
heating or heating for morning warmup) during the unoccupied mode to
ensure occupied space reaches the set
point in time for occupied mode.
7) Adaptive optimal stop shall turn off the
compressors a preset amount of time
before the end of the occupied mode to
conserve energy (CV only).
8) Alerts and Alarms: Control shall continuously monitor all sensor inputs and
control outputs to ensure safe and
proper system operation. Alerts shall be
generated whenever sensor conditions
have
gone
outside
criteria
for

9)

10)

11)

12)

13)

14)

15)

acceptability. Alarms shall be initiated


when unit control detects that a sensor
input value is outside its valid range (indicating a defective device or connection
that prevents full unit operation) or that
an output has not functioned as
expected or that a safety device has
tripped. Current alarms shall be maintained in STATUS function; up to 9 (current or reset) shall be stored in
HISTORY function for recall.
Timed override function shall permit a
system in unoccupied mode to be
returned to occupied mode for a userconfigured period of 1, 2, 3 or 4 hours
by pressing the override button on the
front of the space temperature sensor.
Nighttime Free Cooling (NTFC) shall
start the supply fan and open the economizer on cool nights to precool the
building structure mass using only outdoor air. Function shall be restricted to
operation above a user-configured low
lockout temperature set point.
Modulating power exhaust control shall
modulate capacity of exhaust fan system
in response to building static pressure
at user-configured set point. Power
exhaust fan operation shall be interlocked with supply fan operation.
Return fan control (on optional return
fan equipped units only) shall measure
supply fan CFM and modulate return
fan to maintain constant CFM differential between supply and return fan.
Return fan operation shall be interlocked with supply fan operation.
Capacity of exhaust air shall modulate in
response to building static pressure at
user-configured set point.
Smoke control functions: Control shall
initiate any of four separate smoke control functions in response to closure of
field switches. Functions shall include:
Pressurization,
Evacuation,
Smoke
Purge and Fire Shutdown. Should two
or more switches be closed simultaneously, Fire Shutdown shall be initiated.
Support demand control ventilation
through a reset of the economizer's minimum position. This reset based on differential CO2 ppm (outdoor and indoor)
can be chosen as linear or as fast or
slow-acting exponential curves.
Indoor air quality (IAQ) mode shall admit
fresh outdoor air into the space whenever space air quality sensors detect
unsuitable space conditions, by overriding economizer minimum damper position. IAQ shall be permitted only during
occupied periods, unless configured to

159

Guide specifications 50P2,P3,P4,P5 units (cont)


16)
17)

18)

19)

20)

21)

22)

23)
24)

25)

160

be allowed during unoccupied periods


also.
Provide control for reheat via auxiliary
heating coil during ventilation.
IAQ pre-occupancy purge function shall
provide complete exchange of indoor air
with fresh air during unoccupied periods, when outdoor conditions permit.
Function shall energize supply fan and
open economizer two hours before next
occupied period; duration of purge shall
be user-configured (5 to 60 minutes).
Outdoor Air Control (OAC) function
shall maintain a minimum quantity of
outdoor airflow into an occupied space.
OAC mode shall be available only during
an occupied period. Outdoor airflow
shall be monitored by an airflow station
and transducer. Economizer maximum
damper opening position during OAC
mode shall be user-configured.
Dehumidification and Reheat: Dehumidification function shall override comfort
condition set points to deliver cooler air
into the space and satisfy a userconfigured humidity set point at the
space or return air humidity sensor.
Reheat function shall energize an auxiliary heating device should dehumidification operation result in cooling of the
space down to the occupied heating set
point.
Supply Air Temperature Set Point
Reset: Control shall automatically reset
the unit supply air temperature set point
on VAV models from either space temperature or return-air temperature, at
user-configured rate and limit. Control
shall also reset supply air temperature
set point via external 2 to 10 vdc signal
representing 0 to 20 F range of reset.
Control shall respond to higher of either
reset if both are active.
Space Temperature Offset function shall
permit occupants to adjust space temperature set point by 5 F using T-56
space sensor (equipped with sliding scale
adjuster).
Lead-lag function shall distribute starts
between the two refrigeration circuits in
an effort to equalize the running time on
the two circuits.
Condenser-fan cycling control shall
maintain correct head pressure down to
0 F.
Refrigeration system pressures shall be
monitored via pressure transducers.
Alarms for low pressure, high pressure
will be permitted.
Timed Discrete Output function shall
control an external function or device
via user-configured activity schedule.

This schedule shall be separate and


different from the units occupied/unoccupied time schedule.
26) Hydronic heating coil control shall modulate a control valve in a steam or
hydronic heat system to maintain space
temperature at user-configured set
points. Control valve actuator shall communicate via LEN (Local Equipment
Network) protocol.
27) Humidifier control shall provide control
for either LEN communicating control
valve or discrete-type output, to maintain space humidity conditions at userconfigured set points.
28) Two-step demand limit control (when
used in conjunction with CEM [controls
expansion module]).
29) Display in Metric units: Display may be
configured to display data in Metric or
English (Imperial) units of measure.
2. Safeties:
Unit components shall be equipped with the following protections:
a. Compressors:
1) Overcurrent using calibrated circuit
breakers
(shuts
down
individual
compressor).
2) Crankcase heaters.
3) High-pressure switch (shuts down individual circuit, automatic reset type).
4) Low-pressure switch (shuts down individual circuit, automatic reset type).
5) Check filter switch.
b. Belt-Drive Fan Motors:
Overcurrent protection manual reset circuit
breakers.
c. [Electric Heating Section]:
1) Automatic reset high-temperature limit
switches.
2) Heat limiters (fusible links).
3) Overcurrent protection manual reset circuit breakers.
4) Branch circuit protection.
3. Diagnostics:
a. The display shall be capable of indicating a
safety lockout condition (alarm) through an
expandable scrolling display.
b. The display shall also be capable of indicating an alert condition which does not lock
out the unit, but informs the system monitor
of a condition which could be detrimental to
either the unit or the comfort of the occupants if allowed to continue.
c. Test mode must also be capable of displaying outputs of microprocessor-controller and
to verify operation of every thermistor,

L.

M.

N.

O.

actuator motor, fan, and compressor before


unit is started.
Operating Characteristics:
1. Unit shall be capable of starting and running at
115 F ambient outdoor temperature per maximum load criteria of AHRI Standard 340/360,
latest edition.
2. Unit shall be capable of mechanical cooling
operation down to 32 F ambient outdoor
temperature (20 F with low ambient
accessory).
3. Provides multi-stage cooling capability.
4. [Provides 2 stages of electric heating capability.]
Motors:
1. Compressor motors shall be cooled by suction
gas passing over motor windings.
2. Condenser-fan motors shall be 3-phase, totally
enclosed type with permanently lubricated
ball bearings and internal over-temperature
protection.
3. Supply and exhaust fan motors shall be of the
3-phase, NEMA rated, open drip-proof (ODP),
ball bearing type, with efficiencies per EISA of
2007 (U.S.A.) requirements.
Electrical Requirements:
All unit power wiring shall enter unit cabinet at a single location.
Special Features:
1. Digital Compressor:
A digital compressor shall be available on the
lead circuit for constant volume and variable air
volume configurations. The ComfortLink control system shall be capable of unloading this
compressor in an infinite number of steps from
100% of unit capacity down to 50% of unit
capacity.
2. Humidi-MiZer Adaptive Dehumidification:
The Humidi-MiZer dehumidification system
shall be factory installed and shall provide
greater dehumidification of the occupied space
by using two modes of dehumidification instead
of the normal design cooling mode of the unit:
a. Subcooling mode shall further sub-cool the
hot liquid refrigerant leaving the condenser
coil when both temperature and humidity in
the space are not satisfied.
b. Hot gas reheat mode shall mix a portion of
the hot gas from the discharge of the compressor with the hot liquid refrigerant leaving
the condenser coil to create a two-phase
heat transfer in the system, resulting in a
neutral leaving-air temperature.
c. The system shall be equipped with modulating control valves to provide precise leaving
air temperature control. On-off, cycling type
control shall not be acceptable.

3. Integrated Economizer:
Dry bulb, differential dry bulb temperature,
enthalpy, or optional differential enthalpy controlled integrated type consisting of dampers,
actuator, and linkages in conjunction with control system to provide primary cooling using
outdoor air, enthalpy permitting, supplemented with mechanical cooling when necessary.
a. Economizer shall meet the requirements of
the California Energy commission airside
economizer acceptance test.
b. Dampers shall be a gear driven low-leakage
type.
c. Actuator shall have a spring-return feature
which shuts dampers upon a power interruption or unit shutdown. Actuators are capable
of internal diagnostics.
d. Equipped with a solid-state humidity sensor
that is capable of sensing outdoor-air heat
content (temperature and humidity) and controlling economizer cut-in point at most economical level. The user can also configure
dew point limiting.
4. Ultra Low Leak Economizer:
Dry bulb, differential dry bulb temperature,
enthalpy, or optional differential enthalpy controlled integrated type consisting of dampers,
actuator, and linkages in conjunction with control system to provide primary cooling using
outdoor air, enthalpy permitting, supplemented with mechanical cooling when necessary.
a. Economizer shall meet the requirements of
the California Energy commission airside
economizer acceptance test.
b. Dampers shall be a gear driven ultra lowleakage type with blade and edge seals.
Dampers shall exhibit a maximum leakage
rate of 4 cfm per square foot of area at
1 in. wg pressure differential when tested in
accordance with AMCA Standard 500.
c. Actuator shall have a spring-return feature
which shuts dampers upon a power interruption or unit shutdown. Actuators are capable
of internal diagnostics.
d. Equipped with a solid-state humidity sensor
that is capable of sensing outdoor-air heat
content (temperature and humidity) and controlling economizer cut-in point at most economical level. The user can also configure
dew point limiting.
5. Modulating Power Exhaust with VFD:
Package shall include 2 double-width, doubleinlet centrifugal belt drive, forward-curved
power exhaust fans with variable frequency
drive control of each fan to maintain a field
adjustable interior space pressure set point.
161

Guide specifications 50P2,P3,P4,P5 units (cont)


a. Fan bearings shall be of the pillow block
type with an average design life of
200,000 hours.
b. Fans shall be statically and dynamically
balanced.
c. Bypass for the VFD shall be available as a
factory-installed option.
6. High-Capacity Modulating Power Exhaust System (75 to 100 ton units only):
High-capacity modulating power exhaust system shall be factory-installed and contain fans
and motors, exhaust hoods and controls (including variable frequency drive and staging
sequence) to maintain space pressure at userconfigured set point.
a. Dual fan assemblies with individual motors.
b. Variable frequency drive for modulating
capacity of lead fan.
c. Staged control on lag fan.
d. Differential pressure transducer for monitoring space pressure.
e. Exhaust air hood assemblies containing
backdraft dampers on each fan outlet, factory installed.
f. All wiring and pressure tubing (except to
space pressure pickup location) shall be factory supplied and installed.
7. Return Fan/Building Pressure Control (75 to
100 ton units only):
a. Functions provided shall be:
1) Airflow control for return duct path
(dedicated to overcoming flow losses in
return duct system).
2) Modulate return airflow rate to track
supply fan airflow rate and maintain a
user set delta cfm between the supply
and return airflow.
3) Maintain building pressure by sensing
building pressure and modulating fan
speed.
b. Option shall consist of following hardware:
1) Plenum fan assembly, with welded steel
airfoil blade fan.
2) Spring isolation.
3) Belt-drive fan system, fixed pitch for
maximum belt life and reliability.
4) Variable frequency drive (VFD) for
return fan modulation control.
5) Supply air cfm and return air cfm sensors to measure supply and return airflow.
6) Exhaust damper with outlet hood.
7) Building pressure transducer.
c. Installation:
1) Site installation shall require supply and
installation of building pressure (BP)
sensing pick-up and tube to connect to
BP transducer in unit.
162

8.

9.

10.

11.

12.

13.

2) All other wiring and pressure tubing


shall be factory-supplied and factory
installed.
Barometric Relief Package:
a. Package shall relieve excess internal pressure and consist of damper assemblies,
hoods, damper screens, seal strips and
required hardware.
b. Damper assemblies shall close due to gravity
upon unit shutoff.
Pleated Filters:
Unit shall be factory equipped with MERV 7
pleated filters having the following characteristics:
a. Efficiency of no less than 30% based on testing per ASHRAE Standard 52.
b. Minimum average arrestance of 95%.
High-Efficiency Pleated Filters (75 to 100 ton
units only):
Unit shall be factory equipped with MERV 11
high-efficiency pleated filters having the following characteristics:
a. Filters shall have a design dust spot efficiency with an average of 60 to 65% based
on the ASHRAE Standard 52.1 test
method.
b. Filters shall have a minimum arrestance of
90%.
c. Filters shall be classified as a Class 2 air filter
according to UL Standard 900.
Bag Filters with Prefilters (30 to 70 ton units
only):
Unit shall be factory equipped with MERV 15
bag filters and 2-in. prefilters, and shall have an
average efficiency of 90% based on testing per
ASHRAE Standard 52.
Cartridge Filters with Prefilters (30 to 70 ton
units only):
Unit shall be factory equipped with cartridge filter mounting system with 2-in. prefilters.
Supply Fan Variable Frequency Drive:
Variable air volume and staged air volume units
shall be equipped with variable frequency drive
(VFD) inverter. The VFD shall be provided with
a metal enclosure and shall be factory-mounted,
wired, and tested. The variable speed drive shall
include the following features:
a. Full digital control with direct control from
the unit ComfortLink controls.
b. Insulated gate bi-polar transistors (IGBT)
used to produce the output pulse width modulated (PWM) waveform, allowing for quiet
motor operation.
c. Inverters capable of operation at a frequency
of 8 kHz so no acoustic noise shall be produced by the motor.

d. Metal enclosure for reduction of RFI (radio


frequency interference).
e. Digital display keypad module, mounted on
the VFD enclosure.
f. Local/Remote and Manual/Auto function
keys on the keypad.
g. UL-listed electronic overload protection.
h. Critical frequency avoidance.
i. Self diagnostics.
j. On-board storage of unit manufacturer's customer user settings, retrievable from the keypad.
k. RS485 communications capability (accessory card source required).
l. Internal thermal overload protection.
m. 5% swinging chokes for harmonic reduction
and improved power factor.
n. All printed circuit boards shall be conformal
coated.
14. Supply Fan Static Pressure Control (VAV units):
Variable air volume units shall be equipped with
a supply fan VFD. The VFD shall control motor
speed to maintain set point static pressure control at the supply duct sensor tube location. The
supply fan drive shall be field-adjustable to
maintain supply duct static pressure set point
from 0.0-in. wg to 5-in. wg, adjusted via scrolling marquee display or Navigator display. A
pressure transducer shall be factory-mounted
and wired. (Control tubing from sensor tube
location to transducer shall be field-supplied and
installed.) Transducer shall provide a 4 to 20
mA signal to the unit control module; unit control module shall provide a 4 to 20 mA signal to
the VFD indicating desired VFD output level
15. Staged Air Volume (SAV) units:
Staged air volume units shall be equipped with a
supply fan VFD. The VFD shall control motor
speed to user configurable speeds. High speed
shall be a percentage of 60 Hz, and shall be
user configurable. The range of adjustment for
high speed shall be between 50 and 100% of
60 Hz. Low speed shall be a percentage of
60 Hz, and shall be user configurable. The
range of adjustment for low speed shall be
between 33 and 67% of 60 Hz. The control
shall allow user configurable fan speeds for
cooling and heating modes.
16. Discharge Plenum:
Discharge plenum design shall contain added
length module for bottom supply air discharge,
as shown in contract drawings. Discharge plenum design shall provide horizontal discharge
arrangement supply fan which shall discharge
into insulated plenum. Interior cabinet surfaces
within discharge plenum section shall be lined

17.

18.

19.

20.

21.

with sheet metal on all surfaces, insulated on


the side opposite the airstream.
Electric heat is not available with discharge plenum models.
Extended Chassis:
Extended chassis designs shall contain an added
length module, after the evaporator section, as
shown in the contract drawings. Module shall
contain tracks to accept field-supplied/installed
auxiliary heating coil.
Non-Fused Disconnect:
A non-fused electrical disconnect for main unit
power shall be factory installed. The disconnect
shall be an interlocking through-the-door type.
115-Volt Convenience Outlet:
A duplex GFCI (ground fault circuit interrupt)
receptacle shall be factory mounted in a weatherproof enclosure and wired for a 10-amp load.
It will remain powered when all unit circuit
breakers have been turned off. The outlet will
be deenergized by the unit disconnect.
Navigator Display Module:
The Navigator display module shall be a portable hand-held display module with a minimum
of 4 lines and 20 characters per line, of clear
English, Spanish, Portuguese or French language. Display menus shall provide clear
language descriptions of all menu items, operating modes, configuration points and alarm
diagnostics. Reference to factory codes shall
not be accepted. An industrial grade coiled
extension cord shall allow the display module to
be moved around the chiller. Magnets shall hold
the display module to any sheet metal panel to
allow hands-free operation. Display module
shall have NEMA 4x housing suitable for use in
outdoor environments. Display shall have back
light and contrast adjustment for easy viewing
in bright sunlight or night conditions. The display module shall have raised surface buttons
with positive tactile response.
Controls Expansion Module (CEM):
Factory-installed package shall include all
hardware for additional control of base unit
operation and product integrated controls features. The functions supported are:
a. Building pressurization, evacuation, and
smoke purge control.
b. Supply air reset from external 4 to 20 mA
signal.
c. Two-step demand limit inputs (when used
with the CCN network).
d. Indoor air quality (IAQ) switch monitoring.
e. Outdoor airflow monitoring.
f. Outdoor humidity monitoring.

163

Guide specifications 50P2,P3,P4,P5 units (cont)

22.

23.

24.

25.

26.

27.

28.

164

g. Space humidity monitoring (required for


dehumidification control, reheat and humidifier control).
h. Return air humidity monitoring.
i. Demand limiting from an external 4 to
20 mA signal.
j. Static pressure reset from an external 4 to
20 mA signal.
Relative Humidity Sensors:
Package shall contain either duct-mounted or
wall-mounted sensors to measure the relative
humidity of the air within the occupied space
(specify location) or return duct and/or outside
air.
NOTE: For relative humidity sensor monitoring,
the CEM must also be ordered.
Indoor Air Quality (CO2) Sensor:
a. Shall have the ability to provide demand ventilation indoor-air quality (IAQ) control
through the economizer with an indoor air
quality sensor.
b. The IAQ sensor shall be available in duct
mount, wall mount, and wall mount with
LED display of CO2 in parts per million. The
set point shall have adjustment capability.
Return Air Smoke Detector:
The smoke detector shall send input to the controller to shut down the unit in case smoke is
detected.
Outdoor Airflow Sensor:
Outdoor airflow sensor package shall contain a
airflow station with airflow sensor, a transducer
and all hardware required to measure the quantity of outdoor air brought in through the economizer dampers. Optional economizer and
CEM are required with this accessory.
Differential Enthalpy Switch or Sensors (when
equipped with both return air and outdoor air
humidity sensors):
a. For use with economizer only.
b. Capable of comparing heat content (temperature and humidity) of outdoor and return air
and controlling economizer cut-in point at
the most economical level.
Hot Gas Bypass:
Unit shall be factory equipped with hot gas
bypass valve, and tubing to maintain capacity
control at minimal cooling loads.
Condenser Coil Protective Coating E-Coated
Microchannel Coil:
E-coated aluminum microchannel coils shall
have a flexible epoxy polymer coating uniformly applied to all coil external surface areas
without material bridging between fins or louvers. Coating process shall ensure complete coil
encapsulation, including all exposed fin edges.

29.

30.

31.

32.

33.

34.

E-coat thickness of 0.8 to 1.2 mil with top coat


having a uniform dry thickness from 1.0 to 2.0
mil on all external coil surface areas, including
fin edges, shall be provided. E-coated coils shall
have superior hardness characteristics of 2H
per ASTM D3363-00 and cross-hatch adhesion
of 4B-5B per ASTM D3359-02. E-coated coils
shall have superior impact resistance with no
cracking, chipping, or peeling per NSF/ANSI
51-2002 Method 10.2.
Condenser Coil Hail Guard (sizes 030 to 060
only):
Canted face enclosure and welded wire grille
complete with support retainers and fasteners
shall be provided for protection of condenser
coils. Field-assembled.
BACnet Communication Option:
Shall provide factory-installed communication
capability with a BACnet MS/TP network.
Allows integration with i-Vu Open Control
System or a BACnet Building Automation
System.
MODBUS Protocol Translator:
A controller-based accessory module shall provide CCN access to MODBUS Remote Terminal Unit (RTU) protocol conversion.
LonWorks Protocol Translator:
A controller-based accessory module shall provide CCN access to LON FT-10A ANSI/EIA709.1 protocol conversion.
Space Temperature Sensor (T-56):
The T-56 space temperature sensor (for CV
applications) shall monitor space temperature.
Device shall be suited for wall mounting in the
occupied space. The T-56 sensor shall incorporate a front-panel located slider switch to effect
a remote change in set point of 5 F. The
T-56 sensor shall also include a button used to
initiate Unoccupied Override function.
Space Temperature Sensor (T-56) with CO2
Sensor:
This device shall incorporate interior space temperature sensing and interior space CO2 level
monitoring functions. Space temperature sensor shall sense the actual temperature in the
conditioned space via 10,000-ohm thermistor.
Temperature set point adjustment potentiometer via slide scale shall provide 5 F adjustment. CO2 sensor shall provide CO2
measurement range of 0 to 2000 ppm. IAQ
signal to unit base board terminals shall be 4 to
20 mA. Sensor shall be equipped with an override button for timed override. Sensor must be
powered by a separate field-supplied 24-v
transformer.

35. Suction and Liquid Service Valves:


Shall be equipped with ball type service valves
in the suction and liquid line for each circuit.
36. Discharge Service Valve:
Shall be equipped with a ball type service valve
in the discharge line of each circuit.
37. Replaceable Core Filter Drier:
Shall be equipped with a replaceable core filter
drier in each liquid line.
38. Roof Curb:
Designed to comply with criteria established by
NRCA Guideline B-1986.
a. Size 030-060 Units:
Formed 14-gage galvanized steel with wood
nailer. Supports full perimeter of unit.
b. Size 070-100 Units:
Formed 14-gage galvanized steel with wood
nailer strip as perimeter curb supporting the
air-handling portion of unit, and rail for supporting the condenser portion of the unit.
39. Roof Curb Condenser Section (accessory for
size 070-100 units only):
Formed 14-gage galvanized steel with wood
nailer strip for supporting condenser section of
the unit to complete a full perimeter curb under
entire unit.
40. [SCR Controlled Electric Heat (30 to 70 ton
units only):]
a. SCR electric heat option shall monitor unit
supply-air temperature and control the unit
heater section to provide the following
sequences:
1) Demand heating control, with modulation to maintain user-configured heating
supply air temperature set point.
2) Full output heating on heating control
command.

41.

42.

43.

44.

3) Tempering heat control, based on userconfigured ventilation supply air temperature set point, to eliminate cold draft
conditions with low mixed-air temperatures.
b. SCR heat control option shall consist of:
1) SCR controller capable of ensuring the
proper heating rates.
2) Supply air temperature thermistors with
duct-mounting base.
3) Limit switch temperature thermistors.
c. Field installation shall be limited to installing
three supply air temperature thermistors in
the supply duct. All other hardware and wiring shall be factory-completed.
Low Outdoor Sound:
Low sound fans for outdoor sound reduction
shall be available as a factory-installed option
for all units (except 35 ton units).
Low Ambient Control:
a. Control shall regulate fan motor speed in
response to the saturated condensing temperature of the unit. The control shall be
capable of operating with outdoor temperatures at 20 F.
b. Motormaster low ambient control shall be
available as a factory-installed option or fieldinstalled accessory for all units.
Short Circuit Current Rating (SCCR):
An optional SCCR of 65kA shall be provided
for 208/230 and 460 volt units. An optional of
25kA shall be provided for 575 volt units.
Low Compressor Sound Blanket:
Low compressor sound blanket accessory shall
be available for field installation.

165

Index
Airflow
Maximum 7, 138
Minimum 7, 138
Application data 138, 139
Auxiliary coil 138, 139
Chassis arrangement 30-32
Extended length 31, 32
Horizontal discharge 31, 32
Standard length 30, 31
Vertical discharge 30-32
ComfortID controls 4
ComfortLink controls 1,2, 132
Compressor staging 22,23
Control expansion module 129
Controls 129- 137
Cooling capacities 46-102
Digital scroll compressor 3, 22, 23
Dimensions 33-43
Accessory 39-43
Base unit 33-38
Economizer 131
Electrical data 127, 128
Electric heater capacity 12
Features/Benefits 1-5
Gas heat capacity 7-12
Guide specifications 148-165
48P2,P3,P4,P5 148-156
50P2,P3,P4,P5 157-165
Hinged access doors 3
Horizontal applications 31, 32
Humidi-MiZer system 3, 45
Indoor air quality (IAQ) 4, 131
Integrated gas controller (IGC) 5, 129
Maximum outdoor temperature 138
Minimum outdoor temperature 138
Model number nomenclature 6
Novation technology 2, 3
Options and accessories 29-32
Performance data 45-126
Physical data 13-28
48P2,P3,P4,P5 13-17, 22-28
50P2,P3,P4,P5 18-28
Piping and wiring (typical installation) 140
Power exhaust 4, 22
Drive data 28
Fan performance 123, 124
Motor limitations 128
Return fan 22, 28
Drive data 28
Roof curb dimensions 39-43
Condenser section roof curb 42, 43
Selection procedure 44
Smoke control 132
Staged gas control 3, 130
Static pressure drop 125, 126
Economizer 125, 126
Electric heat 125, 126
High-capacity coil 125, 126
Gas heat 125, 126
Hydronic coil 125, 126
Power exhaust 125, 126
Supply fan motor
Drive data 27
Motor limitations 127
Performance 103-124
Thru-the-curb connections 138
Unit-mounted disconnect 5
Variable frequency drive 4
Vertical discharge applications 4, 30-32

166

Weight
Operating 13-21
Options and accessories 27
Roof curb 27
Unit distribution 24-26
Wiring 141-147
Power wiring 141
115-Volt 146
Controls 144, 145
Input/Output 142, 143
Main Base Board 142

Carrier Corporation Syracuse, New York 13221

3-13

Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.
Section 1 2
Pg 168
Catalog No. 04-52480033-01
Printed in U.S.A.
Form 48/50P-7PD
Replaces: 48/50P-6PD
Tab
1c 2c

You might also like