100% found this document useful (1 vote)
357 views21 pages

Software Manual 2

The document provides instructions for using software for a laser cutting and engraving system. It discusses starting up the system and navigating the main menu to select files, delete files, view file information, and configure system settings. It describes how to set up laser current, home position, buzzer sound, time, motor type, work area, area limitations, and laser head settings. It also covers formatting the memory and troubleshooting issues.

Uploaded by

iovacarmen
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOC, PDF, TXT or read online on Scribd
100% found this document useful (1 vote)
357 views21 pages

Software Manual 2

The document provides instructions for using software for a laser cutting and engraving system. It discusses starting up the system and navigating the main menu to select files, delete files, view file information, and configure system settings. It describes how to set up laser current, home position, buzzer sound, time, motor type, work area, area limitations, and laser head settings. It also covers formatting the memory and troubleshooting issues.

Uploaded by

iovacarmen
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOC, PDF, TXT or read online on Scribd
You are on page 1/ 21

Andrma ve Kesim iin Yazlm Sistemi

KULLANICI EL KTABI

The instruction for normal model with off-line control card

Wuhan Golden Laser Equipments Manufacturing Co.,Ltd.


Add: GOLDEN LASER Building, NO.188 . BaiBuTing District, Wuhan City,HuBei Province, P.R China. Tel: 0086-27-82943848 Fax: 0086-27-82944068 Http: www.goldenlaser.cn E-mail: [email protected]

www.goldenlaser.cn

CATALOGUE

Chapter 1. The menu for start and setup for button.........................................................................................2 Chapter 2. Interface setup................................................................................................................................4 Chapter 3 Function Setup..................................................................................................................................8 Chapter 4 Format EMS memory....................................................................................................................12 Chapter 5 System Information.......................................................................................................................12 Chapter 6 The process of USB........................................................................................................................13 Chapter 7 Process of transmit the date............................................................................................................16 Chapter 8. Alarm dialog box ..........................................................................................................................19 Chapter 9 Malfunction and examination........................................................................................................21

Chapter 1. The menu for start and setup for button


When the machine is on, there will appear Welcome Golden Laser. It is as below.
2

www.goldenlaser.cn

After 5 seconds, it will appear as below, if set the return home, the machine will appear as below.

When X.Y goes to home, the machine will appear Idle as below:

Explanation: It means the machine is idle, wait for the sign to next step operate. When the machine is idle, press up, down, left, right to move X and Y axis, it is as below: Press Up button.

It indicates Y axis will move up direction. Press Down button.

www.goldenlaser.cn

It indicates Y axis will move down direction. Press Left button.

It indicates X axis will move left direction. Press Right button.

It indicates X axis will move right direction.

Chapter 2. Interface setup


Click the button of Setup, it will appear the picture as below:

www.goldenlaser.cn

Press Down, it will appear the second picture as below:

Press Down again, there will appear the third picture as below:

The first row: select the processing file The second row: delete the processing file The third row: process the file information The fourth row: setup for the systemic file The fifth row: formatting EMS memory The sixth row: system information The seventh row: save the position 2.1 Select the processing file At first, move the cursor to the first row, click right button, then enter the processing file selection, as below:

www.goldenlaser.cn

Select the required processing file (The file which the cursor points is the selected one), then click right button for make sure, and click delete to return the idle display, click start, it will begin to process the selected one. 2.2 Delete the file When you neednt some processing files, or it already saved 10 files and cant save others, please delete some files. The function is as below. Firstly, please move the cursor to the second row (delete file) for the setup menu, and then click right to select the files which you need to delete. It is as below:

Click the right button, then you can delete the pictures which you neednt process. 2.3 Information for processing file. When you want to read the file, including the processing times and power or speed adjusting, please enter the processing file information to check the parameter, the function is as below Please move the cursor to the third row (processing information), click right to enter and it will appear the processing file in the card as below:

Select the files needed to be check, and then click the right button, you will check it as the diagram:

www.goldenlaser.cn

The first row: Run time is the processing time The second row: Processing speed The third row: Power adjust The fourth row: Counter, time 2.4 System file setup When you need to setup the system file, please move the cursor to the fourth row (system setup), it is as below,

Click the right button to enter, in order to prevent the inaccurate function, please input the password. It is as below:

The password is: Up, down, left, right, start, stop, input this in turn to enter the system setup. After you enter the system setup, there three pages for the parameter. It is as below:

www.goldenlaser.cn

The first row: laser adjust setup The second row: go to home position setup. The third row: buzzer sound setup The fourth row: setup for the systemic time The fifth row: setup for the motor type The sixth row: setup for working area The seventh row: setup for area limitation The eighth row: laser setup The ninth row: laser distance setup

Chapter 3 Function Setup


3.1 Laser current setup After enter system setup, please move the cursor to the first row of laser setup, enter Right button to enter, laser setup current is as below,

www.goldenlaser.cn

Select the current percentage, but it cant too big. The reference value is 1%-2.8% according to the different laser tubes. 3.2 Return to home position When cursor moved to the second row (Go to home setup) of the system setup, press Right to enter, it is as below:

When cursor moved to Yes, then press setup for confirmation, when start, X,Y axis will go to home automatically, if move to No, press setup for confirmation, X,Y axis will not go to home after start. 3.3 Buzzer sound setup Move the cursor to the third row (Buzzer sound setup) of system setup, and then press Right to enter, it is as below:

The setup for buzzer sound is from 0-9. Select the required sound times, and then clicks setup for confirmation. Then press Exit to the idle situation. 3.4 System time setup Move the cursor to the fourth row (system time setup) and then press Right to enter. It is as below:

www.goldenlaser.cn

Setup the year, month, date and current time, after it, please press setup to confirm, press exit to return to the idle state, it is finished to modify the time. 3.5 Motor type setup Move the cursor to the fifth row (Motor type setup), and then press Right to enter, it is as below:

The first row: Step motor The second row: Servo motor If the X, Y axis is used with Step motor, please move the cursor to the first row, and then press setup for confirmation. If the X, Y axis is used with Servo motor, please move the cursor to the second row, and then press setup for confirmation. After the setup, please press exit to exit, it is finished by the motor type setup. 3.6 Setup the working area. Please move the cursor to the sixth row (working area setup), and then press Right to enter, it is as below:

If setup the working area of X, please move the cursor to X: 00800, (the initial state is X:
10

www.goldenlaser.cn

00000), then press Right to enter, there will be occur the shining cursor, whose position can be adjusted the parameter through Up and Down. Press Up means add, press Down means decrease, after setup the parameter of X according to the working table size, press exit (It will be totally exit without saving if press two times). And then move the cursor to the Y: 00400, (the initial state is Y: 00000), press Right to enter, at this time, there will be shining cursor for the Y parameter. It is the same setup with X parameter setup. After the setup, press exit and move the cursor to Pitch: 032 (the initial state is 000), the setup mode is the same with X parameter setup. After total setup of X, Y, please press Setup for confirmation. At last, press exit to finish the total setup. 3.7 working area limitation Please move the cursor to the seventh row (working area limitation), and the press Right to enter, it is as below:

Yes is adding the function of working area limitation, if select yes, it will alarm when exceeding the working area, if select no, it is no limitation for the working area. 3.8 Laser head setup When the cursor moved to the eighth row (Laser head setup), please click Right to enter, it is as below:

Alternative laser light: It means laser 1 and laser 2 will process to produce light by turns, it is used for double system laser machines. Laser 1: The single laser machine will make one laser tube to produce light, it must be adjusted laser 1 produce light, or it will appear no light after a period of processing. Laser 2: It is laser 2 produce light, mainly used for double system of laser 2 to produce light by turns, if laser 1 has something wrong, it can be selected laser 2 for processing.

11

www.goldenlaser.cn

3.9 Laser distance Please move the cursor to the ninth row (laser distance), it is as below:

When the machine produces light by turns, it means the distance between the light produced from laser 1 and laser 2. The setting method: Please firstly move the cursor to the position of X, and then press right to adjust the X parameter, press test button, it can test whether the two laser heads light point will be superposition, when it is superposition, please press setup to confirm for saving it. In the models of double system, it will produce light by turns to process. The reference value is 48.5mm.

Chapter 4 Format EMS memory


We suggest USB format, if there is some confusion of system, machining abnormity move cursor to format EMS memory, and pressRight button to enter. It is as below

Move cursor to Yand press Setup to confirm, The EMS memory can be format if we do it like this.

Chapter 5 System Information


Move cursor to system information, and then press the right button to enterit is as below
12

www.goldenlaser.cn

And press the right button to enter as follows

Edition information is the number of edition on display control card.

Chapter 6 The process of USB


6.1 Return to home if you cant setup the machine return to home, please do it like that firstly, otherwise it will broken the machine. The machine will return to the home if you press the home button when the machine stops as follows

6.2 Guide the picture and put into the U disk it will appear as follows:

Choose the document which you need to processand press theRightbutton to confirm

13

www.goldenlaser.cn

It will appear the dialog box, if there is a picture have the same name as follows:

Note Cover with the original pictureYes orNo?If Yes press Rightbutton to confirmso the picture will covered with another picture which in the U disk. 6.3 Setup scope Press the setup button to enter into the setup menu and move the cursor to the sixth Work area press Rightbutton and enter into it, and input the password and enter into the setup interfacework areaset up the parameter of X,Y and so on after enter into the setup. Please press the button Setup to confirm.No need to operate this step if the picture is ok.. 6.4 Process the picture Make sure the location of material by draw frame as follows

6.5 Press the button of start to process the picture, it will appear the following picture when processing

14

www.goldenlaser.cn

6.6 Please press the button of Pause on the Control panel if you want to stop a while during moving as follows

6.7 Please press the button of Stop on the control panel if you want to stop during wroking as follows

6.8 If you find some situation like the power too large, or the speed too quick, or the equipment stop to work Please adjust the coder button by yourself to control the speed and power in the I die condition, it will make the quality better. It will appear the following picture when you adjust the speed

It will appear the following picture when you adjust the power

6.9 You can keep the same location if you want to do the same picture next time after machining as follows

15

www.goldenlaser.cn

Chapter 7 Process of transmit the date


7.1 Introduction of function

Editor Toolbar

Standard Toolbar

Display Toolbar

Control Panel

The area of editor picture

Establish Toolbar

Picture Toolbar

Status Bar

16

www.goldenlaser.cn

There are eight parts when you open the Golden Laser USB control software as follows Editor Toolbar, Standard Toolbar, Display Toolbar, Control Panel, The area of editor picture, Establish Toolbar, Picture Toolbar, Status Bar. 7.2 Guide or open the machining document Dot or button on the software, guide or open the picture of machining panel, please check the introduction of USB card software if you need to set up, typeset.

7.3 Setting of machining picture It will appear the following dialog box when you double dot the picture on the control panel

17

www.goldenlaser.cn

Length of overlap in seal It will appear the location in seal cant overlap when you machining the pictureyou can repair the length of overlap if you setting this parameter. Power of machiningThe laser power when you machining with quick speed. Lowest speedThe laser power when you machining with slow speed. Speed of machiningThe speed of machining the date of picture. Acceleration of machiningIt means from the starting speed to machining speed when machine is working. If you set the system parameter with automatic, so the parameter cant be amend. But you can amend it if you set it by hand. Space between of BMP engrave: Scan space between when you scan the BMP and this function only can be setting when you machining BMP. Power of BMP machining The laser power when you machining BMP, and this function only can be setting when you machining BMP. Space of FillingPlease fill the space of line when you fill the picture. Draw frameIf you press this button, it will draw the picture out of frame when filling, otherwise not. Filling Angle Fill the picture of vector, please fill the angle. Holistic filling You need to choose the way to fill, one the holistic filling, another is aliquot filling. FillingPlease dot this button after setting the parameter of filling. Time of machiningThis layer need to setting time of machining. Input YES or NoDo you need to machiningYES or No.

7.4 Process of picture

Down load Create Data

Please dot the button of machining date after setting of parameter, , the date will arrive to machine through USB port, and there are two documents as follows:

18

www.goldenlaser.cn

You can define the name of document by yourself after download, or pretermit. The display toolbal of information show the speed to download It will appear after finished. Please dot the key of frame to make sure the location of material, and dot the START to machining. 7.5 Repeated machining The data will saved by USB card. You only need to take the date out of the USB card to machining if you want to do the same picture. No need to download by computer.

Chapter 8. Alarm dialog box


8.1 Alarm of excess working scope

19

www.goldenlaser.cn

8.2 The document has existed. Cover YES or No?

8.3 Out of the date

8.4 Errors to open the document

8.5 No processing file

8.6 Alarm of use term

20

www.goldenlaser.cn

When your machine is expired please contact with us and reference the how to update amnual.

Chapter 9 Malfunction and examination


Malfunction Hit Hit No laser after some machining time There is some abnormity when machining Excess the working scope Out of the date Errors to open the document or no document Examination Without back to the home open the machine, and turn to the home. No limit of working scope, please setting Setting laser tube to work alternant Confused of system, please format EMS memory Please turn back to the origin and setting the working scope and distance in correct. Please login again otherwise cant use it. No date in control card

21

You might also like