91% found this document useful (34 votes)
36K views

Daily Welding Machine Inspection Checklist

The daily welding machine inspection checklist ensures welding machines are in good working order and work areas are safe. It checks that welding machines have earthing, drip trays, and accessible fire extinguishers. Terminals and joints must be secured and insulated, and cables properly insulated without exposed wires of a suitable size. Electrode holders and clamps must be defect-free and electrodes detached when not in use. Work areas should be clear of combustibles with fire blankets and good housekeeping.
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
91% found this document useful (34 votes)
36K views

Daily Welding Machine Inspection Checklist

The daily welding machine inspection checklist ensures welding machines are in good working order and work areas are safe. It checks that welding machines have earthing, drip trays, and accessible fire extinguishers. Terminals and joints must be secured and insulated, and cables properly insulated without exposed wires of a suitable size. Electrode holders and clamps must be defect-free and electrodes detached when not in use. Work areas should be clear of combustibles with fire blankets and good housekeeping.
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

DAILY WELDING MACHINE INSPECTION CHECKLIST Contractor : Description

WELDING MACHINE In good working condition Provided with earthing or grounding Provided with drip tray (Dry) Fire extinguisher is available Fire extinguisher is available TERMINALS /JOINTS In good working condition Secured and effectively insulated CABLES Properly insulated and no exposed cables Size of cable suitable for voltage supply Hang up to prevent tripping hazard Hang on insulated hook or material Cables and joints are proper and in good condition ELECTRODE HOLDER / CLAMP Electrode holder is free from defects Return cable clamp is free from defects Detach electrodes when not in use WORK AREA No combustible or flammable materials Fire blanket is provided Maintain good housekeeping

Welding machine no. : 1 2 3 4 5 6 7 8 9

Location :

Month :

Year 30 31 Remarks

10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29

ForemanSignature Supervisor Signature