10CTQ150
10CTQ150
Schottky Rectifier, 2 x 5 A
FEATURES
Base 2 common cathode
175 C TJ operation Center tap configuration Low forward voltage drop High frequency operation
High purity, high temperature epoxy encapsulation for enhanced mechanical strength and moisture resistance
Anode Anode 2 1 Common 3 cathode
TO-220AB
Guard ring for enhanced ruggedness and long term reliability Designed and qualified for industrial level
This center tap Schottky rectifier series has been optimized for low reverse leakage at high temperature. The proprietary barrier technology allows for reliable operation up to 175 C junction temperature. Typical applications are in switching power supplies, converters, freewheeling diodes, and reverse battery protection.
VOLTAGE RATINGS
PARAMETER Maximum DC reverse voltage Maximum working peak reverse voltage SYMBOL VR VRWM 10CTQ150 150 UNITS V
Maximum peak one cycle non-repetitive surge current per leg See fig. 7 Non-repetitive avalanche energy per leg Repetitive avalanche current per leg
TJ = 25 C, IAS = 0.30 A, L = 150 mH Current decaying linearly to zero in 1 s Frequency limited by TJ maximum VA = 1.5 x VR typical
www.vishay.com 1
10CTQ150
Vishay High Power Products Schottky Rectifier, 2 x 5 A
ELECTRICAL SPECIFICATIONS
PARAMETER SYMBOL 5A Maximum forward voltage drop per leg See fig. 1 VFM
(1)
TEST CONDITIONS TJ = 25 C
VALUES 0.93 1.10 0.73 0.86 0.05 7 0.468 28 200 8.0 10 000
UNITS
10 A 5A 10 A
TJ = 125 C VR = Rated VR
Maximum reverse leakage current per leg See fig. 2 Threshold voltage Forward slope resistance Maximum junction capacitance per leg Typical series inductance per leg Maximum voltage rate of change Note (1) Pulse width < 300 s, duty cycle < 2 %
TJ = 25 C TJ = 125 C TJ = TJ maximum
mA V m pF nH V/s
VR = 5 VDC (test signal range 100 kHz to 1 MHz) 25 C Measured lead to lead 5 mm from package body Rated VR
10CTQ150
www.vishay.com 2
10CTQ150
Schottky Rectifier, 2 x 5 A
100
100
10
TJ = 175 C TJ = 125 C TJ = 25 C
25
50
75
100
125
150
1000
100 TJ = 25 C
10
20
40
60
80
100
120
140
160
VR - Reverse Voltage (V) Fig. 3 - Typical Junction Capacitance vs. Reverse Voltage (Per Leg)
10
1 D = 0.75 D = 0.50 D = 0.33 D = 0.25 D = 0.20 Single pulse (thermal resistance) 0.001 0.00001
PDM t1 t2
0.1
0.01
Notes: 1. Duty factor D = t1/t2 . 2. Peak TJ = PDM x ZthJC + TC 0.001 0.01 0.1 1 10
.
100
0.0001
www.vishay.com 3
10CTQ150
Vishay High Power Products Schottky Rectifier, 2 x 5 A
180 5
170 160 150 140 130 See note (1) 120 0 2 4 Square wave (D = 0.50) 80 % rated VR applied
DC
0 6 8 0 1 2 3 4 5 6 7 8
1000
At any rated load condition and with rated VRRM applied following surge
100
10
100
1000
10 000
D.U.T.
IRFP460 Rg = 25
Current monitor
Fig. 8 - Unclamped Inductive Test Circuit Note (1) Formula used: T = T - (Pd + Pd C J REV) x RthJC; Pd = Forward power loss = IF(AV) x VFM at (IF(AV)/D) (see fig. 6); PdREV = Inverse power loss = VR1 x IR (1 - D); IR at VR1 = 10 V
www.vishay.com 4
10CTQ150
Schottky Rectifier, 2 x 5 A
10
1 1 2 3 4 5 6 -
C
2
T
3
Q
4
150
5
Package T = TO-220
Schottky Q series Voltage rating (150 = 150 V) None = Standard production PbF = Lead (Pb)-free
www.vishay.com 5
Disclaimer
All product specifications and data are subject to change without notice. Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively, Vishay), disclaim any and all liability for any errors, inaccuracies or incompleteness contained herein or in any other disclosure relating to any product. Vishay disclaims any and all liability arising out of the use or application of any product described herein or of any information provided herein to the maximum extent permitted by law. The product specifications do not expand or otherwise modify Vishays terms and conditions of purchase, including but not limited to the warranty expressed therein, which apply to these products. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document or by any conduct of Vishay. The products shown herein are not designed for use in medical, life-saving, or life-sustaining applications unless otherwise expressly indicated. Customers using or selling Vishay products not expressly indicated for use in such applications do so entirely at their own risk and agree to fully indemnify Vishay for any damages arising or resulting from such use or sale. Please contact authorized Vishay personnel to obtain written terms and conditions regarding products designed for such applications. Product names and markings noted herein may be trademarks of their respective owners.
www.vishay.com 1