manual of sensor Turck Inductive Proximity Number Decode. Add additional information to improve discoverability! Rizzoni provides a solid overview of the electrical engineering discipline that is especially geared toward the many non-electrical engineering students who take this course. The hallmark feature of the text is its liberal use of practical applications to illustrate important principles. The applications come from every field of engineering and feature exciting technologies such as Ohio State’s world-record setting electric car. The appeal to non-EE’s is further heightened by such special features as the book’s Focus on Measurement sections, Focus on Methodology sections, and Make the Con

Uploaded by

Kenan Baltaci
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
120 views

Turck Inductive Proximity Number Decode, Ohio, Number

manual of sensor Turck Inductive Proximity Number Decode. Add additional information to improve discoverability! Rizzoni provides a solid overview of the electrical engineering discipline that is especially geared toward the many non-electrical engineering students who take this course. The hallmark feature of the text is its liberal use of practical applications to illustrate important principles. The applications come from every field of engineering and feature exciting technologies such as Ohio State’s world-record setting electric car. The appeal to non-EE’s is further heightened by such special features as the book’s Focus on Measurement sections, Focus on Methodology sections, and Make the Con

Uploaded by

Kenan Baltaci
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

Inductive Sensors

Inductive Sensor Part Number Key

B i 15 U Mounting
B N = Embeddable = Nonembeddable

CK 40

- A

6 X2

Wiring Options Special Option Codes


Number of LEDs
Examples: Blank = No LEDs X2 = 2 LEDs

Principle of Operation
i = Inductive

Voltage Range
AC/DC: (No SCP**) 3 = 20-250 VAC, 10-300 VDC 14 = 20-132 VAC, 10-140 VDC 31 = 20-250 VAC, 10-300 VDC, Plastic Barrel 33 = 35-250 VAC, Grounded Metal Barrel AC/DC: 30 = 32 = 40 = (Latched SCP) 20-250 VAC, 10-300 VDC 20-250 VAC, 10-300 VDC 20-140 VAC/DC, High Off-State Current

Rated Operating Distance (mm) Sensing Characteristics


F NF S T U = = = = = Front Sensing on Q26 and Q34 Sensor Nonferrous Only Side Sensing on Q26 Sensor Side Sensing on Q34 Sensor Uprox Sensor

DC: 4 = 10-65 VDC, Polarity Protected, Pulsed SCP** 6 = 10-30 VDC, Polarity Protected, Pulsed SCP 7 = 10-30 VDC, TTL Compatible 8 = 20-30 VDC, Polarity Protected, Pulsed SCP 41 = 10-65 VDC, Polarity Protected, Pulsed SCP 61 = 10-30 VDC, Polarity Protected, Pulsed SCP **SCP = Short-Circuit and Overload Protection

Housing Material Modifier


E = Stainless Steel

Output
D DZ LF G N P R Z = = = = = = = = 2-Wire DC (Transistor Output) 2-Wire AC/DC, (Power MOSFET Output) Frequency Output 2-Wire DC, Low Voltage Drop NPN Transistor (Current Sinking) PNP Transistor (Current Sourcing) Relay Output 2-Wire AC or 2-Wire AC/DC

Housing Style
Rectangular Q = Metal or Plastic, Various Rectangular Styles Limit Switch CA = stubby, Short Aluminum Housing, Connector CK = stubby, Short Plastic Housing, Connector CP = combiprox, Plastic Housing, Terminal Chamber Base with Removable Sensor

Output Function
A DA F R U V Y0 Y1 = = = = = = = = Normally Open (N.O.) Dynamic Output (Ring Sensor), Normally Open Connection Programmable (N.O. or N.C.) Normally Closed (N.C.) Jumper Programmable (N.O. or N.C.) Complementary Outputs: One N.O., One N.C. NAMUR Output, Requires Switching Amplifier NAMUR Output, Requires Switching Amplifier

Housing Diameter/Height (mm) or CRS Probe Length (mm = Number/10)

B3

TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-544-PROX Fax: (763) 553-0708

www.turck.com

Industrial Automation

Wiring Options A) Connectorized Sensor


Rectangular B4

Bi15-Q20-AN6X2- H1 1 4 1
Wiring Configuration Connector Family
B1 = minifast , Metal, Male B2 = minifast , Plastic, Male B3 = microfast , Metal, Male H1 = eurofast , Metal or Plastic, Male V1 = picofast , Metal, Male V2 = picofast , Snap and M8x1, Male (Q08 Only) Example: 1 = Standard 3 = N.C. DC Output on Pin 4 (for US)

Number of Pins

Connector / Sensor Transition


1 = Straight

B) Potted Cable Bi15-Q20-AN6X2- 7M


Cable Length
Blank = 2 Meter cable 7M = 7 Meter cable

Special Option Codes Bi 5-Q08-AN6XS- /S34

Option Code
Example: /S34 = Weld Field Immune /S97 = -40C (-40F) Operating Temperature /S100 = +100C (+212F) Operating Temperature /S1589 = Barrel sensors with weldguard laminate

TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-544-PROX Fax: (763) 553-0708

www.turck.com

Inductive Sensors

Inductive Sensor Part Number Key B i 10 U Mounting


B N = Embeddable = Nonembeddable

G T 30

- A DZ 30 X2

Wiring Options Special Option Codes


Number of LEDs
Examples: Blank = No LEDs X2 = 2 LEDs

Principle of Operation
i = Inductive

Voltage Range
AC/DC: (No SCP**) 3 = 20-250 VAC, 10-300 VDC 14 = 20-132 VAC, 10-140 VDC 31 = 20-250 VAC, 10-300 VDC, Plastic Barrel 33 = 35-250 VAC, Grounded Metal Barrel AC/DC: 30 = 32 = 40 = (Latched SCP) 20-250 VAC, 10-300 VDC 20-250 VAC, 10-300 VDC 20-140 VAC/DC, High Off-State Current

Rated Operating Distance (mm) Sensing Characteristics


F NF S T U = = = = = Front Sensing on Q26 and Q34 Sensor Nonferrous Only Side Sensing on Q26 Sensor Side Sensing on Q34 Sensor Uprox Sensor

Housing Material Modifier


E = Stainless Steel

Housing Style
Barrel - Metal G = Full Threading, Generally Chrome Plated Brass H = Smooth, Chrome Plated Brass or Stainless Steel M = Partial Threading, Chrome Plated Brass Barrel - Plastic K = Smooth KT = PVDF, Smooth P = Full Threading PT = PVDF, Full Threading S = Partial Threading T = Right Angle Rectangular Q = Metal or Plastic, Various Rectangular Styles Limit Switch CA = stubby, Short Aluminum Housing, Connector CK = stubby, Short Plastic Housing, Connector CP = combiprox, Plastic Housing, Terminal Chamber Base with Removable Sensor A DA F R U V Y0 Y1

DC: 4 = 10-65 VDC, Polarity Protected, Pulsed SCP** 6 = 10-30 VDC, Polarity Protected, Pulsed SCP 7 = 10-30 VDC, TTL Compatible 8 = 20-30 VDC, Polarity Protected, Pulsed SCP 41 = 10-65 VDC, Polarity Protected, Pulsed SCP 61 = 10-30 VDC, Polarity Protected, Pulsed SCP **SCP = Short-Circuit and Overload Protection

Output
D DZ LF G N P R Z = = = = = = = = 2-Wire DC (Transistor Output) 2-Wire AC/DC, (Power MOSFET Output) Frequency Output 2-Wire DC, Low Voltage Drop NPN Transistor (Current Sinking) PNP Transistor (Current Sourcing) Relay Output 2-Wire AC or 2-Wire AC/DC

Output Function
= = = = = = = = Normally Open (N.O.) Dynamic Output (Ring Sensor), Normally Open Connection Programmable (N.O. or N.C.) Normally Closed (N.C.) Jumper Programmable (N.O. or N.C.) Complementary Outputs: One N.O., One N.C. NAMUR Output, Requires Switching Amplifier NAMUR Output, Requires Switching Amplifier

Secondary Barrel Modifier


E H K LD M SK SR T WD S = Extended Barrel Length = Weldguard /Stoneface = Short Barrel Length = Load Dump = Medium Barrel Length = Right-Angle Terminal Chamber = Straight Terminal Chamber = Barb Fitting at Cable Entry = Washdown IP 67/IP 68/IP 69K = Side Sensing

Housing Diameter/Height (mm) or CRS Probe Length (mm = Number/10) Primary Barrel Modifier
T = Teflon Coated

C5

TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-544-PROX Fax: (763) 553-0708

www.turck.com

Industrial Automation

Wiring Options A) Connectorized Sensor Bi 2-M12-AN6X- H1 1 4 1


Wiring Configuraton Connector Family
B1 = minifast , Metal, Male B2 = minifast , Plastic, Male B3 = microfast , Metal, Male H1 = eurofast , Metal or Plastic, Male V1 = picofast , Metal, Male V2 = picofast , Snap and M8x1, Male (Q08 Only) Example: 1 = Standard 3 = N.C. DC Output on Pin 4 (for US)

Number of Pins

Connector / Sensor Transition


1 = Straight 3 = Straight with Adapter 4 = Right-Angle with Adapter

B) Potted Cable Bi 2-G12-AN6X- 7M


Cable Length
Blank = 2 Meter cable 7M = 7 Meter cable

Special Option Codes Bi 2-S12-AN7X- /S100


or

Bi10R-W30-DAN6X-H1141 /F2
Option Code
Example: /F2 = Alternate Oscillator Frequency

Option Code
Example: /S34 = Weld Field Immune /S97 = -40C (-40F) Operating Temperature /S100 = +100C (+212F) Operating Temp. /S1589 = Barrel sensors with Weldguard laminate

TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-544-PROX Fax: (763) 553-0708

www.turck.com

C6