0% found this document useful (0 votes)
513 views

Mita Codes

This document provides error codes and descriptions for various Mita copier models. It lists the error codes and brief descriptions of the issues they represent for models including Mita 1001, 111, 113, 114, 1205, 1256, 1257, 1355, 1415, 142RE, 1435, 1455, 152Z, 1560, 1605, 1656, 1685, 1655, 1755, 1785, 1856, 2055, 2105, 211, 213, 213RE, 2254, 2255, 2285 and 2355. Common error codes represent problems with items like paper feeding, driving, scanning, lenses, coronas, heating and memory.

Uploaded by

Amer Rafique
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOC, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
513 views

Mita Codes

This document provides error codes and descriptions for various Mita copier models. It lists the error codes and brief descriptions of the issues they represent for models including Mita 1001, 111, 113, 114, 1205, 1256, 1257, 1355, 1415, 142RE, 1435, 1455, 152Z, 1560, 1605, 1656, 1685, 1655, 1755, 1785, 1856, 2055, 2105, 211, 213, 213RE, 2254, 2255, 2285 and 2355. Common error codes represent problems with items like paper feeding, driving, scanning, lenses, coronas, heating and memory.

Uploaded by

Amer Rafique
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOC, PDF, TXT or read online on Scribd
You are on page 1/ 25

Mita 1001

C1 C3 C6 PF Paper feed problem Scanner problem Heat problem C6 more than 6 times

Mita 111, 111C, 113


C1 C5 C6 C7 OP Drive Charge corona Transfer/separator corona Heat Toner hopper lid

Mita 114
C2 C3 C5 C6 Main drive Scan Corona Heat

Mita 1205
C3 C6 Scan Fuser

Mita 1256
AP C01 C02 C21 C30 C40 C61 C63 C64 C72 C73 C74 CC50. Toner being mixed Memory problem. Main board or simulation 70 required EEPROM or main board Drive problem (CC50/1256) Scan Lens drive Fuser problem. No heat or open circuit Fuser thermistor open Fuser thermistor. Short or high fuser temperature 1256 drum thermistor open 1256 drum thermistor shorted CC50/1256 Developer unit fuse. May have to replace developer unit. Problem at

setup C74 C75 C75 C76 J01 J02 J03 OF OP PE/PF U1 Ub Uc 1257 Developer thermistor CC50/1256 Drum unit switch problem or drum setup problem 1257 developer thermistor May not apply to CC50 or 1256, except if metric. Waste toner full. Reset with simulation 78 Feed jam Drum or fuser area jam Jam 1256 drum & developer units must be replaced Front door open No paper, no paper feed problem Total counter CC50. Old developer unit and new drum. Can be reset by replacing the fuse, or by turning the drum one full revolution CC50. New developer unit and old drum. On rear of drum is drum lock. Inside the opening is a white plastic that snaps down after the unit is installed. Remove this rear cover and snap the white plastic blocker back up Toner or developer not installed properly

UF

Mita 1257
AP C01 C02 C21 C30 C40 C61 C63 C64 C72 C73 C74 C74 C75 C75 C76 J01 J02 J03 OF OP CC50. Toner being mixed Memory problem. Main board or simulation 70 required EEPROM or main board Drive problem (CC50/1256) Scan Lens drive Fuser problem. No heat or open circuit Fuser thermistor open Fuser thermistor. Short or high fuser temperature 1256 drum thermistor open 1256 drum thermistor shorted CC50/1256 Developer unit fuse. May have to replace developer unit. Problem at setup 1257 Developer thermistor CC50/1256 Drum unit switch problem or drum setup problem 1257 developer thermistor May not apply to CC50 or 1256, except if metric. Waste toner full. Reset with simulation 78 Feed jam Drum or fuser area jam Jam 1256 drum & developer units must be replaced Front door open

PE/PF U1 Ub Uc

No paper, no paper feed problem Total counter CC50. Old developer unit and new drum. Can be reset by replacing the fuse, or by turning the drum one full revolution CC50. New developer unit and old drum. On rear of drum is drum lock. Inside the opening is a white plastic that snaps down after the unit is installed. Remove this rear cover and snap the white plastic blocker back up Toner or developer not installed properly

UF

Mita 1355
AP C01 C02 C21 C30 C40 C61 C63 C64 C72 C73 C74 C75 C76 J01 J02 J03 OF OP PE/PF U1 Ub Uc Toner being mixed Memory problem. Main board or simulation 70 required EEPROM or main board Drive problem Scan, motor, switch Lens drive Fuser problem. No heat or open circuit Fuser thermistor open Fuser thermistor open Drum thermistor open. Blank lamps Drum thermistor shorted Developer thermistor Drum unit switch problem or drum setup problem Waste toner full, reset with simulation 78 Feed jam Drum or fuser area jam Jam Drum & developer units must be replaced (entire process unit) Front door open No paper or paper feed problem Total counter Old developer unit and new drum. Might be upset by replacing the fuse, or by turning the drum through one full revolution New developer unit and old drum. On rear drum is a lock. Inside the opening is a white plastic that snaps down after the unit is installed. Remove this rear cover and snap the white plastic blocker back up Toner or developer not installed properly. Bad toner sensor

UF

Mita 1415
C3 C6 PE Scan problem Fuser problem. Temperature too low, too high, open thermistor. Heat lamp, thermofuse, thermistor, etc Paper empty

Mita 142RE
C1 C2 C5 C6 C7 Drive Optics Main corona Transfer/separator corona Heat, thermistor, thermofuse

Mita 1435
C01 C30 C31 C32 C40 C5 C61 C62 C63 C64 C73 PE Battery or main board. Simulation 70 might clear Scan problem Scan problem Scan reverse problem Lens motor Lamp Problem Low fuser temperature. Heat lamp, thermofuse Low fuser temperature Fuser thermistor High fuser temperature. Triac, pinched wire Shorted DV unit thermistor Paper empty

Mita 1455
C01 C30 C31 C32 C40 C61 C62 C63 C64 C73 PE Battery or main board. Simulation 70 might clear Scan problem Scan problem Scan reverse problem Lens motor Low fuser temperature. Heat lamp, thermofuse Low fuser temperature Fuser thermistor High fuser temperature. Triac, pinched wire Shorted DV unit thermistor Paper empty

Mita 152Z
C2 C4 Drive section Lens unit

C5 C6

Corona Heater

Mita 1560
C01 C20 C30 C40 C50 C61 C63 C64 C72 C73 C74 C75 C90 J30 J40 J50 PF NVRAM problem Main drive problem Scan problem. Scan sensors, scan motor, belt tension, cable tension, etc Lens motor problem, lens sensor motor Corona problem: Broken wire, shorted blocks, bad corona, high voltage transformer Low fuser temperature. Problem with heat lamp, connections, thermal switch, thermistor or main board Open fuser thermistor Shorted fuser thermistor Open drum thermistor Shorted drum thermistor Open external thermistor Shorted external thermistor Communication problem between copier and ADF Jam in registration area Jam inside machine or fuser Exit jam or fuser jam Paper feed

Mita 1605, 1656, 1685


C01 C20 C30 C31 C32 C33 C40 C50 C51 C60 C61 C62 C63 C70 C71 Memory Drive Scan Scan return Scan motor Scan motor brake Lens motor or mirror motor Charge corona T/S corona High temperature Fuser thermistor No warm up Fuser temperature drops Drum thermistor short Drum thermistor open

Mita 1655
C2 C4 C5 C6 Drive section Lens unit Corona Heater

Mita 1755
AP C01 C21 C31 C41 C42 C51 C52 C61 C63 C64 C72 C73 LED (orange) LED (orange,flashing) LED (red) OP U1 Toner is mixing Memory loss. Use simulation 70 to try and repair. Otherwise must replace main board Main drive problem Scan problem Lens problem Mirror motor problem Charge corona problem Transfer corona problem Low fuser temperature. Lamp, thermofuse, connections, etc Fuser thermistor Fuser thermistor short Drum thermistor Drum thermistor short Paper feed motor problem, or sensor ADF interlock ADF open sensor Front door open of optional cassette is open Key counter

Mita 1785
C2 C3 C4 C5 C6 C0 Drive problem Scan problem Lens problem Coronas Heater problem or only 1 of the 2 front door interlocks switches is actuated Main board problem Run simulation 90. Try power off/on

Mita 1856
AP C01 Toner is feeding Backup memory problem

C03 C05 C07 C21 C22 C23 C24 C31 C41 C42 C51 C52 C61 C63 C64 C72 C73 C81 C82 C83 C84 C91 C92 C93 OP PF U1

Communication problem between main board and scan drive board Ground problem having to do with main board and power relay. Possible short Operation panel thermistor is shorted. Scan motor Main drive problem Side to side registration motor problem in duplex unit Desk drive motor drive problem Paper deck paper conveying motor Scan problem. Scan sensors, scan motor, scan motor drive board, belt tension, cable tension Lens motor problem Scan mirror problem Charge corona problem Transfer/separator corona problem Low fuser temperature Open fuser thermistor Shorted drum thermistor Open drum thermistor Shorted drum thermistor Sorter/stapler feed motor drive problem Sorter/stapler bin shift motor problem Sorter/stapler guide bar motor or guide bar motor sensor Sorter/stapler slide motor problem or sensor problem RADF original feed motor drive problem; motor, pulse sensor, etc RADF belt drive motor drive problem; motor pulse sensor, RADF main board RADF loop motor problem. Loop motor, pulse sensor or RADF main board Cover or door open Paper feed Key counter missing

Mita 2055
AF C00 C01 C2 C20 C21 C3 C4 C40 C41 C5 C6 Original on document feeder placed wrong Battery problem or main board Battery problem or main board Drive problem Drive problem Duplex side to side registration Scan Lens motor Lens motor Mirror motor Coronas Low fuser temperature

C60 C61 C7 C70, C71 U1 UF

High fuser temperature Low fuser temperature DV unit shift problem; color unit dip switch; bad fuser thermofuse DV unit shift problem; color unit dip switch; bad fuser thermofuse Key counter Color unit out

Mita 2105
C1 C2 C3 C5 C6 H0 U1 Paper feed problem (more than 6 times = PF) Drive Scanner problem Corona Heat problem (Fuser) Battery problem Key counter

Mita 211
C1 C2 C3 C4 C5 C6 C7, C8 Scanner home problem/constant jams Motor, clock pulse Scanner problem Exposure lamp Blank lamp Coronas Heater

Mita 213, 213RE


C1 C2 C3 C4 C5 C6 C7 C9 CA CB Scanner home problem, constant jams Motor, clockpulse Scanner problems Exposure lamp Blank lamp Coronas Heater Lens motor Sorter Document feeder

Mita 2254, 2255, 2285


AF C00 C01 C2 C20 C21 C3 C4 C40 C41 C5 C6 C60 C61 C7 C70, C71 U1 UF Original on document feeder placed wrong Battery problem or main board Battery problem or main board Drive problem Drive problem Duplex side to side registration Scan Lens motor Lens motor Mirror motor Coronas Low fuser temperature High fuser temperature Loe fuser temperature DV unit shift problem; color unit dip switch; bad fuser thermofuse DV unit shift problem; color unit dip switch; bad fuser thermofuse Key counter Color unit out

Mita 2355
AP C01 C03 C05 C07 C21 C22 C23 C24 C31 C41 C42 C51 C52 C61 C63 C64 C72 C73 C81 Toner is feeding Backup memory problem Communication problem between main board and scan drive board Ground problem having to do with main board and power relay. Possible short Operation panel thermistor is shorted. Scan motor Main drive problem Side to side registration motor problem in duplex unit Desk drive motor drive problem Paper deck paper conveying motor Scan problem. Scan sensors, scan motor, scan motor drive board, belt tension, cable tension Lens motor problem Scan mirror problem Charge corona problem Transfer/separator corona problem Low fuser temperature Open fuser thermistor Shorted drum thermistor Open drum thermistor Shorted drum thermistor Sorter/stapler feed motor drive problem

C82 C83 C84 C91 C92 C93 OP PF U1

Sorter/stapler bin shift motor problem Sorter/stapler guide bar motor or guide bar motor sensor Sorter/stapler slide motor problem or sensor problem RADF original feed motor drive problem; motor, pulse sensor, etc RADF belt drive motor drive problem; motor pulse sensor, RADF main board RADF loop motor problem. Loop motor, pulse sensor or RADF main board Cover or door open Paper feed Key counter missing

Mita 2555
C1 C2 C20 C31 C40 C50 C51 C60 C61 C62 C63 C70 C01 C02 C05 Back up battery Back up memory Drive Scan (Reset by unplugging) Lens motor Charge corona T/S corona High fuser temp Heat problem or fuser switches Heat problem Low temperature DV selector Back up battery Back up memory Drum thermistor

Mita 2585
C1 C2 C20 C31 C40 C50 C51 C60 C61 C62 C63 C70 Back up battery Back up memory Drive Scan (Reset by unplugging) Lens motor Charge corona T/S corona High fuser temp Heat problem or fuser switches Heat problem Low temperature DV selector

CO1 CO2 CO5

Back up battery Back up memory Drum thermistor

Mita 3055
C01 C03 C21 C22 C23 C31 C41 C51 C52 C61 C63 C64 C65 C71 C72 C73 OP U1 Memory loss, main board, etc. Do simulation 70 Communication problem between main board and scan, or bad scan board or main board Main drive problem Desk side to side registration motor problem Desk drive problem Scan problem Lens problem Charge corona problem Transfer/separator corona problem Fuser problem. SSR Fuser thermistor Fuser temperature too high Fuser temperature too low Developer thermistor Drum thermistor open Drum thermistor short Door open Key counter

Mita 3060
J020 J021 J022 J023 J024 J025 J026 J027 J030 J040 J050 J051 J060 J070 Paper deck horizontal jam Paper deck horizontal jam Paper deck horizontal jam Converging section jam Multiple sheets in feed section Multiple sheets in vertical section Multiple sheets in duplex Multiple sheets before registration Registration or transfer area jam Fuser jam Exit jam Feed shift jam Duplex jam No original fed by RADF

J071 J072 J073 J074 J080 J081 J082 J083 J084 J085 J090 J091

RADF jam RADF belt area jam RADF loop section jam RADF exit jam Copier to sorter jam Sorter feed in jam Jam in non sort bin Non sort exit jam Sorter conveyor jam Sorter exit jam Post sorter jam Stacker hand section jam

Mita 312, 312RE


C1 C2 C3 C4 C5 C6 C7 C8 Drive motor Blanking/cleaning lamp Lens problem Transfer/separator corona Scanner Exposure lamp Thermistor Heat

Mita 313Z, 313ZD


C1 C2 C30 C31 C4 C50 C51 C6 C7 C8 C9 Frequent paper jams Drive motor, clock pulse Scanner problem Exposure lamp Lens motor Corona, transfer/separator Main corona Heater problem Blanking lamp Sorter Document feeder

Mita 3285
30 32 Exposure lamp/XL thermofuse Exposure lamp stays on

C1 C2 C20 C31 C40 C50 C51 C60 C61 C62 C63 C70 CO1 CO2 CO5

Back up battery Back up memory Drive Scan (Reset by unplugging) Lens motor Charge corona T/S corona High fuser temp Heat prob./fuser switch Heat problem Low temperature DV selector Back up battery Back up memory Drum thermistor

Mita 3555, 3585


C01 C02 C05 C20 C21 C30 C31 C40 C41 C50 C51 C60 C61 C62 Battery on main board Battery on main board. May be reset with simulation 70 Drum thermistor. May be reset with simulation 49 Drive problem (pulse sensor, broken gear, bind etc.) Side registration motor or switch problem (duplex area?) Exposure lamp problem or Auto exposure sensor Scan problem Lens motor problem Mirror motor problem Charge corona Transfer/separator corona High fuser temperature, or shorter thermistor Open thermistor Open heater lamp. Not sure if this would light for open thermosfuse or low heat

Mita 3755, 3785


C01, C02 C03 C05 C20 C21 C22 Battery problem. Try simulation 70 Serial communication (main board) Drum thermistor Drive problem Side to side switch in duplex unit Suction fan

C30 C31 C40 C41 C50 C51 C60 C61 C62

Exposure lamp Scan drive Lens drive Mirror drive Charge corona Transfer/separator corona High fuser temperature Open fuser thermistor Low fuser temperature

Mita 4056
C01 C03 C05 C21 C22 C23 C24 C31 C41 C51 C52 C61 C63 C64 C65 C72 C73 C74 C81 C82 C83 C84 C85 C86 C87 C88 C89 C91 C92 C93 Memory problem. Use simulation 70 Communication problem between main board and scan board Auxiliary CPU ROM on main board Main drive problem Duplex side to side registration motor problem Desk drive problem Suction motor Scan problem Lens problem Charge corona short Transfer/separator corona short Fuser problem. Low temperature or open circuit Fuser problem. Thermistor Fuser problem. High temperature Fuser problem. Low temperature or open circuit Drum thermistor open Drum thermistor shorted Developer unit thermistor open Sorter paper feed motor Sorter bin motor Stapler jam Sort bin problem Sorter table motor Sorter bin slide motor Sorter paperweight motor Sorter jogger motor Punch jam RADF feed motor RADF transport motor RADF loop motor

C94 C95

RADF motor running too fast RADF loop motor running too fast

Mita 4085
C2 C30 C31 C4 C50 C51 C60 C61 C7 C8 Drive Scan Exposure lamp Lens motor T/S corona Charge corona Thermistor Heater Blank lamp Sorter

Mita 4086
C01 C03 C05 C21 C22 C23 C24 C31 C41 C51 C52 C61 C63 C64 C65 C72 C73 C74 C81 C82 C83 C84 C85 C86 Memory problem. Use simulation 70 Communication problem between main board and scan board Auxiliary CPU ROM on main board Main drive problem Duplex side to side registration motor problem Desk drive problem Suction motor Scan problem Lens problem Charge corona short Transfer/separator corona short Fuser problem. Low temperature or open circuit Fuser problem. Thermistor Fuser problem. High temperature Fuser problem. Low temperature or open circuit Drum thermistor open Drum thermistor shorted Developer unit thermistor open Sorter paper feed motor Sorter bin motor Stapler jam Sort bin problem Sorter table motor Sorter bin slide motor

C87 C88 C89 C91 C92 C93 C94 C95

Sorter paperweight motor Sorter jogger motor Punch jam RADF feed motor RADF transport motor RADF loop motor RADF motor running too fast RADF loop motor running too fast

Mita 4090
J020 J021 J022 J023 J024 J025 J026 J027 J030 J040 J050 J060 J070 J071 J072 J073 J074 J080 J081 J082 J083 J084 J085 J090 J091 Paper deck horizontal jam Paper deck horizontal jam Paper deck horizontal jam Converging section jam Multiple sheets in feed section Multiple sheets in vertical section Multiple sheets in duplex Multiple sheets before registration Registration or transfer area jam Fuser jam Exit jam Duplex jam No original fed by RADF RADF jam RADF belt area jam RADF loop section jam RADF exit jam Copier to sorter jam Sorter feed in jam Jam in non sort bin Non sort exit jam Sorter conveyor jam Sorter exit jam Post sorter jam Stacker hand section jam

Mita 412
C1 C2 C3 Drive motor Blanking/cleaning lamp Lens problem

C4 C5 C6 C7 C8 C1 C2 C3 C4 C5 C6 C7 C8

Transfer/separator corona Scanner Exposure lamp Thermistor Heat Drive motor Cleaning lamp / blanking lamps Lens Transfer/Separation corona Scanner Exposure lamp Thermistor Heat

Mita 412RE
C1 C2 C3 C4 C5 C6 C7 C8 Drive motor Cleaning lamp / blanking lamps Lens Transfer/Separation corona Scanner Exposure lamp Thermistor Heat

Mita 4555, 4585


C01 C02 C03 C05 C20 C21 C30 C31 C40 C41 C50 C51 C60 C61 C62 Battery Memory Main board or eject board Drum thermistor Drive Duplex side to side registration motor/switches Exposure lamp/thermofuse Scan Lens motor Mirror motor Charge corona Transfer/separator High fuser temperature Fuser thermistor Low temperature

Mita 4655
C01, C02 C03 C05 C20 C21 C22 C30 C31 C40 C41 C50 C51 C60 C61 C62 Battery problem. Try simulation 70 Serial communication (main board) Drum thermistor Drive problem Side to side switch in duplex unit Suction fan Exposure lamp Scan drive Lens drive Mirror drive Charge corona Transfer/separator corona High fuser temperature Open fuser thermistor Low fuser temperature

Mita 4685
C01 C01 C02 C02 C03 C03 C05 C05 C20 C20 C21 C21 C22 C22 C30 C30 C31 Battery problem. Try simulation 70 Backup battery problem With the main switch on, the back up battery voltage is lower than 2.8V Backup memory problem Backup memory is faulty Battery problem. Try simulation 70 Serial communication (main board) Serial communication problem Less than 10 serial data signals are input into and output from the main PCB every 50ms Drum thermistor problem The drum thermistor output voltage is out of the range between 0.3 and 4.7V Drum thermistor Drive problem More than 20 clock pulses are not input to the main PCB within 1 s after the drive motor has turned on Drive problem Side to side switch in duplex unit Side registration motor problem The side registration switch fails to turn on within 8 s after the main switch has turned on Suction fan Paper conveying section fan motor problem CN1-5 on the BM detection PCB remains high Exposure lamp Broken halogen lamp wire The AE sensor output does not exceed 4 V within 300 ms after the HL REMOTE signal has applied to the AVR/Output PCB Scan drive

C40 C40 C41 C41 C50 C50 C51 C51 C60 C60

Lens drive Lens motor problem The lens home position switch fails to turn on within 8 s after the main switch has turned on Mirror motor problem The mirror home position switch fails to turn on within 8 s after the main switch has turned on Mirror drive Main high voltage problem Charge corona Transfer, separation high voltage problem Transfer/separator corona High fuser temperature Abnormally high temperature in the fixing section The fixing unit thermistor output voltage remains less than 0.5 V for longer than 1 s, indicating the fixing temperature rises above 536F Open fuser thermistor Broken fixing unit thermistor wire The fixing unit thermistor wire The fixing unit thermistor output voltage exceeds 4.9 V Broken fixing unit heater wire Fixing temperature does not reach 329 F within 4 minutes after the power relay has turned on Low fuser temperature

C61 C61 C62 C62

Mita 513Z
C01 C02 C03 C04 C05 C06 C07 C21 C22 C31 C32 C35 C36 C37 C41 C51 C52 C53 C55, C56, C58 C61 C62 C63 Toner sensor Drum heater Drum heater Toner sensor Data transfer Board problem Board problem Drive motor/clock pulse PF motor/clock pulse Exposure lamp stays off Exposure lamp stays on Serve motor board/scan motor Serve motor/clock pulse Scan drive Lens motor Charge corona Transfer/sep/corona Bias below 125VDC Drum potential Heater M off Heater M on Heater S off

C64 C65, C66 C71

Heater S on Thermistor Blank lamp/cleaning lamp

Mita 5555
C05 C06 C21 C22 C23 C24 C25 C31 C32 C35 C37 C41 C51 C52 C53 C55 C56 C61 C62 C63 C65 C66 C71 C72 C73 C74 C75 Communication problem between main boards Battery/memory problem Main motor drive Duplex motor drive Paper feed motor drive Duplex motor drive Paper feed motor drive Open exposure lamp Exposure lamp stays on Scan motor or scan motor board or fuser Scan sensor not actuated or not deactuated at proper time Lens motor Charge corona Transfer/separator corona Bias is less then 100 volts Drum surface voltage is too high Drum surface voltage is too low Fuser lamp closest to exit end stays off Fuser lamp closest to drum stays off Fuser lamp(s) stays on High fuser temperature Open fuser thermistor Blank lamp problem Drum thermistor shorted Drum thermistor open High DV unit temperature or shorted DV thermistor Open DV thermistor

Mita 5585
C05 C06 C21 C22 C23 C24 Communication problem between main boards Battery/memory problem Main motor drive Duplex motor drive Paper feed motor drive Duplex motor drive

C25 C31 C32 C35 C37 C41 C51 C52 C53 C55 C56 C61 C62 C63 C65 C66 C71 C72 C73 C74 C75

Paper feed motor drive Open exposure lamp Exposure lamp stays on Scan motor or scan motor board or fuser Scan sensor not actuated or not deactuated at proper time Lens motor Charge corona Transfer/separator corona Bias is less then 100 volts Drum surface voltage is too high Drum surface voltage is too low Fuser lamp closest to exit end stays off Fuser lamp closest to drum stays off Fuser lamp(s) stays on High fuser temperature Open fuser thermistor Blank lamp problem Drum thermistor shorted Drum thermistor open High DV unit temperature or shorted DV thermistor Open DV thermistor

Mita 5685
C05 C06 C07 C21 C22 C23 C24 C25 C26 C31 C32 C35 C41 C51 C52 C53 C54 C55 Circuit board problem Battery problem. Try simulation 79 Ram problem Drive problem-upper section Drive problem-lower section Paper feed motor Duplex side registration sensor (jogger) or motor Large capacity cassette Fuser motor Open exposure lamp Exposure lamp won't shut off Scan motor scan board Lens motor Charge corona Transfer/separator corona Bias problem Drum potential sensor Drum potential sensor

C56 C62 C63 C65 C66 C71 C72 C73 C74 C75

Drum potential sensor or no charge Fuser problem. Low heat. Lamp (there are 2) or thermofuse Fuser lamps won't shut off High fuser temperature or shorted fuser thermistor Open fuser thermistor Blank lamp problem Shorted drum thermistor Shorted DV unit thermistor Shorted DV unit thermistor Open DV unit thermistor

Mita 6090
C010 C030 Backup memory problem The specified data was not written into NVRAM Serial communication problem (main PCB problem) Communication procedure fails to complete within 200 ms in any block. Nine consecutive reception errors occur in one block Serial communication problem (operation unit PCB problem) Communication procedure fails to complete within 200 ms in any block. Nine consecutive reception errors occur in one block Serial communication problem (servo motor PCB problem) serial communication between the main PCB and the servo motor PCB fails five times consecutively Serial communication problem (RDH main PCB problem) Serial communication between the copier main PCB and the RDH main PCB fails five times consecutively Halogen lamp problem While the scanner motor rotates in forward direction because of the lamp on signal, the HLISENS input signal fails to go low. The HLISENS input signal fails to go low during exposure correction Paper conveying motor problem No en r signal is received 250 ms after the paper conveying motor on signal has been emitted Side registration motor problem The side registration home position switch fails to turn on within 5 s after the main switch has been turned on Fewer than five pulses are generated by the drum motor en r in 1 s after the drum motor on signal has been emitted Paper deck motor problem The paper deck level switch or the home position switch fails to turn on within 20 s after the paper deck motor on signal has been emitted Upper drawer motor problem The upper drawer level switch or the position switch fails to turn on within 8 s Middle drawer motor problem The middle drawer level switch or the position switch fails to turn on within 8 s after the middle drawer motor on signal has been emitted Lower drawer motor problem The lower drawer level switch or the position switch fails to turn on within 8 s after the middle drawer motor on signal has been emitted Scanner motor problem (main PCB problem) The home position switch fails to turn on within 4 s after the scanner motor reverse signal has been emitted Scanner motor problem (servo motor PCB problem) No signal is generated by the en r 20ms after the scanner motor reverse signal has been emitted Scanner motor problem3523 or more SM forward pulses are received after the scanner motor has started to rotate forward. The scanner motor speed exceeds the specified level The home position switch fails to turn on within 4 s after the SM HP signal has gone low

C031

C032 C033 C110

C210 C220 C230 C240 C250 C251 C252 C310 C311 C312

C313

C314

Servo motor CPU problem With the scanner motor forward signal on, the average motor speed exceeds 900 mm/s in any 60 ms (excluding the first 20 ms after the signal is emitted;or with the scanner motor reverse signal on, the average motor speed exceeds 1600 mm/s in any 60 ms excluding the first 60 ms after the signal is emitted Lens motor problem The lens home position switch fails to turn on within 12 s after the lens motor home signal has been emitted Main high voltage problem The short detection signal is generated by the main charger high-voltage PCB for 5 s Transfer high voltage problem The transfer high voltage short detection signal is generated by the transfer charger high-voltage PCB for 5 s Separation high-voltage problem The separation high voltage short detection signal is generated by the transfer charger high-voltage PCB for 5 s Pre-transfer high-voltage problem The pre-transfer short detection signal is generated by the pretransfer charger high-voltage PCB for 5 s Bias problem-The short detection signal is generated by the bias PCB for 5 s Potential sensor problem During initial potential sensor calibration, the difference between the sensor outputs when 500 V and 300 V are applied to the drum is zero or negative Potential adjustment problem: max level During initial potential settling, the drum potential cannot be set to the specified level by increasing the primary main charger control signal to its maximum Potential adjustment problem: min. level During initial potential setting, the drum potential cannot be set to the specified level by reducing the primary admin charger control signal to its minimum Exposure adjustment problem: max level Exposure adjustment problem: min level During initial light intensity correction, the potential sensor output cannot be set to the specified level even with the halogen lamp control signal at min Fixing unit heater M wire broken No heater check signal is generated by the noise filter PCB 800 ms after the fixing unit heater S off signal and the fixing unit heater M on signal have been emitted Fixing unit heater S wire broken No heater check signal is generated by the noise filter PCB 800 ms after the fixing unit heater M off signal and the fixing unit heater S on signal have been emitted Fixing unit heats failing to turn off The heater check signal continues to be generated by the noise filter PCB 320 ms after the fixing unit heater M and S off signals have been emitted Fixing unit thermistor wire broken The data generated by the fixing unit thermistor remains at F1H or above for longer than two minutes while fixing unit heaters M and S are on Fixing unit thermistor wire shorted/abnormally high temperature detected Data from the fixing unit thermistor remains at 45H or less for 160 ms or longer Fixing unit thermistor abnormally low temperature detected The signal from the fixing unit thermistor registers 100C or lower during standby or a copying cycle after secondary stabilization Toner sensor problem Data from the toner sensor remains at 14H or less, or F0H or above for 320 ms Drum thermistor wire broken The signal from the drum thermistor remains high for 5s Drum thermistor shorted/abnormally high temperature detected The signal from the drum thermistor remains low for 5 s Drum thermistor abnormally low temperature detected The drum heater remains on at 100% output for 17 minutes with the safety switches on Internal temperature thermistor broken Data from the internal temperature thermistor remains at 0CH or less for 320 ms

C410 C510 C520 C521 C530 C540 C550

C560

C561

C570 C571

C610

C611

C620

C630

C640 C641

C710 C720 C730 C731 C740

C741

External temperature thermistor problem Data from the external temperature thermistor remains at F0H or above (too low a temperature or broken wire) or at 33H or less (too high a temperature or shorted wire) for 320 ms Developing unit thermistor problem Data from the developing unit thermistor remains at F0H or above (too low a temperature or broken wire) or at 33H or less (too high a temperature or shorted wire) for 320 ms Toner cartridge shutter problem The shutter home position switch fails to turn off within 10 s after the toner cartridge a shutter mode on signal has been emitted. The shutter home position switch fails to turn on within 40 s after it has turned off Toner cartridge loading problem The TCPSW1 or TCPSW2 signal falls to be input within 40 s after the toner cartridge loading motor on signal has been emitted Toner hopper problem No signal is input from the toner level detection switch after automatic toner replenishing is completed Sorter feed motor problem A feed motor problem A feed motor jam is detected (with the stapler-sorter attached). The feed motor current exceeds 2 A for 50 ms (with the sorter attached) Sorter feed motor circuit problem No feed motor index signal is detected for 30 ms (with the sorter attached) Sorter bin drive motor problem The sorter bin unit fails to return to the home position during initialization (with the stapler-sorter attached). The sorter shift motor current exceeds 1.2 A for 50 ms (with the sorter attached) Sorter shift motor PCB problem (sorter) No en r signal is detected from the sorter shift motor for 50 ms Sorter table motor problem (stapler-sorter) The sorters stapler table fails to return to the home position during initialization Sorter bin side motor problem (stapler-sorter) The bin fails to return to the sliding home position during initialization. The bin fails to move to the stapling/punching position. The bin fails to return to the sliding home position Sorter paper weight motor problem (stapler-sorter) The sorter paper weight fails to return to the home position during initialization. The sorter paper weight fails to move to the operating position when it should. The sorter paper weight fails to return to the home position after releasing the paper Sorter jog motor problem The jog unit fails to return to the home position during initialization. The job unit fails to move to the standby position when paper is fed Sorter bin upper limit detected (stapler-sorter) The bin upper limit sensor turns on while the sorter bin drive motor drives Sorter bin unit lower limit detected (stapler-sorter) The bin unit lower limit sensor turns on while the sorter bin drive motor drives Sorter punch jam (stapler-sorter) The punch fails to return to the home position during initialization. The punch fails to return to the home position during operation Sorter stapler jam The stapler fails to return to the home position during initialization. The stapler fails to return to the home position during operation. The stapler motor current exceeds 5 A for 30 ms (with the sorter) Sorter stapler motor problem A block signal fails to be input from the home sensor within 100 ms after the stapler motor has turned on. Home signal fails to be input within 250 ms after the block signal has been emitted Sorter shutter motor problem (auto stacker) The sorter shutter fails to close during initialization. The sorter shutter fails to close during initialization. The sorter shutter fails to open during operation. The sorter shutter fails to close during operation Hand table motor problem (auto stacker) The hand table fails to return to the home position during initialization. The hand table fails to move to the standby position during operation. The hand unit fails to move to the standby position during operation. The hand unit fails to return to the home position for paper ejection Hand unit drive motor problem (auto stacker) The hand unit fails to return to the home position during initialization. The hand table fails to return to the home position during initialization. The hand table fails to move to the standby position during operation. The hand unit fails to move to the standby position during operation. The hand unit fails to return to the home position for paper ejection

C750

C760

C761 C762 C810

C811 C820

C821 C830 C831

C832

C833 C840 C841 C850 C851

C852

C860

C861

C862

C863 C910 C920

Stapler-sorter-stacker communication problem An error occurs during serial communication between the stapler-sorter and the auto-stacker RDH original feed motor problem No pulse is generated by the pulse sensor for 800 ms or longer while the RDH original feed motor is rotating RDH original conveying motor problem No pulses are generated by the pulse sensor for 800 ms or longer while the RDH original conveying motor is rotating. No pulses are generated by the pulse sensor for 800 ms or longer while the RDH original conveying motor is rotating RDH original eject motor problem No pulse is generated by the pulse sensor for 800 ms or longer while the RDH original eject motor is rotating RDH original transfer motor problem If the original transfer plate home position switch fails to turn on during the 2.5 s when the original transfer motor reverses for 2.5 s, which is repeated twice. The home position switch does not turn on after this process RDH original jogging motor problem If the RDH original jogging guide home position switch fails to turn off 1 s or longer after the original jogging motor has turned on

C930 C940

C950

Mita 7085
C05 C06 C07 C21 C22 C23 C24 C25 C26 C31 C32 C35 C41 C51 C52 C53 C54, C55 C56 C62 C63 C65 C66 C71 C72 C73, C74 C75 Circuit board problem Battery problem. Try simulation 79 Ram problem Drive problem-upper section Drive problem-lower section Paper feed motor Duplex side registration sensor (jogger) or motor Large capacity cassette Fuser motor Open exposure lamp Exposure lamp won't shut off Scan motor scan board Lens motor Charge corona Transfer/separator corona Bias problem Drum potential sensor Drum potential sensor or no charge Fuser problem. Low heat. Lamp (there are 2) or thermofuse Fuser lamps won't shut off High fuser temperature or shorted fuser thermistor Open fuser thermistor Blank lamp problem Shorted drum thermistor Shorted DV unit thermistor Open DV unit thermistor