Heat Load Calculation Sheet

This document appears to be calculating heating and cooling loads for a building. It includes calculations for outdoor air temperature, room sensible and latent heat, supply and return air flows, solar and transmission gains through walls, roof and glass, and internal heat gains from people, equipment and appliances. The final calculation is for the total or dehumidified heating and cooling load on the building.

Uploaded by

ghazi4u
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
100% found this document useful (1 vote)
3K views

Heat Load Calculation Sheet

This document appears to be calculating heating and cooling loads for a building. It includes calculations for outdoor air temperature, room sensible and latent heat, supply and return air flows, solar and transmission gains through walls, roof and glass, and internal heat gains from people, equipment and appliances. The final calculation is for the total or dehumidified heating and cooling load on the building.

Uploaded by

ghazi4u
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
You are on page 1/ 1

PREPARED BY : NAME OF THE JOB : LOCATION : SPACE USED FOR SIZE = ITEM SQFT X AREA/ QTY GLASS GLASS

GLASS GLASS SKYLIGHT WALL WALL WALL WALL N S E W N S E W 0

VOLTAS LIMITED
Summer Load DATE HT = 0 CU FT FACTOR BTU / HR CONDITIONING OUTDOOR ( OA ) 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 43.00 14.00 0.00 0.00 0.00 X X X X X X X X X X X X X X X X 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.61 0.30 0.00 0.00 1.08 0 ROOM ( RM ) 0 DIFFRENCE 0 0 0 0 0 0 0 0 0 0 ESHF 0 0 Indicated ADP = D Hum Rise X X 0.00 WATTS 0.00 WATTS 1 SQ FT X X X X X SUB TOT 0 Supply 0 cfm 0 Bypass FAN 0 CFM X 0 LATENT HEAT 0.1 B F X EFFECTIVE ROOM SENSIBLE HEAT ( ERSH ) 7.5 % 1.08 0 CFM 0 0 0.68 181 1050 0 SQ FT X 0.01 SUB TOTAL 0 0 0 0.68 0 0 1.08 0.68 0 2545 0 0 BTU'S/HR TR 0 0.00 5 % ROOM LATENT HEAT ( RLH ) 0 0 0 0.00 CFM SA #DIV/0! CFMDA #DIV/0! 1.08 x #DIV/0! 0 RSH F Otd = #DIV/0! 5 % ROOM SENSIBLE HEAT ( RSH ) 3.4 3.4 0 SUB TOT 269.00 0 CFM DA 0 0 0 Outlet 0 temp 0 diff 1.08 x 0 RSH 0 CFM DA = #DIV/0! 1.08 x 1.8 0 ERSH 1.8 F D Hum Rise 0.00 0 ERSH 0 ERTH Selected ADP = -2 = INFIL 0 TRATION VENTI LATION 1 PEOPLE X 0 SQ FT X AIR CHANGE 0 0 DB CFM/PERSON = CFM / SQFT = CFM / VENTILATION = SAY 0.00 0 0 OUTDOOR AIR XXX XXX WB 0 0 SELECTED ROOM CONDITIONS DB WB % RH SUN-GAIN/ TEMP.DIFF. 20.08.03 ESTIMATED TIME 1600 HRS LATITUDE : 22.8 DEG. DP GR / LB

SOLAR GAIN - GLASS 0.00 SQ FT X 0.00 SQ FT X 0.00 SQ FT X 0.00 SQ FT X 0.00 SQ FT X 0.00 SQ FT X 0.00 SQ FT X 0.00 SQ FT X 0.00 SQ FT X 0.00 SQ FT X 0.00 SQ FT X 0.00 SQ FT X 0.00 SQ FT X 0.00 SQ FT X 0.00 SQ FT X 0.00 CFM INTERNAL HEAT PEOPLE POWER LIGHTS COMPUTER APPLIANCES PANTRY APPLIANCES] STORAGE SAFETY FACTOR SUPPLY DUCT HEAT GAIN OUT AIR 0 NOS X

SOLAR & TRANS GAIN - WALLS & ROOF

ROOF-SUN ROOF-SHADED ALL GLASS VGSP PARTITION CEILING FLOOR INFILTRATION

TRANS GAIN - EXCEPT WALLS & ROOF

#DIV/0!

INFILTRATION PEOPLE STEAM APPLIANCES ADD HEAT GAINS VAPOR TRANS SAFETY FACTOR SUPPLY DUCT LEAKAGE LOSS OUT AIR 0 CFM X 1 0

CFM X X LB/HR X

GR/LB X

0 GR / LB X

0.1 B F X

EFFECTIVE ROOM LATENT HEAT ( ERLH ) EFFECTIVE ROOM TOTAL HEAT ( ERTH ) OUT DOOR AIR SENSIBLE LATENT RETURN DUCT DUCT HEAT GAIN 1% RSH 0 0 CFM X CFM X 0 F X (1 RETURN DUCT 0.1 BF ) X 0.1 BF ) X 1% RSH HP X 1% GTH 0 GR/LB X (1-

LEAKAGE GAIN

RETURN DUCT OR BLOW THROUGH FAN PUMP HP 2 % GTH

GRAND TOTAL HEAT (GTH) OR DEHUMIFIED LOAD

PIPING HEAT GAIN HEATING LOAD HEATING LOAD